ANALYTICS: BRINGING VALUE TO THE UTILITIES IN MITIGATING ENERGY LOSSES
José-Manuel LOPEZIstanbul, May 9, 2014
UTILITIES OPPORTUNITIES AND CHALLENGES
Leverage My AMI Investment
Improve Power Reliability &
Sustain Quality
Renewables & Distributed Generation
Growth
Energy Efficiency and
Demand Response
DATA INPUTS AND CLOSED LOOP ANALYTICS
AMI & MDM
SCADA
Weather / Other 3rd Party Sources
GIS
Billing & Work Management
Reports
Intelligence & Performance Dashboards
Scenarios & Prediction
Smart Grid Analytics Data
Warehouse
ITRON ANALYTICS
Smart Grid Analytics• Revenue Protection• Power Quality• Transformer Load Mgmt• DER Forecasting• Load Research• Energy Efficiency & DR• Dynamic Profiling• Financial Analytics• AMI Operations
Water & Gas Analytics• District Metering• Revenue Protection• Event Analysis• Conservation• Customer Service• Customer Portal• Distribution System
Monitoring
Consulting & Analysis• Advanced AMI Business
Case• Rate and Program
Design• Measurement and
Evaluation• Distributed Energy
Resources
CURRENT PRODUCTS
» Itron Analytics• Power Quality Analytics• Energy Diversion Detection• Transformer Load Management
ANALYTIC BUILDING BLOCKS
» Analytic Events combine meter exceptions, measurements, and/or other analytic events into useful objects
Single “Meter Removal Event”Begin Saturday 11:40am, duration 1hr 32 minutes
Pow
er D
own
Pow
er D
own
Pow
er U
pR
emov
al
Pow
er U
p
Pow
er U
p
Pow
er D
own
11:4
0am
1:12
pm
Time
Meter Removal
ANALYTIC BUILDING BLOCKS
» Combine analytic events and readings for more insight
kWh
Vo
ltag
e
Reduced Usage
Rem
oval
Rem
oval
Byp
ass
Inst
alle
d
Byp
ass
Rem
ove
d Time
Meter BypassEvent
ENERGY DIVERSION DETECTION
» Tamper reporting» Energy balance» Voltage/energy relationships» Work management/field investigation application interfaces
Itron Analytics
TAMPER ANALYSIS» Energy Diversion Detection
Priority Service Points
Tamper Events
Locations
Device Alerts
Date Range
Measurements
ENERGY BALANCE
» Secondary Energy Balancing• Compare
transformer measured energy to service points
» Primary Energy Balancing• Compare
upstream energy to downstream service points
» Report by magnitude or percent difference
Energy Diversion Detection
VOLTAGE/ENERGY PATTERNS
» Detect anomalies in
voltage/energy relationships
Energy Diversion Detection
APPLICATION BENEFITS
» Reduce energy delivery costs
• Conservation Voltage Reduction (CVR) opportunities
• Energy theft
» Increase power reliability and quality for utility customers
• Transformers at risk, proactively replace
• Outage scale, duration, and metrics
• Monitor low voltage conditions to take corrective action
» Support growth in distributed resources
• Actively monitor voltage across your network, forecast energy
» Expand and improve effectiveness of energy efficiency programs
• Identify inefficient users for targeted programs