All Product Catalogue AP-MDS-09 A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration. Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. ©2009 McQuay International +1 (800) 432-1342 www.mcquay.com

All Product Catalogue AP-MDS-09 - Acson · PDF file · 2008-09-30All Product Catalogue AP-MDS-09 ... Australia Fiji New Zealand Papua New Guinea Middle East & Africa ... MCM-E MCM-D

Embed Size (px)

Citation preview

All Product Catalogue AP-MDS-09

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.

For the most up-to-date product information, please go to www.mcquay.com.

©2009 McQuay International +1 (800) 432-1342 www.mcquay.com

Manufacturing Plant

Minneapolis

Faribault

OwatonnaStauntan

Mexico City

Auburn

SuzhouWuhan

Shenzhen

Kuala Lumpur

Jakarta

Americas• USA • Puerto Rico • Mexico • Paraguay • Uruguay • Guadaloupe

Oceania• Australia • Fiji • New Zealand • Papua New Guinea

Middle East & Africa• Jordan • Lebanon • Oman • Qatar • Saudi Arabia • Bahrain • Morocco • Iraq • U.A.E. • Mauritius • South Africa • Kenya • Madagascar • Ghana • Nigeria • Tanzania

Europe• Albania • England • Greece • Hungary • Italy • Norway • Poland • Portugal • Russia • Spain • Belgium • Tunisia • Croatia • Cyprus • Lithuania • Malta • Turkey • Czech Republic Asia• Cambodia • China • Philippines • Hong Kong • India • Indonesia • Maldives • Myanmar • Nepal • Singapore • Thailand • Vietnam • Pakistan

Cramlington

Cecchina

Multi Digital ScrollSystem Features 4Application 12Outdoor Features 14Indoor Features 16Integrated Software 23Controller And Accessories 24Project References 25

SpecificationsR-22 Outdoor R-22 - 1R-22 Indoor R-22 - 3R-410A Outdoor R-410A - 1R-410A Indoor R-410A - 4

1

5MDS 080/100/120/140/160/180BR

5MDS 050/060/070A/AR

25.0 - 47.0 28.0 - 53.0

5MDS 380/400/420BR

5MDS 200/220/240/260/280/300/320/340/360BR 53.0 - 94.0

102.0 - 111.0

59.0 - 106.0

113.0 - 124.0

5MDS 440/460/480/500BR 117.0 - 134.0 130.0 - 148.0

Model RangeCooling

Capacity (kW)Heating

Capacity (kW)

Model RangeCooling

Capacity (kW)Heating

Capacity (kW)

8.5 - 18.0

MDS 080/100/120/150B/BR

MDS 180/200/220/240/260/280/300/320B/BR

24.5 – 40.0

9.0 - 20.0

13.5 – 19.0 15.0 – 21.0

26.0 – 43.0

47.5 – 85.0 50.0 – 92.0

MDS 030/040/050/060/070A/AR

Split Type IndoorModel Range Cooling

Capacity (kW)Heating

Capacity (kW)R-410AR-22

MWM-G

MCK-A

MCK-C

MCM-E

MCM-D

MCC-C

MDB

HORIZONTALDISCHARGE

VERTICALDISCHARGE

VERTICALDISCHARGE

HORIZONTAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

VERTICAL DISCHARGE

2.5 - 6.5

5.6 - 14.0

2.8 - 5.6

5.6 - 8.0

11.2 - 16.4

2.8 - 7.4

6.3 - 16.0

3.2 - 6.3

6.3 - 9.0

2.8 - 16.4 3.2 - 18.5

22.4 – 25.0 28.0 – 31.5

2 3

MDS R-410A Condensing Unit

MDS R-22 Condensing Unit

12.5 - 18.5

MORE ECONOMICAL OPERATIONWith higher IPLV, MDS is able to operate with lower power consumption.

4

NO CONVERSION LOSTComparing to the traditional inverter drive air-conditioner, MDS has eliminated the possibility of lost of energy during the conversion of power signal.

BETTER DEHUMIDIFYING PERFORMANCEThe continuously operating compressor in the MDS system provides better dehumidifying performance, and hence able to reduce the indoor RH to a more desired level. With lower RH in the interior, the growth of the bacteria and fungus are inhabited.

BETTER PART LOAD EFFICIENCYMost air-conditioning system operates in the 30%~70% region. Integrated with the digital scroll compressor technology, MDS is capable to modulate its supply capacity to meet most indoors requirement closely. This modulating capability enable the MDS system to offer higher IPLV (Integrated Part Load Value).

Utilising the digital scroll compressor technology, the McQuay Multi Digital ScrollSystem (MDS) is seen as the next generation products for high-efficiency air conditioning.

AC Converted FrequencyInverter

Compressor

Capacity Controller

TransformationConcumption = 0%

MotorConsumption

= 5-10%

DCAC DCTransformer

AC DCFrequency Conversion

T rad i t i ona l I n ve r t e r Sys tem

DigitalCompressorAC PWM valve

Capacity Controller

TransformationComsumption = 0%

MDS Sys tem

5th

7th

11th

13th

17th

19th

0 1 2 3 4 5

MDS System EMC Standard Inverter System

EMC comparison during development stage

Temp.

Time1 2 3 4

Tr

Ts

The temperature fluctuation range of traditional air conditioning system

The temperature fluctuation range of MDS system

Tr = Room TemperatureTs = Set Temperature

5

MDS 100B System

100%

5%

FixedCompressorOperating

DigitalOperating

DigitalOperating

Loading Unloading

MDS100BR IPLV Testing

2

2.5

3

3.5

4

4.5

0 20 40 60 80 100

IPLV(C) = 3.56

IPLV(H) = 3.71

Capacity (%)

Cooling

Heating

COP (W/W)

IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoorand 27°C DB outdoorHeating cycle:20°C DB / 15°C WB indoorand 7°C DB / 6°C WB outdoor

IMPROVED ELECTROMAGNETIC COMPATIBILITYUnlike variable speed compressors air conditioners, MDS runs at a constant speed throughout the operation, thus there is lower electromagnetic interference. This unique feature reduces the need for expensive electromagnetic suppression electronics required to ensure electromagnetic compatibility.

TIGHTER TEMPERATURE CONTROLThe ambient of the outdoor and indoor change frequently and this will affect the indoor cooling and heating load. With MDS system, using an improved control algorithm, the temperature is kept closer to the set temperature.

6 7

Comparing to conventional chilled water system, MDS required far less equipment. Boilers, cooling tower are things in the past with MDS. Thus, MDS is a better solution for new projects or even retrofit purposes.

Conventional ChilledWater System

MDS System

PERFORMANCE CHOICESOLUTIONS

Temperature °C

43°CDB

0°CDB

16°CWB

-15°CWDB

50

40

30

20

10

0

-10

-20

Cooling Cycle Heating Cycle

WIDER OPERATING RANGEMDS system undergo rigorous test to ensure that the system can operate within -15ºC to 43ºC.

INTELLIGENT CAPACITY MODULATIONThe MDS system operates in a stepless capacity modulation ranging from 10~100%. The modulation will closely match the demand capacity whereby contributing higher IPLV.

t1 t2Time

InitialTemperature

SettingTemperature

Traditional Air ConditioningMDS System

RAPID COOLING AND HEATING CAPABILITYThe improved heat-exchanger combining with the better efficiency compressor promotes rapid exchange between refrigerant and air, ensuring set temperature to be achieved faster compared to traditional air-conditioning system.

Height15m

PipingLength150m

Height50m

LONG PIPING DESIGN FOR FLEXIBILITYPiping length between outdoor and indoor unit can be extended up to 150 meters. The height between outdoor unit and indoor unit can be extended up to 50 meters. The height difference between indoor units can be as high as 15 meters. This greatly reduces constraint and offers more flexibility in system design.

The refnet joint is provided by the factory in accordance with different indoor units, which will reduce the work force at site.

Only a common 2-core, screen cable wire is required to enable communication between outdoor and indoors.

EASIER INSTALLATIONIn-house designed piping joints and wiring connection make it possible to install MDS system faster and easier.

BETTER PLACE UTILISATIONMDS uses the single outdoor multiple indoors combination. This concept has greatly reduced outdoor units and enhances flexibility during installation.

ALARM AND DIAGNOSIS SYSTEMThe MDS system is built in with an alarm system, alerting owners or users for abnormal operation.A user-friendly diagnosis system helps to identify the problems, ensuring continuous operation of the MDS system.

AUTOAUTO

FLOOR BY FLOOR INSTALLATION*The optional outdoor fan with external static pressure of 50Pa is suitable for short-discharge ductwork application. With this feature, an outdoor unit can be placed on each floor, thus allowing installation to be performed floor by floor.* Please contact your local sales office for more information.

VARIETY OF INDOORSThe MDS indoors come with a variety of design and capacity which can be selected to suit most air conditioning needs.

8 9

ADAPTS EASIER TO ANY FLOOR PLANThe wide indoor models can meet the needs of building size and interior design easier. Incorporate with the flexible piping design, the MDS system is suitable for most type of floor layout and various applications.

10 11

AUTO-RANDOM RESTARTAfter power failure, the MDS system will automatically restart operation base on the last state memory. Setting of the unit will not be lost, thus eliminating the needs for re-programming.

CENTRAL CONTROL SYSTEMThe MDS System Management Software is designed with user-friendly interface, enable simple monitoring and control of the system via a computer.

MDS-B series is capable to connect up to 48 units of indoors. Total indoor units capacity can range from 50% to 120% of the outdoor capacity.

LARGE CAPACITY

With all these advantages, it is very clear that MDS is a better solution for centralised air-condition system. What would be the consideration factor to select MDS? Here are some of the main consideration factors and examples.

HospitalConsideration:• Places that require low or no EMC interference • Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

OfficesConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Location for outdoor is limited• Centralized Control

Department Store / RestaurantConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

12 13

House / Apartment / CondominiumConsideration:• Location for outdoor is limited.• Various type of indoor unit with separate temperature requirement.• Heat load of the same air-conditioned area varies

Exhibition / Concert HallConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control

Factor 1Location for outdooris limited. MDS can be used due to the ability to couple multiple indoors with only 1 outdoor. Better space utilization.

Factor 2Various type of indoor unit with separate temperature requirementMDS system can be couple with various type of indoors. Each indoor can be design to supply to a specific area only and the temperature setting is base on individual indoor setting.

Factor 3Heat load of the same air-conditioned area variesMDS is able to match the indoor load requirement with its part loading capability.

Factor 5Places that require low or no EMC interferenceThe MDS modulation is control by mechanical parts. No change in power supply (frequency or current), thus lower electromagnetic interference.

Factor 4Centralized ControlMDS outdoors and indoors can be linked together and control using the MDS Control & Monitoring Software. The software can also perform scheduling of the indoor units base on the operating duration.

RELIABLE TECHNOLOGYMDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly.

• MDS system has better oil return performance even at low capacities, which will make sure that all of the removable parts of the compressor can be lubricated and cooled down.

• It reduces the start/stop times, which will reduce the attack to the electricity supply net.

• The PWM (Pulse Width Modulation) valve has the longevity of 40 million times.

• The design is simple and there is no requirment for bypass valve.

SMALL FOOTPRINTThe outdoor unit of MDS system is designed as package, the structure occupies less space and is easier to move.

The brain of the MDS system is the compressor which is incorporated in the outdoor condensing unit.With this technology, the outdoor is constructed in a uniform and solid design and focusing on smaller footprint to provide better space utilisation.

Unique Return Oil Technology

UNIFORM DESIGNThe outdoor units can be located on the rooftop. The uniform outlook and dimension allows side by side installation.

QUIET OPERATIONThe condensing unit utilises an advanced spiral fan blades. The smooth material and fan blade design help to reduce the turbulent flow and thus reduce the air flow noise.

14 15

WMWall MountedG SeriesMWMD 009/010/015/020/025 GM5WMD 009/010/015/020/025 GCooling 8,500 Btu/h – 22,200 Btu/h 2.5 kW – 6.5 kWHeating 9,600 Btu/h – 25,200 Btu/h 2.8 kW – 7.4 kW

McQuay is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoGuard combines powerful sterilizing and deodorizing effect of NanoSilver and Nano-Photocatalyst.

Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into anti-bacterial applications ever since. Modern nanotechnology provides through full-infusion onto the filters and larger coated surface area.

16 17

New Aesthetically OutlookA smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design. The centrally located LED light makes it easier for user to check the operating conditions.

3-Fold Heat Exchanger

The compact design of this 3-foldstructure provides a large surfacearea for better & efficientheat exchange.

Double LouverThis new louver design together with its automatic air swing function fully optimizes the room comfort by distributing the air evenly to every corner of the room.

NanoPhotocatalyst -deVOCs & deodorization(150 times stronger than highperformance activated carbon)

Pre Filter

NanoSilver-bacteria &germs elimination

CKCeiling CassetteA Series & C SeriesMCKD 010/015/020 CMCKD 020/025/030/040/050 AM5CKD 010/015/020 CM5CKD 020/025/030/040/050 ACooling 9,600 Btu/h – 47,800 Btu/h 2.8 kW – 14.0 kWHeating 10,900 Btu/h – 54,600 Btu/h 3.2 kW – 16.0 kW

STYLISH AND SLIM PANELThe slim panel can be blended easily into most interior decoration and design.

700mm

CEILING AND FLOOR INSTALLATION OPTIONThe MCMD is designed with the option to install either below the ceiling or mounted at low wall position to suit most interior design requirement.

4 WAY AIR DISCHARGE AND AIR SWINGIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.

CCCeiling ConvertibleE SeriesMCMD 020/025/028 EM5CMD 015/020/025/028 ECooling 19,100 Btu/h - 27,300 Btu/h 5.6 kW - 8.0 kWHeating 21,500 Btu/h - 30,700 Btu/h 6.3 kW - 9.0 kW

700mm

BUILT-IN HIGH HEAD DRAIN PUMPThe unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.

FLEXIBLE INSTALLATION The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.

18 19

BETTER SERVICEABILITYThe washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access. • Fan Motor• Blower• Wiring Connection• Control Box• Piping Connection

Wall bracket supplied as optional item

Primary Drain PanPolysterene (Ps) With Height Impact Polystyrene (Hips) Cover

Secondary Drain Pan With Insulation

Discharge Adaptor

Square GrilleAssembly c/w Adaptor

Secondary Drain Pan with Insulation

Primary Drain Pan

Square Return Grille Assembly

c/w Adaptor & Filter

FlexibleRound Duct(field supply)

Ceiling Concealed UnitACC Return AssemblyBracket c/w Adaptor

FlexibleRound Duct

(field supply)

Available for MCCD 010-025 C/CR only.

CMCeiling ConvertibleD SeriesMCMD 040/050 DMCMD 062 CM5CMD 040/050 DM5CMD 062 CCooling 38,200 Btu/h – 56,000 Btu/h 11.2 kW – 16.4 kWHeating 42,700 Btu/h – 63,100 Btu/h 12.5 kW – 18.5 kW

Ceiling ConcealedC SeriesMCCD 010/015/020/025/030/040/050/060 CM5CCD 010/015/020/025/028/030/038/040/050/060 CCooling 9,600 Btu/h – 56,000 Btu/h 2.8 kW – 16.4 kWHeating 10,900 Btu/h – 63,100 Btu/h 3.2 kW – 18.5 kW

CC

TWO WAY AIR DISCHARGE

Equipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.

AUTOMATIC AIR SWING

The swing mode enables the air flow to be evenly distributed into the room from the front discharge area.

CEILING AND FLOOR INSTALLING OPTION

The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit most interior design requirements.

DOUBLE PROTECTION DRAINAGE SYSTEM

The primary drain pan is designed with higher thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.

FLEXIBILITY IN SYSTEM DESIGN

The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system.

DUCT ACCESSORIES (OPTIONAL)

A set duct accessories specifically designed to fit and to suit the MCCD-C model is being created. Thus offers a one stop solution to installing the unit.

20 21

ICE CREAM

ICE CREAM

COMPLETE MODELTo ease installation, this model has the Electronic Expansion Valve (EXV) built into the unit. User do not need to worry about the noise from the EXV as it is properly insulated.

DBDucted BlowerMDBD 080 / 100Cooling 76,400 Btu/h – 95,500 Btu/h 22.4 kW – 28.0 kWHeating 85,300 Btu/h – 107,500 Btu/h 25.0 kW – 31.5 kW

MDS SYSTEM MANAGEMENT SOFTWAREFor central monitoring and control purposes, the MDS offers a real time system. This software is the system to human interface, allowing users or owners to monitor and to control the MDS system. With this software, user or owners is able to ;• Monitor & control any MDS indoor & outdoor unit • Alarming alert• Zoning & grouping capabilities • Scheduling option

BETTER AIR DISTRIBUTION FOR COMFORTABLE LIVINGThe conditioned air can be effectively distributed to the room through ducting.

EXTENDED INDOOR MODELThe ducted blower is designed to cater higher indoor capacity required. Combining ceiling concealed and ducted blower, the MDS system is able to fulfill ducted application with capacity range from 2.8kW to 28.0kW

As a system provider, McQuay MDS system is equipped together with a collection of customized software to provide system design & selection and individual units control & monitoring.

22 23

DESIGN SOFTWAREThis software is incorporated with data on indoor models. This allow the designers to choose the appropriate indoors model to suit they needs. Besides that, this software will determine the required quantity of refnet joints, pipes and other accessories base on the design. With this software, most designs can be completed with just a few simple clicks.

CENTRAL CONTROLLEROptional Item. To provide group or individual control to indoors (Up to 32 indoors). Basic control such as ON/OFF, mode setting, temperature setting and others.

AC 5300Optional Item. To provide wireless control for wired controller. Basic control such as ON/OFF, mode setting, temperature setting and others.

Standard Controller

Optional Controllerand Accessories

REFNET & DISTRIBUTORS JOINTPiping joint design for the MDS system. A total of 6 types of refnet joint is available for different piping combination.

PC CONTROLMDS Central Monitoring Software (known as Smart Commander) act as the system to human interface. A communication gateway is inclusive for the wiring connection.

WIRED CONTROLLERStandard wired controller for MCCD-C. Basic control such as ON/OFF, mode setting, tempera-ture setting and others.

WIRELESS G17Standard wireless handset for wall mounted, ceiling cassette and ceiling convertible. Basic control such as ON/OFF, mode setting, temperature setting and others.

Commercial SectorCountry : ThailandIndoor Type : Ceiling Concealed

Commercial SectorCountry : ChinaIndoor Type : Ceiling Concealed Ceiling Convertible

Residential SectorCountry : QatarIndoor Type : Wall Mounted

Residential SectorCountry : IndonesiaIndoor Type : Ceiling Concealed

Commercial SectorCountry : SingaporeIndoor Type : Ceiling Concealed Ceiling Convertible Ceiling Cassette

Residential SectorCountry : SyriaIndoor Type : Ceiling Concealed

MDS systems has proven to be reliable and a system of choice.Many projects, whether government or privately own premises had chosen MDS as their comfort provider:

24 25

R-221

R-222

R-22 Outdoor Specifications

COOLING

HEATING

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

NOMINAL COOLING CAPACITY

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>

NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>

UNIT DIMENSION

POWER SOURCE - 1Ø <3Ø>

REFRIGERANT TYPE

SOUND PRESSURE LEVEL

AIR FLOW

MODEL OUTDOOR UNIT

OU

TD

OO

R U

NIT

MDS 070AR

61,400

18,000

68,200

20,000

6,200

6,000

MDS 070A

61,400

18,000

6,200

380-415/3/50

R-22

2225/4694

62

1445/56.9

1058/41.6

430/16.9

140/309

Flare

9.52 / 3/8

19.05 / 3/4

MDS 060AR

49,474

14,500

56,298

16,500

5,000 <5,000>

4,200 <4,200>

MDS 060A

49,474

14,500

5,000 <5,000>

220-240/1/50 <380-415/3/50>

R-22

1055+1055/2230+2230

60

1247/49.1

1058/41.7

430/16.9

130/287

Flare

9.52 / 3/8

19.05 / 3/4

MDS 050AR

42,650

12,500

46,062

13,500

4,400 <4,300>

4,200 <3,900>

MDS 050A

42,650

12,500

4,400 <4,300>

220-240/1/50 <380-415/3/50>

R-22

695+695/1470+1470

59

1044/41.1

1058/41.7

430/16.9

120/265

Flare

9.52 / 3/8

19.05 / 3/4

MDS 040AR

34,120

10,000

39,238

11,500

3,500

3,400

MDS 040A

34,120

10,000

3,500

220-240/1/50

R-22

695+695/1470+1470

59

1044/41.1

1058/41.7

430/16.9

115/254

Flare

9.52 / 3/8

19.05 / 3/4

MDS 030AR

29,002

8,500

30,708

9,000

3,000

2,500

MDS 030A

29,002

8,500

3,000

220-240/1/50

R-22

1055/2230

59

900/35.4

840/33.0

408/16.0

85/188

Flare

9.52 / 3/8

15.88 / 5/8

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

MDS-AR

HI-FAN

LOW-FAN

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT WEIGHT

PIPE CONNECTION

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

SIZE

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

TYPE (LIQUID/GAS)

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

MDS 120BR MDS 150BR

110,890 136,480

32,500 40,000

116,008 146,716

34,000 43,000

9,800 12,900

9,000 11,100

MDS 120B MDS 150B

110,890 136,480

32,500 40,000

9,800 12,900

380-415/3/50

R-22 R-22

3472/7357 3750/7945

2083/4414 2222/4708

66 67

1840/72.4 1840/72.4

990/39.0 1290/50.8

840/33.0 840/33.0

290/639 355/783

Flare/Brazed Flare/Brazed

15.88/0.625 15.88/0.625

28.6/1.125 34.9/1.375

MDS 100BR

95,536

28,000

102,360

30,000

8,500

8,300

MDS 100B

95,536

28,000

8,500

R-22

3194/6768

1528/3237

64

1840/72.4

990/39.0

840/33.0

385/628

Flare/Brazed

12.7/0.5

28.6/1.125

MDS 080BR

83,594

24,500

88,712

26,000

7,500

7,200

MDS 080B

83,594

24,500

7,500

R-22

3194/6768

1528/3237

62

1840/72.4

990/39.0

840/33.0

275/606

Flare/Brazed

12.7/0.5

28.6/1.125

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

MDS-BR

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

HI-FAN

LOW-FAN

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

NOMINAL COOLING CAP ACITY

NOMINAL TOTAL INPUT POWER

POWER SOURCE

REFRIGERANT TYPE

MASTER UNIT+SLAVE UNIT

OUTDOOR UNITMODEL

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

MDS 260BR MDS 280BR MDS 300BR MDS 320B

MDS 120BRM+MDS 150BRS MDS 150BRM+MDS 130BRS MDS 150BRM+MDS 150BRS MDS 160BRM+MDS 160BRS

238,840 255,900 272,960 290,020

70,000 75,000 80,000 85,000

255,900 272,960 290,020 313,904

75,000 80,000 85,000 92,000

21,300 22,800 26,200 27,700

20,900 22,000 23,600 25,500

MDS 260B MDS 280B MDS 300B MDS 320B

MDS 120BM+MDS 150BS MDS 150BM+MDS 130BS MDS 150BM+MDS 150BS MDS 160BM+MDS160BS

238,840 255,900 272,960 290,020

70,000 75,000 80,000 85,000

21,300 22,800 26,200 27,700

380-415/3/50

R-22 R-22 R-22 R-22

3472+3750/7357+7945 3750+3750/7945+7945 3750+3750/7945+7945 3750+3750/7945+7945

2083+2222/4414+4708 2222+2222/4708+4708 2222+2222/4708+4708 2222+2222/4708+4708

68 69 69 69

1840/72.4 1840/72.4 1840/72.4 1840/72.4

2290/90.2 2590/102.0 2590/102.0 2590/102.0

840/33.0 840/33.0 840/33.0 840/33.0

645/1422 710/1565 710/1565 720/1587

Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed

19.05/0.75 19.05/0.75 19.05/0.75 19.05/0.75

41.3/1.625 41.3/1.625 41.3/1.625 41.3/1.625

MDS-BR

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

MDS-BR

HI-FAN

LOW-FAN

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

SIZE

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

MODEL OUTDOOR UNIT MDS 180BR MDS 200BR MDS 220BR MDS 240BR

162,070 170,600 187,660 221,780

47,500 50,000 55,000 65,000

170,600 180,836 197,896 232,016

50,000 53,000 58,000 68,000

14,100 15,200 16,700 19,800

13,200 14,700 16,200 18,500

MDS 180B MDS 200B MDS 220B MDS 240B

162,070 170,600 187,660 221,780

47,500 50,000 55,000 65,000

14,100 15,200 16,700 19,800

380-415/3/50

R-22 R-22 R-22 R-22

3194+3194/6768+6768 3194+3194/6768+6768 3194+3194/6768+6768 3472+3472/7357+7357

1528+1528/3237+3237 1528+1528/3237+3237 1528+1528/3237+3237 2083+2083/4414+4414

66 66 66 68

1840/72.4 1840/72.4 1840/72.4 1840/72.4

1990/78.3 1990/78.3 1990/78.3 1990/78.3

840/33.0 840/33.0 840/33.0 840/33.0

520/1 146 560/1235 560/1235 570/1257

Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed

15.88/0.625 15.88/0.625 19.05/0.75 19.05/0.75

34.9/1.375 34.9/1.375 38.1/1.5 38.1/1.5

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

R-223

R-224

R-22 Indoor SpecificationsMWMD-G

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

IND

OO

R U

NIT

UNIT WEIGHT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

CONDENSATE DRAIN SIZE

POWER SOURCE

REFRIGERANT TYPE/ CONTROL

PIPE CONNECTION

TYPE

SIZE

MWMD 009G MWMD 010G MWMD 015G MWMD 020G MWMD 025G

8500 9600 12300 19100 22200

2.5 2.8 3.6 5.6 6.5

9600 10900 13600 21500 25200

2.8 3.2 4.0 6.3 7.4

130 / 275 142 / 300 163 / 345 231 / 490 397 / 630

106 / 225 118 / 250 135 / 285 193 / 410 231 / 490

83 / 175 94 / 200 104 / 220 160 / 340 208 / 440

40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 43 / 40 / 35 49 / 44 / 42

304 / 12.0 304 / 12.0

799 / 31.5 1062 / 41.8 1062 / 41.8

222 / 8.7 222 / 8.7

10/22.05 16 / 35.27 16 / 35.27

9.52 / 3/8

12.70 / 1/2

20 / 0.79

899 / 35.4

12/26.46

220 - 240 / 1 / 50

R-22 / EXV

DOUBLE LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)

WIRELESS REMOTE CONTROL

260 / 10.2

198 / 7.8

16 / 0.63

FLARE VALVE

6.35 / 1/4

9.52 / 3/8 15.88 / 5/8

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / cfm

l/s / cfm

l/s / cfm

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

MCKD-C

EXTERNAL STATIC PRESSURE (H/M/L)

PIPE CONNECTIONSIZE

AIR FLOW

REFRIGERANT TYPE / CONTROL

CONTROLAIR DISCHARGE

OPERATION

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT (UNIT + PANEL)

CONDENSATE DRAIN SIZE

UNIT DIMENSION

( ) - WITH PANEL

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

IND

OO

R U

NIT

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

MCKD 020C

19100

5.6

21500

6.3

220 - 240 / 1 / 50

R-22 / EXV

212 / 450

203 / 430

194 / 410

0

47 / 46 / 44

23 + 2 / 50.7 + 4.4

15.88 / 5/8

MCKD 015C

12300

3.6

13600

4.0

194 / 410

184 / 390

170 / 360

0

44 / 42 / 41

23.2 / 50.7 + 4.4

12.70 / 1/2

FLARE VALVE

6.35 / 1/4

19.05 / 3/4

4 WAY AUTOMATIC LOUVER (UP & DOWN)

WIRELESS REMOTE CONTROL

570 (640) / 22.4 (25.2)

570 (640) / 22.4 (25.2)

250 (295) / 9.8 (11.6

R-22 / EXV

220 - 240 / 1 / 50

MCKD 010C

9600

2.8

10900

3.2

194 / 410

184 / 390

175 / 370

0

44 / 43 / 42

22 + 2 / 48.5 + 4.4

9.52 / 3/8

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

Pa / in.wg.

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

TYPE

MCMD-E

NOTE:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

EXTERNAL STATIC PRESSURE (H/M/L)

CONDENSATE DRAIN SIZE

POWER SOURCE

REFRIGERANT TYPE / CONTROL

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

UNIT WEIGHT

CONTROLAIR DISCHARGE

OPERATION

UNIT DIMENSION

PIPE CONNECTION 9.52 / 3/8

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

IND

OO

R U

NIT

0

MCMD 028E

27300

8.0

30700

9.0

293 / 620

269 / 570

245 / 520

51 / 48 / 47

28 / 62

MCMD 025E

22200

6.5

25200

7.4

274 / 580

250 / 530

231 / 490

0

50 / 47 / 46

220 - 240 / 1 / 50

R-22 / EXV

AUTOMATIC LOUVER (UP & DOWN)

WIRELESS REMOTE CONTROL

FLARE VALVE

15.88 / 5/8

218 / 8.58

1080 / 42.52

630 / 24.80

19.05 / 3/4

27 / 60

MCMD 020E

19100

5.6

21500

6.3

245 / 520

217 / 460

192 / 406

0

48 / 46 / 43

6.35 / 1/4

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

Pa / in.wg.

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

TYPE

SIZELIQUID

GAS

MCKD-A

EXTERNAL STATIC PRESSURE (H/M/L)

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

PIPE CONNECTION

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

AIR DISCHARGECONTROL

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

CONDENSATE DRAIN SIZE

UNIT DIMENSION

( ) - WITH PANEL

UNIT WEIGHT (UNIT + PANEL)

MODEL INDOOR UNIT

POWER SOURCE

REFRIGERANT TYPE / CONTROL

INDOOR UNIT

IND

OO

R U

NIT

MCKD 020A MCKD 025A MCKD 030A MCKD 040A MCKD 050A

19100 22200 30700 38200 47800

5.6 6.5 9.0 11.2 14.0

21500 25200 34100 42700 54600

6.3 7.4 10.0 12.5 16.0

220 - 240 / 1 / 50

R-22 / EXV

349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040

297 / 630 311 / 660 349 / 740 406 / 860 448 / 950

283 / 600 283 / 600 321 / 680 359 / 760 411 / 870

0 0 0

42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50

31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8

6.35 / 1/4

19.05 / 3/4

FLARE VALVE

9.52 / 3/8

15.88 / 5/8 19.05 / 3/4

820 (930) / 32.2 (36.6)

0

220 - 240 / 1 / 50

R-22 / EXV

4 WAY AUTOMATIC LOUVER (UP & DOWN)

WIRELESS REMOTE CONTROL

335 (378) / 13.2 (14.9)

820 (930) / 32.2 (36.6)

220 - 240 / 1 / 50

R-22 / EXV

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

Pa / in.wg.

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

OPERATION

TYPE

SIZE

HEIGHT

WIDTH

HIGH

DEPTH

MEDIUM

LOW

LIQUID

GAS

R-225

R-226

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).

MDBD

Btu/h

W

Btu/h

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

LIQUID mm/inGAS mm/in

MDBD 080

76400

22400

85300

1700

1444 / 3058

1250 / 2647

1083 / 2294

100 / 0.40

420 / 16.5

25.4 / 1.0

28.6 / 1 1/8

MODEL

AIR FLOW

DEPTH

LOW

CONTROL

UNIT DIMENSION

HEIGHT

INDOOR UNIT

REFRIGERANT CONTROL (EXPANSION DEVICE)

HIGH

MEDIUM

AIR DISCHARGE

OPERATION

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL (H/M/L)

WEIGHT

CONDENSATE DRAIN SIZE

1690 / 66.5

879 / 34.6

100 / 220

PIPE CONNECTIONTYPE

SIZE12.7 / 1/2 12.7 / 1/2

WNOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

IND

OO

R U

NIT

MDBD 100

95500

28000

107500

1480

25000 31500

1750 / 3706

-

-

150 / 0.60

520 / 20.5

1580 / 62.2

57 57

1020 / 40.2

150 / 330

25.4 / 1.0

28.6 / 1 1/8

220 ~ 240 / 1 / 50 380 ~ 415 / 3 / 50

EXV

WIRED CONTROL

DUCTED

FLARE VALVE

R-22

EXTERNAL STATIC PRESSURE (H/M/L)

LIQUID

GAS

LOW

CONTROL

UNIT DIMENSION

HEIGHT

INDOOR UNIT

REFRIGERANT TYPE / CONTROL

HIGH

MEDIUM

AIR DISCHARGE

OPERATION

MODEL

AIR FLOW

SUPER HIGH

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL (H/M/L)

WEIGHT

PIPE CONNECTION

TYPE

SIZE

CONDENSATE DRAIN SIZE

DEPTH

MCCD-C

IND

OO

R U

NIT

MCCD 060C

56000

16.4

63100

18.5

779 / 1650

722 / 1530

675 / 1430

609 / 1290

176/157/137/98(0.71/0.63/0.55/0.39)

55 / 53 / 50 / 47

378 / 14.88

1499 / 59.02

541 / 21.30

62 / 136.69

12.70 / 1/2

MCCD 050C

47800

14.0

54600

16.0

750 / 1590

651 / 1380

604 / 1280

571 / 1210

176/157/137/108(0.71/0.63/0.55/0.43)

53 / 52 / 50 / 47

378 / 14.88

1299 / 51.14

541 / 21.30

54 / 119.05

19.05 / 3/4

FLARE VALVE

R-22 / EXV

DUCTED

WIRED CONTROL

19.05 / 3/4

220 - 240 / 1 / 50

MCCD 040C

38200

11.2

42700

12.5

519 / 1100

500 / 1060

467 / 990

425 / 900

206/176/127/93(0.83/0.71/0.51/0.37)

51 / 49 / 45 / 41

378 / 14.88

1045 / 41.14

541 / 21.30

42 / 92.59

9.52 / 3/8

MCCD 030C

30700

9.0

34100

10.0

425 / 900

392 / 830

359 / 760

335 / 710

206/167/127/88(0.83/0.67/0.51/0.35)

49 / 46 / 42 / 38

378 / 14.88

929 / 36.57

541 / 21.30

39 / 85.98

15.88 / 5/8

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

l/s / CFM

Pa (in.wg.)

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

LIQUID

GAS

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

MODEL INDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

UNIT DIMENSION

HEIGHT

AIR DISCHARGE

HIGH

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

LOW

MEDIUM

IND

OO

R U

NIT

OPERATION

POWER SOURCE

REFRIGERANT TYPE / CONTROL

CONTROL

PIPE CONNECTION

TYPE

SIZE

MCMD-D/C

MCMD 040D MCMD 050D MCMD 062C

Btu/h 38200 47800 56000

kW 11.2 14.0 16.4

Btu/h 42700 54600 63100

kW 12.5 16.0 18.5

V/Ph/Hz

l/s / CFM 477 / 1010 491 / 1040 731 / 1550

l/s / CFM 420 / 890 448 / 950 623 / 1320

l/s / CFM 368 / 780 387 / 820 472 / 1000

dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46

mm/in 285 / 11.2

mm/in 1903 / 74.9

mm/in 680 / 26.8

kg/lb 85 / 187.4

mm/in

mm/in 12.7 / 1/2

mm/in

70 / 154.3

1714 / 67.40

670 / 26.30

249 / 9.80

AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)

WIRELESS REMOTE CONTROL

220 - 240 / 1 / 50

R-22 / EXV

19.05 / 3/4

9.52 / 3/8

FLARE VALVE

19.05 / 3/4

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

MCCD-C

EXTERNAL STATIC PRESSURE (H/M/L)

LIQUID

GAS

MODEL

AIR FLOW

SUPER HIGH

DEPTH

LOW

CONTROL

UNIT DIMENSION

HEIGHT

INDOOR UNIT

REFRIGERANT TYPE / CONTROL

HIGH

MEDIUM

AIR DISCHARGE

OPERATION

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

WIDTH

SOUND PRESSURE LEVEL (H/M/L)

WEIGHT

CONDENSATE DRAIN SIZE

PIPE CONNECTION

TYPE

SIZE15.88 / 5/8

IND

OO

R U

NIT

MCCD 025C

22200

6.5

25200

7.4

-

382 / 810

359 / 760

288 / 610

41/31/18(0.16/0.12/0.07)

40 / 39 / 36

261 / 10.28

1200 / 47.24

411 / 16.18

25 / 55.1

9.52 / 3/8

MCCD 020C

19100

5.6

21500

6.3

-

316 / 670

302 / 640

278 / 590

69/65/42(0.28/0.26/0.17)

38 / 36 / 34

261 / 10.28

1065 / 41.93

411 / 16.18

22 / 48.5

220 - 240 / 1 / 50

R-22 / EXV

DUCTED

WIRED CONTROL

19.05 / 3/4

FLARE VALVE

MCCD 015C

12300

3.6

13600

4.0

-

241 / 510

208 / 440

170 / 360

49/39/20(0.20/0.16/0.08)

37 / 34 / 29

21 / 46.3

12.70 / 1/2

261 / 10.28

905 / 35.63

411 / 16.18

6.35 / 1/4

MCCD 010C

9600

2.8

10900

3.2

-

142 / 300

123 / 260

104 / 220

49/39/29(0.20/0.16/0.12)

33 / 30 / 26

17 / 37.5

9.52 / 3/8

261 / 10.28

765 / 30.12

411 / 16.18

Btu/h

kW

Btu/h

kW

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

l/s / CFM

Pa (in.wg.)

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

mm/in

R-410A1

R-410A2

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

COOLING

HEATING

HEIGHT

WIDTH

DEPTH

LIQUID

GASSIZE

NOMINAL TOTAL INPUT POWER

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE (LIQUID/GAS)

NOMINAL TOTAL INPUT POWER

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

MODEL OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

5MDS 070BR

64,800

19,000

71,600

21,000

6,000

5,900

5MDS 070B

64,800

19,000

6,000

380-4150/ 3/ 50

R-22

1775 / 3765

62

1349 / 53.1

1058 / 41.6

430 / 16.9

135 / 297

FLARE / BRAZE

9.52 / 3/8

15.88 / 5/8

5MDS 060BR

51,100

15,000

59,700

17,500

4,700

4,400

5MDS 060B

51,100

15,000

4,700

380-415 / 3 / 50

R-22

1665 / 3530

60

1247 / 49.1

1058 / 41.7

430 / 16.9

130 / 287

FLARE / BRAZE

9.52 / 3/8

15.88 / 5/8

5MDS 050BR

46,000

13,500

51,100

15,000

4,400

4,300

5MDS 050B

46,000

13,500

4,400

380-415 / 3 / 50

R-22

1220 / 2590

59

1044 / 41.4

1058 / 41.7

430 / 16.9

120 / 265

FLARE / BRAZE

9.52 / 3/8

15.88 / 5/8

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

R-410A Outdoor Specification5MDS-BR

5MDS 080BR 5MDS 100BR 5MDS 120BR 5MDS 140BR 5MDS 160BR

Btu/h 85,300 95,536 112,596 129,656 143,304

W 25,000 28,000 33,000 38,000 42,000

Btu/h 95,536 109,184 126,244 143,304 160,364

W 28,000 32,000 37,000 42,000 47,000

COOLING W 7,200 8,000 9,700 11,300 12,900

HEATING W 7,000 7,900 9,400 10,900 11,900

5MDS 080B 5MDS 100B 5MDS 120B 5MDS 140B 5MDS 160B

Btu/h 85,300 95,536 112,596 129,656 143,304

W 25,000 28,000 33,000 38,000 42,000

W 7,200 8,000 9,700 11,300 12,900

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50

R-410A R-410A R-410A R-410A R-410A

HI-FAN l/s / cfm 3056 / 6474 3056 / 6474 3055 / 6474 3333 / 7063 3333 / 7063

LOW-FAN l/s / cfm 1528 / 3237 1528 / 3237 1528 / 3237 2083 / 4414 2083 / 4414

dB(A) 56 57 60 60 60

HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4

WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8 1290 / 50.8

DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0

kg/lb 290 / 639 300 / 661 305 / 672 350 / 771 360 / 793

Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed

LIQUID mm/in 9.52 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2

GAS mm/in 22.2 / 7/8 22.2 / 7/8 22.2 / 7/8 28.6 / 11/8 28.6 / 11/8

kg/lb 7.9 / 17.4 10.0 / 22.0 10.6 / 23.4 12.2 / 26.9 13.4 / 29.5

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

MODEL OUTDOOR UNIT

TYPE (LIQUID/GAS)

SIZE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

MODEL

5MDS-BR

5MDS 260BR

5MDS 120BRM + 5MDS 140BRS

242,252

71,000

266,136

78,000

COOLING 21,000

HEATING 20,300

5MDS 260B

242,252

71,000

21,000

380 - 415 / 3 / 50

R-410A

HI-FAN 3056 + 3333 / 6474 + 7063

LOW-FAN 1528 + 2083 / 3237 + 4414

62

HEIGHT 1840 / 72.4

WIDTH 2290 / 90.2

DEPTH 840 / 33.0

655 / 1444

Flare / Brazed

LIQUID 15.9 / 5/8GAS 34.9 / 13/4

22.8 / 50.3

OUTDOOR UNIT

MODELMASTER UNIT+SLAVE UNIT

MODELMASTER UNIT+SLAVE UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUTPOWER

UNIT DIMENSION

POWER SOURCE

REFRIGERANT TYPE

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

OU

TD

OO

R U

NIT

UNIT WEIGHT

PIPECONNECTION

TYPE (LIQUID/GAS)

SIZE

REFRIGERANT CHARGE

AIR FLOW

SOUND PRESSURE LEVEL

5MDS 180BR

-

160,364

47,000

180,836

53,000

14,500

13,800

5MDS 180B

-

160,364

47,000

14,500

380 - 415 / 3 / 50

R-410A

3472 / 7357

2222 / 4708

61

1840 / 72.4

1290 / 50.8

840 / 33.0

370 / 816

Flare / Brazed

12.7 / 1/2

28.6 / 11/814.8 / 32.6

5MDS 200BR

-

180,836

53,000

201,308

59,000

16,200

14,700

5MDS 200B

-

180,836

53,000

16,200

380 - 415 / 3 / 50

R-410A

61

1840 / 72.4

1990 / 78.3

840 / 33.0

590 / 1301

Flare / Brazed

15.9 / 5/8

28.6 / 11/818.0 / 39.7

5MDS 220BR

-

197,896

58,000

221,780

65,000

17,700

16,900

5MDS 220B

-

197,896

58,000

17,700

380 - 415 / 3 / 50

R-410A

62

1840 / 72.4

1990 / 78.3

840 / 33.0

590 / 1301

Flare / Brazed

15.9 / 5/8

28.6 / 11/819.6 / 43.2

5MDS 240BR

-

218,368

64,000

242,252

71,000

19,800

18,500

5MDS 240B

- -

218,368

64,000

19,800

380 - 415 / 3 / 50

R-410A

62

1840 / 72.4

1990 / 78.3

840 / 33.0

600 / 1323

Flare / Brazed

15.9 / 5/8

28.6 / 11/821.5 / 47.4

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

kg/lb

3056 x 2 / 6474 x 2 3056 x 2 / 6474 x 22778 x 2 / 5886 x 2

1528 x 2 / 3237 x 2 1528 x 2 / 3237 x 2 1528 x 2 / 3237 x 2

5MDS-BR

5MDS 360BR

5MDS 180BRM + 5MDS 180BRS

Btu/h 320,728

W 94,000

Btu/h 361,672

W 106,000

COOLING W 29,000

HEATING W 27,600

5MDS 360B

5MDS 180BM + 5MDS 180BS

Btu/h 320,728

W 94,000

W 29,000

V/Ph/Hz 380 - 415 / 3 / 50

R-410A

HI-FAN l/s / cfm

LOW-FAN l/s / cfm

dB(A) 63

HEIGHT mm/in 1840 / 72.4

WIDTH mm/in 2590 / 102.0

DEPTH mm/in 840 / 33.0

kg/lb 740 / 1631

Flare / Brazed

LIQUID mm/in 19.1 / 3/4GAS mm/in 34.9 / 13/4

kg/lb 34.0 / 75.0

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

UNIT DIMENSION

UNIT WEIGHT

PIPECONNECTION

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUTPOWER

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

5MDS 340BR

5MDS 180BRM + 5MDS 160BRS

303,668

89,000

341,200

100,000

27,400

25,700

5MDS 340B

5MDS 180BM + 5MDS 160BS

303,668

89,000

27,400

380 - 415 / 3 / 50

R-410A

3472 + 3333 / 7357 + 7063

2222 + 2083 / 4708 + 4414

3472 x 2 / 3753 x 2

2222 x 2 / 4708 x 2

63

1840 / 72.4

2590 / 102.0

840 / 33.0

730 / 1609

Flare / Brazed

19.1 / 3/4

34.9 / 13/434.0 / 75.0

5MDS 320BR

5MDS 180BRM + 5MDS 140BRS

290,020

85,000

324,140

95,000

25,800

24,700

5MDS 320B

5MDS 180BM + 5MDS 140BS

290,020

85,000

25,800

380 - 415 / 3 / 50

R-410A

3472 + 3333 / 7357 + 7063

2222 + 2083 / 4708 + 4414

63

1840 / 72.4

2590 / 102.0

840 / 33.0

720 / 1587

Flare / Brazed

15.9 / 3/4

34.9 / 13/432.0 / 92.6

5MDS 300BR

5MDS 120BRM + 5MDS 180BRS

272,960

80,000

296,844

87,000

24,200

23,200

5MDS 300B

5MDS 120BM + 5MDS 180BS

272,960

80,000

24,200

380 - 415 / 3 / 50

R-410A

3056 + 3472 / 6474 + 7357

1528 + 2222 / 3237 + 4708

62

1840 / 72.4

2290 / 90.2

840 / 33.0

675 / 1488

Flare / Brazed

15.9 / 5/8

34.9 / 13/430.0 / 66.1

5MDS 280BR

5MDS 120BRM + 5MDS 160BRS

255,900

75,000

279,784

82,000

22,600

21,300

5MDS 280B

5MDS 120BM + 5MDS 160BS

255,900

75,000

22,600

380 - 415 / 3 / 50

R-410A

3056 + 3333 / 6474 + 7063

1528 + 2083 / 3237 + 4414

62

1840 / 72.4

2290 / 90.2

840 / 33.0

665 / 1466

Flare / Brazed

15.9 / 5/8

34.9 / 13/424.0 / 52.9

5MDS-BR

R410A3

R410A4

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.

IND

OO

R U

NIT

M5WMD-G

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

INDOOR MODEL

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

SIZE

POWER SOURCE

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

UNIT DIMENSION

AIR FLOW

PIPE CONNECTION

TYPE

M5WMD 009G M5WMD 010G M5WMD 015G

Btu/h 8500 9600 12300

W 2500 2800 3600

Btu/h 9600 10900 13600

W 2800 3200 4000

24 26 29W

V/Ph/Hz

l/s / cfm 130 / 275 142 / 300 163 / 345

l/s / cfm 106 / 225 118 / 250 135 / 285

l/s / cfm 83 / 175 94 / 200 104 / 220

dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29

mm/in

mm/in 799 / 31.5

mm/in

kg/lb 10/22.05

mm/in

mm/in 12.7 / 1/2

220-240/1/50

FLARE VALVE

9.5 / 3/8

12/26.46

899 / 35.4

6.4 / 1/4

260 / 10.2

198 / 7.8

IND

OO

R U

NIT

M5WMD-G

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

INDOOR MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

POWER SOURCE

AIR FLOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

M5WMD 025G

Btu/h 22200

W 6500

Btu/h 25200

W 7400

66W

V/Ph/Hz

l/s / cfm 397 / 630

l/s / cfm 231 / 490

l/s / cfm 208 / 440

dBA 49 / 44 / 42

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

16 / 35.27

FLARE VALVE

6.4 / 1/4

15.9 / 5/8

220-240/1/50

304 / 12.0

1062 / 41.8

222 / 8.7

M5WMD 020G

19100

5600

21500

6300

47

231 / 490

193 / 410

160 / 340

43 / 40 / 35

12.7 / 1/2

R410A Indoor Specifications

NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.

COOLING

HEATING

HI-FAN

LOW-FAN

HEIGHT

WIDTH

DEPTH

LIQUID

GAS

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

REFRIGERANT CHARGE

POWER SOURCE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

TYPE (LIQUID/GAS)

SIZE

UNIT DIMENSION

UNIT WEIGHT

PIPECONNECTION

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTALINPUT POWER

NOMINAL TOTAL INPUT POWER

MODELOUTDOOR UNIT

5MDS 440BR

5MDS 240BRM + 5MDS 200BRS

399,204

117,000

443,560

130,000

36,000

33,200

5MDS 440B

5MDS 240BM + 5MDS 200BS

399,204

117,000

36,000

380 - 415 / 3 / 50

R410a

65

3056 x 4 / 6474 x 4

1528 x 4 / 3237 x 4

1840 / 72.4

3990 / 129.5

840 / 33.01190 / 2624

Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

44.0 / 97.0

5MDS 420BR

5MDS 240BRM + 5MDS 180BRS

378,732

111,000

423,088

124,000

34,300

32,300

5MDS 420B

5MDS 240BM + 5MDS 180BS

378,732

111,000

34,300

380 - 415 / 3 / 50

R410a

65

3056 x 2 + 3472 / 6474 x 2 + 7357

1528 x 2 + 2083 / 3237 x 2 + 4708

1840 / 72.4

3290 / 129.5

840 / 33.0970 / 2138

Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

42.0 / 92.6

5MDS 400BR

5MDS 240BRM + 5MDS 160BRS

361,672

106,000

402,616

118,000

32,700

30,400

5MDS 400B

5MDS 240BM + 5MDS 160BS

361,672

106,000

32,700

380 - 415 / 3 / 50

R410a

65

3056 x 2 + 3333 / 6474 x 2 + 7063

1528 x 2 + 2083 / 3237 x 2 + 4414

1840 / 72.4

3290 / 129.5

840 / 33.0960 / 2116

Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

40.0 / 88.2

5MDS 380BR

5MDS 240BRM + 5MDS 140BRS

348,024

102,000

385,556

113,000

31,100

29,400

5MDS 380B

5MDS 240BM + 5MDS 140BS

348,024

102,000

31,100

380 - 415 / 3 / 50

R410a

64

1840 / 72.4

3056 x 2 + 3333 / 6474 x 2 + 7063

1528 x 2 + 2083 / 3237 x 2 + 4414

3290 / 129.5

840 / 33.0950 / 2094

Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

38.0 / 83.4

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/in

mm/inkg/lb

mm/in

mm/in

kg/lb

5MDS-BR

COOLING

HEATING

HI-FAN

LOW-FAN

HEIGHT

WIDTHDEPTH

LIQUIDGAS

NOMINAL COOLING CAPACITY

MODELOUTDOOR UNIT

MASTER UNIT+SLAVE UNIT

REFRIGERANT CHARGE

REFRIGERANT TYPE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

UNIT WEIGHT

PIPECONNECTION

TYPE (LIQUID/GAS)

SIZE

NOMINAL HEATING CAPACITY

NOMINAL TOTALINPUT POWER

POWER SOURCE

MODELOUTDOOR UNITMASTER UNIT+SLAVE UNIT

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

5MDS 500BR

5MDS 250BRM + 5MDS 250BRS

457,208

134,000

504,976

148,000

41,800

39,000

5MDS 500B5MDS 250BM + 5MDS 250BS

457,208

134,000

41,800

380 - 415 / 3 / 50

R410a

65

1840 / 72.4

3990 / 129.5840 / 33.0

1220 / 2690Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

3056 x 4 / 6474 x 4

1528 x 4 / 3237 x 4

50.0 / 110.2

5MDS 480BR

5MDS 240BRM + 5MDS 240BRS

436,736

128,000

484,504

142,000

39,600

37,000

5MDS 480B5MDS 240BM + 5MDS 240BS

436,736

128,000

39,600

380 - 415 / 3 / 50

R410a

65

1840 / 72.4

3990 / 129.5840 / 33.0

1200 / 2646Flare / Brazed

19.1 / 3/4

41.3 / 1 5/8

3056 x 4 / 6474 x 4

1528 x 4 / 3237 x 4

48.0 / 105.8

5MDS 460BR

5MDS 240BRM + 5MDS 220BRS

416,264

122,000

464,032

136,000

37,500

35,400

5MDS 460B5MDS 240BM + 5MDS 220BS

416,264

122,000

37,500

380 - 415 / 3 / 50

R410a

65

1840 / 72.4

3990 / 129.5840 / 33.0

1190 / 2624Flare / Brazed

19.1 / 3/4

41.3 / 1 5/846.0 / 101.4

3056 x 4 / 6474 x 4

1528 x 4 / 3237 x 4

Btu/h

W

Btu/h

W

W

W

Btu/h

W

W

V/Ph/Hz

l/s / cfm

l/s / cfm

dB(A)

mm/in

mm/inmm/inkg/lb

mm/inmm/inkg/lb

5MDS-BR

R-410A5

R-410A6

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) FOR M5CKD 020/025 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA. FOR M5CKD 030/040/050 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.

IND

OO

R U

NIT

M5CKD-A

LIQUID

GAS

NOMINAL TOTAL INPUT POWER

HIGH

MEDIUM

HEIGHT

SOUND PRESSURE LEVEL (H/M/L)

DEPTH

PIPE CONNECTION

TYPE

SIZE

INDOOR MODEL

LOW

POWER SOURCE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

WIDTH

AIR FLOW

WEIGHT (UNIT + PANEL)

UNIT DIMENSION ( ) - WITH PANEL

M5CKD 020A M5CKD 025A M5CKD 030A M5CKD 040A M5CKD 050A

19100 22200 30700 38200 47800

5600 6500 9000 11200 14000

21500 25200 34100 42700 54600

6300 7400 10000 12500 16000

35 45 60 83 120

349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040

297 / 630 311 / 660 349 / 740 406 / 860 448 / 950

283 / 600 283 / 600 321 / 680 359 / 760 411 / 870

42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50

31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8

6.4 / 1/4 6.4 / 1/4 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8

12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8

820 (930) / 32.2 (36.6)

220-240/1/50

335 (378) / 13.2 (14.9)

820 (930) / 32.2 (36.6)

FLARE VALVE

Btu/h

W

Btu/h

W

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

M5CKD-C

LIQUID

GAS

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.

UNIT WEIGHT (UNIT + PANEL)

PIPE CONNECTION

TYPE

SIZE

DEPTH

LOW

UNIT DIMENSION ( ) - WITH PANEL

IND

OO

R U

NIT

POWER SOURCE

AIR FLOW

HIGH

SOUND PRESSURE LEVEL (H/M/L)

HEIGHT

WIDTH

INDOOR MODEL

MEDIUM

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

M5CKD 010C M5CKD 015C M5CKD 020C

9600 12300 19100

2800 3600 5600

10900 13600 21500

3200 4000 6300

16 18 22

189 / 400 194 / 410 212 / 450

184 / 390 184 / 390 203 / 430

175 / 370 170 / 360 194 / 410

44 / 43 / 42 44 / 42 / 41 47 / 46 / 44

22 + 2 / 48.5 + 4.4 23.2 / 50.7 + 4.4 23 + 2 / 50.7 + 4.4

FLARE VALVE

6.4 / 1/4

9.5 / 3/8 12.7 / 1/2 12.7 / 1/2

220 - 240 / 1 / 50

250 (295) / 9.8 (11.6)

570 (640) / 22.4 (25.2)

570 (640) / 22.4 (25.2)

FLARE VALVE

Btu/h

W

Btu/h

W

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.

M5CMD-E

LIQUID

GAS

LOW

NOMINAL COOLING CAPACITY

SOUND PRESSURE LEVEL (H/M/L)

AIR FLOW

HIGH

MEDIUM

NOMINAL HEATING CAPACITY

POWER SOURCE

PIPE CONNECTION

TYPE

SIZE

UNIT WEIGHT

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

IND

OO

R U

NIT

NOMINAL TOTAL INPUT POWER

UNIT DIMENSION

M5CMD 015E M5CMD 020E M5CMD 025E M5CMD 028E

12300 19100 22200 27300

3600 5600 6500 8000

13600 21500 25200 30700

4000 6300 7400 9000

79 101 109 150

240 / 508 245 / 520 274 / 580 293 / 620

182 / 386 217 / 460 250 / 530 269 / 570

165 / 350 192 / 406 231 / 490 245 / 520

46 / 38 / 35 50 / 43 / 41 53 / 51 / 49 56 / 51 / 44

26 / 57 27 / 60 27 / 60 28 / 62

9.52 / 3/8

218 / 8.58

1080 / 42.52

630 / 24.80

220 - 240 / 1 / 50

FLARE VALVE

12.7 / 1/2

6.35 / 1/4

15.9 / 5/8

Btu/h

W

Btu/h

W

W

V/Ph/Hz

l/s / CFM

l/s / CFM

l/s / CFM

dBA

mm/in

mm/in

mm/in

kg/lb

mm/in

mm/in

IND

OO

R U

NIT

M5CMD-D/C

LIQUID

GAS

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.

PIPE CONNECTION

TYPE

SIZE

SOUND PRESSURE LEVEL (H/M/L)

UNIT WEIGHT

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

AIR FLOW

HIGH

MEDIUM

LOW

NOMINAL TOTAL INPUT POWER

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

POWER SOURCE

INDOOR MODEL M5CMD 040D M5CMD 050D M5CMD 062C

Btu/h 38200 47800 56000

W 11200 14000 16400

Btu/h 42700 54600 63100

W 12500 16000 18500

W 153 171 327

V/Ph/Hz

l/s / CFM 477 / 1010 491 / 1040 732 / 1550

l/s / CFM 420 / 890 448 / 950 623 / 1320

l/s / CFM 368 / 780 387 / 820 472 / 1000

dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46

mm/in 285 / 11.2

mm/in 1903 / 74.9

mm/in 680 / 26.8

kg/lb 85 / 187.4

mm/in

mm/in 19.1 / 3/4

670 / 26.30

220 - 240 / 1 / 50

70 / 154.3

249 / 9.80

FLARE VALVE

9.52 / 3/8

15.9 / 5/8

1714 / 67.40

Btu/h 9600 12300 19100 22200 27300

W 2800 3600 5600 6500 8000

Btu/h 10900 13600 21500 25200 30700

W 3200 4000 6300 7400 9000

W 65 96 135 152 300

V/Ph/Hz

l/s / CFM - - - - 401 / 850

l/s / CFM 142 / 300 241 / 510 330 / 700 345 / 730 382 / 810

l/s / CFM 123 / 260 208 / 440 321 / 680 340 / 720 363 / 770

l/s / CFM 104 / 220 170 / 360 293 / 620 274 / 580 335 / 710

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 49 / 39 / 29(0.2 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.3 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.4 / 0.3 / 0.3 / 0.2)

49 / 39 / 20 64 / 58 / 34 55 / 39 / 29 98 / 78 / 68 / 59

dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 44 / 41 / 38 / 34

mm/in 285 / 11.22

mm/in 765 / 30.12 905 / 35.63 1065 / 41.93 1200 / 47.24 1007 / 39.65

mm/in 600 / 23.62

kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 38 / 84

LIQUID mm/in 9.5 / 3/8

GAS mm/in 9.5 / 3/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.

220 - 240 / 1 / 50

PIPE CONNECTION

TYPE

SIZE15.9 / 5/8

WEIGHT

UNIT DIMENSION

LOW

SOUND PRESSURE LEVEL (SH/H/M/L)

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

HIGH

MEDIUM

NOMINAL TOTAL INPUT POWER

POWER SOURCE

AIR FLOW

SUPER HIGH

WIDTH

HEIGHT

DEPTH

INDOOR MODEL

FLARE VALVE

411 / 16.18

6.4 / 1/4

12.7 / 1/2

261 / 10.28

Btu/h 30700 34100 38200 47800 56000

W 9000 10000 11200 14000 16400

Btu/h 34100 38200 42700 54600 63100

W 10000

460

11200 12500

510

16000 18500

W 503 515 659

V/Ph/Hz

l/s / CFM 604 / 1280 675 / 1430 812 / 1720

l/s / CFM 547 / 1160 623 / 1320 732 / 1550

l/s / CFM 496 / 1050 580 / 1230 632 / 1340

l/s / CFM 434 / 920 533 / 1130 552 / 1170

EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 118 / 96 / 78 / 61 (0.5 / 0.4 / 0.3 / 0.2) (0.5 / 0.4 / 0.3 / 0.2) (0.6 / 0.5 / 0.4 / 0.3) (0.6 / 0.5 / 0.4 / 0.3)

147 / 126 / 109 / 92 147 / 120 / 90 / 69

dBA 52 / 49 / 48 / 45

566 / 1200

486 / 1030

406 / 860

349 / 740

120 / 86 / 64 / 45(0.5 / 0.3 / 0.3 / 0.2)

52 / 49 / 48 / 45 54 / 53 / 52 / 51

628 / 1330

571 / 1210

491 / 1040

425 / 900

120 / 98 / 74 / 54

51 / 49 / 45 / 41 54 / 52 / 50 / 46

mm/in 378 / 14.88 305 / 12.0 378 / 1488 378 / 14.9 378 / 14.9

mm/in 929 / 36.57 1302 / 51.3 1045 / 14.14 1299 / 51.1 1499 / 59.0

mm/in 514 / 21.3 638 / 25.1 541 / 21.3 541 / 21.3 541 / 21.3

kg/lb 39 / 86 41 / 90 42 / 92.6 54 / 119 62 / 137

LIQUID mm/in

GAS mm/in 19.05 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.

220 - 240 / 1 / 50

AIR FLOW

LOW

POWER SOURCE

HIGH

PIPE CONNECTION

TYPE

SIZE

DEPTH

WEIGHT

UNIT DIMENSION

9.5 / 3/8

15.9 / 5/8

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

MEDIUM

SUPER HIGH

NOMINAL TOTAL INPUT POWER

HEIGHT

SOUND PRESSURE LEVEL (SH/H/M/L)

WIDTH

INDOOR MODEL

FLARE VALVE

IND

OO

R U

NIT

IND

OO

R U

NIT

M5CCD-C

M5CCD 010C M5CCD 015C M5CCD 020C M5CCD 025C M5CCD 028C

M5CCD -C

M5CCD 030C M5CCD 038C M5CCD 040C M5CCD 050C M5CCD 060C

R-410A7