21
All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration. Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquayup.com. ©2012 McQuay International www.mcquayup.com

All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

  • Upload
    others

  • View
    21

  • Download
    0

Embed Size (px)

Citation preview

Page 1: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

All Product Catalogue AP-MDS-12

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.For the most up-to-date product information, please go to www.mcquayup.com.

©2012 McQuay International www.mcquayup.com

Page 2: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

Manufacturing Plant

Cramlington

Cecchina

Kuala Lumpur

Jakarta

SuzhouWuhan

Shenzhen

Multi Digital ScrollSystem Features 4Application 12Outdoor Features 14Indoor Features 16Integrated Software 23Controller And Accessories 24Project References 25

SpecificationsR-22 Outdoor R-22 - 1R-22 Indoor R-22 - 3R-410A Outdoor R-410A - 1R-410A Indoor R-410A - 4

Minneapolis

Faribault

OwatonnaStauntan

Mexico City

Auburn

Africa• Ghana • Kenya • Madagascar • Mauritius • Morocco • Nigeria • South Africa • Sudan • Tanzania • Tunisia • Uganda

Americas• Argentina • Chile • Guadeloupe • Mexico • Paraguay • Puerto Rico • Uruguay

Asia• Cambodia • China • Hong Kong • Indonesia • Maldives • Myanmar• Nepal • Pakistan • Philippines • Singapore

Europe• Albania • Belgium • Croatia • Cyprus • Czech Republic • Greece• Hungary • Italy • Lithuania • Malta • Poland • Portugal• Russia • Serbia • Spain • Turkey • United Kingdom

Middle East• Azerbaijan • Bahrain • Iran • Jordan • Lebanon • Oman • Qatar • Syria • United Arab Emirates

Oceania• Fiji

Page 3: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

5MDS 080/100/120/140/160/180BR

5MDS 050/060/070B/BR

25.0 - 47.0 28.0 - 53.0

5MDS 380/400/420BR

5MDS 200/220/240/260/280/300/320/340/360BR 53.0 - 94.0

102.0 - 111.0

59.0 - 106.0

113.0 - 124.0

5MDS 440/460/480/500BR 117.0 - 134.0 130.0 - 148.0

Model RangeCooling

Capacity (kW)Heating

Capacity (kW)

Model RangeCooling

Capacity (kW)Heating

Capacity (kW)

8.5 - 18.5

MDS 080/100/120/150B/BR

MDS 180/200/220/240/260/280/300/320B/BR

24.5 – 40.0

9.0 - 20.0

13.5 – 19.0 15.0 – 21.0

26.0 – 43.0

47.5 – 85.0 50.0 – 92.0

MDS 030/040/050/060/070A/AR

Split Type IndoorModel Range Cooling

Capacity (kW)Heating

Capacity (kW)R-410AR-22

MWMD-G2

MCKD-A

MCKD-C

MCMD-E

MCMD-D

MCCD-C

MDBD

HORIZONTALDISCHARGE

VERTICALDISCHARGE

VERTICALDISCHARGE

HORIZONTAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

2.5 - 6.5

5.6 - 14.0

2.8 - 5.6

3.6 - 8.0

11.2 - 16.4

2.8 - 7.4

6.3 - 16.0

3.2 - 6.3

4.0 - 9.0

2.8 - 16.4 3.2 - 18.5

22.4 – 28.0 25.0 – 31.5

2 3

MDS R-410A Condensing Unit

MDS R-22 Condensing Unit

12.5 - 18.5

Page 4: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

MORE ECONOMICAL OPERATIONWith higher IPLV, MDS is able to operate with lower power consumption.

4

NO CONVERSION LOSTComparing to the traditional inverter drive air-conditioner, MDS has eliminated the possibility of lost of energy during the conversion of power signal.

BETTER DEHUMIDIFYING PERFORMANCEThe continuously operating compressor in the MDS system provides better dehumidifying performance, and hence able to reduce the indoor RH to a more desired level. With lower RH in the interior, the growth of the bacteria and fungus are inhabited.

BETTER PART LOAD EFFICIENCYMost air-conditioning system operates in the 30%~70% region. Integrated with the digital scroll compressor technology, MDS is capable to modulate its supply capacity to meet most indoors requirement closely. This modulating capability enable the MDS system to offer higher IPLV (Integrated Part Load Value).

Utilising the digital scroll compressor technology, the McQuay Multi Digital ScrollSystem (MDS) is seen as the next generation products for high-efficiency air conditioning.

AC Converted FrequencyInverter

Compressor

Capacity Controller

TransformationConcumption = 0%

MotorConsumption

= 5-10%

DCAC DCTransformer

AC DCFrequency Conversion

T rad i t i ona l I n ve r t e r Sys tem

DigitalCompressorAC PWM valve

Capacity Controller

TransformationComsumption = 0%

MDS Sys tem

5th

7th

11th

13th

17th

19th

0 1 2 3 4 5

MDS System EMC Standard Inverter System

EMC comparison during development stage

Temp.

Time1 2 3 4

Tr

Ts

The temperature fluctuation range of traditional air conditioning system

The temperature fluctuation range of MDS system

Tr = Room TemperatureTs = Set Temperature

5

MDS 100B System

100%

5%

FixedCompressorOperating

DigitalOperating

DigitalOperating

Loading Unloading

MDS100BR IPLV Testing

2

2.5

3

3.5

4

4.5

0 20 40 60 80 100

IPLV(C) = 3.56

IPLV(H) = 3.71

Capacity (%)

Cooling

Heating

COP (W/W)

IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoorand 27°C DB outdoorHeating cycle:20°C DB / 15°C WB indoorand 7°C DB / 6°C WB outdoor

IMPROVED ELECTROMAGNETIC COMPATIBILITYUnlike variable speed compressors air conditioners, MDS runs at a constant speed throughout the operation, thus there is lower electromagnetic interference. This unique feature reduces the need for expensive electromagnetic suppression electronics required to ensure electromagnetic compatibility.

TIGHTER TEMPERATURE CONTROLThe ambient of the outdoor and indoor change frequently and this will affect the indoor cooling and heating load. With MDS system, using an improved control algorithm, the temperature is kept closer to the set temperature.

Page 5: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

6 7

Comparing to conventional chilled water system, MDS required lesser equipment. Boilers, cooling tower are things in the past with MDS. Thus, MDS is a better solution for new projects or even retrofit purposes.

Conventional ChilledWater System

MDS System

PERFORMANCE CHOICESOLUTIONS

Temperature °C

43°CDB

0°CDB

16°CWB

-15°CWDB

50

40

30

20

10

0

-10

-20

Cooling Cycle Heating Cycle

WIDER OPERATING RANGEMDS system undergo rigorous test to ensure that the system can operate within -15ºC to 43ºC.

INTELLIGENT CAPACITY MODULATIONThe MDS system operates in a stepless capacity modulation ranging from 10~100%. The modulation will closely match the demand capacity whereby contributing higher IPLV.

t1 t2Time

InitialTemperature

SettingTemperature

Traditional Air ConditioningMDS System

RAPID COOLING AND HEATING CAPABILITYThe improved heat-exchanger combining with the better efficiency compressor promotes rapid exchange between refrigerant and air, ensuring set temperature to be achieved faster compared to traditional air-conditioning system.

Height15m

PipingLength150m

Height50m

LONG PIPING DESIGN FOR FLEXIBILITYPiping length between outdoor and indoor unit can be extended up to 150 meters. The height between outdoor unit and indoor unit can be extended up to 50 meters. The height difference between indoor units can be as high as 15 meters. This greatly reduces constraint and offers more flexibility in system design.

The refnet joint is provided by the factory in accordance with different indoor units, which will reduce the work force at site.

Only a common 2-core, screen cable wire is required to enable communication between outdoor and indoors.

EASIER INSTALLATIONIn-house designed piping joints and wiring connection make it possible to install MDS system faster and easier.

BETTER PLACE UTILISATIONMDS uses the single outdoor multiple indoors combination. This concept has greatly reduced outdoor units and enhances flexibility during installation.

Page 6: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

VARIETY OF INDOORSThe MDS indoors come with a variety of design and capacity which can be selected to suit most air conditioning needs.

8 9

ADAPTS EASIER TO ANY FLOOR PLANThe wide indoor models can meet the needs of building size and interior design easier. Incorporate with the flexible piping design, the MDS system is suitable for most type of floor layout and various applications.

ALARM AND DIAGNOSIS SYSTEMThe MDS system is built in with an alarm system, alerting owners or users for abnormal operation.A user-friendly diagnosis system helps to identify the problems, ensuring continuous operation of the MDS system.

AUTOAUTO

Page 7: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

10 11

AUTO-RANDOM RESTARTAfter power failure, the MDS system will automatically restart operation base on the last state memory. Setting of the unit will not be lost, thus eliminating the needs for re-programming.

CENTRAL CONTROL SYSTEMThe MDS Smart Commander is designed with user-friendly interface, enable simple monitoring and control of the system via a computer.

MDS-B series is capable to connect up to 38 units of indoors. Total indoor units capacity can range from 50% to 120% of the outdoor capacity.

LARGE CAPACITY

Page 8: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

With all these advantages, it is very clear that MDS is a better solution for centralised air-conditioning system. What would be the consideration factor to select MDS? Here are some of the main consideration factors and examples.

HospitalConsideration:• Places that require low or no EMC interference • Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

OfficesConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Location for outdoor is limited• Centralized Control

Department Store / RestaurantConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

12 13

House / Apartment / CondominiumConsideration:• Location for outdoor is limited.• Various type of indoor unit with separate temperature requirement.• Heat load of the same air-conditioned area varies

Exhibition / Concert HallConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

Factor 1Location for outdooris limited. MDS can be used due to the ability to couple multiple indoors with only 1 outdoor. Better space utilization.

Factor 2Various type of indoor unit with separate temperature requirementMDS system can be couple with various type of indoors. Each indoor can be design to supply to a specific area only and the temperature setting is base on individual indoor setting.

Factor 3Heat load of the same air-conditioned area variesMDS is able to match the indoor load requirement with its part loading capability.

Factor 5Places that require low or no EMC interferenceThe MDS modulation is control by mechanical parts. No change in power supply (frequency or current), thus lower electromagnetic interference.

Factor 4Centralized ControlMDS outdoors and indoors can be linked together and control using the MDS Smart Commander. The software can also perform scheduling of the indoor units base on the operating duration.

Page 9: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

RELIABLE TECHNOLOGYMDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly.

• MDS system has better oil return performance even at low capacities, which will make sure that all of the movable parts of the compressor can be lubricated and cooled down.

• It reduces the start/stop times, which will reduce the attack to the electricity supply net.

• The PWM (Pulse Width Modulation) valve has the longevity of 40 million times.

• The design is simple and there is no requirement for bypass valve.

SMALL FOOTPRINTThe outdoor unit of MDS system is designed as package, the structure occupies less space and is easier to move.

The brain of the MDS system is the compressor which is incorporated in the outdoor condensing unit.With this technology, the outdoor is constructed in a uniform and solid design and focusing on smaller footprint to provide better space utilisation.

UNIFORM DESIGNThe outdoor units can be located on the rooftop. The uniform outlook and dimension allows side by side installation.

QUIET OPERATIONThe condensing unit utilises an advanced spiral fan blades. The smooth material and fan blade design help to reduce the turbulent flow and thus reduce the air flow noise.

14 15

Page 10: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and
Page 11: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

CKCeiling CassetteA Series & C SeriesMCKD 010/015/020 CMCKD 020/025/030/040/050 AM5CKD 010/015/020 CM5CKD 020/025/030/040/050 ACooling 9,600 Btu/h – 47,800 Btu/h 2.8 kW – 14.0 kWHeating 10,900 Btu/h – 54,600 Btu/h 3.2 kW – 16.0 kW

STYLISH AND SLIM PANELThe slim panel can be blended easily into most interior decoration and design.

700mm

CEILING AND FLOOR INSTALLATION OPTIONThe MCMD is designed with the option to install either below the ceiling or mounted at low wall position to suit most interior design requirement.

4 WAY AIR DISCHARGE AND AIR SWINGIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.

CCCeiling ConvertibleE SeriesMCMD 020/025/028 EM5CMD 015/020/025/028 ECooling 12,300 Btu/h - 27,300 Btu/h 3.6 kW - 8.0 kWHeating 13,600 Btu/h - 30,700 Btu/h 4.0 kW - 9.0 kW

700mm

BUILT-IN HIGH HEAD DRAIN PUMPThe unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.

FLEXIBLE INSTALLATION The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.

18 19

BETTER SERVICEABILITYThe washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access. • Fan Motor• Blower• Wiring Connection• Control Box• Piping Connection

Wall bracket supplied as optional item

GS01

GS01

Page 12: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

CMCeiling ConvertibleD SeriesMCMD 040/050 DMCMD 062 CM5CMD 040/050 DM5CMD 062 CCooling 38,200 Btu/h – 56,000 Btu/h 11.2 kW – 16.4 kWHeating 42,700 Btu/h – 63,100 Btu/h 12.5 kW – 18.5 kW

Ceiling ConcealedC SeriesMCCD 010/015/020/025/030/040/050/060 CM5CCD 010/015/020/025/028/030/038/040/050/060 CCooling 9,600 Btu/h – 56,000 Btu/h 2.8 kW – 16.4 kWHeating 10,900 Btu/h – 63,100 Btu/h 3.2 kW – 18.5 kW

CC

TWO WAY AIR DISCHARGE

Equipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.

AUTOMATIC AIR SWING *

The swing mode enables the air flow to be evenly distributed into the room from the front discharge area.* Applicable for M(5)CMD 040/050D only.

CEILING AND FLOOR INSTALLING OPTION *

The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit most interior design requirements.* Applicable for M(5)CMD 040/050D only.

DOUBLE PROTECTION DRAINAGE SYSTEM

The primary drain pan is designed with higher thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.

Primary Drain PanPolysterene (Ps) With Height Impact Polystyrene (Hips) Cover

Secondary Drain Pan With Insulation

FLEXIBILITY IN SYSTEM DESIGN

The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system.

20 21

GS01 MC301

Page 13: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

ICE CREAM

ICE CREAM

COMPLETE MODELTo ease installation, this model has the Electronic Expansion Valve (EXV) built into the unit. User do not need to worry about the noise from the EXV as it is properly insulated.

DBDucted BlowerMDBD 080 / 100Cooling 76,400 Btu/h – 95,500 Btu/h 22.4 kW – 28.0 kWHeating 85,300 Btu/h – 107,500 Btu/h 25.0 kW – 31.5 kW

MDS SMART COMMANDERFor central monitoring and control purposes, the MDS offers a real time system. This software is the system to human interface, allowing users or owners to monitor and to control the MDS system. With this software, user or owners is able to ;• Monitor & control any MDS indoor & outdoor unit • Alarming alert• Zoning & grouping capabilities • Scheduling option

BETTER AIR DISTRIBUTION FOR COMFORTABLE LIVINGThe conditioned air can be effectively distributed to the room through ducting.

EXTENDED INDOOR MODELThe ducted blower is designed to cater higher indoor capacity required. Combining ceiling concealed and ducted blower, the MDS system is able to fulfill ducted application with capacity range from 2.8kW to 28.0kW

As a system provider, McQuay MDS system is equipped together with a collection of customized software to provide system design & selection and individual units control & monitoring.

22 23

SELECTION SOFTWAREThis software is incorporated with data on indoor models. This allow the designers to choose the appropriate indoors model to suit they needs. Besides that, this software will determine the required quantity of refnet joints, pipes and other accessories base on the design. With this software, most designs can be completed with just a few simple clicks.

MC301

Page 14: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

CENTRAL CONTROLLER MC303Optional Item. To provide group or individual control to indoors (Up to 32 indoors). Basic control such as ON/OFF, mode setting, temperature setting and others.

Standard Controller

Optional Controllerand Accessories

PC CONTROLMDS Smart Commander act as the system to human interface. A communication gateway is inclusive for the wiring connection.

WIRED CONTROLLER MC301Standard wired controller for MCCD-C. Basic control such as ON/OFF, mode setting, temperature setting and others.

WIRELESS GS01Standard wireless handset for wall mounted, ceiling cassette and ceiling convertible. Basic control such as ON/OFF, mode setting, temperature setting and others.

Commercial SectorCountry : ThailandIndoor Type : Ceiling Concealed

Commercial SectorCountry : ChinaIndoor Type : Ceiling Concealed Ceiling Convertible

Residential SectorCountry : QatarIndoor Type : Wall Mounted

Residential SectorCountry : IndonesiaIndoor Type : Ceiling Concealed

Commercial SectorCountry : SingaporeIndoor Type : Ceiling Concealed Ceiling Convertible Ceiling Cassette

Residential SectorCountry : SyriaIndoor Type : Ceiling Concealed

MDS systems has proven to be reliable and a system of choice.Many projects, whether government or privately own premises had chosen MDS as their comfort provider:

24 25

REFNET & DISTRIBUTORS JOINTPiping joint design for the MDS system. A total of 6 types of refnet joint is available for different piping combination.

Page 15: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-221

R-222

R-22 Outdoor SpecificationsMDS-A

MDS 030AR MDS 040AR MDS 050AR MDS 060AR MDS 070AR

Btu/h 29,002 34,120 42,650 49,474 61,400

W 8,500 10,000 13,000 <12,500> 14,500 <14,500> 18,500

Btu/h 30,708 39,238 46,062 56,298 68,200

W 9,000 11,500 14,000 <13,500> 16,500 <16,500> 20,000

COOLING W 3,000 3,500 4,400 <4,300> 5,000 <5,000> 5,800

HEATING W 2,500 3,400 4,200 <3,900> 4,200 <4,200> 5,000

MDS 030A MDS 040A MDS 050A MDS 060A MDS 070A

Btu/h 29,002 34,120 42,650 49,474 61,400

W 8,500 10,000 13,000 <12,500> 14,500 <14,500> 18,500

W 3,000 3,500 4,400 <4,300> 5,000 <5,000> 5,800

V/Ph/Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50<380-415 / 3 / 50>

220-240 / 1 / 50<380-415 / 3 / 50> 380-415/ 3/ 50

R-22 R-22 R-22 R-22 R-22

l/s / cfm 1056 / 2237 695 + 695 / 1470 + 1470 695 + 695 / 1470 + 1470 1055 + 1055 / 2230 + 2230 1111 + 1111 / 2354 + 2354

dB(A) 59 59 59 60 62

HEIGHT mm/in 900 / 35.4 1044 / 41.4 1044 / 41.4 1247 / 49.1 1349 / 53.1

WIDTH mm/in 840 / 33.1 1058 / 41.7 1058 / 41.7 1058 / 41.7 1058 / 41.7

DEPTH mm/in 408 / 16.1 430 / 16.9 430 / 16.9 430 / 16.9 430 / 16.9

kg/lb 82 / 181 112 / 247 117 / 258 123 / 271 135 / 298

kg/lb 85 / 187 115 / 254 120 / 265 130 / 287 145 / 320

TYPE (LIQUID/GAS) FLARE FLARE FLARE FLARE FLARE

LIQUID mm/in 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8

GAS mm/in 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 22.2 / 7/8

HEATPUMPUNIT WEIGHT

NOMINAL TOTAL INPUTPOWER - 1Ø <3Ø>

UNIT DIMENSION

POWER SOURCE - 1Ø <3Ø>

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

SOUND PRESSURE LEVEL

PIPECONNECTION SIZE

COOLING ONLY

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

AIR FLOW

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

MDS-B

MDS 080BR MDS 100BR MDS 120BR MDS 150BR

Btu/h 83,594 95,536 110,890 136,480

W 24,500 28,000 32,500 40,000

Btu/h 88,712 102,360 116,008 146,716

W 26,000 30,000 34,000 43,000

COOLING W 7,500 8,500 9,800 12,900

HEATING W 7,200 8,300 9,000 11,100

MDS 080B MDS 100B MDS 120B MDS 150B

Btu/h 83,594 95,536 110,890 136,480

W 24,500 28,000 32,500 40,000

W 7,500 8,500 9,800 12,900

V/Ph/Hz

R-22 R-22 R-22 R-22

HI-FAN l/s / cfm 3194 / 6768 3194 / 6768 3472 / 7357 3750 / 7945

LOW-FAN l/s / cfm 1528 / 3237 1528 / 3237 2083 / 4414 2222 / 4708

dB(A) 62 64 66 67

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 275 / 606 285 / 628 290 / 639 355 / 783

kg/lb 290 / 639 300 / 661 305 / 672 370 / 816

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 12.7 / 1/2 12.7 / 1/2 15.9 / 5/8 15.9 / 5/8

GAS mm/in 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 34.9 / 1 3/8

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

380-415 / 3 / 50

COOLING ONLY

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

OU

TD

OO

R U

NIT

HEATPUMPUNIT WEIGHT

MODEL

POWER SOURCE

PIPECONNECTION

TYPE (LIQUID/GAS)

SIZE

REFRIGERANT TYPE

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

MDS-B

MDS 180BR MDS 200BR MDS 220BR MDS 240BR

Btu/h 162,070 170,600 187,660 221,780

W 47,500 50,000 55,000 65,000

Btu/h 170,600 180,836 197,896 232,016

W 50,000 53,000 58,000 68,000

COOLING W 14,100 15,200 16,700 19,800

HEATING W 13,200 14,700 16,200 18,500

MDS 180B MDS 200B MDS 220B MDS 240B

Btu/h 162,070 170,600 187,660 221,780

W 47,500 50,000 55,000 65,000

W 14,100 15,200 16,700 19,800

V/Ph/Hz

R-22 R-22 R-22 R-22

HI-FAN l/s / cfm 3194 + 3194 / 6768 + 6768 3194 + 3194 / 6768 + 6768 3194 + 3194 / 6768 + 6768 3472 + 3472 / 7357 + 7357

LOW-FAN l/s / cfm 1528 + 1528 / 3237 + 3237 1528 + 1528 / 3237 + 3237 1528 + 1528 / 3237 + 3237 2083 + 2083 / 4414 + 4414

dB(A) 66 66 66 68

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 1990 / 78.3 1990 / 78.3 1990 / 78.3 1990 / 78.3

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 520 / 1146 560 / 1235 560 / 1235 570 / 1257

kg/lb 550 / 1213 590 / 1301 590 / 1301 600 / 1323

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 15.9 / 5/8 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4

GAS mm/in 34.9 / 1 3/8 34.9 / 1 3/8 38.1 / 1 1/2 38.1 / 1 1/2

380-415 / 3 / 50

TYPE (LIQUID/GAS)

SIZE

NOMINAL TOTAL INPUT POWER

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

PIPE CONNECTION

AIR FLOW

COOLING ONLY

HEATPUMPOU

TD

OO

R U

NIT

SOUND PRESSURE LEVEL

UNIT WEIGHT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

MDS-BMDS 260BR MDS 280BR MDS 300BR MDS 320B

MDS 120BRM + MDS 150BRS MDS 150BRM +MDS 130BRS MDS 150BRM + MDS 150BRS MDS 160BRM + MDS 160BRS

Btu/h 238,840 242,252 272,960 290,020

W 70,000 71,000 80,000 85,000

Btu/h 255,900 266,136 290,020 313,904

W 75,000 78,000 85,000 92,000

COOLING W 21,300 21,000 26,200 27,700

HEATING W 20,900 20,300 23,600 25,500

MDS 260B MDS 280B MDS 300B MDS 320B

MDS 120BM + MDS 150BS MDS 150BM + MDS 130BS MDS 150BM + MDS 150BS MDS 160BM + MDS 160BS

Btu/h 238,840 242,252 272,960 290,020

W 70,000 71,000 80,000 85,000

W 21,300 21,000 26,200 27,700

V/Ph/Hz

R-22 R-22 R-22 R-22

HI-FAN l/s / cfm 3472 + 3750 / 7357 + 7945 3750 + 3750 / 7945 + 7945 3750 + 3750 / 7945 + 7945 3750 + 3750 / 7945 + 7945

LOW-FAN l/s / cfm 2083 + 2222 / 4414 + 4708 2222 + 2222 / 4708 + 4708 2222 + 2222 / 4708 + 4708 2222 + 2222 / 4708 + 4708

dB(A) 68 69 69 69

HEIGHT mm/in 1840/72.4 1840/72.4 1840/72.4 1840/72.4

WIDTH mm/in 2280/89.8 2580/101.6 2580/101.6 2580/101.6

DEPTH mm/in 840/33.1 840/33.1 840/33.1 840/33.1

kg/lb 645 / 1422 710 / 1565 710 / 1565 720 / 1587

kg/lb 675 / 1488 740 / 1631 740 / 1631 750 / 1653

Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed

LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4

GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8

COOLING ONLY

HEATPUMP

380-415 / 3 / 50POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

SOUND PRESSURE LEVEL

UNIT DIMENSION

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

AIR FLOW

UNIT WEIGHT

MODELMASTER UNIT+SLAVE UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

Page 16: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-22 Indoor Specifications

R-223

R-224

MWMD-G

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

IND

OO

R U

NIT

UNIT WEIGHT

AIR FLOW

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

PIPE CONNECTION

TYPE

SIZE

MWMD 009G2 MWMD 010G2 MWMD 015G2 MWMD 020G2 MWMD 025G2

8500 9600 12300 19100 22200

2500 2800 3600 5600 6500

9600 10900 13600 21500 25200

2800 3200 4000 6300 7400

130 / 275 142 / 300 163 / 345 231 / 490 397 / 630

106 / 225 118 / 250 135 / 285 193 / 410 231 / 490

83 / 175 94 / 200 104 / 220 160 / 340 208 / 440

40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 43 / 40 / 35 49 / 44 / 42

304 / 12.0 304 / 12.0

799 / 31.5 1062 / 41.8 1062 / 41.8

222 / 8.7 222 / 8.7

10 / 22.0 16 / 35.3 16 / 35.3

9.5 / 3/8

12.7 / 1/2

899 / 35.4

12 / 26.5

220 - 240 / 1 / 50

R-22

EXV

260 / 10.2

198 / 7.8

FLARE VALVE

6.4 / 1/4

9.5 / 3/8 15.9 / 5/8

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / cfm

l/s / cfm

l/s / cfm

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

MCKD-C

PIPE CONNECTIONSIZE

AIR FLOW

REFRIGERANT TYPE

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT (UNIT + PANEL)

UNIT DIMENSION ( ) - WITH PANEL

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

IND

OO

R U

NIT

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

MCKD 020C

19100

5600

21500

6300

212 / 450

194 / 410

160 / 340

44 / 41 / 37

23 + 2 / 50.7 + 4.4

15.9 / 5/8

MCKD 015C

12300

3600

13600

4000

194 / 410

170 / 360

156 / 330

41 / 38 / 34

23 + 2 / 50.7 + 4.4

12.7 / 1/2

FLARE VALVE

6.4 / 1/4

570 (640) / 22.4 (25.2)

570 (640) / 22.4 (25.2)

250 (295) / 9.8 (11.6)

R-22

REFRIGERANT CONTROL (EXPANSION DEVICE) EXV

220 - 240 / 1 / 50

MCKD 010C

9600

2800

10900

3200

194 / 410

170 / 360

156 / 330

41 / 38 / 35

22 + 2 / 48.5 + 4.4

9.5 / 3/8

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

TYPE

MCMD-E

NOTE:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

POWER SOURCE

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

UNIT WEIGHT

UNIT DIMENSION

PIPE CONNECTION 9.5 / 3/8

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

IND

OO

R U

NIT

MCMD 028E

27300

8000

30700

9000

302 / 640

264 / 560

217 / 460

51 / 48 / 47

28 / 61.7

MCMD 025E

22200

6500

25200

7400

274 / 580

250 / 530

231 / 490

50 / 47 / 46

220 - 240 / 1 / 50

R-22

EXV

FLARE VALVE

15.9 / 5/8

218 / 8.6

1080 / 42.5

630 / 24.8

27 / 59.5

MCMD 020E

19100

5600

21500

6300

245 / 520

217 / 460

192 / 406

48 / 46 / 43

6.4 / 1/4

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

TYPE

SIZELIQUID

GAS

MCKD-A

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151(NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4a) M5CKD020-025A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.4b) M5CKD030-040A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

PIPE CONNECTION

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

UNIT DIMENSION( ) - WITH PANELINDOOR UNIT

UNIT WEIGHT (UNIT + PANEL)

MODEL INDOOR UNIT

POWER SOURCE

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

MCKD 020A MCKD 025A MCKD 030A MCKD 040A MCKD 050A

19100 22200 30700 38200 47800

5600 6500 9000 11200 14000

21500 25200 34100 42700 54600

6300 7400 10000 12500 16000

220 - 240 / 1 / 50

349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040

297 / 630 311 / 660 349 / 740 406 / 860 448 / 950

283 / 600 283 / 600 321 / 680 359 / 760 411 / 870

42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50

31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8

6.4 / 1/4

FLARE VALVE

9.5 / 3/8

15.9 / 5/8 19.1 / 3/4

820 (930) / 32.2 (36.6)

R-22

EXV

335 (378) / 13.2 (14.9)

820 (930) / 32.2 (36.6)

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

TYPE

SIZE

HEIGHT

WIDTH

HIGH

DEPTH

MEDIUM

LOW

LIQUID

GAS

Page 17: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-225

R-226

LIQUID

GAS

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

WIDTH

DEPTH

UNIT WEIGHT

UNIT DIMENSION

HEIGHT

HIGH

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

LOW

MEDIUM

IND

OO

R U

NIT

POWER SOURCE

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

PIPE CONNECTION

TYPE

SIZE

MCMD-D/C

MCMD 040D MCMD 050D MCMD 062C

Btu/h 38200 47800 56000

W 11200 14000 16400

Btu/h 42700 54600 63100

W 12500 16000 18500

V/Ph/Hz

l/s / CFM 477 / 1010 491 / 1040 732 / 1550

l/s / CFM 420 / 890 448 / 950 623 / 1320

l/s / CFM 368 / 780 387 / 820 472 / 1000

dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46

mm/in 285 / 11.2

mm/in 1903 / 74.9

mm/in 680 / 26.8

kg/lb 85 / 187.4

mm/in 12.7 / 1/2

mm/in

70 / 154.3

1714 / 67.4

670 / 26.3

249 / 9.8

EXV

220 - 240 / 1 / 50

R-22

9.5 / 3/8

FLARE VALVE

19.1 / 3/4

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

MCCD-C

EXTERNAL STATIC PRESSURE (H/M/L)

LIQUIDGAS

MODEL

AIR FLOW(LOW STATIC)

AIR FLOW

CONTROL

LOW

DEPTH

LOW

UNIT DIMENSION

HEIGHT

INDOOR UNIT

REFRIGERANT TYPE

HIGH

MEDIUM

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL(LOW STATIC, H/M/L)

WEIGHT

PIPE CONNECTIONTYPE

SIZE15.9 / 5/8

EXTERNAL STATIC PRESSURE(LOW STATIC, H/M/L)

IND

OO

R U

NIT

MCCD 025C

22200

6500

25200

7400

270 / 580

360 / 770

340 / 720

270 / 580

49 / 43 / 30 (0.20 / 0.17 / 0.12)

40 / 39 / 35

261 / 10.3

1200 / 47.2

411 / 16.2

25 / 55.1

9.5 / 3/8

MCCD 020C

19100

5600

21500

6300

300 / 640

310 / 650

300 / 640

270 / 570

49 / 45 / 41 (0.20 / 0.18 / 0.17)

20 / 18 / 11 (0.08 / 0.07 / 0.04)20 / 19 / 15 (0.08 / 0.07 / 0.06)

38 / 37 / 35

261 / 10.3

1065 / 41.9

411 / 16.2

22 / 48.5

220 - 240 / 1 / 50

R-22

REFRIGERANT CONTROL (EXPANSION DEVICE) EXV

FLARE VALVE

MCCD 015C

12300

3600

13600

4000

190 / 400

250 / 540

240 / 500

180 / 380

36 / 33 / 28

21 / 46.3

12.7 / 1/2

261 / 10.3

905 / 35.6

411 / 16.2

6.4 / 1/4

MCCD 010C

9600

2800

10900

3200

120 / 260

140 / 300

130 / 275

110 / 225

49 / 44 / 36 (0.20 / 0.18 / 0.15) 49 / 42 / 28 (0.20 / 0.17 / 0.11)

10 / 8 / 5 (0.04 / 0.03 / 0.02) 10 / 8 / 5 (0.04 / 0.03 / 0.02)

33 / 30 / 25

17 / 37.5

9.5 / 3/8

261 / 10.3

765 / 30.1

411 / 16.2

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

HIGH

MEDIUM

340 / 730

310 / 660

330 / 700

320 / 675

240 / 510

230 / 490

140 / 300

130 / 285

l/s / CFM

l/s / CFM

OPERATION WIRED CONTROL

AIR DISCHARGE DUCTED

l/s / CFM

Pa (in.wg.)

Pa (in.wg.)

dBA

SOUND PRESSURE LEVEL (H/M/L) 41 / 40 / 3642 / 41 / 4040 / 38 / 3336 / 35 / 33dBA

mm/in

mm/in

mm/in

kg/lb

mm/inmm/in

EXTERNAL STATIC PRESSURE (H/M/L)

LIQUIDGAS

LOW

CONTROL

UNIT DIMENSION

HEIGHT

INDOOR UNIT

REFRIGERANT TYPE / CONTROL

HIGH

MEDIUM

AIR DISCHARGE

OPERATION

MODEL

AIR FLOW(LOW STATIC)

SUPER HIGH

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL (H/M/L)

WEIGHT

PIPE CONNECTIONTYPE

SIZE

DEPTH

MCCD-C

IND

OO

R U

NIT

MCCD 060C

56000

16400

63100

18500

802 / 1700

765 / 1620

717 / 1520

693 / 1470

176/157/137/98(0.71/0.63/0.55/0.39)

55 / 53 / 50 / 47

378 / 14.9

1499 / 59.0

541 / 21.3

62 / 136.7

12.7 / 1/2

MCCD 050C

47800

14000

54600

16000

713 / 1510

628 / 1330

618 / 1310

599 / 1270

176/157/137/108(0.71/0.63/0.55/0.43)

53 / 52 / 50 / 47

378 / 14.9

1299 / 51.1

541 / 21.3

54 / 119.1

19.1 / 3/4

FLARE VALVE

R-22 / EXV

DUCTED

WIRED CONTROL

220 - 240 / 1 / 50

MCCD 040C

38200

11200

42700

12500

562 / 1190

500 / 1060

472 / 1000

458 / 970

206/176/127/93(0.83/0.71/0.51/0.37)

69/49/29/20(0.28/0.20/0.12/0.08)78/59/39/20(0.31/0.24/0.16/0.08)49/39/29/20(0.20/0.16/0.12/0.08)

51 / 49 / 45 / 41

378 / 14.9

1045 / 41.1

541 / 21.3

42 / 92.6

9.5 / 3/8

MCCD 030C

30700

9000

34100

10000

444 / 940

415 / 880

373 / 790

349 / 740

206/167/127/88(0.83/0.67/0.51/0.35)

49/39/29/20(0.20/0.16/0.12/0.08)

49 / 46 / 42 / 38

378 / 14.9

929 / 36.6

541 / 21.3

39 / 86.0

15.9 / 5/8

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

l/s / CFM

LOW

HIGH

MEDIUMAIR FLOW

SUPER HIGH 779 / 1650

722 / 1530

675 / 1430

609 / 1290

750 / 1590

651 / 1380

604 / 1280

571 / 1210

519 / 1100

500 / 1060

467 / 990

425 / 900

425 / 900

392 / 830

359 / 760

335 / 710

l/s / CFM

l/s / CFM

l/s / CFM

l/s / CFM

Pa (in.wg.)

EXTERNAL STATIC PRESSURE(LOW STATIC, H/M/L)

Pa (in.wg.)

dBA

SOUND PRESSURE LEVEL(LOW STATIC, H/M/L)

48 / 47 / 46 / 4546 / 44 / 43 / 4243 / 41 / 40 / 3841 / 40 / 39 / 36dBA

mm/in

mm/in

mm/in

kg/lb

mm/inmm/in

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).

MDBD

Btu/hW

Btu/hW

V/Ph/Hz

l/s / CFMl/s / CFMl/s / CFM

EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)dBA

mm/inmm/inmm/inkg/lb

LIQUID mm/inGAS mm/in

MDBD 080764002240085300

1700

1167 / 24721034 / 2201833 / 1766100 / 0.40

420 / 16.5

28.6 / 1 1/8

MODEL

AIR FLOW

DEPTH

LOW

CONTROL

UNIT DIMENSION HEIGHT

INDOOR UNIT

REFRIGERANT CONTROL (EXPANSION DEVICE)

HIGH MEDIUM

AIR DISCHARGEOPERATION

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL (H/M/L)

WEIGHT

1690 / 66.5879 / 34.6100 / 220

PIPE CONNECTIONTYPE

SIZE12.7 / 1/2 12.7 / 1/2

WNOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

IND

OO

R U

NIT

MDBD 1009550028000107500

148025000 31500

1389 / 2943--

150 / 0.60

520 / 20.51580 / 62.2

57 / 55 / 52 57

1020 / 40.2150 / 330

28.6 / 1 1/8

220 ~ 240 / 1 / 50 380 ~ 415 / 3 / 50

EXV

WIRED CONTROLDUCTED

FLARE VALVE

R-22

Page 18: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-410A Outdoor Specification

R-410A1

R-410A2

5MDS-B

5MDS 050BR 5MDS 060BR 5MDS 070BR

Btu/h 46,000 51,100 64,800

W 13,500 15,000 19,000

Btu/h 51,100 59,700 71,600

W 15,000 17,500 21,000

COOLING W 4,400 4,900 <4,700> 6,400

HEATING W 4,300 4,800 <4,400> 6,200

5MDS 050B 5MDS 060B 5MDS 070B

Btu/h 46,000 51,100 64,800

W 13,500 15,000 19,000

W 4,400 4,900 <4,700> 6,400

V/Ph/Hz 380-415 / 3 / 50 220-240/1/50 <380-415 / 3 / 50> 380-415 / 3 / 50

R-410A R-410A R-410A

l/s / cfm 611 + 611 / 1295 + 1295 833 + 833 / 1766 + 1766 889 + 889 / 1883 + 1883

dB(A) 59 60 62

HEIGHT mm/in 1044 / 41.4 1247 / 49.1 1349 / 53.1

WIDTH mm/in 1058 / 41.7 1058 / 41.7 1058 / 41.7

DEPTH mm/in 430 / 16.9 430 / 16.9 430 / 16.9

kg/lb 117 / 258 125 / 276 135 / 297

kg/lb 120 / 265 130 / 287 140 / 309

FLARE / BRAZE FLARE / BRAZE FLARE / BRAZE

LIQUID mm/in 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8

GAS mm/in 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8

HEATPUMPUNIT WEIGHT

SIZE

NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>

POWER SOURCE - 1Ø <3Ø>

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

PIPE CONNECTION

TYPE (LIQUID/GAS)

COOLING ONLY

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR 1SO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

5MDS-B

5MDS 080BR 5MDS 100BR 5MDS 120BR 5MDS 140BR 5MDS 160BR

Btu/h 85,300 95,536 112,596 129,656 143,304

W 25,000 28,000 33,000 38,000 42,000

Btu/h 95,536 109,184 126,244 143,304 160,364

W 28,000 32,000 37,000 42,000 47,000

COOLING W 7,200 8,000 9,700 11,300 12,900

HEATING W 7,000 7,900 9,400 10,900 11,900

5MDS 080B 5MDS 100B 5MDS 120B 5MDS 140B 5MDS 160B

Btu/h 85,300 95,536 112,596 129,656 143,304

W 25,000 28,000 33,000 38,000 42,000

W 7,200 8,000 9,700 11,300 12,900

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A R-410A R-410A

HI-FAN l/s / cfm 3056 / 6474 3056 / 6474 3056 / 6474 3333 / 7063 3333 / 7063

LOW-FAN l/s / cfm 1611 / 3414 1611 / 3414 1611 / 3414 1778 / 3767 1778 / 3767

dB(A) 56 57 60 60 60

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8 1290 / 50.8

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 275 / 606 285 / 628 290 / 639 335 / 739 345 / 761

kg/lb 290 / 639 300 / 661 305 / 672 350 / 771 360 / 793

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 9.5 / 3/8 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2

GAS mm/in 22.2 / 7/8 22.2 / 7/8 22.2 / 7/8 28.6 / 1 1/8 28.6 / 1 1/8

kg/lb 7.9 / 17.4 9.2 / 20.3 10.6 / 23.4 12.2 / 26.9 13.4 / 29.5

UNIT WEIGHTCOOLING ONLY

HEATPUMP

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

PIPE CONNECTION

OUTDOOR UNIT

TYPE (LIQUID/GAS)

SIZE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO 13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

5MDS-B5MDS 280BR 5MDS 300BR 5MDS 320BR 5MDS 340BR 5MDS 360BR

5MDS 120BRM + 5MDS 160BRS 5MDS 120BRM + 5MDS 180BRS 5MDS 180BRM + 5MDS 140BRS 5MDS 180BRM + 5MDS 160BRS 5MDS 180BRM + 5MDS 180BRS

Btu/h 255,900 272,960 290,020 303,668 320,728

W 75,000 80,000 85,000 89,000 94,000

Btu/h 286,608 307,080 324,140 341,200 361,672

W 84,000 90,000 95,000 100,000 106,000

COOLING W 22,600 24,200 25,800 27,400 29,000

HEATING W 21,300 23,200 24,700 25,700 27,600

5MDS 280B 5MDS 300B 5MDS 320B 5MDS 340B 5MDS 360B

5MDS 120BM + 5MDS 160BS 5MDS 120BM + 5MDS 180BS 5MDS 180BM + 5MDS 140BS 5MDS 180BM + 5MDS 160BS 5MDS 180BM + 5MDS 180BS

Btu/h 255,900 272,960 290,020 303,668 320,728

W 75,000 80,000 85,000 89,000 94,000

W 22,600 24,200 25,800 27,400 29,000

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A R-410A R-410A

HI-FAN l/s / cfm 3056 + 3333 / 6474 + 7063 3056 + 3472 / 6474 + 7357 3472 + 3333 / 7357 + 7063 3472 + 3333 / 7357 + 7063 3472 + 3472 / 7357 + 7357

LOW-FAN l/s / cfm 1611 + 1778 / 3414 + 3767 1611 + 2083 / 3414 + 4414 2083 + 1778 / 4414 + 3767 2083 + 1778 / 4414 + 3767 2083 + 2083 / 4414 + 4414

dB(A) 62 62 63 63 63

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 2290 / 90.2 2290 / 90.2 2590 / 102.0 2590 / 102.0 2590 / 102.0

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 635 / 1400 645 / 1422 690 / 1521 700 / 1543 710 / 1565

kg/lb 665 / 1466 675 / 1488 720 / 1587 730 / 1609 740 / 1631

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 15.9 / 5/8 15.9 / 5/8 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4

GAS mm/in 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8 34.9 / 1 3/8

kg/lb 24.0 / 52.9 30.0 / 66.1 32.0 / 70.5 34.0 / 75.0 34.0 / 75.0

UNITWEIGHT

COOLING ONLY

HEATPUMP

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

UNIT DIMENSION

PIPECONNECTION

NOMINAL TOTALINPUT POWER

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

NOMINAL COOLING CAPACITY

MASTER UNIT+SLAVE UNIT

OUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

MODEL

5MDS-B

5MDS 180BR 5MDS 200BR 5MDS 220BR 5MDS 240BR 5MDS 260BR

- - - - 5MDS 120BRM + 5MDS 140BRS

Btu/h 160,364 180,836 197,896 218,368 242,252

W 47,000 53,000 58,000 64,000 71,000

Btu/h 180,836 201,308 221,780 242,252 269,548

W 53,000 59,000 65,000 71,000 79,000

COOLING W 14,500 16,200 17,700 19,800 21,000

HEATING W 13,800 14,700 16,900 18,500 20,300

5MDS 180B 5MDS 200B 5MDS 220B 5MDS 240B 5MDS 260B

- - - - 5MDS 120BM + 5MDS 140BS

Btu/h 160,364 180,836 197,896 218,368 242,252

W 47,000 53,000 58,000 64,000 71,000

W 14,500 16,200 17,700 19,800 21,000

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A R-410A R-410A

HI-FAN l/s / cfm 3472 / 7357 3056 +3056 / 6474 +6474 3056 + 3056 / 6474 + 6474 3056 + 3056 / 6474 + 6474 3056 + 3333 / 6474 + 7063

LOW-FAN l/s / cfm 2083 / 4414 1611 + 1611 / 3414 + 3414 1611 + 1611 / 3414 + 3414 1611 + 1611 / 3414 + 3414 1611 + 3414 / 1778 + 3767

dB(A) 61 61 62 62 62

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 1290 / 50.8 1990 / 78.3 1990 / 78.3 1990 / 78.3 2290 / 90.2

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 355 / 783 560 / 1235 560 / 1235 570 / 1257 625 / 1378

kg/lb 370 / 816 590 / 1301 590 / 1301 600 / 1323 655 / 1444

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8

GAS mm/in 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 28.6 / 1 1/8 34.9 / 1 3/8

kg/lb 14.8 / 32.6 18.0 / 39.7 19.6 / 43.2 21.5 / 47.4 22.8 / 50.3

MODELMASTER UNIT+SLAVE UNIT

MODELMASTER UNIT+SLAVE UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

HEATPUMP

NOMINAL TOTALINPUT POWER

POWER SOURCE

REFRIGERANT TYPE

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

OUTDOOR UNIT

OU

TD

OO

R U

NIT

PIPECONNECTION

TYPE (LIQUID/GAS)

SIZE

REFRIGERANT CHARGE

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNITWEIGHT

COOLING ONLY

Page 19: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-410A Indoor Specifications

IND

OO

R U

NIT

M5WMD-G

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

INDOOR MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

SIZE

POWER SOURCE

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

UNIT DIMENSION

AIR FLOW

PIPE CONNECTION

TYPE

M5WMD 009G2 M5WMD 010G2 M5WMD 015G2

Btu/h 8500 9600 12300

W 2500 2800 3600

Btu/h 9600 10900 13600

W 2800 3200 4000

V/Ph/Hz

l/s / cfm 130 / 275 142 / 300 163 / 345

l/s / cfm 106 / 225 118 / 250 135 / 285

R-410A

EXV

l/s / cfm 83 / 175 94 / 200 104 / 220

dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29

mm/in

mm/in 799 / 31.5

mm/in

kg/lb 10 / 22.0

mm/in

mm/in 12.7 / 1/2

220-240/1/50

FLARE VALVE

9.5 / 3/8

12 / 26.5

899 / 35.4

6.4 / 1/4

260 / 10.2

198 / 7.8

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

IND

OO

R U

NIT

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

INDOOR MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

AIR FLOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

M5WMD 025G2

Btu/h 22200

W 6500

Btu/h 25200

W 7400

V/Ph/Hz

l/s / cfm 397 / 630

l/s / cfm 231 / 490

l/s / cfm 208 / 440

dBA 49 / 44 / 42

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

16 / 35.3

FLARE VALVE

6.4 / 1/4

15.9 / 5/8

220-240/1/50

304 / 12.0

1062 / 41.8

222 / 8.7

M5WMD 020G2

19100

5600

21500

6300

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE) EXV

R-410A

231 / 490

193 / 410

160 / 340

43 / 40 / 35

12.7 / 1/2

M5WMD-G

R-410A3

R-410A4

5MDS-B5MDS 380BR 5MDS 400BR 5MDS 420BR 5MDS 440BR

5MDS 240BRM + 5MDS 140BRS 5MDS 240BRM + 5MDS 160BRS 5MDS 240BRM + 5MDS 180BRS 5MDS 240BRM + 5MDS 200BRS

Btu/h 348,024 361,672 378,732 399,204

W 102,000 106,000 111,000 117,000

Btu/h 385,556 402,616 423,088 443,560

W 113,000 118,000 124,000 130,000

COOLING W 31,100 32,700 34,300 36,000

HEATING W 29,400 30,400 32,300 33,200

5MDS 380B 5MDS 400B 5MDS 420B 5MDS 440B

5MDS 240BM + 5MDS 140BS 5MDS 240BM + 5MDS 160BS 5MDS 240BM + 5MDS 180BS 5MDS 240BM + 5MDS 200BS

Btu/h 348,024 361,672 378,732 399,204

W 102,000 106,000 111,000 117,000

W 31,100 32,700 34,300 36,000

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A R-410A

HI-FAN l/s / cfm 3056 x 2 + 3333 / 6474 x 2 + 7063 3056 x 2 + 3333 / 6474 x 2 + 7063 3056 x 2 + 3472 / 6474 x 2 + 7357 3056 x 4 / 6474 x 4

LOW-FAN l/s / cfm 1611 x 2 + 1778 / 3414 x 2 + 3767 1611 x 2 + 1778 / 3414 x 2 + 3767 1611 x 2 + 2222 / 3414 x 2 + 4414 1611 x 4 / 3414 x 4

dB(A) 64 65 65 65

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 3290 / 129.5 3290 / 129.5 3290 / 129.5 3990 / 157.1

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 905 / 1995 915 / 2017 925 / 2039 1130 / 2491

kg/lb 950 / 2094 960 / 2116 970 / 2138 1190 / 2624

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4

GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8

kg/lb 38.0 / 83.4 40.0 / 88.2 42.0 / 92.6 44.0 / 97.0

NOMINAL COOLING CAPACITY

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

UNIT DIMENSION

PIPE CONNECTION

UNIT WEIGHTCOOLING ONLY

HEATPUMP

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

MASTER UNIT+SLAVE UNIT

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

5MDS-B5MDS 460BR 5MDS 480BR 5MDS 500BR

5MDS 240BRM + 5MDS 220BRS 5MDS 240BRM + 5MDS 240BRS 5MDS 250BRM + 5MDS 250BRS

Btu/h 416,264 436,736 457,208

W 122,000 128,000 134,000

Btu/h 464,032 484,504 504,976

W 136,000 142,000 148,000

COOLING W 37,500 39,600 41,800

HEATING W 35,400 37,000 39,000

5MDS 460B 5MDS 480B 5MDS 500B

5MDS 240BM + 5MDS 220BS 5MDS 240BM + 5MDS 240BS 5MDS 250BM + 5MDS 250BS

Btu/h 416,264 436,736 457,208

W 122,000 128,000 134,000

W 37,500 39,600 41,800

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A

HI-FAN l/s / cfm 3056 x 4 / 6474 x 4 3056 x 4 / 6474 x 4 3056 x 4 / 6474 x 4

LOW-FAN l/s / cfm 1611 x 4 / 3414 x 4 1611 x 4 / 3414 x 4 1611 x 4 / 3414 x 4

dB(A) 65 65 65

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 3990 / 157.1 3990 / 157.1 3990 / 157.1

DEPTH mm/in 840 / 33.1 840 / 33.1 840 / 33.1

kg/lb 1130 / 2491 1140 / 2513 1160 / 2557

kg/lb 1190 / 2624 1200 / 2646 1220 / 2690

Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 19.1 / 3/4 19.1 / 3/4 19.1 / 3/4 GAS mm/in 41.3 / 1 5/8 41.3 / 1 5/8 41.3 / 1 5/8

kg/lb 46.0 / 101.4 48.0 / 105.8 50.0 / 110.2

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

UNIT WEIGHTCOOLING ONLY

HEATPUMP

NOMINAL COOLING CAPACITY

REFRIGERANT CHARGE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

POWER SOURCE

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

Page 20: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

R-410A5

R-410A6

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4a) M5CKD020-025A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA4b) M5CKD030-040A: SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

IND

OO

R U

NIT

M5CKD-A

LIQUID

GAS

HIGH

MEDIUM

HEIGHT

SOUND PRESSURE LEVEL (H/M/L)

DEPTH

PIPE CONNECTION

TYPE

SIZE

INDOOR MODEL

LOW

POWER SOURCE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

WIDTH

AIR FLOW

WEIGHT (UNIT + PANEL)

UNIT DIMENSION ( ) - WITH PANEL

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

M5CKD 020A M5CKD 025A M5CKD 030A M5CKD 040A M5CKD 050A

19100 22200 30700 38200 47800

5600 6500 9000 11200 14000

21500 25200 34100 42700 54600

6300 7400 10000 12500 16000

349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040

297 / 630 311 / 660 349 / 740 406 / 860 448 / 950

283 / 600 283 / 600 321 / 680 359 / 760 411 / 870

42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50

31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8

6.4 / 1/4 6.4 / 1/4 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8

12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8

820 (930) / 32.2 (36.6)

220-240/1/50

R-410A

EXV

335 (378) / 13.2 (14.9)

820 (930) / 32.2 (36.6)

FLARE VALVE

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

M5CKD-C

LIQUID

GAS

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

UNIT WEIGHT (UNIT + PANEL)

PIPE CONNECTION

TYPE

SIZE

DEPTH

LOW

UNIT DIMENSION ( ) - WITH PANEL

IND

OO

R U

NIT

POWER SOURCE

AIR FLOW

HIGH

SOUND PRESSURE LEVEL (H/M/L)

HEIGHT

WIDTH

INDOOR MODEL

MEDIUM

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

M5CKD 010C M5CKD 015C M5CKD 020C

9600 12300 19100

2800 3600 5600

10900 13600 21500

3200 4000 6300

194 / 410 194 / 410 212 / 450

170 / 360 170 / 360 194 / 410

156 / 330 156 / 330 160 / 340

41 / 38 / 35 41 / 38 / 34 44 / 41 / 37

22 + 2 / 48.5 + 4.4 23 + 2 / 50.7 + 4.4 23 + 2 / 50.7 + 4.4

FLARE VALVE

6.4 / 1/4

9.5 / 3/8 12.7 / 1/2 12.7 / 1/2

220 - 240 / 1 / 50

250 (295) / 9.8 (11.6)

570 (640) / 22.4 (25.2)

570 (640) / 22.4 (25.2)

FLARE VALVE

Btu/h

W

Btu/h

W

V/Ph/Hz

REFRIGERANT CONTROL (EXPANSION DEVICE) EXV

REFRIGERANT TYPE R-410A

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

M5CMD-E

LIQUID

GAS

LOW

NOMINAL COOLING CAPACITY

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

HIGH

MEDIUM

NOMINAL HEATING CAPACITY

POWER SOURCE

PIPE CONNECTION

TYPE

SIZE

UNIT WEIGHT

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

IND

OO

R U

NIT

UNIT DIMENSION

M5CMD 015E M5CMD 020E M5CMD 025E M5CMD 028E

12300 19100 22200 27300

3600 5600 6500 8000

13600 21500 25200 30700

4000 6300 7400 9000

240 / 508 245 / 520 274 / 580 302 / 640

182 / 386 217 / 460 250 / 530 264 / 560

165 / 350 192 / 406 231 / 490 217 / 460

48 / 43 / 41 48 / 46 / 43 50 / 47 / 46 51 / 48 / 47

26 / 57.3 27 / 59.5 27 / 59.5 28 / 61.7

9.5 / 3/8

218 / 8.6

1080 / 42.5

630 / 24.8

220 - 240 / 1 / 50

REFRIGERANT TYPE R-410A

REFRIGERANT CONTROL (EXPANSION DEVICE) EXV

FLARE VALVE

12.7 / 1/2

6.4 / 1/4

15.9 / 5/8

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

IND

OO

R U

NIT

M5CMD-D/C

LIQUID

GAS

PIPE CONNECTION

TYPE

SIZE

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

AIR FLOW

HIGH

MEDIUM

LOW

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

INDOOR MODEL M5CMD 040D M5CMD 050D M5CMD 062C

Btu/h 38200 47800 56000

W 11200 14000 16400

Btu/h 42700 54600 63100

W 12500 16000 18500

V/Ph/Hz

l/s / CFM 477 / 1010 491 / 1040 732 / 1550

l/s / CFM 420 / 890 448 / 950 623 / 1320

l/s / CFM 368 / 780 387 / 820 472 / 1000

dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46

mm/in 285 / 11.2

mm/in 1903 / 74.9

mm/in 680 / 26.8

kg/lb 85 / 187.4

mm/in

mm/in 19.1 / 3/4

670 / 26.3

220 - 240 / 1 / 50

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

R-410A

EXV

70 / 154.3

249 / 9.8

FLARE VALVE

9.5 / 3/8

15.9 / 5/8

1714 / 67.4

Page 21: All Product Catalogue AP-MDS-12 › 2016 › 03 › ap-md… · All Product Catalogue AP-MDS-12 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

M5CCD-C

Btu/h 9600 12300 19100 22200 27300

W 2800 3600 5600 6500 8000

Btu/h 10900 13600 21500 25200 30700

W 3200 4000 6300 7400 9000

V/Ph/Hz

l/s / CFM 118 / 250 194 / 410 270 / 570 326 / 690 382 / 810

l/s / CFM 112 / 235 175 / 370 264 / 558 312 / 660 363 / 770

l/s / CFM 100 / 210 118 / 250 227 / 480 253 / 535 335 / 710

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.)29 / 20 / 10

(0.12 / 0.08 / 0.04) (0.12 / 0.08 / 0.04) (0.12 / 0.08 / 0.04) (0.4 / 0.3 / 0.3 / 0.2)29 / 20 / 10 29 / 20 / 10 29 / 20 / 10

(0.12 / 0.08 / 0.04)98 / 78 / 68 / 59

dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 44 / 41 / 38 / 34

mm/in 285 / 11.2

mm/in 765 / 30.1 905 / 35.6 1065 / 41.9 1200 / 47.2 1007 / 39.6

mm/in 600 / 23.6

kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 38 / 83.8

LIQUID mm/in 9.5 / 3/8GAS mm/in 9.5 / 3/8

220 - 240 / 1 / 50

PIPE CONNECTION

TYPE

SIZE15.9 / 5/8

WEIGHT

UNIT DIMENSION

LOW

SOUND PRESSURE LEVEL (SH/H/M/L)

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

HIGH

MEDIUM

POWER SOURCE

AIR FLOW

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

FLARE VALVE

411 / 16.2

6.4 / 1/412.7 / 1/2

261 / 10.3

R-410A

EXV

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

l/s / CFM - - - - 401 / 850SUPER HIGH

IND

OO

R U

NIT

M5CCD 010C M5CCD 015C M5CCD 020C M5CCD 025C M5CCD 028C

Btu/h 30700 34100 38200 47800 56000

W 9000 10000 11200 14000 16400

Btu/h 34100 38200 42700 54600 63100

W 10000 11200 12500 16000 18500

V/Ph/Hz

l/s / CFM 604 / 1280 675 / 1430 812 / 1720

l/s / CFM 547 / 1160 623 / 1320 732 / 1550

l/s / CFM 496 / 1050 580 / 1230 632 / 1340

l/s / CFM 434 / 920 533 / 1130 552 / 1170

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 118 / 96 / 78 / 61 (0.5 / 0.4 / 0.3 / 0.2) (0.5 / 0.4 / 0.3 / 0.2) (0.6 / 0.5 / 0.4 / 0.3) (0.6 / 0.5 / 0.4 / 0.3)

147 / 126 / 109 / 92 147 / 120 / 90 / 69

dBA 52 / 49 / 48 / 45

566 / 1200

486 / 1030

406 / 860

349 / 740

120 / 86 / 64 / 45(0.5 / 0.3 / 0.3 / 0.2)

52 / 49 / 48 / 45 54 / 53 / 52 / 51

628 / 1330

571 / 1210

491 / 1040

425 / 900

120 / 98 / 74 / 54

51 / 49 / 45 / 41 54 / 52 / 50 / 46

mm/in 378 / 14.9 305 / 12.0 378 / 14.9 378 / 14.9 378 / 14.9

mm/in 929 / 36.6 1302 / 51.3 1045 / 41.1 1299 / 51.1 1499 / 59.0

mm/in 514 / 21.3 638 / 25.1 541 / 21.3 541 / 21.3 541 / 21.3

kg/lb 39 / 86.0 41 / 90.4 42 / 92.6 54 / 119.1 62 / 136.7

LIQUID mm/inGAS mm/in 19.1 / 3/4

220 - 240 / 1 / 50

AIR FLOW

LOW

POWER SOURCE

HIGH

PIPE CONNECTION

TYPE

SIZE

DEPTH

WEIGHT

UNIT DIMENSION

9.5 / 3/815.9 / 5/8

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

MEDIUM

SUPER HIGH

HEIGHT

SOUND PRESSURE LEVEL (SH/H/M/L)

WIDTH

INDOOR MODEL

FLARE VALVE

IND

OO

R U

NIT

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON DUCTED PRODUCT) OR ISO13253 (DUCTED PRODUCT).3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

R-410A

EXVREFRIGERANT CONTROL (EXPANSION DEVICE)

REFRIGERANT TYPE

M5CCD-CM5CCD 030C M5CCD 038C M5CCD 040C M5CCD 050C M5CCD 060C

R-410A7