An Overview about the IECEx System Prof. Dr. Thorsten Arnhold IECEx Chairman 1 Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

An Overview aboutthe IECEx SystemProf. Dr. Thorsten ArnholdIECEx Chairman

1Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

Page 2: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx – building safe bridges for global business

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 2

Page 3: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 3

International Ex - business in the old times

Page 4: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 4

International Ex - business in the present

Page 5: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 5

International Ex - business in the future

Page 6: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IEC Family 164 countries – Global reach

82 Members 82 Affiliates

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

6

Page 7: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

The two pillars of the IEC building

Standard –

Generation

and

Maintenance

Assessment

Conformity

to relevant

Standards

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 7

Page 8: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IEC Structure for conformity assessment

IECEE

Conformity Assessment Board (CAB)

IECEx

IECQ

IECRE

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 8

Page 9: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

The IECEx vision remains unchanged since London 1996

Rules of procedure IECEx 02 Paragraph 5.6:The final objective of the IECEx – Certified EquipmentScheme is worldwide acceptance of one standard, one certificate and one mark.

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 9

Page 10: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx: Per July 2016 – 33 Member Countries

AustraliaBrazilCanadaChinaCroatiaCzech RepublicDenmarkFinlandFranceGermanyHungary

IndiaIsraelItalyJapanRepublic of KoreaMalaysiaNetherlandsNorwayNew ZealandPolandRomania

RussiaSingaporeSloveniaSouth AfricaSpainSwedenSwitzerlandTurkeyUnited Arab EmiratesUnited KingdomUnited States of America

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 10

Page 11: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Management Committee

„Parliament of IECEx“ administers the operation & reports to IEC CAB (2015 Christchurch New Zealand)Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

11

Page 12: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Important elements of the IECEx systemEx Testing Laboratory (ExTL):Directly or indirectly linked to a ExCBCarries out Type testIssues Test reports

Ex Certification Body (ExCB):Issues IECEx – CertificatesIssues Quality Assessment ReportsEndorses IECEx Test Reports

IECEx – AssessorAssessment of Ex CBsAssessment of Ex TLsBasis is ISO/IEC 17065(former ISO/IEC Guide 65)

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 12

Page 13: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx homepage: www.iecex.com

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 13

Page 14: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx consists of four schemes:

IECEx Conformity Mark License Scheme

IECEx Services SchemeCertification of Ex Service Providers, egRepair and overhaul workshops + Install.

IECEx Certified Persons Scheme (CoPC)Competency to work in Ex field (New)

IECEx Equipment SchemeCertification of Ex EquipmentIECEx Equipment SchemeCertification of Ex Equipment

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 14

Page 15: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Certified Equipment Scheme

IECEx “Certificate of Conformity”

IECEx “Unit Certificate”

IECEx “Component Certificate”

IECEx Equipment SchemeCertification of Ex Equipment + Systems

Site assessment of theManufacturers QM –System => QAR

Type Test => ExTR

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 15

Page 16: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Certified Equipment Scheme Certificates & Test Reports

0

5000

10000

15000

20000

25000

30000

2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 @ 21 June2016

Cumulative Growth of IECEx Equipment CoCs and Reports

CoCs

ExTRs

QARs

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 16

Page 17: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

The „fast track“ procedure

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 17

Page 18: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

For all EPL (a,b and c) there is an obligation to type tests/ ignition source analysis and site assessments of the QM systems carried outby IECEx CBs and TLs

Ignition risk analysis

New: IECEx conformity assessment for Non-electrical equipment

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 18

Page 19: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Draft OD 280: Guide to certification of non – electrical equipment

Risk analysis is evaluated by teams consisting of experts from the manufacturers and IECEx - Certification Bodies and Test Labs

If applicable and necessary type testsaed conducted by the IECEx - Test Labs

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 19

Page 20: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Draft OD 005-3-Part 3:Supplementary requirements for non-electrical…

ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality systems for equipment manufacturers is the basis documentAdditional requirements for the Quality Assurance during the manufacturing process of non – electrical components critical for the explosion protection of the equipment

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 20

Page 21: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Outlook

21

Page 22: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

ISO/IEC 800079 – 36 and -37 are published...

…international customers and regulators get the message soon

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 22

Page 23: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Consultants and Certification Bodies recognise the new business opportunities

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 23

Page 24: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Advertisement by the manufacturers

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 24

Page 25: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx consists of four schemes:

IECEx Conformity Mark License Scheme

IECEx Certified Persons Scheme (CoPC)Competency to work in Ex field (New)

IECEx Equipment SchemeCertification of Ex EquipmentIECEx Equipment SchemeCertification of Ex Equipment

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 25

IECEx Services SchemeCertification of Ex Service Providers, egRepair and overhaul workshops + Install.

Page 26: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Service Facility Scheme

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 26

Page 27: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Basic standard: IEC 60079-19 Repair & Overhaul

Basic question: Does the repair workshop fulfils the requirement of this standard? Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

27

Page 28: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IEC 60079 – 19 requires that the repair facility….

…operate a QM -system

…appoint a res-ponsible person

…have adequaterepair and overhaulfacilities

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 28

Page 29: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Certification procedure for IECEx repair facilities

Offsite & Site AssessmentCompliance With

IEC 60079-19 & OD315-5

Offsite & Site AssessmentQuality Management System

OD 314-5

Facility Assessment RecordFAR

IECExService Facility

Certificate of Competency

On-going SurveillanceOD 313-5

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 29

Page 30: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Service Facility Scheme

0

100

200

300

400

500

600

2009 2010 2011 2012 2013 2014 2015 @ 21 June2016

CoCs

FARs

Total

Drafts

Cumulative Number of CoCs and FARs for Repair facilities

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 30

Page 31: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Service Facility Scheme – next stepsEquipment Selection Installation & Initial Inspection

Inspection &Maintenance

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 31

Page 32: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx consists of four schemes:

IECEx Conformity Mark License Scheme

IECEx Services SchemeCertification of Ex Service Providers, egRepair and overhaul workshops + Install.

IECEx Certified Persons Scheme (CoPC)Competency to work in Ex field (New)

IECEx Equipment SchemeCertification of Ex EquipmentIECEx Equipment SchemeCertification of Ex Equipment

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 32

Page 33: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Lack of Competence in hazardous areas: some examples

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 33

Page 34: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Lack of Competence in hazardous areas:the consequences

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 34

Page 35: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

What is competence?

Knowledge

Acquired skills Tasks duties and responsibilities

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 35

Page 36: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Ex Units of competence

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 36

Page 37: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Appropriate Mix ofCompetences to becertified

Ex CB examines:

Skills

Experience

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 37

Certification Process

Page 38: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Combination of written & practical examination

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 38

Page 39: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECEx Certified Personal Scheme

0

200

400

600

800

1000

1200

1400

2010 2011 2012 2013 2014 2015 @ 21 June 2016

Certified Personnel Scheme - Cumulative Total

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

39

Page 40: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Recognized Training Providers RTP

40Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

Page 41: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017 41

Page 42: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

IECExCertificates & Test Reports

0

10000

20000

30000

40000

50000

60000

70000

2014 2015 Apr 16 E 2016

39342

48062

58109

70000

Absolut von 2014 - 2016

42Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017

+ 45%48062

Page 43: An Overview about the IECEx System · Draft OD 005-3-Part 3: Supplementary requirements for non-electrical… ISO/IEC 80079 – 34: Explosive atmospheres-Part 34:Application of quality

43Prof. Dr. Thorsten Arnhold | The IEC Ex System | IECEx Conference Shanghai 2017