3
EMAX Aspiration Catheter An efficient and effective solution for thrombus removal Available in 5 F and 6 F

An efficient and effective solution for thrombus removal · The EMAX is designed to provide an efficient and effective solution for thrombus removal. Offering excellent trackability,

Embed Size (px)

Citation preview

EMAX™ Aspiration Catheter

An efficient and effective solution for thrombus removal

Available in 5 F and 6 F

The EMAX is designed to provide an efficient and effective solution for thrombus removal. Offering excellent trackability, pushability, and aspiration volume.

DELIVERY SYSTEM• Pre-loaded Stylet provides improved pushability and kink resistance, ensuring

optimal catheter delivery in tortuous paths

• Smooth Catheter provides excellent flexibility and lumenal volume

• Hydrophilic Coating allows for easy navigation through tortuous anatomy

ASPIRATION VOLUME• Large Extraction Lumen due to shaft construction, ensures optimal aspiration rates

• Short Tip Design for deliverability and increased safety during aspiration procedure

• Large Aspiration Port allows for a higher rate of aspiration and increased aspiration volume

55.5”141 cm

2.95”7.5 cm

55.5”141 cm

2.95”7.5 cm

55.11”140 cm

Port

Port

5 F

Stylet

6 F

0.189”4.8 mm

Above measurements are taken with a guidewire in parallel to the aspiration catheter

EMAX™

Aspiration Catheter

5 F Catheter Extraction Area: 0.54 mm2 6 F Catheter Extraction Area: 0.95 mm2

Guidewire Lumen

Aspiration Lumen

0.021”0.53 mm

OD 0.57 mm x ID 0.42 mm

OD 1.37 mm x ID 1.10 mm

Guidewire Lumen

Aspiration Lumen

0.01”0.26 mm

OD 0.57 mm x ID 0.42 mm

OD 1.06 mm x ID 0.83 mm

OD 0.022” x ID 0.017”

OD 0.054” x ID 0.043”

OD 0.022” x ID 0.017”

OD 0.042” x ID 0.033”5 F 6 F

Catalog Number

Compatible Guide Catheter

Compatible Guidewire

Outer Profile Suction LumenRX

LengthAspiration

PortEffective Length

DistalProximal

(Shaft + Parallel Guidewire)

Distal Proximal

VX5HI55 F

(min. ID 0.058”)(min. ID 1.47 mm)

0.014”0.36 mm

≤ 3.2 F≤ 0.042”

≤ 1.067 mm

4.44 F0.058”

1.48 mm

0.78 F0.010”

0.26 mm

2.51 F0.033”

0.838 mm

2.95”75 mm

0.189” 4.8 mm

55.5” 141 cm

VX6HI56 F

(min. ID 0.070”)(min. ID 1.78 mm)

0.014”0.36 mm

≤ 4.11 F≤ 0.054”

≤ 1.37 mm

5.34 F0.070”

1.78 mm

1.59 F0.021”

0.53 mm

3.30 F0.043”

1.10 mm

2.95”75 mm

0.189” 4.8 mm

55.5” 141 cm

TsunaMEDManufacturer: QualiMed Innovative Medizinprodukte GmbHBoschstraße 1621423 Winsen, GermanyPH: +49 4171 6578 0 FX: +49 4171 6578 11

Indications / Contraindications Indications: The EMAX Aspiration Catheter is indicated for the removal of thrombus and debris in the coronary or peripheral arteries by percutaneous suction.

Contraindications: The EMAX Aspiration Catheter is contraindicated for use in the following areas:

1. Single use only. Do not re-sterilize and/or re-use.2. These components are contraindicated in the following

lesions: • Left main trunk lesion unprotected by bypass graft or

collateral circulation. • The venous system.3. These components are contraindicated in the following

patients: • Patients who are responsive to surgical treatment • Patients with lateral distal stenosis of the stent

installed at the bifurcated lesion. • Patients with serious blood coagulation abnormality.4. The EMAX Aspiration Catheter is contraindicated in the

removal of fibrous, adherent or calcified material.

Product Specifications Platform 5 F and 6 F Thrombosis Aspiration Catheter CoatingHydrophilic coating present on distal shaft 260 mm (10.23”)

Strain Relief GuardProvides ease of pushability and prevents kinking

Rapid Exchange Segment75 mm (2.95”)

New Advanced Proximal Shaft CatheterSupports tortuous anatomy - 300 mm strengthening of the proximal tube for more proximal stiffness

Radiopaque Marker BandDistance Tip to marker 3.5 mm (0.14”)

Guidewire Compatibility0.36 mm (0.014”)

Working Catheter Length141 cm (55.5”)

Regulatory Status CE Mark Approved

Components Included • 30 ml polycarbonate locking syringes (x2)• Extension line with stopcock (x1)• 40 µm filter basket (x1)

BRO_EMAX REV. B

The EMAX Aspiration Catheter is a rapid exchange type catheter used for the removal of thrombus and debris in the coronary or peripheral arteries via percutaneous suction.

EMAX™ Aspiration Catheter

EMAX (through the lumen) vs Competitors*Pushability 5 F / 6 F

44%

44%

41%

40%

40%

27%

Pushability quotient [%]

EMAX 6 F

EMAX 5 F

Merit Medical ASAP 6 F

Medtronic Export AP 6 F

Vascular Pronto V3 6 F

Terumo Eliminate 6 F

0% 10 20 30 40 50 60 70 80 90 100%

BETTER

* Data on �le at QualiMed