11
Analysis Status of E05115 Chunhua Chen May 09, 2012

Analysis Status of E05115

  • Upload
    kamal

  • View
    47

  • Download
    0

Embed Size (px)

DESCRIPTION

Analysis Status of E05115. Chunhua Chen May 09, 2012. Old status. FWHM ~1.675MeV. σ = 0.529MeV. FWHM ~1.775MeV. I=20uA+35uA. σ = 0.529MeV. Problem: the optical description is not uniform on whole kinematical space 12 Λ Bgs resolution is worse compare to lambda and sigma; - PowerPoint PPT Presentation

Citation preview

Page 1: Analysis Status of E05115

Analysis Status of E05115Chunhua ChenMay 09, 2012

Page 2: Analysis Status of E05115

Old status

FWHM~1.775MeV

FWHM~1.675MeV

I=20uA+35uAσ= 0.529MeV

σ= 0.529MeV

Problem:the optical description is not uniform on whole kinematical space o 12

ΛBgs resolution is worse compare to lambda and sigma;o Core excited states does not shown up in 12

ΛB;

Page 3: Analysis Status of E05115

First Test-increase the weight of 12

ΛBgs-momentum tune-

σ= 403keVmm=-11.41

HMFW=1.84MeV

HMFW=1.80MeV

Page 4: Analysis Status of E05115

First Try-increase the weight of

12ΛBgs

-angle tune-

σ= 387keVmm=-11.38

HMFW=1.708MeV

HMFW=1.672MeV

Tips: Get the balance between momentum and angle for CH2

target Still Core excited states do not show up

Page 5: Analysis Status of E05115

Second Try-Put first core excites status into Mathematical tuning data sets with low statistical weight (w_core<=0.5w_bgs)

HMFW=1.90MeV

HMFW=1.84MeV

σ= 377keVmm=-11.36

Still Core excited states do not show up

Page 6: Analysis Status of E05115

Third Try-Put first core excites status into Mathematical tuning data sets with higher statistical weight(w_core=2w_bgs)

σ= 489keVmm=-11.42

HMFW=1.820MeV

HMFW=1.793MeV

Tips: Core excited states show up 12

ΛBgs becomes wider

Page 7: Analysis Status of E05115

Preliminary status – 10

ΛBeSecond Try

Third Try

Page 8: Analysis Status of E05115

Preliminary status – 9

ΛLi

KEK-E3369LBe

Page 9: Analysis Status of E05115

Preliminary Result 7ΛHe

E01011 data

E. Hiyama, et al., PRC53 2078 (1996)

n

n

6He core3/2+&5/2+

Page 10: Analysis Status of E05115

The optics is still not uniformly mathematically

described on whole kinematical space; Continue to do the optical and kinematical

tune; Think about the cross section and other

physics Prepare the thesis;

To do

Page 11: Analysis Status of E05115

Old status Problems-the optical description is not uniform on

whole kinematical space : o 12

ΛBgs resolution is worse compare to lambda and sigma;o Core excited states does not shown up in 12

ΛB; First try Status Second try Status Problem To do

Outline