Product evolution through technological revolution. Our new CoreCooling™ technology results in improved thermal performance and increased power density... it’s in the detail. To find out more visit stamford-avk.com

Enhanced thermal management

High efficiency air-flow

Adaptor foot option, enabling switching between S4 & S5

Optimised power density core

New core length, 450kVA

Flexible foot option, enabling switching between alternative brands

The New S4Fitted with CoreCooling™ technology

andwith

OUR DIFFERENCE?THE DETAIL.

YOU ASKED.WE LISTENED.

I want a smaller alternator for my generator set

Our new S0 and S1 is lighter and more

compact than previous alternators, without

compromising on genuine STAMFORD quality S0 & S1

The new

USA_PricingGuide2018_Cover_CMYK.indd 4 17/01/2018 10:46

Page 3: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

3

TABLE OF CONTENTSS Range Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inside Cover60 Hz, 1800 RPM, 4 Pole -S Series480 or 240 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5416 or 208 & 240 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6440 or 220 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7120 or 240 Volts, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8120 or 240 Volts, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 950 Hz, 1500 RPM, 4 Pole -S Series230 Volts Only, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10400-415 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11380/190 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 60Hz, 1800 RPM, 4 Pole480 or 240 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13440 or 220 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14416 or 208, 240/120 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15600 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16380 or 190 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17380 or 190 - 416 or 208 Volts, 3 Phase (Winding 14/13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18240/120 Volts, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19240/120 Volts, 1 Phase (Dedicated winding 06) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2050Hz, 1500 RPM, 4 Pole440 or 220 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21400-415 or 200-208 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22380 or 190 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23220/110 Volts, 1 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24220/110 Volts, 1 Phase (Dedicated winding 05) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 Pole, Industrial60Hz, 416, 440-480 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2650Hz, 380-440 Volts, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Marine 4 Pole: All Voltages, 50/60Hz, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 Pole: All Voltages, 60 Hz, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Marine Agency Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Medium Voltage4160 Volts/60 Hz and 3300 Volts/50 Hz, 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29High Voltage60Hz, 3 Phase, P80 Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3050Hz, 3 Phase, P80 Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Critical DimensionsCritical Dimensions - STAMFORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-34Critical Dimensions - P80 Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Generator OptionsHarsh Environment Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36UL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37AvK ProductAvK Product Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38AvK Alternators for Oil & Gas Drilling Rigs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 392 PoleSTAMFORD P0-P1 Series: All Voltages, 50/60Hz, 1 & 3 Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Specialty ProductRail Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Grid Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42STAMFORD PI634G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Marine Product Offerings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44-45Accessories / Service Parts / Testing / Technical InformationAccessory List Price / AVR Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47Accessory Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48-49Non- Linear Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Testing - Description and Charges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Recommended Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52-53Adaptors & Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54SAE Adaptor / Coupling Combinations and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Ratings Definitions / Available Windings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Altitude and Ambient deration / Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Motor Starting / PMG Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Current Transformers for Differential, Protection and Metering, 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Freight Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Cummins Generator Technologies Worldwide Reach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Americas Sales Contact Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Back Cover

Page 4: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

4

Page 5: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

S0L1-D1 AS540 12 151 8 .0 7 .7 7 .2 6 .9 6 .6 5 .8 $2,280 S0L1-H1 AS540 12 168 10 .6 10 .2 9 .6 9 .2 8 .7 7 .7 $2,375S0L1-L1 AS540 12 188 13 .2 12 .8 12 .0 11 .5 11 .0 9 .6 $2,485S0L1-P1 AS540 12 199 15 .8 15 .4 14 .4 13 .8 13 .1 11 .5 $2,590

AU

X. W

DG

ST

D

S0L2-F1 AS540 12 221 18 .5 17 .9 16 .8 16 .1 15 .3 13 .4 $2,950S0L2-G1 AS540 12 235 21 .1 20 .5 19 .2 18 .4 17 .4 15 .4 $3,080S0L2-M1 AS540 12 267 26 .4 25 .6 24 .0 23 .0 21 .8 19 .2 $3,345S0L2-P1 AS540 12 291 31 .7 30 .7 28 .8 27 .6 26 .2 23 .0 $3,640S1L2-J1 AS540 12 371 37 .0 36 .0 33 .6 32 .3 30 .6 26 .9 $3,860S1L2-K1 AS540 12 391 42 .2 41 .0 38 .4 36 .9 35 .0 30 .7 $4,380S1L2-N1 AS540 12 427 47 .5 46 .1 43 .2 41 .5 39 .3 34 .6 $4,440S1L2-R1 AS540 12 451 52 .8 51 .2 48 .0 46 .1 43 .7 38 .4 $4,500S1L2-Y1 AS540 12 531 66 .0 64 .0 60 .0 57 .6 54 .6 48 .0 $6,000

PM

G S

TD S4L1D-C MX341 12 1874 284 280 260 260 236 208 $13,550

S4L1D-D MX341 12 2072 344 332 312 312 284 248 $14,295S4L1D-E MX341 12 2258 392 380 364 364 328 288 $16,370S4L1D-F MX341 12 2557 460 444 416 416 384 332 $17,825S4L1D-G MX341 12 2623 500 480 448 448 408 356 $19,200

NEW PRODUCTS

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40 3. S4L1D SAE options available - Adaptor SAE - 1 & 0.5, Coupling SAE - 14 & 11.54. All units available in single bearing only

INDUSTRIAL Winding 311/711 - 12 wireClass H Insulation

Voltage: 480 or 240 Hz/RPM: 60/1800 Phase/PF: 3/0.8 Connection: WYE

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

5

Page 6: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

NEW PRODUCTS

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 403. S4L1D SAE options available - Adaptor SAE - 1 & 0.5, Coupling SAE - 14 & 11.54. All units available in single bearing only

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

S0L1-D1 AS540 12 151 7 .0 6 .8 6 .3 6 .1 5 .8 5 .1 $2,280 S0L1-H1 AS540 12 168 9 .3 9 .0 8 .4 8 .1 7 .7 6 .8 $2,375S0L1-L1 AS540 12 188 11 .6 11 .3 10 .6 10 .1 9 .6 8 .4 $2,485S0L1-P1 AS540 12 199 13 .9 13 .6 12 .7 12 .2 11 .5 10 .1 $2,590

AU

X. W

DG

ST

D

S0L2-F1 AS540 12 221 16 .3 15 .8 14 .8 14 .2 13 .5 11 .8 $2,950S0L2-G1 AS540 12 235 18 .6 18 .1 16 .9 16 .2 15 .4 13 .5 $3,080S0L2-M1 AS540 12 267 23 .2 22 .6 21 .1 20 .3 19 .2 16 .9 $3,345S0L2-P1 AS540 12 291 27 .9 27 .1 25 .3 24 .3 23 .1 20 .3 $3,640S1L2-J1 AS540 12 371 32 .5 31 .6 29 .6 28 .4 26 .9 23 .7 $3,860S1L2-K1 AS540 12 391 37 .2 36 .2 33 .8 32 .4 30 .8 27 .0 $4,380S1L2-N1 AS540 12 427 41 .8 40 .7 38 .0 36 .5 34 .6 30 .4 $4,440S1L2-R1 AS540 12 451 46 .5 45 .2 42 .2 40 .6 38 .4 33 .8 $4,500S1L2-Y1 AS540 12 531 58 .1 56 .5 52 .8 50 .7 48 .0 42 .2 $6,000

PM

G S

TD S4L1D-C MX341 12 1874 248 240 230 230 208 184 $13,550

S4L1D-D MX341 12 2072 300 292 275 275 252 220 $14,295S4L1D-E MX341 12 2258 348 336 320 320 292 252 $16,370S4L1D-F MX341 12 2557 400 388 364 364 336 292 $17,825S4L1D-G MX341 12 2623 452 428 400 400 364 320 $19,200

INDUSTRIALWinding 311/711 - 12 wire Class H Insulation

Voltage: 416 or 208 & 240 Hz/RPM: 60/1800 Phase/PF: 3/0.8 Connection: WYE & DELTA

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

6

Page 7: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

S0L1-D1 AS540 12 151 7 .4 7 .2 6 .7 6 .4 6 .1 5 .4 $2,280 S0L1-H1 AS540 12 168 9 .9 9 .6 9 .0 8 .6 8 .1 7 .2 $2,375S0L1-L1 AS540 12 188 12 .3 12 .0 11 .2 10 .7 10 .2 9 .0 $2,485S0L1-P1 AS540 12 199 14 .8 14 .4 13 .4 12 .9 12 .2 10 .7 $2,590

AU

X. W

DG

ST

D

S0L2-F1 AS540 12 221 17 .2 16 .8 15 .7 15 .0 14 .3 12 .5 $2,950S0L2-G1 AS540 12 235 19 .7 19 .2 17 .9 17 .2 16 .3 14 .3 $3,080S0L2-M1 AS540 12 267 24 .6 24 .0 22 .4 21 .5 20 .4 17 .9 $3,345S0L2-P1 AS540 12 291 29 .6 28 .7 26 .9 25 .8 24 .4 21 .5 $3,640S1L2-J1 AS540 12 371 34 .5 33 .5 31 .3 30 .1 28 .5 25 .1 $3,860S1L2-K1 AS540 12 391 39 .4 38 .3 35 .8 34 .4 32 .6 28 .7 $4,380S1L2-N1 AS540 12 427 44 .3 43 .1 40 .3 38 .7 36 .7 32 .2 $4,440S1L2-R1 AS540 12 451 48 .8 47 .5 44 .4 42 .6 40 .4 35 .5 $4,500S1L2-Y1 AS540 12 531 61 .0 59 .3 55 .4 53 .2 50 .5 44 .4 $6,000

PM

G S

TD S4L1D-C MX341 12 1874 276 264 248 248 224 196 $13,550

S4L1D-D MX341 12 2072 328 320 296 296 272 236 $14,295S4L1D-E MX341 12 2258 376 368 348 348 316 276 $16,370S4L1D-F MX341 12 2557 440 428 400 400 368 320 $17,825S4L1D-G MX341 12 2623 480 460 428 428 388 340 $19,200

NEW PRODUCTS

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 403. S4L1D SAE options available - Adaptor SAE - 1 & 0.5, Coupling SAE - 14 & 11.54. All units available in single bearing only

INDUSTRIAL Winding 311/711 - 12 wireClass H Insulation

Voltage: 440 or 220 Hz/RPM: 60/1800 Phase/PF: 3/0.8 Connection: WYE

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

7

Page 8: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

NEW PRODUCTS

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 403. All units available in single bearing only4. RTF = Refer to Factory

Model AVR Leads Wt. (Lbs)125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/Amb

List PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

S0L1-D1 AS540 12 151 3 .8 5 .4 RTF 3 .6 5 .2 RTF 3 .4 4 .9 RTF $2,280 S0L1-H1 AS540 12 168 5 .0 7 .2 RTF 4 .8 6 .9 RTF 4 .5 6 .6 RTF $2,375S0L1-L1 AS540 12 188 6 .2 9 .0 RTF 6 .0 8 .7 RTF 5 .7 8 .2 RTF $2,485S0L1-P1 AS540 12 199 7 .5 10 .9 RTF 7 .2 10 .4 RTF 6 .8 9 .9 RTF $2,590

AU

X. W

DG

ST

D

S0L2-F1 AS540 12 221 8 .7 12 .7 RTF 8 .4 12 .2 RTF 7 .9 11 .5 RTF $2,950S0L2-G1 AS540 12 235 10 .0 14 .5 RTF 9 .6 13 .9 RTF 9 .1 13 .2 RTF $3,080S0L2-M1 AS540 12 267 12 .5 18 .1 RTF 12 .0 17 .4 RTF 11 .4 16 .5 RTF $3,345S0L2-P1 AS540 12 291 15 .0 21 .7 RTF 14 .4 20 .8 RTF 13 .6 19 .8 RTF $3,640S1L2-J1 AS540 12 371 17 .5 25 .3 RTF 16 .8 24 .3 RTF 15 .9 23 .1 RTF $3,860S1L2-K1 AS540 12 391 20 .0 29 .0 RTF 19 .2 27 .8 RTF 18 .2 26 .3 RTF $4,380S1L2-N1 AS540 12 427 22 .5 32 .6 RTF 21 .6 31 .3 RTF 20 .4 29 .6 RTF $4,440S1L2-R1 AS540 12 451 25 .0 36 .2 RTF 24 .0 34 .7 RTF 22 .7 32 .9 RTF $4,500S1L2-Y1 AS540 12 531 31 .2 45 .2 RTF 30 .0 43 .4 RTF 28 .4 41 .2 RTF $6,000

INDUSTRIALWinding 311/711 - 12 wire Class H Insulation

Voltage: 120 or 240Hz/RPM: 60/1800 Phase/PF: 1/0.8-1.0 Connection: DOUBLE DELTA

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

8

Page 9: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 403. All units available in single bearing only4. RTF = Refer to Factory

Model AVR Leads Wt. (Lbs)

150/40 Rise/Amb 125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/AmbList

PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

S0L1-J1 AS540 4 77 7 .6 12 .2 81 .2 7 .2 11 .3 81 .5 6 .9 10 .3 RTF 6 .5 10 .2 82 $2,375 S0L1-S1 AS540 4 202 10 .2 13 .7 82 .6 9 .6 13 .0 82 .9 9 .2 12 .5 RTF 8 .6 11 .7 83 .4 $2,520

AU

X. W

DG

ST

D S0L2-G1 AS540 4 230 12 .3 16 .6 82 .3 11 .6 15 .6 82 .8 11 .1 15 .0 RTF 10 .5 14 .1 83 .4 $2,860

S0L2-M1 AS540 4 267 16 .4 22 .6 83 .4 15 .4 21 .0 83 .9 14 .8 20 .0 RTF 13 .9 19 .1 84 .5 $3,200

S0L2-U1 AS540 4 310 20 .5 29 .6 84 .4 19 .2 27 .5 84 .9 18 .4 25 .0 RTF 17 .4 25 .0 85 .5 $3,440S1L2-G1 AS540 4 343 22 .9 32 .3 85 .7 21 .6 30 .0 85 .9 20 .7 28 RTF 19 .5 27 .3 86 .4 $3,680S1L2-H1 AS540 4 353 24 .6 33 .2 84 .5 23 .2 31 .3 84 .8 22 .2 30 .0 RTF 21 .0 28 .3 85 .3 $3,740

S1L2-K1 AS540 4 383 29 .4 43 85 .7 27 .8 40 .0 86 .0 25 .8 36 .0 RTF 25 .1 36 .4 86 .4 $4,340

S1L2-N1 AS540 4 418 32 .6 45 .2 86 .6 30 .8 42 .0 87 .5 29 .6 40 .0 RTF 27 .9 38 .2 87 .2 $4,440

NEW PRODUCTS

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

9

INDUSTRIAL Winding 706/06 - 4 wireClass H Insulation

Voltage: 120 or 240 Hz/RPM: 60/1800 Phase/PF: 1/0.8-1.0 Connection: SERIES/PARALLEL

Page 10: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE

NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 403. All units available in single bearing only

Model AVR Leads Wt. (Lbs)

163/27 Rise/Amb 150/40 Rise/Amb 125/40 Rise/Amb 105/40 Rise/AmbList

PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

S0L1-J1 AS540 4 77 6 .6 8 .9 77 .8 6 .4 8 .6 78 .1 6 .0 8 .1 78 .6 5 .4 7 .4 79 .3 $2,375 S0L1-S1 AS540 4 202 8 .8 11 .9 80 .4 8 .6 11 .6 80 .6 8 .0 10 .8 90 .1 7 .3 9 .8 81 .7 $2,520

AU

X. W

DG

ST

D S0L2-K1 AS540 4 230 13 .2 17 .8 83 .7 12 .8 17 .3 83 .8 12 .0 16 .2 84 .2 11 .0 14 .7 84 .7 $2,860

S0L2-U1 AS540 4 310 17 .6 23 .8 85 .8 17 .0 23 .0 86 16 .0 21 .6 86 .2 14 .6 19 .7 86 .8 $3,440

S0L2-K1 AS540 4 383 22 .0 29 .7 85 .9 21 .4 28 .8 86 .1 20 .0 27 .0 86 .4 18 .2 24 .6 86 .9 $4,340

S1L2-R1 AS540 4 418 26 .4 35 .6 86 .2 25 .6 34 .6 86 .4 24 .0 32 .4 86 .8 21 .8 29 .5 87 .2 $4,440

NEW PRODUCTS

10

INDUSTRIALWinding 705/05 - 4 wireClass H Insulation

Voltage: 230 OnlyHz/RPM: 50/1500 Phase/PF: 1/0.8-1.0 Connection: SERIES/PARALLEL

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

Page 11: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

S0L1-D1 AS540 12 151 6 .6 6 .4 6 .0 RTF 5 .4 NA $2,280 S0L1-H1 AS540 12 168 8 .8 8 .6 8 .0 RTF 7 .3 NA $2,375S0L1-L1 AS540 12 188 11 .0 10 .6 10 .0 RTF 9 .1 NA $2,485S0L1-P1 AS540 12 199 13 .2 12 .8 12 .0 RTF 11 .0 NA $2,590

AU

X. W

DG

ST

D

S0L2-F1 AS540 12 221 15 .4 15 .0 14 .0 RTF 12 .7 NA $2,950S0L2-G1 AS540 12 235 17 .6 17 .0 16 .0 RTF 14 .6 NA $3,080S0L2-M1 AS540 12 267 22 .0 21 .4 20 .0 RTF 18 .2 NA $3,345S0L2-P1 AS540 12 291 26 .4 25 .6 24 .0 RTF 21 .8 NA $3,640S1L2-J1 AS540 12 371 30 .8 30 .0 28 .0 RTF 25 .5 NA $3,860S1L2-K1 AS540 12 391 35 .2 34 .1 32 .0 RTF 29 .1 NA $4,380S1L2-N1 AS540 12 427 39 .6 38 .4 36 .0 RTF 32 .8 NA $4,440S1L2-R1 AS540 12 451 44 .0 42 .6 40 .0 RTF 36 .4 NA $4,500S1L2-Y1 AS540 12 531 55 .0 53 .3 50 .0 RTF 45 .5 NA $6,000

PM

G S

TD S4L1D-C MX341 12 1874 228 224 208 208 188 164 $13,550

S4L1D-D MX341 12 2072 272 264 248 248 228 196 $14,295S4L1D-E MX341 12 2258 332* 308 288 288 260 228 $16,370S4L1D-F MX341 12 2557 372** 356 332 332 304 264 $17,825S4L1D-G MX341 12 2623 400 384 360 360 328 288 $19,200

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard2. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40 3. S4L1D SAE options available - Adaptor SAE - 1 & 0.5, Coupling SAE - 14 & 11.54. All units available in single bearing only 5. RTF = Refer to Factory 6. *320KW @415V 7. **364KW @ 415V

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

11

NEW PRODUCTSINDUSTRIALWinding 311 - 12 wireClass H Insulation

Voltage: 400 - 415Hz/RPM: 50/1500 Phase/PF: 3/0.8 Connection: WYE

Page 12: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

PM

G S

TD S4L1D-C MX341 12 1874 220 216 200 200 184 160 $13,550

S4L1D-D MX341 12 2072 264 256 240 240 224 192 $14,295S4L1D-E MX341 12 2258 304 296 280 280 256 220 $16,370

S4L1D-F MX341 12 2557 340 332 320 320 296 256 $17,825

S4L1D-G MX341 12 2623 380 364 344 344 312 276 $19,200

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. Adaptor SAE - 1 & 0.52. Coupling SAE - 14 & 11.5 3. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 404. All units available in single bearing only

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

12

NEW PRODUCTSINDUSTRIALWinding 311 - 12 wireClass H Insulation

Voltage: 380/190Hz/RPM: 50/1500Phase/PF: 3/0.8 Connection: WYE

Page 13: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

13

INDUSTRIAL Voltage: 480 or 240Winding 311 - 12 wire Hz/RPM: 60/1800Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 8 .2 8 .1 7 .5 7 .5 6 .8 6 $2,720PI044E AS480 12 172 11 10 .8 10 10 9 .1 8 $3,000PI044F AS480 12 192 13 .8 13 .5 12 .5 12 .5 11 .4 10 $3,175PI044G AS480 12 207 16 .5 16 .2 15 15 13 .7 12 $3,280PI044H AS480 12 231 19 .3 18 .9 17 .5 17 .5 16 14 $3,415PI144D AS480 12 261 22 21 .5 20 20 18 .2 16 $3,540PI144E AS480 12 293 27 .5 26 .9 25 25 22 .7 20 $3,850PI144F AS480 12 312 30 .2 29 .6 27 .5 27 .5 25 22 $4,100PI144G AS480 12 348 33 32 .2 30 30 27 .5 24 $4,490PI144H AS480 12 376 38 .5 37 .5 35 35 32 28 $4,575PI144J AS480 12 401 45 44 40 40 36 .5 32 $4,730PI144K AS480 12 421 48 46 .5 44 44 38 .4 33 .7 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 48 46 .5 44 44 38 .4 33 .6 $5,340UCI224D SX460 12 583 57 55 52 52 46 .4 40 $5,800UCI224E SX460 12 636 64 63 60 60 54 .5 48 $6,195UCI224F SX460 12 714 82 80 75 75 66 57 .4 $6,785UCI224G SX460 12 798 91 88 83 83 76 66 $7,175UCI274C SX460 12 866 110 106 100 100 90 78 $8,130UCI274D SX460 12 923 127 125 117 117 105 88 $8,425UCI274E SX460 12 1050 155 150 143 143 128 110 $9,380UCI274F SX460 12 1148 175 170 165 165 150 128 $10,330UCI274G SX460 12 1259 202 .6 200 185 .1 185 169 .8 140 $10,840UCI274H SX460 12 1352 224 220 204 204 188 163 $11,680UCDI274J SX460 12 1588 260 255 240 240 220 194 $12,255UCDI274K SX460 12 1665 275 265 250 250 230 .4 200 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 276 268 252 252 232 200 $13,550S4L1S-D4 MX341 12 2123 332 320 300 300 276 240 $14,295S4L1S-E4 MX341 12 2307 380 368 352 352 320 280 $16,370S4L1S-F4 MX341 12 2584 440 428 400 400 372 320 $17,825HCI534C MX341 12 2965 515 500 475 475 430 .4 376 $20,390HCI534D MX341 12 3254 555 540 515 515 470 .4 412 $21,185HCI534E MX341 12 3523 655 640 600 600 540 475 $24,895HCI534F MX341 12 3840 725 700 660 660 600 528 $27,195HCI634G MX321 12 4327 870 837 800 800 730 .4 632 $33,080HCI634H MX321 12 4658 975 950 900 884 820 720 $36,385HCI634J MX321 12 5000 1120 1080 1040 988 950 828 $38,730HCI634K MX321 12 5602 1260 1220 1150 1080 1050 .4 900 $41,095HCI634G MX321 6 4327 870 837 800 800 730 .4 632 $33,080HCI634H MX321 6 4658 975 950 900 900 820 720 $36,385HCI634J MX321 6 5000 1120 1080 1040 1040 950 828 $38,730HCI634K MX321 6 5602 1260 1220 1150 1150 1050 900 $41,095PI634G MX321 6 5860 1264 1250 1210 RTF 1109 — $43,575 PI734A MX321 6 6093 1304 1268 1220 1217 1132 1048 $46,515PI734B MX321 6 6093 1448 1408 1352 1352 1260 1164 $47,460PI734C MX321 6 6692 1620 1576 1512 1512 1408 1300 $55,200PI734D* MX321 6 7325 1728 1680 1612 1612 1500 1388 $59,840PI734E MX321 6 7408 1972 1916 1840 1840 1712 1584 $66,710PI734F MX321 6 8477 2228 2164 2080 2080 1936 1792 $73,195PI734G MX321 6 8949 2356 2288 2200 2200 2048 1892 $81,360

P80 LVSI804R DM110 6 12220 2640 2560 2400 2348 2200 1920 $155,990 P80 LVSI804S DM110 6 12327 2948 2868 2680 2600 2460 2144 $173,210 P80 LVSI804T DM110 6 13099 3220 3132 2928 2840 2688 2272 $198,115 P80 LVSI804W DM110 6 17457 — 3544 3314 3244 3097 2691 $252,650 P80 LVSI804X DM110 6 17587 — 3816 3571 3428 3338 2900 $288,505

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES: 1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 480 Volts only and not reconnectable to Delta.4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only. 6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

Page 14: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

14

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 7 .8 7 .6 7 7 6 .4 5 .7 $2,720PI044E AS480 12 172 10 .3 10 .2 9 .4 9 .4 8 .6 7 .5 $3,000PI044F AS480 12 192 13 12 .7 11 .8 11 .8 10 .7 9 .4 $3,175PI044G AS480 12 207 15 .5 15 .2 14 .1 14 .1 12 .9 11 .3 $3,280PI044H AS480 12 231 18 .1 17 .8 16 .5 16 .5 15 13 .2 $3,415PI144D AS480 12 261 20 .7 20 .2 18 .8 18 .8 17 .1 15 $3,540PI144E AS480 12 293 25 .8 25 .3 23 .5 23 .5 21 .4 18 .8 $3,850PI144F AS480 12 312 28 .4 27 .8 25 .8 25 .8 23 .5 20 .7 $4,100PI144G AS480 12 348 31 30 .3 28 .2 28 .2 25 .8 22 .6 $4,490PI144H AS480 12 376 36 .2 35 .3 32 .9 32 .9 30 .1 26 .3 $4,575PI144J AS480 12 401 42 .3 41 .4 37 .6 37 .6 34 .3 30 .1 $4,730PI144K AS480 12 421 45 44 42 42 37 32 .5 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 45 44 42 42 37 32 $5,340UCI224D SX460 12 583 53 52 50 50 44 38 $5,800UCI224E SX460 12 636 60 59 56 56 52 44 $6,195UCI224F SX460 12 714 76 74 70 70 62 .5 54 .4 $6,785UCI224G SX460 12 798 85 82 78 78 72 62 $7,175UCI274C SX460 12 866 102 100 94 94 85 74 $8,130UCI274D SX460 12 923 120 116 110 110 100 87 $8,425UCI274E SX460 12 1050 145 140 134 134 115 98 $9,380UCI274F SX460 12 1148 165 160 152 152 138 120 $10,330UCI274G SX460 12 1259 187 .2 183 174 .8 175 159 .2 138 $10,840UCI274H SX460 12 1352 212 207 196 196 180 156 $11,680UCDI274J SX460 12 1588 244 .8 240 224 .8 225 211 .2 185 $12,255UCDI274K SX460 12 1665 256 250 239 .2 239 220 193 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 264 256 240 240 220 192 $13,550S4L1S-D4 MX341 12 2123 316 308 288 288 268 232 $14,295S4L1S-E4 MX341 12 2307 364 356 336 336 308 268 $16,370S4L1S-F4 MX341 12 2584 424 412 384 384 356 308 $17,825HCI534C MX341 12 2965 480 465 440 440 430 .4 352 $20,390HCI534D MX341 12 3254 515 500 475 475 430 376 $21,185HCI534E MX341 12 3523 615 600 570 570 520 456 $24,895HCI534F MX341 12 3840 675 655 620 620 575 .2 506 $27,195HCI634G MX321 12 4327 800 775 740 740 675 .2 588 $33,080HCI634H MX321 12 4658 930 900 850 832 770 .4 680 $36,385HCI634J MX321 12 5000 1040 1000 960 912 880 760 $38,730HCI634K MX321 12 5602 1170 1130 1070 1008 990 .4 860 $41,095HCI634G MX321 6 4327 800 775 740 740 675 .2 588 $33,080HCI634H MX321 6 4658 930 900 850 850 770 .4 680 $36,385HCI634J MX321 6 5000 1040 1000 960 960 880 760 $38,730HCI634K MX321 6 5602 1170 1130 1070 1070 990 .4 860 $41,095PI634G MX321 6 5860 1158 1146 1109 RTF 1016 — $43,575 PI734A MX321 6 6093 1284 1248 1200 1170 1116 1008 $46,515PI734B MX321 6 6093 1392 1352 1300 1300 1208 1120 $47,460PI734C MX321 6 6692 1556 1512 1452 1452 1352 1252 $55,200PI734D* MX321 6 7325 1656 1612 1548 1548 1440 1332 $59,840PI734E MX321 6 7408 1892 1840 1768 1768 1644 1520 $66,710PI734F MX321 6 8477 2140 2080 2000 2000 1860 1720 $73,195PI734G MX321 6 8949 2192 2108 2028 2028 1888 1816 $81,360P80 LVSI804R DM110 6 12220 2420 2352 2200 2152 2016 1760 $155,990 P80 LVSI804S DM110 6 12327 2704 2628 2456 2384 2256 1964 $173,210 P80 LVSI804T DM110 6 13099 2952 2872 2684 2604 2464 2176 $198,115 P80 LVSI804W DM110 6 17457 — 3248 3040 2976 2840 2468 $252,650 P80 LVSI804X DM110 6 17587 — 3496 3272 3140 3056 2640 $288,505

INDUSTRIAL Voltage: 440 or 220Winding 311 - 12 wire Hz/RPM: 60/1800Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 440 Volts only and not

reconnectable to Delta.

4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature rise

at 120 or below, and ambient up to 40.

Page 15: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

15

INDUSTRIAL Voltage: 416 or 208 and 240/120Winding 311 - 12 wire Hz/RPM: 60/1800Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE & DELTA

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 7 .3 7 .1 6 .6 6 .6 6 5 .3 $2,720PI044E AS480 12 172 9 .7 9 .5 8 .8 8 .8 8 7 $3,000PI044F AS480 12 192 12 .1 11 .9 11 11 10 8 .8 $3,175PI044G AS480 12 207 14 .6 14 .2 13 .2 13 .2 12 .1 10 .6 $3,280PI044H AS480 12 231 17 16 .6 15 .4 15 .4 14 .1 12 .3 $3,415PI144D AS480 12 261 19 .4 19 17 .6 17 .6 16 14 .1 $3,540PI144E AS480 12 293 24 .2 23 .7 22 22 20 17 .6 $3,850PI144F AS480 12 312 26 .6 26 .1 24 .2 24 .2 22 19 .4 $4,100PI144G AS480 12 348 29 28 .4 26 .4 26 .4 24 .2 21 .1 $4,490PI144H AS480 12 376 33 .9 33 30 .8 30 .8 28 .2 24 .6 $4,575PI144J AS480 12 401 39 .6 38 .7 35 .2 35 .2 32 .2 28 .2 $4,730PI144K AS480 12 421 44 42 .5 40 40 36 31 .6 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 44 42 .5 40 40 36 31 $5,340UCI224D SX460 12 583 52 50 48 48 42 36 .4 $5,800UCI224E SX460 12 636 58 56 54 54 50 42 .5 $6,195UCI224F SX460 12 714 73 .5 71 67 67 60 52 .2 $6,785UCI224G SX460 12 798 81 78 .5 75 75 70 60 $7,175UCI274C SX460 12 866 96 93 90 90 78 67 .5 $8,130UCI274D SX460 12 923 114 110 105 105 96 80 $8,425UCI274E SX460 12 1050 140 136 128 128 112 96 $9,380UCI274F SX460 12 1148 154 150 145 145 130 112 $10,330UCI274G SX460 12 1259 174 .8 170 164 165 154 .2 133 $10,840UCI274H SX460 12 1352 205 200 190 190 175 150 $11,680UCDI274J SX460 12 1588 235 .2 230 .4 215 .2 215 200 176 $12,255UCDI274K SX460 12 1665 249 .6 243 .2 232 .8 233 213 .6 187 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 248 240 230 228 208 184 $13,550S4L1S-D4 MX341 12 2123 300 292 275 272 252 220 $14,295S4L1S-E4 MX341 12 2307 348 336 320 320 292 244 $16,370S4L1S-F4 MX341 12 2584 400 388 364 364 336 282 $17,825HCI534C MX341 12 2965 455 440 420 420 384 .5 336 $20,390HCI534D MX341 12 3254 485 470 460 460 415 .2 360 $21,185HCI534E MX341 12 3523 590 575 545 545 500 440 $24,895HCI534F MX341 12 3840 645 625 590 590 550 .4 484 $27,195HCI634G MX321 12 4327 760 730 700 700 650 .4 568 $33,080HCI634H MX321 12 4658 900 870 820 804 730 .4 632 $36,385HCI634J MX321 12 5000 1000 965 920 876 850 .4 740 $38,730HCI634K MX321 12 5602 1120 1080 1020 960 950 .4 824 $41,095HCI634G MX321 6 4327 760 730 700 700 650 .4 568 $33,080HCI634H MX321 6 4658 900 870 820 820 730 .4 632 $36,385HCI634J MX321 6 5000 1000 965 920 920 850 .4 740 $38,730HCI634K MX321 6 5602 1120 1080 1020 1020 950 .4 824 $41,095PI634G MX321 6 5860 1095 1083 1048 RTF 960 — $43,575 PI734A MX321 6 6093 1174 1140 1100 1096 1020 943 $46,515PI734B MX321 6 6093 1304 1272 1220 1220 1132 1048 $47,460PI734C MX321 6 6692 1456 1416 1364 1364 1272 1172 $55,200PI734D* MX321 6 7325 1552 1512 1452 1452 1352 1252 $59,840PI734E MX321 6 7408 1772 1724 1656 1656 1548 1424 $66,710PI734F MX321 6 8477 2004 1948 1876 1872 1752 1612 $73,195PI734G MX321 6 8949 2072 2012 1936 1936 1804 1704 $81,360P80 LVSI804R DM110 6 12220 2288 2224 2080 2036 1908 1664 $155,990 P80 LVSI804S DM110 6 12327 2556 2484 2320 2252 2132 1860 $173,210 P80 LVSI804T DM110 6 13099 2792 2712 2536 2460 2328 2056 $198,115 P80 LVSI804W DM110 6 17457 — 3072 2872 2812 2680 2332 $252,650 P80 LVSI804X DM110 6 17587 — 3304 3096 2968 2892 2512 $288,505

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 416 Volts only and not

reconnectable to Delta.

4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature

rise at 120 or below, and ambient up to 40.

Page 16: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

16

INDUSTRIAL Voltage: 600Winding 17 (12 Wire) Hz/RPM: 60/1800Winding 07 (6 Wire) Phase/PF: 3/0.8Class H Insulation Connection: WYE

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 8 .2 7 .9 7 .5 7 .5 6 .8 6 $2,720PI044E AS480 12 172 10 .9 10 .5 10 10 9 8 $3,000PI044F AS480 12 192 13 .6 13 .1 12 .5 12 .5 11 .2 10 $3,175PI044G AS480 12 207 16 .4 15 .8 15 15 13 .5 12 $3,280PI044H AS480 12 231 19 .1 18 .4 17 .5 17 .5 15 .8 14 $3,415PI144D AS480 12 261 21 .8 21 20 20 18 16 $3,540PI144E AS480 12 293 27 .3 26 .3 25 25 22 .6 20 $3,850PI144F AS480 12 312 30 28 .9 27 .5 27 .5 24 .8 22 $4,100PI144G AS480 12 348 32 .7 31 .5 30 30 27 24 $4,490PI144H AS480 12 376 38 .2 36 .8 35 35 31 .5 28 $4,575PI144J AS480 12 401 43 .6 42 40 40 36 32 $4,730PI144K AS480 12 421 48 46 .2 44 44 39 .6 35 .2 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 48 46 .5 44 44 38 .4 33 .6 $5,340UCI224D SX460 12 583 57 55 52 52 46 .4 40 $5,800UCI224E SX460 12 636 64 63 60 60 54 .4 48 $6,195UCI224F SX460 12 714 82 79 75 .2 75 66 57 .4 $6,785UCI224G SX460 12 798 91 88 83 83 76 66 $7,175UCI274C SX460 12 866 105 .6 101 .6 96 96 88 76 $8,130UCI274D SX460 12 923 127 124 117 117 105 88 $8,425UCI274E SX460 12 1050 155 150 143 143 128 110 $9,380UCI274F SX460 12 1148 175 170 165 165 150 128 $10,330UCI274G SX460 12 1259 197 192 180 180 165 140 $10,840UCI274H SX460 12 1352 224 220 204 204 188 163 .2 $11,680UCDI274J SX460 12 1588 267 .2 262 .4 244 244 224 .8 195 $12,255UCDI274K — — — — — — — — — —

PM

G S

TD

S4L1S-C4 MX341 12 1952 276 268 252 252 232 200 $13,550S4L1S-D4 MX341 12 2123 332 320 300 300 276 240 $14,295S4L1S-E4 MX341 12 2307 380 368 352 352 320 280 $16,370S4L1S-F4 MX341 12 2584 440 428 400 400 372 320 $17,825HCI534C MX341 12 2965 492 476 450 450 412 358 $20,390HCI534D MX341 12 3254 555 540 515 515 470 .4 412 $21,185HCI534E MX341 12 3523 632 616 580 580 526 .4 456 $24,895HCI534F MX341 12 3840 725 700 660 660 600 528 $27,195HCI634G MX321 6 4327 870 837 800 800 730 .4 632 $33,080HCI634H MX321 6 4658 930 900 850 850 770 .4 680 $36,385HCI634J MX321 6 5000 1120 1080 1040 1040 950 .4 828 $38,730HCI634K MX321 6 5602 1260 1220 1150 1150 1050 .4 900 $41,095PI634G MX321 6 5860 — — — — — — $43,575 PI734A MX321 6 6093 1304 1268 1200 1200 1132 1048 $46,515PI734B MX321 6 6093 1448 1408 1352 1352 1260 1164 $47,460PI734C MX321 6 6692 1620 1576 1512 1512 1408 1300 $55,200PI734D* MX321 6 7325 1728 1680 1612 1612 1500 1388 $59,840PI734E MX321 6 7408 1972 1916 1840 1840 1712 1584 $66,710PI734F MX321 6 8477 2228 2164 2080 2080 1936 1792 $73,195PI734G MX321 6 8949 2356 2288 2200 2200 2048 1892 $81,360P80 LVSI804R — — — — — — — — — —P80 LVSI804S DM110 6 12327 2948 2868 2680 2600 2460 2144 $173,210 P80 LVSI804T — — — — — — — — — —P80 LVSI804W DM110 6 17457 — 3544 3314 3244 3097 2691 $252,650 P80 LVSI804X DM110 6 17587 — 3816 3571 — 3338 2900 $288,505

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 600 Volts only and not reconnectable to Delta.4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only. 6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

Page 17: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

17

INDUSTRIAL Voltage: 380 or 190Winding 311 - 12 wire Hz/RPM: 60/1800Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET.3. Six wire machines are 380 Volts only and not

reconnectable to Delta.

4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only.

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 6 .8 6 .6 6 .2 6 .2 5 .6 5 $2,720PI044E AS480 12 172 9 8 .9 8 .2 8 .2 7 .4 6 .6 $3,000PI044F AS480 12 192 11 .2 11 10 .2 10 .2 9 .4 8 .2 $3,175PI044G AS480 12 207 13 .5 13 .3 12 .3 12 .3 11 .2 9 .8 $3,280PI044H AS480 12 231 15 .7 15 .5 14 .3 14 .3 13 .1 11 .5 $3,415PI144D AS480 12 261 18 17 .6 16 .4 16 .4 15 13 .1 $3,540PI144E AS480 12 293 22 .5 22 .1 20 .5 20 .5 18 .6 16 .4 $3,850PI144F AS480 12 312 24 .8 24 .2 22 .6 22 .6 20 .5 18 .1 $4,100PI144G AS480 12 348 27 26 .5 24 .6 24 .6 22 .6 19 .7 $4,490PI144H AS480 12 376 31 .6 30 .7 28 .7 28 .7 26 .2 23 $4,575PI144J AS480 12 401 36 .8 36 .1 32 .8 32 .8 29 .9 26 .2 $4,730PI144K AS480 12 421 39 .3 38 .1 36 .1 36 .1 31 .5 27 .6 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 40 38 .8 36 .4 36 .4 32 .8 28 $5,340UCI224D SX460 12 583 47 .5 45 .6 43 .8 43 .8 38 .4 33 .2 $5,800UCI224E SX460 12 636 52 .8 51 49 .2 49 .2 45 .6 38 .6 $6,195UCI224F SX460 12 714 67 64 .5 61 61 54 .6 47 .5 $6,785UCI224G SX460 12 798 73 .8 71 .5 68 .3 68 .3 63 .5 54 .6 $7,175UCI274C SX460 12 866 87 85 82 82 71 61 .5 $8,130UCI274D SX460 12 923 104 100 96 96 88 72 $8,425UCI274E SX460 12 1050 128 124 112 112 102 88 $9,380UCI274F SX460 12 1148 140 137 132 132 118 102 $10,330UCI274G SX460 12 1259 159 154 149 149 138 117 $10,840UCI274H SX460 12 1352 187 182 170 170 160 135 $11,680UCDI274J SX460 12 1588 215 210 200 200 180 155 $12,255UCDI274K SX460 12 1665 220 215 206 206 188 164 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 228 220 208 208 192 168 $13,550S4L1S-D4 MX341 12 2123 272 264 248 248 232 200 $14,295S4L1S-E4 MX341 12 2307 304 296 276 276 256 220 $16,370S4L1S-F4 MX341 12 2584 356 344 324 324 294 256 $17,825HCI534C MX341 12 2965 415 400 384 384 350 304 $20,390HCI534D MX341 12 3254 440 428 420 420 376 328 $21,185HCI534E MX341 12 3523 538 525 498 498 456 400 $24,895HCI534F MX341 12 3840 590 570 538 538 500 440 $27,195HCI634G MX321 12 4327 690 665 640 640 580 520 $33,080HCI634H MX321 12 4658 820 795 750 750 690 575 $36,385HCI634J MX321 12 5000 910 880 840 840 775 675 $38,730HCI634K MX321 12 5602 1020 985 930 930 865 750 $41,095HCI634G MX321 6 4327 690 665 640 640 580 520 $33,080HCI634H MX321 6 4658 820 795 750 750 690 575 $36,385HCI634J MX321 6 5000 910 880 840 840 775 675 $38,730HCI634K MX321 6 5602 1020 985 930 930 865 750 $41,095PI634G MX321 6 5860 — — — — — — $43,575 PI734A MX321 6 6093 1033 1004 965 965 896 832 $46,515PI734B MX321 6 6093 1148 1116 1072 1072 996 924 $47,460PI734C MX321 6 6692 1284 1252 1200 1200 1120 1032 $55,200PI734D* MX321 6 7325 1368 1328 1276 1276 1188 1100 $59,840PI734E MX321 6 7408 1560 1516 1460 1460 1356 1256 $66,710PI734F MX321 6 8477 1764 1716 1648 1648 1532 1416 $73,195PI734G MX321 6 8949 1864 1812 1744 1744 1620 1500 $81,360P80 LVSI804R — — — — — — — — — —P80 LVSI804S — — — — — — — — — —P80 LVSI804T — — — — — — — — — —P80 LVSI804W — — — — — — — — — —P80 LVSI804X — — — — — — — — — —

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY

Page 18: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

18

INDUSTRIAL Voltage: 380 or 190 - 416 or 208 Special Wdg. 14 - 12 Wire Hz/RPM: 60/1800 Special Wdg. 13 - 6 Wire Phase/PF: 3/0.8 Class H Insulation Connection: WYE

Model AVR Leads Wt. (Lbs)kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40 80/40

EB

S O

PT

ION

AL

PI044D AS480 12 161 8 .2 7 .9 7 .5 7 .5 6 .8 6 $2,720PI044E AS480 12 172 10 .9 10 .5 10 10 9 8 $3,000PI044F AS480 12 192 13 .1 12 .6 12 12 10 .8 9 .6 $3,175PI044G AS480 12 207 16 .4 15 .8 15 15 13 .5 12 $3,280PI044H AS480 12 231 18 .3 17 .7 16 .8 16 .8 15 .1 13 .4 $3,415PI144D AS480 12 261 21 .8 21 20 20 18 16 $3,540PI144E AS480 12 293 26 .2 25 .2 24 24 21 .6 19 .2 $3,850PI144F AS480 12 312 28 .8 27 .8 26 .4 26 .4 23 .8 21 .1 $4,100PI144G AS480 12 348 32 .7 31 .5 30 30 27 24 $4,490PI144H AS480 12 376 38 .2 36 .8 35 35 31 .5 28 $4,575PI144J AS480 12 401 41 .4 39 .9 38 38 34 .2 30 .4 $4,730PI144K AS480 12 421 48 46 .2 44 44 39 .6 35 .2 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 48 46 .5 44 44 38 .4 33 .6 $5,340 UCI224D SX460 12 583 53 52 50 50 44 .8 38 .8 $5,800 UCI224E SX460 12 636 60 59 56 56 52 44 $6,195 UCI224F SX460 12 714 73 .6 71 .5 68 68 60 52 $6,785 UCI224G SX460 12 798 85 82 80 80 75 65 $7,175 UCI274C SX460 12 866 105 .6 101 .6 96 96 88 76 $8,130 UCI274D SX460 12 923 114 110 105 105 96 80 $8,425 UCI274E SX460 12 1050 140 136 128 128 112 96 $9,380 UCI274F SX460 12 1148 152 148 .8 144 144 128 110 $10,330 UCI274G SX460 12 1259 170 166 160 160 150 130 $10,840 UCI274H SX460 12 1352 205 200 190 190 175 150 $11,680 UCDI274J SX460 12 1588 260 255 240 240 220 190 $12,255 UCDI274K — — — — — — — — — —

PM

G S

TD

S4L1S-C4 MX341 12 1952 264 256 240 240 220 192 $13,550 S4L1S-D4 MX341 12 2123 308 300 280 280 252 216 $14,295 S4L1S-E4 — — — — — — — — — —S4L1S-F4 MX341 6 2584 440 428 400 400 372 320 $17,825 HCI534C MX341 12 2965 432 416 400 400 368 320 $20,390 HCI534D MX341 12 3254 538 524 500 500 450 .4 396 $21,185 HCI534E MX341 12 3523 584 568 540 540 496 428 $24,895 HCI534F MX341 12 3840 725 700 660 660 600 528 $27,195 HCI634G MX321 6 4327 760 730 700 700 650 568 $33,080 HCI634H MX321 6 4658 864 840 800 800 728 630 $36,385 HCI634J MX321 6 5000 1080 1040 1000 1000 920 800 $38,730 HCI634K MX321 6 5602 1200 1164 1100 1100 1008 872 $41,095 PI634G MX321 6 5860 — — — — — — $43,575 PI734A MX321 6 6093 1204 1168 1124 1124 1048 968 $46,515 PI734B MX321 6 6093 1336 1300 1248 1248 1164 1076 $47,460 PI734C MX321 6 6692 1516 1476 1416 1416 1320 1220 $55,200 PI734D* MX321 6 7325 1640 1596 1532 1532 1428 1320 $59,840 PI734E — — — — — — — — — —PI734F MX321 6 8477 2144 2084 2004 2004 1864 1724 $73,195 PI734G — — — — — — — — — —P80 LVSI804R DM110 6 12220 — 2400 2260 2170 2072 1655 $155,990 P80 LVSI804S DM110 6 12327 — 2776 2600 2548 2380 2104 $173,210 P80 LVSI804T DM110 6 13099 — 2904 2720 2608 2504 2200 $198,115 P80 LVSI804W DM110 6 17457 — 3200 3000 — 2760 2424 $252,650 P80 LVSI804X — — — — — — — — — —

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. List price adder: PMG/MX341 - $880

PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET.3. Six wire machines are 380-416 Volts only and not reconnectable to Delta.4. Weights are single bearing, packing excluded.5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.7. For LVS1804 models only 380V is applicable.

Page 19: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

19

INDUSTRIAL Voltage: 240/120Winding 311 - 12 wire Hz/RPM: 60/1800Class H Insulation Phase/PF: 1 / 0.8-1.0 Connection: Double Delta

Model AVR Leads Wt. (Lbs)

125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/AmbList

PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

EB

S O

PT

ION

AL

PI044D AS480 12 161 4 6 74 .6 4 — 74 .6 3 .6 5 .4 75 $2,720

PI044E AS480 12 172 5 .3 7 .9 76 .8 5 .3 — 76 .8 4 .8 7 .2 77 .2 $3,000

PI044F AS480 12 192 6 .6 10 78 .3 6 .6 — 78 .3 6 9 78 .8 $3,175

PI044G AS480 12 207 7 .9 11 .9 78 .5 7 .9 — 78 .5 7 .2 10 .8 78 .9 $3,280

PI044H AS480 12 231 9 .3 13 .9 79 .8 9 .3 — 79 .8 8 .5 12 .7 80 .3 $3,415

PI144D AS480 12 261 10 .6 14 .3 82 .3 10 .6 — 82 .3 9 .6 13 82 .6 $3,540

PI144E AS480 12 293 13 .2 17 .8 82 .1 13 .2 — 82 .1 12 16 .2 82 .4 $3,850

PI144F AS480 12 312 14 .6 19 .7 83 .4 14 .6 — 83 .4 13 .2 17 .8 83 .8 $4,100

PI144G AS480 12 348 15 .8 21 .4 83 .6 15 .8 — 83 .6 14 .6 19 .7 84 $4,490

PI144H AS480 12 376 18 .5 24 .9 84 .8 18 .5 — 84 .8 16 .9 22 .8 85 .1 $4,575

PI144J AS480 12 401 21 .1 28 .5 85 21 .1 — 85 19 .3 26 85 .4 $4,730

PI144K AS480 12 421 24 33 84 .3 26 .8 — 84 .3 21 .6 29 85 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 26 .8 33 .5 81 .8 26 .8 — 81 .8 24 30 82 .5 $5,340

UCI224D SX460 12 583 32 40 84 .2 32 — 84 .2 28 35 84 .6 $5,800

UCI224E SX460 12 636 36 45 85 .4 36 — 85 .4 33 .5 42 85 .6 $6,195

UCI224F SX460 12 714 44 .8 56 86 .9 44 .8 — 86 .9 40 50 87 .1 $6,785

UCI224G SX460 12 798 50 62 .5 87 .3 50 — 87 .3 47 58 .8 87 .6 $7,175

UCI274C SX460 12 866 54 67 .5 86 .3 54 — 86 .3 46 .8 58 .5 86 .7 $8,135

UCI274D SX460 12 923 63 78 .8 87 .3 63 — 87 .3 57 .6 72 87 .6 $8,425

UCI274E SX460 12 1050 76 .8 96 88 .8 76 .8 — 88 .8 67 .2 84 89 .2 $9,380

UCI274F SX460 12 1148 87 108 .8 89 .6 87 — 89 .6 78 97 .5 89 .8 $10,330

UCI274G SX460 12 1259 98 .7 123 .4 89 .7 98 .7 — 89 .7 92 .6 115 89 .9 $10,840

UCI274H SX460 12 1352 114 142 .5 90 .7 114 — 90 .7 105 131 .3 90 .9 $11,650

UCDI274J SX460 12 1588 128 .8 161 89 .9 128 .8 — 89 .9 120 150 90 .1 $12,255

UCDI274K SX460 12 1665 140 175 90 .9 140 — 90 .9 128 160 91 .2 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 112 140 91 .8 112 — 91 .8 104 130 91 .8 $13,550

S4L1S-D4 MX341 12 2123 136 170 92 .2 136 — 92 .2 128 160 92 .3 $14,295

S4L1S-E4 MX341 12 2307 160 200 92 .8 160 — 92 .8 148 185 92 .9 $16,370

S4L1S-F4 MX341 12 2584 184 230 92 .8 184 — 92 .8 168 210 92 .8 $17,825

NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Weights are single bearing, packing excluded. 4. UCD274 available with SAE 1 or 2 only.5. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 20: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

20

INDUSTRIAL Voltage: 240/120 Only Winding 06 - 4 Wire Hz/RPM: 60/1800 Only Class H Insulation Phase/PF: 1 / 0.8-1.0 Connection: Series/Parallel

Model AVR Leads Wt. (Lbs)

150/40 Rise/Amb* 125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/AmbList PricekW

0.8PFkW

1.0PFEff.

1.0PFkW

0.8PFkW

1.0PFEff.

1.0PFkW

0.8PFkW

1.0PFEff.

1.0PFkW

0.8PFkW

1.0PFEff.

1.0PF

EB

S O

PT

ION

AL

PI044D AS480 4 161 5 .4 8 .1 69 .4 5 7 .5 72 5 7 .5 72 4 .6 6 .8 72 .5 $2,720

PI044E AS480 4 172 7 .2 10 .8 71 .4 6 .7 10 74 6 .7 10 74 6 .1 9 .1 74 .2 $3,000

PI044F AS480 4 192 9 13 .5 74 .8 8 .4 12 .5 77 .2 8 .4 12 .5 77 .2 7 .6 11 .3 77 .5 $3,175

PI044G AS480 4 207 10 .9 16 .2 77 .5 10 .1 15 80 10 .1 15 80 9 .2 13 .6 80 .1 $3,280

PI044H AS480 4 231 12 .6 18 .9 78 .5 11 .8 17 .5 80 .9 11 .8 17 .5 80 .9 10 .7 15 .9 81 $3,415

PI144D AS480 4 261 14 .6 22 .6 80 .5 13 .6 21 82 .3 13 .6 21 82 .3 12 .4 19 .1 83 .4 $3,540

PI144E AS480 4 293 18 .3 26 .9 81 .6 17 25 83 .5 17 25 83 .5 15 .5 22 .8 83 .9 $3,850

PI144F AS480 4 312 20 .2 29 .6 81 .9 18 .7 27 .5 83 .9 18 .7 27 .5 83 .9 17 25 84 $4,100

PI144G AS480 4 348 22 32 .3 83 .4 20 .4 30 85 20 .4 30 85 18 .7 27 .3 85 .1 $4,490

PI144H AS480 4 376 25 .5 37 .6 84 .1 23 .8 35 85 .8 23 .8 35 85 .8 21 .8 31 .9 85 .9 $4,575

PI144J AS480 4 401 30 43 85 .2 27 .3 40 86 .5 27 .3 40 86 .5 24 .9 36 .4 87 $4,730

PI144K AS480 4 421 30 .6 45 .2 86 .6 28 42 86 .9 28 42 86 .9 27 38 .2 87 .2 $4,865

PM

G O

PT

ION

AL

UCI224C AS440 4 550 34 43 83 .9 30 37 .5 84 .6 30 37 .5 84 .6 27 33 .8 85 $5,205

UCI224D AS440 4 583 40 50 86 35 .2 44 86 .5 35 44 86 .5 32 40 86 .8 $5,620

UCI224E AS440 4 636 46 57 .5 87 .2 40 50 87 .7 40 50 87 .7 37 .8 47 .3 87 .8 $5,960

UCI224F AS440 4 714 55 69 88 .4 48 60 88 .8 48 60 88 .8 45 .5 56 .9 88 .9 $6,520

UCI224G AS440 4 798 65 82 88 .6 56 75 89 56 75 89 52 .5 65 .6 89 .4 $6,890

UCI274C AS440 4 866 75 100 87 .3 67 .2 90 87 .8 67 .2 90 87 .8 60 75 88 .3 $7,955

UCI274D AS440 4 923 88 117 88 .4 76 .8 100 88 .8 76 .8 100 88 .8 70 87 .5 89 .2 $8,090

UCI274E AS440 4 1050 103 122 90 89 .6 115 90 .4 89 .6 115 90 .4 80 100 90 .6 $9,180

UCI274F AS440 4 1148 124 147 90 .6 108 135 90 .9 108 135 90 .9 100 125 91 .1 $10,125

UCI274G AS440 4 1259 138 162 90 .7 120 150 91 120 150 91 110 137 .5 91 .2 $10,410

UCI274H AS440 4 1352 144 172 91 .9 125 156 .3 92 .1 125 156 .3 92 .1 115 143 .8 92 .1 $11,390

UCDI274J — — — — — — — — — — — — — — — —

UCDI274K AS440 4 1665 — — — 160 200 91 .2 — — — 128 160 91 .5 $12,400

PM

G S

TD

S4L1S-E4 MX341 4 2307 170 212 93 .9 160 200 92 .2 160 200 92 .2 146 .4 183 93 .9 $16,370

S4L1S-F4 MX341 4 2584 212 265 93 .9 200 250 93 .9 200 250 93 .9 178 225 93 .9 $17,825

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* 150/40 RATING FOR UC RANGE LIMITED TO AMERICAS REGION NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. UCD274J not available. 4. UCD274K available with SAE 1 or 2 only.5. Weights are single bearing, packing excluded.6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

Page 21: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

21

INDUSTRIAL Voltage: 440 or 220Winding 311 - 12 wire Hz/RPM: 50/1500Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

Model AVR Leads Wt. (Lbs)

kVA / kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40

kVA kW kVA kW kVA kW kVA kW kVA kW

EB

S O

PT

ION

AL

PI044D AS480 12 161 7 .8 6 .2 7 .7 6 .2 7 .1 5 .7 7 .1 5 .7 6 .5 5 .2 $2,720

PI044E AS480 12 172 10 .5 8 .4 10 .3 8 .2 9 .5 7 .6 9 .5 7 .6 8 .6 6 .9 $3,000

PI044F AS480 12 192 13 .1 10 .5 12 .8 10 .2 11 .9 9 .5 11 .9 9 .5 10 .8 8 .6 $3,175

PI044G AS480 12 207 15 .7 12 .6 15 .4 12 .3 14 .3 11 .4 14 .3 11 .4 13 10 .4 $3,280

PI044H AS480 12 231 18 .3 14 .6 18 14 .4 16 .6 13 .3 16 .6 13 .3 15 .2 12 .2 $3,415

PI144D AS480 12 261 20 .9 16 .7 20 .4 16 .3 19 15 .2 19 15 .2 17 .3 13 .8 $3,540

PI144E AS480 12 293 26 .1 20 .9 25 .6 20 .5 23 .8 19 23 .8 19 21 .6 17 .3 $3,850

PI144F AS480 12 312 28 .7 23 28 .1 22 .5 26 .1 20 .9 26 .1 20 .9 23 .8 19 $4,100

PI144G AS480 12 348 31 .4 25 .1 30 .6 24 .5 28 .5 22 .8 28 .5 22 .8 26 .1 20 .9 $4,490

PI144H AS480 12 376 36 .6 29 .3 35 .6 28 .5 33 .3 26 .6 33 .3 26 .6 30 .4 24 .3 $4,575

PI144J AS480 12 401 42 .8 34 .2 41 .8 33 .4 38 30 .4 38 30 .4 34 .7 27 .8 $4,730

PI144K AS480 12 421 44 .5 35 .6 42 .8 34 .2 40 .4 32 .3 40 .4 32 .3 35 .6 28 .5 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 33 26 .4 31 .7 25 .4 30 24 30 24 27 21 .6 $5,340

UCI224D SX460 12 583 41 .2 33 39 .1 31 .3 37 .5 30 37 .5 30 33 .6 26 .9 $5,800

UCI224E SX460 12 636 47 .3 37 .8 45 .8 36 .6 45 36 45 36 40 .3 32 .2 $6,195

UCI224F SX460 12 714 60 .5 48 .4 58 46 .4 55 44 55 44 48 .7 39 $6,785

UCI224G SX460 12 798 80 .1 64 .1 76 .9 61 .5 75 60 75 60 67 .4 53 .9 $7,175

UCI274C

Special winding required. Consult factory.

UCI274DUCI274EUCI274FUCI274GUCI274HUCDI274J UCDI274K

PM

G S

TD

S4L1S-C4 MX341 12 1952 275 220 270 216 250 200 250 200 230 184 $13,550

S4L1S-D4 MX341 12 2123 320 256 310 248 290 232 290 232 270 216 $14,295

S4L1S-E4 MX341 12 2307 380 304 370 296 350 280 350 280 320 256 $16,370

S4L1S-F4 MX341 12 2584 440 352 430 344 400 320 400 320 370 296 $17,825

HCI534C MX341 12 2965 495 396 478 382 450 360 450 360 400 320 $20,390

HCI534D MX341 12 3254 530 424 515 412 500 400 500 400 450 360 $21,185

HCI534E MX341 12 3523 660 528 635 509 600 480 600 480 550 440 $24,895

HCI534F MX341 12 3840 715 572 690 552 650 520 650 520 600 480 $27,195

HCI634G MX321 12 4327 850 680 820 656 800 640 800 640 750 600 $33,080

HCI634H MX321 12 4658 960 768 920 736 875 700 860 688 800 640 $36,385

HCI634J MX321 12 5000 1100 880 1060 848 1000 800 950 760 900 720 $38,730

HCI634K MX321 12 5602 1220 976 1180 944 1110 888 1045 836 1000 800 $41,095

PI634G MX321 6 5860 1190 952 1170 936 1135 908 RTF RTF 1040 832 $43,575 PI734A MX321 6 6093 1323 1060 1287 1030 1238 988 1235 988 1152 920 $46,515PI734B MX321 6 6093 1470 1176 1430 1144 1375 1100 1375 1100 1280 1024 $47,460PI734C MX321 6 6692 1630 1304 1590 1272 1520 1216 1520 1216 1415 1132 $55,200PI734D* MX321 6 7325 1735 1388 1685 1348 1620 1296 1620 1296 1505 1204 $59,840PI734E MX321 6 7408 1995 1596 1940 1552 1865 1492 1865 1492 1735 1388 $66,710PI734F MX321 6 8477 2185 1748 2125 1700 2040 1632 2040 1632 1900 1520 $73,195PI734G MX321 6 8949 2310 1848 2250 1800 2160 1728 2160 1728 2005 1604 $81,360P80 LVSI804R DM110 6 12220 2490 1992 2420 1936 2265 1812 2265 1812 2075 1660 $155,990 P80 LVSI804S DM110 6 12327 2885 2308 2805 2244 2620 2096 2500 2000 2405 1924 $173,210 P80 LVSI804T DM110 6 13099 3150 2520 3065 2452 2865 2292 2770 2216 2630 2104 $198,115 P80 LVSI804W DM110 6 17457 — — 3570 2856 3340 2672 3173 2538 3122 2498 $252,650 P80 LVSI804X DM110 6 17587 — — 3970 3176 3675 2940 3525 2820 3435 2748 $288,505

NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET.3. Six wire machines are 440 Volts only and not

reconnectable to Delta.

4. Weights are single bearing, packing excluded.5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature

rise at 120 or below, and ambient up to 40.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY

Page 22: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

22

Model AVR Leads Wt. (Lbs)

kVA / kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40

kVA kW kVA kW kVA kW kVA kW kVA kW

EB

S O

PT

ION

AL

PI044D AS480 12 161 8 .3 6 .6 8 .1 6 .5 7 .5 6 7 .5 6 6 .8 5 .4 $2,720PI044E AS480 12 172 11 8 .8 10 .8 8 .6 10 8 10 8 9 .1 7 .3 $3,000PI044F AS480 12 192 13 .8 11 13 .5 10 .8 12 .5 10 12 .5 10 11 .4 9 .1 $3,175PI044G AS480 12 207 16 .5 13 .2 16 .2 13 15 12 15 12 13 .7 11 $3,280PI044H AS480 12 231 19 .3 15 .4 18 .9 15 .1 17 .5 14 17 .5 14 16 12 .8 $3,415PI144D AS480 12 261 22 17 .6 21 .5 17 .2 20 16 20 16 18 .2 14 .6 $3,540PI144E AS480 12 293 27 .5 22 26 .9 21 .5 25 20 25 20 22 .8 18 .2 $3,850PI144F AS480 12 312 30 .3 24 .2 29 .6 23 .7 27 .5 22 27 .5 22 25 20 $4,100PI144G AS480 12 348 33 26 .4 32 .3 25 .8 30 24 30 24 27 .5 22 $4,490PI144H AS480 12 376 38 .5 30 .8 37 .5 30 35 28 35 28 32 25 .6 $4,575PI144J AS480 12 401 45 36 44 35 .2 40 32 40 32 36 .5 29 .2 $4,730PI144K AS480 12 421 46 .8 37 .4 45 36 42 .5 34 42 .5 34 37 .5 30 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 47 37 .4 45 36 42 .5 34 42 .5 34 37 .5 30 $5,340UCI224D SX460 12 583 55 44 53 42 .4 50 40 50 40 45 36 $5,800UCI224E SX460 12 636 63 50 .4 61 48 .8 60 48 60 48 53 42 .4 $6,195UCI224F SX460 12 714 80 64 77 61 .6 72 .5 58 72 .5 58 65 52 $6,785UCI224G SX460 12 798 91 72 .6 87 .5 70 85 68 85 68 75 60 $7,175UCI274C SX460 12 866 110 88 106 84 .8 100 80 100 80 84 67 .2 $8,130UCI274D SX460 12 923 125 100 121 96 .8 114 91 .2 114 91 100 80 $8,425UCI274E SX460 12 1050 150 120 145 116 140 112 140 112 125 100 $9,380UCI274F SX460 12 1148 175 140 170 136 160 128 160 128 145 116 $10,330UCI274G SX460 12 1259 189 160 182 149 .6 175 145 .6 175 140 160 131 .7 $10,840UCI274H SX460 12 1352 220 176 212 169 .6 200 160 200 160 182 145 .6 $11,680UCDI274J SX460 12 1588 260 208 250 200 230 184 230 184 210 168 $12,255UCDI274K SX460 12 1665 275 220 265 212 250 200 250 200 229 183 .2 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 275 220 270 216 250 200 250 200 230 184 $13,550S4L1S-D4 MX341 12 2123 330 264 320 256 300 240 300 240 280 224 $14,295S4L1S-E4 MX341 12 2307 380 304 370 296 350 280 350 280 320 256 $16,370S4L1S-F4 MX341 12 2584 440 352 430 344 400 320 400 320 370 296 $17,825HCI534C MX341 12 2965 495 400 477 .5 382 450 364 450 360 400 320 $20,390HCI534D MX341 12 3254 530 440 515 412 500 400 500 400 450 360 $21,185HCI534E MX341 12 3523 660 528 636 509 600 480 600 480 550 440 $24,895HCI534F MX341 12 3840 737 .5 590 710 568 670 540 670 536 620 496 $27,195HCI634G MX321 12 4327 850 680 825 660 800 640 800 640 750 600 $33,080HCI634H MX321 12 4658 1000 800 960 768 910 728 910 728 830 664 $36,385HCI634J MX321 12 5000 1100 888 1070 856 1000 824 1000 800 900 720 $38,730HCI634K MX321 12 5602 1220 976 1180 944 1110 888 1110 888 1000 800 $41,095PI634G MX321 6 5860 1313 1050 1288 1030 1250 1000 RTF RTF 1146 917 $43,575 PI734A MX321 6 6093 1350 1080 1314 1052 1260 1008 1260 1008 1174 .5 940 .6 $46,515PI734B MX321 6 6093 1500 1200 1460 1168 1400 1120 1400 1120 1305 1044 $47,460PI734C MX321 6 6692 1660 1328 1615 1292 1550 1240 1550 1240 1445 1156 $55,200PI734D* MX321 6 7325 1770 1416 1720 1376 1650 1320 1650 1320 1535 1232 $59,840PI734E MX321 6 7408 2035 1628 1980 1584 1900 1520 1900 1520 1770 1416 $66,710PI734F MX321 6 8477 2230 1800 2170 1736 2080 1664 2080 1664 1935 1548 $73,195PI734G MX321 6 8949 2360 1888 2295 1836 2200 1760 2200 1760 2050 1640 $81,360P80 LVSI804R DM110 6 12220 2650 2120 2575 2060 2410 1928 — — 2210 1768 $155,990 P80 LVSI804S DM110 6 12327 3070 2456 2985 2388 2790 2232 — — 2560 2048 $173,210 P80 LVSI804T DM110 6 13099 3350 2680 3260 2608 3050 2440 — — 2800 2240 $198,115 P80 LVSI804W DM110 6 17457 3910 3128 3800 3040 3555 2844 — — 3322 2658 $252,650 P80 LVSI804X DM110 6 17587 4300 3440 4180 3344 3911 3129 — — 3655 2924 $288,505

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 400-415 Volts only and not reconnectable to Delta.4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

INDUSTRIAL Voltage: 400-415 or 200-208Winding 311 - 12 wire Hz/RPM: 50/1500Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

Page 23: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

23

INDUSTRIAL Voltage: 380 or 190Winding 311 - 12 wire Hz/RPM: 50/1500Winding 312 - 6 wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

Model AVR Leads Wt. (Lbs)

kVA / kW @ Temp. Rise / Ambient °C

List Price163/27 150/40 125/40 120/40 105/40

kVA kW kVA kW kVA kW kVA kW kVA kW

EB

S O

PT

ION

AL

PI044D AS480 12 161 8 .3 6 .6 8 .1 6 .5 7 .5 6 7 .5 6 6 .8 5 .4 $2,720PI044E AS480 12 172 11 8 .8 10 .8 8 .6 10 8 10 8 9 .1 7 .3 $3,000PI044F AS480 12 192 13 .8 11 13 .5 10 .8 12 .5 10 12 .5 10 11 .4 9 .1 $3,175PI044G AS480 12 207 16 .5 13 .2 16 .2 13 15 12 15 12 13 .7 11 $3,280PI044H AS480 12 231 19 .3 15 .4 18 .9 15 .1 17 .5 14 17 .5 14 16 12 .8 $3,415PI144D AS480 12 261 22 17 .6 21 .5 17 .2 20 16 20 16 18 .2 14 .6 $3,540PI144E AS480 12 293 27 .5 22 26 .9 21 .5 25 20 25 20 22 .8 18 .2 $3,850PI144F AS480 12 312 30 .3 24 .2 29 .6 23 .7 27 .5 22 27 .5 22 25 20 $4,100PI144G AS480 12 348 33 26 .4 32 .3 25 .8 30 24 30 24 27 .5 22 $4,490PI144H AS480 12 376 38 .5 30 .8 37 .5 30 35 28 35 28 32 25 .6 $4,575PI144J AS480 12 401 45 36 44 35 .2 40 32 40 32 36 .5 29 .2 $4,730PI144K AS480 12 421 46 .8 37 .4 45 36 42 .5 34 42 .5 34 37 .5 30 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 46 .75 37 .4 45 36 42 .5 34 42 .5 34 37 .5 30 $5,340UCI224D SX460 12 583 55 44 53 42 .4 50 40 50 40 45 36 $5,800UCI224E SX460 12 636 63 50 .4 61 48 .8 60 48 60 48 53 42 .4 $6,195UCI224F SX460 12 714 80 64 77 61 .6 72 .5 58 72 .5 58 65 52 $6,785UCI224G SX460 12 798 90 .75 72 .6 87 .5 70 85 68 85 68 75 60 $7,175UCI274C SX460 12 866 110 88 106 84 .8 100 80 100 80 84 67 .2 $8,130UCI274D SX460 12 923 125 100 121 96 .8 114 91 .2 120 96 100 80 $8,425UCI274E SX460 12 1050 150 120 145 116 140 112 140 112 125 100 $9,380UCI274F SX460 12 1148 175 140 170 136 160 128 160 131 .7 145 116 $10,330UCI274G SX460 12 1259 189 160 182 149 .6 175 149 .6 180 145 .6 160 131 .7 $10,840UCI274H SX460 12 1352 220 176 212 169 .6 200 160 200 160 182 145 .6 $11,680UCDI274J SX460 12 1588 260 208 250 200 230 184 230 184 210 168 $12,255UCDI274K SX460 12 1665 275 220 265 212 250 200 250 200 229 183 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 275 220 270 216 250 200 250 200 230 184 $13,550S4L1S-D4 MX341 12 2123 330 264 320 256 300 240 300 240 280 224 $14,295S4L1S-E4 MX341 12 2307 380 304 370 296 350 280 350 280 320 256 $16,370S4L1S-F4 MX341 12 2584 425 340 415 332 400 320 400 320 370 296 $17,825HCI534C MX341 12 2965 495 400 477 382 450 364 450 360 400 320 $20,390HCI534D MX341 12 3254 530 440 515 412 500 400 500 400 450 360 $21,185HCI534E MX341 12 3523 660 528 636 509 600 480 600 480 550 440 $24,895HCI534F MX341 12 3840 737 590 710 568 670 536 670 536 620 496 $27,195HCI634G MX321 12 4327 850 680 820 660 800 640 800 640 750 600 $33,080HCI634H MX321 12 4658 1000 800 960 768 910 728 910 728 830 664 $36,385HCI634J MX321 12 5000 1100 880 1060 848 1000 800 1000 800 900 720 $38,730HCI634K MX321 12 5602 1220 976 1180 944 1110 888 1110 888 1000 800 $41,095PI634G MX321 6 5860 1250 1000 1225 980 1190 952 RTF RTF 1091 873 $43,575 PI734A MX321 6 6093 1310 1048 1274 1020 1224 980 1225 980 1139 912 $46,515PI734B MX321 6 6093 1455 1164 1415 1132 1360 1088 1360 1088 1265 1012 $47,460PI734C MX321 6 6692 1610 1292 1570 1256 1505 1204 1505 1204 1400 1120 $55,200PI734D* MX321 6 7325 1715 1372 1670 1340 1605 1292 1615 1292 1490 1200 $59,840PI734E MX321 6 7408 1975 1580 1920 1536 1845 1476 1845 1476 1715 1372 $66,710PI734F MX321 6 8477 2165 1732 2105 1684 2020 1616 2020 1616 1880 1504 $73,195PI734G MX321 6 8949 2290 1832 2225 1780 2135 1708 2135 1708 1985 1588 $81,360P80 LVSI804R DM110 6 12220 2515 2012 2445 1956 2290 1832 — — 2100 1680 $155,990 P80 LVSI804S DM110 6 12327 2915 2332 2835 2268 2650 2120 — — 2430 1944 $173,210 P80 LVSI804T DM110 6 13099 3180 2544 3095 2476 2895 2316 — — 2660 2128 $198,115 P80 LVSI804W DM110 6 17457 — — 3610 2888 3375 2700 — — 3155 2524 $252,650 P80 LVSI804X DM110 6 17587 — — 3970 3176 3715 2972 — — 3470 2776 $288,505

NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET. 3. Six wire machines are 380 Volts only and not reconnectable to Delta.4. Weights are single bearing, packing excluded. 5. UCD274 available with SAE 1 or 2 only.6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY

Page 24: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

24

INDUSTRIAL Voltage: 220/110Winding 311 - 12 wire Hz/RPM: 50/1500Class H Insulation Phase/PF: 1 / 0.8-1.0 Connection: Double Delta

Model AVR Leads Wt. (Lbs)125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/Amb

List PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

EB

S O

PT

ION

AL

PI044D AS480 12 161 3 .6 5 .4 74 3 .6 5 .4 74 3 .3 4 .9 74 .5 $2,720PI044E AS480 12 172 4 .8 7 .2 76 .2 4 .8 7 .2 76 .2 4 .4 6 .6 76 .7 $3,000PI044F AS480 12 192 6 9 78 6 9 78 5 .4 8 .2 78 .5 $3,175PI044G AS480 12 207 7 .2 10 .8 78 .4 7 .2 10 .8 78 .4 6 .6 9 .8 79 $3,280PI044H AS480 12 231 8 .4 12 .6 79 .6 8 .4 12 .6 79 .6 7 .7 11 .5 80 .2 $3,415PI144D AS480 12 261 9 .6 13 82 .2 9 .6 13 82 .2 8 .7 11 .8 82 .5 $3,540PI144E AS480 12 293 12 16 .2 82 12 16 .2 82 11 14 .8 82 .4 $3,850PI144F AS480 12 312 13 .2 17 .8 83 .5 13 .2 17 .8 83 .5 12 16 .2 83 .9 $4,100PI144G AS480 12 348 14 .4 19 .4 83 .8 14 .4 19 .4 83 .8 13 .2 17 .8 84 .2 $4,490PI144H AS480 12 376 16 .8 22 .7 84 .8 16 .8 22 .7 84 .8 15 .4 20 .7 85 .2 $4,575PI144J AS480 12 401 19 .2 25 .9 85 19 .2 25 .9 85 17 .5 23 .7 85 .4 $4,730PI144K AS480 12 421 20 .4 30 .2 84 .9 22 .4 30 .2 84 .9 18 .4 27 85 .5 $4,865

PM

G O

PT

ION

AL

UCI224C SX460 12 550 22 .8 28 .5 86 .4 22 .8 28 .5 86 .4 20 25 82 .6 $5,340UCI224D SX460 12 583 26 .8 33 .5 87 .2 26 .8 33 .5 87 .2 24 30 83 .6 $5,800UCI224E SX460 12 636 32 40 87 .8 32 40 87 .8 28 .4 35 .5 84 .5 $6,195UCI224F SX460 12 714 38 .8 48 .5 89 .3 38 .8 48 .5 89 .3 34 .8 43 .5 86 .2 $6,785UCI224G SX460 12 798 45 .2 56 .5 89 .4 45 .2 56 .5 89 .4 40 50 86 .4 $7,175UCI274C SX460 12 866 48 60 90 .2 48 60 90 .2 40 50 87 .4 $8,130UCI274D SX460 12 923 54 .4 68 90 .5 54 68 90 .5 48 60 87 .9 $8,425UCI274E SX460 12 1050 68 85 91 .4 68 85 91 .4 60 75 88 .9 $9,380UCI274F SX460 12 1148 76 .8 96 91 .8 76 .8 96 91 .8 69 .6 87 89 .5 $10,330UCI274G SX460 12 1259 86 .4 105 92 .1 86 .4 105 92 .1 79 96 89 .8 $10,840UCI274H SX460 12 1352 96 120 92 .7 96 120 92 .7 88 110 90 .7 $11,680UCDI274J SX460 12 1588 110 .4 138 89 .5 110 .4 138 89 .5 100 .8 127 89 .7 $12,255UCDI274K SX460 12 1665 120 150 90 .3 120 150 90 .3 109 .6 137 .5 90 .6 $12,400

PM

G S

TD

S4L1S-C4 MX341 12 1952 100 125 91 .9 100 125 91 .9 92 115 92 $13,550S4L1S-D4 MX341 12 2123 120 150 92 120 150 92 112 140 92 .1 $14,295S4L1S-E4 MX341 12 2307 140 175 92 .5 140 175 92 .5 128 160 92 .5 $16,370S4L1S-F4 MX341 12 2584 160 200 92 .4 160 200 92 .4 148 185 92 .4 $17,825HCI534C MX341 12 2965 144 180 93 .5 144 180 93 .5 128 160 93 .5 $20,390HCI534D MX341 12 3254 160 200 93 .8 160 200 93 .8 144 180 93 .7 $21,185HCI534E MX341 12 3523 192 240 94 .2 192 240 94 .2 176 220 94 .1 $24,895HCI534F MX341 12 3840 212 265 94 .2 212 265 94 .2 196 245 94 .2 $27,195

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET.3. Weights are single bearing, packing excluded.4. UCD274 available with SAE 1 or 2 only.5. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

Page 25: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

25

INDUSTRIAL Voltage: 220/110 ONLYWdg. 05 - 4 Wire Hz/RPM: 50/1500 ONLYClass H Insulation Phase/PF: 1 / 0.8-1.0 Connection: Series/Parallel

Model AVR Leads Wt. (Lbs)125/40 Rise/Amb 120/40 Rise/Amb 105/40 Rise/Amb

List PricekW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

kW 0.8PF

kW 1.0PF

Eff 1.0PF

EB

S O

PT

ION

AL

PI044D AS480 4 161 4 6 70 .8 4 6 70 .8 3 .7 5 .5 71 .6 $2,720PI044E AS480 4 172 5 .4 8 71 .8 5 .3 8 71 .8 4 .9 7 .3 72 .6 $3,000PI044F AS480 4 192 6 .7 10 .1 75 .1 6 .7 10 .1 75 .1 6 .1 9 .1 75 .9 $3,175PI044G AS480 4 207 8 .1 12 .1 78 .3 8 .0 12 .1 78 .3 7 .4 11 79 $3,280PI044H AS480 4 231 9 .4 14 78 .8 9 .3 14 78 .8 8 .6 12 .8 79 .5 $3,415PI144D AS480 4 261 10 .9 14 .7 81 10 .8 14 .7 81 9 .9 13 .4 81 .5 $3,540PI144E AS480 4 293 13 .6 18 .4 81 .3 13 .6 18 .4 81 .3 12 .4 16 .7 81 .9 $3,850PI144F AS480 4 312 15 20 .2 82 .1 14 .9 20 .2 82 .1 13 .6 18 .4 82 .6 $4,100PI144G AS480 4 348 16 .3 22 84 .5 16 .3 22 84 .5 15 20 .2 84 .9 $4,490PI144H AS480 4 376 19 25 .7 84 .9 19 .0 25 .7 84 .9 17 .4 23 .5 85 .2 $4,575PI144J AS480 4 401 21 .8 29 .4 85 .4 21 .7 29 .4 85 .4 19 .9 26 .9 85 .7 $4,730PI144K AS480 4 421 22 .8 30 .8 85 .4 22 .8 30 .8 85 .4 20 27 85 .7 $4,865

PM

G O

PT

ION

AL

UCI224C AS440 4 550 22 .4 28 84 .8 22 .4 28 84 .8 20 25 85 .2 $5,205UCI224D AS440 4 583 28 35 86 .4 28 35 86 .4 25 .2 31 .5 86 .7 $5,620UCI224E AS440 4 636 32 40 87 .6 32 40 87 .6 28 .8 36 87 .8 $5,960UCI224F AS440 4 714 40 50 88 .5 40 50 88 .5 36 45 88 .7 $6,520UCI224G AS440 4 798 48 60 88 .8 48 60 88 .8 43 .2 54 89 $6,890UCI274C AS440 4 866 52 .8 66 87 .9 52 .8 66 87 .9 48 60 88 .2 $7,955UCI274D AS440 4 923 59 .2 74 88 .9 59 .2 74 88 .9 53 66 .3 89 .1 $8,090UCI274E AS440 4 1050 75 .2 94 90 .1 75 .2 94 90 .1 67 .2 84 90 .3 $9,180UCI274F AS440 4 1148 88 110 90 .6 88 110 90 .6 80 100 90 .8 $10,125UCI274G AS440 4 1259 96 120 90 .7 96 120 90 .7 86 .4 108 90 .8 $10,410UCI274H AS440 4 1352 112 140 91 .6 112 140 91 .6 100 125 91 .7 $11,390

NOTES:1. List price adder: PMG/MX341 - $880 PMG/MX321 - $12852. EBS adder for P0/P1 frames is $130 NET.3. Weights are single bearing, packing excluded. 4. UCD274 available with SAE 1 or 2 only.5. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 26: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

26

INDUSTRIAL Voltages: As listed6 Pole Hz/RPM: 60/1200 - 50/1000 Winding 311 - 12 Wire Phase/PF: 3/0.8Winding 312 - 6 Wire Connection: WYE Class H Insulation

60 Hz, 1200 RPM, 440V-480V Wt.(Lbs.)

kW @ Temp. Rise/Ambient Deg C ListPrice Model AVR Leads 163/27 150/40 125/40 105/40 80/40

PM

G S

TD

HCI636G MX321 12 3688 300 291 280 260 224 $37,720HCI636H MX321 12 4145 406 395 380 350 300 $41,400HCI636J MX321 6 4309 482 468 450 420 360 $44,355HCI636K MX321 12 5086 610 594 570 525 448 $47,305PI736B MX321 6 5916 752 728 700 652 564 $61,795PI736D MX321 6 7136 984 960 920 852 736 $70,795PI736F MX321 6 8190 1392 1352 1300 1200 1040 $90,775

NOTES:1 Prices applicable to both 1 & 2 bearing. 2 Weights are single bearing, packing excluded. 3 For 600 V machines (Wdg 07), use 480 V ratings and prices.4 12 lead machines are reconnectable to low wye (Parallel Star).5 6 wire not reconnectable to Delta.6. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

60 Hz, 1200 RPM, 416V Wt.(Lbs.)

kW @ Temp. Rise/Ambient Deg C ListPrice Model AVR Leads 163/27 150/40 125/40 105/40 80/40

PM

G S

TD

HCI636G MX321 12 3688 283 275 265 245 208 $37,720HCI636H MX321 12 4145 386 374 360 330 280 $41,400HCI636J MX321 6 4309 454 442 425 400 344 $47,790HCI636K MX321 12 5086 578 562 540 500 440 $47,305PI736B MX321 6 5916 696 676 652 600 520 $61,795PI736D MX321 6 7136 900 876 840 776 672 $70,760PI736F MX321 6 8190 1284 1248 1200 1100 956 $90,775

50 Hz, 1000 RPM, 380V-440V Wt.(Lbs.)

kW @ Temp. Rise/Ambient Deg C ListPrice Model AVR Leads 163/27 150/40 125/40 105/40 80/40

PM

G S

TD

HCI636G MX321 12 3688 240 233 224 208 180 $37,720HCI636H MX321 12 4145 326 316 304 280 240 $41,400HCI636J MX321 6 4309 386 374 360 336 288 $47,790HCI636K MX321 12 5086 488 474 456 420 360 $47,305PI736B MX321 6 5916 600 584 560 520 452 $61,795PI736D MX321 6 7136 788 768 736 680 592 $70,760PI736F MX321 6 8190 1112 1084 1040 960 832 $90,775

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 27: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

27

MARINE Voltages: As listedWinding 311 - 12 Wire Hz/RPM: 50/1500 & 60/1800 Winding 312 - 6 Wire Phase/PF: 3/0.8Class H Insulation Connection: WYE

MARINE SPECIFICATION: All machines include:1. IP23 dripproof marine compliance (60 Deg from Vertical).2. Anti-condensation heater (Specify Voltage – 120 or 240V).3. EBS (PO/P1 frames) or PMG fitted for 300% short circuit current.

4 POLE, 3 PHASEkW @ 0.8 PF

50Hz 1500 RPM 60Hz 1800 RPM 60Hz 1800 RPM ListPrice90 / 50 110 / 50 90 / 50

MODEL AVR 380 415 416 440 460 480 416 440 460 480

PM044D AS480 4 .8 4 .8 5 .8 6 .2 6 .5 6 .6 5 .3 5 .6 5 .8 6 $3,410

PM044E AS480 6 .4 6 .4 7 .8 8 .3 8 .6 8 .9 7 7 .5 7 .8 8 $3,705

PM044F AS480 8 8 9 .8 10 .4 10 .8 11 8 .8 9 .4 9 .8 10 $3,885

PM044G AS480 9 .6 9 .6 11 .7 12 .5 12 .9 13 .3 10 .6 11 .3 11 .7 12 $3,995

PM044H AS480 11 .2 11 .2 13 .6 14 .6 15 15 .4 12 .3 13 .2 13 .6 14 $4,135

PM144D AS480 12 .8 12 .8 15 .6 16 .6 17 .1 17 .7 14 .1 15 15 .5 16 $4,305

PM144E AS480 16 16 19 .4 20 .8 21 .4 22 .1 17 .6 18 .8 19 .4 20 $4,625

PM144F AS480 17 .6 17 .6 21 .4 22 .8 23 .5 24 .3 19 .4 20 .6 21 .3 22 $4,845

PM144G AS480 19 .2 19 .2 23 .4 25 25 .8 26 .6 21 .1 22 .6 23 .3 24 $5,255

PM144H AS480 22 .4 22 .4 27 .3 29 .1 30 31 24 .6 26 .3 27 .1 28 $5,340

PM144J AS480 25 .6 25 .6 31 .1 33 .3 34 .3 35 .4 28 .2 30 .1 31 32 $5,500

PM144K AS480 27 .2 27 .2 35 .4 37 .1 37 .1 38 .9 32 33 .6 33 .6 35 .2 $5,640

UCM224C MX341 28 28 35 35 .8 35 .8 37 .2 31 .5 33 .5 34 .5 34 .5 $6,850

UCM224D MX341 32 32 40 .8 42 .5 43 .4 45 38 40 41 41 $7,310

UCM224E MX341 38 38 48 50 .4 50 .4 52 .8 43 45 47 47 $7,705

UCM224F MX341 46 46 58 60 .5 60 .5 64 52 .5 55 57 .5 57 .5 $8,295

UCM224G MX341 52 52 67 .6 69 .6 72 .8 73 .6 60 63 65 65 $8,685

UCM274C MX341 62 62 75 82 82 87 72 74 78 78 $9,640

UCM274D MX341 70 70 92 94 96 100 86 88 90 90 $9,935

UCM274E MX341 90 90 108 110 112 115 .2 100 105 110 110 $10,890

UCM274F MX341 108 108 125 130 134 135 120 124 .8 130 .4 130 .4 $11,840

UCM274G MX341 119 .2 119 .2 149 .1 154 .2 154 .2 164 .6 136 .6 148 .8 151 .2 151 .2 $12,350

UCM274H MX341 136 136 170 175 177 180 160 170 175 175 $13,190

UCM274J — — — — — — — — — — — —

UCM274K MX341 156 160 201 212 220 228 200 212 216 212 $13,910

S4L1M-C4 MX341 168 168 204 208 212 216 192 196 200 204 $14,335

S4L1M-D4 MX341 184 184 236 244 256 264 204 216 224 236 $15,080

S4L1M-E4 MX341 220 220 272 280 292 296 252 260 272 276 $17,155

S4L1M-F4 MX341 248 248 316 324 332 340 292 300 304 316 $18,610

HCM534C MX341 292 304 370 388 412 416 345 360 380 385 $21,240

HCM534D MX341 324 344 400 416 436 456 370 390 405 425 $22,035

HCM534E MX341 380 404 485 500 510 520 450 470 475 485 $25,745

HCM534F MX341 404 432 530 555 565 580 495 515 525 530 $28,045

HCM634G MX321 504 540 630 650 685 700 585 610 640 655 $34,005

HCM634H MX321 560 592 708 745 776 795 655 690 720 740 $37,310

HCM634J MX321 648 680 825 850 890 920 765 790 830 850 $39,655

HCM634K MX321 720 752 920 960 990 1020 850 890 920 945 $42,020

PM734A MX321 720 764 — — — — 812 880 896 936 $47,495

PM734B MX321 764 832 — — — — 888 936 976 1024 $48,440

PM734C MX321 944 1012 — — — — 1112 1184 1208 1232 $56,180

PM734D* MX321 1004 1076 — — — — 1184 1264 1288 1316 $60,820

PM734E MX321 1092 1192 — — — — 1352 1440 1472 1500 $67,690

PM734F MX321 1200 1312 — — — — 1528 1628 1660 1696 $74,175

PM734G MX321 1392 1436 — — — — 1616 1724 1760 1796 $82,340

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

* AVAILABLE IN SINGLE BEARING ONLY NOTES:1. Prices applicable to both 1 & 2 bearing.2. 12 lead stators to HCM634K, 6 lead above.3. For weights, consult factory.4. For other voltages, consult factory.5. 110/50, 90/50 is temperature rise over ambient in deg °C.6. All machines listed on this page are available as CLASSIFIED MARINE. Consult your sales representative for details.

Page 28: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

28

MARINE AGENCY CERTIFICATIONSCERTIFICATION CHARGE (LIST PRICE)

kW RANGE ABS LLOYDS DNV BV G. Lloyds

PM044-PM144 $3,065 $2,135 $1,895 $2,105 $2,540

UCM 224 $3,320 $2,595 $2,635 $2,595 $2,675

UCM 274 $3,710 $3,265 $3,075 $3,240 $4,745

S4 M $4,330 $3,685 $3,710 $3,635 $5,550

HCM 5 $4,880 $4,100 $4,385 $4,020 $6,495

HCM 6 $6,000 $4,980 $5,705 $4,835 $7,430

PM 7 $7,675 $5,760 $6,810 $5,470 $9,395

P80 (2000kW) RTF RTF $17,355 RTF RTF

P80 (3000kW) RTF RTF $23,450 RTF RTF

RTF: Refer to Factory .

NOTES:1. Certification charge include a witnessed test, heat run, certificate and inspector’s fees when conducted

within our factory. For societies not listed, refer to factory.2. ABS & Lloyds require Temp. Detectors above 400 kW, 500 kVA. See accessories page 39.3. Certified shaft steel with agency certification only.4. Consult factory for lead time.5. Certification from: CCS, KRS, NKK, RINA & RMRS available upon request.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

MARINE Voltages: As listed6 POLE Hz/RPM: 60/1200Winding 311 - 12 Wire Phase/PF: 3/0.8Winding 312 - 6 Wire Connection: WYEClass H Insulation

6 POLE, 3 PHASE 110 Deg C Rise 90 Deg C Rise, List

PricekW @ 0.8 PF 50 Deg C Ambient 50 Deg C Ambient

Model AVR Leads Wt. (Lbs) 416 440 460 480 416 440 460 480

HCM636G MX321 12 3688 235 250 250 250 235 250 250 250 $41,200

HCM636H MX321 12 4145 314 332 332 332 310 330 330 330 $45,230

HCM636J MX321 6 4309 380 400 400 400 380 400 400 400 $48,225

HCM636K MX321 12 5086 475 500 500 500 475 500 500 500 $51,385

PM736B MX321 6 5916 — — — — 568 600 600 600 $66,615

PM736D MX321 6 7136 — — — — 736 780 780 780 $76,095

PM736F MX321 6 8190 — — — — 908 960 960 960 $96,190

NOTES:1. Prices applicable to both 1 and 2 bearing.2. Weights are single bearing, packing excluded.3. For 50hz, 1000 rpm ratings, refer to factory.

Page 29: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

29

INDUSTRIAL Voltages: 4160 & 3300Medium Voltage Hz/RPM: 60/1800 - 50/1500Class F Insulation Phase/PF: 3/0.8Class H Insulation Connection: WYE

4160/2400V, 60 HZ, 1800 RPMWt. (Lbs.)

kW @ Temp Rise/Ambient Deg CList

Price Model Insulation Class AVR Leads 125/40 105/40 80/40

PM

G S

TD

MVWI 734E F MX321 6 5688 — 1000 880 $105,785

MVWI 734F F MX321 6 6371 — 1250 1100 $111,810

MVWI 734G F MX321 6 7606 — 1500 1320 $127,115

MVWI 734H F MX321 6 8333 — 1750 1540 $142,765

DIG120k/4 F DM110 6 15940 — 2000 1830 $165,177

DIG130h/4 F DM110 6 16878 — 2200 2000 $216,123

DIG130i/4 F DM110 6 18485 — 2400 2216 $226,189

MVSI804R H DM110 6 12220 2520 2304 2016 $236,840

MVSI804S H DM110 6 12327 2824 2600 2256 $265,225

MVSI804T H DM110 6 13099 3120 2904 2540 $295,280

MVSI804W H DM110 6 17457 3595 3360 2920 $316,200

MVSI804X H DM110 6 17587 4152 3880 3372 $349,890

3300/1900V, 50 HZ, 1500 RPMWt. (Lbs.)

kW @ Temp Rise/Ambient Deg CList

Price Model Insulation Class AVR Leads 125/40 105/40 80/40

PM

G S

TD

MVWI 734E F MX321 6 5688 — 800 700 $105,785

MVWI 734F F MX321 6 6371 — 1000 880 $111,810

MVWI 734G F MX321 6 7606 — 1200 1050 $127,115

MVWI 734H F MX321 6 8333 — 1400 1230 $142,765

DIG120k/4 F DM110 6 15940 — 1640 1440 $165,177

DIG130h/4 F DM110 6 16878 — 1800 1584 $216,123

DIG130i/4 F DM110 6 18485 — 2080 1830 $226,189

MVSI804R H DM110 6 12220 2120 1920 1680 $236,840

MVSI804S H DM110 6 12327 2320 2128 1864 $265,225

MVSI804T H DM110 6 13099 2528 2352 2060 $295,280

MVSI804W H DM110 6 17457 2974 2780 2491 $316,200

MVSI804X H DM110 6 17587 3402 3180 2850 $349,890

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE . NOTES:1. Prices applicable to both 1 & 2 bearing. 2. Isolation transformer (3 Phase) included. 3. 2-RTD’s/phase (100 ohm Platinum) included. 4. Other 60 HZ Voltages to order: 4160V Delta, 3300V & 2400V Wye.5. Weights are single bearing, packing excluded. 6. Anti-condensation heater included (Specify Voltage). 7. Over-voltage excitation circuit breaker std. 8 For delta connection, please refer to the factory.

MV7 - P80 Range

Page 30: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

30

Model AVR Leads Wt.(Lbs.)

7200 Volts Wdg 71List

PricekW @ Temp Rise/Ambient C

125/40 105/40 80/40

PM

G S

TD

HVSI804R DM110 6 12200 2460 2300 2008 $249,295

HVSI804S DM110 6 12327 2688 2512 2200 $275,080

HVSI804T DM110 6 13099 3020 2824 2464 $309,575

HVSI804W DM110 6 17457 3592 3360 2928 $333,875

HVSI804X DM110 6 17587 4064 3800 3304 $356,225

Model AVR Leads Wt.(Lbs.)

11,400 Volts Wdg 81List

PricekW @ Temp Rise/Ambient C

125/40 105/40 80/40

PM

G S

TD

HVSI804R DM110 6 12200 2216 2070 1824 $262,110

HVSI804S DM110 6 12327 2452 2294 2004 $289,250

HVSI804T DM110 6 13099 2768 2590 2280 $325,565

HVSI804W DM110 6 17457 3312 3112 2704 $350,925

HVSI804X DM110 6 17587 3760 3536 3072 $374,465

Model AVR

12,470 Volts Wdg 87 13,200 Volts Wdg 91 13,800 Volts Wdg 91List

PricekW @ Temp Rise/Ambient C kW @ Temp Rise/Ambient C kW @ Temp Rise/Ambient C

125/40 105/40 80/40 125/40 105/40 80/40 125/40 105/40 80/40

DIG130i/4 DM110 — 2132 1876 — 2257 1986 — 2360 2077 $241,843

PM

G S

TD

HVSI804R DM110 2272 2120 1844 2176 2028 1764 2272 2120 1844 $262,110

HVSI804S DM110 2472 2320 2028 2456 2296 1992 2560 2400 2100 $289,250

HVSI804T DM110 — — — 2700 2524 2192 2824 2640 2304 $325,565

HVSI804W DM110 — — — 3032 2848 2480 3168 2979 2592 $350,925

HVSI804X DM110 — — — 3436 3224 2800 3592 3371 2928 $374,465

NOTES:1. All machines are 6 lead. 2. Prices applicable to both 1 & 2 bearing. 3 Weights are two bearing, packing excluded. Consult factory for single bearing weights. 4. Pricing includes anti-condensation heaters and 2-RTD’s/Phase (100 ohm Platinum).5. Model DIG130i/4 - no reference to winding number

INDUSTRIAL Voltages As listed High Voltage Hz/RPM 60/1800 Class F Insulation Phase/PF 3/0.8 Connection: WYE

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

P80 Range

Page 31: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

31

INDUSTRIAL Voltages As listed High Voltage Hz/RPM 50/1500 Class F Insulation Phase/PF 3/0.8 Connection: WYE

NOTES:1. All machines are 6 lead. 2. Prices applicable to both 1 & 2 bearing. 3. Weights are two bearing, packing excluded. Consult factory for single bearing weights. 4. Pricing includes anti-condensation heaters and 2-RTD’s/Phase (100 ohm Platinum).

6000 Volts Wdg 71 & 6600 Volts Wdg 61 6300 Volts Wdg 61

ListPrice

kVA/kW @ Temp. Rise/Ambient C kVA/kW @ Temp. Rise/Ambient C

125/40 105/40 80/40 125/40 105/40 80/40

PM

G S

TD

Model AVR kVA kW kVA kW kVA kW kVA kW kVA kW kVA kW

HVSI804R DM110 2400 1920 2250 1800 1950 1560 2291 1833 2148 1718 1861 1489 $249,295

HVSI804S DM110 2695 2156 2520 2016 2200 1760 2573 2058 2405 1924 2100 1680 $275,080

HVSI804T DM110 3075 2460 2875 2300 2480 1984 2935 2348 2744 2195 2368 1894 $309,575

HVSI804W DM110 3640 2912 3410 2728 2970 2376 3475 2780 3255 2604 2835 2268 $333,875

HVSI804X DM110 4140 3312 3875 3100 3370 2696 3952 3162 3699 2959 3226 2581 $356,225

10,000 Volts Wdg 81 10,500 Volts Wdg 83

ListPrice

kVA/kW @ Temp. Rise/Ambient C kVA/kW @ Temp. Rise/Ambient C

125/40 105/40 80/40 125/40 105/40 80/40

PM

G S

TD

Model AVR kVA kW kVA kW kVA kW kVA kW kVA kW kVA kW

HVSI804R DM110 2430 1944 2270 1816 2000 1600 2320 1856 2168 1734 1909 1527 $262,110

HVSI804S DM110 2690 2152 2515 2012 2200 1760 2568 2054 2401 1921 2100 1680 $289,250

HVSI804T DM110 3035 2428 2840 2272 2500 2000 2897 2318 2711 2169 2386 1909 $325,565

HVSI804W DM110 3630 2904 3410 2728 2960 2368 3312 2650 3111 2489 2701 2161 $350,925

HVSI804X DM110 4120 3296 3875 3100 3370 2696 3780 3024 3555 2844 3093 2474 $374,465

11,000 Volts Wdg. 83

ListPrice

kVA/kW @ Temp. Rise/Ambient C

Wt.(Lbs)

125/40 105/40 80/40

PM

G S

TD

Model AVR Leads kVA kW kVA kW kVA kW

HVSI804R DM110 6 12220 2430 1944 2270 1816 2000 1600 $262,110

HVSI804S DM110 6 12327 2690 2152 2515 2012 2200 1760 $289,250

HVSI804T DM110 6 13099 3035 2428 2840 2272 2500 2000 $325,565

HVSI804W DM110 6 17457 3470 2776 3259 2607 2830 2264 $350,925

HVSI804X DM110 6 17587 3960 3168 3724 2979 3240 2592 $374,465

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

P80 Range

Page 32: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

32

P80 Product Range

■ P80 is a range of 4-pole, single or two bearing AVR controlled alternators

■ Engine adaptors to SAE 00,0 and coupling discs to SAE 18, 21 & 24 are offered for P80

■ Windings offered are 6 wire

■ Low voltage range available up to 690V

■ Medium voltage range available up to 4160V

■ High voltage range available up to 13800V

■ IP23 enclosure protection as standard

Low Voltage Industrial Class “H” Continuous Ratings (kW)

Stator Winding Type 50Hz 60Hz

P80 LVSI804 4 pole Random / Wire 1,812 - 2,940 2,080 - 3,571

Medium Voltage Industrial Class “H” Continuous Ratings (kW)

Stator Winding Type 50Hz 60Hz

P80 MVSI804 4 pole Form / Bar 2,120 - 3,402 2,520 - 4,152

High Voltage Industrial Class “F” Continuous Ratings (kW)

Stator Winding Type 50Hz 60Hz

P80 HVSI804 4 pole Form / Bar 1,718 - 3,100 1,920 - 3,800

Image courtesy of B

roadcrown Ltd H

ixon

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

USA_PricingGuide2018_2COL_Pages.indd 6 03/11/2017 08:38

Page 33: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

33• NOTE: ALL DIMENSIONS MILLIMETRES • SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

S0L2 SERIES

S0L1 Series Dimensions

Model A B C X

SAE

3, 4

, 5

S0L1 - D1 405 .5 212 167 197

S0L1 - H1 440 .5 247 202 215

S0L1 - J1 440 .5 247 202 212

S0L1 - L1 485 .5 292 235 243

S0L1 - P1 485 .5 292 235 236

S0L1 - S1 485 .5 292 235 233

S0L2 Series Dimensions

Model A B C X

SAE

3, 4

, 5

S0L2 - F1 459 .5 257 211 211

S0L2 - G2 459 .5 257 211 211

S0L2 - K1 479 .5 277 222 222

S0L2 - M1 494 .5 292 230 230

SOL2 - P1 514 .5 312 240 240

SOL2 - U1 544 .5 342 255 255

S1L2 Series Dimensions

Model A B C X

SAE

4, 5

S1L2 - G1 531 .5 276 .5 231 260

S1L2 - H1 531 .5 276 .5 231 256

S1L2 - J1 531 .5 276 .5 231 252

S1L2 - K1 551 .5 296 .5 251 263

S1L2 - N1 571 .5 316 .5 270 271

S1L2 - R1 591 .5 336 .5 281 281

S1L2 - Y1 661 .5 406 .5 310 312

S1L2 SERIES

Reference only - Dimensions not for construction

CRITICAL DIMENSIONSSTAMFORD PRODUCTS

S0L1 SERIES DIMENSIONS

Page 34: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

34

A (WITH PMG)

B (WITHOUT PMG)

A (WITH PMG)

• NOTE: ALL DIMENSIONS MILLIMETRES • SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

*UCD274J & UCD274K DO NOT HAVE AN OPTION FOR SAE3 ADAPTER . . . ONLY SAE 1 AND SAE 2

P0/P1 Series Dimensions

Model A B C D E F

044D, E 446 364 203 160 254 292

044F, G 481 399 203 160 254 292

044H 496 414 203 160 254 292

144D 521 439 238 180 279 319

144E 566 484 238 180 279 319

144F 581 499 238 180 279 319

144G 621 539 238 180 279 319

144H 646 564 238 180 279 319

144J 676 594 238 180 279 319

144K 691 609 238 180 279 319

P0-P1 SERIES

UCI SERIES UCI SERIES DIMENSIONS

Model A B C D E F G H IS

A E

1 224C, D 724 661 191 311 690 224 452 406 356

224E, F 814 751 191 311 690 224 452 406 356

224G 859 796 191 311 690 224 452 406 356

S A

E 2,3

,4 224C, D 710 647 177 311 690 224 452 406 356

224E, F 800 737 177 311 690 224 452 406 356

224G 845 782 177 311 690 224 452 406 356

S A

E 1

274C, D 813 750 216 406 774 270 538 466 406

274E, F 928 865 216 406 774 270 538 466 406

274G 978 915 216 406 774 270 538 466 406

274H 1018 955 216 406 774 270 538 466 406

UCD274J, K 1063 1000 202 406 774 270 530 466 406

S A

E 2

& 3

274C, D 799 736 202 406 774 270 538 466 406

274E, F 914 851 202 406 774 270 538 466 406

274G 964 901 202 406 774 270 538 466 406

274H 1004 941 202 406 774 270 538 466 406

UCD274J, K* 1063 1000 202 406 774 270 530 466 406

HCI, S4 & P SERIES HCI, S4 & PI7 SERIES DIMENSIONS

MODEL A B C D E F G H I J

S4C, D, E 1207 1100 232 — 457 315 632 852 508 578

4F 1297 1190 232 — 457 315 632 852 508 578

S4G 1292 1221 232 — 457 315 617 852 508 641

5C, D, E 1369 1262 297 — 500 355 712 971 610 670

5F 1444 1377 297 — 500 355 712 971 610 670

6G,H,J 1548 — 350 350 560 400 786 1148 686 786

6K 1649 — 350 350 560 400 786 1148 686 786

P6G 1679 — 350 350 560 400 772 1148 686 786

P7B, C 1643 — 365 435 630 450 970 1280 750 870

P7D, E 1793 — 365 435 630 450 970 1280 750 870

P7F 1878 — 365 435 800 450 970 1280 750 870

P7G 1940 — 365 435 800 450 970 1280 750 870

D C

G

F

E

I

H

B (WITHOUT PMG)

D CE J

I

G

H

F

Reference only - Dimensions not for construction

CRITICAL DIMENSIONSSTAMFORD PRODUCTS

Page 35: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

35

1 BEARINGA C E F G H I J

804R 1891 269 1297 500 1345 1497 910 1461

804S 1891 269 1297 500 1345 1497 910 1461

804T 1891 269 1297 500 1345 1497 910 1461

NOTE: Dimensions apply to LV804-MV804-HV804 frames

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

P80 RANGE LVSI804/MVSI804/HVSI804

P80 RANGE LVSI804/MVSI804/HVSI804

2 BEARINGA C E F G H I J

804R 2112 490 1297 500 1345 1497 910 1461

804S 2112 490 1297 500 1345 1497 910 1461

804T 2112 490 1297 500 1345 1497 910 1461

804W 2510 573 1612 500 1345 1497 910 1461

804X 2510 573 1612 500 1345 1497 910 1461

804Y 2510 573 1612 500 1345 1497 910 1461

A

E C

G

J

I

H

F

A

E C

G

H

F

J

I

Reference only - Dimensions not for construction

CRITICAL DIMENSIONS P80 RANGE

Page 36: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

36

ASSISTANCE WITH DIFFICULT OR HARSH ENVIRONMENTS INDUSTRIAL & MARINE

STAMFORD Industrial and Marine generators are designed for operation in clean dry conditions . Humidity may be present, however, condensation and/or water (both fresh and saline) together with contamination, will severely reduce the alternator’s useful life .

Insulation systems are designed for 100,000 hours of life in ideal conditions . Real life conditions limit the machine life based on how well the machine is protected and maintained .

Harsh environments, both on and off shore, require special consideration . Rock crushers, crane drives, mines, barges, and platforms are some examples .

We can advise the genset assembler on ways to protect the generator from adverse environments .

In addition to our standard level of insulation we offer an alternative . Selection of this option should be made in conjunction with your sales representative .

Level 2: Certain stationary windings receive an additional coating or alternate environmental treatments . Polyester and/or epoxy are used based on frame size . Air filters and heaters are optional accessories .

Level 3: In addition to level 2, level 3 requires that all metal surfaces are specially treated to resist corrosion . Air filters and heater are standard . Air filters require a derate, consult factory .

Harsh Environment Protection – List Price

Frame S0/S1 P0/P1 UC22/27 S4S/HC5 S4D HC 6* P7*

Level 2 N/A $935 $970 $1,070 N/A $1,160 $1,370

Level 3 N/A — $2,460 $3,355 N/A $3,720 N/A

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

*AVAILABILITY SUBJECT TO APPLICATION REVIEW

Page 37: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

37

UL COMPLIANT GENERATORS

STAMFORD generators in select frame sizes are now UL1004 recognized and can be used in UL 2200 applications .

All STAMFORD generators can be UL recognized and labeled with the addition of a UL compliant Voltage Regulator . UL compliant versions of our standard Voltage Regulators include the AS440–UL and the PMG excited MX341–UL .

With the addition of the UL compliant AVR, the generators in the frames below can be labeled UL 1004 compliant . Standard generators in stock at our distribution facility can either be upfitted with the compliant AVR, wiring harnesses, labels, etc . or shipped with no Voltage Regulator to meet the requirements of UL 1004 .

UL compliant generators are rated up to 120 degree C rise over 40 degree C ambient .

Pricing for UL 1004 compliant generators is as follows:Generator Frame From Standard To UL Compliant List Price

UC224–UC274 SX460–AS440 AS440UL No Charge

UC224–UC274 SX460–AS440 MX341-UL plus PMG No Charge

S4–HC 5 MX341 MX341-UL No Charge

**UC224–UC274 No AVR No AVR No Charge

S4–HC 5 No AVR No AVR RTF

HC6, P7, P80 RTF RTF RTF

HC6, P7, P80 RTF RTF RTFRTF: Refer to Factory .

UL 1004 recognition will facilitate the use of STAMFORD generators by generator set manufacturers for UL 2200 applications .

* P0-P1 FRAMES SOLD IN THE AMERICAS ARE UL1004 COMPLIANT AT NO CHARGE

**THERE IS NO DEDUCTION AVAILABLE FOR A UL 1004 CERTIFIED GENERATOR SUPPLIED WITHOUT A VOLTAGE REGULATOR .

NOTE: AS440-UL AND MX341-UL HAVE THE SAME ELECTRICAL PERFORMANCE AS THE NON UL COMPLIANT VERSIONS.

Page 38: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

• Standard • Optional 1 - Ratings for guidance only

Robustly engineered products, alternators are specifically designed to meet the challenges of the most

arduous applications and environments – be it in extraction of oil, gas, coal and minerals, UPS systems,

critical marine power to tankers and container vessels, or by providing dependable power with prime

movers like diesel engines, gas engines and steam turbines.

■ 4-pole to 10-pole alternators

■ 480kW to 6,800kW with voltage up to 690V

■ 480kW to 8,800kW with voltage of 3.3 kV to 13.8 kV

■ Brushless and self excitation

■ IP23, IP54, IP55, enclosure protection

■ Suitable for use with all kinds of prime movers: reciprocating engines, gas and steam turbines

www.stamford-avk.com For more information visit:

Pow

er R

atin

gs -

kW

(50

/60H

z)Cl

ass

‘F’ r

ise

Volta

ges

Low

vol

tage

400

up

to 6

90 V

Med

ium

/Hig

h vo

ltage

3,3

- 1

3,8k

V

Spee

ds

4-po

le 1

500/

1800

min

-1

6-po

le 1

000/

1200

min

-1

8-po

le 7

50/9

00 m

in-1

10-p

ole

600/

720

min

-1

Bear

ings

Sta

ndar

d an

ti-fri

ctio

n be

arin

gs

Flan

ged

slee

ve b

earin

gs

Encl

osur

e an

d co

olin

g

IP23

0 S

OLA

S/IC

OA

1

IP 4

4 A

ir in

-out

let fi

lters

IC11

/21/

31 c

oolin

g op

tions

Wat

er-c

oolin

g C

AC

W/IC

81W

/IP44

+

Air-

cool

ing

CA

CA

/IC61

6/IP

44+

DS

G

DSG 62 520 - 1,056 • • • • • • • •

DSG 74 480 - 1,920 • • • • • • • • • • •

DSG 86 536 - 2,720 • • • • • • • • • • • •

DSG 99 976 - 4,240 • • • • • • • • • • • •

DSG 114 1,664 - 4,752 • • • • • • • • • • •

DSG 125 690V only 3,360 - 6,800 • • • • •

DSG 144 690V only 5,040 • • • •

DIG

DIG 110 Upto 11kV only 448 - 1,040 • • • • • • • • • •

DIG 120 Upto 11kV only 704 - 2,080 • • • • • • • • • •

DIG 130 912 - 3,200 • • • • • • • • • • •

DIG 140 1,440 - 4,240 • • • • • • • • • • •

DIG 142 3,008 - 5,360 • • • •

DIG 150 2,240 - 6,480 • • • • • • • • • • •

DIG 156 2,840 - 8,800 • • • • • • • • • • • •

USA_PricingGuide2018_2COL_Pages.indd 1 03/11/2017 08:37

Page 39: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

4 and 6 pole land-based drilling alternators for drill rig power and camp power (auxiliaries)

AvK alternators are amongst the most arduous and reliable in the market, resulting in superior

uptime for our customers

DSG 86 and 99Alternators for Oil and Gas Drilling Rigs

Power Range:

DSG 86 - Up to 1300kWe (1860kVA) @ 0.7 p.f.

DSG 99 - Up to 1365kWe (1950kVA) @ 0.7 p.f.

Cont. Class B (80°C) temp rise, 50°C ambient.

Voltage Range: 400V/480V/600V/690V (50 or 60Hz)

Speed: 1000-1800rpm (4 & 6-Pole)

Enclosure: IP23 with water droplet capture filters on air inlet.

Construction: IMB20 (2-Bearing)

Stator Winding:Fully taped form wound stator (offering enhanced environment protection and high protection against load induced harmonics)

USA_PricingGuide2018_2COL_Pages.indd 2 03/11/2017 08:37

Page 40: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

40

INDUSTRIAL Voltages: As listed2 POLE Hz/RPM: 50/3000–60/3600 Winding 311, 06 & 05 Phase/PF: 1 & 3/1.0 & 0.8 Class H Insulation Connection: ALL

2 POLE, 3 PHASEWINDING 311

kW, 0.8 PF, 50/3000 kW, 0.8 PF, 60/3600List

Price125/40 105/40 125/40 120/40 105/40

Model AVR Leads Wt. 440 415-380 440 415-380 480-440 416 480-440 416 480-440 416

PI042D AS480 12 164 9 .7 10 8 .8 9 .2 11 .7 11 11 .6 11 .0 10 .6 9 .9 $2,830

PI042E AS480 12 181 11 .7 12 10 .6 10 .8 14 .1 13 .3 14 .0 13 .2 12 .6 11 .9 $3,120

PI042F AS480 12 194 13 .6 14 12 .1 12 .8 16 .1 15 .2 16 .0 15 .2 14 .5 13 .7 $3,300

PI042G AS480 12 205 15 .5 16 14 14 .4 18 .6 17 .6 18 .6 17 .6 16 .8 15 .8 $3,410

PI142D AS480 12 261 19 .4 20 17 .6 18 21 .2 20 21 .2 20 19 .1 18 $3,680

PI142E AS480 12 293 21 .4 22 19 .2 20 26 .3 24 .8 26 .3 24 .8 23 .7 22 .3 $4,005

PI142F AS480 12 312 24 .8 25 .6 22 .6 23 .4 29 .7 28 29 .6 28 26 .7 25 .2 $4,265

PI142G AS480 12 348 29 .1 30 26 .4 27 .6 33 .9 32 33 .9 32 30 .6 28 .8 $4,675

PI142H AS480 12 376 31 32 28 28 .8 39 .8 37 .6 39 .8 37 .6 35 .8 33 .8 $4,755

PI142J AS480 12 401 35 36 31 .4 32 .4 42 .4 40 42 .4 40 38 .2 36 $4,920

NOTES:1. Prices applicable to both 1 & 2 bearing. 2. Weights are single bearing, packing excluded.3. EBS adder for P0/P1 frames is $130 NET.4. For UL1004 ratings refer to columns of temperature rise at 120 or below, and ambient up to 40.

2 POLE, 1 PHASEWinding 06- 60Hz;Winding 05- 50 Hz

kW, 1.0 PF, 50/3000 kW, 1.0 PF, 60/3600List

Price125/40 120/40 105/40 125/40 120/40 105/40

Model AVR Leads Wt. 110/220 110/220 110/220 120/240 120/240 120/240

PI042D AS480 4 164 8 .4 6 .7 7 .5 9 .4 7 .5 8 .4 $2,830

PI042E AS480 4 181 10 .1 8 .0 9 11 .3 9 .0 10 .2 $3,120

PI042F AS480 4 194 11 .7 9 .3 10 .6 12 .9 10 .3 11 .6 $3,300

PI042G AS480 4 205 13 .4 10 .7 12 15 12 13 .5 $3,410

PI142D AS480 4 261 16 .8 13 .4 15 17 13 .6 15 .3 $3,680

PI142E AS480 4 293 18 .4 14 .7 16 .6 21 .1 16 .8 19 $4,005

PI142F AS480 4 312 21 .4 17 .1 19 .3 23 .8 19 21 .4 $4,265

PI142G AS480 4 348 25 .1 20 .0 22 .5 27 .2 21 .7 24 .5 $4,675

PI142H AS480 4 376 26 .8 21 .4 24 32 25 .6 28 .8 $4,755

PI142J AS480 4 401 30 .2 24 .1 27 .2 34 27 .2 30 .6 $4,920

2 POLE, 1 PHASEWINDING 311

kW, 1.0 PF, 50/3000 kW, 1.0 PF, 60/3600List

Price125/40 120/40 105/40 125/40 120/40 105/40

Model AVR Leads Wt. 110/220 110/220 110/220 120/240 120/240 120/240

PI042D AS480 12 164 7 .5 6 7 8 .2 6 .5 7 .4 $2,830

PI042E AS480 12 181 9 7 .2 8 .3 9 .9 7 .9 8 .9 $3,120

PI042F AS480 12 194 10 .5 8 .4 9 .6 11 .3 9 .0 10 .2 $3,300

PI042G AS480 12 205 12 9 .6 10 .8 13 .1 10 .4 11 .8 $3,410

PI142D AS480 12 261 15 12 13 .8 14 .8 11 .8 13 .4 $3,680

PI142E AS480 12 293 16 .5 13 .2 15 18 .4 14 .7 16 .6 $4,005

PI142F AS480 12 312 19 .2 16 17 .6 20 .8 16 .64 18 .7 $4,265

PI142G AS480 12 348 22 .5 18 20 .7 23 .7 18 .96 21 .4 $4,675

PI142H AS480 12 376 24 19 .2 21 .6 27 .9 22 .32 25 .1 $4,755

PI142J AS480 12 401 27 21 .6 24 .3 29 .7 23 .76 26 .7 $4,920

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 41: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

41

* FOR SPECIFIC APPLICATIONS, CONSULT FACTORY .

RAIL POWER

Specific models of STAMFORD alternators have been designed to meet the requirements of traction applications, for switching and line haul locomotives .

Emissions requirements have promoted the use of multiple engine gensets, driven by emission certified truck engines, typically rated 500kW, and operating over variable speeds .

The alternators are usually custom engineered to meet both mechanical and electrical specifications; however we have established certain criteria to be supplied as a minimum .

Alternator controls can be provided by the locomotive manufacturer, or by us – dependent upon the application .

Rail specification features:

External

No terminal box

Extended leads (rail spec)

No PMG/AVR

Special drive end bracket

Special fan

Cable glands

Internal

Rotor shrink collars

Tighter interference fit between core and shaft

Modified rectifier assembly

Strengthened exciter stator (VPI epoxy impregnation)

Added insulation / taping in main stator . Double VPI epoxy impregnation .

Typical OutlineMODEL HCI504D, 400KW (480V)

MODEL HCI504E, 500KW (480V OR 600V)

MODEL HCI504F, 600KW (480V)

Page 42: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

42

Ready to SupportGrid Code Compliance

Cummins Generator Technologies is leading the way in developing Grid Code compatible generators

to enable customers to develop Grid Code compliant generating-sets. In fact, and

generators are helping customers meet the new requirements, supporting the delivery of more economic

and environmentally friendly power to users for the long term.

Tomorrow’s power generation solutions from Cummins Generator Technologies are being designed to meet

international Grid Code requirements. Furthermore, our customers can also be confident that compatible

products will be available in time for local legislation.

Blazing the Grid Code Trail

Cummins Generator Technologies is

committed to taking a strong lead in

supporting the development of Grid Codes

and Grid Code compatible machines for

power generation. Here are just some of the

ways in which we are contributing:

■ Participation in industry bodies

■ White papers and presenting at International

Conferences on Grid Code compliant

technology

■ Tracking country and regional Grid Code

developments in over 16 countries

The Cummins Generator Technologies

Advantage

The industry’s technology leader, we have

invested several years researching and also

developing Grid Code compatible generators,

committing substantial resources to ensure our

customers can supply Grid Code compliant

generating sets in advance of the new legislation.

Our expertise in power generation

machinery and the technology

enhancements required for Grid Codes,

puts us in an ideal position to supply

compatible generators.

USA_PricingGuide2013_2COL_Pages.indd 4 22/11/2012 16:19

Page 43: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

P6 - 1,210kW Alternator

The STAMFORD P6 - 1,210kW alternator boasts an advanced electromagnetic design

and highly effective cooling system in a compact package, resulting in lower weight

and superior performance.

4-pole alternator designed specifically for standby and island mode operation

Rated: 1,000kW – 400V/50Hz 1,210kW – 480V/60Hz

FeaturesandBenefits:

■ Typical operating efficiences of > 95%

■ 2/3 winding pitch minimising excessive neutral currents

■ Single or double bearings

■ Standard maintenance-free sealed bearings

■ IP23 enclosure protection

■ MX321 AVR and PMG excitation

■ Three-phase sensing detection and voltage regulation

■ Coupling options: SAE 0, 00, 18, 21 and 24

OptionsandAccessories:

■ RTDs for windings and bearings

■ Anti-condensation heaters

■ Air inlet filter (IP23)

■ Droop CT for parallel operation with other alternators (island mode operation)

■ RFI suppressors

■ Detection module of diode failure

■ Excitation loss module

■ Re-greasable bearings

USA_PricingGuide2016_2COL_Pages.indd 3 30/11/2015 15:01

Page 44: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

44

Marine Product Offerings

Our marine alternators are designed to offer efficient power generation with superior durability and reliability. Whether newbuild or repower, Cummins Generator Technologies can provide the optimum solution to meet your requirements. All and machines meet the classification requirements of all major marine societies.

Features ■ Standard IP23 Marine Protection

■ Standard Anti Condensation Heaters

■ Closed Air Cooling Available for AvK Products

■ IP44, IP54 and IP55 also offered in AvK range

■ IP23 with Dip Proof Offering

Additional options are available on request.

STAMFORD Marine Range

High-quality, durable alternators utilising wire-

wound technology for marine main power and

auxiliary generator sets and shaft alternators: ■ 4-6 pole / 1,000 - 1,800 rpm

■ Power range: 4 kW - 2,200 kW

■ Voltage range: 220 - 690V at 50 & 60Hz

AvK Marine Range

Robustly engineered bar wound alternator

designed to meet the challenges of the most

arduous applications and environments. AvK

alternators can be customised to meet specific

customer needs: ■ 4-10 pole / 600 - 1,800 rpm

■ Power range: 800 kW - 10,000 kW

■ Voltage range: 380 - 13,800V at 50 & 60Hz

USA_PricingGuide2018_2COL_Pages.indd 3 03/11/2017 08:37

Page 45: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

45

Marine Product Offerings

Our marine alternators are designed to offer efficient power generation with superior durability and reliability. Whether newbuild or repower, Cummins Generator Technologies can provide the optimum solution to meet your requirements. All and machines meet the classification requirements of all major marine societies.

Features ■ Standard IP23 Marine Protection

■ Standard Anti Condensation Heaters

■ Closed Air Cooling Available for AvK Products

■ IP44, IP54 and IP55 also offered in AvK range

■ IP23 with Dip Proof Offering

Additional options are available on request.

STAMFORD Marine Range

High-quality, durable alternators utilising wire-

wound technology for marine main power and

auxiliary generator sets and shaft alternators: ■ 4-6 pole / 1,000 - 1,800 rpm

■ Power range: 4 kW - 2,200 kW

■ Voltage range: 220 - 690V at 50 & 60Hz

AvK Marine Range

Robustly engineered bar wound alternator

designed to meet the challenges of the most

arduous applications and environments. AvK

alternators can be customised to meet specific

customer needs: ■ 4-10 pole / 600 - 1,800 rpm

■ Power range: 800 kW - 10,000 kW

■ Voltage range: 380 - 13,800V at 50 & 60Hz

USA_PricingGuide2018_2COL_Pages.indd 3 03/11/2017 08:37

and marine alternators can be found operating on vessels across all our oceans, seas and waterways.

■ Diesel-electric propulsion systems

■ Power Take Out/Power Take in (PTO/PTI) shaft alternators operating as auxiliary propulsion drive system

■ PTO shaft alternators for economical generation of electrical power

■ Self-starting Power Take Home (PTH) shaft alternators for emergency propulsion

■ Auxiliary and onboard power supply

■ Compliant to Fixed Water Based Local Application Fire Fighting Systems (FWBLAFFS)

■ Compliant to Safety of Life at Sea (SOLAS)

■ Diesel Electric Propulsion

■ PTO/PTI/PTH

■ Dynamic Positioning

■ Hybrid System

Marine Auxilary

■ Auxiliary Power

■ Service Alternators

■ Emergency Alternators

Marine Propulsion / Shaft Alternator

USA_PricingGuide2018_2COL_Pages.indd 4 03/11/2017 08:38

Page 46: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

ACCESSORY PRICES

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

46

List Pricing

ACCESSORIES MECHANICAL (M) S0 S1 P0 P1 UC22 UC27 S4S S4D HC5 HC6 P7 MV7 P80

M1. Drip proof

IP 23 Industrial (Standard)

IP 23 Marine Louvers (60 Degree)(5% Derate) STD STD $320 $320 $380 $445 $500 $535 $535 $2,060

M2. Close-Coupled Adaptor - 2 Brg . — — $425 $425 $465 $500 $935 — $1,090 $1,525 $1,635 $1,635 $3,045

M3. Side Foot Mounting — — — — — — — RTF — $1,390 $1,565 $1,565 $2,060

M4. Air Filters (Derate output 5%) — — — — $1,430 $1,430* $1,720 — $1,875 $2,185 $2,435 $3,200$12,140

M5. Export Box $195 $195 $195 $195 $235 $330 $380 $380 $425 $790 $1,070 $1,070 $1,500

M6. Vibration Monitor Mounting Pad — — — — — — — — — — — — $1,670

M7. Regreaseable Bearings (per bearing) — — — — — — — — $750 $750 $750 STD STD

M8. GM Adaptor — — $335 $335 $415 $415 — — — — — — —

*Airfilters not available for UC27 J&K cores

ACCESSORIES ELECTRICAL (E)E1. Anti-Condensation Heaters (120 or 240 Volt) $280 $280 $280 $280 $310 $310 $405 $405 $405 $425 $445 STD STD

E2. AVR & PMG Upgrades

AS480 AS480 + EBS — — $130 NET

$130 NET — — — — — —

SX460 AS440 — — — — $300 $300 — — — —

MX341 & PMG — — — — $880 $880 — — — —

MX321 & PMG — — — — $1,285 $1,285 — — — —

MX341 & PMG AS440 — — — — — — ($380) ($380) ($380) —

MX341 MX321 — — — — $405 $405 $405 $405 $405 —

MX341 DM110 — — — — — — RTF — $4,995 —

MX321 DM110 — — — — — — — — — $4,995 $4,995 RTF STD

AVR Deduct (STD AVR) RTF RTF ($145) ($145) ($145) ($145) — — — —

AVR & PMG Deduct — — — — — — ($350) RTF ($350) ($405) ($405) ($405) N/A

AVR PERFORMANCEAS480 SX460 AS440** MX341** MX321** AS540 DM110 DECS100

Voltage Regulation +/- 1% +/- 1 .5% +/- 1% +/- 1% +/- .5% +/- 1% +/-0 .5% +/- 0 .5%

Phases Sensed 1 Ph 1 Ph 1 Ph 1 Ph 3 Ph 1 Ph 1/3 Ph 1/3 Ph

Adjustable UFRO Knee STD STD STD STD STD STD STD STD

Variable UFRO Slope Fixed Fixed Fixed STD STD Fixed STD STD

Parallel Operation OPT No OPT OPT OPT No STD STD

Current Forcing OPT* No No STD STD OPT*** STD STD

PMG Input OPT* No No STD STD No STD STD

Overvoltage Protection No No No No STD No STD STD

Overexcitation Shutdown Yes No Yes STD STD STD STD STD

Dwell Feature No No No No STD No STD STD

Short Circuit Current Limit No No No No OPT No STD STD

* P0/P1 frames require Excitation Boost System (EBS) to enable current forcing. Standard PMG system is not suitable for these frames.** AS440–UL, MX341–UL & MX321-UL have the same electrical performance as the non UL compliant versions. *** S0/S1 frames require auxilliary windings to enable current forcing.

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

RTF: Refer to Factory • STD: Standard

STD: Standard • OPT: Optional

Page 47: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

ACCESSORY PRICES

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

47

ACCESSORIES ELECTRI-CAL (E)

List Pricing

S0 S1 P0 P1 UC22 UC27 S4 HC5 HC6 P7 MV7 P80

E3. Detectors.

All RTD’s are 3 Wire, 100 ohm Platinum

Bearing RTD DE or NDE — — — — — — $1,025 $1,025 $1,025 $1,430 $1,430 $1,670

Main Stator RTD’s

2 Per Phase — — $2,645 $2,645 $2,645 $2,645 $2,645 $2,645 $2,645 $2,645 STD STD

Thermistors - 3 Per Set* — — — — $455 $455 $455 $455 $455 $455 — —

Thermistor Control — — — — $690 $690 $690 $690 $690 $690 — —

E4. Excitation Circuit Breaker — — — — $195 $195 $195 $195 $195 $195 $195 $195

E5. Paralleling.

All AVR’s except SX460

3 Phase Reactive Droop — — $405 $405 $405 $405 $405 $405 $405 $405 $445 —

1 Phase Reactive Droop — — $510 $510 — — — — — —

E6. Remote Rheostat $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 STD STD

E7. Radio FrequencyInterference

RFI Suppression Module — — $290 $290 $290 $290 $290 $290 $290 $290 $380 $465

Mil Std 461C Shielding Kit — — — — $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100

E8. Short Circuit Control

MX321/341/AS540/ DM110/320/MA330/ DECS100 AVR Only

— — — — $905 $905 $905 $905 $905 $905 $1,060 RTF

E9. Electronic Modules

MVR1 (Man/Auto) with PMG machines Only — — — — $1,150 $1,150 $1,150 $1,150 $1,150 $1,150 $1,150 $2,070

VAR/PF Control- (PFC3) — — — — $1,710 $1,710 $1,710 $1,710 $1,710 $1,710 $2,050 INCL2

RCI-Remote Control Interface — — — — $1,555 $1,555 $1,555 $1,555 $1,555 $1,555 $2,070 INCL

Diode Fault Detector-DFD-1 — — — — — — — — — — $1,960 $1,960

Frequency Detection Module

FDM-1 12 or 24 V — — — — $625 $625 $625 $625 $625 $625 $625 $625

Excitation Loss Module

ELM-1 12 or 24 Volt — — — — $405 $405 $405 $405 $405 $405 $545 $625

Dual AVR- Manual Switching

(MX321 AVR Only) — — — — $2,830 $2,830 $2,830 $2,830 $2,830 $2,830 $3,885 $8,265

E10. Instruction Manuals $60 $60 $60 $60 $60 $60 $80 $80 $80 $80 $80 $195

E11. Cogeneration Spec. (addition to list price) — — — — — — — — 7% 7% — —

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

RTF: Refer to Factory • STD: Standard • INCL: Included

* Customer must specify class for H temperature ratings, and alarm or trip requirement.

NOTES:1. Accessories prices above apply when requested and installed on the machine at the factory

level when purchased. Contact Factory for pricing on spare parts.2. Power Factor Control capability is included in the DM110 AVR and can be enabled and

configured through the BestComs software.

Page 48: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

48

ACCESSORY DESCRIPTION

ACCESSORIES - ELECTRICAL (E) E1. Anti-Condensation Heaters • Prevents condensation from forming within the machine where temperature and humidity

changes are prevalent . Available at 120 or 240 Volt (Must Specify) . Cartridge type . Remote connection box included . All can be retrofitted on site .

Frame size S0L1 S0L2 S1L2 P0 P1 UC22 UC27 S4S S4D HC5 HC6 P7 P80

Anti-Cond . Heater

Watts at 120 Volts AC 30 45 80 30 30 110 110 195 225 285 285 285 1758

Watts at 240 Volts AC 30 45 80 30 30 114 114 170 225 255 255 255 1758

Watts at 12V DC 30 45 80 225

Watts at 24V DC 30 45 80 225

E2. AVR & PMG Modifications • Price is an adder to upgrade from standard AVR when ordered with alternator . For three phase sensing use SX421, or MX321 AVR’s .

E3. Detectors • All embedded Resistance Temperature Detectors are 3 wire, 100 Ohm Platinum . Stator RTD’s are available two per phase only . Thermistors are one per phase at standard temperatures . Thermistor control unit has a form C dry contacts . All RTD’s and Thermistors are factory installed only . Factory lead time applies .

E4. Excitation Circuit Breaker • For use with MX321, MA330 or SX421 . Can also be used as a manual excitation on/off switch . The

breaker is not a current operated device . It is tripped by the overvoltage module within the regulator . E5. Paralleling • Paralleling option permits the paralleling of two or more alternators . Droop or cross current compensation is available . Cross

current compensation requires sensing isolation and identical AVR systems . CT’s are bus bar mounted . Can be retrofitted on site . E6. Rheostat, Remote Voltage Adjust • 1K ohm potentiometer for use with AS480, SX460, AS440, and MX341 AVR’s . 4 .7K ohm

potentiometer is supplied for SX421, MX321 and MA330 AVR’s .

E7. RFI Suppression • Module exceeds commercial standards . MIL 461C Class 2 requires MX AVR’s, RFI module and shielded cables for PMG and exciter leads .

E8. Short Circuit Control • For use with MX320/MX321/MA330 AVR’s only . Provides adjustment to regulate amount of short circuit

current . Limits fault current for line-to-ground, line-to-line and 3 phase faults . Three transformers required, one per phase, mounted on the main terminal bus bars .

E9. ELECTRONIC MODULES • Supplied loose, steel case enclosed for switchgear mounting. Manual Voltage Regulator • Model MVR-1 . Switch selectable Manual-Off-Auto operation . Permits variable voltage starting of

large motors eliminating the need for reduced voltage starters . Provides controlled short circuit for removing moisture from windings . Requires PMG .

VAR/PF Controller • Model PFC3 . Permits paralleling with an infinite bus; i .e ., utility . Allows control of KVAR or Power Factor

within preset limits . A droop CT must be fitted with this device . Diode Fault Detector • Model DFD-1 . Detects short or open circuit diodes . Prevents alternator overheating due to faulty diodes .

Selectable 12-24VDC or 120-240VAC operation . Normally open or normally closed dry contacts for warning signal . Frequency Detection Module • Model FDM-1 . Provides for crank disconnect and overspeed protection . 12 or 24 VDC operation

from engine battery . For use with PMG excitation systems only . Excitation Loss Module • Model ELM-1 . Detects loss of AVR output to exciter . Allows detection and elimination of high circulating

currents when one machine in parallel operation loses excitation . Suitable for use with STAMFORD AVR’s only . 12 or 24VDC operation . Dual AVR Assembly • Provides second AVR which can be manually switched if main AVR fails . Both AVR’s are mounted on a steel

base and prewired . The switch must be wired on site together with the assembly within the switch gear . E10. Instruction Manuals • Extra manuals are available in English, Spanish and French .

E11. Cogeneration Spec • Special winding and insulation processes for frames HCI634 and PI734 for utility paralleling .

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Watts per cartridge

Page 49: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

ACCESSORIES MECHANICAL (M)M1. Dripproof • UC, HC, P7 and P80 frames comply with IP23 as standard .

M2. Close-Coupled Adaptor • Allows the direct connection of a 2 bearing generator to the flywheel housing for accurate alignment . Coupling not included . Consult factory for sizes available .

M3. Side Foot Mounting • Available on frames 4 and up . Feet to match CAT 3500 factory rails available .

M4. Air Filters • Provides protection from dust, sand and airborne abrasive materials . UCI line are foam washable type . HC line are made from a compound material and are cleaned by blowing air through them . All air filters are not retrofittable . You must derate the output of the alternator by 5% when air filters are used .

M5. Export Box • Individual crating suitable for export shipping .

M6. Vibration Monitor Position • Specifically machined surfaces for the purpose of mounting vibration monitors . Consult factory for available positions .

M7. Regreaseable Bearings • Available as an option on HCI534, HCM534, HCI634, HCM634, PI734 and PM734 .

M8. GM Adaptor • Allows direct adaption to GM engines eliminating the need for SAE components .

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

49

ACCESSORY DESCRIPTION

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 50: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

50

NON LINEAR LOADS (NLL)Alternator loads involving phase controlled electronic power devices such as thyristors introduce distortion to the generated wave form . Typical phase controlled loads are uninterruptible power supplies (UPS), the converter/inverter power units associated with variable speed drives (VSD), and electronic soft start modules .

Most alternators produced today can cope with high levels of wave form distortion without detrimental effects to themselves . However, there will be a problem with electronic power devices and AVR control systems trying to cope with highly distorted wave forms .

To establish acceptable levels of wave form distortion it is important to know the type of NLL to be powered . The following minimum information is generally required:

1 . Number of system pulses: Usually 6 or 12 .

2 . Level of Total Harmonic current Distortion (THD) produced by the NLL . Typically 30% 6 Pulse, 14% 12 Pulse .

3 . Are distortion filters installed? The answer to #2 will provide some guidance to this question .

4 . What is the maximum acceptable level of voltage distortion the NLL can accept?

5 . Operating voltage and frequency .

6 . If NLL power requirement is stated in kw, some guidance regarding operating power factor and system efficiency is required to establish the input kVA, therefore alternator load .

In the case of UPS systems, information is required regarding whether the battery charging facility is to be operational or inhibited while the UPS is being powered by the generating set . An operational battery charging system will increase the input to the UPS system; total input kVA to the UPS needs to be established .

Electronic soft starter modules incorporate power electronic devices which control the level of initial voltage applied to the motor’s wind-ings, which in turn reduces the motor’s inrush current . Once the motor is up to rated speed, the power electronics are by-passed, leaving the motor directly connected to the local electrical supply . This type of motor starter generates harmonic current distortion and thus is considered a non-linear load . Soft starters typically limit the inrush current and thus the impact kVA that the generator must supply . The impact kVA will be the motor’s run kVA times the current limiting factor (i .e . 1 .5 for 150% current limit, 2 .0 for 200% current limit, etc .)

As a general rule, we recommend limiting the direct axis sub transient reactance (x”d) due to the SCR portion of the load . The following recommendations apply:

For 12 pulse filtered UPS loads, limit x”d to 12%, or to the 105 °C rating of the alternator, whichever is the lower .

For 6 pulse filtered UPS loads, limit x”d to 9 .6% .

For electrical soft starter modules, limit x”d due to the calculated impact kVA to 8% .

For Variable Speed/Frequency Drive motor controls and 6 pulse unfiltered UPS loads, limit x”d to 5 .4% .

In addition, it is advisable to isolate the alternator control system (AVR) from the impact of the distorted wave form by using a PMG .

With the information suggested in points 1-6 above, guidance should be sought from the company regarding alternator sizing for compat-ible equipment operation .

We cannot guarantee compatibility of the SCR control device with any other components of the system, nor do these general recommen-dations guarantee the proper operation of the controller with the alternator .

NOTE: Reactance data is published in our submittal data sheets in Section 6 of our technical CD, or on our website www .stamford-avk .com .

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

NON-LINEAR LOADING

Page 51: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

51

TESTING & CHARGES

• The company is ISO 9000 (9001) certified, requiring all procedures be fully documented and monitored . • Our test procedures meet BSS, IEC, NEMA & IEEE . Tests in accordance to MIL STD 705C can be conducted upon request for a nominal charge .• All Stamford generators are tested to satisfy the routine test requirement of BS EN 60034-1-2004 Values are NOT recorded . A test certificate (TR31) is available upon request, at no charge .• Routine tests on 804 Frames are as follows: LV ES (100+110+120) + ER(100+110+121+131+230+231) + MR110 . MV/HV: In addition to tests specified for LV machines, ES101, Tan Delta, and insulation time constant are included . CUSTOMER SPECIFIED AND WITNESSED TESTS (NET)Set up fees and factory witnessed charges are applicable - in addition to any specific test charges .

Frame P0/P1/S0/S1 UC22/27 S4/HC5 HC6/P7 P80 (LV) MV 7/P80 (MV/HV)

Set Up $155 $300 $495 $745 $1,390 $1,450

Heat Run $785 $1,125 $1,410 $1,835 $2,285 $2,285

Witnessed $1,230 $1,560 $2,185 $2,680 $6,080 $6,820

Witnessed test charges permit up to 3 people attending our factories, per day . The company accepts no liability for customer’s and/or their representatives while in our factories .

TEST CHARGES (NET)NET PRICES

TEST DESCRIPTION TEST REPORT No. S0/S1/P0/P1/UC/HC/PI7/PE7/S4 MV/804

ES100 Insulation Resistance TR19 $100 $160ES101 Polarisation Index TR30 $235 $410ES110 Winding Resistance TR20 $100 $160ES120 High Voltage AC Breakdown TR19 $100 $160ER100 Phase Sequence TR02 $50 $90ER110 Voltage Unbalance TR09 $100 $160ER120 Voltage Regulation TR02/03 $185 $325ER121 Residual Voltage (Self Exciting Machines) TR02/03 $50 $90ER130 Open-Circuit Characteristics OCC TR06 $185 $325ER131 Short-Circuit Characteristics SCC TR06 $280 $490ER132 D-axis Unsaturated Synchronous Reactance Xdu (+ER130 & 131) TR06A $520 $880

ER140 Temperature Rise Test (Heat Run) TR03/05/05A See Above $2,285

ER141 Temperature Rise Characteristics (3x ER 140 per Voltage) TR05B $2,280 $6,365ER150 Sustained Short-circuit Self Excited TR10 $280 $490

ER152 Momentary Overload $445 $980

ER160 Transient Voltage Dip and Recovery Time (1 Dip) TR12 $280 $490ER161 Transient Voltage Rise and Recovery Time TR12 $280 $490ER162 Voltage Dip Characteristics TR12A $745 $1,305ER170 Waveform Analysis . (NL, FL, 0 .8, 1 .0, L-L, L-N) TR07

$2,000 $2,280ER 171 Waveform Distortion Factor (+ER170) TR07EE 172 Telephonic Harmonic Factor (50Hz) (+ER170) TR07ER 173 Telephone Influence Factor (60Hz) (+ER170) TR07ER180 Waveform Graph (+ER170) TR07AER181 Waveform Deviation Factor TR16 $745 $1,305

ER190

Short Circuit Decrement Curve with Separate Excitation **3 Phases Note: This includes the following results for reactances and time constants . ER191 - D-axis Saturated Synchronous Reactance Xd ER192 - D-axis Transient Reactance X’d ER193 - D-axis Subtransient Reactance X’d ER194 - D-axis Transient Short-circuit Time Constant T’d ER195 - D-axis Subtransient Open-circuit Time Constant T'd **Voltage reduced to 50% if performed on customer machines

TR13A TR13 $1,300 $2,280

ER200 D-axis Transient Open Circuit Time Constant Tdo (Only if slip rings fitted) TR13A $185 $330ER210 Negative Sequence Reactance X2 TR14 $280 $490ER220 Zero Sequence Reactance Xo TR15 $280 $490

ER230 No-load Losses TR23 $0 $655

ER231 Full-load Losses (Machine required to be up to temperature) TR24 $630 $1,150ER232 Efficiency (Includes ER230 &231) TR25 $1,085 $1,965MR100 Overspeed (120%) TR08 $50 $90MR110 Vibration TR04 $185 $325MR120 Airflow TR18 $745 $1,305MR130 Noise TR21/22 $490 $1,150

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

Page 52: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

52

RECOMMENDED SERVICE PARTS

DESCRIPTION Prices S0 S1 P0/P1 UC 22/27 HC5 S4D/S4S HC6/7 P7 MV7/P80

PART# PART# PART# PART# PART# PART# PART# PART# PART#

Voltage Regulators (AVR)

AS540 $250 A054P369 A054P369

SX460 $250 — — — E000-24602/1P — — — — —

SX460–UL $250 — — — E000-24608/1P — — — — —

AS480–UL $250 — — E000-14808/1P — — — — — —

SX421 $730 — — — E000-24210/1P

E000-24210/1P — — — —

AS440 $430 — — — E000-24403/1P E000-24403/1PE000-24403/1P — — —

AS440–UL $430 — — — E000-24408/1P E000-24408/1P — — — —

MX341 (PMG Excited) $430 — — — E000-

23412/1PE000-

23412/1PE000-

23412/1P — — —

MX341–UL (PMG Excited) $430 — — — E000-

23408/1PE000-

23408/1P — — — —

MX342 (PMG Excited) $430 — — — E000-

23422/1PE000-

23422/1P — — — —

MX321 (PMG Excited) $600 — — — E000-

23212/1PE000-

23212/1PE000-

23212/1P E000-23212/1P — —

MA330 (PMG Excited) $1,300 — — — — — — — — E000-13300/1P

DM110 (Digital) $1,800 — — — — — — — — E000-23800Other Parts

O & M Manual RTF A055C833 A055C833 P0/P1-OP&INST UCH- 027E 2H-056E A055Z163 2H-056E PE7-MAN RTF

Rectifier Service Kit (RSK) RTF A054H820 A025G494 RSK-1101 RSK-2001 RSK-5001 A025G068 RSK-6001 RSK-6001 RSK-6001

Rotating Rectifier Assembly* RTF A051C308 45-0427 45-0427 45-0428 450-16016 450-16016 450-16025 760-11216 810-1015

Varistor RTF — A025K954 073-08063 073-08059 450-11760/1 A026B171 450-11760/1 450-11760/1 —

RTF: Refer to Factory*COMPRISES: 1 EACH FORWARD PLATE, REVERSE PLATE AND VARISTOR(S) .

PMG KITS *

FRAMEPMG KIT (LESS AVR)

PMG kits contain: rotor, stator, cover, and mounting hardware .Individual component parts are not sold separately .

PART#

UC22/27 45-0075AS4D/S4S 45-0318A

HC5 45-0328AHC6 45-0341A

HC7/P7/MV7 ** 45-0119AP80 RTF

RTF: Refer to Factory

EBS KITS *

FRAMEEBS KIT (LESS AVR)

EBS kits contain: rotor, stator, cover, control module, and mounting hardware . Individual component parts are not sold separately .

PART#

P0/P1-2 pole 45-1212P0/P1-4 pole 45-1210

* Listed EBS/PMG Kits are used on current product, for older product and service replacements please contact the factory with the machine serial number .** For HC7 only, use kit 45-0397A if unit was manufactured between 11/98 and 01/01 - Contact factory representative with machine serial number to determine production date .

Page 53: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

RECOMMENDED SERVICE PARTS

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

53

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

BEARING KITS***

FRAMEDRIVE END NON DRIVE END

PART# PART#

S0 - A054H811

S1 - 45-0866

P0/P1 . . .BC16/18 45-0363 45-0866

UC22 45-0365 45-0867

UC27 45-0367 45-0868

S4D/S4S 45-0319 45-0320

HC5 45-0321 45-0320

HC6 45-0339 45-0340

MV7 45-0335 45-0336

P7 / PM7: 1BRG (A-G) — 45-0421

P7 / PM7: 2BRG (A-E) 45-0335 45-0336

P7 / PM7: 2BRG (F/G) 45-0425 45-0424

P80 804 R,S,T 45-0408 45-0407

P80 804 X,W 45-0409 45-0407

NOTES:For Bearing Kits please Refer to Factory.

***All STAMFORD supplied bearings contain special Kluber Asonic GHY72 (45-0281) synthetic lubricant.

Page 54: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

54

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

SINGLE BEARING ADAPTORS – PART NUMBER & LIST PRICE BY FRAME

ADAP-TORSAE

S0L1 S0L2 S1L2P0/

P144D-G

PI 144H, J&K UC224 UC274 UCDI274 S4D S4S HC5 HC6 MV7 PI7 P80 P80***

6 – – – 45-1194 – – – – – – – – – – – –

5 A053E624 A053F383 – 45-1193 – – – – – – – – – – – –

4 A052V920 A053F381 A053F333 45-1192 45-1192 45-0528 – – – – – – – – – –

3 A053E622 A052V905 A052T358 45-1191 45-1191 45-0527 45-0521 45-0850 – 45-0753 – – – – – –

2 – – – 45-1190 45-1190 45-0526 45-0520 45-0851 – 45-0721 – – – – – –

1 – – – – – 45-0689 45-0690 45-0852 A056B802 45-0665 45-0669 45-0937 – – – –

1 Round

– – – – – – – – – 45-0916 45-0802 – – – – –

1/2 – – – – – – – – A056N655 45-0664 45-0668 45-0944 – – – –

0 – – – – – – – – – 45-0663 45-0667 45-0943 45-0674 45-1011 800-30040 800-11156

00 – – – – – – – – – – 45-0666 45-0942 45-0673 45-1012 800-30038 800-10635

GM – – – 45-1199 45-1199****

N179-5154-01

**** N179-

5154-02 – – – – – – – – –

* Spacer Ring used with SAE 5 (45-0725).*** Two bearing close coupled adaptors.**** Alternator must have a SAE 3 engine adaptor to allow coupling of GM engine adaptor.

COUPLING ASSEMBLIES – PART NUMBER & LIST PRICE BY FRAMECOU-PLING SAE

ADAPTOR SAE

S0L1/ S0L2 S1L2 P0/

P144D-GPI144H,

J&K UC224 UC274 UCDI274 S4S S4D HC5 HC6 MV7 PI7 P80

6 .54/5 A053E721 – 45-1170 – – – – – – – – – – –

6 – – 45-1181 – – – – – – – – – – –

7 .54/5 A052W678 – 45-1171 45-1187 – – – – – – – – – –

6 – – 45-1182 – – – – – – – – – – –

8 4/5 – – 45-1172 45-1177 45-0757 – – – – – – – – –

104 A052W626 A053G584 45-1173 45-1178 45-0758 45-0764 – – – – – – – –

3 A052W626 A053G584 45-1173 45-1178 45-0758 45-0764 – – – – – – – –

11 .5 3 A052W676 A053G582 45-1174 45-1179 45-0759 45-0765 45-0768 45-0776 45-0776 – – – – –

DELCO 15 .5 – – – – 45-0761 – – – – – – – – –

DELCO 17 .75 – – – – – 45-0767 – 45-0779 45-0779 45-0783 – – – –

14 – – – – – 45-0760 45-0766 45-0766 45-0777 45-0777 45-0780 45-0788 – – –

18 – – – – – – – – 45-0778 45-0778 45-0781 45-0789 45-0792 45-0792 800-C01

21 – – – – – – – – – – 45-0782 45-0790 45-0793 45-0793 800-C02

24 – – – – – – – – – – – – 45-0794 45-0794 800-C03

GM – – – 45-1188 45-1189 N179-5164-01

N179-5164-02 – – – – – – – –

ADAPTORS & COUPLINGS

Page 55: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

55

Adaptor Coupling S0 S1 P0/P1 D-G P1 H-K UC22 UC27 UCD27

J-K S4S S4D HC5 HC6 PI7 P80

6 6 .57 .5

5

6 .57 .58

4

6 .57 .5810

3810

11 .5

210

11 .5 15 .5D

1

11 .514

15 .5D17 .75D

1/2

11 .5 1418

17 .75D

01418

17 .75D

00182124

GM GM

Available Most Common Special Build Frames R-S-T only

*P1 H and J, these are the only coupling and adaptor combinations available .

Standard Industrial Flywheel Housings

S.A.E. No. A B C E No. Holes Size

00 31 34-3/4 33-1/2 3-15/16 16 1/2-13

0 25-1/2 28 26-3/4 3-15/16 16 1/2-13

1/2 23 25-1/2 24-3/8 3-15/16 12 1/2-13

1 20-1/8 21-3/4 20-7/8 3-15/16 12 7/16-14

2 17-5/8 19-1/4 18-3/8 3-15/16 12 3/8-16

3 16-1/8 17-3/4 16-7/8 3-15/16 12 3/8-16

4 14-1/4 15-7/8 15 3-15/16 12 3/8-16

5 12-3/8 14 13-1/8 2-13/16 8 3/8-16

6 10-1/2 12-1/8 7-7/8 2-13/16 8 3/8-16

Standard Industrial Flywheels

Nom. Clutch Dia. A B C E AN (G) No. Holes Bolt Size

6-1/2 7-1/4 8-1/2 7-7/8 2-13/16 1-3/16 6 5/16-18

7-1/2 8-1/8 9-1/2 8-3/4 2-13/16 1-3/16 8 5/16-18

8 8-7/8 10-3/8 9-5/8 3-15/16 2-7/16 6 3/8-16

10 10-7/8 12-3/8 11-5/8 3-15/16 2-1/8 8 3/8-16

11-1/2 12-3/8 13-7/8 13-1/8 3-15/16 1-9/16 8 3/8-16

14 16-1/8 18-3/8 17-1/4 3-15/16 1 8 1/2-13

16 18-1/8 20-3/8 19-1/4 3-15/16 5/8 8 1/2-13

18 19-5/8 22-1/2 21-3/8 3-15/16 5/8 6 5/8-11

21 23 26-1/2 25-1/4 3-15/16 0 12 5/8-11

24 25-3/8 28-7/8 27-1/4 3-15/16 0 12 3/4-10Delco Industrial Flywheels

15 .5D — 15-1/2 13-7/8 — 23/32 8 (4x2) 5/8-11

17 .75D — 17-3/4 15-1/2 — 23/32 8 (4x2) 5/8-11

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

SAE ADAPTOR/COUPLING AVAILABLE COMBINATIONSDIMENSIONS

Page 56: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

56

RATING DEFINITIONS All ratings are based on altitude up to 1000 metres above sea level .

BASE CONTINUOUS RATINGAlso known as BASIC CONTINUOUS - BR (ISO 8528-3) or Continuous Running Duty or Continuous Duty . The generator is capable of supporting the specified kVA rating at the specified ambient and power factor for continuous use without overstressing the insulation system .

PEAK STANDBY RATING (40°C ambient temperature)This rating is defined in ISO 8528-3 as PEAK CONTINUOUS–PR . It equates to S10 (rating with discrete constant loads) in EN60034-1 . The class H temperature rise is allowed to increase above the BASE continuous rating . The result is an increased rating at the expense of reducing the operating life of the generator between 2 to 6 times . Peak standby continuous rating offers an economical sizing for emergency backup power supplies .

PEAK STANDBY RATING (27°C ambient temperature)EN 60034-1 states that with the customer’s prior agreement an increase in rating may be made to account for a decrease in ambient tem-perature . The ratings quoted at 27°C ambient allow for an increased temperature rise to bring the operating temperature of the generator to the same level as seen at 40°C ambient as above .

POWER FACTORPower Factor is the ratio of the real power consumed by the load to the apparent power delivered by the generator . Power Factor (PF) = kW / kVA The nature of the load will determine if the current drawn is in phase or out of phase with the voltage generated . The current will either lead or lag the voltage waveform . For normal industrial loads, unless specified otherwise, we assume the power factor to be 0 .8 lagging . This would indicate primarily motor loads . Resistive loads are always 1 .0 PF .

WINDING NUMBERS USED ON STAMFORD AC GENERATORSWindings for STAMFORD AC generators may be selected to give voltages for different connections as follows:

WINDINGNUMBER Leads

60HZ 50HZSERIESSTAR

(3 Phase)

PARALLELSTAR

(3 Phase)

SERIESDELTA

(3 Phase)

DOUBLEDELTA

(1 Phase)

OTHER(1 Phase)

SERIESSTAR

(3 Phase)

PARALLELSTAR

(3 Phase)

SERIESDELTA

(3 Phase)

DOUBLEDELTA

(1 Phase)

OTHER(1 Phase)

05 4 220/110

06/706*** 4 240/120

07** 6 600 346

13** 6 380-416 220-240

14 12 380-416 190-208 220-240

17 12 600 300 346

311/711*** 12 416-480 208-240 240-277 220-240 380-440 190-220 220-254 220-240

312** 6 416-480 240-277 380-440 220-254

51 6 4160 2400

61 6 6300

71* 6 7200 6000

81 6 11,400 10,000

83 6 10,500

83 6 11,000

87 6 12,470

91 6 13,200

91 6 13,800

*For P80 only frames are Star connected only and cannot be reconnected to Delta .

**For Windings 07, 13 and 312, P7 frames are Star connected only and cannot be reconnected to Delta .

***Windings 706 and 711 have auxiliary windings

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

RATING DEFINITIONS WINDING NUMBERS

Page 57: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

57

ALTITUDEUp to 1000m (3300 ft .) no deration in output is required . Above 1000m (3300 ft .) the air becomes less dense and its ability to transfer heat declines . For every 500m (1650 ft .) above 1000m, the output of the machine must be reduced by 3% .

Altitude Deration Factor Altitude Deration Factor

1,500m (4,900 ft .) 3% 0 .97 3,000m (9,900 ft) 12% 0 .88

2,000m (6,600 ft .) 6% 0 .94 3,500m (11,500 ft) 15% 0 .85

2,500m (8,200 ft .) 9% 0 .91 4,000m (13,100 ft .) 18% 0 .82

* For Medium Voltage and High Voltage machines, additional limitations apply . Refer to Application Engineering for specifics .

AMBIENTInsulation materials and systems are rated by their total thermal capacity . We use Class H materials throughout the range of products .

The standards, i .e . NEMA, BSS, IEC, CSA, limit the total temperature as follows:

Class H Temp. Rise Ambient Total

Peak Stand-by 163 °C 27 °C 190 °C

Standby 150 °C 40 °C 190 °C

Continuous 125 °C 40 °C 165 °C

For Ambient temperatures above 40 °C the following derates are required .

Ambient Deration Factor

45 °C (113 °F) 3% 0 .97

50 °C (122 °F) 6% 0 .94

55 °C (131 °F) 9% 0 .91

60 °C (140 °F) 12% 0 .88 CONNECTION DIAGRAMS FOR WINDING 311 MACHINES:Assemblers and users should refer to the wiring and connection diagrams supplied with each machine before operation to ensure the main stator connection complies with the voltage required .

ALTITUDE & AMBIENT DERATION CONNECTION DIAGRAMS

HIGH WYE 3 PHASE 4WOUTPUT: U, V, W AND N

60 HZ 416/240 - 480/277V50 HZ 380/220 - 440/254V

U

N

VW

U1U2U5U6

W6

W5W2

W1

V6V5

V2V1

LOW WYE 3 PHASE 4WOUTPUT: U, V, W AND N

60 HZ 208/120 - 240/139V50 HZ 190/110 - 220/127V

U

N

W

V

U5

U6

U1

U2

W1

W2

W5

W6

V6

V2

V1V5

SERIES DELTA 3 PHASE 3WOUTPUT: U, V, W AND N

U

W

N

V

U1

U2U5

U6

V1V2V6 V560 HZ 240-277V50 HZ 220-254V

W1

W2

W5

W6

DOUBLE DELTA 1 PHASE 3WOUTPUT: U, W AND N

60 HZ 240/120V50 HZ 220/110V

V1

V2V6

V5 W6

W5

W2

W1

U5 U6U1 U2U

NW

L1 L0 L2

PARALLEL DELTA 1 PHASE 2W*OUTPUT: U, V

60 HZ 120V50 HZ 110V

U

W

V

L1 L2

V1V2

V5V6

U1

U2

U5

U6W5

W6

W1

W2

TERMINAL MARKINGS

METRIC NEMA

UVWN

L1L2L3N

U1U2U5U6

V1V2V5V6

W1W2W5W6

T1T4T7T10

T2T5T8T11

T3T6T9T12

*Available with AS480, SX460 & AS440 AVR. For MX341 AVR a 120 to 240V step up transformer is required (not supplied).

Page 58: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

58

MOTOR STARTING CONDITIONSIn order to properly start electric motor loads, the generator must be able to supply the motor kVA inrush at start, with an acceptable drop in voltage . To calculate the start kVA of a motor, multiply the HP rating by the value of kVA per HP as designated by the NEMA code letter found on the motor’s nameplate . See the chart below for the values of the NEMA code letters:

NEMA MG 1-10.37 CODE LETTERS FOR CALCULATING START kVALetter Designation kVA Per Horsepower Letter Designation kVA Per Horsepower

A 0 .0 - 3 .15 K 8 .0 - 9 .0

B 3 .15 - 3 .55 L 9 .0 - 10 .0

C 3 .55 - 4 .0 M 10 .0 - 11 .2

D 4 .0 - 4 .5 N 11 .2 - 12 .5

E 4 .5 - 5 .0 P 12 .5 -14 .0

F 5 .0 - 5 .6 R 14 .0 -16 .0

G 5 .6 - 6 .3 S 16 .0 -18 .0

H 6 .3 - 7 .1 T 18 .0 - 20 .0

J 7 .1 - 8 .0 U 20 .0 - 22 .4

V 22 .4 - & up .

After calculating the start kVA for the electric motor, please refer to the data sheets found on the technical CD or our website to determine the voltage dip that will be produced by the selected generator model . This will apply for an Across-the-Line start only . Note that motors operating with Reduced Voltage Starters, Electronic Soft Starters and Variable Speed Drive motors will require additional calculations in order to correctly select a generator to start and run them . Please consult the factory for assistance . PERMANENT MAGNET GENERATOR (PMG) OPERATIONThe PMG is a separate small generator, mounted on the end of the main generator’s shaft . It provides an isolated power source for an MX or MA series voltage regulator . The use of a PMG provides many advantages, specifically:

• Provides isolation of regulator power from line disturbances . • Provides positive regulator power for fault current support . • Allows for maximum motor starting performance of the generator . • Recommended for all non-linear load conditions . • Provides positive voltage build up . • Lowers conducted & radiated RFI .

• SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

MOTOR STARTING / PMG OPERATION

Page 59: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

59

FRAME VOLTAGE RATIO VADIFF. & PROT. METERING

List Price per setCLASS CLASS

PI/ PM 734P80 LV 804 480

1500/5 15

10P10

1FS5 $6,040

2000/5 15 1FS5 $6,040

2500/5 15 1FS5 $6,040

3000/5 15 1/0 .5/0 .2/FS5 $6,040

3500/5 15 1FS5 $6,040

4000/5 15 1FS5 $6,040

3500/5 15 CLASS 1 $6,040

4500/5 15 CLASS 1 $6,040

5500/5 15 CLASS 1 $6,040

6000/5 15 CLASS 1 $6,040

MV734 P80 MV804 4160

500/5 15

10P10 CLASS 1

$4,870

600/5 15 $4,870

800/5 15 $4,870

P80 Hv804 7200

800/5 15

10P10 CLASS 1

$4,870

200/5 15 $4,870

250/5 15 $4,870

P80 Hv804 11400/13800

300/5 15

10P10 CLASS 1

$4,870

120/5 15 $4,870

150/5 15 $4,870

200/5 15 $4,870

250/5 15 $4,870

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

NOTES:1. Current transformers (CTs) are supplied in sets of 3 and are mounted within the generator terminal box. 2. Matched CTs for mounting in the customers switchgear or panel can be supplied loose, at the prices indicated.

CURRENT TRANSFORMERS – 60 HZ DIFFERENTIAL, PROTECTION & METER-ING

Page 60: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

60 For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

The following freight policy applies to road shipments within the United States, Canada and Mexico, for customers whose accounts are in good standing . Please consult our customer support center at 1 763 528 7301 for deliveries outside of the areas outlined below .

All prices are quoted ex-works Minneapolis, MN . Customer can determine one of the following freight policies: A. Pick up at Minneapolis B. Ship by their designated carrier, with all charges collect . C. Ship by our designated carrier, with charges added per the indicated schedule .

The majority of the shipments follow option C, whereby we prepay and add the freight to the invoice as a courtesy . Title to the goods transfers at our ex-works point (Minneapolis) . This is true for all US shipments . Any claims resulting from damage or loss is the responsibility of the customer with the carrier .

Charges are applied based on zones and are calculated on the net cost of the machine plus any accessories . Freight minimums apply where small low value machines are shipped individually . We will consolidate orders where practical to minimize the number of waybills .

PARTS FREIGHT POLICY:• Minimum charge of $25 .00, or the actual freight rate, whichever is greater .

AIR FREIGHT POLICY:• Customers may airfreight machines from our Minneapolis warehouse or from our Factory Plants at their own discretion . • Such arrangements are the responsibility of the customer and their appointed carrier/ broker .• Pick up can be arranged with our Minneapolis warehouse by calling 1 800 367 2764 . Pick up location is Minneapolis, MN Zip Code 55432 .• All charges associated with such arrangements are the responsibility of the customer alone . Our standard terms are ex-works Minneapolis .

Before operating the generating set, read the generator set operation manual and the generator instruction manual and become familiar with it and the equipment . If one is not available, please contact the supplier .

SAFE AND EFFICIENT OPERATION CAN ONLY BE ACHIEVED IF THE EQUIPMENT IS CORRECTLY OPERATED AND MAINTAINED.Many accidents occur because of failure to follow fundamental rules and precautions .

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH.

• Ensure installation meets all applicable safety and local electrical codes . Have all installations performed by a qualified electrician .• Do not operate the generator with protective covers, access covers or terminal box covers removed .• Disable engine starting circuits before carrying out maintenance .• Disable closing circuits and/or place warning notices on any circuit breakers normally used for connection to the mains or other gen-

erators, to avoid accidental closure .

Observe all IMPORTANT, CAUTION, WARNING, and DANGER notices, defined as:

Important ! Important refers to hazard or unsafe method or practice which can result in product damage or related equipment damage.

SAFETY PRECAUTIONS

Caution !Caution refers to hazard or unsafe method or practice which can result in product damage or personal injury .

Warning !

Warning refers to a hazard or unsafe method or practice which CAN result in severe personal injury or possible death .

Danger !

Danger refers to immediate hazards which WILL result in severe personal injury or death .

ZONE DESCRIPTIONZone State/ Province

1 Continental USA

2 Canadian Provinces

3 Hawaii, Alaska,Puerto Rico, The Caribbean, and Mexico (quotes upon request)*

ZONE MINIMUM FREIGHT %1 $100 6 .00%

2 $100 7 .00%

3 * *

• PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE .

FREIGHT POLICY

Page 61: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

61

1 DELIVERY AND RETURNS. All orders are subject to acceptance by Seller, in its sole discretion, at its general office, even if received elsewhere by a Seller’s Employee, selling agent, or other representative . Buyer can not cancel orders, nor can delivery of goods made up or in process be deferred or extended beyond the original delivery date, except with Seller’s consent and upon terms which will indemnify it against loss . Buyer may return goods only after receiving written approval from Seller . Buyer will pay return transportation charges . All returns and/or cancellations will be subject to a restock fee of 25% .

2 TECHNICAL ADVICE. Seller assumes no liability for any technical advice, or results obtained there from, all such advice being given and accepted at Buyer’s risk . Buyer will apply goods in accordance with applicable regulations, codes, industry standards and Seller’s recommendations, and will defend, indemnify, and hold Seller harmless from all claims, damages and causes of action arising out of its failure to do so . Buyer shall assure that the original purchaser of goods for use receives all Sellers’ manuals, instructions, warnings, printed Limited Warranty, and other literature accompanying or associated with the goods .

3 WARRANTY, LIMITATION OF LIABILITY AND NOTICE OF CLAIMS.

A. WARRANTY. Seller extends to the original purchaser of goods for use, Seller’s current Limited Warranty, a copy of which has been provided to Buyer and a copy of which will accompany the product . THERE IS NO OTHER EXPRESS WARRANTY TO BUYER, OEM OR ORIGINAL PURCHASER OF GOODS FOR USE . TO THE EXTENT PERMITTED BY LAW, ANY AND ALL IMPLIED WARRANTIES INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED . IF NOT EXCLUDED BY REASON OF LAW, IMPLIED WARRANTIES ARE LIMITED TO THE EXPRESS WARRANTY PERIOD .

B. LIMITATION OF LIABILITY. Seller’s sole liability and the sole remedy available under the printed Limited Warranty or any implied warranty not excluded 3A above, for failure of goods to perform as warranted shall be limited to the repair or replacement of goods returned to Seller’s factory, or to Seller’s Authorized Distributor or its designated service representative, transportation prepaid .

C. NOTICE OF CLAIM. All claims must be brought to the attention of Seller or an Authorized Distributor or its designated service representative within thirty (30) days after discovery of breach of warranty . No person will be authorized to give any other warranties or to assume other liabilities on Seller’s behalf, unless expressly made in writing by Seller .

4 PRODUCT CHANGES. Seller reserves the right to change specifications and/or designs without obligation to Buyer . Seller shall revise the purchase price to cover any increased cost arising from changes Buyer requests .

5 FORCE MAJEURE. Deliveries may be cancelled or delayed by either party without liability in case of an Act of Nature, war, riots, fire, explosion, flood, accident, machinery malfunction, acts of local, state or national government, or inability to obtain fuel, power, raw materials, labor or transportation, or any similar cause beyond the control of such party, which prevents the manufacture, shipment, acceptance or consumption of a shipment of the goods or of a material upon which the manufacturer of the goods is dependent . If, because of any such circumstances, Seller is unable to supply the total demand for the goods, Seller may allocate its available supply among itself and all of its customers, including those not under contract . Seller shall not be liable to Buyer under this contract for any damages or expenses caused by such circumstances .

6 WAIVER. No waiver or failure to assent any right or remedy, and no course of dealing shall be deemed to constitute a waiver of any other breach or default of any other right or remedy, unless such waiver is expressed in writing and signed by the party to be bound .

7 ASSIGNMENT. Buyer may not assign this contract or the obligations hereunder without Seller’s prior written consent .

8 SET OFFS. Seller may set off against any amounts which may become payable by Seller to Buyer hereunder or otherwise, any amounts which Buyer may owe Seller, whether arising hereunder or otherwise .

9 BUYER’S CREDIT. Seller reserves the right among other remedies, either to terminate or suspend deliveries hereunder in the event Buyer fails to pay for any one shipment when payment becomes due . Should Buyer’s financial responsibility or capability become unsatisfactory to Seller, Seller may require cash payments or satisfactory security for future deliveries and for goods therefore delivered . Seller reserves the right to request and review Buyer’s financial information to establish credit terms and limits from time to time . Such terms and limits may be changed at Seller’s discretion with or without notice to Buyer .

10 TITLE AND RISK OF LOSS. Title and Risk of Loss shall pass to Buyer on delivery of goods to a carrier selected by Seller . Buyer shall accept and inspect all shipments immediately upon arrival and shall file claims with or against the carrier for any losses, shortages or damages of any kind .

11 PAYMENT. If payment is not made when due, the Seller may charge the Buyer interest at the lesser of the highest legal rate or the rate charged pursuant to Seller’s then-currency policy . Unless otherwise expressly set out on the face hereof, Buyer shall pay the purchase price for all goods shipped net within thirty (30) days after delivery . No discounts may be taken except in accordance with Seller’s then-currency written policy, if any . In the case of international orders, (i) Buyer shall pay the full purchase price for all goods shipped immediately upon delivery; or (ii) if previously agreed to by Seller in writing, contemporaneously with order placement, Buyer shall establish in Seller’s favor an irrevocable letter of credit issued or confirmed by a United States bank acceptable to the Seller, in an amount sufficient to cover the price of the goods and all related expenses which are for the Buyer’s account but are initially incurred by Seller, and including such other terms and conditions as are acceptable to Seller, and shall permit ship-ment to be made by Seller from any United States port . Any and all bank financing charges, taxes or other expenses related to such letters of credit are for the Buyer’s account; or (iii) with prior written approval of Seller’s Credit Department, other payment terms may be arranged for payment at a predetermined number of days from either invoice date or date of delivery to a carrier of our choice by either open account, or other commercial debts instruments of international trade .

12 COMPLIANCE WITH LAW. Seller complies with all applicable laws, including the requirements of the Fair Labor Standards Act of 1938, as amend-ed, Executive Order 11246, the Rehabilitation Act of 1973, the Vietnam Era Veterans Readjustment Act of 1974 and Executive Order 11625 and the rules, regulations and relevant orders promulgated hereunder if applicable .

13 APPLICABLE LAW, ENTIRE AGREEMENT. This contract is to be construed according to the laws of the State of Minnesota, and not the U .N .C .I .S .G . All disputes arising here from which the parties cannot amiably resolve shall be litigated in the State of Minnesota, and Buyer hereby submits to the jurisdiction of such courts . Any action for breach must be commenced within one (1) year after the cause of action has occurred . This document, including those regulations specifically incorporated by reference, constitutes the full understanding of the parties and no terms, condi-tions, understanding or agreement purporting to modify or vary the terms of this document shall be binding unless hereafter made in writing and signed by the party to be bound . Notwithstanding any different or additional terms or conditions that may be embodied in any purchase order or other documents submitted by Buyer, which terms and conditions are hereby objected to, Seller accepts the order described on the face hereof on the express condition that Buyer assents to these terms and conditions, and Buyer’s acceptance of the initial delivery of goods shipped hereunder shall constitute assent to all such terms and conditions .

14 TAXES AND IMPORT CHARGES. Any tax or governmental charge or increase in same hereafter becoming effective increasing the cost to a Seller of producing, selling or delivering the goods or of procuring material used therein, and any tax now in effect or increase in same payable by Seller because of the sale of goods, such as Sales Tax, Use Tax, Retailer Occupational Tax, Turnover Tax, Value Added Tax, customs duties, consular fees, may, at Seller’s option, be added to the price specified in this Contract . Buyer shall be responsible for obtaining clearance of the goods through customs .

15 INSURANCE AND FREIGHT CHARGES. Unless otherwise agreed to in writing, Seller may, but shall not be obligated to obtain insurance to the Buyer’s warehouse or other designated point of destination against all risks “American Institute Cargo Clauses” or equivalent with a strike, riots, and civil commotions endorsement, and against war risks if obtainable . All such insurance charges are for the Buyer’s account . Freight and insur-ance charges are merely estimates based on currently prevailing rates . As these charges are beyond the control of Seller, any variations existing at the time of shipments are for the account of Buyer .

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

TERMS AND CONDITIONS

Page 62: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Headquarters

Manufacturing Plants

Regional Offi ces

Distribution Centres

Headquarters

Manufacturing Plants

Regional Offi ces

Distribution Centres

*Multiple Entities

MinneapolisToronto

San Luis Potosi

New Orleans

Miami

Peterborough

Madrid

Moscow

StamfordOslo

Milan

Beirut

Dubai

Craiova

Pune

Ahmednagar

Ranjangaon

Johannesburg

Singapore

Tokyo

Adelaide

Wuxi Xin Rong

Wuxi Xiang JiangDenver

Locations

UKCummins Generator TechnologiesFountain CourtLynch WoodPeterborough, PE2 6FZTel: +44 (0) 1733 395300Fax: +44 (0) 1733 [email protected]

■Barnack RoadStamfordLincolnshire, PE9 2NBTel: +44 (0) 1780 484000Fax: +44 (0) 1780 [email protected]

AUSTRALIA •Cummins Generator Technologies Australia50-52 Diagonal Road Pooraka, South Australia, 5095Tel: +618 8368 4344Fax: +618 8260 [email protected]

CANADA •Cummins Generator Technologies Canada2275 Lakeshore Blvd. WestEtobicokeOntario, M8V 3Y3Tel: +1 416 259 3741Fax: +1 416 259 [email protected]

CHINA ■Cummins Generator Technologies ChinaNo. 2 Xin Rong RoadNew DistrictWuxi Jiangsu 214028Tel: +86 510 8110 8088Fax: +86 510 [email protected]

■No. 11 Xiang Jiang RoadHigh-Technical Industrial Dev. ZoneWuxi Jiangsu 214028Tel: +86 510 8110 3088 Fax: +86 510 8521 [email protected]

INDIA •Cummins Generator Technologies India Pvt. LtdCummins India Office Campus, Tower A,6th Floor, Survey No. 21,Balewadi, Pune- 411045,Maharashtra, IndiaTel.: +91 20 6706 7000, 39651000Fax: +91 20 6706 [email protected]

■C-33, M.I.D.C. Ahmednagar 414 111Tel.: +91 (0) 241 6603464 - 73Fax: +91 (0) 241 2777494

■G-06, M.I.D.C. Ranjangaon GanapatiTaluk Shirur, Dist. Pune 412 220Tel.: +91 (0) 2138 399000Fax: +91 (0) 2138 399098

ITALY •Cummins Generator Technologies Italia s.r.l. Via Giosuè Carducci 125Sesto San GiovanniMilano – 20099Tel: +39 02 380 00714Fax: +39 02 380 [email protected]

JAPAN ■Cummins Generator Technologies Japan New Pier Takeshiba South Tower Bldg.15F16-1, Kaigan 1-Chome, Minato-KuTokyo 105-0022, JapanTel: +81 (0) 3 6631 [email protected]

LEBANON •Cummins Generator Technologies LebanonZouk Mosbeh, main Highway,Building Christ le Roi, 7th FloorLebanonTel: +961 922 0759 [email protected]

MEXICO •Cummins Generator Technologies MexicoAv. Circuito Mexico No. 185Parque Industrial 3 NacionesSan Luis Potosi, SLPC.P. 78395Tel: +52 444 870 4400Fax: +52 444 870 [email protected]

NORWAY •Cummins Generator Technologies NorwayOsloveien 201430 ÅsTel: +47 64 97 45 40Fax: +47 64 97 45 [email protected]

ROMANIA ■Cummins Generator Technologies RomaniaB-dul Decebal Nr. 116A200746 Craiova DoljTel: +40 351 443202Fax: +40 351 [email protected]

RUSSIA •Cummins Generator Technologies RussiaPark Place, Office B 200, 113/1 Leninskiy Prospect, 117198 Moscow Tel: +7 495 956 5122 ext. 84 Fax: +7 495 956 [email protected]

SINGAPORE ■Cummins Generator Technologies Singapore10 Toh Guan Road #05-04Singapore 608 838Tel: +65 6305 3150Fax: +65 6305 3151/[email protected]

SOUTH AFRICA •Cummins South Africa (Pty) LtdBuilding 8, Harrowdene Office Park Western Service Road, WoodmeadPrivate Bag X7, Wendywood 2144 Tel: +27 11 589 8517Fax: +27 11 589 [email protected]

SPAIN ■Cummins Spain S.L.Av. del Sistema Solar27. Naves -1-2San Fernando de Henares28830 MadridTel: +34 91 678 76 00Fax: +34 91 678 76 [email protected]

UAE ■Cummins Middle East FZEJebel Ali Free ZoneP.O. Box 17636Dubai, U.A.E.Tel: +9714 [email protected]

USA ■Cummins Generator Technologies USA1400 73rd Ave N.E.Fridley, MN 55432Tel: +1 (763) 528-7301Fax: +1 (763) [email protected]

•Denver, CO Tel: +1 (720) 576-6842

•Miami, FL Tel: +1 (954) 290-4416

•New Orleans, LA Tel: +1 (985) 206-5227

USA_PricingGuide2018_2COL_Pages.indd 5 03/11/2017 08:38

Page 63: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

NOTES:

Page 64: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

NOTES:

Page 65: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

NOTES:

Page 66: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

For customer support contact: 1-800-367-2764/1-763-528-7301 Fax: 1-800-863-9243/1-763-574-5082www.stamford-avk.com

NOTES:

Page 67: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

World-Leading Safety in High Voltage Prime Power AlternatorsEver since the Cutting Brothers established their electrical engineering business in Stamford, UK in 1904

and Arthur van Kaick founded the AvK business in Frankfurt, Germany in 1919, the STAMFORD and AvK

brands have built up powerful reputations for electrical machine manufacturing excellence.

Through the many years that followed and with unwavering dedication to collaborating with customers,

today we are able to boast a proven history of delivering success for our

customers across a variety of high voltage prime power applications.

Building on that legacy, our recent investment into the Craiova site ensures

we are able to continue to focus on enhancing our high voltage product range

from a recognised Cummins centre-of-excellence.

In the latest step of our journey, as well as achieving CSA compliance we

have become the world’s first alternator manufacturer to achieve UL safety

certification for low, medium and high voltages – meaning high voltage

UL approved alternators are now available for our customers across the

STAMFORD | AvK ranges.

Image courtesy of B

roadcrown Ltd H

ixon

USA_PricingGuide2018_Cover_CMYK.indd 3 17/01/2018 10:46

Page 68: Americas Product Selection and Pricing 2018...NEW PRODUCTS • PRICES AND SPECS . SUBJECT TO CHANGE WITHOUT NOTICE NOTES: 1. All S0 & S1 units have Gel Coat as standard 2. For UL1004

Southern Regional ManagerTim TalbotNew Orleans, LAPhone: +1 (985) 875-1280 Cell: +1 (504) 250-7106 Email: [email protected], AR, FL, GA, KY, LA, MS, NC, OK,SC, TN, TX & THE CARIBBEAN

Midwestern Regional ManagerMike Morris1400 73rd Ave NEFridley, MN 55432Cell: +1 (612) 505-8837Email: [email protected], IL, IN, KS, MI, MN, MO,ND NE,OH, SD, WI

Western Regional ManagerCharles SalottiDenver, COPhone: +1 (720) 531-2133Cell: +1 (720) 576-6842Email: [email protected], AZ, CA, CO, HI, ID, MT, NM, NV, OR,UT, WA, WY

Canadian Regional ManagerAntonio Scenna2275 Lake Shore Boulevard West, Suite 522Etobicoke, Ontario M8V 3Y3CanadaPhone: +1 (416) 259-3741Fax: +1 (416) 259-7167Cell: +1 (416) 230-1460Toll Free Phone: 800-565-0045Toll Free Fax: 877-211-7289Email: [email protected], CT, DE, MA, ME, MB, MD, NB, NH, NJ, NL, NS, NU, NY, ON, PA, PE, RI, QC, VA, VT, WV

Distributor - CanadaAinsworth Electric4003 76th AvenueEdmonton, Alberta T6B 2S8Phone: +1 (780) 463-1305Fax: +1 (780) 466-4080Email: [email protected], SK, NT, YT

Mexico & Central America Regional OfficeClaudio JimenezPhone: +52 (444) 870-6713Cell: +52 1 (444) 413-9772Email: [email protected]

Latin America Sales ManagerSergio CardenasMiramar, FLPhone: +1 (954) 378-7311Mobile: +1 (954) [email protected]

Sales Director - North America Ryan Loso1400 73rd Ave NEFridley, MN 55432Phone: +1 (651) 787-7121Cell: +1 (763) 229-3963Email: [email protected]

Inside Sales Representative - North AmericaShwetha PanneerselvamFridley, MN 55432Phone: +1 (954) 378-7311Cell: +1 (612) 402-5624Email: [email protected]

AvK Sales ManagerMike Ostendorf1400 73rd Ave NEFridley, MN 55432Phone: +1 (651) 787-7133Cell: +1 (612) 430-5849Email: [email protected]

AvK Technical Inside Sales Lindsay NelsonFridley, MN 55432Phone: +1 (651) 787-7065Email: [email protected]

Order Management CustomerService ManagerLan Le 1400 73rd Ave NE Fridley, MN 55432 Phone: +1 (800) 367-2764 (Option 2) Fax: +1 (651) 415-5287 Email: [email protected]

Service Engineering ManagerJeff Kocovsky 1400 73rd Ave NE Fridley, MN 55432 Phone: +1 (800) 367-2764 (Option 3) Email: [email protected]

Application Engineering Manager Brian Terrell 1400 73rd Ave NE Fridley, MN 55432 Phone: +1 (651) 787-6142 Fax: +1 (651) 415-5287 Email: [email protected]

Americas Headquarters • Cummins Generator Technologies • 1400 73rd Avenue N. E. • Attn: Mail stop OC200 • Fridley • MN • 55432 • USAToll Free Phone: +1 (800) 367-2764 • Toll Free Fax: +1 (800) 863-9243 • Phone: +1 (763) 528-7301 • Fax: +1 (763) 574-5082

Copyright 2016, Cummins Generator Technologies Ltd, All Rights Reserved STAMFORD and AvK are registered trade marks ofCummins Generator Technologies Ltd. Cummins and the Cummins logo are registered trademarks of Cummins Inc.

A

C

E

D

B

G

F

A

BC

C

DD E

D

G

FA

Customer Support Directory

North AmericaPhone: +1 (800) 367-2764 (toll free)Option 2 (Sales Support)Option 3 (Technical, Parts & Warranty Support)

Sales Support Email:[email protected] & Parts Support Email:[email protected] Support Email:[email protected]

Mexico & Central AmericaPhone: +52 (444) 8704586 (Customer Support)Phone: +52 (444) 8706781 (Technical Support)Toll free USA: +1 (800) 367-2764Option 1 (Spanish)

South AmericaPhone: +52 (444) 8704586 (Customer Support)Phone: +55.11.2186-4684 (Technical Support)

USA_PricingGuide2018_Cover_CMYK.indd 5 12/02/2018 16:00