4
DRYTEC ALUMINIUM RANGE FINE FILTERS Flow rates from 25 to 2210 m³/h Pipe size from ¼” to 3”

Aluminium Range Fine Filters

Embed Size (px)

DESCRIPTION

Drytec Aluminium Range Fine Filters

Citation preview

Page 1: Aluminium Range Fine Filters

DRYTEC ALUMINIUM RANGE FINE FILTERS

Flow rates from 25 to 2210 m³/h Pipe size from ¼” to 3”

Page 2: Aluminium Range Fine Filters

High efficiency filtration elements

Color coded elements P X Y A Working temperature upto 80°C

(25°C for activated carbon element) Low initial pressure drop Dept filtration using 8 time

wrapped filter medium Maximum working pressure 16 bar Synthetic end-caps Strong Helix tube inner and outher

core

Why use DRYTEC compressed air filter ?

Differential pressure indicator as standard Aluminium housing for pressure upto 16 bars The housings are in-and outside protected

with an anti-corrosion coating Reliable float drain Screwed connetions fron ¼” to 3” Flow from 25 to 2210 m³/h Partical removal from 5 to 0,01 µ Maximum oil carryover from 5 to 0,003

mg/m³ @ 21°C

Page 3: Aluminium Range Fine Filters

* Maximum working pressure for filter G1510 and G2210 is 12 barg

When ordering don’t forget to indicate the filtration grade expected behind the filter code (ex. G300X)

m³/H CFM A B C D E

G25 1/4 25 15 1,36 M25 96 20 237 110 22

G50 3/8 50 29 1,36 M50 96 20 237 110 22

G100 1/2 100 59 1,37 M100 96 20 237 150 22

G150 3/4 150 88 3,12 M150 117 34 375 190 56

G200 3/4 200 118 3,29 M200 117 34 375 250 56

G250 1 250 147 3,49 M250 117 34 465 300 56

G300 1 1/4 300 176 3,38 M300 117 34 465 350 56

G500 1 1/4 500 294 3,83 M500 117 34 530 380 56

G600 1 1/2 600 353 3,84 M600 117 34 530 425 56

G851 2 851 501 10,01 M851 170 64 722 480 56

G1210 2 1210 712 10,43 M1210 170 64 722 550 56

G1810 3 1810 1065 19,10 M1810 235 72 760 550 56

G2210 3 2210 1300 19,64 M2210 235 72 760 600 56

Technical details

FilterModel

Pipe Size

(inches)

ElementModel

Housing Dimensions in mmFlow Rate Weight kg

PREFILTERING

GENERALUSE

OILREMOVAL

ACTIVATEDCARBON

Grade P X Y A5 1 0.01 0.015 0.5 0.01 0.003

80 80 80 2540 80 100 80

700 700 700 70016 16 16 16

Green Blue Red Metal

SPECIFICATION AIR FLOW

Particle in Microns

Max. working pressure in bars *Element colour code

SPECIFICATION

Max. Oil Carry over at 21°C (mg/M³) Max. Working temperature (°C)Initial pressure loss (mbar)Pressure loss for element change (mbar)

1 3 5 7 9 11 13 15 160.5 0.71 0.87 1 1.12 1.22 1.32 1.44 1.50

Operating pressure in barFor the max flow rate, multiply above flow rate shown in the above table with the

correction factor.Operating pressure in bars

Correction factor

Page 4: Aluminium Range Fine Filters

Subject to technical changes without prior notice

Your dealer

Different options available

Filter elements for other housings