73
All the tools required for Temperature calibrated Live image processing WELCOME!

All the tools required for Temperature calibrated Live image processing WELCOME!

Embed Size (px)

Citation preview

Page 1: All the tools required for Temperature calibrated Live image processing WELCOME!

All the tools required for Temperature calibrated Live image processing

WELCOME!

Page 2: All the tools required for Temperature calibrated Live image processing WELCOME!

2

ThermoSoft II

Some of the images in this Slide Show were taken by the IRRIS 160.

This Slide Show can only present highlights – call us if you need some points clarified.

The illustration in this Slide Show are intended to be illustrations only – your actual applications may be different. This software has the flexibility, without being overly complex or difficult to learn, to handle many different applications.

Page 3: All the tools required for Temperature calibrated Live image processing WELCOME!

3

ThermoSoft II - Basic information

This is REAL TIME software. What this means is that the image displayed on the computer screen represents Infrared Events as they happen.

There are two specifications that INFLUENCE REAL TIME displays. The actual rate at which the camera can capture data internally. Frames per second

This software is takes temperature calibration information from the camera RS 232 port in REAL TIME – including RANGE information –

This is a capability and which distinguishes ThermoSoft II from other software that also works with the IRRIS camera.

Page 4: All the tools required for Temperature calibrated Live image processing WELCOME!

4

ThermoSoft – User friendly features

FAST SAVE – objects placed on the image, are saved and then used again in exactly the same position on the next image. This means you do not have to repeatedly enter temperature tools.

CLIP Board – ThermoSoft II supports Windows Clipboard for cut and paste into other Windows programs for fast reports.

Excel – data is saved to an Excel Log and can assume the shape of the object with all the temperature points of that object mapped.

Preferences - to setup the software the way you want it.

Commonality – editing, placing of objects, mouse actions, ONCE LEARNED are LEARNED for all.

Right Click – speed menus related to selected object.

Page 5: All the tools required for Temperature calibrated Live image processing WELCOME!

5

ThermoSoft II Highlights

REAL TIME - Analyze images frame by frame in real time.

RATIOMETRIC - Continuous image temperature calibration.

FILES – JPEG, TIFF, AVIO, BMP, TS2, THM, and EIC.

EVENT FILES – Fast Save, Movie Save, Log, Alarm, I/O.

CAMERAS – Almost anyone that works with the EDT Capture Card.

INFRARED REMOTE – LINE OF SIGHT Infrared Camera Control which permits the operator to capture images without using the keyboard from a distance, and through safety windows.

Camera Ranges. Camera control function which allows the operator to set a camera range from the software.

Page 6: All the tools required for Temperature calibrated Live image processing WELCOME!

6

ThermoSoft II - Modules

The next slide is a drawing of the modules available in ThermoSoft II.

This demonstrates the relationship and the integration of all the needed modules for a real time Infrared Software package.

EIC has the ability to create custom software packages by using any combination of these modules.

The great number of modules along with functions represent a real value to the customer.

Page 7: All the tools required for Temperature calibrated Live image processing WELCOME!

7

ThermoSoft II Block DiagramThermoSoft II Block Diagram

Page 8: All the tools required for Temperature calibrated Live image processing WELCOME!

8

ThermoSoft II – modules easy use features

The slide show has made the next slide into a index.

Click on any of the buttons to go to the FIRST PAGE of the module – so be sure to use the Page Down to move through all the pages.

To GO BACK – CLICK on the special ICON at the bottom of the page.

Page 9: All the tools required for Temperature calibrated Live image processing WELCOME!

9

ThermoSoft II - modules

Report/TemplatesDATA LINKINGFieldsImage placement

Save work •JPEG, BMP, files.•Or save the same.•Load , TIFF

Event Manager

Log DataFast SaveStreaming SaveI/O

Graphing •Live •scrolling•Static

Live WindowCapture Images

View LIVE DATA

Replay Editor

Infrared

Movies

Annotate with

•Text

•Shapes.

•Take temperature

Image Subtraction

•Show similarity•Show difference Between two files

Post Image AnalysisWith Image Editor• Zoom• Annotate•Take temperature

Page 10: All the tools required for Temperature calibrated Live image processing WELCOME!

10

Software Features – Open construction

Modular software with. Live window. Image editor. Graphing. Reporting.

Open Software construction. Place all of the modules on the screen at one time and move around them with a mouse CLICK.

See the next slide.

Page 11: All the tools required for Temperature calibrated Live image processing WELCOME!

11

Thermo-Soft II – Open construction

ThermoSoft II

Working screen.

In this case a live image, captured image, graph, and tool bars are displayed. Access any of these with a mouse CLICK

Page 12: All the tools required for Temperature calibrated Live image processing WELCOME!

12

Software Features continued

32 bit software Windows software for fast real time image analysis

NT 4.0 or Windows 2000 operating system.

12 bit digital IR Data for the highest possible camera resolution.

Real-time temperature calibration of images taken from Camera automatically.

Page 13: All the tools required for Temperature calibrated Live image processing WELCOME!

13

ThermoSoft II - Adjustments

Emissivity adjustment for: ROI – region of interest – drawn with a

mouse on a live or captured image. Adjust emissivity for the entire image. Adjustments from a standard table. Or edit to the user requirements.

Page 14: All the tools required for Temperature calibrated Live image processing WELCOME!

14

ThermoSoft II - Adjustments

Temperature adjustment for: ROI. For Entire image. Adjust emissivity for all the measurement tools. For example the user can adjust for each tool, or if there are

multiple instances of the same tool on the image, each one of these can have a different adjustment.

IR transmission factor adjustments Use to compensate for distance, dust, moisture, and other

conditions that reduce the amount of IR getting to the camera.

Page 15: All the tools required for Temperature calibrated Live image processing WELCOME!

15

Replay editor, color bar, and level sensitivity tool. Drag and drop positioning anywhere on the

screen. Perform direct operations on images to

save time for capture, text, and temperature tools. .

Special toolbars such as COLOR, and Level Set.

Information tool bars for the camera.

Page 16: All the tools required for Temperature calibrated Live image processing WELCOME!

16

ThermoSoft II – Tool Bars

Right CLICK the Mouse on any empty tool bar space to bring up the menu shown to the left.

Select from this the tool bar desired.

Tool bars can be selected individually for each module in the software.

Page 17: All the tools required for Temperature calibrated Live image processing WELCOME!

17

Software Features Continued

Apply a color palette to any image.

Palettes included Common palettes such as IRONBOW, GRAY,

and RAINBOW are included.

Make new palettes by using an editor.

Use the color bar tool shown to the left to show the relationship between color and temperature.

The ThermoSoft color bar is the method of creating ISOTHERMS.

Page 18: All the tools required for Temperature calibrated Live image processing WELCOME!

18

ThermoSoft - Features ISOTHERMS

Isotherms. Create isotherms by CLICKING on color bar. There is no limit on the number of isotherms applied

to an image. Use windows or the palette colors. Each ISOTHERM is fully editable. See editing slide.

CLICK on an area of the color bar to access an ISOTHERM.

Then EDIT the ISOTHERM by dragging and dropping on edges of ISOTHERM located on the COLOR BAR.

Page 19: All the tools required for Temperature calibrated Live image processing WELCOME!

19

Software Features - Isotherms

Zoomed image with two isotherms

Page 20: All the tools required for Temperature calibrated Live image processing WELCOME!

20

ThermoSoft Features - Annotate Images

Annotate Images Overlay text on an image. Overlay arrows, lines, boxes, circles, shapes on an

image. Change annotations with a edit. Drag and drop with a mouse to new locations. Save ALL the annotations with image. Reload with image and remove. The next

slide provides examples

Page 21: All the tools required for Temperature calibrated Live image processing WELCOME!

21

Annotate continued

Use

•Circles

•Squares,

•Shapes

To mark up images for reports and studies.

Use text over-laid on the image to illustrate and explain.

All of these examples are editable in the same way. And Can be removed from the image.

Page 22: All the tools required for Temperature calibrated Live image processing WELCOME!

22

Software Features Temperature Tools

Extract temperature with: Point Spot Line Rectangle Shape, Circle/Ellipse.

In Live or Image Edit Modules

Automatically temperature date to Reports

Page 23: All the tools required for Temperature calibrated Live image processing WELCOME!

23

Software Features – temperature tools

Temperature Tools

•Rectangle

•Line

•Spot

•Shape

•Circle

•Point

Page 24: All the tools required for Temperature calibrated Live image processing WELCOME!

24

Software Features – temperature tools

Page 25: All the tools required for Temperature calibrated Live image processing WELCOME!

25

Software Features continued

Level/Sensitivity Tool Use Buttons for small changes. Drag the entire tool to display a new

temperature SPAN Camera Range USE on LIVE, CAPTURED, or

ZOOMED images. Drag and drop to adjust a temperature

span.

Page 26: All the tools required for Temperature calibrated Live image processing WELCOME!

26

Software Features – Editing objects

Editing

The software edits EVERY object placed on the screen in the same way.

Once learned and with a little practice the process is the same for all objects.

Objects are text, temperature tools, isotherms, annotations, etc placed on the screen.

You can undo objects individually, or clear all of them from the screen

Page 27: All the tools required for Temperature calibrated Live image processing WELCOME!

27

Software Features – Objects

Object placement on the screen.

Every object edits in the same way.

Geometric objects such as rectangle, circles, shapes, have vertical dimensions.

For example an object placed on another object will affect that object, by being behind or in front of the object.

This is an infrequently used property, but it has uses, like observing the interaction of temperature tools.

Page 28: All the tools required for Temperature calibrated Live image processing WELCOME!

28

ThermoSoft Features – Exclusion Objects

A special group of objects have a special function to mask everything in the image when placed on them.

This means temperature, black pixels from the camera, or objects in the screen that you do not want to measure can effectively be removed.

THEY ARE NOT ERASED – and once the Exclusion object is removed they become visible or active.

These objects are edited like any object.

Page 29: All the tools required for Temperature calibrated Live image processing WELCOME!

29

ThermoSoft II – Exclusion Ojbects

Exclusion objects

Shape

Circles

Page 30: All the tools required for Temperature calibrated Live image processing WELCOME!

30

ThermoSoft features – Level/Set Tool

Objects with a temperature of 109 to 85 F are displayed.

By using the level/Set Tool.

Page 31: All the tools required for Temperature calibrated Live image processing WELCOME!

31

ThermoSoft Features – Level/Set tool

Objects with a temperature of 102 to 139 F are displayed.

Page 32: All the tools required for Temperature calibrated Live image processing WELCOME!

32

ThermoSoft Features - Remote

Provides camera and software controls.

To computer serial port.

Operating distance > 24 feet.

Pointing tolerance to receiver +/- 30 degrees.

The remote is an infrared device, with unique codes

that prevent interference with other like devices.

Page 33: All the tools required for Temperature calibrated Live image processing WELCOME!

33

ThermoSoft Features - Remote

Gather LIVE data with a CLICK of the remote.

Page 34: All the tools required for Temperature calibrated Live image processing WELCOME!

34

ThermoSoft Features - Remote

Control the software. Set palettes. Adjust level/sensitivity. Apply image subtraction. Freeze and capture images. Control the mouse pointer. Capture live images.

Page 35: All the tools required for Temperature calibrated Live image processing WELCOME!

35

ThermoSoft Features - Remote

Control the Camera Set Brightness and Gain Control FOCUS, and FOV Set units Set Range

Page 36: All the tools required for Temperature calibrated Live image processing WELCOME!

36

ThermoSoft Features - Remote

Setup Events so that

CLICKING button 2

causes a save.

Use any button 0 through 9 remotely.

Page 37: All the tools required for Temperature calibrated Live image processing WELCOME!

37

Live Window Features

ROI (region of interest). Drag and drop a rectangle on an image. Name or label the ROI for reference and use. A ROI can be used to: adjust emissivity, and temperature.

Apply included palettes.

Apply isotherms.

Use level/sensitivity toolbar to display temperature regions.

Page 38: All the tools required for Temperature calibrated Live image processing WELCOME!

38

Replay Editor (Movie Save)

View a ROI (region of interest) or the entire screen – frame by frame.

Page 39: All the tools required for Temperature calibrated Live image processing WELCOME!

39

Back one frame per CLICK

Rewind the the frames to the beginning.

Play frames backwards to beginning

STOP

Slow PLAY forward.

Play frames forwards

Rewind to the end.

Forward one frame per CLICK

Edit the speed of slow play.

Edit – save individual frames

Mark frames for deletion.

Remove marked frames.

Replay Toolbar

Use the Replay Toolbar to control the viewing of frames in the Movie Screen.

Page 40: All the tools required for Temperature calibrated Live image processing WELCOME!

40

-

Control all aspects of viewing a series of frames displayed in the MOVIE SCREEN with the Replay Toolbar.

The MOVIE SCREEN is a Windows screen with all the windows functionality.

Perform any ThermoSoft Editing function as YOU VIEW the movie screen.

In the example to the right - a line graph is displayed and extracts temperature information as the frames are displayed frame by frame.

Select individual frames and save them to all the supported files of ThermoSoft II.

And much more . . .

Frame Counter showing the 124th frame of 278 frame, and POINTER

Replay Toolbar – viewing an IR movie

Page 41: All the tools required for Temperature calibrated Live image processing WELCOME!

41

Subtract a new image from a saved image.

Show similarity by temperature.

Show differences by temperature.

Display only the results.

Any archived file including FAST SAVE can be used as a comparison file for image subtraction

Image Subtraction

Page 42: All the tools required for Temperature calibrated Live image processing WELCOME!

42

Image Subtraction continued

Image 1 DifferenceImage 2

- =

Page 43: All the tools required for Temperature calibrated Live image processing WELCOME!

43

Then analyze, print, report, the results.

Image Subtraction continued

Page 44: All the tools required for Temperature calibrated Live image processing WELCOME!

44

Image Editor module

Analyze captured or saved images. Point, Spot, Line, Circle, Rectangle, Shape. Zoom images. Annotate. Adjust temperature, and emissivity. Print Images.

Page 45: All the tools required for Temperature calibrated Live image processing WELCOME!

45

Image Editor continued

Zoom on an image and: Colorize Set temperature range Apply ISOTHERMS Print the zoomed area. Place in a report. Graph Cut and paste. Archive

Page 46: All the tools required for Temperature calibrated Live image processing WELCOME!

46

Graphing

Graph LINE temperature data from LIVE or CAPTURED images.

Graphing types.

Graph as many line temperatures as desires.

Page 47: All the tools required for Temperature calibrated Live image processing WELCOME!

47

Graphing Continued

To use – select line objects.

Graphs can be saved, to CLIPBOARD, printed, or linked into a report.

DATA BARS.

Page 48: All the tools required for Temperature calibrated Live image processing WELCOME!

48

Graphing Continued

Customize graph

Page 49: All the tools required for Temperature calibrated Live image processing WELCOME!

49

The event manager sets up a temperature reporting session. User friendly set up, without hardware complexity. Events can be saved for reuse. Flexibility in reporting temperate data. Trigger events from software, temperature, or external

devices. Link temperature data from live images to hardware data

collecting devices.

Event Manager

Page 50: All the tools required for Temperature calibrated Live image processing WELCOME!

50

Event Manager continued

Setup Screen

Page 51: All the tools required for Temperature calibrated Live image processing WELCOME!

51

Event Manager Continued

Add Object Temperature

Select persistent conditions or Momentary for an event trigger

Page 52: All the tools required for Temperature calibrated Live image processing WELCOME!

52

Event Manager continued

Responses to continuous trigger (switch closure) conditions TTL Outputs Analog Outputs – 2 to 20 ma or scaled voltage. Repeatedly save temperature data in individual files. Repeatedly log

Page 53: All the tools required for Temperature calibrated Live image processing WELCOME!

53

Event Manager continued

Response to momentary triggered conditions. Save Image. Log Data. Log data to a delimited file for each trigger. Start repeated save End repeated save – terminate a begun Start repeated log. End repeated log. Display alarms. Initiate IR movie save. Instant save. Saves an image but formats images in the

sequential save format which a has numbered sequence.

Page 54: All the tools required for Temperature calibrated Live image processing WELCOME!

54

DATA I/0

National I/0 computer Card 8 TTL I/O lines for starting stopping events and voltage

outputs. 10 DA output lines – voltage or current outputs.

12 bit output .015 % FSR accuracyCurrent – 4 to 20 maVoltage – 0 10 volts or +/- 10 volts.

ISA card.

Page 55: All the tools required for Temperature calibrated Live image processing WELCOME!

55

Report Editor

Template based with: Grids Rich text – place anywhere Image placement Automatic data and image linking. Graphics insertion. Fields such as date, time, calculation, etc.

Page 56: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

Page 57: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

Page 58: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

Page 59: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

Page 60: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

Page 61: All the tools required for Temperature calibrated Live image processing WELCOME!

Go BackGo Back Go Forward

An infrared image of a 5 cent coin illustrates the details captured by the software and an IRRIS camera

Page 62: All the tools required for Temperature calibrated Live image processing WELCOME!

62

Testing vehicle tires

Tires are run on a dynamometer with controlled speed and load to simulate vehicle use.

FS mirror used used to show tread temperature.

Images obtained with IRRIS 160 ST camera, capable of >80 frame PS.

Page 63: All the tools required for Temperature calibrated Live image processing WELCOME!

63

Testing tires continued

Tread temperature and signature was also obtained.

Temperature data taken from live images during test and automatically saved periodically.

Tires were run a period of time lasting hours.

Page 64: All the tools required for Temperature calibrated Live image processing WELCOME!

64

Testing tires continue

Shape temperature is used to outline the tire. Exclusion objects remove areas not wanted in measurement.

Circle temperature was used to get tread temperature.

Page 65: All the tools required for Temperature calibrated Live image processing WELCOME!

Testing tires #1

Go BackGo Back Go Forward

Page 66: All the tools required for Temperature calibrated Live image processing WELCOME!

Testing tires #2

Go BackGo Back Go Forward

Page 67: All the tools required for Temperature calibrated Live image processing WELCOME!

Testing tires #3

Go BackGo Back Go Forward

Page 68: All the tools required for Temperature calibrated Live image processing WELCOME!

68

The Software Package

Software with all necessary drivers.

PCI Capture board with cable.

IR remote with receiver.

Sample images, reports, and online help.

Getting started manual.

Illustrated indexed user manual

Everything you need is included.

Page 69: All the tools required for Temperature calibrated Live image processing WELCOME!

69

Easy 2 step software installation.

Install the capture board.

Install the software.

Page 70: All the tools required for Temperature calibrated Live image processing WELCOME!

70

Printer Support

Supports network printers.

Supports windows printers.

Print single images, reports, templates, or graphs .

Page 71: All the tools required for Temperature calibrated Live image processing WELCOME!

71

Support

Software is supported by knowledgeable people who understand infrared applications.

Free software support. No cost software upgrades. Training at your plant location or EIC.

Page 72: All the tools required for Temperature calibrated Live image processing WELCOME!

72

About EIC

EIC is an independent software company located at 120 Old M-21, Jenison, MI 49428 United States

To contact us: Phone 616 457 7155 Email [email protected] Web www.thermorx.com or www.eic-inc.com

We reserve all rights to this slide show. If you want to reproduce anything for any use contact EIC .

Page 73: All the tools required for Temperature calibrated Live image processing WELCOME!

73

The END

We hope this exploration of ThermoSoft II has been helpful.

Need a demo, more information – turn the page and contact us.