16
® Alphion AONT-100C (SFU) Catalog Number: AONT-100C-DOC-03 Part Number: 196-0000002 Rev 02

Alphion AONT-100C (SFU) User Guide

Embed Size (px)

DESCRIPTION

Alphion AONT-100C (SFU) User Guide

Citation preview

Page 1: Alphion AONT-100C (SFU) User Guide

®

Alphion AONT-100C (SFU)

Catalog Number: AONT-100C-DOC-03Part Number: 196-0000002 Rev 02

Page 2: Alphion AONT-100C (SFU) User Guide

PART NUMPUBLISHED

ALPHION C196 PRINCBUILDING 1PRINCETON

WWW.ALP

Alphion AONT-100C (SFU) User Guide

Catalog Number: AONT-100C-DOC-03Part Number: 196-0000002 Rev 02

BER: 196-0000002 REVISION 02: MARCH 2008

ORPORATIONETON HIGHTSTOWN ROADA JUNCTION, NJ 08550

HION.COM

Page 3: Alphion AONT-100C (SFU) User Guide

2

COPYRIGHT

Copyright © 2008 Alphion Corporation, Inc.

All Rights Reserved. Printed in U.S.A.

Alphion AONT-100C (SFU) User Guide

Catalog Number: AONT-100C-DOC-03

Part Number: 196-0000002 Revision 02

March 2008

TRADEMARKS

All of the Alphion names, brand names, and product names referred to in this Document, in particular, the name “Alphion” and its logo, are either registered trademarks or trademarks of the Alphion Corporation. All other registered trademarks or trademarks are the property of their respective owners.

LIMITED WARRANTY

Alphion warrants that this Document has been delivered free of all rightful claims of any third person by way of infringement or the like of any copyright, trade secret, or trademark. THIS DOCUMENT AND THE PRODUCTS DESCRIBED THEREIN (COLLECTIVELY, THE “DELIVERABLES”) ARE PROVIDED “AS IS” AND ALPHION MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, AND DISCLAIMS ANY AND ALL OTHER WARRANTIES WITH RESPECT TO THE DELIVERABLES, OR ANY MODIFICATIONS THERETO, IN WHOLE OR IN PART, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ALPHION OR ANY ALPHION EMPLOYEE BE LIABLE FOR THE ACCURACY OR COMPLETENESS OF THE DELIVERABLES.

Page 4: Alphion AONT-100C (SFU) User Guide

EXCLUSION OF CONSEQUENTIAL DAMAGES; LIMITATION OF LIABILITY

ALPHION SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO BUYER FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR INDIRECT DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES, EVEN IF ALPHION HAS BEEN APPRISED OF THE LIKELIHOOD OF SUCH DAMAGES. IN NO EVENT SHALL ALPHION'S LIABILITY TO BUYER FOR DAMAGES ARISING OUT OF OR RELATED TO THE DELIVERABLES EXCEED THE AGGREGATE PRICE OF THE DELIVERABLES.

3

Page 5: Alphion AONT-100C (SFU) User Guide

4

Page 6: Alphion AONT-100C (SFU) User Guide

In this guide

Before you begin, please read all safety information on page 10.

This guide covers information on the following:

■ Connecting the AONT-100C on page 6

■ Verifying Connections on page 9

■ Troubleshooting on page 10

■ Safety on page 12

Figure 1 Alphion AONT-100C

5

Page 7: Alphion AONT-100C (SFU) User Guide

6

Connecting the AONT-100C

To set up the connections for the AONT-100C, follow the instructions below:

Connect the Network

The network connection should already be established. If it is not, please contact your service provider.

Connect PowerConnect the power adapter to the power connector on the side of the unit.

Plug the power adapter into an electrical outlet.

Verify that the POWER LED on the front of the unit is solid green.

Verify that the FIBER LED on the front of the unit is solid green (not flashing).

Connect Data ServiceConnect Ethernet cables to the Ethernet ports on the side of the unit.

Connecting the AONT-100C

Page 8: Alphion AONT-100C (SFU) User Guide

Configure PPPoE on a Client in Windows XP1 From your desktop, click Start. Choose Connect To>>

Show All Connections.2 In the left panel, click Create a New Connection. The New

Connection Wizard opens.3 Click Next.4 Select Option 1, “Connect to the Internet.” Click Next.5 Select Option 2, “Set Up My Connection Manually.” Click Next.6 The Wizard asks “How do you want to connect to the Internet?”

Selection Option 2, “Connect Using a Broadband connection that requires a user name and password.” Click Next.

7 Enter a name for the connection. Click Next.8 Enter the Username and Password as configured in the server

(/etc/ppp/pap-secrets.)9 Click Finish. A new connection now exists in the Network

Connections box.10 To establish a PPPoE connection, right-click the Newly Created

Network Connection and select Connect.11 Click Connect. The client dials the PPPoE Connection.For instructions on how to configure PPPoE in a Microsoft Vista operating environment, go to www.microsoft.com and search on the term “PPPoE.”

Connecting the AONT-100C 7

Page 9: Alphion AONT-100C (SFU) User Guide

8

Connect Phone ServiceConnect phone wires to the phone ports on the side of the unit.

Figure 2 Connection Ports on Side of Unit

Reset

PWR

TEL1ETH1

ETH2ETH3

ETH4TEL2

Power 12VDC

Reset

Link LED(green)

Activity LED(amber) Ethernet Ports

Phone Ports

Connecting the AONT-100C

Page 10: Alphion AONT-100C (SFU) User Guide

Verifying Connections

To verify that all the connections are active, check the LEDs on the front of the unit.

Figure 3 LEDs on Front of Unit

They should appear as follows:

POWER Green

FIBER Green

DATA Green (if data service is enabled)

UPDATE Off (unless software upgrade is in progress)

TEST Off

PHONE Off (or green if phone is off the hook)

Verifying Connections 9

Page 11: Alphion AONT-100C (SFU) User Guide

10

Troubleshooting

Below are the LED states with an explanation of each. If a problem is indicated, see Getting Support.

POWER Solid green Operating from AC power

Flashing green Operating from battery power

Red Operating from battery power and battery is low

FIBER Solid green Network is fully operational

Flashing green Network is in ranging and synchronizing process—should change to solid green within approximately 1 minute

Red Unrecoverable failure of hardware or software self test

Off Unit is not operational

Troubleshooting

Page 12: Alphion AONT-100C (SFU) User Guide

DATA Solid green At least one Ethernet link is active

Flashing green At least one Ethernet link is active and receiving/transferring data

Off Ethernet service is not enabled or Ethernet link is not established

UPDATE Flashing green Software download is in progress. Do not turn power off while flashing

Off No software update in progress

PHONE Solid green At least one phone is in use/off the hook

Flashing green At least one phone has been in use/off the hook for more than one hour

Off Telephone service not established or all phones connected to unit are on the hook

Troubleshooting 11

Page 13: Alphion AONT-100C (SFU) User Guide

12

Getting SupportPlease contact your local service provider for support. Be prepared to provide the model and serial number of your unit.

Safety

Read the information below for important safety reminders.

Electrical Safety■ Always use caution when handling electrical connections.■ Never install electrical equipment in wet or damp conditions.■ Be sure that the power source for the system is adequately rated

to assure safe operation and provides current overload protection.■ Ensure nothing is allowed to rest on the power cable.■ Ensure the power cable will not be walked or stepped on.■ To avoid electric shock caused by over-voltage from the public

telephone network, do not connect this unit to an external telephone connection.

■ Use only the power adapter supplied with this unit.

Caution: This unit does not contain any user-serviceable parts. Opening the housing on this unit will void the warranty.

Safety

Page 14: Alphion AONT-100C (SFU) User Guide

Laser Safety

Caution: Do not use controls, adjustments, or procedures other than specified. This could result in hazardous laser radiation exposure.

Never look directly into an unterminated cable or connection. Invisible laser radiation may be emitted from the ends of unterminated fiber cables or connectors.

The AONT-100 uses a Class I laser device.

Safety 13

Page 15: Alphion AONT-100C (SFU) User Guide

14

Safety

Page 16: Alphion AONT-100C (SFU) User Guide

Catalog Number: AONT-100C-DOC-03Part Number: 196-0000002 Rev 02April 2008