AUTO - SCANNING WITH DIGITAL CONTROLLCD COLOR MEDICAL MONITOR
AMM15TK3 / AMM15TK3-TE / AMM15TK3-TEWOperation Manual
For future reference, record the serial number of your displaymonitor in the space below :
Serial Number
The serial number is located on the back of the monitor
back of the monitor
ADVAN INT’L CORP.2007“ELO” is a Registered trademark of Elo TouchSystems, Inc.,All other trademarks are the property of their reference owners.This document is subject to change without notice.Advan provides this information as reference only. Reference to other vendor’sproducts does not imply any recommendation or endorsement.
Revision Control
GNINRAW
fosresuehtmrofniotdesusi"GNINRAW"eltitehTro,htaed,yrujniehttcilfnidluoctahtsesuacelbissop
.stneitapehtotegamadytreporp
NOITUAC
fosresuehtmrofniotdesusi"NOITUAC"eltitehThguohtlastneitapehttcilfnidluoctahtsesuacelbissop
.shtaedesuacothguoneerevestonthgimti
ETON
smetifosresuehtmrofniotdesusi"ETON"eltitehT,noitallatsnifosmretniecnatropmifoerataht
hguohtlatnempiuqEehtfoecnanetniamro,noitarepoehtotmrahylidobehttcilfnitonseoderuliafeht
.stneitap
etaD noitpircseD
701150C.veR rebmuntnemucoD
AMM15TK3 1
TABLE OF CONTENTS
Product Description and Intended Use......................................................Warnings and Cautions................................................................................Symbol Explanations....................................................................................EU Declaration of Conformity for Medical Applications...........................Safety Precaution.........................................................................................Cleaning Your Monitor..................................................................................Power Management Function....................................................................Preset Modes..............................................................................................DDC.............................................................................................................Installation....................................................................................................Connecting the Power Cord......................................................................Component / RGB / RGBS Connection Instruction.................................User Controls..............................................................................................OSD Screen Basic Section.......................................................................OSD Function Description.........................................................................Troubleshooting..........................................................................................Specification of (AMM15TK3)..................................................................Classification..............................................................................................Electromagnetic Compatibility..................................................................Dimension Drawing (mm)..........................................................................Connectors..................................................................................................Description of Warranty..............................................................................Tounchscreen User’s Manual....................................................................
3 4 7 8 9 91011121213141516192021222326272830
2 User’s Guide
Product Description and Intended UsePlease check the following items are present when you unpack the box, and save thepacking materials in case you will need to ship or transport the monitor in future.• AMM15TK3 LCD Monitor and two video cable (1) DVI-A to HD15 VGA cable*
(1) DVI-D cable* (1) BNC to RCA adapter (1) DVI-A to BNC Female cable*
• AC Power cord ***
• AC-Adapter
• Composite Video BNC Jack Cable and Super Video Cable
• User Manual
*Might be optional item, check with local representative**Touchscreen Data Cable and Floppy Disk (Touchscreen driver) optional***Might vary pending on region standard
CAUTIONManufacturer : Ault KoreaModel No : MW160KA1203F52
*
*
*
AMM15TK3 3
Warnings and CautionsPlease read this manual and follow its instructions carefully. The words warning,caution, and note carry special meanings and should be carefully reviewed:
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, andperformance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusivelyby ADVAN Int’l Corp.• The electrical installation of the relevant operating room complies with theapplicable IEC and CE requirements.
Warning Federal law (United States of America) restricts this device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM15TK3 monitor has been tested under UL 60601-1standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s)described herein. Product(s), therefore, may not agree in detail to the publisheddesign or specifications. All specifications are subject to change without notice.Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp salesrepresentative or agent for information on changes and new products.
ebyamnaicisyhprotneitapehtfoytefaslanosrepehTgninraWnitluserdluocnoitamrofnisihtgnidragersiD.devlovni
.naicisyhprotneitapehtotyrujni
ebtsumsnoituacerproserudecorpecivreslaicepSnoituaC.tnemurtsniehtgnigamaddiovaotdewollof
etoN tnatropmiroreisaeecnanetniamekamotnoitamrofnilaicepS.raelceromnoitamrofni
ehttrelaotdednetnisielgnairtanihtiwkramnoitamalcxenAecnanetniamdnagnitarepotnatropmifoecneserpehtotresu
.tcudorpehtgniynapmoccaerutaretilehtnisnoitcurtsni
ehtfonrawotdednetnisielgnairtanihtiwtlobgninthgilAdezirohtuaotecivresllarefeR.egatlovsuodrazahfoecneserp
.lennosrep
RESUEHTOTYRUJNISUOIRESLAITNETOPDIOVAOTgninraW,ECIVEDSIHTOTEGAMADRO/DNATNEITAPEHTDNA
:TSUMRESUEHT
4 User’s Guide
Warnings1. Read the operating manual thoroughly and be familiar with its contents prior to usingthis equipment.2. Carefully unpack the unit and check if any damage occurred during shipment.3. Should any solid object or liquid fall into the panel, unplug the unit and have it checkedby qualified personnel before operating it any further.4. Uplug the unit if it is not to be used for an extended period of time. To disconnect thecord, pull it out by the plug. Never pull the cord itself.5. Be a qualified physician, having complete knowledge of the use of this equipment.6. Test this equipment prior to a medical procedure. This monitor was fully tested at thefactory before shipment.7. Avoid removing covers on control unit to avoid electric shock.8. Attempt no internal repairs or adjustments not specifically detailed in this operatingmanual.9. Pay close attention to the care, cleaning instructions in this manual. A deviation maycause damage (refer to the Cleaning section).10. DO NOT STERILIZE MONITOR.11. Read the entire instruction manual before assembling or connecting the camera.12. Do not place the monitor or any other heavy object on the power cord. Damage to thecable can cause fire or electirc shock.13. Monitor with power supply is suitable for use in patient environment.14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devicesin IEC 601-1-2:2003. These limits are designed to provide reasonable protection againstharmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions, may cause harmful interference toother devices in the vicinity. However, there is no guarantee that interference will not occurin a particular installation. If this equipment does cause harmful interference to otherdevices, which can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving device.- Increase the separation between the equipment.- Connect the equipment into an outlet on a circuit different from that to which the otherdevice(s) are connected.- Consult the manufacturer or field service technician for help.
NOTICES TO USERThis device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation.
FCC WARNINGThis equipement generates or uses radio frequency energy. Changes or modifications tothis equipment may cause harmful interference unless the modifications are expresslyapproved in the instruction manual. The user could lose the authority to operate thisequipment if an unauthorized change or modification is made.
AMM15TK3 5
Cautions1. The AC Adapter must be plugged into a Grounded power outlet.2. Use only the proprietary AMM15TK3 power supply for the AMM15TK3 monitor. Make aproper connection by ensuring that the shrink tubing completely secures the connectionbetween the DC power cord and the extension cord.3. Turn power off when unit is not in use.4. Never operate the unit right after having transported from a cold location directly to awarm location.5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to thescreen. Spray the cleaning solution into a soft cloth and clean gently.6. Handle the monitor with care. Do not strike or scratch the screen.7. Do not block the monitor cooling vents. The monitor is cooled by natural convectionand has no fan.8. Do not force the monitor past 28 degrees of vertical when adjusting the screenposition. (For monitors equipped with stands only.)9. Remove the power module and connection when transporting the unit.10. Save the original carton and associated packing material. They will be useful shouldyou have to transport or ship the unit.11. Allow adequate air circulation to prevent internal heat buildup.12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,draperies) that may block the ventilation slots.13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.14. The unit is designed for operation in a horizontal position. Never operate the unit in avertical position.15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)16. Do not expose the monitor to moisture or excessive dust.17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/orIEC 60601-1-1 harmonized national standard or the combination should be evaluated.Do not touch the patient with signal input or output connectors.18. Use only a hospital grade power supply cord.19. This equipment generates, uses, and can radiate radio frequency energy. If notinstalled correctly and or not used in accordance with these instructions, it may causeharmful interference with other devices. This may be determined by turning theequipment off and on. The user is encouraged to try to correct the interference throughone or more of the following measures:• Reorient or relocate the receiving device.• Increase the separation distance between the equipment.• Connect the equipment to an outlet on a circuit different from that to which the otherdevice(s) are connected.• Consult the manufacturer or field service technican for help.20. Grounding reliability can only be achieved when the equipment is connected to anequipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note To connect to an international power supply, use a an attachment plugappropriate for the power outlet.
Note Refer to the “Electromagnetic Compatibility” (EMC) section of this manual toensure EMC. The AMM15TK3 must be installed and operated according to the EMCinformation provided in this manual.
6 User’s Guide
Symbol DefinitionsAMM15TK3 7
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample ofthis document may be found in the addendum which accompanied thismanual. For a copy of the Declaration of Conformity document, pleasecontact ADVAN Int’l Corp. and request for AMM15TK3 DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. Youneed a stable and level surface near a grounded wall outlet in an areawhich is relatively free of glare from sunlight or other sources of brightlight. The monitor is cooled by natural convection (it has no fan).For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents forshipping damage that could cause a fire or shock hazard. Immediatelyreport any shipping damage to the carrier or transportation companyand contact customer service for monitor in the future or in case ofreturn.
After you unpack the monitor, make sure the following items are in-cluded
• Monitor with video cable
• AC adapter with cable CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter Manufacturer: Ault korea Model No: MW160KA1203F52
• Touchscreen cable if monitor has touchscreen option
• This operations manual
Note: Your system provider may offer alternative cords or cablesdepending on the installation requirement and local geography issues.
8 User’s Guide
SAFETY PRECAUTION· Avoid placing the monitor, or any other heavy object, on the power cord to prevent
fire or electrical shock from damage to the power cord.· Do not expose the monitor to rain, excessive moisture, or dust to avoid fire or shock
hazard.· Do not cover the slots or openings of the monitor for proper heat dissipation. Always
put the monitor in a place where there is adequate ventilation.· Avoid placing the monitor against a bright background or where sunlight or other
light sources may reflect on the area of the monitor. Place the monitor just beloweye level.
· Handle with care when transporting the monitor.· Refrain from giving the shock or scratch to the screen, as screen is fragile.
CLEANING YOUR MONITORNo specific liquid or chemical necessary when cleaning this LCD monitorHowever, we suggest to clean the monitor with non-abrasive cloths and cleaningsolutions used in hospitals to clean similar equipment. We recommend using 70%Isopropyl alcohol for the screen surface and warm water and a mild detergent for allother surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol • 6% aqueous ammonia • Cidex (2.4% glutaraldehyde solution) • Sodium Hypochlorite (bleach) 10% • “Green soap” USP • 0.5% Chlorhexidine in 70% isopropyl alcohol • Ovation • Formula 409 • Fantastic • Wex CideTo clean the screen, do not spray liquid cleaners directly on to the unit. Stand awayForm the monitor and spray cleaning solution onto a cloth. Without applying exces-sive pressure, clean the screen with the slightly dampened rag.
AMM15TK3 9
POWER MANAGEMENT FUNCTIONThe monitor is equipped with the power management function which automatically reducethe power consumption when not in use in three power level modes.
• Stand-by ModeThe monitor goes into stand-by mode when the horizontal sync signal is off forabout 10 seconds. In this mode, the screen goes off and the power LED blinks for 1seconds On and 1 second Off. The screen is displayed after the horizontal syncsignal is restored.
• Suspend ModeThe monitor goes into suspend mode when the vertical sync signal is off for about10 seconds. The power consumption during this is less than 8 W. In this mode, thescreen goes off and the power LED blinks for 1 seconds On and 1 second Off. Thescreen is displayed after the vertical sync signal is restored.
• Off ModeThe monitor goes into power-off mode when the vertical and horizontal sync signalsare off for about 10 seconds. In this mode, the screen goes off and the power LEDblinks for 1 seconds On and 1 second Off. The screen is displayed after the verticaland horizontal sync signals are restored.
Power Management System
The AMM15TK3 Medical Monitor power management proposal. Provides four phasesof power-saving modes by detecting the horizontal sync signal as shown in the tableblow.
When the monitor is power saving mode or detects an incorrect timing, the screen willbe blank and power LED indicator will blink.
edoM rewoPtupnICD)ylnorotinom(
rewoptupnICA)retpadaCA.lcnI(
sutatSDEL
nO .xamW83 .xamW06 neerGydaetS
ybdnatS .xamW0.6 .xamW5.7 neerGgniknilB
dnepuS .xamW0.6 .xamW5.7 neerGgniknilB
ffO .xamW0.6 .xamW5.7 neerGgniknilB
10 User’s Guide
PRESET MODES
edoM )VxH(noituloseR )zHK(.qerF.H )zH(.qerF.V
1 053x046 5.13 07
2 053x046 9.73 58
3 004x046 9.73 58
4 053x027 5.13 07
5 004x027 9.73 58
6 084x046 5.13 06
7 084x046 9.73 27
8 084x046 5.73 57
9 084x046 3.34 58
01 006x008 1.53 65
11 006x008 9.73 06
21 006x008 1.84 27
31 006x008 9.64 57
41 006x008 7.35 58
51 867x4201 5.53 34
61 867x4201 4.84 06
71 867x4201 5.65 07
81 867x4201 06 57
91 867x4201 7.86 58
02 468x2511 5.76 57
12 069x0821 06 06
22 4201x0821 9.36 06
32 4201x0821 97 57
*Best resolution 1024 x 768, 60 Hz
AMM15TK3 11
DDCTo make your installation easier, the monitor is able to Plug and Play with your systemif your system also supports DDC protocol. The DDC (Display Data Channel) is acommunication protocol through which the monitor automatically informs the host systemabout its capabilities, for example, supported resolutions and corresponding timing. Themonitor supports DDC1 and DDC2B standard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:Steps1. Use the supplied video cable (DVI, DVI-A->VGA, S-Video, C-Video, DVI-A->BNC
Female) then connect to the host system accordingly.2. Connect the DC power to the DC power connector on the monitor.3. Connect one end of AC power cord into the AC Adapter and the other end to AC power outlet.4. Then turn the host system on and then the monitor.5. If the monitor still does not function properly, please refer to the troubleshooting section to diagnose the problem.
POWER DVI -I(VGA/COMPONENT)
S-V C-V TOUCH SCREEN (OPTION)
12 User’s Guide
CONNECTING the POWER CORD
* Check first to make sure that the power cord you use is the correct type required foryour area.
* This monitor has an universal AC adapter that allows operation in either AC 100 - 240V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper ACoutlet.
The cord set should have the appropriate safety approvals for the country in which theequipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMAconfiguration 5-15P type (parallel blades) plug cap. For 240 volt applications use onlyUL Listed Detachable power supply cord with NEMA configuration 6-15P type (tandemblades) plug cap.
AMM15TK3 13
Component / RGB / RGBS CONNECTION INSTRUCTIONFor Component (YPbPr) Connection1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.2. Connect BNC (YPbPr) cables from the video source to the DVI-A to BNC Female cable. Red (Pr) connect to Red BNC, Green (Y) connect to Green BNC, and Blue (Pb)connect to Blue BNC.3. The video source should have components output on the video equipment for components (YPbPr) video out.4. To select component mode in the monitor, push “Select” button on the monitor until it reach “Component / RGB” input or can select in the OSD by Push “Up Arrow” button then the OSD Menu will pop-up, Push “Up Arrow” or “Down Arrow” button to select “Input Source Select” then push select button to enter Input Source Select Menu, Push “Up Arrow” or “Down Arrow” button to select “Component / RGB” then push select button.
For RGB Connection1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.2. Connect BNC (RGB) cables from the video source to the DVI-A to BNC Female cable. Red (R) connect to Red BNC, Green (G) connect to Green BNC, and Blue (B)connect to Blue BNC.3. The video source should have RGB output on the video equipment for RGB video out.4. To select RGB mode in the monitor, push “Select” button on the monitor until it reach “Component / RGB” input or can select in the OSD by Push “Up Arrow” button then the OSD Menu will pop-up, Push “Up Arrow” or “Down Arrow” button to select “Input Source Select” then push select button to enter Input Source Select Menu, Push “Up Arrow” or “Down Arrow” button to select “Component/RGB” then push select button.
For RGBSync Connection1. Connect DVI-A to BNC Female cable onto the monitor via DVI port.2. Connect BNC (RGB) cables from the video source to the DVI-A to BNC Female cable. Red (R) connect to Red BNC, Green (G) connect to Green BNC, Blue (B)connect to Blue BNC and SYNC (V) connect to White BNC.3. The video source should have RGBSync output on the video equipment for RGBS video out.4. To select RGBSync mode in the monitor, push “Select” button on the monitor until it reach “Component / RGB” input or can select in the OSD by Push “Up Arrow” button then the OSD Menu will pop-up, Push “Up Arrow” or “Down Arrow” button to select “Input Source Select” then push select button to enter Input Source Select Menu, Push “Up Arrow” or “Down Arrow” button to select “Component / RGB” then push select button.
14 User’s Guide
USER CONTROLS
Front Panel Controls
1. Power LED : Lights up to indicate the power is turned ON.2. Power Switch : To turn ON or OFF the power.3. + : To increase the value of the parameter in the OSD you have selected for adjustment. : To increase the contrast directly when OSD menu is not activated. : To move upward in the OSD menu. : Execute a function of selected item.4. - : To decrease the value of the parameter in the OSD you have selected for adjustment. : To decrease the brightness directly when OSD menu is not activated. : To move downward in the OSD menu.5. Menu : To enter OSD.6. Select : Enter a sub menu or select a menu item.
If video display option is adopted, switch PC display to Video display andvice versa by one touch when OSD menu is not activated.
7. Auto Button : One touch Auto adjust or Exit OSD menu.
Standard OSD Operation
1. Press “Menu” button to activate the OSD.2. Use “+” or “-” button to move through the menu.
The parameter will be highlighted when selected.3. Then use “Select” button to enter the sub menu.
Choice the sub menu different options with “Select” button.3. Then use “+” or “-” to increase or decrease the value of the parameter, or makeselection between different options.4. To quit the OSD screen at any time during the operation, press “Auto” button.
If no keys are pressed for a time period, the OSD automatically disappears.
AMM15TK3 15
OSD Screen Basic Section
#1 Only available when you using the (VGA) or (Component / RGB) connection* Follow the Standard OSD Operation.Use “-” or “+” button to adjust
16 User’s Guide
Brightness / Contrast * Frequency / Phase * (#1)
Position * OSD Control *
Color Temperature * Utilities *
OSD Screen Basic SectionAMM15TK3 17
Hue and Saturation * (#2) Sharpness * (#2)
Zoom * Input Source Select *
Scale Mode * (#3) Scale Mode * (#4)
#2 Only available when you using the (C-Video) or (S-Video) connection#3 Only available when you using the (VGA) or (DVI) connection#4 Only available when you using the (C-Video), (S-Video) or (Component/RGB) connection* Follow the Standard OSD Operation.Use “-” or “+” button to adjust
OSD Screen Basic Section18 User’s Guide
Auto Adjust / Factory Reset * (#5) Factory Reset * (#6)
Information (#7)
#5 Only available when you using the (VGA) connection#6 Only available when you using the (DVI), (C-Video), (S-Video) or (Component/RGB)connection#7 Different video input may have different information* Follow the Standard OSD Operation.Use “-” or “+” button to adjust
AMM15TK3 19
OSD Function Description
(#1) Only available when you using the (C-Video), (S-Video) connection(#2) Only available when you using the (VGA) or (Component / RGB) connection(#3) Only available when you using the (VGA) or (DVI) connection(#4) Only available when you using the (C-Video), (S-Video) or (Component / RGB) connection(#5) Only available when you using the (VGA) connection
metI noitpircseDnoitcnuF
ssenthgirB .ssenthgirbehtesaercedroesaercnioT
tsartnoC .tsartnocehtesaercedroesaercnioT
euH .leveleuhehtesaercedroesaercnioT )1#(
noitarutaS .levelnoitarutasehtesaercedroesaercnioT )1#(
ycneuqerF .)kcolctod(ycneuqerftsujdaoT )2#(
esahP .)esahp-kcolc(esahptsujdaoT )2#(
latnoziroH .thgirrotfelneercsehtevomoT
lacitreV .drawnwodrodrawpuneercsehtevomoT
soProHDSO .thgirrotfelunemDSOevomoT
soPreVDSO .drawnwodrodrawpuunemDSOevomoT
dnuorgkcaBDSO .tneculsnarTroeuqapOneewtebesoohC
tuoemiTresU .emitgniraeppaneercsDSOteS
kcoLyeK 5gnirudyek"thgiR+uneM"dloh&sserP(,noitcnufkcoLyeKelbanE.)elbasidrofsdnoces
pmeTroloC metsyS,2metsyS,1metsyS,39D,56D,tluaufeDneewtebesoohC.pmetroloc4metsySro3
deR .deRecnalaB
neerG .neerGecnalaB
eulB .eulBecnalaB
ammaG ,8.1,hparGoidaR,0S,4.2foegnarhtiwtnemtsujdaammaGesoohC.3.2,2.2,1.2,0.2,9.1
SMPD .SMPDelbasiDroelbanE
tceleSecruoSotuA noitcelesecruosotuaelbasiDroelbanE
emarFezeerF .emarfezeerfelbasiDroelbanE
mooZ .noitcnufni-moozelbanE
ssenprahS .ssenprahsoedivehtesaercedroesaercnioT )1#(
edoMelacS otenoro,oitartcepsa,neercsllifneewtebedomelacsoedivesoohC.eno )3#(
edoMelacS .ediwroenooteno,lamronneewtebedomelacsoedivesoohC )4#(
tceleSecruoStupnI etisopmoC,BGRlatigiD,BGRgolanAneewtebecruostupniesoohC.BGR/tnenopmoCrooedivrepuS,oediv
tsujdAotuA ,noitisop-H,noitisop-VtsujdayllacitamotualliwtsujdA-otuAehT5tuobasekatssecorpelohweht,tsartnoCdna,esahP-kcolCDCLdehcattaehtnielifnrettaptsetehtesuesaelP(.sdnoces
.)tsujdAotuArofksidytiliturotinom )5#(
yrotcaFllaceRtluafeD
.tluafedyrotcafotteS
noitamofnI .edomtupnidna,etarhserfer,noitulosernonoitamrofniyalpsiD
20 User’s Guide
TROUBLESHOOTINGBefore sending your LCD monitor for servicing, please check the troubleshooting listbelow to see if you can self-diagnose the problem.
smelborP sutatStnerruC ydemeR
oNerutciP
NODEL • ottsartnocdnassenthgirbtsujda,DSOgnisU.sgnittestluafedriehtotteserromumixam
FFODEL • .hctiwsrewopehtkcehC
• ylreporpsidrocrewopCAfikcehC.retpadaCAehtotdetcennoc
gniknilBDEL • ylreporpsielbaclangisoedivfikcehC.rotinomfokcabehttadetcennoc
• .NOsimetsysretupmocotrewopehtfikcehC
lamronbAerutciP
erutciPelbatsnU • retpadascihpargfonoitacificepsehtfikcehCebyamhcihwecnailpmocnisirotinomdna.hctamsimycneuqerflangistupniehtgnisuac
siyalpsiDretnec,gnissim
llamsootro,tfihsniegralootro
ezisyalpsid
• yalpsidllitsfi,nottubputeSotuAgnisU,KCOLCtsujdanehterutciplamronba-VdnaNOITISOP-H,ESAHP-KCOLC
.slangisdradnats-nonhtiwNOITISOP
• neercs-llufgnissimfoesacni,DSOgnisUruoyninoituloserrehtotcelesesaelp,egami
ro)TN,89/59swodniW(metsySgnitarepO.gnimithserferlacitrevrehto
• gnitsujdaretfasdnoceswefaroftiawtsuMrognignahcerofebegamiehtfoeziseht
ehtFFOgnirewoprolangisehtgnitcennocsid.rotinom
* Require use of DVI-A to 5 BNC Adapter Cable** All contents are subject to change without notice.** Surface Wave Touchscreen model -TEW and Resistive Touchscreen model -TE
SPECIFICATION3KT51MMA
lenaPDCL enaPTFTroloChcni-51/mc83
epyT xirtaMevitcA
noituloseR )dednemmoceR(senil867xstod4201
hctiPlexiP mm792.0
roloCyalpsiD srolocnoillim61
emiTesnopseR ).pyT(sm52
retliFroloC epytepirtslacitrevBGR
gnihsiniFecaF detaoCdraHeralG-itnA
elgnAgniweiV )01=>RC(V°071H°071
oediV 1xzHM561latigiD)kniLlenaP(SDMT&BGRgolanap-pV7.0
langiStupnI
cnyS cnysdetarapesp-pV0.5~5.2
)golanA(ecnadepmItupnI mhO57-oediVmhOk1-cnyS
latigiD dengila-BSMtib42lexipelgnis,reviecerSDMTlennahc3
ycneuqerFgninnacS
latnoziroH zHk8.97~74.13
lacitreV zH58~05
eziSyalpsiD
VxH )mm822xmm403("9x"21
selacSyarG,oitdaRtsartnoC,ssenthgirB
ssenthgirB ).pyT(2m/dc053,)WET-3KT51MMA(2m/dc513WAS:noitpOneercShcuoT
)ET-3KT51MMA(2m/dc082evitsiseR
oitaRtsartnoC ).pyT(1:006
rotcennoCtupnIlangiS
oediV ,*)rPbPY(tnenopmoC,oediV-S,oediV-C,I-IVDgolanA/latigiD*cnySBGR,*BsGR
neercshcuoT )lanoitpO(9-BD232-SR
tnemnorivnEerutarepmeT
erutarepmeTgnitarepO )C°04-°01(F°401~°05
erutarepmeTegarotS )C°06-°02-(F°041~°4-
ytidimuHgnitarepO )noitasnednoctuohtiw(HR%57~03
erusserPcirehpsomtAgnitarepO aPh0601~007
ecruoSrewoP
rotinoMyalpsiD V21CD
retpadA-CA lamroN,noitpotuohtiW(%01-/+W72V042~001CA)noitarepO
snoitalugeR
latnemnorivnE&IME,ytefaS ,ICCV,BC,CCF,EC,2-1-10606NE,1-10606NE,1-10606LUSHoR,CCC
tenibaC
tnuoMeerF )D(hcni5.2x)H(hcni6.21x)W(hcni7.51)D(mm46x)H(mm023x)W(mm993
thgieW
tnuoMeerF dradnatS)gK4.3(sbl5.7neercShcuoThtiw)gK7.4(sbl5.01
eludoMlanoitpO
dnatSesaB,lenaPhcuoT
AMM15TK3 21
22 User’s Guide
This monitor is intended for use in Health Care Facilities model AMM15TK3
Equipment is not suitable for use in the presence of flammable anesthetic mixturewith air or with oxygen or nitrous oxide.
No user serviceable parts inside, ask qualified personnel when accessing inside.
For disposal of waste product, follow the requirement of local code.
Electrical input rating: 12V DC 3.5A
Classification
Type of protection against electric shock: Class I Equipment.
Degree of protection against the ingress of water: IPX1 compliance.
Mode of operation: Continuous
This monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2 andis certified by UL to medical standard UL60601-1(UL/cUL Mark).
Because many medical offices are located in residential areas, this monitor, inaddition to the medical requirements, has also been tested and found to comply withthe limits for FCC Class B computing devices in a typically configured system. It isthe system integrator or configurer’s responsibility to test and ensure that the entiresystem complies with applicable EMC laws.
Environmental conditions for transport and storage:- Temperature range within -4° to 140° F (-20° to 60° C)- Relative humidity range within 10% to 90%- Atmospheric pressure range within 500 to 1060 hPa.
51LJMedical EquipmentE215822
Electromagnetic CompatibilityLike other electrical medical equipment, the AMM15TK3 requires special
precautions to ensure electromagnetic compatibility with other electrical medicaldevices. To ensure electromagnetic compatibility (EMC), the AMM15TK3 must beinstalled and operated according to the EMC information provided in this manual.
Note The AMM15TK3 has been designed and tested to comply with IEC 60601-1-2:2001 requirements for EMC with other devices.
Caution Portable and mobile RF communications equipment may affectthe normal function of the AMM15TK3.
Warning Do not use cables or accessories other than those providedwith the AMM15TK3, as this may result in increased electromagnetic emissionsor decreased immunity to such emissions.
Warning If the AMM15TK3 is used adjacent to or stacked with otherequipment, observe and verify normal operation of the AMM15TK3 in theconfiguration in which it will be used prior to using it in a surgical procedure.Consult the tables below for guidance in placing the AMM15TK3.
snoissimEcitengamortcelE:noitaralceDs'rerutcafunaMdnaecnadiuG
deificepstnemnorivnecitengamortceleehtniesurofdednetnisi3KT51MMAnidesusititahterusnedluohs3KT51MMAforesuehtroremotsucehT.woleb
.tnemnorivnenahcus
11RPSICsnoissimeFR 1puorG
ygreneFRsesu3KT51MMA;noitcnuflanretnistirofylnosnoissimeFRsti,erofereht
toneradnawolyreveraynaesuacotylekil
ybraenniecnerefretni.tnempiuqecinortcele
11RPSICsnoissimeFR BssalCrofelbatiussi3KT51MMA,stnemhsilbatsellaniesu
citsemodgnidulcniesohtdnastnemhsilbatseehtotdetcennocyltceridrewopegatlov-wolcilbupseilppustahtkrowtenylppuscitsemodrofdesusgnidliub
sesoprup
snoissimecinomraH2-3-00016CEI AssalC
rekcilf/snoitautculFegatloV3-3-00016CEIsnoissime seilpmoC
AMM15TK3 23
24 User’s GuideytinummIcitengamortcelE:noitaralceDs'rerutcafunaMdnaecnadiuG
resuehtroremotsucehT.wolebdeificepstnemnorivnecitengamortceleehtniesurofdednetnisi3KT51MMA.tnemnorivnenahcusnidesusititahterusnedluohs3KT51MMAfo
tseTytinummI leveLtseT10606CEI leveLecnailpmoC citengamortcelE
egrahcsiDcitatsortcelE2-4-00016CEI)DSE(
tcatnocVk6±riaVk8±
tcatnocVk6,4,2±riaVk8,4,2±
,doowebdluohssroolFfI.elitcimarecro,etercnoc
htiwderevocerasroolfeht,lairetamcitehtnys
taebdluohsytidimuhevitaler.%03tsael
tsrub!tneisnarttsaflacirtcelE4-4-00016CEI
senilylppusrewoprofVk2±seniltuptuo/tupnirofVk1±
dnuorgotenilVk2±enilotenilVk1±
dluohsytilauqrewopsniaMlacipytafotahteb
latipsohrolaicremmoc.tnemnorivne
5-4-00016CEIegruS edomlaitnereffidVk1±edomnommocVk2±
edomlaitnereffidVk1,5.0±edomnommocVk2,1,5.0±
dluohsytilauqrewopsniaMlacipytafotahteb
latipsohrolaicremmoc.tnemnorivne
trohs,spidegatloVegatlovdnasnoitpurretniylppusrewopnosnoitairav11-4-00016CEIseniltupni
rof)tUnipid%59>(tU%5<elcyc5.0
5rof)tUnipid%06(tU%04selcyc
rof)tUnipid%03(tU%07selcyc52
rof)tUnipid%59>(tU%5<.ces5
rof)tUnipid%59>(tU%5<elcyc5.0
5rof)tUnipid%06(tU%04selcyc
rof)tUnipid%03(tU%07selcyc52
rof)tUnipid%59>(tU%5<.ces5
dluohsytiliauqrewopsniaMlacipytafotahteb
latipsohrolaicremmocforesuehtfI.tnemnorivne
seriuqer3KT51MMAgnirudnoitarepodeunitnoc
ti,snoitpurretnisniamrewoptahtdednemmocersiderewopeb3KT51MMA
elbitpurretninunamorf.yrettabaroylppusrewop
)zH06/05(ycneuqerfrewoPdleifcitengam8-4-00016CEI m/A3 A/N
citengamycneuqerf-rewoPsleveltaebdluohssdleiflacipytafocitsiretcarahc
lacipytaninoitacollatipsohrolaicremmoc
.tnemnorivne
FRdetcudnoC6-4-00016CEI
FRdetaidaR3-4-00016CEI
zHM08otzHK051smrV3
zHG5.2otzHM08m/V3
V3
m/V3
FRelibomdnaelbatroPtnempiuqesnoitacinummocotresolcondesuebdluohs3KT51MMAehtfotrapyna,selbacstignidulcni,metsys
dednemmocerehtnahtecnatsidnoitarapes
noitauqeehtmorfdetaluclacycneuqerfehtotelbacilppa
.rettimsnartehtfo
dednemmoceRecnatsiDnoitarapeS
p,71.1=dzHM008otzHM08p,71.1=d
otzHM008p,33.2=dzHG5.2
mumixamehtsiPerehwehtfognitarrewoptuptupo
)W(sttawnirettimsnartrettimsnartehtotgnidrocca
ehtsiddnarerutcafunamnoitarapesdednemmocer
.)m(sretemniecnatsid
FRdexifmorfshtgnertsdleiFdenimretedsa,srettimsnartetiscitengamortcelenayb
sselebdluohs,)a(yevrusnilevelecnailpmocehtnaht
.)b(egnarycneuqerfhcae
ehtniruccoyamycnerefretnIdekramtnempiuqefoytiniciv
:lobmysgniwllofehthtiw
.seilppaegnarycneuqerfrehgiheht,zHM008dnazHM08tA:1ETON
dnanoitprosbaybdetceffasinoitagaporpcitengamortcelE.snoitautisllaniylppatonyamsenilediugesehT:2ETON.elpoepdna,stcejbo,serutcurtsmorfnoitcelfer
.leveltsetehtfonoitacilppaotroirpgatlovsniam.c.aehtsitU:3ETON
elibomdnaldnasenohpelet)sseldroc/ralullec(oidarrofsnoitatsesabsahcus,srettimsnartdexifmorfshtgnertsdleiF)a(.ycaruccahtiwyllaciteroehtdetciderpebtonnoc,tsacdaorbVTdna,tsacdaorboidarMFdnaMA,oidarruetama,soidar
ebdluohsyevrusetiscitengamortcelena,srettimsnartFRdexifoteudtnemnorivnecitengamortceleehtssessaoTelbacilppaehtsdeecxedesusimetsys3KT51MMAehthcihwninoitacolehtnihtgnertsdleifderusaemehtfI.deredisnoc
lamronbafI.noitarepolamronyfirevotdevresboebdluohsmetsys3KT51MMAeht,evobalevelecnailpmocFR.tinu3KT51MMAehtgnitacolerrognitneircersahcus,yrassecenebyamserusaemlanoitidda,devresbosiecnamrofrep
.m/V3nahtsselebdluohsshtgnertsdleif,zHM08otzHk051egnarycneuqerfehtrevO)b(
FReliboMdnaelbatroPneewteBsecnatsiDnoitarapeSdednemmoceRmetsyS3KT51MMAehtdnatnemepiuqEsnoitacinummoC
hcihwnitnemnorivnecitengamortcelenaniesurofdednetnisimetsys3KT51MMAehTplehnacmetsys3KT51MMAehtforesuehT.dellortnocerasecnabrutsidFRdetaidar
neewtebecnatsidmuminimagniniatniamybecnerefretnicitengamortceletneverp3KT51MMAehtdna)srettimsnart(tnempiuqesnoitacinummocFRelibomdnaelbatrop
ehtforewoptuptuomumixamehtotgnidrocca,wolebdednemmocersametsys.tnempiuqesnoitacinummoc
mumixamdetaRfo)W(rewoptuptuo
rettimsnart
rettimsnartfoycneuqerfotgnidrocca)m(ecnatsidnoitarapeS
zHM08otzHk051p,71.1=d
zHM008otzHM08p,71.1=d
zHG5.2otzHM008p,33.2=d
10.0 21.0 21.0 32.0
1.0 73.0 73.0 47.0
1 71.1 71.1 33.2
01 07.3 07.3 73.7
001 07.11 07.11 03.32
dednemmocereht,evobadetsiltonrewoptuptuomumixamatadetarsrettimsnartroFehtotelbacilppanoitauqeehtgnisudetamitseebnac)m(sretemni)d(ecnatsidnoitarapesnirettimsnartehtfognitarrewoptuptuomumixamehtsiPerehw,rettimsnartehtfoycneuqerf
.rerutcafunamrettimsnartehtotgnidrocca)W(sttaw
egnarycneuqerfrehgihehtrofecnatsidnoitarapeseht,zHM008dnazHM08tA:1ETON.seilppa
sinoitagaporpcitengamortcelE.snoitautisllaniylppatonyamsenilediugesehT:2ETON.elpoepdna,stcejbo,serutcurtsmorfnoitcelferdnanoitprosbaybdetceffa
AMM15TK3 25
26 User’s GuideDimension Drawing (mm)
ConnectorsDC InputConnector Jack Power InputThe SCD-014-1-A (SHIUA CHYUAN) or equivalent.
Video Input24 pin DVI-I connector.DDWG or equivalent connector.
Touch Port9Pin D-subminiature connector.
niP tnemngissAlangiS niP tnemngissAlangiS niP tnemngissAlangiS
1 -2ataD.S.D.M.T 9 -1ataD.S.D.M.T 71 -0ataD.S.D.M.T
2 +2ataD.S.D.M.T 01 +1ataD.S.D.M.T 81 +0ataD.S.D.M.T
3 4/2ataD.S.D.M.TdleihS
11 3/1ataD.S.D.M.TdleihS
91 5/0ataD.S.D.M.TdleihS
4 -4ataD.S.D.M.T 21 -3ataD.S.D.M.T 02 -5ataD.S.D.M.T
5 +4ataD.S.D.M.T 31 +3ataD.S.D.M.T 22 +5ataD.S.D.M.T
6 kcolCCDD 41 rewoPV5+ 22 kcolC.S.D.M.TdleihS
7 ataDCDD 51 )V5+rof(dnuorG 32 +kcolC.S.D.M.T
8 cnySlacitreVgolanA 61 tceteDgulPtoH 42 -kcolC.S.D.M.T
1C deRgolanA 2C neerGgolanA 3C eulBgolanA
4C latnoziroHgolanAcnyS
5C DNGgolanAgolana(:nruteR
)B,G,R
noitpircseDniP
CDV21+1
DNG2
niP noitpircseD niP noitpircseS
1 DCD 6 RSD
2 DXR 7 STR
3 DXT 8 STC
4 RTD 9 CNIR
5 dnuorGcigoL
AMM15TK3 27
28 User’s GuideDescription of Warranty
Advan warrants that the goods the goods sold hereunder will be free of defects inmaterials and workmanship, and such goods will substantially conform to the specifi-cations furnished by Advan, and to any drawings or specifications furnished to Advanby the Buyer if approved by Advan. This warranty shall be effective only if Advanreceives notice of such defect or nonconformance during the period of the warranty.Advan sole and exclusive the Advan product(s) with refurbished units provide a creditto buyer in the amount of the purchase price.
Commencement and Duration of Warranty
The warranty period begins on the date of shipment from Advan. The goods soldhereunder are warranted for a period of 18 months from date of shipment unlessotherwise agreed to by Buyer and Advan. No extension of the warranty will be givenduring the time the goods are in Advan possession.
Place of Repair or ReplacementIn order to obtain service under this warranty, Buyer must notify Advan of the defectbefore expiration on the warranty period, and request a “Return Material AuthorizationNumber.” If the configuration has been modified in any manner, the product must bereturned to its original configuration before any warranty service will be perfomed byAdvan. No goods are to be returned to Advan without prior authorization. Buyer will beresponsible for packaging and shipping the defective goods to the Advan ServiceFacility with shipping charges prepaid.
Limitation of Warranty
Monitor:For 18 months after the date of purchase, ADVAN or its Authorized Service Centers, willrepair or replace if defective in material or workmanship. This Limited Warranty does notinclude cleaning, or damage caused by accident, neglect, misuse or improper installationor operation, any damage caused from service, maintenance, modifications or tamperingby anyone other than an ADVAN Authorized Service Representative, or by the use ofsupplies, consumable items and conditions beyond the control of ADVAN, such ascommon carrier provided equipment and/or facilities, operation of ADVAN product inexcess of the specifications or with the Serial Number or Rating label removed.
*Touch Screen:For one year after the date of purchase, ADVAN or its Authorized Service Centers, willrepair or replace if defective in material or workmanship. This Limited Warranty doesnot include cleaning, or damage caused by accident, neglect, misuse or improperinstallation or operation, any damage caused from service, maintenance, modifica-tions or tampering by anyone other than an ADVAN Authorized Service Representa-tive, or by the use of supplies, consumable items and conditions beyond the controlof ADVAN, such as common carrier provided equipment and/or facilities, operation ofADVAN product in excess of the specifications or with the Serial Number or Ratinglabel removed.
ADVAN DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUD-ING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITYOR FITNESS FOR PARTICULAR PURPOSE, EXCEPT TO THE EXTENT THAT ANYWARRANTIES IMPLIED BY LAW CANNOT BE VALIDLY WAIVED.
No oral or written information or advice given by ADVAN, its authorized service center,distributors, dealers, agents or employees, shall create another warranty or modifythis warranty. This warranty states ADVAN’s entire liability and your exclusiveremedy against ADVAN for any failure of the ADVAN’s product to operate properly.
Neither ADVAN nor anyone else involved in the development, production, or delivery ofthis product shall be liable for any indirect, incidental, special consequential, exem-plary, or punitive damages, including lost profits, arising from the use of or inability toconsequential or incidental damages, the above limitation may not apply to you.
This Limited Warranty gives you special legal rights and you may also have otherright, which vary from State to State.
InstallationAdvan makes no warranty with respect to any installation of Advan’s product(s)by Advan, any authorized dealer, or any other person.
Technical AssistanceFor technical assistance please call (510)490-1005 between 8:00 a.m. and 5:00 p.m.PST, Monday through Friday or email to [email protected] with a descriptionof your technical issues.
ServiceIf your Medical Monitor needs service, call Advan Customer Service at (510)490-1005between 7:00 a.m and 4:00 p.m PST, Monday through Friday or fax to (510)490-1151.You will need the unit’s serial number and a brief description of the problem and whereunit were purchased to receive a RMA number.
If a service is required please return the product for service using the originalshipping container with the RMA number included in package on the outsideof the box.
In order to protect ADVAN employees form potential health hazards, ADVANrequires that the RMA product be disinfected before returning to ADVAN forservice. Any product not cleaned prior to shipment will be returned to thecustomer.
In-transit damage is not covered by warranty. We suggest you always insure yourshipment. Advan will only pay for the return shipment by surface transportation. It isthe responsibility of the sender to prepay transportation charges.
Note: Returns will not be accepted without an assigned RMA number.
AMM15TK3 29
30 User’s GuideTounchscreen User's Manual (AMM15TK3-TE or AMM15TK3-TEW)
Quick Start1.Connect Power Cord and Video Cable of LCD Monitor.2.Connect Touchscreen DB9 male RS-232 cable.3.Turn the LCD display Power ON.4.Adjust the tilt of LCD Monitor.5.Adjust the Picture of LCD Monitor.6.Install driver software of Touchscreen (See "Driver software" for details).
7.Adjust the calibration of Touchscreen (See "Driver software" for details).
IntroductionThe ELO IntelliTouch Touchscreen system consists of a touchscreen and anelectronic touchscreen controller. The touchscreen may be a flat, spherical, orcylindrical and is installed over the face of the LCD. The touchscreen controllerinstalled inside of theLCD.
The IntelliTouch TouchscreenThe IntelliTouch surface wave touchscreen consists of a glass panel molded to theprecise shape of a display’s face. A scratch-resistant, hard-coated plastic cover sheet
may be clear for best image clarity or have an antiglare finish.
The IntelliTouch ControllerThe IntelliTouch controllers provide the drive signal for touchscreen, convert thereceived analogue signals into digital touch coordinates, and send these coordinatesto the computer.
Touchmonitor installation
Cable Connection1. Connect and test LCD as a video display only.2. Plug the DB9 male into the DB9 female connector labled "TOUCHSCREEN" on theback of the LCD Monitor.
Driver softwareELO provide driver programs for the DOS, Windows 3.1, Windows 95/98, WindowsNT, Windows 2000, Windows XP, OS/2, and Macintosh systems. Additional driversmay be available for other system. Contact ELO for details. Installing Driver softwarefor Windows / Windows NT1. Shutdown Windows or Windows NT and turn off your computer.2. Install touchscreen hardware as described in the "Quick start" or "Touchmonitorinstallation".3. Start your computer.4. Insert the Windows or Windows NT driver disk into diver A or B.5. Browse for "setup.exe" in the directory to which you extracted the driver files.6. Type "setup.exe" in the space provided and press Enter.7. The touchscreen setup wizard will appear. You will need to select serial port, typeof touchscreen controller, and language.8. Complete the setup program.9. Shutdown and restart windows NT.10. Click the start button, then click control panel.11. Double-click touchscreen control panel.12. Click the calibrate button and touch each of the three targets as they appear onthe screen.
Contacting ELOwww.elotouch.com
ELO Touchsystems INC.6500 Kaiser Drive Fremont,CA 94554 USA
AMM15TK3 31
ADVAN INT’L CORP47817 Fremont Blvd. Fremont, CA 94538Tel : 510-490-1005Fax : 510-490-1151Web Page : http://www.advancorp.com