Upload
others
View
77
Download
0
Embed Size (px)
Citation preview
AnkleFixationSystem™
System Brochure
Transverse
Fibula
Tibia
Tibia/Fibula
FractureAnatomy Implant
Semi-Tubular Plate
Semi-Tubular PlateOblique
Comminuted
Transverse
Vertical
Medial MalleolarPin Plate
4.0mm CannulatedCompression Screw
4.0mm CannulatedCompression Screw
Sidewinder Plate
Ankle Hook Plate
Medial MalleolarPin Plate
Semi-Tubular Plate
4.0mm Cortical ScrewSyndesmosis Injury
Recommended
Ankle Hook Plate
Medial Malleolar Sled
Ankle Hook Plate
Opposite view
Sidewinder Plate™
Double antiglide plate with opposing compression tabs eliminate need for lag screws
Typical uses:• Short oblique fibula fractures
Sizes: Lengths:6 Hole 69 mm7 Hole 76 mm
Left & Right PlatesNarrow, Medium & Wide tab widths Locking option available
IMPLANTS
2
Position plate Insert screws Crimp tabs Final fixation
Screw holes accomodate:- Locking/non-locking cortical screws- Cancellous screws- Syndesmosis screws- Bioabsorbable syndesmosis screw
Triple lead locking threads for ease of insertion
Compression tab for compression and anti-glide effect
Slotted hole for use with Xpander to distract or compress(reference pg. 9, 10)
3
Ankle Hook Plate™
Contoured plate with intramedullary tines for enhanced rotational stability
Typical uses:• Lateral and medial malleolus fractures
Locking option available* Special Order
Sizes: Lengths:4 Hole 57 mm6 Hole 73 mm8 Hole 88 mm10 Hole* 118 mm12 Hole* 136 mm
Drill Seat hooks Compress fracture Final fixation
Slotted hole for use with Xpander to distract or compress
Triple lead locking threadsfor ease of insertion
Intramedullary tines for increased rotational stabilty
Offset screw holes to reduce stress risers
Screw holes accomodate:- Locking/non-locking cortical screws- Cancellous Screws- Syndesmosis Screws- Bioabsorbable Syndesmosis Screws
4
Medial Malleolar Sled™
Simple one-piece tension band combines surface and intramedullary fixation
Typical uses:• Medial malleolus fractures• Fixation of medial malleolar osteotomies
* Special Order
Lengths (L):MMSLED-35 (30 mm) MMSLED-42 (37 mm) MMSLED-60 (51 mm) *
L
Drill Seat Sled Apply washer Final fixation
2mm wire reduces chance of iatrogenic fracture on small distal fragments
Screw + WasherProvides Compression
Offset cannulated sled legs aid insertion
5
Medial Malleolar Pin Plate™
Locking pin plate provides buttressing support with intramedullary fixation
Typical uses:• Transverse and vertical shear fractures of the distal tibia
Sizes: Lengths:3 Hole* 47 mm4 Hole* 53 mm
* Special Order
Drill Impact Compress Final fixation
Intramedullary 1.6mm U-wire reduces iatrogenic fractures on small distal fragments
Slotted hole for use with Xpander to distract or compress
U-Pin locks into slightlyundersized holes on plate
6
Sizes: Lengths:6 Hole 67 mm8 Hole 85 mm10 Hole 103 mm12 Hole* 150 mm15 Hole* 178 mm
Semi-Tubular PlateContoured plate with offset screw holes for greater load support
Typical uses:• Distal / proximal long bone fixation
4.0 Cortical ScrewLow-profile, self-tapping screw for enhanced bone purchase
Typical uses:• Syndesmosis fixation• Posteriormalleolarfixation
Lengths:35, 40, 45, 50, 55, 60 mm
Locking option available* Special Order
4.0 Cannulated Compression ScrewLow-profile, self-drilling, self-tapping screw for fracture fixation
Typical uses:• Distal tibial metaphyseal fractures
Lengths:35, 40, 45, 50, 55, 60 mm
7
08-24 mm(2mm increments)
2.3 mm 2.3 mm2.3 mm
3.2 mm 3.2 mm n/a n/a
n/a n/a n/a
n/a n/a n/a n/a
4.0 mm
AFS-CSINK AFS-CSINK
AFSW
2.5 mmHEX CANNULATED2.5 mm HEX 2.5 mm HEX 2.5 mm HEX 2.5 mm HEX
3.2 mm(4.0mm overdrill)
3.2CL mm(Cannulated Long)
08-24 mm(2mm increments)
10-40 mm(2mm increments)
35-60mm(5mm increments)
35-60mm(5mm increments)Lengths
Drivers
Washer
Note: The 1.6mm k-wires are used with the CCS4.0-XX.
Drill Bits
Taps
Countersink
Guides
SCrewS
GUIDE-2.30/3.20 GUIDE-LCBS2.3 GUIDE-2.30/3.20 MGUIDE-4.0 MGUIDE-4.0
3.2 mm corticalHEX3.2-XX
3.2 mm locking corticalLCBS3.2-XX
3.8 mm cancellousCAB3.8-XX
4.0 mm corticalHEX4.0-XX
4.0 mm cannulatedcompression screw
CCS4.0-XX
TOOLS
8
Guides
Drill Guide 2.30/3.20 mm GUIDE-2.30/3.20
Drill Guide for 3.2 mm Locking ScrewGUIDE-LCBS2.3
HookPlateDrillGuideHOOK-GUIDE
Medial Malleolar Sled GuideMMSLED-GUIDE
Medial Malleolar Sled Washer GuideMMSLEDW-GUIDE
MedialMalleolarPinPlateGuideMPP-GUIDE
Drill Guide for 4.0mm ScrewMGUIDE-4.0
PlateBenderBNDR
Modular HandleMODHNDL
Quick HandleQUICK-HNDL
Ratchet HandleRATCH-HNDL
Large Depth GaugeGAUGE-L
Wire GaugeWIRE-GAUGE
ExpanderXPANDER
ImpactorSLED-IMPACTR
CountersinkAFS-CSINK
PegGuideExtenderPEG-XTNDR
Medial MalleolarPinPlateWireInserterMPP-INSERTR
CrimperCRIMPR
ClampSWBC
General Tools
Gauges
1
2
12
1
1
2
22
1
2
122
exPANder TOOL - COMPreSSION
9
Insert hook in hole away from fracture Squeeze handle; tighten screw Final fixation
1
2
12
1
1
2
22
1
2
122
exPANder TOOL - dISTrACTION
10
Insert hook in hole close to fracture Squeeze handle; tighten screw Final fixation
TriMed, Inc. | 27533 Avenue Hopkins | Santa Clarita, California 91355T. 800-633-7221 T. 661-255-7406 F. 661-254-8485
www.trimedortho.com
© 2014 TriMed, Inc. All rights reserved.
Patent Coverage: TriMed, Inc. products are covered by patents issued in the U.S. and in foreign jurisdictions.
The presently issued U.S. patents are: 5,709,682; 5,718,704; 5,931,839; 5,941,878; 6,077,266; 6,113,603; 7,037,308; 7,044,951; 7,195,633; 7,267,678; 7,540,874; 7,749,257; 7,811,286.
878 - 1 01/14The technique presented is one suggested surgical technique. The decision to use a specific implant and the surgical technique must be based on sound medical judgment by the surgeon that takes into consideration factors such as the circumstances and configuration of the injury.