10
ESD flooring and covering 9 Which ESD-flooring do you need? A basic need for the floor is the resistance to ground R A . This should constitute less than 1 x 10 9 Ohm when measu- ring starts from the upper surface point of the flooring up to potential equalisation or ground terminal according to DIN EN 61340-5-1 (EBP). No ESDS has to be done on the flooring that’s why a lower limit is not quoted anymore. ESDS is transported in ESD cases or by persons who fulfill ESD requirements. If only ESD flooring/ESD shoes are used as grounding system, the resistance to ground including person, shoes and flooring has to amount < 3,5 x 10 7 Ohm. If a higher resistance is used for shoes or flooring systems, the resistance to ground has to be less than 1x 10 9 Ohm and the maximum voltage at a person does not fall below a limit of 100 V under worst case conditions. Are you working at open (i.e. easily accessible, tangible) dangerous voltages? YES: than you need a specific flooring which guarantees a minimized leakage resistance according to DIN VDE 0100-410 for persons safety of > 5 x 10 4 Ohm. The minimum value depends on the applied voltage. Only when using ESD shoes and flooring in combination they will work in an optimal manner – using only ESD shoes or only ESD flooring will show almost no effect… What is the "Walking Test” for? The new standard DIN EN 61340-4-5 (standard test method for particular applications – a procedure to characterize the electrostatic safety effect of shoes and flooring in combination with a person) describes a highly representative but also a very complex test to evaluate the static voltage of a person who moves on the test flooring. But the calculated data do only apply for a croncrete person including the specific shoe characteristics of this person. A generalisation means to make restrictions! Regulary test your ESD flooring! Particularly during wintertime the flooring should be checked about its discharge capacity. Often heavy variations of requirements and reality are detected in practice. This has various causes, which range from improper cleaners to false grounding and from improper materials ("antistatic flooring”) to lost conductivity when using coverings containing epoxy casting resin with fibres for discharging. You obtain a well-preserved flooring which is not – or not anymore dissipative? No problem. A long lasting, conductive and highly resistant top coat can be put on your floor with CANESOL ES II; CANESOL PV or POWERFLOOR. Throughout Europe the ESD-compatible laying of floors is possible by the CANESPA flooring team! Call us and together we`ll (almost) always find a solution. ? ! ? ! ? > Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

Embed Size (px)

Citation preview

Page 1: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD flooring and covering

9

Which ESD-flooring do you need?

A basic need for the floor is the resistance to ground RA. This should constitute less than 1 x 109 Ohm when measu-ring starts from the upper surface point of the flooring up to potential equalisation or ground terminal according toDIN EN 61340-5-1 (EBP).No ESDS has to be done on the flooring that’s why a lower limit is not quoted anymore. ESDS is transported in ESDcases or by persons who fulfill ESD requirements.

If only ESD flooring/ESD shoes are used as grounding system, the resistance to ground including person, shoes andflooring has to amount < 3,5 x 107 Ohm. If a higher resistance is used for shoes or flooring systems, the resistance toground has to be less than 1x 109 Ohm and the maximum voltage at a person does not fall below a limit of 100 Vunder worst case conditions.

Are you working at open (i.e. easily accessible, tangible) dangerous voltages?

YES:than you need a specific flooring which guarantees a minimized leakage resistance according to DIN VDE 0100-410for persons safety of > 5 x 104 Ohm.The minimum value depends on the applied voltage.

Only when using ESD shoes and flooring in combination they will work in an optimal

manner – using only ESD shoes or only ESD flooring will show almost no effect…

What is the "Walking Test” for?

The new standard DIN EN 61340-4-5 (standard test method for particular applications – a procedure to characterizethe electrostatic safety effect of shoes and flooring in combination with a person) describes a highly representative butalso a very complex test to evaluate the static voltage of a person who moves on the test flooring.

But the calculated data do only apply for a croncrete person including the specific shoe characteristics of this person.A generalisation means to make restrictions!

Regulary test your ESD flooring!

Particularly during wintertime the flooring should be checked about its discharge capacity. Often heavy variations ofrequirements and reality are detected in practice. This has various causes, which range from improper cleaners to falsegrounding and from improper materials ("antistatic flooring”) to lost conductivity when using coverings containingepoxy casting resin with fibres for discharging.

You obtain a well-preserved flooring which is not – or not anymore dissipative?

No problem. A long lasting, conductive and highly resistant top coat can be put on your floor with CANESOL ES II; CANESOL PV or POWERFLOOR.

Throughout Europe the ESD-compatible laying of floors is possible by the CANESPA flooring team! Call us and together we`ll (almost) always find a solution.

?

!

?

!

?

>

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 2: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD Industrial flooring POWERFLOOR

10

POWERFLOOR is a robust and long lasting industrial coating – also clean room approved – and fulfillsthe requirements according to DIN EN 61340-4-1 and to the new standard DIN EN 61340-4-5. Due toa ESD covering layer of 0.5 to 3 mm or even more the well-prised flooring remains long lasting and

resists forces properly.

Is your floor coating e.g. a carbon fibres coating system in a goodcondition but does not meet the required technical data?Not only suitable for new flooring but can also be used for recon-structing utilized floor coatings. Application without removal of theexisting coating is possible. In realtime even during the weekend.

Clean room approved

POWERFLOOR ESD system modules:- Epoxy resin priming coat- Epoxy resin conductive layer- Epoxy resin ESD final coating

Advantages of POWERFLOOR:

Reconstruction of utilized floor coatings Polishing and new covering layer

Economic, thick layers Thin and thick coating (self-spreading)Electrical features do not depend on the thickness of the coating

Humidity no influence, because of the consolidated punctual conductive synthetic, not aqueous and humidity resistant

Free from alkyl, nonylphenol, softening agent and is water-basedHighly abrasionproof

Suitable for clean rooms when hardend

(CANESPA ESD shoes on industrial flooring POWERFLOOR)

Specification Requirement Performance of POWERFLOOR

Electrostatic charging at persons"Walking Test" max. 100 Volt < 10 Volt *)DIN EN 61340-4-5 and 12% rel. humidityEOS/ESD-STM 97.2

System resistance"person-shoe-flooring” 7,5 x 105 …3,5 x 107 Ohm 1,6 … 3,8 x 106 Ohm *)DIN EN 61340-4-5 andEOS/ESD-STM 97.2

Resistance to groundDIN EN 61340-4-1 and < 109 Ohm 1 x 105 … 9,6 x 105 OhmANSI/ESD S 7.1 at 10V test voltages

*) depending on the types of shoes used for the test, in this case CANESPA ESD shoes

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 3: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

Electrostatics

7

Notes on the testing questions:

The questions are selected without any claim to be complete and without quality rating. Therefore the answering of these ques-

tions will only show a random sample of your ESD situation! Please answer the questions on a gut level, without long thinking and

without extenuation – the result is just for you not for any other persons.

The questioning form contains only "yes-questions”. If you can answer with yes – everything is allright.

If there is no "yes” you have the option to check or to let check of reliable authorities if and what amount of importance this

question does have on you and your associate partners.

Value levels are set by yourself, e.g.:

very = 5 normal = 3 less = 1 none = 0

and enable you to quantify your "NO"conclusions.

Interesting is also to include further employees when answering questions and analysing results. This extends the observasion hori-

zont and accidential occurrence is also excluded as well as the important is highlighted.

Packaging badge example: Device badge example:

* main function - badge

S (= shielding) shielding / shielding effect against electrostatic recharging

D (= dissipative) electrostatic conductive – resistance to ground ≥ 1 x 105 Ω und < 1 x 1011 ΩL (= low charging) marginal rechargeable (old term: antistatic)

C (= conductive) electrostatic conductive – resistance to ground ≥ 1 x 102 Ω und < 1 x 105 Ω

Questions (management related) How important is the question for you? Actual statusvery normal less none yes partly no

Are the ESD-measuring instruments (Tera-ohmmeter, field meter) available for the ESD co-ordinator?

Is there a conductive flooring in ESD protected areas and is the grounding characteristic proved?

Does anyone wear conductive shoes (ESD shoes) inside the ESD protected area?

Are there conductive desktops of tables, shelves, racks and so on?

Are there conductive transport carts used and checked frequently?

Are the ESDS and other protecting facilities as well as packaging clearly labeled?

Does anybody wear ESD clothes (smocks, shirts etc.)?

If packagings are opened while checked within stock receipt: Is there an ESD workstation seted up?

Do you influence the selection of cleaning agents especially floor cleaning agents utilized of cleaners within the EPA?

Do you have conductive chairs?

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 4: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD flooring

12

New: ESD- flooring POWER-CONNECT

POWER-CONNECT - a ESD flooring suitable for heavy load(suitable for forklifts tired with up to 5.0 t and elevating trucksup to1.5 t – depending on conditions). For easy floor laying andwhere you can step on right away. The flooring modules are

connected by a special invisible interlocking system shaped likea dove tail. Due to its unique assembly, electrial conductivity isguaranteed at a loosly laying for the first time.

Typical resistance to ground 105 to 106 Ohm DIN EN 61340-5-1Simple and easy floor laying at going concern smell absorbing and without any dustCan be stepped and drived on immediately after laying, heavy load approved*)Non-slip and comfortable to stand and walkReusableInvisible interlocking system – this way it can be heat–sealed, to meet highest hygenic requirementsEasy mechanical cleaning for economic maintenance

Load capacity: fork lift (air tired) up to 5.0 t – (firm tired) up to 2.5 t / elevating truck up to 1.5 tStatic: 50 kg/cm2 – dynamic: 90kg/cm2

Simple loose laying of the modules – even suitable for "problematic” grounding e.g. forreconstruction of:

Highly frequented areasAreas which are highly skid approved Rooms with high residual moisture Temporary rebuildingRaised and hole floors

Especially constructed galvanised ramp profiles ormade of V2A adjust the height of the border to thecovering thickness of 9.7 mm.

Makes loose laying on damaged, oily and ailing floors possible!

Flipside is equipped with honycomb structure- this makes laying on floors with highly residual

moisture possible, due to the achieved ventilation

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 5: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD flooring

13

New: ESD- flooring POWER-CONNECT

Order No: 30.129.10Colour: Montblanc grey

Other coulourson demand

Order No: 30.129.50Colour: Oasis beige

Order No: 30.129.30Colour: Kiwi green

Order No: 30.129.20Colour: Pacific blue

Order No: 30.129.40Colour: Gobi grey

POWER-CONNECT can be supplied in 5 standard colours:

Technical Data:

Dimensions of modules: 610 x 610 mm

Thickness: 9,7 mm

Weight per m2: approx. 11,5 kg

Weight per module: approx. 4,3 kg

Resistance to ground: ≤1 x 106 Ω , DIN EN 61340-5-1

Persons electric charging: < 100 Volt, DIN EN 61340-4-5

Anti-slid: R 9, DIN 51130

Fire resistance: Bfl – S1, EN 13501-1

Sound absorbing improvement: approx. 8 dB, EN 140-4/ISO 717-1

Recyclable: yes

Resistance to chemicals: highly resistant to acids, bases, oils, petrol, alcohol and terpentine substitute. Low resistance to other solvents as condiments (benzene), ester (ethyl acetate), ketones (acetone), chlorinated hydrocarbons.

Content of packaging: 5 modules (= 1,86 m2) per box

surface of Power-Connect

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 6: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

Electrostatic conductive "al” with double function

Coloured plastic covering with marbling

CANO CB is an electrostatic conductive plastic floor cove-ring with double function:

1. Resistance to ground of RA ≥ 106 - ≤ 108 Ohm accor-ding to DIN EN 61340-5-1 for an optimal protection ofcomponents and devices.

2. Minimum isolation for persons safety according to VDE 0100 part 610 (leakage resistance of > 5 x 104

Ohm).

The covering meets the fire protection requirements ofcategory B1 according to DIN 4102, part 1.

With smooth surface. CANPLAN EL II can be laied loosely -a conductive conglutination is not neccessary.

Floor Coverings

14

Floor Covering CANO CB

CANO CB is supplied in 9 standard colours:

CANO CB is supplied in 6 standard colours:

Order No: 30.120.55Colour No: 1205

Order No: 30.120.60Colour No: 1135

Order No: 30.120.65Colour No: 1125

Order No: 30.120.70Colour No: 1155

Order No: 30.120.85Colour No: 1175

Order No: 30.120.90Colour No: 1185

Order No: 30.120.75Colour No: 1145

Order No: 30.120.80Colour No: 1165

Order No: 30.120.95Colour No: 1195

Order No: 30.124.20Colour No: 794

Order No: 30.124.10Colour No: 790

Order No: 30.124.30Colour No: 793

Order No: 30.124.40Colour No: 795

Order No: 30.124.50Colour No: 791

Order No: 30.124.60Colour No: 792

CANO CB is an electrostatic conductive plastic floor coveringwith a resistance to ground of RA < 106 Ohm according toDIN EN 61340-5-1. The covering meets the fire protection

Floor Covering CANPLAN EL II

Thickness : ~ 2,0 mm

Dimensions: ~ 2 x 23 m

~ 610 x 610 mm

(also suitable for double bottom elements 600 x 600 mm)

14 = 5,21 m2 in a cardboard box

Thickness: ~ 2,0 mm

Dimensions: ~ 2 x 25 m

~ 610 x 610 mm

(also suitable for double bottom

elements 600 x 600 mm )

14 = 5,21 m2 in a cardboard box

requirements of the class B1 according DIN 4102, part1. Withsmooth surface. CANO CB can be laied loosely -a conducti-ve conglutination is not neccessary.

Electrostatic conductive "el”

Coloured plastic covering with marbling

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 7: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

Floor Coverings

15

Floor CoveringsCANPLAN CB 150

Electrostatic conductive "al” with dual purpose orElectrostatic conductive "el”.

CANPLAN CB 150 can be supplied in two versions:

SD-version with dual purpose:

1. resistance to ground of 106 ≤ RA ≤ 108 Ohm according to DIN EN 61340-5-1 to protect components and

devices optimally.

2. minimized electrical isolation for persons safety accor-ding to VDE 0100, part 610, 4 Ri > 5 x 104 Ohm

EC-version:

resistance to ground of RA 5 x 104 < R < 106 Ohm accordingto DIN EN 61340-5-1

Thickness: 2 mm

Dimensions: 610 x 610 mm

(also suitable for double bottom elements

600 x 600 mm)

The covering meets the fire protection requirements of

category B1 according to DIN 4102, part 1.

CANPLAN CB 150 is supplied in 6 standard colours

Electrically conductive flooring in an ESD-protected area

Colour: medium greyColour No: 205

Order No: Design

30.127.20 SD-version30.128.20 EC-version

Colour: light greyColour No: 201

Order No: Design

30.127.30 SD-version30.128.30 EC-version

Colour: brownish beigeColour No: 203

Order No: Design

30.127.40 SD-version30.128.40 EC-version

Colour: yellow beigeColour No: 229

Order No: Design

30.127.50 SD-version30.128.50 EC-version

Colour: blueColour No: 222

Order No: Design

30.127.60 SD-version30.128.60 EC-version

Colour: dark greyColour No: 207

Order No: Design

30.127.10 SD-version30.128.10 EC-version

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 8: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

Order No: Colour Colour No:30.100.96 dust grey 1065

ESD Flooring

16

CANESPA CB 412

CANESPA CB 412 NFPA

Electrostatic conductive "el".

Bicoloured caoutchouc covering in dot design.

The only light, electrostatic flooring made of caout-chouc has a smooth surface with a resistance to groundof RA < 106 Ohm according to EN 61340-5-1. Patentedcomposite structure.

Hardly inflammable B1 according to DIN 4102, part 1.

This floor covering can be laid loosley – a conductiveconglutination is not necessary.

CANESPA CB 412 is supplied in 5 standard colours

As special item also available in a version which meetsthe requirements of the NFPA (minimum quantity ondemand).

ESD flooring in an EPA zone.

Floor mat type BM 412Thickness: 2,5 mm

Dimensions: 1.200 x 2.000 mm

With 2 patent fasteners and 1 grounding cord

Order No: Colour Colour No:30.110.60 dust grey 1065

Tablemat type TM 412Thickness: 2,5 mm

Dimensions: 600 x 1.000 mm

With 2 patent fasteners and 1 grounding cord

Thickness: 2,5 mmDimensions: ~ 1,22 x 12 m

~ 610 x 610 mm

(also suitable for double bottom elements 600 x 600 mm)

12 = 4,44 m2 in a cardboard box

profile fitting dimensions: C + U

Order No: Colour Colour No:30.100.10 light grey 253

Order No: Colour Colour No:30.100.30 platin grey 0257

Order No: Colour Colour No:30.100.60 dust grey 1065

Order No: Colour Colour No:30.100.80 jade 1380

Order No: Colour Colour No:30.100.40 water blue 1382

5 years guarantee

for constant conductivity

5 years guarantee for the constan-cy of the indicated electric valuesaccording to our guarantee condi-tions (please request the condi-tions)

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 9: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD floor grid

17

ESD CANSTEP-Mat

ESD Floor grids, Anti-Fatigue Anti-skid

Material: nitrile cautchouc, conductive

Resistance to ground: ≤ 106 Ohm

Oil- and coolant-repellent

Structure: dome cell or smooth

Bottom side: knob profile

Thickness: 14 mm

Standard Dimension: 600 x 900 mm Flattened borders at all 4 sides

Special Dimensions: in (almost) any dimensionavailable on demand

Cross section through our ESD CANSTEP-mat with knobs Cross section through our ESD CANSTEP-mat with smooth surface

Order No: Design: Dimension:31.730.00 knob profile 600 x 900 x 14 mm31.731.00 smooth profile 600 x 900 x 14 mmOther dimensions on demand

Order No: Description: Dimension:32.500.00 floor grid 400 x 800 x 25 mm32.500.10 border grid 400 x 120 x 25 mm32.500.20 edge grid 120 x 120 x 25 mm

Material: polyethylene, conductive

Resistance to ground: ≤ 106 Ohm

Dimension: 400 x 800 x 25 mm – extendable

due to special interlocking system

The knop profile at the bottom side are constructed in such a

way that cables on the floor can be fixed safety.

Anti-skid and sound absorbing

Interlocking system

Bottom side:knob profile

Static dissipative Anti-Fatigue material, for use in EPA's with hard floors, anti-skid and shock absorbent, improves worker comfortand productivity

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78

Page 10: and... · Specification Requirement Performance of POWERFLOOR ... Colour: yellow beige Colour No: 229 " SD-version " EC-version Colour: blue

ESD ground marking tape and accessories

18

ESD ground marking tape D-STRIPE, extremely tearproofCan be used instead of colouring

Easy and fast to handle, can be driven on immediately

Easy to clean and removable residuelessly

Resistant to acids and bases, but not to solvents

Easy to clean with water and soap

Order No: Colour Width38.423.50 yellow 50 mm38.423.55 blue 50 mm38.423.56 red 50 mm38.423.57 white 50 mm38.423.58 green 50 mm38.423.60 yellow 75 mm38.423.70 yellow 100 mm

ESD ground marking tapeSuitable for any ESD area

Cupreous adhesive tape Self-adhesive

CANTRONAntistatic ESD floor cleaner

Material: PVCWidth: 50 mmLength: 33 mOrder No: 38.425.09

Length: 16,5 mWidth:: 9,0 mmThickness: 0,1 mmOrder No: 32.750.75

Length: 25 mWidth: 1000 mm

Order No: 31.800.00

1) 2)

3) 4)

5) 6)

ESD adhesive foil CANWAYSSuitable to fix floor coveringon used floors

Length: 30,5 mThickness: 1,4 mm

Note: Female e.g. is the the snap fastener onthe cable, male is the connection at the wristband. Order No: 26.850.50

CANTRON is an antistatic floor cleanersuitable for all ESD areas.

Order No: 32.760.00

Snap fastener circlip pliersSnap fastener

Order No: Size Fig. Type26.850.30 3 mm 1) female 26.850.35 3 mm 2) male 26.850.40 4 mm 3) female 26.850.45 4 mm 4) male26.850.10 10 mm 5) female26.850.15 10 mm 6) male

Content 10 Liter

Tel: +32 (0)3 230 19 75 www.esdproducts.eu Fax: +32 (0)3 230 19 78