Freedom 90AUX2B060A9362A, AUX2B080A9422A,AUX2C100A9482A, AUX2D120A9602A,ADX2B060A9362A, ADX2B080A9422A,ADX2C100A9482A, ADX2D120A9602ADirect Vent withVariable Speed Inducer
PUB. NO. 12-1262-02
Upflow/ Horizontal Left,Downflow/ Horizontal RightTwo Stage CondensingGas-Fired Furnace
2 Pub. No. 12-1262-02
GeneralFeatures
© 2009 American Standard Heating & Air Conditioning
NATURAL GAS MODELSCentral Heating furnace designs arecertified by the American Gas Associa-tion for both natural and L.P. gas. Limitsetting and rating data were estab-lished and approved under standardrating conditions using American Na-tional Standards Institute standards.
SAFE OPERATIONThe Integrated System Control hassolid state devices, which continuouslymonitor for presence of flame, whenthe system is in the heating mode ofoperation. Dual solenoid combinationgas valve and regulator provide extrasafety.
QUICK HEATINGDurable, cycle tested, heavy gaugealuminized steel heat exchangerquickly transfers heat to provide warmconditioned air to the structure. Lowenergy power vent blower, to in-crease efficiency and provide apositive discharge of gas fumes to theoutside.
BURNERSMultiport Inshot burners will give yearsof quiet and efficient service. All mod-els can be converted to L.P. gaswithout changing burners.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnacelimit sensors, blowers, gas valve,flame control and includes self diag-nostics for ease of service. Alsocontains connection points for E.A.C./Humidifier.
AIR DELIVERYThe four speed, direct drive blower mo-tor, has sufficient airflow for mostheating and cooling requirements, willswitch from heating to cooling speedson demand from room thermostat. Theblower door safety switch will preventor terminate furnace operation whenthe blower door is removed.
STYLINGHeavy gauge steel and “wrap-around” cabinet construction isused in the cabinet with baked-onenamel finish for strength and beauty.The heat exchanger section of the cab-inet is completely lined with foil facedfiberglass insulation. This results inquiet and efficient operation due to theexcellent acoustical and insulatingqualities of fiberglass. Built-in bottompan and alternate bottom, left or rightside return air connection provision.
FEATURES AND GENERALOPERATIONThe Freedom90 High Efficiency GasFurnaces employ an Adaptive Heat UpSilicon Nitride Hot Surface Ignition sys-tem, which eliminates the waste of aconstant burning pilot. The integratedsystem control lights the main burnersupon a demand for heat from the roomthermostat. Complete front serviceaccess.a. Low energy power venterb. Vent proving pressure switch.
3Pub. No. 12-1262-02
Contents
General FeaturesFeatures and Benefits
Standard Equipment
Optional Equipment
General Data
AUX2B060A9362AAUX2B080A9422AAUX2C100A9482AAUX2D120A9602AADX2B060A9362AADX2B080A9422AADX2C100A9482AADX2D120A9602A
Performance Data
Venting Tables
Electrical Data
Field Wiring
Twinning Field Wiring
Dimensions
2445
6-7
8-9 10-11
12-13
14-15
16-17
18-19
4 Pub. No. 12-1262-02
FREEDOM 90 STANDARD EQUIPMENT
Featuresand Benefits
• Perfect fit door latches*• Insulated blower door*• Gasketed blower door*• Internal filter rack*• Standard filter sizes• Two tone color• Multi-port In-shot burners• Complete front service access• Left/right gas connection• Adjustable fan off times• Optional L.P conversion kit• Selectable cooling fan off delay elimi-
nates need for BAY24X045time delay kit
• Direct Drive - 4 speed PSC Motor• Silicon Nitride Igniter with adaptive heat
up• Variable speed induced draft blower• Direct/Non-Direct vent option• Fused 24 volt control circuit• Manual reset burner safety switches• Power supply 115/1/60• Convertible to horizontal on left side• 2-stage gas valve• PVC venting-1 or 2 pipe option• Accessory hook-up capability• Integrated solid state control with
self-diagnostics• Attractive color accents• Heavy gauge aluminized steel heat
exchanger• Multi-port In-shot burners• Single wire twinning• HInged blower door *
* (Upflow only)
5Pub. No. 12-1262-02
Featuresand Benefits
FREEDOM 90 OPTIONAL EQUIPMENT
Thermostat, 2-Stage Heat / 1-Stage Cooling ............................................................................................... TAYSTAT241 [ ]Thermostat, Electronic Programmable 2-Stage Heating ............................................................................TAYSTAT302C [ ]Thermostat, Mechanical Heating Only With Fan Switch ............................................................................TAYSTAT303C [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ....................................................................AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................... BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ..................................................TAYSTAT300C [ ]Propane Conversion Kit ........................................................................................................................... BAYLPKT210A [ ]5" Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................... TFM145A9FR0 [ ]5" Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................... TFM175A9FR0 [ ]5" Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................ TFM210A9FR0 [ ]5" Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................... TFM245A9FR0 [ ]1" Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) .................................... TFP145A9FR0 [ ]1" Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .................................... TFP175A9FR0 [ ]1" Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................... TFP210A9FR0 [ ]1" Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .................................... TFP245A9FR0 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ..............................................................................................BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ..............................................................................................BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ....................................................................................................BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ..............................................................................................BAYCLE24A2430A [ ]Downflow Subbase .....................................................................................................................................BAYBASE205 [ ]Side Filter Rack ........................................................................................................................................... BAYFLTR200 [ ]Filter Kit/Horizontal Conversion TUX060,080-R........................................................................................... BAYFLTR203 [ ]Filter Kit/Horizontal Conversion TUX100-R ................................................................................................. BAYFLTR204 [ ]Filter Kit/Horizontal Conversion TUX120-R ................................................................................................. BAYFLTR205 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR317 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR321 [ ]Filter Accessory Kit .................................................................................................................................... BAYFLTR324 [ ]High Altitude Pressure Switch Kit ........................................................................................................... BAYHALT2451 [ ]High Altitude Pressure Switch Kit ........................................................................................................... BAYHALT2461 [ ]High Altitude Pressure Switch Kit ........................................................................................................... BAYHALT2471 [ ]Concentric Vent Kit TUX Furnaces ......................................................................................................... BAYVENT100A [ ]Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces ............................................................... BAYVENT200B [ ]Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces .......................................................... BAYMFGH100A [ ]Filter Rack Kit ......................................................................................................................................... BAYRACK960A [ ]Cleanable Filter (14.5"/17.5" wide Upflow models) ...................................................................................... BAYFLTR317 [ ]Cleanable Filter (21" wide Upflow models) .................................................................................................. BAYFLTR321 [ ]Cleanable Filter (24.5" wide Upflow models) ............................................................................................... BAYFLTR324 [ ]1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
6 Pub. No. 12-1262-02
GeneralData
1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODEL
RATINGS21st Stage Input BTUH
1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)3AFUE (ICS)Temp. Rise (Min.-Max.) °F.
BLOWER DRIVEDia.-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/Hz
COMBUSTION FAN - TYPEDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzFL Amps
FILTER — Furnished?Type RecommendedFilter (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
DIRECT IGNITION DEVICEType
BURNERS — TypeNumber
POWER CONN. — V/Ph/Hz4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONSCrated (In.)Uncrated
WEIGHTShipping (Lbs.)/Net (Lbs.)
AUX2 PRODUCT SPECIFICATIONS1
AUX2B060A9362A
3900036000600005600093.0
30 - 60DIRECT10 x 7
14
SEE FAN PERF. TABLE1/3
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY1 - 17 X 25 - 1 IN
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 453 - 56
REDUNDANT - TWO STAGE
HOT SURFACEIN-SHOT
3115/1/60
8.7151/2
SEE OUTLINE DRAWINGH X W X D
41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING
158 / 146
AUX2B080A9422A
5200048000800007300092.5
35 - 65DIRECT10 x 8
14
SEE FAN PERF. TABLE1/3
1075115/1/60
CENTRIFUGALDIRECT - 1
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY1 - 17 X 25 - 1 IN
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 454 - 56
REDUNDANT - TWO STAGE
HOT SURFACEIN-SHOT
4115/1/60
9.5151/2
SEE OUTLINE DRAWINGH X W X D
41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING
168 / 156
AUX2C100A9482A
6500060000
1000009300093.0
35 - 65DIRECT10 x 10
14
SEE FAN PERF. TABLE1/2
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY1 - 20 X 25 - 1 IN
2 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 455 - 56
REDUNDANT - SINGLE STAGE
HOT SURFACEIN-SHOT
5115/1/60
13.1201/2
SEE OUTLINE DRAWINGH X W X D
41-3/4 X 23 X 30-1/2SEE OUTLINE DRAWING
197 / 185
AUX2D120A9602A
7200066600
120000112000
92.540 - 70DIRECT11 x 10
14
SEE FAN PERF. TABLE3/4
1100115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY1 - 24 X 25 - 1 IN
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 456 - 56
REDUNDANT - SINGLE STAGE
HOT SURFACEIN-SHOT
6115/1/60
13.5201/2
SEE OUTLINE DRAWINGH X W X D
41-3/4 X 26-1/2 X 30-1/2SEE OUTLINE DRAWING
206 / 193
7Pub. No. 12-1262-02
MODEL
RATINGS21st Stage Input BTUH
1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS)3AFUE (ICS)Temp. Rise (Min.-Max.) °F.
BLOWER DRIVEDia.-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/Hz
COMBUSTION FAN - TYPEDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzFL Amps
FILTER — Furnished?Type RecommendedFilter (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
DIRECT IGNITION DEVICEType
BURNERS — TypeNumber
POWER CONN. — V/Ph/Hz4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONSCrated (In.)Uncrated
WEIGHTShipping (Lbs.)/Net (Lbs.)
GeneralData
ADX2 PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
ADX2B080A9422AADX2B080A9422AADX2B080A9422AADX2B080A9422AADX2B080A9422A
5200048000800007400092.5
40 - 70DIRECT11 x 8
14
SEE FAN PERF. TABLE1/2
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY2 - 14 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
4 - 454 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITERIN-SHOT
4115/1/60
11.315
0.50SEE OUTLINE DRAWING
H X W X D41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING
168 / 158
ADX2B060A9362AADX2B060A9362AADX2B060A9362AADX2B060A9362AADX2B060A9362A
3900036000600005500092.0
35 - 65DIRECT10 x 8
14
SEE FAN PERF. TABLE1/3
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY2 - 14 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
3 - 453 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITERIN-SHOT
3115/1/60
9.515
0.50SEE OUTLINE DRAWING
H X W X D41-3/4 X 19-1/2 X 30-1/2SEE OUTLINE DRAWING
160 / 145
ADX2C100A9482AADX2C100A9482AADX2C100A9482AADX2C100A9482AADX2C100A9482A
6500060000
1000009300093.0
45 - 75DIRECT11 x 10
14
SEE FAN PERF. TABLE1/2
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY2 - 16 X 20 X 1
2 ROUND
ALUMINIZED STEEL TYPE 1
20
5 - 455 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITERIN-SHOT
5115/1/60
13.120
0.50SEE OUTLINE DRAWING
H X W X D41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
185 / 175
ADX2D120A9602AADX2D120A9602AADX2D120A9602AADX2D120A9602AADX2D120A9602A
7800072000
120000111000
92.545 - 75DIRECT11 x 10
14
SEE FAN PERF. TABLE3/4
1075115/1/60
CENTRIFUGALDIRECT - VARIABLE
1/15 - 500033 - 110/3/60 - 180
1.0NO
HIGH VELOCITY2 - 16 X 20 X 1
3 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 456 - 56
REDUNDANT - TWO STAGE
HOT SURFACE IGNITERIN-SHOT
6115/1/60
13.520
0.50SEE OUTLINE DRAWING
H X W X D41-3/4 X 26-1/2 X 30-1/2SEE OUTLINE DRAWING
206 / 196
8 Pub. No. 12-1262-02
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
*UX2B060A9362A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
139412501102957
135912321092944
131412021069922
126011601034891
11961106986853
11221040925806
1038962852750
945873766686
853771668614
*UX2B080A9422A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
174813751178859
168313671167863
161513471147856
154413141119839
147012681082811
139312101036772
13141139982723
12321056919663
1147960847592
*UX2C100A9482A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2054193217621558
1980187517201546
1906181816771533
1826174616151477
1746167315521421
1649157714631350
1551148113731278
1428137112661175
1305126011581071
*UX2D120A9602A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2454210517471445
2406209217421447
2358207817361449
2310204517201440
2261201217031430
2184195016771400
2106188716511369
2017182615931325
1928176515351280
* - First letter may be "A" or "T"
NOTE: See page 11 for factory heat & cool speed tap settings
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200
*UX2B060A9362A 56 50 45 42 39 36
*UX2B080A9422A 61 56 51 48 44 42
*UX2C100A9482A 64 60 56 52 49 46 44 42
*UX2D120A9602A 63 59 56 53 50 48 46
* - First letter may be "A" or "T"
UpflowPerformance Data
9Pub. No. 12-1262-02
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
*DX2B060A9362A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
148713421181877
142512911147863
136212401113849
128611821061820
120911241009791
11251047943739
1040989877686
935869779612
830769681537
*DX2B080A9422A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1547148713881263
1498143613481234
1445138213021196
1386132512491150
1323126511911095
1254120211261032
118011371056960
11011069979879
1016998896790
*DX2C100A9482A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1892177916301444
1827172615871416
1762167215441388
1688160514851348
1614153814261308
1531146013621246
1448138112971184
1354129112081108
1260120011191032
*DX2D120A9602A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2213205717651468
2138200017331452
2062194317001435
2001188316521409
1939182216031382
1863175215521336
1786168115001290
1706159514241225
1625150813471159
*- First letter may be "A" or "T"
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
*DX2B060A9362A 63 56 51 46 42 39 36 34
*DX2B080A9422A 68 61 56 52 48 45 42 40
*DX2C100A9482A 65 60 56 53 50 47 44 42 40 38 37 35
*DX2D120A9602A 67 63 59 56 53 51 48 46 44 42
*- First letter may be "A" or "T"
DownflowPerformance Data
10 Pub. No. 12-1262-02
Maximum VentLength Table
VENT LENGTH TABLE
ALTITUDEMAXIMUM TOTAL EQUIVALENT LENGTH IN FEET
FOR VENT AND INLET AIR (SEE NOTES)
0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH* PIPE
*UX/ *DX2B060A9362A 200 200 200
*UX/ *DX2B080A9422A 50 120 200
*UX/ *DX2C100A9482A Not Allowed 60 200
*UX/ *DX2D120A9602A Not Allowed Not Allowed 200
7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE
*UX/ *DX2B060A9362A 100 100 100
*UX/ *DX2B080A9422A 25 60 100
*UX/ *DX2C100A9482A Not Allowed 30 100
*UX/ *DX2D120A9602A Not Allowed Not Allowed 100
9,500-12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE
*UX/ *DX2B060A9362A 50 50 50
*UX/ *DX2B080A9422A Not Allowed 30 50
*UX/ *DX2C100A9482A Not Allowed Not Allowed 50
*UX/ *DX2D120A9602A Not Allowed Not Allowed 50
NOTES: * - First letter may be "A" or "T"1. Minimum vent length for all models: 3' horizontal and vertical.2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Exceptadapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to themaximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a largerdiameter, but never smaller than the vent pipe.3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT ISTHE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).4. One SHORT radius 90° elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe.One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kitis used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet.6. Pipe adapters are field supplied (except 120).
11Pub. No. 12-1262-02
ElectricalData
*UX2 SCHEMATIC DIAGRAM
From Dwg. D342781P01
12 Pub. No. 12-1262-02
ElectricalData
*DX2 Schematic Diagram
From Dwg. D342782P01
13Pub. No. 12-1262-02
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY
FieldWiring
14 Pub. No. 12-1262-02
FieldWiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
15Pub. No. 12-1262-02
Twinning FieldWiring
16 Pub. No. 12-1262-02
Twinning FieldWiring
17Pub. No. 12-1262-02
Dimensions
Fro
m D
wg.
21C
3418
84 R
ev. 1
*UX
2 U
PFL
OW
/HO
RIZ
ON
TAL
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
Mo
del
(See
No
te 1
& 2
)D
IM "
A"
DIM
"B
"D
IM "
C"
DIM
"D
"D
IM "
E"
DIM
"F
"
*UX
2B06
0A93
62A
*UX
2B08
0A94
22A
17-1
/2"
2-1/
4"16
-1/4
"16
"7-
1/2"
2"
*UX
2C10
0A94
82A
21"
2-1/
2"19
-3/4
"19
-1/2
"9"
3"
*UX
2D12
0A96
02A
24-1
/2"
2-15
/16"
23-1
/4"
23"
10"
3"
* P
refix
May
Be
"A"
or "
T"
Not
es:
1. *
UX
2D12
0A96
02A
Req
uire
s 3"
Dia
met
er V
ent
Pip
e.*U
X2C
100A
9482
A
Req
uire
s 2-
1/2"
or
3" D
iam
eter
Ven
t P
ipe.
2. D
iam
eter
of V
ent P
Ipe
may
be
limite
d to
2-1
/2"
or 3
" on
som
em
odel
s at
diff
eren
t alti
tude
s. R
efer
to th
e V
ent L
engt
h Ta
ble
for
prop
er a
pplic
atio
n.
18 Pub. No. 12-1262-02
Fro
m D
wg.
21C
3418
85 R
ev. 1
*DX
2 D
OW
NFL
OW
/HO
RIZ
ON
TAL
OU
TLIN
E D
RA
WIN
G(A
LL D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
Mo
del
(See
No
te 1
)D
IM "
A"
DIM
"B
"D
IM "
C"
DIM
"D
"
*DX
2B06
0A93
62A
*DX
2B08
0A94
22A
17-1
/2"
2-1/
4"16
-1/4
"16
"
*DX
2C10
0A94
82A
21"
2-1/
2"19
-3/4
"19
-1/2
"
*DX
2D12
0A96
02A
24-1
/2"
2-15
/16"
23-1
/4"
23"
* P
refix
May
Be
"A"
or "
T"
Not
es:
1. D
iam
eter
of
Ven
t P
ipe
may
be
limite
dto
2-1
/2"
or 3
" on
som
e m
odel
s at
diffe
rent
alti
tude
s. R
efer
to
the
Ven
tLe
ngth
Tab
le fo
r p
rope
r ap
plic
atio
n.
19Pub. No. 12-1262-02
Notes
Since American Standard Heating & Air Conditioning has a policy of continuous product and productdata improvement, it reserves the right to change design and specifications without notice.
American StandardHeating & Air Conditioning6200 Troup HighwayTyler, TX 75707www.americanstandardair.com