2
  PAGE 1 / 1 NAME: CONTRA INCENDIO (COINCA) C.A CERTIFICATE LAB0115-15 PLACE AND DATE OF INSPECTION: PUNTA CARDON, MARZO 30, 2015 COMPRESSOR DESCRIPTION BAUER HIGH PRESSURE BREATHING AIR COMPRESSOR MODEL / SERIAL K42-F3/460 V / 79273 AIR GRADE D (OSHA BREATHING AIR) SAMPLE PRESSURE 2000 PSI ANALISYS METHOD o MSA BREATHING AIR T EST KIT PN 491932 / SN 025570 USING MSA AUER OIL -HP TUBES, CO 2-HP TUBES 10-2000 PPM, CO TUBES 10-200 PPM, AND H2O-HP TUBES 5-70 PPM EXPIRING ON 04/2016 o OXYGEN ANALYSIS WITH RKI EAGLE MULTIGAS MONITOR SN E068031 / LAST CAL: 02/2015 COMPOUND STANDARD RESULTS TOTAL HYDROCARBONS < 25 PPM 0 PPM OXYGEN (19.5 23.5) % 20,9 % VOL +/- 0,5 % MOL CARBON MONOXIDE < 10 PPM 0 PPM CARBON DIOXIDE < 1000 PPM 200 PPM OIL < 5 mg / m 3  < 0.5 mg / m 3  HUMIDITY (H 2 O VAPORS) < 67 PPM 40 +/- 0,5 PPM NITROGEN NONE BALANCE ODOR NONE NONE REMARKS:  EXPANDED UNCERTAINTY FOR K=2  STANDARD FOR UNCERTAINTY IS NOT CONSIDERED FOR CARBON MONOXIDE ANALYSIS. RECOMMENDATIONS:  TO AVOID EXCESSIVE HUMIDITY ON BREATHING AIR FLOW, DRAIN THE COMPRESSOR MANUALLY BY THE INTER-STAGE OIL AND WATER SEPARATOR VALVES EVERY TEN MINUTES WHILE REFILLING.  REPLACE THE PURIFICATION CARTRIDGE EVERY 24-HOUR MAX. IN TROPICAL CLIMATE. THIS CERTIFICATED IS VALID FOR SIX MONTHS SINCE THE ISSUANCE DATE   ________________________________ SIGNATURE AND STAMP

Analisis Compresor Calidad del aire

Embed Size (px)

Citation preview

  • PAGE 1 / 1

    NAME: CONTRA INCENDIO (COINCA) C.A CERTIFICATE N LAB0115-15 PLACE AND DATE OF INSPECTION: PUNTA CARDON, MARZO 30, 2015

    COMPRESSOR DESCRIPTION BAUER HIGH PRESSURE BREATHING AIR COMPRESSOR

    MODEL / SERIAL N K42-F3/460 V / 79273

    AIR GRADE D (OSHA BREATHING AIR)

    SAMPLE PRESSURE 2000 PSI

    ANALISYS METHOD o MSA BREATHING AIR TEST KIT PN 491932 / SN 025570 USING MSA AUER OIL-HP TUBES, CO2-HP TUBES 10-2000

    PPM, CO TUBES 10-200 PPM, AND H2O-HP TUBES 5-70 PPM EXPIRING ON 04/2016 o OXYGEN ANALYSIS WITH RKI EAGLE MULTIGAS MONITOR SN E068031 / LAST CAL: 02/2015

    COMPOUND STANDARD RESULTS TOTAL HYDROCARBONS < 25 PPM 0 PPM

    OXYGEN (19.5 23.5) % 20,9 % VOL +/- 0,5 % MOL CARBON MONOXIDE < 10 PPM 0 PPM

    CARBON DIOXIDE < 1000 PPM 200 PPM OIL < 5 mg / m3 < 0.5 mg / m3

    HUMIDITY (H2O VAPORS) < 67 PPM 40 +/- 0,5 PPM NITROGEN NONE BALANCE

    ODOR NONE NONE REMARKS: EXPANDED UNCERTAINTY FOR K=2 STANDARD FOR UNCERTAINTY IS NOT CONSIDERED FOR CARBON MONOXIDE ANALYSIS.

    RECOMMENDATIONS: TO AVOID EXCESSIVE HUMIDITY ON BREATHING AIR FLOW, DRAIN THE COMPRESSOR MANUALLY BY THE

    INTER-STAGE OIL AND WATER SEPARATOR VALVES EVERY TEN MINUTES WHILE REFILLING. REPLACE THE PURIFICATION CARTRIDGE EVERY 24-HOUR MAX. IN TROPICAL CLIMATE.

    THIS CERTIFICATED IS VALID FOR SIX MONTHS SINCE THE ISSUANCE DATE

    ________________________________

    SIGNATURE AND STAMP