Agricultural Designed Motors amp Controls
508A
Agricu
ltural C
atalog
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer expectations for quality performance and reliability at the lowest possible cost and delivered within the customerrsquos schedule through our authorized distribution network
COMPANY HISTORY
In 1993 North American Electric began sourcing high quality high performance electric motors and gearing from around the world and distributed the on a national and international level In 2014 we opened our NAE Motor Controls division enabling us to offer our wholesale distribution network complete automation solutions
Controls Motors Gear Reducers
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)
CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)
ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled
SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available
CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)
MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)
SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet
SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction
THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet
THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)
THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction
ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)
GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)
ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Program
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
ldquoNo Hasslerdquo Chassis
Exchange Program
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage
protection Single phasing phase reversal and voltage
unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis
(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)
Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance
ldquoProviding reliable control panel
service for up to six (6) yearsrdquo
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer expectations for quality performance and reliability at the lowest possible cost and delivered within the customerrsquos schedule through our authorized distribution network
COMPANY HISTORY
In 1993 North American Electric began sourcing high quality high performance electric motors and gearing from around the world and distributed the on a national and international level In 2014 we opened our NAE Motor Controls division enabling us to offer our wholesale distribution network complete automation solutions
Controls Motors Gear Reducers
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)
CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)
ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled
SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available
CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)
MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)
SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet
SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction
THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet
THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)
THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction
ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)
GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)
ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Program
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
ldquoNo Hasslerdquo Chassis
Exchange Program
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage
protection Single phasing phase reversal and voltage
unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis
(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)
Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance
ldquoProviding reliable control panel
service for up to six (6) yearsrdquo
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)
CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)
VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)
ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled
SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available
CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)
MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)
SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet
SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction
THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet
THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)
THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction
SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction
ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)
GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)
ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Program
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
ldquoNo Hasslerdquo Chassis
Exchange Program
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage
protection Single phasing phase reversal and voltage
unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis
(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)
Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance
ldquoProviding reliable control panel
service for up to six (6) yearsrdquo
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Program
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
ldquoNo Hasslerdquo Chassis
Exchange Program
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage
protection Single phasing phase reversal and voltage
unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis
(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)
Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions
NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance
ldquoProviding reliable control panel
service for up to six (6) yearsrdquo
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6
COUPLING
INCLUDED IN PRICE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Corrosion Resistant Epoxy Paint
⓲ Lifting Provisions
⓳ Two (2) Year Warranty (Extended Warranty Available)
⓴ Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER RATED (101 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V1 SERIES
VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V1 SERIESmdash INVERTER RATED (101 VT)
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V
3 Zinc Plate Steel Frame Construction
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
Standard Features Include ❶ 10 HPmdash500 HP in Stock
❷ 115 Service Factor 60 Hertz
❸ Oversized Angular Contact Bearing and Ball Bearing
Insulated Bearing Mount (40 HPmdash500 HP)
High Thrust (10 HPmdash250 HP)
Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance
❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1
❾ Non-Reverse Ratchet (Ball Type)
❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V
Single Voltage Ratings are Suitable for Part Wind Start at 460V
⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)
⓬ Cast Iron Plate Steel Frame Construction
⓭ Light Weight Hood for Easy Access
⓮ Space Heaters
⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)
⓰ Thermal Protected
⓱ Windings Rated for 2200V Peak Voltage Spikes
⓲ Corrosion Resistant Epoxy Paint
⓳ Lifting Provisions
⓴ Two (2) Year Warranty (Extended Warranty Available)
mdash Parts and Accessories Available5
APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives
COUPLING
INCLUDED IN PRICE
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
INVERTER DUTY (201 VT)
HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME
OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE
V2 SERIES
VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust
1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction
LIGHTWEIGHT HOOD
OIL PLUG
SIGHT GAUGE
Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11
Warranty on p 64
V2 SERIESmdash INVERTER DUTY (201 VT)
4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TIC
AL
HO
LLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
REPLACEMENT PARTS
V1 AND V2 SERIES
AccessoriesmdashVHS V1 and V2 Series
Ball Bearing Non-Reverse Ratchet Assembly
Lubriport Sight Glass
Model Number HP FrameWeight
(lbs)
Mult
Symbol List Price
SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases
Top Cover
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
VER
TICA
L H
OLLO
W
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11
AccessoriesmdashVHS V1 and V2 Series
10 HPmdash500 HP VERTICAL HOLLOW SHAFT
MOTOR COUPLINGS
V1 AND V2 SERIES
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
R
OLL
ED
STE
EL
12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)
APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque
13 HPmdash10 HP FARM DUTY ROLLED STEEL
56Cmdash215T FRAME
SINGLE PHASE TEFC
Performance Data Dimensions found at naemotorscom
Warranty on p 64
sup1 Removable Feet on 56CCH motors only
sup2 Does not have Manual Overload Protection
Standard Features Include ❶ 13 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility1
❾ Manual Overload Protection (13 HPmdash5 HP)
❿ Capacitor Start Capacitor Run Design
⓫ Corrosion Resistant Epoxy Paint
⓬ Lifting Provision on 182T and Above
⓭ Condensation Drains with Plugs
⓮ IP55 Protection
⓯ Two (2) Year Warranty
⓰ C-Flange Field Conversion Kits Available
SINGLE PHASE
56Cmdash56CH
143Tmdash145T
213Tmdash215T
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
R
OLLED
STEEL
13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
1 HPmdash10 HP GENERAL PURPOSE
ROLLED STEEL
143Tmdash215T FRAME THREE-PHASE
TEFC
General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12
Standard Features Include ❶ 1 HPmdash10 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
❸ Sealed Bearings
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Corrosion Resistant Epoxy Paint
❿ Lifting Provision
⓫ Condensation Drains with Plugs
⓬ IP55 Protection
⓭ Three (3) Year Warranty (Extended Warranty Available)
⓮ C-Flange Field Conversion Kits Available
Performance Data Dimensions found at naemotorscom
Warranty on p 64
THREE-PHASE
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
14
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Standard Features Include ❶ 1 HPmdash600 HP in Stock
❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz
Suitable for 575V 10 Service Factor
❸ Sealed Bearings Through 215T Frame
Regreasable Open Bearings 254T Frame and Above
Insulated Bearing on ODE Available on 444T and Above
❹ Class F Insulation System Class B Rise at Full Load
Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings
❺ 40o C Ambient Continuous Duty
❻ Stainless Steel Nameplate and Zinc Plate Hardware
❼ NEMA Design B Performance High Starting Torque
❽ Feet are Dual Drilled for Mounting Flexibility
❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage
Single Voltage (460V) Ratings are Suitable for Part Wind Start
❿ Corrosion Resistant Epoxy Paint
⓫ F1 F2 Reversible
⓬ Lifting Provision
⓭ Condensation Drains with Plugs
⓮ Windings Rated for 2200V Peak Voltage Spikes
⓯ IP55 Protection
⓰ Three (3) Year Warranty (Extended Warranty Available)
⓱ C-Flange amp D-Flange Field Conversion Kits Available
1 HPmdash300 HP
350 HPmdash600 HP
APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
16
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
G
ENER
AL
PU
RP
OSE
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17
General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G
Performance Data Motor Dimensions found at naemotorscom
Warranty on p 64
1 HPmdash600 HP GENERAL PURPOSE
CAST IRON
143Tmdash5867UZ FRAME THREE-PHASE
TEFC
1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V
5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)
SAFE
TY
SWIT
CH
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18
Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE
HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Two (2) Year Warranty Most Orders Ship Within
24 HOURS
Warranty on pp 60mdash61
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584
SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604
SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852
SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936
SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936
SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344
SAFETY
SW
ITC
H
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19
Warranty on pp 60mdash61
Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated
PROTECTS AGAINST LIGHTNING STRIKES
AND EXTREME SURGES
480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT
w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED
NEMA 3R ENCLOSURE HEAVY DUTY RATED
NON-FUSED or FUSED w FLANGED
Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock
❷ NEMA 3RmdashHeavy Duty Enclosure
❸ 3-Pole 3-Wire Non-Fused or Fused
❹ Rated for 480VAC 600VAC
❺ Highly Visible Easy-to-Grip Handle
❻ Visible Blade Construction
❼ Door Opens 180deg or Greater
❽ All Copper Current Carrying Parts
❾ Quick-Make Quick-Break Mechanism
❿ Positive Two and Three Point Mounting
⓫ Front Removable Lugs Can Easily be Converted
to Copper Body or Compression Type Lugs
⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)
⓭ Padlockable Cover Latches and Disconnect Handle
⓮ UL 508A Certified
⓯ Three (3) Year Warranty with ldquoLightning
amp Surgerdquo Protection
Most Orders Ship Within
24 HOURS
NON-FUSED
Neutral Kit Options
Model Number Amp Rating Volt Description List Price
SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270
SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080
ATL
20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ATL SERIES ACROSS THE LINE - STARTER PANELS
Model Number Assembler
Select the option code from each box to build your control panel
ATL-IRR-460-N3-BRKR-13A-000
Product Series
ATL ndash Across the Line
Supply Voltage
230 ndash 240V
460 ndash 480V
Series
IRR ndash Irrigation
NEMA Size
N1 ndash 1
N2 ndash 2
N3 ndash 3
N4 ndash 4
N5 ndash 5
Disconnect Type
FUSD ndash Fused
BRKR ndash Circuit Breaker
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available mdash Please
refer to page 27 or contact us at
800-884-0404 for assistance
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 27)
ATL
21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor
ATL
22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for
Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor
ATL
23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP
CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect
❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
ATL
24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor
Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload
One Overload Covers Entire HP (Amp) Range for Each NEMA Size
❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Most Orders Ship Within
24 HOURS
Options on p 27 Warranty on pp 60mdash61
240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER
w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED
NEMA 3R ENCLOSURE
FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED
ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)
240V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70
480V with 120V Transformer NEMA
Model Number Size H W D
ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$
ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$
ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$
ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$
ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$
HPsup1Amp
Range
Dimensions (Inches)Weight List Price
Weight List Price
Mult
Symbol
Mult
SymbolHPsup1
Amp
Range
Dimensions (Inches)
ATL
25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61
240V 1 HPmdash100 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
480V 1 HPmdash200 HP WASHDOWN
ACROSS THE LINE STARTER w120V TRANSFORMER
CIRCUIT BREAKER NEMA 4X ENCLOSURE
IEC RATED CONTACTOR
CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect
❹ IEC Rated Contactor
❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
Options on p 27 Warranty on pp 60mdash61
ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)
ATL
27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
TC75 34 Diameter $2722
TC100 1 Diameter $2722
TC125 1 14 Diameter $1577
TC150 1 12 Diameter $2722
TC200 2 Diameter $2722
TC250 2 12 Diameter $1603
TC300 3 Diameter $7011
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
- We Stock Fuses for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
FUSES
SPACE HEATERS3
MISCELLANEOUS
PROTECTION MECHANISMS3
METERS3
TIMERS3
UNIVERSAL RAINTIGHT HUBS
ADVANCED FAULT STATUS MONITORING OPTIONS3
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS3
SELECTOR SWITCHES
PA
RT
WIN
D
STA
RT
ERS
28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
1000 SERIES ATLPWS STARTER PANELS
Model Number Assembler
1100B-1004TCE1-13A-4-000 Product Series
1 - Starter
Series
0 - ATL
1 - PWS
2 - Submersible
3 - Wye - Delta
4 - Duplex
9 - Operator Station
Disconnect Type
B - Breaker
D - Disconnect
F - Fused
N - None
Control Voltage
A - 208VAC60HZ
H - 120VAC60HZ
B - 240VAC60HZ
C - 480VAC60HZ
D - 24VDC
Overload
XX ndash None
T1 - Thermal Class 10
T2 - Thermal Class 20
T3 - Thermal Class 30
E1 - Electronic Class 10
E2 - Electronic Class 20
E3 - Electronic Class 30
E4 - Elec Class 5-10-20-30
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 31)
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
refer to page 31 or contact us
at 800-884-0404 for assistance
Type
00 - 3Ph Non Reversing
10 - 3Ph Reversing
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
030 - 30
hellip
hellip
NS1 - NEMA Size 1
NS2 - NEMA Size 2
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
PA
RT W
IND
STA
RT
ERS
29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available
Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash200 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
CIRCUIT BREAKER NEMA 3R ENCLOSURE
IEC RATED CONTACTORS 240V 10 HPmdash75 HP
480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
PA
RT
WIN
D
STA
RT
ERS
30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61
240V480V 10 HPmdash100 HP PART WIND STARTER
IRRIGATION PUMP w 120V TRANSFORMER
FUSED NEMA 3R ENCLOSURE
IEC RATED CONTACTORS
240V 10 HPmdash50 HP 480V 10 HPmdash100 HP
FUSED wTHROUGH-DOOR
PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)
Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors
❺ Thermal Overload (Class 20) w Phase Loss Protection
❻ Overload Reset Pushbuttons
❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available
PA
RT W
IND
STA
RT
ERS
31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
001 ATL PWS Overload Reset Pushbutton $15552
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
FUSES - We Stock Fuses for Convenience Please Call for Pricing
SPACE HEATERS034 Space Heater with Thermostat $46008
MISCELLANEOUS054 Transformer $16092
PROTECTION MECHANISMS41 Surge suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
METERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
SOFT
ST
AR
TER
S
32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Model Number Assembler
3032B-1004TP00-13A-4-000 Product Series
3 - RVSS
Torque
0 - Normal Duty
1 - Heavy Duty
2 - Submersible
Drive BrandSeries
20 - SAF MS6
31 - ABB PSR
32 - ABB PSE
40 - Siemens 3RW30
41 - Siemens 3RW40
42 - Siemens 3RW44
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
6 - 6903PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility
Status Light
030mdashElapsed Time Meter
mdash Multiple Options
Available (p 35)
Horsepower
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
hellip
hellip
700 - 700
Purpose
P00mdashGeneral
Purpose
Control Option Package
Eg 13A HandOff Auto (HOA)
Start Pushbutton
Overload Reset Button
Other Options Available - Please
Refer to page 35 or contact us
at 800-884-0404 for assistance
3000 SERIES RVSS (SOFT STARTER) PANELS
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon
N4 - NEMA 4 4FmdashNEMA 4X Fiberglass
4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
SOFT
STA
RT
ERS
33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 SOFT STARTER
IRRIGATION PUMP NORMAL DUTY
NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
SOFT
ST
AR
TER
S
34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35
Warranty on pp 60mdash61
240V480V SIEMENS 3RW40 WASHDOWN
SOFT STARTER NORMAL DUTY
NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP
480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR
Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device
Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device
Integrated ByPass Contact System
Adjustable Current Limiting
Intrinsic Device Protection
LED Status Fault Monitoring
Remote Reset
Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available
SOFT
STA
RT
ERS
35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67
MotorSaverreg is a registered trademark of SymCom Inc
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SPACE HEATERS
METERS
TIMERS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
2000 SERIES VARIABLE FREQUENCY DRIVE PANELS
Model Number Assembler
2010B-1004TP00-13M-4-000
Environmental Enclosure Rating
N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged
Product Series
2 - VFD
Horsepower
005 - 5
7P5 - 75
010 - 10
015 - 15
020 - 20
025 - 25
030 - 30
700 - 700
Disconnect Type
B - Breaker
F - Fused
N - None
Supply Voltage
1 - 2083PH
2 - 2403PH
4 - 4803PH
5 - 5753PH
Specification Information
000mdashNone
SPCmdashSpecial Instructions
065mdashHigh Visibility Status Light
mdash Multiple Options Available
(pp 49mdash50 62mdash64)
Purpose
P00 - General Purpose
P01 - Irrigation (IRR)
P02 - Positive Displacement
Pump (PDP)
P1B - ReGen Avoidance
P1C - ReGen Drive
INT - Integrator
Torque
0 - VT (120) Normal Duty
1 - CT (150) Heavy Duty
2 - Submersible
4 - Duplex
Control Option Package
Eg 13M HandOff Auto (HOA)
Start Pushbutton
1 Turn Potentiometer
Other Options Available - Please
refer to pp 49mdash50 62mdash64 or
contact us at 800-884-0404 for
assistance
Drive BrandSeries
1x - LSIS
10 - IS7
11 - C100
12 - H100
13 - S100
14 - S100 4X
5x - SIEMENS
50 - G120
55 - G120X
51 - G130
52 - V20
VFD
s
37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓱ Other Options Available
LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP
CIRCUIT BREAKER
Options on pp 43mdash44 Warranty on pp 60mdash61
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
VFD
s
39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 1 HPmdash60 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include
❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
1 HPmdash75 HP
10 HP
15 HPmdash60 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
LSis S100 and iS7 IRRIGATION PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 1 HPmdash150 HP CIRCUIT BREAKER
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
1 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash150 HP
Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 2
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Options on pp 43mdash44 Warranty on pp 60mdash61
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 240V VARIABLE TORQUE
NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
5 HPmdash5 HP
75 HPmdash10 HP
15 HPmdash30 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives
5 HPmdash75 HP
10 HPmdash20 HP
25 HPmdash125 HP
LSis S100 and iS7 SUBMERSIBLE PACKAGE
1-PHASE to 3-PHASE 480V VARIABLE TORQUE
NEMA 3R ENCLOSURE
480V 12 HPmdash125 HP CIRCUIT BREAKER
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance
Options on pp 43mdash44 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Drive Configured Utilizing VHz Control 3
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024
008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172
065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222
027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488
031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960
116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240
066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720
052 Two Way Cellular Communication amp Functionality
061 Cloud Based Remote Monitoring
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940
151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592
155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
POTENTIOMETERS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
VFD
s
44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000
one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092
072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MODEL
NUMBERDESCRIPTION
VFD
s
45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Siemens VFD Packages V20 G120X G120G130 Series
VFD
s
46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP
CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
1 HPmdash10 HP
60 HPmdash200 HP
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
15 HPmdash50 HP
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)
❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)
⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash40 HP FUSED w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57
Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available
VFD
s
50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad
SIEMENS V20 ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR
Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available
Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
VFD
s
51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61
Standard Features for Base Model Include ❶ 1 HPmdash200 HP
❷ NEMA 4XmdashStainless Steel Enclosure
❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient
❹ Combination Circuit Breaker Disconnect
Through-Door
❺ Easy-to-Use Drive for Basic Applications
Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering
❻ Surge Suppressor
❼ Start Pushbutton
❽ Hand Off Auto (HOA) Selector Switch
❾ Potentiometer (Speed Pot)
❿ Padlockable Door and Disconnect
⓫ Service Entry Rated
⓬ UL 508A Certified
⓭ Standard Two (2) Year Warranty or
OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection
INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program
⓮ Other Options Available
VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
SIEMENS G120X ECONOMY PACKAGE
480V VARIABLE TORQUE NEMA 4X ENCLOSURE
RATED 32deg C90deg F INDOOR AMBIENT
480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR
Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)
VFD
s
52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash700 HP
CIRCUIT BREAKER
1 HPmdash10 HP
60 HPmdash400 HP
15 HPmdash50 HP
Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X IRRIGATION PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 1 HPmdash200 HP
FUSED
1 HPmdash10 HP
60 HPmdash200 HP
15 HPmdash50 HP
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
VFD
s
54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS V20 and G120 SUBMERSIBLE PACKAGE
240V VARIABLE TORQUE NEMA 3R ENCLOSURE
240V 12 HPmdash30 HP
CIRCUIT BREAKER
12 HPmdash3 HP
25 HPmdash30 HP
5 HPmdash20 HP
Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering
❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance
❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
Red = Fault
Blue = Backspin Mode
Green = Running
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2
VFD
s
55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIEMENS G120X SUBMERSIBLE PACKAGE
480V VARIABLE TORQUE NEMA 3R ENCLOSURE
480V 12 HPmdash200 HP
CIRCUIT BREAKER
12 HPmdash75 HP
50 HPmdash200 HP
10 HPmdash40 HP
Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application
PID Loop Control Capable with Analog Input
Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events
Line SidemdashLightning Surge and Severe Overvoltage
Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available
sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor
INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM
Options on pp 56mdash57 Warranty on pp 60mdash61
VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design
Red = Fault
Blue = Backspin Mode
Green = Running
VFD
s
56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on p 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
004 Start Pushbutton $14904
005 Stop Pushbutton $14904
043 Start Stop Pushbutton $20412
007 Jog Pushbutton $14904
009 Raised Pushbutton - Specify Color and Function $14904
010 Flush Pushbutton - Specify Color and Function $16416
011 Mushroom Type Pushbutton - Specify Color and Function $22842
012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904
006 Run Light $17172
013 Stop Light $17172
023 Power On Light $17172
014 Fault Light $17172
015 Ready Light $17172
016 Bypass Light $17172
017 Red Light - Specify Function $17172
018 Green Light - Specify Function $17172
019 Amber Light - Specify Function $17172
020 White Light - Specify Function $17172
021 Blue Light - Specify Function $17172
022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892
024 Hand - Off - Auto HOA Selector Switch $21546
025 Local - Off - Remote Selector Switch $21546
026 Key Operated Hand - Off - Auto Selector Switch $35640
002 Two Position Selector Switch - Specify Function $17496
003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type
032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768
028 Ammeter $34452
029 Voltmeter $34452
030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function
037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200
044 Door Mounted Keypad $27540
045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240
055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320
110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760
040 Murphy Switch Interface W Fault Recall Function $172044
067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160
052 Two Way Cellular Communication amp Functionality
200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920
201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824
202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944
203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208
204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848
205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568
206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752
207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524
208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296
209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring
POTENTIOMETERS
MODEL
NUMBERDESCRIPTION
PUSHBUTTONS
PILOT LIGHTS
SELECTOR SWITCHES
METERS
TIMERS
OTHER DOOR MOUNTED OPTIONS
ADVANCED FAULT STATUS MONITORING OPTIONS
VFD
s
57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
3 Additional information on pp 64
Please email salesnaemotorscom or contact us at 800-884-0404 for assistance
Motor Controls Panel Customization Made Easy
sup1 Multiplier Symbol 2 Warranty on pp 68mdash69
2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST
PRICE (w Installation)
073 V20 Smart Access $19656
074 V20 BOP - Basic Operator Panel for V20 Drive $5616
075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348
076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344
077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3
$196236
150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820
152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268
153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004
154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148
100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320
101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860
102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000
105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000
- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing
034 Space Heater with Thermostat $46008
054 Transformer $16092
041 Surge Suppressor $33156
115 SymCom MotorSaverreg Model 460 $22032
064 dV dT Filters
062 IEEE 519 Passive Harmonic Filter
063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing
phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program
070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292
071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692
SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084
SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000
SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000
SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808
SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400
SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400
SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368
SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452
PROTECTION MECHANISMS
MAIN LINE ONLY BOXES
FLOOR STANDS
PROGRAMMABLE RELAY OPTIONS
PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS
SENSOR OPTIONS
FUSES
SPACE HEATERS
MISCELLANEOUS
SIEMENS DRIVE CHASSIS OPTIONS
MODEL
NUMBERDESCRIPTION
VFD
s
58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes
VFDmdashControl Options CONTROL OPTIONS
Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE
ADVANCED OPERATOR PANEL
Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11
HUMAN MACHINE INTERFACE PANEL
SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation
Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL
SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1
SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet
SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings
Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING
BASIC OPERATOR PANEL (BOP-2)
SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided
Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL
INTELLIGENT OPERATOR PANEL (IOP-2)
VFD
s
59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
VFDmdashSpecial Enclosure Feature NEMA 3R Only
53rdquo AND UP ADVANCED TUNNEL DESIGN
SPECIAL FEATURE
40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY
53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)
45deg C 113deg F VT and CT (G120X)
Significantly Reduces Contaminants
Advanced Tunnel Design for Maximum Cooling
Patent Pending
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below
CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series
Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series
ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice
Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)
Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection
INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice
(Customer must review approve and sign drawings prior to panel being released for production)
Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight
ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded
ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE
Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report
Step 2 Contact our warranty department and be prepared to provide the following information and documentation
1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair
Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work
Visit our website at wwwnaemotorscom for detailed information and instructions on the following
1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and
Procedure
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY
WITH
ldquoLIGHTNING amp SURGErdquo PROTECTION
Terms amp Conditions of Sale
ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages
ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as
Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance
NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded
The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design
andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events
Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance
ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)
OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following
Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo
Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below
How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule
wwwnaemotorscomchassisexchangeprogram
ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our
ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement
chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of
the replacement invoice WARRANTY EXCLUSIONS
1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as
a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled
7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes
This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY
Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner
Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes
Note Please make a legible photo copy of the nameplate from the failed motor for your records
STANDARD LIMITED WARRANTY POLICY
General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice
North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following
1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced
For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
NAE University offers professional com-
prehensive and educational programs in-
cluding
SalesProduct Training Motors Controls
Motor Start Up Basic Programming of Low Voltage AC Drives
Maintenance and Troubleshooting Training
Motors Controls
We provide in depth hands on training at
our headquarters in Hernando Mississippi
We also provide on-site training at your
location as well as internet courses and
webinars
For more information please visit our
website at wwwnaemotorscom or
contact us at 800-884-0404
CONTINUING EDUCATION
CONTINUING EDUCATION
North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives
naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021
8008840404 salesnaemotorscom
naemotorscom PO Box 130 350 Vaiden Drive
Hernando MS 38632
General Purpose Motors amp More
508A Certified