2
FlexibiltyAnalysis Requirement for p Pipe OD (in) 4.5 2.32 Inches Feets e y X 52.29 4.3575 2.32 0.101094 Y 88.23 7.3525 2.32 0.170578 0.64857938 Z 319.41 26.6175 2.32 0.617526 FlexibiltyAnalysis Requirement NO Reference: B31.3 para# 319.4 Value of e Note: value of e will taken form B31.3 Appendix C-table C

Analysis Calculation by Junaid

Embed Size (px)

DESCRIPTION

tuberias

Citation preview

Page 1: Analysis Calculation by Junaid

FlexibiltyAnalysis Requirement for piping System

Pipe OD (in) 4.52.32

Inches Feets e ∆ y U LX 52.29 4.3575 2.32 0.101094Y 88.23 7.3525 2.32 0.170578 0.64857938 27.95600774 38.3275Z 319.41 26.6175 2.32 0.617526

FlexibiltyAnalysis Requirement NO

Reference: B31.3 para# 319.4

Value of e

Note: value of e will taken form B31.3 Appendix C-table C1

Page 2: Analysis Calculation by Junaid

Dy (L-U)² K<0.03

2.918607208 107.5678517 0.027132709