Shirley Wound Drain: AN30 Andersen Tubes and Drains optimum drainage and tubes Dr Andersen first invented the Shirley Wound Drain, bilumenal tube, as a way to provide a simple, visual check that the tube is working correctly. “If it’s bubbling, it’s working!” A vented, bilumenal drainage tube designed to quickly aspirate the content of a fresh surgical wound. It is engineered to remove the blood oozing from the walls of the wound cavity before blood clots form. Features of the Shirley Wound Drain: the future of gas sterilisation Separate vent tube controls vacuum prevenng high sucon causing ssue damage. Burr free edges to aspirang ports prevents fibrin aachment and plugging. Round aspirang ports have slightly smaller diameter than the aspirang tube, so that parcles too large to pass through the aspirang tube are screened by aspirang ports. 24 aspirang ports; smaller percentage reducon in drainage if a port does become blocked. Vent tube is aached to aspirang tube by a slender web: maximises cross seconal area of aspirang tube, to outperform convenonal tubes many mes its size. 0.5 micron anbacterial filter prevents airborne contaminants from entering the system. Constant wash acon of bacteria-free air through the system removes blood from the tube long before it can clot and clog it. Soſt vinyl material reduces pressure necrosis. No latex, avoids allergic reacons. Phthalate free. Radio-opaque vent tube, allowing x-ray to confirm posioning. Clear aspirang tube allows posive visual evidence that the vacuum source and drain are working: “If it’s bubbling, it’s working.” Label covering yellow filter, prevents siphoning up the vacuum control tube before it is aached to an aspirator. Each drain is vacuum packed in two plasc envelopes. Ten of these are placed in an Andersen Sterijet package, vacuum-sealed and sterilised. A glance at the package gives visual confirmaon that it has not been damaged in handling. If it is vacuum-ght, it is sll sterile. The diameter of the aspirang port “A” is smaller than that of the aspirang tube “B”. Vent Tube Vent Tube Aspirang Tube Aspirang Tube ANDERSEN OTHER CROSS SECTION VIEW Size: 16 Fr. Length: 45cm Quanty: 10/box

Andersen Tubes and Drains · Andersen Tubes and Drains optimum drainage and tubes Dr Andersen first invented the Shirley Wound Drain, ... bilumenal drainage tube designed to quickly

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Andersen Tubes and Drains · Andersen Tubes and Drains optimum drainage and tubes Dr Andersen first invented the Shirley Wound Drain, ... bilumenal drainage tube designed to quickly

Shirley Wound Drain: AN30

Andersen Tubes and Drainsoptimum drainage and tubes

Dr Andersen first invented the Shirley Wound Drain,

bilumenal tube, as a way to provide a simple, visual check

that the tube is working correctly.

“If it’s bubbling, it’s working!”

A vented, bilumenal drainage tube designed to quickly

aspirate the content of a fresh surgical wound. It is

engineered to remove the blood oozing from the walls of

the wound cavity before blood clots form.

Features of the Shirley Wound Drain:

the future of gas sterilisation

Separate vent tube controls vacuum preventing high suction causing tissue damage.Burr free edges to aspirating ports prevents fibrin attachment and plugging.Round aspirating ports have slightly smaller diameter than the aspirating tube, so that particles too large to pass through the aspirating tube are screened by aspirating ports.24 aspirating ports; smaller percentage reduction in drainage if a port does become blocked.Vent tube is attached to aspirating tube by a slender web: maximises cross sectional area of aspirating tube, to outperform conventional tubes many times its size.0.5 micron antibacterial filter prevents airborne contaminants from entering the system.Constant wash action of bacteria-free air through the system removes blood from the tube long before it can clot and clog it.Soft vinyl material reduces pressure necrosis.No latex, avoids allergic reactions.Phthalate free.Radio-opaque vent tube, allowing x-ray to confirm positioning.Clear aspirating tube allows positive visual evidence that the vacuum source and drain are working: “If it’s bubbling, it’s working.”Label covering yellow filter, prevents siphoning up the vacuum control tube before it is attached to an aspirator.Each drain is vacuum packed in two plastic envelopes. Ten of these are placed in an Andersen Sterijet package, vacuum-sealed and sterilised. A glance at the package gives visual confirmation that it has not been damaged in handling. If it is vacuum-tight, it is still sterile.

The diameter of the aspirating port “A” is smaller than that of the aspirating tube “B”.

Vent TubeVent TubeAspirating TubeAspirating Tube

ANDERSEN OTHERCROSS SECTION VIEW

Size: 16 Fr.Length: 45cmQuantity: 10/box

•••

••

••

•••••

Page 2: Andersen Tubes and Drains · Andersen Tubes and Drains optimum drainage and tubes Dr Andersen first invented the Shirley Wound Drain, ... bilumenal drainage tube designed to quickly

Shirley Wound Drain Indications:

Placement of the Shirley Wound Drain:

the future of gas sterilisationRef:- Shirley Wound Drain Flyer 201602a

Shirley Wound Drain

Radical Neck Resection, Cholecystectomy, Open Reduction and Internal Fixation (Hip), Mastectomy, Miles Operation, Throidectomy, Colectomy, Gastrectomy, Appendectomy, and other surgical procedures where formation of haematoma might product complications.The Shirley Wound Drain operates with wall suction as well as electrically-operated vacuum aspirators standard to wound drainage.

As the vacuum increases in the aspirating tube, more air is drawn through the filter and down the vent tube. The vent tube helps prevent suction in the aspirating tube increasing to a level which damages tissue.

The vent tube is radio-opaque, but the aspirating tube is clear so that the aspirant is visible. If it’s bubbling, it’s working!

To place the Shirley Wound Drain, make a stab wound through the skin near the site to be drained. Push forceps out through the stab wound and grasp the tip of the drain. Draw the drain into the wound. Place the perforated tip of the drain in the most dependent part of the wound.

To suture the drain in place, pass a suture through the web between the two tubes. Tie the suture around the large tube and secure it to the skin.

As the wound is closed, initiate suction by connecting a compressed bulb syringe to the wound drain.

In the recovery room, remove bulb syringe and immediately connect collection container drain tube. A continuous suction device may be used. When suction had been established, remove the tab from the Shirley Wound Drain.

The cross-sectional rendering of the air vent tube reveals how air is filtered by a 0.5 micron antibacterial filter as it is drawn into the drain. Because of the pressure gradients designed into the system, the air is confined to the tube. No air enters the wound.