Our energy at your service GENERATION & NETWORK Transformer Protection IED NPT916 • Predefined or custom connection group selection • 2nd and 5th harmonic blocking • Automatic verification of connection group and nominal value settings • Through fault and overloading statistics for preventive maintenance The optimal management of electrical power systems is based in particular on the reliability, availability and communication skills of protection, measurement and automation devices. NPT916 is a transformer protection IED with sophisticated and easy to use differential protection function. The NPT916 transformer protection IED provides for both low and high side overcurrent, earth-fault, negative sequence and two independent restricted earth-fault instances. The NPT916 can be applied for generator and motor differential protection as well. The NPT916 communicates using various protocols including IEC 61850 substation communication standard. ANSI CODES

ANSI CODES O gy your e - CEE · PDF fileO gy your e GENERATION & NETWORK Transformer Protection IED NPT916 • Predefined or custom connection group selection • 2nd and 5th harmonic

Embed Size (px)

Citation preview

Our energy at your service

GENERATION & NETWORKTransformer Protection IED

NPT916

• Predefinedorcustomconnectiongroupselection

• 2ndand5thharmonicblocking

• Automaticverificationofconnectiongroupandnominalvaluesettings

• Throughfaultandoverloadingstatisticsforpreventivemaintenance

The optimal management of electrical power systems is based inparticular on the reliability, availability and communication skills ofprotection,measurementandautomationdevices.

NPT916isatransformerprotectionIEDwithsophisticatedandeasytousedifferentialprotectionfunction.TheNPT916transformerprotectionIEDprovidesforbothlowandhighsideovercurrent,earth-fault,negativesequenceand two independent restrictedearth-fault instances.TheNPT916canbeappliedforgeneratorandmotordifferentialprotectionaswell.

TheNPT916communicatesusingvariousprotocolsincludingIEC61850substationcommunicationstandard.

ANSI CODES

A934C

CHARACTERISTICSProtection functions

• 2windingtransformerdifferential[87T]• Lowimpedancerestrictedearthfault/cableenddifferential[87N]

• Transformerthermaloverload[49T]• Three-phaseovercurrent,4stagesINST,DTorIDMT[50/51]

• Earth-fault(sensitive),4stagesINST,DTorIDMT[50/51N(S)]

• Harmonicovercurrent/inrushblocking,4stagesINST,DTorIDMT[50H/51H/68H]

• Currentunbalance/brokenconductor,4stagesINST,DTorIDMT[46R/46L/46]

• Breakerfailureprotection[50BF/52BF]• Arcprotection(option)[50ARC]

Measuring and monitoring• Phaseandresidualcurrents(IL1,IL2,IL3,I01,I02)• CurrentTHDandharmonics(upto31st)• Frequency(f)• Circuitbreakerwear(CBW)• Disturbancerecorder(3.2kHz)• Currenttransformersupervision(CTS),2instances• Tripcircuitsupervision[74TC]

Control• Controllableobjects:5• 8settinggroups

Hardware• Currentinputs:10• Digitalinputs:3(standard)• Outputrelays:5+1(standard)

Options (2 slots)• Digitalinputsoptional:+8percard• Digitaloutputsoptional:+5percard(2cardsmax.)• Arcprotection(12sensors+2xHSO+BI)• 2xmAinput+6-8xRTDinput(2cardsmax.)• Communicationmedia(specifiedbelow)

Event recording• Non-volatiledisturbancerecords:100• Non-volatileeventrecords:10000

Communication media• RJ45Ethernet100Mb(frontstandard)• DoubleLCEthernet100Mb(option)• RS232+serialfibrePP/PG/GP/GG(option)

Communication protocols standard• IEC61850• IEC60870-5-103/101/104• ModbusRTU,ModbusTCP/IP• DNP3.0,DNP3.0overTCP/IP• SPA

Case• H,W,Dwithoutterminal177x127x174mm• H,W,Dwithterminal177x127x189mm(casingheight4U,width¼rack,depth210mm)

• H,Woffrontplate177x127mm• H,Wofcutout160x106mm

SMART9 - integrated softwareOur user friendly SMART9 (Setting, Measurement,Analysis,Recording,Time-saving)configurationsoftwarehelpstheusergetthebestfromNP900seriesrelays.