S W I T C H B O A R D I N S T R U M E N T S
............................................................................................................................................................................2
S W I T C H B O A R D I N S T R U M E N T S
RUDDER METERThis series of back-lit meters provides a continuous analog indication of the rudder position of a boat or ship based on an input signal from a position transducer.
AB/DB40-METAL CASEThe industry standard for 4 1/4” switchboard instruments. Featuresinclude weathertight construction, and interchangeable scales, andoptional illumination for ammeters and voltmeters.
AB/DB16-8 3/4” CASEThis instrument is easily readable from distances over 30 feet. Availablein the same ratings as the AB/DB40.
AB/DB14-HIGH SHOCKAB/DB14 Ammeters and Voltmeters are supplied in accordance with mili-tary specifications MIL-S-901 and MIL-M-16034. Primary application is forhigh shock conditions such as shipboard control panels.
AB/DB40-PLASTIC CASELow-cost plastic case Ammeters and Voltmeters that meet ANSI C39.1.These meters offer the same high quality and realibility as the AB/DB40at a substantial price difference.
2180-MINIATURE CASEType 2180 switchboard instruments offer 250° scale resolution and 1.5%full scale accuracy. The 3 1/4” face takes up less panel space than con-ventional switchboard meters.
180-EDGEWISEType 180 meters are available in horizontal and vertical mounting con-figurations. Internal illumination is available as an option.
DUAL-VUE METERSThe DualVue series of switchboard meters accepts inputs of AC or DCvoltage or current. They provide a convenient combination of an analogscale and digital readout in a rugged switchboard meter case with IP54rated cover.
............................................................................................................................................................................3
S W I T C H B O A R D I N S T R U M E N T S
ADDITIONAL YOKOGAWA PRODUCTS
PANEL METERS
Yokogawa has the broadest line of panel meters available today. The
New Big Look, Horizon and Stylist series of meters are RoHS compliant.
UL and IP54 splash resistant models are available. Request catalog
250260PM-01E-A for more information.
POWER SERIES PLUS
The POWER SERIESPlus digital switchboard meter was developed by
Yokogawa to provide our customers with a versatil AC digital power
meter. Requested catalog PSP-03B for more information.
CLAMP-ON POWER METERS
Yokogawa CW240 and CW120 Clamp-on power meters provide conve-
nient tools for monitoring power quality and energy consumption. A
powerful data analysis software program is also available. Request cat-
alog CW-E for more information.
LOOP POWERED INDICATORS
Yokogawa provides many styles of analog and digital loop powered
indicators. Request catalog BULOOP-01E-A for more information.
PR300 POWER & ENERGY METER
Yokogawa POWERCERT PR300 power & energy Meter provides a panel-
mounted power and energy consumption monitoring meter with a
large three-line display, RS-485 (Modbus/PC link) and Ethernet commu-
nication. Request catalog BU77C01A02-E for more information.
CONTRACT MANUFACTURING
Yokogawa Corporation of America is a turnkey operation for both
electrical and mechanical products. Your product can be produced at
the highest level of quality and at a competitive price, with delivery to
you or your customer anywhere in the world. Request the Contract
Manufacturing catalog for more information.
............................................................................................................................................................................4
S W I T C H B O A R D I N S T R U M E N T S
ADDITIONAL YOKOGAWA PRODUCTS
XL120 PORTABLE DATA ACQUISITION
Yokogawa Datum-Y™ Portable Data Station provides a compact Data
logger with high noise immunity and powerful communication fea-
tures. Request catalog XL120-E for more information.
CA150 CALIBRATORS
Yokogawa CA150 Handy Calibrator is a multi-functional hand-held cali-
brator with high accuracy that can measure and perform as a source
simultaneously. Request catalog CA150-E for more information.
INSULATION TESTERS
Yokogawa insulation testers are battery powered and available in sin-
gle and multiple range models in analog or digital versions. Request
catalog MY-E for more information.
800PLUS DIGITAL PANEL METERS & COUNTERSYokogawa Corporation of America 800Plus series provides universal digi-tal panel meters for measurement and display of electrical, thermocou-ple, RTD, strain gauge, load cell and process signals and digital coun-ters for measurement of frequency, period, rate, total integration,square root, quadrature and more. Request catalog 800SG-01C formore information.
POWER TRANSDUCERS
Yokogawa Juxta Power Transducers are UL recognized and enclosed in
a rugged metal case. Both 0.2% and 0.5% models are available.
Request catalog BU-JAC-07E for more information.
DIGITAL MULTIMETERS
Yokogawa digital multimeters are available in 3.5 and 4.5 digit hand-
held models. TY700 Series has a DC voltage measurement accuracy of
0.02%. Request catalog DMM-E for more information.
............................................................................................................................................................................5
S W I T C H B O A R D I N S T R U M E N T S
Digits 1, 2, & 3 Type101-TB-AB/DB14103-TB-AB/DB40106-P&J-AB40 Synch.120-P&J-AB16 Synch.121-TB-AB/DB16123-D-V Red LED124-D-V Green LEDD-V= Dual-Vue126-Red back-lit 103127-White back-lit 103
Digits 12, 13 & 14-Spcl UnitsWhen used, these denoteunique models. Refer tofactory for details. ForWattmeters & Varmeters,see pages 18-23.
Digits 12, 13 & 14 for models**126:R06=6VDCR12=12VDCR24=24-28VDCR48=48VDC
127:W06=6VDCW12=12VDCW24=24VDCW48=48VDC**not used if otherunique features areincluded.
*Digit 11 - FactoryStyle No.For factory use.Not used for models123,124, or 125
Digit 11 formodels123, 124, 1251=120VAC2=240VAC3=125VDC4=24VDC5=48VDC
Digits 9 & 10 - ScaleEx: FA = 0–1mA
FX = 0–5mA(see note 2)
Digits 7 & 8 - Elec. Rtg.Ex: LA = 1A
LE = 2ALS = 5A
(see note 2)
Digit 6 Mechanical Features1-Zero left, black cover2-Zero center, black cover3-Zero left, gray cover4-Zero center, gray cover5-Zero left, antiglare, black cover6-Zero center, antiglare, black cover
NOTES:1. This tabulation is not all inclusive, to be
used for defining cat. nos. only2. For watt & var cat. nos. digits 7–10 & 12–14
designate rating-cal watts-scale & legendinformation
3. TB = taut band movement4. P&J = pivot & jewel movement5. “/P” suffix denotes plastic case
Low Cal Watts, Zero Center6. Back-lit is available in red or white on
models 103 01, 02, 07, 11, 12 and 16
Digits 4 & 5 Measured Qty.01-DC Volts02-AC Volts07 Voltmeter (expanded scale)11-DC Amps12-DC Millivolts13-AC Amps15-AC voltmeter (rectifier type)19-Supp. Zero21-2W1P Watts 1 EL22-3W3P Watts 2 EL25-4W3P Watts 21⁄2 EL28-3W3P Vars (cross phase) 2 EL29-4W3P Vars (cross phase) 21⁄2 EL31-2W1P Vars 1 EL32-3W3P Vars (external phase shifter) 2 EL34-4W3P Vars (external phase shifter) 21⁄2 EL37-Freq. Meter40-Power Factor 3W3P & 4W3P (balanced)41-Power Factor 2W1P45-Synchroscope46-Power Factor-3W3P (unbalanced)47-Power Factor-4W3P (unbalanced)50-Temp. Ind.55-DC Voltmeter (ground detector type)62-DC Tach. Ind.63-AC Tach. Ind.70-2WIP Watts 1 EL71-3W3P Watts 2 EL73-4W3P Watts 2 1⁄2 EL74-4W3P Vars (cross phase) 21⁄2 EL76-2W1P Vars 1 EL77-3W3P Vars (for use w/external phase shifter) 2 EL79-4W3P Vars (for use w/external phase shifter) 21⁄2 EL81-3W3P Vars 2 EL (cross PH)
Key to AB/DB Switchboard Numbering System (See Notes)
1 XX XX 7* XXX103 01
How to Order —Specify the following:1. Complete catalog number, or;
2. Provide significant portion of catalog number with worddescription for differences (e.g. ”Similar to 103111FAFA,except scale 0-100 kilovars”), or
3. Provide word description including the following information:
Type: AB/DB-14, 16, or 40Rating (Input):.....................Amperes AC or DC .....................Volts AC or DC ..........................................................................Frequency: 60 Hz, 50 Hz, 400 Hz........................................HzScale: Min. Value - Max. Value, Zero left,Zero-center or offset zeroLegend: Specify words and/or symbols exactlyPotential Transformer Ratio: ...............................to 120 voltsor ........................................to ...........................................voltsCurrent Transformer Ratio: ...............................to 5 amperesor ........................................to.....................................amperesCircuit: 2-wire/single-phase, 3-wire/3 phase.3-phase/4-wire.................................................................otherExternal Devices; phase Shifting transformers, shuntstransducers, etc.........................................................................
Other Options:..........................................................................Special features ........................................................................
Shipping & Storage Weights*AD/DB-40 AD/DB-16
Instrument Net Ship Net Ship(lbs) (kg) (lbs) (kg) (lbs) (kg) (lbs) (kg)
DC-A/V 1.5 .70 2.4 1.1 3.0 1.4 5.0 2.2
V 1.7 .79 2.7 1.2 3.4 1.5 5.0 2.2
A 1.8 .84 2.7 1.2 3.4 1.5 5.0 2.3
1ø 2.8 1.3 3.6 1.7 4.4 2.0 6.0 2.8
3ø3W 3.0 1.4 3.9 1.8 4.6 2.1 6.3 2.93ø4W
Power Factor 2.0 .95 3.0 1.4 3.6 1.7 5.3 2.4
Frequency 1.8 .82 2.7 1.2 3.3 1.5 5.0 2.3
Temperature 2.0 .95 3.0 1.4 3.6 1.7 5.3 2.4
Tachometer 1.6 .80 2.7 1.2 3.3 1.5 5.0 2.3
Synchroscope 1.7 .77 2.0 .91 3.1 1.4 4.0 1.8
*Subtract 0.5 lbs. for plastic case amp & volt.
Approximate Package Size in Inches / Centimeters
All AB/DB(Except AB-/DB-16)............................................................................6 x 6 x 11 / 15 x 15 x 28Shipping.............................................................................................7 x 7 x 13 / 18 x 18 x 33
AB-/DB-16 ...........................................................................................10 x 10 x 11 / 25 x 25 x 28Shipping.........................................................................................11 x 11 x 13 / 28 x 28 x 33
AC
WATT/VAR
............................................................................................................................................................................6
S W I T C H B O A R D I N S T R U M E N T S
Model Type AB/DB40 AB/DB40 AB/DB16 Dual-Vue AB40 Hour AB/DB14 T/180 T/2180Case style 41⁄4” Metal 41⁄4” Plastic 83⁄4” 4 1/4” Metal Meters High-shock 6” Edgewise Mini-swbd.
woleb stnetnoc eeSwoleb snoitacificeps lareneg BD/BA eeSInput ratingAC Milliamperes X X X N/A N/A X X XAC Amperes X X X X N/A X X XAC Voltage X X X X X X X XDC Microamperes X X X N/A N/A X X XDC Milliamperes X X X N/A N/A X X XDC Amperes X X X X N/A X X XDC Millivolts X X X N/A N/A X X XDC Voltage X X X X N/A X X N/AFrequency X * X N/A N/A * * XAC Watts X * X N/A N/A * * *AC VARS X * X N/A N/A * * *Power Factor X * X N/A N/A * * XRTD Temperature X * X N/A N/A * * *AC Synchroscope X N/A X N/A N/A N/A N/A N/ARPM Indicator X X X N/A N/A X X XProcess indicator X X X N/A N/A X X XGround detector X X X N/A N/A N/A X XBack-lit X N/A N/A N/A N/A N/A N/A N/A
AB/DB Switchboard specifications in accordance with ANSI C39.1
Accuracy: ±1.0% of full scale basic accuracy class.Specific accuracies:Rectifier type meter- ±1.5% @ 25˚C calibrated to sine wave.Expanded Scale Voltmeter- 0.3% of mid-scale.Power factor meter- ±1% of scale length from 20-100% of rated current on balanced system models; ±3% of scale length on unbalanced system model types.Synchroscope- ±1% of scale length.Frequency meters- ± .15Hz @45-55Hz and 55-65Hz, ±0.093Hz @58-62Hz, ±1.5Hz @350-450Hz.Position of use: Vertical (scale)Full scale deflection angle: 250˚, except synchroscope is 360˚Full scale length:AB/DB40, AB/DB14, 6.9 inches.AB/DB16- 13.8 inches.Scale plate: AB/DB40, AB/DB14 platform type 2 piece scale with graduations on the outer scale; numerals and legends on the inner scale or one-piece lasered scale (standard). AB/DB16, has a one piece platform scale orflat lasered scale (standard).Case: All AB/DB switchboard instruments have drawn steel case withzinc chromate coating except AB/DB40 plastic case which is ABS.Cover: AB/DB14, metal cover with polycarbonate window. AB/DB16, AB/DB40
polycarbonate-UL94V-0 cover and window.Terminal plate: phenol resin material.Mounting studs: 1/4” x 28 thread.Terminal studs: 10-32 thread.Operating temperature range: 0 to 40˚C (32 to 104˚F).Storage temperature range: -10 to 50˚C (14 to 122˚F).Extreme temperature range: -20˚C to 65˚C (-4 to 149˚F). Dielectric level: 2300VAC for 1 minute between the electrical circuit and mountingstuds.Overload rating: Voltmeter and potential coils-1.2 x rating (continuous).AC Ammeters- 2 x rating (continuous), and 10 x rating for one second.Current coils (other than ammeters) 1.5 x rating (continuous), and 10 xrating for one second.Response time: Approximately 2.5 seconds (except AB/DB16)UL File: E91703
Notes: * Requires external transducer, X = available, N/A = Not available in this model, † = rectifier type.
CONTENTS
AB/DB Switchboard Instruments
Page 5 Key to Switchboard numbering system, how to order, shipping and storage weights.
Page 6 Selector guide, general specifications, catalog contents.Page 7-10 AC/DC Ammeters, Voltmeters, Tach. indicators.Page 11-13 Dual-Vue meters.
Page 14 Power Factor, Frequency meters,Synchroscopes, Temperature meters.
Page 15 AB40 Hour meter.Page 16 AC Wattmeters and Varmeters.Page 17-22 Application guide for selection of Wattmeters
and Varmeters.Page 23 Optional features for AB/DB40 and AB/DB16. Page 24 Switchboard minimum / maximum ratings.Page 25 Switchboard specification and burden data.Page 26-28 Standard connection drawings for AB/DB40 and AB/DB16.Page 29-32 Dimensions and panel cutout drawings.
Type 180 Edgewise Instruments.
Rudder Meter
Page 33-35 General specifications, catalog numbers,Optional features, dimensions and cutouts.
Page General specifications, catalog numbers,Optional features, dimensions and cutouts.
Type 2180 Miniature Switchboard Instruments
Page 36-37
38-39
General specifications, ordering information,dimensions and panel cutout.
SWITCHBOARD INSTRUMENT SELECTOR GUIDE
............................................................................................................................................................................7
S W I T C H B O A R D I N S T R U M E N T S
Rating (Amperes) Scale (Amperes) AB-14 Cat. No. AB-40 Metal Case AB-40 Plastic Case AB-16 Cat. No.
Self-Contained, 40/70 Hz
1 0–1 101 133 LALA 103 131 LALA 103 131 LALA7/P 121 131 LALA1.5 0–1.5 101 133 LCLC 103 131 LCLC 103 131 LCLC7/P 121 131 LCLC2 0–2 101 133 LELE 103 131 LELE 103 131 LELE7/P 121 131 LELE3 0–3 101 133 LJLJ 103 131 LJLJ 103 131 LJLJ7/P 121 131 LJLJ5 0–5 101 133 LSLS 103 131 LSLS 103 131 LSLS7/P 121 131 LSLS7.5 0–7.5 101 133 MFMF 103 131 MFMF 103 131 MFMF7/P 121 131 MFMF10 0–10 101 133 MTMT 103 131 MTMT 103 131 MTMT7/P 121 131 MTMT15 0–15 101 133 NDND 103 131 NDND 103 131 NDND7/P 121 131 NDND20 0–20 101 133 NGNG 103 131 NGNG 103 131 NGNG7/P 121 131 NGNG30 0–30 101 133 NLNL 103 131 NLNL 103 131 NLNL7/P —
Transformer-Rated, 40/70Hz
5 0–10 101 133 LSMT 103 131 LSMT 103 131 LSMT7/P 121 131 LSMT5 0–15 101 133 LSND 103 131 LSND 103 131 LSND7/P 121 131 LSND5 0–20 101 133 LSNG 103 131 LSNG 103 131 LSNG7/P 121 131 LSNG5 0–25 101 133 LSNJ 103 131 LSNJ 103 131 LSNJ7/P 121 131 LSNJ5 0–30 101 133 LSNL 103 131 LSNL 103 131 LSNL7/P 121 131 LSNL5 0–40 101 133 LSNP 103 131 LSNP 103 131 LSNP7/P 121 131 LSNP5 0–50 101 133 LSNT 103 131 LSNT 103 131 LSNT7/P 121 131 LSNT5 0–75 101 133 LSPB 103 131 LSPB 103 131 LSPB7/P 121 131 LSPB5 0–100 101 133 LSPK 103 131 LSPK 103 131 LSPK7/P 121 131 LSPK5 0–150 101 133 LSPZ 103 131 LSPZ 103 131 LSPZ7/P 121 131 LSPZ5 0–200 101 133 LSRL 103 131 LSRL 103 131 LSRL7/P 121 131 LSRL5 0–250 101 133 LSRS 103 131 LSRS 103 131 LSRS7/P 121 131 LSRS5 0–300 101 133 LSRX 103 131 LSRX 103 131 LSRX7/P 121 131 LSRX5 0–400 101 133 LSSC 103 131 LSSC 103 131 LSSC7/P 121 131 LSSC5 0–500 101 133 LSSF 103 131 LSSF 103 131 LSSF7/P 121 131 LSSF5 0–600 101 133 LSSJ 103 131 LSSJ 103 131 LSSJ7/P 121 131 LSSJ5 0–800 101 133 LSSN 103 131 LSSN 103 131 LSSN7/P 121 131 LSSN5 0–1000 101 133 LSSS 103 131 LSSS 103 131 LSSS7/P 121 131 LSSS5 0–1200 101 133 LSSV 103 131 LSSV 103 131 LSSV7/P 121 131 LSSV5 0–1500 101 133 LSTC 103 131 LSTC 103 131 LSTC7/P 121 131 LSTC5 0–2000 101 133 LSTM 103 131 LSTM 103 131 LSTM7/P 121 131 LSTM5 0–2500 101 133 LSTV 103 131 LSTV 103 131 LSTV7/P 121 131 LSTV5 0–3000 101 133 LSUA 103 131 LSUA 103 131 LSUA7/P 121 131 LSUA5 0–4000 101 133 LSUE 103 131 LSUE 103 131 LSUE7/P 121 131 LSUE5 0–5000 101 133 LSUJ 103 131 LSUJ 103 131 LSUJ7/P 121 131 LSUJ5 0–6000 101 133 LSUP 103 131 LSUP 103 131 LSUP7/P 121 131 LSUP5 0–7000 101 133 LSUS 103 131 LSUS 103 131 LSUS7/P 121 131 LSUS5 0–8000 101 133 LSUW 103 131 LSUW 103 131 LSUW7/P 121 131 LSUW
Instruction Book: 4555K10P0701, Outline Dimensions: See pages 29 and 32
AC Ammeters
AB-40Metal Case
AB-40Plastic Case
............................................................................................................................................................................8
S W I T C H B O A R D I N S T R U M E N T S
Rating (Volts) Scale (Volts) AB-14 Cat. No. AB-40 Metal Case AB-40 Plastic Case AB-16 Cat. No.Self-Contained, 50/60 Hz
150 0–150 101 023 PZPZ 103 021 PZPZ 103 021 PZPZ7/P 121 021 PZPZ250 0–250 101 023 RSRS 103 021 RSRS 103 021 RSRS7/P 121 021 RSRS300 0–300 101 023 RXRX 103 021 RXRX 103 021 RXRX7/P 121 021 RXRX500 0–500 101 023 SFSF 103 021 SFSF 103 021 SFSF7/P 121 021 SFSF600 0–600 101 023 SJSJ 103 021 SJSJ 103 021 SJSJ7/P 121 021 SJSJ750s 0–750 ** 103 021 SMSM 103 021 SMSM7/P 121 021 SMSM
Transformer-Rated, 50/60 Hz150 0–300 101 023 PZRX 103 021 PZRX 103 021 PZRX7/P 121 021 PZRX150 0–600 101 023 PZSJ 103 021 PZSJ 103 021 PZSJ7/P 121 021 PZSJ150 0–750 101 023 PZSM 103 021 PZSM 103 021 PZSM7/P 121 021 PZSM150 0–3000 101 023 PZUA 103 021 PZUA 103 021 PZUA7/P 121 021 PZUA150 0–5250 101 023 PZUL 103 021 PZUL 103 021 PZUL7/P 121 021 PZUL150 0–6000 101 023 PZUP 103 021 PZUP 103 021 PZUP7/P 121 021 PZUP150 0–9000 101 023 PZUY 103 021 PZUY 103 021 PZUY7/P 121 021 PZUY150 0–15kV 101 023 PZWZ 103 021 PZWZ 103 021 PZWZ7/P 121 021 PZWZ150 0–18kV 101 023 PZXE 103 021 PZXE 103 021 PZXE7/P 121 021 PZXE150 0–45kV 101 023 PZXU 103 021 PZXU 103 021 PZXU7/P 121 021 PZXU150 0–150kV 101 023 PZYR 103 021 PZYR 103 021 PZYR7/P 121 021 PZYR250 0–600V 101 023 RSSJ 103 021 RSSJ 103 021 RSSJ7/P 121 021 RSSJ
Expanded Scale, Self-Contained, 50/60 HZ110–130 110–130 ** 103 071 PNPN 103 071 PNPN7/P 121 071 PNPN
Expanded Scale, Transformer Rated, 50/60 HZ*. . NP 170 121*P/7..NP 170 301*. . NP 170 301**†031–011
Rectifier Type, 1.5% Accuracy, 20 to 3000 Hz15 0–15 ** 103151NDND 103151NDND 71P 121151NDND
LNLN151121P17 LNLN151301LNLN151301**03–003150 0–150 ** 103151PZPZ 103151PZPZ 71P 121151PZPZ
*ZP151121P17 *ZP151301*ZP151301**†051300 0–300 ** 103151RXRX 103151RXRX 71P 121151RXRX600 0–600 ** 103151STST 103151STST 71P 121151SJSJ
Ground Detector Type — Single-Phase 50/60 Hz150 0–150 ** 103 021 PZPZ 103 021 PZPZ7/P 121 021 PZPZ150 † ** 103 021 PZ. .* 103 021 PZ. .*7/P 121 021 PZ. .*300 0–300 ** 103 021 RXRX 103 021 RXRX7/P 121 021 RXRX600 0–600 ** 103 021 SJSJ 103 021 SJSJ7/P 121 021 SJSJ
Instruction Book: 4555K10P0701, Outline Dimensions: see pages 29 and 32
AC Voltmeters
AB-40Metal Case
AB-40Expanded Scale
sUL version not available.* Order by description. Specify P.T. (Potential Transformer) ratio if used, and scale desired.** High shock version not available.† Scale per requisition. AB/DB models have maximum 4 digits as standard.
............................................................................................................................................................................9
S W I T C H B O A R D I N S T R U M E N T S
Scale and Rating DB-14 Cat. No. DB-40 Metal Case DB-40 Plastic Case DB-16 Cat. No.Microammeters — Zero-Left
—P/7AEAE 111 301AEAE 111 301**002–00–300 101 113 EGEG 103 111 EGEG 103 111 EGEG7/P 121 111 EGEG0–500 101 113 EMEM 103 111 EMEM 103 111 EMEM7/P 121 111 EMEM
Milliammeters — Zero-Lefts 0–1 101 113 FAFA 103 111 FAFA 103 111 FAFA7/P 121 111 FAFA
0–2 101 113 FGFG 103 111 FGFG 103 111 FGFG7/P 121 111 FGFG0–5 101 113 FXFX 103 111 FXFX 103 111 FXFX7/P 121 111 FXFX0–10 101 113 GZGZ 103 111 GZGZ 103 111 GZGZ7/P 121 111 GZGZ0–30 101 113 HMHM 103 111 HMHM 103 111 HMHM7/P 121 111 HMHM0–50 101 113 HYHY 103 111 HYHY 103 111 HYHY7/P 121 111 HYHY0–100 101 113 JRJR 103 111 JRJR 103 111 JRJR7/P 121 111 JRJR0–200 101 113 KAKA 103 111 KAKA 103 111 KAKA7/P 121 111 KAKA0–300 101 113 KGKG 103 111 KGKG 103 111 KGKG7/P 121 111 KGKG0–500 101 113 KMKM 103 111 KMKM 103 111 KMKM7/P 121 111 KMKM
MIlliammeters — Suppressed-Zero (No zero set unless otherwise specified)10–50 101 193 HX…† 103 191 HX…† 103 191 HX...†7/P 121 191 HX…†
s 4–20 101 193 HE…† 103 191 HE…† 103 191 HE…†7/P 121 191 HE…†1–5 101 193 FY…† 103 191 FY…† 103 191 FY…†7/P 121 191 FY…†
Ammeters — Zero-Left0–1 101 113 LALA 103 111 LALA 103 111 LALA7/P 121 111 LALA0–5 101 113 LSLS 103 111 LSLS 103 111 LSLS7/P 121 111 LSLS0–10 101 113 MTMT 103 111 MTMT 103 111 MTMT7/P 121 111 MTMT0–15 101 113 NDND 103 111 NDND 103 111 NDND7/P 121 111 NDND0–20 101 113 NGNG 103 111 NGNG 103 111 NGNG7/P 121 111 NGNG0–30 101 113 NLNL 103 111 NLNL 103 111 NLNL7/P 121 111 NLNL
Instruction Book: 4555K10P0701, Outline Dimensions: see pages 29 and 32
DC Ammeters Self Contained
** High shock not available* Scale marked in terms of shunt current. When ordering specify rating of shunt to be used, scale and legend. AB/DB meter scales
have a maximum of 4 digits.Shunt-rated instruments are normally calibrated for 5-foot shunt leads (0.050 Ohms). They can be calibrated for maximumresistances as follows: 50mV 100mV
2.0 Ohms 5.0 Ohms
Rating (Millivolts) Scale (Amperes) DB-14 Cat. No. DB-40 Metal Case DB-40 Plastic Case DB-16 Cat. No.With Lead Length Compensator, Catalog Number Does Not Include Shunt or Shunt Leads
…BA 121 121P/7…BA 121 301…BA 121 301***0550–0–50 * 101 124 AB… 103 122 AB… 103 122 AB…7/P 121 122 AB…
…EA 121 121P/7…EA 121 301…EA 121 301…EA 321 101*001100–0–100 * 101 124 AE… 103 122 AE… 103 122 AE…7/P 121 122 AE…
Zero-Left for Use with 50mV Shunts and 0.05-Ohm Shunt Leads, (Standard 5-Foot Leads). s See page 37 for External Shunts (Shunts and Leads are not included with meter).
50 0–15 101 123 CAND 103 121 CAND 103 121 CAND7/P 121 121 ECND50 0–20 101 123 CANG 103 121 CANG 103 121 CANG7/P 121 121 ECNG50 0–30 101 123 CANL 103 121 CANL 103 121 CANL7/P 121 121 ECNL50 0–40 101 123 CANP 103 121 CANP 103 121 CANP7/P 121 121 ECNP50 0-50 101 123 CANT 103 121 CANT 103 121 CANT7/P 121 121 ECNT50 0–75 101 123 CAPB 103 121 CAPB 103 121CAPB7/P 121 121 ECPB50 0–100 101 123 CAPK 103 121 CAPK 103 121 CAPK7/P 121 121 ECPK50 0–150 101 123 CAPZ 103 121 CAPZ 103 121 CAPZ7/P 121 121 ECPZ50 0–200 101 123 CARL 103 121 CARL 103 121 CARL7/P 121 121 ECRL50 0–300 101 123 CARX 103 121 CARX 103 121 CARX7/P 121 121 ECRX50 0–400 101 123 CASC 103 121 CASC 103 121 CASC7/P 121 121 ECSC50 0–500 101 123 CASF 103 121 CASF 103 121 CASF7/P 121 121 ECSF50 0–750 101 123 CASM 103 121 CASM 103 121 CASM7/P 121 121 ECSM50 0–1000 101 123 CASS 103 121 CASS 103 121 CASS7/P 121 121 ECSS50 0–1200 101 123 CASV 103 121 CASV 103 121 CASV7/P 121 121 ECSV50 0–1500 101 123 CATC 103 121 CATC 103 121 CATC7/P 121 121 ECTC50 0–2000 101 123 CATM 103 121 CATM 103 121 CATM7/P 121 121 ECTM50 0–3000 101 123 CAUA 103 121 CAUA 103 121 CAUA7/P 121 121 ECUA
Instruction Book: 4555K10P0701, Outline Dimensions: see pages 29 and 32
DC Ammeters Shunt-Rated
DB-40 Metal Case
DB-40 Plastic Case
t
s Refer to Power Transducer Catalog† Scale per requisition. (AB/DB-40/16) have a maximum of 4 digits as standard.** High shock version not available.
............................................................................................................................................................................10
S W I T C H B O A R D I N S T R U M E N T S
Rating and Scale (Volts) DB-14 Cat. No. DB-40 Metal Case DB-40 Plastic Case DB-16 Cat. No.Zero-Left (Sensitivity is 1000 OHMS / Volt)
0–15 101 013 NDND 103 011 NDND 103 011 NDND7/P 121 011 NDND0–30 101 013 NLNL 103 011 NLNL 103 011 NLNL7/P 121 011 NLNL0–50 101 013 NTNT 103 011 NTNT 103 011 NTNT7/P 121 011 NTNT0–75 101 013 PBPB 103 011 PBPB 103 011 PBPB7/P 121 011 PBPB0–150 101 013 PZPZ 103 011 PZPZ 103 011 PZPZ7/P 121 011 PZPZ0–300 101 013 RXRX 103 011 RXRX 103 011 RXRX7/P 121 011 RXRX0–400 101 013 SCSC 103 011 SCSC 103 011 SCSC7/P 121 011 SCSC0–500 101 013 SFSF 103 011 SFSF 103 011 SFSF7/P 121 011 SFSF0–600 101 013 SJSJ 103 011 SJSJ 103 011 SJSJ7/P 121 011 SJSJ
Zero-Center (Sensitivity is 2000 OHMS / Volt)150–0–150 101 014 PZPZ 103 012 PZPZ 103 012 PZPZ7/P 121 012 PZPZ300–0–300 101 014 RXRX 103 012 RXRX 103 012 RXRX7/P 121 012 RXRX500–0–500 101 014 SFSF 103 012 SFSF 103 012 SFSF7/P 121 012 SFSF600–0–600 101 014 SJSJ 103 012 SJSJ 103 012 SJSJ7/P 121 012 SJSJ
Ground Detector Type — Zero-Center for 2-Wire Circuits (Standard Sensitivity is 1000 OHMS/Volt) ‡150–0–150 ** 103 552 PZ† 103 552 PZ†7/P 121 552 PZ†300–0–300 ** 103 552 RX† 103 552 RX†7/P 121 552 RX†500–0–500 ** 103 552 SF† 103 552 SF†7/P 121 552 SF†600–0–600 ** 103 552 SJ† 103 552 SJ†7/P 121 552 SJ†
Instruction Book: 4555K10P0701, Outline Dimensions pages 29 and 32
DC Volts 103621RRSSSelect nearest higher rated DC Voltmeter from above and specify requirements.
AC Volts 103631RRSSSelect nearest higher rated rectifier type AC voltmeter from Page 8 and specify requirements.
Instruction Book 4555K15P0003
Tachometer Indicators
DB-40 Metal CaseDB-40 Tachometer DB-40 Plastic Case
† Specify scale by order.‡ Includes (2) 2227 External Resistors.** High shock version not available.
DC Voltmeters
............................................................................................................................................................................11
S W I T C H B O A R D I N S T R U M E N T S
Features analog and digital display to provide the ultimate inreadability of power and control parameters. A drop-in replacement for upgrade of existing control andswitchgear panels. Rugged switchboard style case and IP54 rated cover. Choice of high-intensity LED digital displays with highreliability analog movements. Standard models for AC or DC voltage and current, withcustom scales and legends available as options.
DUAL-VUE switchboard meter specifications:
General DescriptionDUAL-VUE switchboard meters are combination Digital/Analogindicating instruments. They can be configured to accept ACV,ACA, DCV, or DCA input. Both the digital and analog displayscan be modified to represent virtually any scaling or engineer-ing units as required. The unit is contained in a 4 1/4”Switchboard housing. It utilizes a taut band moving elementand a 0.56”, 3 1/2 digit display for indication (+ or – 1999counts).
Electrical Specifications
Input Ratings:
DCV – Standard inputs are 0-50mV, 100mV 200mV, 10V, 100V,150V, 300V, 600V, +/-50mV, +/-100mV, +/-200mV, +/-10V, +/-100V, +/-150V, +/-300V, +/-600V Input impedance = 1MΩ
DCA – Standard inputs are 0-200uA, 500uA,1mA, 10mA, 100mA,500mA, 1A, +/- 200uA, +/-500uA, +/-1mA, +/-10mA, +/-100mA,+/-500mA, +/-1A, 1-5mA, 4-20mA, 10-50mA Voltage Drop <210mV (inputs < 500mA),< 510mV (inputs < 500mA)
ACV – Standard inputs are 0-150V, 250V, 300V, 600V Inputimpedance = 1MΩ Input Frequencies 45Hz to 65Hz
ACA – Standard inputs are 0-1A, 0-5A (Transformer coupled)Input Frequencies 45Hz to 65Hz Other ratings are possible.Contact Yokogawa for special ratings.
Scaling: Scaling options are limited only in that there can be nooffset zero scaling for the digital display.
Overload:Voltage Inputs:x 1.2 continuous or 700V max; x 1.5 for 10 secondsDC Current:x 1.2 continuous; x 1.5 for 10 secondsAC Current:x 2 continuous; x 5 for 10 seconds
Burden: ACV < 0.5VA @ 600VACACA < 0.2VA @ 5AACDCV < 0.5W @ 600VDCDCA < 0.5W @ 1ADC
Isolation Test Voltage:2KV for 60 seconds aux. power to input, aux. power to case,input to case.
Power Supply
Voltage:120V +/-15% standard ; optional 240V +/15%,125VDC±15VDC, 24VDC±6VDC, 48VDC±12VDC
Frequency: 50/60Hz +/- 2Hz (48Hzto 62Hz)Burden:
............................................................................................................................................................................12
S W I T C H B O A R D I N S T R U M E N T S
DC VOLTMETERS AND AMMETERSwhite scale with black markings + pointer, specify auxiliary power code.
Notes:Replace with the appropiate power supply code: 1=120VAC
2= 240VAC3= 125VDC4= 24VDC5= 48VDC
1) For non-standard inputs and scales(or aux. power) select the closest rated input model from above and specifyper example. “Similar to model 123191HEHE except...”Input signal: 4-12-20mA dcAnalog scale:-1900-0-+1900 Scale color: white, letters + numerals: black, pointer: blackAnalog legend: DC AmperesDigital scale:+/-1900Digital sub-legend: only required when digital scale is different value from analog.Auxiliary power: 120VAC is standard: 240VAC, 24VDC, 48VDC, and 125VAC are optional.
2) Non-standard models will be assigned a special 3 letter suffix at Yokogawa (ex: 123191HEHE/xxx)
Input Rating/scale Red LEDModel#
Green LEDModel#
DCV 0-50mV0-100mV0-200mV
50-0-50mV100-0-100mV200-0-200mV
0-10V0-100V0-150V0-300V0-600V
10-0-10V100-0-100V150-0-150V300-0-300V600-0-600V
123011ABAB123011AEAE123011 AHAH123012 ABAB123012AEAE123012AHAH123011MTMT123011PKPK123011PZPZ123011RXRX123011SJSJ123012MTMT123012PKPK123012PZPZ123012RXRX123012SJSJ
124011ABAB124011AEAE124011 AHAH124012 ABAB124012AEAE124012AHAH124011MTMT124011PKPK124011PZPZ124011RXRX124011SJSJ124012MTMT124012PKPK124012PZPZ124012RXRX124012SJSJ
DCA 0-200uA0-500uA
200-0-200uA500-0-500uA
0-1mA0-10mA
0-100mA0-500mA
0-1A1-0-1mA
10-0-10mA100-0-100mA500-0-500mA
1-0-1A1-5mA
4-20mA10-50mA
123111EAEA123111EMEM123112EAEA123112EMEM123111FAFA123111GZGZ123111JRJR123111KMKM123111LALA123112FAFA123112GZGZ123112JRJR123112KMKM123112LALA123191FYFY123191HEHE123191HXHX
124111EAEA124111EMEM124112EAEA124112EMEM124111FAFA124111GZGZ124111JRJR124111KMKM124111LALA124112FAFA124112GZGZ124112JRJR124112KMKM124112LALA124191FYFY124191HEHE124191HXHX
............................................................................................................................................................................13
S W I T C H B O A R D I N S T R U M E N T S
AC VOLTMETERS AND AMMETERSwhite scale with black markings and pointer, specify auxiliary power code.
Notes:Replace with the appropiate power supply code: 1=120VAC
2= 240VAC3= 125VDC4= 24VDC5= 48VDC
1) For non-standard inputs and scales (or aux. power) select the closest rated input model from above and specify per example.“Similar to model 123131LSLS except...”Input signal: 0 - 5A ACAnalog scale: 0 - 1900, Scale color: white, letters + numerals: black, pointer: blackAnalog legend: AC AmperesDigital scale: 0 - 1900Digital sub-legend: only required when digital scale is different value from analog.Auxiliary power: 120VAC is standard: 240VAC, 24VDC, 48VDC and 125VDC are optional.
2) Non-standard models will be assigned a special 3 letter suffix at Yokogawa (ex: 123131LSLS/xxx)
Input Rating/scale Red LEDModel#
Green LEDModel#
ACV 0-150V0-250V0-300V0-600V
123021PZPZ123021RSRS123021RXRX123021SJSJ
124021PZPZ124021RSRS124021RXRX124021SJSJ
Transformer Rated(150V)
0-150V/0-250V0-150V/0-300V0-150V/0-500V0-150V/0-600V0-150V/0-750V0-150V/0-1500V0-150V/0-3.00kV0-150V/0-5.00kV0-150V/0-5.25kV0-150V/0-6.00kV0-150V/0-9.00kV0-150V/0-15.00kV0-150V/0-18.00kV0-150V/0-45.0kV0-150V/0-150.0kV0-150V/0-200kV0-250V/0-600V
123021PZRS123021PZRX123021PZSF123021PZSJ123021PZSM123021PZTC123021PZVJ123021PZVT123021PZVV123021PZVX123021PZWJ123021PZWZ123021PZXE123021PZXU123021PZYR123021PZYU123021RSSJ
124021PZRS124021PZRX124021PZSF124021PZSJ124021PZSM124021PZTC124021PZVJ124021PZVT124021PZVV124021PZVX124021PZWJ124021PZWZ124021PZXE124021PZXU124021PZYR124021PZYU124021RSSJ
ACA 0-1A0-5A
123131LALA123131LSLS
124131LALA124131LSLS
Transformer Rated(5A)
0-5A/0-10.00A0-5A/0-15.00A0-5A/0-20.0A0-5A/0-25.0A0-5A/0-30.0A0-5A/0-40.0A0-5A/0-50.0A0-5A/0-75.0A0-5A/0-100.0A0-5A/0-150.0A0-5A/0-200A0-5A/0-250A0-5A/0-300A0-5A/0-400A0-5A/0-500A0-5A/0-600A0-5A/0-800A0-5A/0-1000A0-5A/0-1200A0-5A/0-1500A
123131LSMT123131LSND123131LSNG123131LSNJ123131LSNL123131LSNP123131LSNT123131LSPB123131LSPK123131LSPZ123131LSRL123131LSRS123131LSRX123131LSSC123131LSSF123131LSSJ123131LSSN123131LSSS123131LSSV123131LSTC
124131LSMT124131LSND124131LSNG124131LSNJ124131LSNL124131LSNP124131LSNT124131LSPB124131LSPK124131LSPZ124131LSRL124131LSRS124131LSRX124131LSSC124131LSSF124131LSSJ124131LSSN124131LSSS124131LSSV124131LSTC
............................................................................................................................................................................14
S W I T C H B O A R D I N S T R U M E N T S
Synchroscopes — Pivot & JewelScale Voltage Normal Frequency AB-40 Cat. No. AB-16 Cat. No.
AADA 254 021AADA 254 60106/05021 ”tsaF-wolS“AACA 254 021AACA 254 601 004021 ”tsaF-wolS“AADD 254 021AADD 254 60106/05042 ”tsaF-wolS“
''Slow-Fast'' 240 400 106 452 DCAA 120 452 DCAAInstruction Book: IM106452-50-60, Outline Dimensions: See page 29
Rating (V .oN .taC 61-BD.oN .taC 04-BDelacS)stlo1-Percent of Span for 10-ohm copper RTDs (Resistance Temperature Detectors) 50-600 Hz
120 20 –140°C 103 502 CAAB† 121 502 CAAB†120 0–180°F 103 502 CDAD† 121 502 CDAD†
Instruction Book: 4555K12P0001, Outline Dimensions: See page 29
Temperature Indicators (Lead Resistance = 0.3 ohms)
† Catalog number includes calibrated test resistor
Scale (Hz) Center Frequency (Hz) Accuracy (Hz) AB-40 Cat. No. AB-16 Cat. No.45–55 GAGA 273 121GAGA 273 30151.0±05
JAJA 273 121JAJA 273 30152.0±5556–5448–52 50 ±0.093 103 372 AKAK 121 372 AKAK
LALA 273 121LALA 273 30152.0±0607–0555–65 60 ±0.15 103 372 ANAN 121 372 ANAN58–62 60 ±0.093 103 372 ATAT 121 372 ATAT
SASA 273 121SASA 273 301740.0±0616–95350–450 HBHB 273 121HBHB 273 3013.1±004390–410 LBLB 273 121LBLB 273 301294.0±004
Instruction Book: 4555K24P0001, Outline Dimensions: See page 29
Frequency Meters, 120V
*240 V L-N
Rating (Amperes) Rating (L-L Volts) Scale AB-40 Cat. No. AB-16 Cat. No.Single-Phase/2-Wire, 50/60Hz
DACF 214 121DACF 214 3015.–1–5.02153-Phase 3- & 4-Wire, 50/60Hz Balanced System Only
DACF 204 121DACF 204 3015.–1–5.0215—DADF 204 3015.–1–5.8025
DAEF 204 121DAEF 204 3015.–1–5.0425—DAFF 204 3015.–1–5.0845—DAGF 204 3015.–1–5.0065
3-Phase 3-Wire, 60Hz Unbalanced Systems —DACF 264 3015.–1–5.0215—DAEF 264 3015.–1–5.0425
3-Phase 4-Wire, 60Hz Unbalanced Systems —DACF 274 3015.–1–5.0215—DADF 274 3015.–1–5.8025—DAEF 274 301 5.–1–5.*6145
Instruction Book: 4555K35P0701 (For Unbalanced), Outline Dimensions: See page 29Instruction Book: 4555K25P0001 (For Balanced), Outline Dimensions: See page 29
Power-Factor Meters
POWER FACTOR SCALE
FORBALANCED
SYSTEM
............................................................................................................................................................................15
S W I T C H B O A R D I N S T R U M E N T S
The AB40 switchboard hour meter contains the time-proven 240 elapsed time meter in a 4.33” square weather-resistant case. It isdesigned for use with other switchboard instruments on electrical switchgear and control panels. It is UL/CSA recognized under fileE91703 and meets ANSI C39.1 specifications for shock and vibration. Accuracy of these AC hour meters matches the frequency con-trol of the power system. Models are available with a time range of 0 to 99,999.9 hours in reset and non-reset configurations. Thereset model requires the removal of the cover in order to perform the reset function.
Reset Type Non-Reset Type
ORDERING SPECIFICATIONS
SPECIFICATIONSAccuracy: Matches frequency control of the power systemVibration/Shock: Meets ANSI specification C39.1Materials: Polycarbonate cover and zinc-coated steel caseSafety: UL recognized under UL file E91703Presentation: Six digit counter with 5/32” high digitsInsulation level: 2000VAC for one minute Burden: Three watts typical Motor: SynchronousDimensions: Outline dimensions and cutout on page 31
AB 40 hour meterreset type
AB 40 hour meterNon-reset type
AC voltage ratingand frequency
103822AAAB103822ADAB103822AGAB103822AHAB103822ABAB103822AEAB103822ACAB103822AFAB
103811AAAB103811ADAB103811AGAB103811AHAB103811ABAB103811AEAB103811ACAB103811AFAB
120V-60Hz120V-50Hz208V-60Hz208V050Hz240V-60Hz240V-50Hz480V-60Hz480V-50Hz
SWITCHBOARD TIME METER
............................................................................................................................................................................16
S W I T C H B O A R D I N S T R U M E N T S
Rating (Amperes) Rating (Volts) Scale AB-40 Cat. No. AB-16 Cat. No.Single-Phase/2-Wire, 1-Element, Transformer Rated, 50/60Hz
5 120 † 103 31 A …… 121 31 A ……5 120 † 103 762 A ……* 121 762 A……*
3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60Hz (Cannot be used with External Phase Shifter)5 120 † 103 28 A 121 28 A.... 5 120 † 103 812 A …… 121 812
3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60Hz For Use With External Phase Shifters 5 120 † 103 32 A …… 121 32 A5 120 † 103 772 A .....* 121 77 2 A*
3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 50/60Hz (Cannot be used with External Phase Shifter)5 208 H † 103 29 B.... 121 29 B....5 208 H † 103 742 B.... s 121 742 B.... s
3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 50/60Hz For Use with External Phase Shifters 5 120 † 103 34 A …… 121 34 A .....5 120 † 103 792 A ....* 121 792 A ....*
Instruction Book: 4555K27P0701, Outline Dimensions: See page 29
Rating (Amperes) Rating (Volts) Scale AB-40 Cat. No. AB-16 Cat. No.Single-Phase/2-Wire, 1-Element, Transformer-Rated, 50/60 Hz
12 301†0215 A …… 121 21 A ……3-Phase/3-Wire, 2-Element, Transformer-Rated, 50/60Hz
5 120 † 103 22 A …… 121 22 A ……5 240 † 103 22 C …… 121 22 C ……
22 301†*0845 D …… — 22 301†*0065 E …… —
3-Phase/4-Wire, 21⁄2-Element, Transformer-Rated, 50/60Hz, (Voltage balanced) 5 69 † 103 25 F 121 25 F5 120 † 103 25 A …… 121 25 A ……
52 301†0425 C …… 121 25 C ……Instruction Book: 4555K26P0701, Outline Dimensions: See page 29
AC Wattmeters Non-Isolated (cannot be used with external Phase Shifter for Vars)
† Order by description. Specify CT (Current Transformer) and/or PT (Potential Transformer) ratios if used and scale desired.* UL version in short case, non-UL version in long case.
Sixth digit signifies pointer deflection (1-zero-left, 2-zero-center).
† Order by description. Specify CT (Current Transformer) and/or PT (Potential Transformer) ratios if used and scale desired.* Used for 0-Center when calibrating watts are less than ±380.
Used for 0-Center when calibrating watts are less than ±658.s Used for 0-Center when calibrating watts are less than ±760.H The 21⁄2-element varmeters used on 4-wire 3-phase 120V L-N systems are rated 208V because they are connected line-
to-line.Sixth digit signifies pointer deflection (1-zero left, 2-zero center).
Varmeters (Voltages must be balanced for all polyphase Varmeters)
NOTE:See Application Guide and
Tables on the followingsix pages for selection of
commonly used Watt and VarMeters.
Varmeters are usually zero-center and scaled for half the scale values of the accompanying wattmeters. Example: If the Wattmeter is scaled 0-100 Kilowatts, the Varmeter is scaled 50-0-50 Kilovars.
............................................................................................................................................................................17
S W I T C H B O A R D I N S T R U M E N T S
Digit 14 Wattmeters Varmeters
A None NoneB AC Watts VarsC AC Kilowatts Kilovars
Digit 14 Wattmeters Varmeters
D AC Megawatts MegavarsE AC Watts/Vars* —F AC KW/Var* s —
Digit 14 Wattmeters Varmeters
G AC MW/Var* s —T Percent Horsepower —U Horsepower —
APPLICATION GUIDE FOR SELECTION OFWATTMETERS AND VARMETERS
Key to Watt/Varmeter ScalesCat. Digit Cat. Digit Cat. Digit Cat. Digit Cat. Digit
12, 13 Scale 12, 13 Scale 12, 13 Scale 12, 13 Scale 12, 13 Scale
AA 1 BA 10 CA 100 DA 1000 EA BLANKAC 1.2 BC 12 CC 120 DC 1200 EC 1.2AD 1.4 BD 14 CD 140 DD 1400 EE 1.6
AE 1.5 BE 15 CE 150 DE 1500 FC 12.5AF 1.8 BF 18 CF 180 DF 1800 FD 13AG 2 BG 20 CG 200 DG 2000 FE 16
AH 2.4 BH 24 CH 240 DH 2400 FG 17.5AJ 2.5 BJ 25 CJ 250 DJ 2500 FJ 26AK 3 BK 30 CK 300 DK 3000 GB 115
AL 3.2 BL 32 CL 320 DL 3200 GC 125AM 3.5 BM 35 CM 350 DM 3500 GD 130AN 4 BN 40 CN 400 DN 4000 GE 160
AP 4.5 BP 45 CP 450 DP 4500 GG 175AR 5 BR 50 CR 500 DR 5000 GH 230AS 5.5 BS 55 CS 550 DS 5500 GJ 260
AT 6 BT 60 CT 600 DT 6000 HC 1250AU 6.5 BU 65 CU 650 DU 6500 HD 1300AW 7 BW 70 CW 700 DW 7000 HE 1600
AX 7.5 BX 75 CX 750 DX 7500 HG 1750AY 8 BY 80 CY 800 DY 8000AZ 9 BZ 90 CZ 900 DZ 9000
1. For polyphase applications, see Selector Tables II-V. Thesetables display complete catalog numbers for use with com-monly used combinations of CT and PT ratios. For singlephase applications, order by description.
For 3-wire 3-phase wattmeters rated 120 volts, 5A see TABLEII on page 13.
For 3-wire 3-phase varmeters rated 120 volts, 5A see TABLE IV on page 15.
For 4-wire 3-phase wattmeters rated 120 volts, 5A see TABLEIII on page 14.
For 4-wire 3-phase varmeters rated 208 volts, 5A see TABLE V on page 16.
2. If scale is required to be higher or lower than the pre-selected scale shown in the above tables, see TABLE I onpage 12. Choose a scale value between the maximum andminimum shown on this table for the combination of CTand PT ratios. Order by description, giving CT and PT ratios
and choice of scale.
3. For transformer ratios and/or ratings not shown in theabove tables, see Scale Watts Formula on page 12. This tableshows minimum and maximum calibrating watts for variousapplications and ratings.Minimum scale = CT ratio x PT ratio x minimum CW x KMaximum scale = CT ratio x PT ratio x maximum CW x KChoose a scale between the maximum and minimum. Orderby description, giving rating, transformer ratios, and choiceof scale.“PT Ratio x CT Ratio” is sometimes expressed as “TR”.Example: If CT Ratio is 400/5 and PT Ratio is 480/120; then TR = 320.4. See tables below for scale and legend keys to catalognumber (digits 12, 13, 14).
This table shows letter combinations assigned to end-scale values to be used for digits12 & 13 in Catalog number.
Key to Watt/Varmeter Legends This table shows letters assigned to inner scale legends to be used for digit 14 in Catalog number.
*For wattmeters that are to be used with phase shifting transformer for measuring vars.s Standard Legends AC Kilowatts/Kilovars and AC Megawatts/Megavars
............................................................................................................................................................................18
S W I T C H B O A R D I N S T R U M E N T S
PT PRIMARY VOLTAGE
CTScale Primary 240 480 600 2400 3600 4200 4800 6000 7200 12000 14400
Selection Current
Normal 25 10 20 25 100 150 175 200 250 300 500 600Max 15 30 35 150 200 250 300 350 450 750 900Min 8 16 20 80 120 150 160 200 250 400 500
Normal 50 20 40 50 200 300 350 400 500 600 1000 1200Max 30 60 75 300 450 500 600 750 900 1500 1750Min 16 35 40 160 250 300 350 400 500 800 1000
Normal 75 30 60 75 300 450 500 600 750 900 1500 1750Max 45 90 100 450 650 750 900 1000 1200 2000 2500Min 25 50 60 250 350 400 500 600 700 1200 1500
Normal 100 40 80 100 400 600 700 800 1000 1200 2000 2500Max 60 120 150 600 900 1000 1200 1500 1750 3000 3500Min 35 65 80 350 500 600 650 800 1000 1600 2000
Normal 150 60 120 150 600 1000 1000 1200 1500 1750 3000 3500Max 90 175 200 900 1200 1500 1750 2000 2500 4500 5000Min 50 100 100 500 700 800 1000 1200 1500 2500 3000
Normal 200 80 150 200 800 1200 1500 1500 2000 2500 4000 5000Max 120 200 300 1200 1750 2000 2000 3000 3500 6000 7000Min 65 125 160 650 1000 1200 1200 1600 2000 3500 4000
Normal 300 120 250 300 1200 1750 2000 2500 3000 3500 6000 7500Max 175 350 450 1750 2500 3000 3500 4500 5000 9000 10MwMin 100 200 250 1000 1500 1600 2000 2500 3000 5000 6000
Normal 400 150 300 400 1500 2500 3000 3000 4000 5000 8000 10MwMax 200 450 600 2000 3500 4000 4500 6000 7000 12Mw 14MwMin 120 250 350 1200 2000 2500 2500 3500 4000 6500 7500
Normal 600 250 500 600 2500 3500 4000 5000 6000 7500 12 15Max 350 700 900 3500 5000 6000 7000 9000 10Mw 17.5 20Min 200 400 500 2000 3000 3500 4000 5000 6000 10 12
Normal 800 300 600 800 3000 5000 5000 6000 8000 10Mw 15 20Max 450 900 1200 4500 7000 8000 9000 12Mw 12Mw 20 25Min 250 500 650 2500 4000 4500 5000 6500 7500 15 15
Normal 1200 500 1000 1200 5000 7500 8000 10Mw 12 15 25 30Max 700 1200 1750 7000 10Mw 12Mw 12Mw 17.5 20 35 45Min 400 750 1000 4000 6000 6500 7500 10 12 20 25
Normal 1500 600 1200 1500 6000 10Mw 10Mw 12 15 17.5 30 35Max 900 1750 2000 9000 12Mw 15Mw 17.5 20 25 45 50Min 500 1000 1000 5000 7000 8000 10 10 15 20 25
Normal 2000 800 1500 2000 8000 12 15 15 20 25 40 50Max 1200 2000 3000 12Mw 17.5 20 20 30 35 60 70Min 650 1400 1600 6500 10 12 12 16 20 35 40
Normal 3000 1200 2500 3000 12 17.5 20 25 30 35 60 75Max 1750 3500 4500 17.5 25 30 35 45 50 90 100Min 1000 2000 2500 10 15 16 20 25 30 50 60
Normal 4000 1500 3000 4000 15 25 30 30 40 50 80 100Max 2000 4500 6000 20 35 40 45 60 70 120 140Min 1200 2500 3500 12 20 25 25 35 40 65 75
Scale values for 3-wire / 3-phase (120 volts, 5 ampere) For 4-wire / 3-phase multiply by 2. For single-phase divide by 2. Note: PT Primary Voltages shown are the line to neutral valuefor 3-phase / 4-wire circuits.
TABLE ISelection of Wattmeter Scales(AB/DB-40/16 have a maximum of 4 digits as standard.)
Meg
awat
tsKi
low
atts
Scale Watts Formula:The limits of full-scale values depend upon the rating of the instru-ment and the current and potential transformer ratios used.In order to determine whether the desired full-scale value is withinlimits, the following calibrating-watts formula and table are used. Ifthe calibrating watts value falls within the range shown in the tablefor the instrument rating, the scale is acceptable.
Calibrating Watts/Element = Desired full-scale value in watts or varsCW (PT Ratio) x (CT Ratio) x K
STANDARD CALIBRATING WATT RANGES FOR 5A 120V RATING
ModelZero Left Zero Center ✳ s
or Center✳ Low Cal Watts
Watt or Var (except below) 380 — 760 190 — 7602 el. Var 10328 — & 103812 — 658 — 1316 329 — 131621⁄2 el. Var 10329 — & 103742 — 760 — 1520 380 — 1520* Other Voltage & current ratings will be proportionals End scale valuesNote 1: For 10329 and 103742 (21⁄2element varmeters only) Catalog Number Digits 8, 9, 10 are one-half (1⁄2) the CW ( ... calibration current) as calculated using K = 1.1547Note 2: The constant K may differ for various ”short-cut” methods of metering watts or vars.
s
s
Where K = 1 for 1-phase/2-wire circuitsK = 2 for 1-phase/3-wire, 2-phase/3-wire, 2-phase/4-wire, 3 phase/3-wire circuitsK = 4 for 3-phase/4-wire circuitsExcept K = 1.1547 for var models (10328 — & 103812 — 10329 — & 103742 — cross phase only)
............................................................................................................................................................................19
S W I T C H B O A R D I N S T R U M E N T S
TAB
LE I
IW
attm
eter
Sel
ecto
rFo
r 3-W
ire 3
-Ph
ase
(2-e
lem
en
t) W
att
mete
r 5A
120V
(Zero
-Left
)
C.T.
P.T.
RA
TIO
240/
120
480/
120
600/
120
2400
/120
3600
/120
4200
/120
4800
/120
6000
/120
7200
/120
1200
0/12
014
400/
120
(2:1
)(4
:1)
(5:1
)(2
0:1)
(30:
1)(3
5:1)
(40:
1)(5
0:1)
(60:
1)(1
00:1
)(1
20:1
)
25/5
RBU
7BA
CRB
U7B
GC
RBU
7BJC
RBU
7CA
CRB
U7C
ECRB
U7G
GC
RBU
7CG
CRB
U7C
JCRB
U7C
KCRB
U7C
RCRB
U7C
TC(5
:1)
10KW
20KW
25KW
100K
W15
0KW
175K
W20
0KW
250K
W30
0KW
500K
W60
0KW
50/5
RBU
7BG
CRB
U7B
NC
RBU
7BRC
RBU
7CG
CRB
U7C
KCRB
U7C
MC
RBU
7CN
CRB
U7C
RCRB
U7C
TCRB
U7D
AC
RBU
7DCC
(10:
1)20
KW40
KW50
KW20
0KW
300K
W35
0KW
400K
W50
0KW
600K
W10
00KW
1200
KW75
/5RB
U7B
KCRB
U7B
TCRB
U7B
XCRB
U7C
KCRB
U7C
PCXG
J7CR
CRB
U7C
TCRB
U7C
XCRB
U7C
ZCRB
U7D
ECRB
U7D
FC(1
5:1)
30KW
60KW
75KW
300K
W45
0KW
500K
W60
0KW
750K
W90
0KW
1500
KW18
00KW
100/
5RB
U7B
NC
RBU
7BYC
RBU
7CA
CRB
U7C
NC
RBU
7CTC
RBU
7CW
CRB
U7C
YCRB
U7D
AC
RBU
7DCC
RBU
7DG
CRB
U7D
HC
(20:
1)40
KW80
KW10
0KW
400K
W60
0KW
700K
W80
0KW
1000
KW12
00KW
2000
KW24
00KW
150/
5RB
U7B
TCRB
U7C
CCRB
U7C
ECRB
U7C
TCRB
U7C
ZCXG
J7D
AC
RBU
7DCC
RBU
7DEC
RBU
7DFC
RBU
7DKC
RAS7
DM
C(3
0:1)
60KW
120K
W15
0KW
600K
W90
0KW
1000
KW12
00KW
1500
KW18
00KW
3000
KW35
00KW
200/
5RB
U7B
YCRB
U7G
ECRB
U7C
GC
RBU
7CYC
RBU
7DCC
RBU
7DD
CRB
U7H
ECRB
U7D
GC
RBU
7DH
CRB
U7D
NC
RDR7
DRC
(40:
1)80
KW16
0KW
200K
W80
0KW
1200
KW14
00KW
1600
KW20
00KW
2400
KW40
00KW
5000
KW25
0/5
RBU
7CA
CRB
U7C
GC
RBU
7CJC
RBU
7DA
CRB
U7D
ECRB
U7H
GC
RBU
7DG
CRB
U7D
JCRB
U7D
KCRB
U7D
RCRB
U7D
TC(5
0:1)
100K
W20
0KW
250K
W10
00KW
1500
KW17
50KW
2000
KW25
00KW
3000
KW50
00KW
6000
KW30
0/5
RBU
7CCC
RBU
7CH
CRB
U7C
KCRB
U7D
CCRB
U7D
FCXG
J7D
GC
RBU
7DH
CRB
U7D
KCRA
S7D
MC
RBU
7DTC
RAS7
DW
C(6
0:1)
120K
W24
0KW
300K
W12
00KW
1800
KW20
00KW
2400
KW30
00KW
3500
KW60
00KW
7000
KW
400/
5RB
U7G
ECRB
U7C
LCRB
U7C
NC
RBU
7HEC
RBU
7DH
CRE
T7D
KCRB
U7D
LCRB
U7D
NC
RDR7
DRC
RBU
7DYC
RDR7
BAD
(80:
1)16
0KW
320K
W40
0KW
1600
KW24
00KW
3000
KW32
00KW
4000
KW50
00KW
8000
KW10
MW
500/
5RB
U7C
GC
RBU
7CN
CRB
U7C
RCRB
U7D
GC
RBU
7DKC
RBU
7DM
CRB
U7D
NC
RBU
7DRC
RBU
7DTC
RBU
7BA
DRB
U7B
CD(1
00:1
)20
0KW
400K
W50
0KW
2000
KW30
00KW
3500
KW40
00KW
5000
KW60
00KW
10M
W12
MW
600/
5RB
U7C
HC
RDR7
CRC
RBU
7CTC
RBU
7DH
CRA
S7D
MC
XGJ7
DN
CRD
R7D
RCRB
U7D
TCRA
S7D
WC
RBU
7BCD
RDR7
BED
(120
:1)
240K
W50
0KW
600K
W24
00KW
3500
KW40
00KW
5000
KW60
00KW
7000
KW12
MW
15M
W80
0/5
RBU
7CLC
XAG
7CTC
RBU
7CYC
RBU
7DLC
RDR7
DRC
RET7
DTC
XAG
7DTC
RBU
7DYC
RDR7
BAD
RBU
7FED
RDR7
BGD
(160
:1)
320K
W60
0KW
800K
W32
00KW
5000
KW60
00KW
6000
KW80
00KW
10M
W16
MW
20M
W
1000
/5RB
U7C
NC
RBU
7CYC
RBU
7DA
CRB
U7D
NC
RBU
7DTC
RBU
7DW
CRB
U7D
YCRB
U7B
AD
RBU
7BCD
RBU
7BG
DRB
U7B
HD
(200
:1)
400K
W80
0KW
1000
KW40
00KW
6000
KW70
00KW
8000
KW10
MW
12M
W20
MW
24M
W12
00/5
RDR7
CRC
RDR7
DA
CRB
U7D
CCRD
R7D
RCRA
S7D
WC
XGJ7
DYC
RDR7
BAD
RBU
7BCD
RDR7
BED
RBU
7BH
DRD
R7BK
D(2
40:1
)50
0KW
1000
KW12
00KW
5000
KW70
00KW
8000
KW10
KW12
MW
15M
W24
MW
30M
W15
00/5
RBU
7CTC
RBU
7DCC
RBU
7DEC
RBU
7DTC
RBU
7DZC
XGJ7
BAD
RBU
7BCD
RBU
7BED
RBU
7BFD
RBU
7BKD
RAS7
BMD
(300
:1)
600K
W12
00KW
1500
KW60
00KW
9000
KW10
MW
12M
W15
MW
18M
W30
MW
35M
W
2000
/5RB
U7C
YCRB
U7H
ECRB
U7D
GC
RBU
7DYC
RBU
7BCD
RBU
7BD
DRB
U7F
EDRB
U7B
GD
RBU
7BH
DRB
U7B
ND
RDR7
BRD
(400
:1)
800K
W16
00KW
2000
KW80
00KW
12M
W14
MW
16M
W20
MW
24M
W40
MW
50M
W25
00/5
RBU
7DA
CRB
U7D
GC
RBU
7DJC
RBU
7BA
DRB
U7B
EDRB
U7F
GD
RBU
7BG
DRB
U7B
JDRB
U7B
KDRB
U7B
RDRB
U7B
TD(5
00:1
)10
00KW
2000
KW25
00KW
10M
W15
MW
17.5
MW
20M
W25
MW
30M
W50
MW
60M
W30
00/5
RBU
7DCC
RBU
7DH
CRB
U7D
KCRB
U7B
CDRB
U7B
FDXG
J7BG
DRB
U7B
HD
RBU
7BKD
RAS7
BMD
RBU
7BTD
RAS7
BWD
(600
:1)
1200
KW24
00KW
3000
KW12
MW
18M
W20
MW
24M
W30
MW
35M
W60
MW
70M
W40
00/5
RBU
7HEC
RBU
7DLC
RBU
7DN
CRB
U7F
EDRB
U7B
HD
RET7
BKD
RBU
7BLD
RBU
7BN
DRD
R7BR
DRB
U7B
YDRD
R7CA
D(8
00:1
)16
00KW
3200
KW40
00KW
16M
W24
MW
30M
W32
MW
40M
W50
MW
80M
W10
0MW
5000
/5RB
U7D
GC
RBU
7DN
CRB
U7D
RCRB
U7B
GD
RBU
7BKD
RBU
7BM
DRB
U7B
ND
RBU
7BRD
RBU
7BTD
RBU
7CA
DRB
U7C
CD(1
000:
1)20
00KW
4000
KW50
00KW
20M
W30
MW
35M
W40
MW
50M
W60
MW
100M
W12
0MW
AB
-40
Cat
. No
. 103
221A
.....
Fin
d D
igit
s 8-
14 &
sca
le a
tA
B-1
6 C
at. N
o. 1
2122
1A...
..In
ters
ecti
on
of
C.T
. & P
.T. R
atio
s(F
or
zero
cen
ter
chan
ge
Dig
it 6
fro
m 1
to
2)
RATI
O
{
............................................................................................................................................................................20
S W I T C H B O A R D I N S T R U M E N T S
TAB
LE I
IIW
attm
eter
Sel
ecto
rFo
r 4-W
ire 3
-Ph
ase
(2
1 ⁄2-e
lem
en
t) W
att
mete
r 5A
120V
(Zero
-Left
)
C.T.
P.T.
RA
TIO
240/
120
480/
120
600/
120
2400
/120
3600
/120
4200
/120
4800
/120
6000
/120
7200
/120
1200
0/12
014
400/
120
(2:1
)(4
:1)
(5:1
)(2
0:1)
(30:
1)(3
5:1)
(40:
1)(5
0:1)
(60:
1)(1
00:1
)(1
20:1
)
25/5
RBU
7BG
CRB
U7B
NC
RBU
7BRC
RBU
7CG
CRB
U7C
KCRB
U7C
MC
RBU
7CN
CRB
U7C
RCRB
U7C
TCRB
U7D
AC
RBU
7DCC
(5:1
)20
KW40
KW50
KW20
0KW
300K
W35
0KW
400K
W50
0KW
600K
W10
00KW
1200
KW
50/5
RBU
7BN
CRB
U7B
YCRB
U7C
AC
RBU
7CN
CRB
U7C
TCRB
U7C
WC
RBU
7CYC
RBU
7DA
CRB
U7D
CCRB
U7D
GC
RBU
7DH
C(1
0:1)
40KW
80KW
100K
W40
0KW
600K
W70
0KW
800K
W10
00KW
1200
KW20
00KW
2400
KW75
/5RB
U7B
TCRB
U7C
CCRB
U7C
ECRB
U7C
TCRB
U7C
ZCXG
J7D
AC
RBU
7DCC
RBU
7DEC
RBU
7DFC
RBU
7DKC
RAS7
DM
C(1
5:1)
60KW
120K
W15
0KW
600K
W90
0KW
1000
KW12
00KW
1500
KW18
00KW
3000
KW35
00KW
100/
5RB
U7B
YCRB
U7G
ECRB
U7C
GC
RBU
7CYC
RBU
7DCC
RBU
7DD
CRB
U7H
ECRB
U7D
GC
RBU
7DH
CRB
U7D
NC
XAG
7DPC
(20:
1)80
KW16
0KW
200K
W80
0KW
1200
KW14
00KW
1600
KW20
00KW
2400
KW40
00KW
4500
KW15
0/5
RBU
7CCC
RBU
7CH
CRB
U7C
KCRB
U7D
CCRB
U7D
FCXG
JDG
CRB
U7D
HC
RBU
7DKC
RAS7
DM
CRB
U7D
TCRA
S7D
WC
(30:
1)12
0KW
240K
W30
0KW
1200
KW18
00KW
2000
KW24
00KW
3000
KW35
00KW
6000
KW70
00KW
200/
5RB
U7G
ECRB
U7C
LCRB
U7C
NC
RBU
7HEC
RBU
7DH
CU
CA7D
JCRB
U7D
LCRB
U7D
NC
XAG
7DPC
RBU
7DYC
XAG
7DZC
(40:
1)16
0KW
320K
W40
0KW
1600
KW24
00KW
2500
KW32
00KW
4000
KW45
00KW
8000
KW90
00KW
250/
5RB
U7C
GC
RBU
7CN
CRB
U7C
RCRB
U7D
GC
RBU
7DKC
RBU
7DM
CRB
U7D
NC
RBU
7DRC
RBU
7DTC
RBU
7BA
DRB
U7B
CD(5
0:1)
200K
W40
0KW
500K
W20
00KW
3000
KW35
00KW
4000
KW50
00KW
6000
KW10
MW
12M
W30
0/5
RBU
7CH
CXA
G7C
PCRB
U7C
TCRB
U7D
HC
RAS7
DM
CXG
J7D
NC
XAG
7DPC
RBU
7DTC
RAS7
DW
CRB
U7B
CDRA
S7BD
D(6
0:1)
240K
W45
0KW
600K
W24
00KW
3500
KW40
00KW
4500
KW60
00KW
7000
KW12
MW
14M
W
400/
5RB
U7C
LCXA
G7C
TCRB
U7C
YCRB
U7D
LCXA
G7D
PCU
CA7D
RCXA
G7D
TCRB
U7D
YCXA
G7D
ZCRB
U7F
EDXA
G7B
FD(8
0:1)
320K
W60
0KW
800K
W32
00KW
4500
KW50
00KW
6000
KW80
00KW
9000
KW16
MW
18M
W50
0/5
RBU
7CN
CRB
U7C
YCRB
U7D
AC
RBU
7DN
CRB
U7D
TCRB
U7D
WC
RBU
7DYC
RBU
7BA
DRB
U7B
CDRB
U7B
GD
RBU
7BH
D(1
00:1
)40
0KW
800K
W10
00KW
4000
KW60
00KW
7000
KW80
00KW
10M
W12
MW
20M
W24
MW
600/
5XA
G7C
PCXA
G7C
ZCRB
U7D
CCXA
G7D
PCRA
S7D
WC
XGJ7
DYC
XAG
7DZC
RBU
7BCD
RAS7
BDD
RBU
7BH
DTB
H7B
JD(1
20:1
)45
0KW
900K
W12
00KW
4500
KW70
00KW
8000
KW90
00KW
12M
W14
MW
24M
W25
MW
800/
5XA
G7C
TCXA
G7D
CCRB
U7H
ECXA
G7D
TCXA
G7D
ZCU
CA7B
AD
XAG
7BCD
RBU
7FED
XAG
7BFD
RBU
7BLD
UK
J7BM
D(1
60:1
)60
0KW
1200
KW16
00KW
6000
KW90
00KW
10M
W12
MW
16M
W18
MW
32M
W35
MW
1000
/5RB
U7C
YCRB
U7H
ECRB
U7D
GC
RBU
7DYC
RBU
7BCD
RBU
7BD
DRB
U7F
EDRB
U7B
GD
RBU
7BH
DRB
U7B
ND
XAG
7BPD
(200
:1)
800K
W16
00KW
2000
KW80
00KW
12M
W14
MW
16M
W20
MW
24M
W40
MW
45M
W12
00/5
XAG
7CZC
XAG
7DFC
RBU
7DH
CXA
G7D
ZCRA
S7BD
DXG
J7FE
DXA
G7B
FDRB
U7B
HD
TBH
7BJD
XAG
7BPD
TBH
7BRD
(240
:1)
900K
W18
00KW
2400
KW90
00KW
14M
W16
MW
18M
W24
MW
25M
W45
MW
50M
W15
00/5
RBU
7DCC
RBU
7DH
CRB
U7D
KCRB
U7B
CDRB
U7B
FDXG
J7BG
DRB
U7B
HD
RBU
7BKD
RAS7
BMD
RBU
7BTD
RAS7
BWD
(300
:1)
1200
KW24
00KW
3000
KW12
MW
18M
W20
MW
24M
W30
MW
35M
W60
MW
70M
W
2000
/5RB
U7H
ECRB
U7D
LCRB
U7D
NC
RBU
7FED
RBU
7BH
DU
CA7B
JDRB
U7B
LDRB
U7B
ND
XAG
7BPD
RBU
7BYD
XAG
7BZD
(400
:1)
1600
KW32
00KW
4000
KW16
MW
24M
W25
MW
32M
W40
MW
45M
W80
MW
90M
W25
00/5
RBU
7DG
CRB
U7D
NC
RBU
7DRC
RBU
7BG
DRB
U7B
KDRB
U7B
MD
RBU
7BN
DRB
U7B
RDRB
U7B
TDRB
U7C
AD
RBU
7CCD
(500
:1)
2000
KW40
00KW
5000
KW20
MW
30M
W35
MW
40M
W50
MW
60M
W10
0MW
120M
W30
00/5
RBU
7DH
CXA
G7D
PCRB
U7D
TCRB
U7B
HD
RAS7
BMD
XGJ7
BND
XAG
7BPD
RBU
7BTD
RAS7
BWD
RBU
7CCD
RAS7
CDD
(600
:1)
2400
KW45
00KW
6000
KW24
MW
35M
W40
MW
45M
W60
MW
70M
W12
0MW
140M
W40
00/5
RBU
7DLC
XAG
7DTC
RBU
7DYC
RBU
7BLD
XAG
7BPD
UCA
7BRD
XAG
7BTD
RBU
7BYD
XAG
7BZD
RBU
7GED
XAG
7CFD
(800
:1)
3200
KW60
00KW
8000
KW32
MW
45M
W50
MW
60M
W80
MW
90M
W16
0MW
180M
W50
00/5
RBU
7DN
CRB
U7D
YCRB
U7B
AD
RBU
7BN
DRB
U7B
TDRB
U7B
WD
RBU
7BYD
RBU
7CA
DRB
U7C
CDRB
U7C
GD
RBU
7CH
D(1
000:
1)40
00KW
8000
KW10
MW
40M
W60
MW
70M
W80
MW
100M
W12
0MW
200M
W24
0MW
AB
-40
Cat
. No
. 103
251A
.....
Fin
d D
igit
s 8-
14 &
sca
le a
tA
B-1
6 C
at. N
o. 1
2125
1A...
..In
ters
ecti
on
of
C.T
. & P
.T. R
atio
s(F
or
zero
cen
ter
chan
ge
Dig
it 6
fro
m 1
to
2)
RATI
O
{
............................................................................................................................................................................21
S W I T C H B O A R D I N S T R U M E N T S
TAB
LE I
VVar
met
er S
elec
tor
For
3-W
ire 3
-Ph
ase
(2-e
lem
en
t) V
arm
ete
r ra
ted
5A
120V
(Zero
-Cen
ter)
C.T.
P.T.
RA
TIO
240/
120
480/
120
600/
120
2400
/120
3600
/120
4200
/120
4800
/120
6000
/120
7200
/120
1200
0/12
014
400/
120
(2:1
)(4
:1)
(5:1
)(2
0:1)
(30:
1)(3
5:1)
(40:
1)(5
0:1)
(60:
1)(1
00:1
)(1
20:1
)
25/5
TAJ7
ARC
TAJ7
BAC
TAJ7
FCC
TAJ7
BRC
TAJ7
BXC
NKK
7BYC
TAJ7
CAC
TAJ7
GCC
TAJ7
CEC
TAJ7
CJC
TAJ7
CKC
(5:1
)5K
VAR
10KV
AR
12.5
KVA
R50
KVA
R75
KVA
R80
KVA
R10
0KVA
R12
5KVA
R15
0KVA
R25
0KVA
R30
0KVA
R
50/5
TAJ7
BAC
TAJ7
BGC
TAJ7
BJC
TAJ7
CAC
TAJ7
CEC
TAJ7
GG
CTA
J7CG
CTA
J7CJ
CTA
J7CK
CTA
J7CR
CTA
J7CT
C(1
0:1)
10KV
AR
20KV
AR
25KV
AR
100K
VAR
150K
VAR
175K
VAR
200K
VAR
250K
VAR
300K
VAR
500K
VAR
600K
VAR
75/5
TAJ7
BEC
TAJ7
BKC
WEK
7BN
CTA
J7CE
CW
EK7C
HC
RDH
7CJC
TAJ7
CKC
WEK
7CN
CTA
J7CP
CTA
J7CX
CTA
J7CZ
C(1
5:1)
15KV
AR
30KV
AR
40KV
AR
150K
VAR
240K
VAR
250K
VAR
300K
VAR
400K
VAR
450K
VAR
750K
VAR
900K
VAR
100/
5TA
J7BG
CTA
J7BN
CTA
J7BR
CTA
J7CG
CTA
J7CK
CTA
J7CM
CTA
J7CN
CTA
J7CR
CTA
J7CT
CTA
J7D
AC
TAJ7
DCC
(20:
1)20
KVA
R40
KVA
R50
KVA
R20
0KVA
R30
0KVA
R35
0KVA
R40
0KVA
R50
0KVA
R60
0KVA
R10
00KV
AR
1200
KVA
R15
0/5
TAJ7
BKC
TAJ7
BTC
TAJ7
BXC
TAJ7
CKC
TAJ7
CPC
RDH
7CRC
TAJ7
CTC
TAJ7
CXC
TAJ7
CZC
TAJ7
DEC
SAJ7
HG
C(3
0:1)
30KV
AR
60KV
AR
75KV
AR
300K
VAR
450K
VAR
500K
VAR
600K
VAR
750K
VAR
900K
VAR
1500
KVA
R17
50KV
AR
200/
5TA
J7BN
CTA
J7BY
CTA
J7CA
CTA
J7CN
CTA
J7CT
CTA
J7CW
CTA
J7CY
CTA
J7D
AC
TAJ7
DCC
TAJ7
DG
CU
FJ7D
JC(4
0:1)
40KV
AR
80KV
AR
100K
VAR
400K
VAR
600K
VAR
700K
VAR
800K
VAR
1000
KVA
R12
00KV
AR
2000
KVA
R25
00KV
AR
250/
5TA
J7BR
CTA
J7CA
CTA
J7G
CCTA
J7CR
CTA
J7CX
CN
KK7C
YCTA
J7D
AC
TAJ7
HCC
TAJ7
DED
TAJ7
DJC
TAJ7
DKC
(50:
1)50
KVA
R10
0KVA
R12
5KVA
R50
0KVA
R75
0KVA
R80
0KVA
R10
00KV
AR
1250
KVA
R15
00KV
AR
2500
KVA
R30
00KV
AR
300/
5TA
J7BT
CTA
J7CC
CTA
J7CE
CTA
J7CT
CTA
J7CZ
CRD
H7D
AC
TAJ7
DCC
TAJ7
DEC
SAJ7
HG
CTA
J7D
KCSA
J7D
MC
(60:
1)60
KVA
R12
0KVA
R15
0KVA
R60
0KVA
R90
0KVA
R10
00KV
AR
1200
KVA
R15
00KV
AR
1750
KVA
R30
00KV
AR
3500
KVA
R
400/
5TA
J7BY
CTA
J7G
ECTA
J7CG
CTA
J7CY
CTA
J7D
CCW
GG
7DEC
TAJ7
HEC
TAJ7
DG
CU
FJ7D
JCTA
J7D
NC
UFJ
7ARD
(80:
1)80
KVA
R16
0KVA
R20
0KVA
R80
0KVA
R12
00KV
AR
1500
KVA
R16
00KV
AR
2000
KVA
R25
00KV
AR
4000
KVA
R5M
VAR
500/
5TA
J7CA
CTA
J7CG
CTA
J7CJ
CTA
J7D
AC
TAJ7
DEC
TAJ7
HG
CTA
J7D
GC
TAJ7
DJC
TAJ7
DKC
TAJ7
ARD
TAJ7
ATD
(100
:1)
100K
VAR
200K
VAR
250K
VAR
1000
KVA
R15
00KV
AR
1750
KVA
R20
00KV
AR
2500
KVA
R30
00KV
AR
5MVA
R6M
VAR
600/
5TA
J7CC
CU
FJ7C
JCTA
J7CK
CTA
J7D
CCSA
J7H
GC
RDH
7DG
CTA
J7D
HC
TAJ7
DKC
SAJ7
DM
CTA
J7AT
DU
FJ7A
XD(1
20:1
)12
0KVA
R25
0KVA
R30
0KVA
R12
00KV
AR
1750
KVA
R20
00KV
AR
2400
KVA
R30
00KV
AR
3500
KVA
R6M
VAR
7.5M
VAR
800/
5TA
J7G
ECPJ
B7CK
CTA
J7CN
CTA
J7H
ECU
FJ7D
JCW
GG
7DKC
PJB7
DKC
TAJ7
DN
CU
FJ7A
RDTA
J7AY
DU
FJ7B
AD
(160
:1)
160K
VAR
300K
VAR
400K
VAR
1600
KVA
R25
00KV
AR
3000
KVA
R30
00KV
AR
4000
KVA
R5M
VAR
8MVA
R10
MVA
R
1000
/5TA
J7CG
CTA
J7CN
CTA
J7CR
CTA
J7D
GC
TAJ7
DKC
TAJ7
DM
CTA
J7D
NC
TAJ7
ARD
TAJ7
ATD
TAJ7
BAD
TAJ7
BCD
(200
:1)
200K
VAR
400K
VAR
500K
VAR
2000
KVA
R30
00KV
AR
3500
KVA
R40
00KV
AR
5MVA
R6M
VAR
10M
VAR
12M
VAR
1200
/5U
FJ7C
JCU
FJ7C
RCTA
J7CT
CU
FJ7D
JCSA
J7D
MC
RDH
7DN
CU
FJ7A
RDTA
J7AT
DU
FJ7A
XDTA
J7BC
DU
FJ7B
ED(2
40:1
)25
0KVA
R50
0KVA
R60
0KVA
R25
00KV
AR
3500
KVA
R40
00KV
AR
5MVA
R6M
VAR
7.5M
VAR
12M
VAR
15M
VAR
1500
/5TA
J7CK
CTA
J7CT
CTA
J7CX
CTA
J7D
KCTA
J7D
PCRD
H7A
RDTA
J7AT
DTA
J7A
XDTA
J7A
ZDTA
J7BE
DSA
J7FG
D(3
00:1
)30
0KVA
R60
0KVA
R75
0KVA
R30
00KV
AR
4500
KVA
R5M
VAR
6MVA
R7.
5MVA
R9M
VAR
15M
VAR
17.5
MVA
R
2000
/5TA
J7CN
CTA
J7CY
CTA
J7D
AC
TAJ7
DN
CTA
J7AT
DTA
J7A
WD
TAJ7
AYD
TAJ7
BAD
TAJ7
BCD
TAJ7
BGD
UFJ
7BJD
(400
:1)
400K
VAR
800K
VAR
1000
KVA
R40
00KV
AR
6MVA
R7M
VAR
8MVA
R10
MVA
R12
MVA
R20
MVA
R25
MVA
R25
00/5
TAJ7
CRC
TAJ7
DA
CTA
J7H
CCTA
J7A
RDTA
J7A
XDN
KK7A
YDTA
J7BA
DTA
J7FC
DTA
J7BE
DTA
J7BJ
DTA
J7BK
D(5
00:1
)50
0KVA
R10
00KV
AR
1250
KVA
R5M
VAR
7.5M
VAR
8MVA
R10
MVA
R12
.5M
VAR
15M
VAR
25M
VAR
30M
VAR
3000
/5TA
J7CT
CTA
J7D
CCTA
J7D
ECTA
J7AT
DTA
J7A
ZDRD
H7B
AD
TAJ7
BCD
TAJ7
BED
SAJ7
FGD
TAJ7
BKD
SAJ7
BMD
(600
:1)
600K
VAR
1200
KVA
R15
00KV
AR
6MVA
R9M
VAR
10M
VAR
12M
VAR
15M
VAR
17.5
MVA
R30
MVA
R35
MVA
R40
00/5
TAJ7
CYC
TAJ7
HEC
TAJ7
DG
CTA
J7AY
DTA
J7BC
DW
GG
7BED
TAJ7
FED
TAJ7
BGD
UFJ
7BJD
TAJ7
BND
UFJ
7BRD
(800
:1)
800K
VAR
1600
KVA
R20
00KV
AR
8MVA
R12
MVA
R15
MVA
R16
MVA
R20
MVA
R25
MVA
R40
MVA
R50
MVA
R50
00/5
TAJ7
DA
CTA
J7D
GC
TAJ7
DJC
TAJ7
BAD
TAJ7
BED
TAJ7
FGD
TAJ7
BGD
TAJ7
BJD
TAJ7
BKD
TAJ7
BRD
TAJ7
BTD
(100
0:1)
1000
KVA
R20
00KV
AR
2500
KVA
R10
MVA
R15
MVA
R17
.5M
VAR
20M
VAR
25M
VAR
30M
VAR
50M
VAR
60M
VAR
AB
-40
Cat
. No
. 103
812A
.....
Fin
d D
igit
s 8-
14 &
sca
le a
tA
B-1
6 C
at. N
o. 1
2181
2A...
..In
ters
ecti
on
of
C.T
. & P
.T. R
atio
s
RATI
O
{
............................................................................................................................................................................22
S W I T C H B O A R D I N S T R U M E N T S
TAB
LE V
Var
met
er S
elec
tor
(See
Note
s, P
age
3)Fo
r 4-W
ire 3
-Ph
ase
(2
1 ⁄2-e
lem
en
t) V
arm
ete
r ra
ted
5A
208V
(Zero
-Cen
ter)
C.T.
P.T.
RA
TIO
240/
120
480/
120
600/
120
2400
/120
3600
/120
4200
/120
4800
/120
6000
/120
7200
/120
1200
0/12
014
400/
120
(2:1
)(4
:1)
(5:1
)(2
0:1)
(30:
1)(3
5:1)
(40:
1)(5
0:1)
(60:
1)(1
00:1
)(1
20:1
)
25/5
AW
P7BA
CA
WP7
BGC
AW
P7BJ
CA
WP7
CAC
AW
P7CE
CA
WP7
GG
CA
WP7
CGC
AW
P7CJ
CA
WP7
CKC
AW
P7CR
CA
WP7
CTC
(5:1
)10
KVA
R20
KVA
R25
KVA
R10
0KVA
R15
0KVA
R17
5KVA
R20
0KVA
R25
0KVA
R30
0KVA
R50
0KVA
R60
0KVA
R
50/5
AW
P7BG
CA
WP7
BNC
AW
P7BR
CA
WP7
CGC
AW
P7CK
CA
WP7
CMC
AW
P7CN
CA
WP7
CRC
AW
P7CT
CA
WP7
DA
CA
WP7
DCC
(10:
1)20
KVA
R40
KVA
R50
KVA
R20
0KVA
R30
0KVA
R35
0KVA
R40
0KVA
R50
0KVA
R60
0KVA
R10
00KV
AR
1200
KVA
R75
/5A
WP7
BKC
AW
P7BT
CA
WP7
BXC
AW
P7CK
CA
WP7
CPC
KWE7
CRC
AW
P7CT
CA
WP7
CXC
AW
P7CZ
CA
WP7
DEC
AW
P7D
FC(1
5:1)
30KV
AR
60KV
AR
75KV
AR
300K
VAR
450K
VAR
500K
VAR
600K
VAR
750K
VAR
900K
VAR
1500
KVA
R18
00KV
AR
100/
5A
WP7
BNC
AW
P7BY
CA
WP7
CAC
AW
P7CN
CA
WP7
CTC
AW
P7CW
CA
WP7
CYC
AW
P7D
AC
AW
P7D
CCA
WP7
DG
CA
WP7
DH
C(2
0:1)
40KV
AR
80KV
AR
100K
VAR
400K
VAR
600K
VAR
700K
VAR
800K
VAR
1000
KVA
R12
000K
VAR
2000
KVA
R24
00KV
AR
150/
5A
WP7
BTC
AW
P7CC
CA
WP7
CEC
AW
P7CT
CA
WP7
CZC
KWE7
DA
CA
WP7
DCC
AW
P7D
ECA
WP7
DFC
AW
P7D
KCA
NS7
DM
C(3
0:1)
60KV
AR
120K
VAR
150K
VAR
600K
VAR
900K
VAR
1000
KVA
R12
00KV
AR
1500
KVA
R18
00KV
AR
3000
KVA
R35
00KV
AR
200/
5A
WP7
BYC
AW
P7G
ECA
WP7
CGC
AW
P7CY
CA
WP7
DCC
AW
P7D
DC
AW
P7H
ECA
WP7
DG
CA
WP7
DH
CA
WP7
DN
CKS
C7D
PC(4
0:1)
80KV
AR
160K
VAR
200K
VAR
800K
VAR
1200
KVA
R14
00KV
AR
1600
KVA
R20
00KV
AR
2400
KVA
R40
00KV
AR
4500
KVA
R25
0/5
AW
P7CA
CA
WP7
CGC
AW
P7CJ
CA
WP7
DA
CA
WP7
DEC
AW
P7H
CCA
WP7
DG
CA
WP7
DJC
AW
P7D
KCA
WP7
DRC
AW
P7D
TC(5
0:1)
100K
VAR
200K
VAR
250K
VAR
1000
KVA
R15
00KV
AR
1750
KVA
R20
00KV
AR
2500
KVA
R30
00KV
AR
5000
KVA
R60
00KV
AR
300/
5A
WP7
CCC
AW
P7CH
CA
WP7
CKC
AW
P7D
CCA
WP7
DFC
KWE7
DG
CA
WP7
DH
CA
WP7
DKC
AN
S7D
MC
AW
P7D
TCA
NS7
DW
C(6
0:1)
120K
VAR
240K
VAR
300K
VAR
1200
KVA
R18
00KV
AR
2000
KVA
R24
00KV
AR
3000
KVA
R35
00KV
AR
6000
KVA
R70
00KV
AR
400/
5A
WP7
GEC
AW
P7CL
CA
WP7
CNC
AW
P7H
ECA
WP7
DH
CJT
A7D
JCA
WP7
DLC
AW
P7D
NC
KSC7
DPC
AW
P7D
YCKS
C7D
ZC(8
0:1)
160K
VAR
320K
VAR
400K
VAR
1600
KVA
R24
00KV
AR
2500
KVA
R32
00KV
AR
4000
KVA
R45
00KV
AR
8000
KVA
R90
00KV
AR
500/
5A
WP7
CGC
AW
P7CN
CA
WP7
CRC
AW
P7D
GC
AW
P7D
KCA