AMD SPIN-ON FILTER FOR LOW PRESSURE LINE Pressure Filters

AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

AMD

SPIN-ON FILTER FOR LOW PRESSURE LINE

Pres

sure

Filt

ers

Page 2: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

Port sizes: 3/4” - 1” 1/2Flow rates: 7 ÷ 375 l/min.

TECHNICAL DATAMax. working pressure: 1,2 MPa (12 bar)Max. test pressure: 1,5 MPa (15 bar)Bursting pressure: 2,5 MPa (25 bar)Fatigue test: 0 ÷ 1,2 MPa (12 bar) / 100.000 cyclesBypass valve: 170 kPa (1,7 bar) ± 10%Filter element collapse pressure:standard: ∆p 400 kPa (4 bar) all types

Working temperature: -25 ÷ +110°C

MATERIALSHead: aluminiumSeals: standard NBR on request FKM

COMPATIBILITY (ISO 2943:1999)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4). For fl uids different than the above mentioned, please contact our Sales Department.

All tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test. For further information contact our Technical Dept.

1,2 MPa (12 bar)AMD

Pres

sure

Filt

ers

AM

D

Page 3: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

Seals Seals

12

1 = NBR Nitrile 2 = FKM Fluoroelastomer

1 = NBR Nitrile2 = FKM Fluoroelastomer

12

12

12

12

12

12

12

Ports

B = BSPF = SAE flange 3000 psi

B-

B-

B-

B-

B-

B-

BF

BF

Port size

4--

4 = 3/4”6 = 1” 1/47 = 1” 1/2”

4--

-6-

-6-

--7

--7

--7

--7

Bypass type

SB

S = WithoutB = Bypass 170 kPa (1,7 bar)

SB

SB

SB

SB

SB

SB

SB

Type Type

AMD

151 152 301 302 601 602 801 802

Complete Filter BMD Without can

CCA AMF 601 & 801 > 2xCCA301AMF 602 & 802 > 2xCCA302

Indicators

0UU0N0-----

0U = Port, pluggedU0 = Visual differential 130 kPa (1,3 bar)N0 = Electrical differential 130 kPa (1,3 bar)03 = Port, plugged5B = Visual differential 130 kPa (1,3 bar)6B = Electrical differential 130 kPa (1,3 bar)7B = 6B with LEDT0 = Electrical 130 kPa (1,3 bar) with thermostat 30°C

0UU0N0-----

0UU0N0-----

0UU0N0-----

---

035B6B7BT0

---

035B6B7BT0

---

035B6B7BT0

---

035B6B7BT0

Filter media Filter media

FTFCFDFVCDCVMSMN

FT = 5µm(c)

FC = 7µm(c)

FD = 12µm(c)

FV = 21µm(c)

CD = 10µCV = 25µMS = 60µMN = 90µ

FT = 5µm(c)

FC = 7µm(c)

FD = 12µm(c)

FV = 21µm(c)

CD = 10µCV = 25µMS = 60µMN = 90µ

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

FTFCFDFVCDCVMSMN

Accessories

XX = No accessory available

XX

XX XX XX XX XX XX XX XX

Inorganic fibres ß>1000

Paper

Steel wire mesh

Inorganic fibres ß>1000

Paper

Steel wire mesh

When the filter is ordered with FKM seals, the first digit of the indicator codeis a letter (please see page 188-189).

Indicator 70on request only

HOW TO ORDER THE COMPLETE FILTER HOW TO ORDER THE FILTER ELEMENT

Pres

sure

Filt

ers

AM

D

Page 4: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

D2

95

H1

H2

D1

D1

2023

H3

ø 96

21,5

38

M8

24,5

133

3038

D1

H1

H2

H3

ø 129

D3

D2

35

36

50M

8

D1

AMD 151...B

AMD 152...B

AMD 301...B

AMD 302...B

3/4” BSP

3/4” BSP

1” 1/4 BSP

1” 1/4 BSP

3/4” BSP

3/4” BSP

1” 1/2 16-UNF

1” 1/2 16-UNF

-

-

1” 1/4 BSP

1” 1/4 BSP

145

191

181

226

M8

M8

M8

M8

188

234

248

293

208

254

278

323

0,8

0,9

1,8

1,9

Type D1 D2 D3 D4 H1 H2 H3 Weight Kg

Indicator Port

Indicator Port

AMD 15 AMD 30

DIMENSIONAL LAYOUT(mm)

Pres

sure

Filt

ers

AM

D

Page 5: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

69,85

48

24

35,7

1

D2D3

D5H1

H2

H3

ø129

88 88

D4 1/8"

D1

15098 98 30°

1560147

80

D1

1/8"

D2D3

ø 129

145

625572

H1

H2

H1

H2

H3

D4

ø 129

AMD 601...B

AMD 602...B

AMD 801...B

AMD 802...B

AMD 801...F

AMD 802...F

1” 1/2 BSP

1” 1/2 BSP

1” 1/2 BSP

1” 1/2 BSP

1” 1/2 SAE 3000

1” 1/2 SAE 3000

1” 1/2 16 - UN

1” 1/2 16 - UN

1” 1/2 16-UN

1” 1/2 16-UN

1” 1/2 16-UN

1” 1/2 16-UN

1” 1/4 BSP

1” 1/4 BSP

1” 1/4 BSP

1” 1/4 BSP

1” 1/4 BSP

1” 1/4 BSP

181

226

181

226

181

226

-

-

-

-

M12

M12

M10

M10

M10

M10

M10

M10

216

261

269

314

269

314

246

291

299

344

299

344

3,4

3,8

4,7

5,1

4,7

5,1

Type D1 D2 D3 D5D4 H1 H2 H3 Weight Kg

Indicator Port

Indicator Port

AMD 60 AMD 80

DIMENSIONAL LAYOUT(mm)

Pres

sure

Filt

ers

AM

D

Page 6: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

32 20

M14Setting 130 kPa (1,3 bar)

NBR FKM

U0 W0

Differential VISUAL indicator

N.C.N.O.

63,5

35

27

M14

Setting 130 kPa (1,3 bar)

NBR FKM

N0 S0

Differential ELECTRICAL indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

64,5

30

4835

M20 x 1,5

G R231+

4-

N.C.N.O.C

Setting 130 kPa (1,3 bar)

NBR FKM

7B EB

Differential ELECTRICAL indicator with LED (24V) for visual indication

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

70

48

30

M20 x 1,5

Setting 130 kPa (1,3 bar)

NBR FKM

70 E0

Differential VISUAL ELECTRICAL indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

70

59

32

M20 x 1,5

Setting 130 kPa (1,3 bar)

NBR FKM

T0 DB

Differential ELECTRICAL indicator with THERMOSTAT 30°C

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

23

1

64,5

30

4835

M20 x 1,5

Setting 130 kPa (1,3 bar)

NBR FKM

6B CB

Differential ELECTRICAL indicator

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

35,5

30

ø 30

M20 x 1,5

Setting 130 kPa (1,3 bar)

NBR FKM

5B AB

Differential VISUAL indicator

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

CLOGGING INDICATORS

Pres

sure

Filt

ers

AM

D

Page 7: AMD - hydraulikNBR FKM U0 W0 Differential VISUAL indicator N.C. N.O. 63,5 35 27 M14 Setting 130 kPa (1,3 bar) NBR FKM N0 S0 Differential ELECTRICAL indicator SPDT differential switch

H2

H1

H3

H5

H4

E4E4

D 1

D2

E1

E3D

3

D1

E2

E5(*)

E

D

C

A

B

Type

CCA 151 ...

CCA 152 ...

CCA 301 ...

CCA 302 ...

95

95

129

129

62

62

98

98

72

72

108

108

0,6

0,7

1,15

1,4

145

191

181

226

3/4” BSP

3/4” BSP

1” 1/4 BSP

1” 1/4 BSP

A D E Weight KgB C

Type

AMD 151

AMD 152

AMD 301

AMD 302

AMD 601

AMD 602

AMD 801

AMD 802

30

34

87

92

190

205

190

205

35

41

102

110

242

255

242

255

48

55

118

125

270

283

270

283

65

69

125

135

280

292

280

292

68

74

130

150

290

305

290

305

73

80

170

188

325

340

325

340

80

90

190

205

360

375

360

375

80

90

190

205

360

375

360

375

FT FC FD FV CD CV MS MN

Media

Type

CCA 151...

CCA 152...

CCA 301...

CCA 302...

12,3

20,8

25,5

33,8

17,2

29,2

35,7

47,3

19,6

33,3

40,9

53,8

30,0

50,4

62,3

82,5

FT FC FD FV

Filter Media

980

1390

1940

2570

980

1390

1940

2570

3305

4745

5560

7360

3305

4745

5560

7360

MS MN CD CV

Filter Media

Tech

nica

l dat

a su

bjec

t to

varia

tions

with

out p

rior n

otic

e. A

MD

10/

2012

The reference fluid has a kinematic viscosity of 30 cSt and a density of 0,86 Kg/dm3.For different oil viscosity please contact our Sales Department for further information.

SPIN-ON ELEMENTS DIMENSIONAL LAYOUT(mm)

FLOW RATES(l/min)

DIRT HOLDING CAPACITY(g) ISO MTD ∆p = 400 kPa (4 bar)

FILTER AREA(cm2)