Allan Korsgaard PoulsenHead of Section, PhDTracer specialist+45 72 20 18 [email protected]
Troels Bach NielsenConsultant+45 72 20 28 33 [email protected]
Teknologiparken
Kongsvang Allé 29
DK-8000 Aarhus C
Tel. +45 72 20 18 01
Fax +45 72 20 18 70
www.teknologisk.dk
DTI Oil & Gas Technical Team Hotline +45 72 20 24 [email protected]/oil
Tracer services from the Danish Technological InstituteWe offer a complete range of tracer operation services: Design, legal authorization, injection equipment, chemical sourcing, tracer injection, sampling, sample equipment and logistics, training of local personnel, analyses, interpretation and report-ing.
Interwell tracer test•Optimize [reservoir development and] sweep through knowledge of direct communication between wells•Low-cost,non-intrusiveoperations•Getresultsfastwithuniqueon-site analysis or sample and ship to the analysis laboratory
We offer two types of interwell tracer tests:•Interwell tracer testwith chemical tracer – Injection of water soluble inert chemical tracer and sampling from the relevant production wells. AnalysesaredoneatDTILabfacili- ties (onshore)•Interwell tracer test with deute- rated water tracer – Technology has been developed in cooperation with Maersk oil, and successfully applied in the Danish North Sea. Deuteratedwater(D2O)isinjected and watersamples from the produc- tion well are analyzed on-site according to D2O content. The on-site results enable for immediate decision making and planning of the follow-
ing tracer test, which could include, change in injection rates, opening/ closing a section of the well etc. Tracer tests with deuterated water have proven especially valuable for characterizationofhighflowfractures, for reference see SPE-154878
Single well Chemical tracer test•Investigatehydrocarboncontent in the vicinity of wells•IdealforevaluationofEORtests
Matrix tracer test•Investigate large-scale fluid move- ment in the reservoir•Complex flow-patterns are tracked by applying multiple different tracers•Analysisinhighlyexperiencedlabo- ratory
Near wellbore tracer test
Intrusion of drilling fluid•Ensuredependablecoringbydeter- miningdrillingfluidintrusion•[Core samples are analyzed for contentoftracersindrillingfluid]
Tracer test for perforation and fractures•Pinpointproducingwellsectionsby site-specifictraceradditiontostimu- lationfluids•Analysisofproducedfluidsreveals which part of the well was the source ofthefluids
t = 15 h
t = 13 h
t=0h:Injection
t = 2 h
t = 5 h
t = 9 h
t = 18 h: Detection, analysis and results