A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.
Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.
For the most up-to-date product information, please go to www.mcquay.com.
©2009 McQuay International +1 (800) 432-1342 www.mcquay.com
Manufacturing Plant
Minneapolis
Faribault
OwatonnaStauntan
Mexico City
Auburn
SuzhouWuhan
Shenzhen
Kuala Lumpur
Jakarta
Americas• USA • Puerto Rico • Mexico • Paraguay • Uruguay • Guadaloupe
Oceania• Australia • Fiji • New Zealand • Papua New Guinea
Middle East & Africa• Jordan • Lebanon • Oman • Qatar • Saudi Arabia • Bahrain • Morocco • Iraq • U.A.E. • Mauritius • South Africa • Kenya • Madagascar • Ghana • Nigeria • Tanzania
Europe• Albania • England • Greece • Hungary • Italy • Norway • Poland • Portugal • Russia • Spain • Belgium • Tunisia • Croatia • Cyprus • Lithuania • Malta • Turkey • Czech Republic Asia• Cambodia • China • Philippines • Hong Kong • India • Indonesia • Maldives • Myanmar • Nepal • Singapore • Thailand • Vietnam • Pakistan
Cramlington
Cecchina
Multi Digital ScrollSystem Features 4Application 12Outdoor Features 14Indoor Features 16Integrated Software 23Controller And Accessories 24Project References 25
SpecificationsR-22 Outdoor R-22 - 1R-22 Indoor R-22 - 3R-410A Outdoor R-410A - 1R-410A Indoor R-410A - 4
1
5MDS 080/100/120/140/160/180BR
5MDS 050/060/070A/AR
25.0 - 47.0 28.0 - 53.0
5MDS 380/400/420BR
5MDS 200/220/240/260/280/300/320/340/360BR 53.0 - 94.0
102.0 - 111.0
59.0 - 106.0
113.0 - 124.0
5MDS 440/460/480/500BR 117.0 - 134.0 130.0 - 148.0
Model RangeCooling
Capacity (kW)Heating
Capacity (kW)
Model RangeCooling
Capacity (kW)Heating
Capacity (kW)
8.5 - 18.0
MDS 080/100/120/150B/BR
MDS 180/200/220/240/260/280/300/320B/BR
24.5 – 40.0
9.0 - 20.0
13.5 – 19.0 15.0 – 21.0
26.0 – 43.0
47.5 – 85.0 50.0 – 92.0
MDS 030/040/050/060/070A/AR
Split Type IndoorModel Range Cooling
Capacity (kW)Heating
Capacity (kW)R-410AR-22
MWM-G
MCK-A
MCK-C
MCM-E
MCM-D
MCC-C
MDB
HORIZONTALDISCHARGE
VERTICALDISCHARGE
VERTICALDISCHARGE
HORIZONTAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
VERTICAL DISCHARGE
2.5 - 6.5
5.6 - 14.0
2.8 - 5.6
5.6 - 8.0
11.2 - 16.4
2.8 - 7.4
6.3 - 16.0
3.2 - 6.3
6.3 - 9.0
2.8 - 16.4 3.2 - 18.5
22.4 – 25.0 28.0 – 31.5
2 3
MDS R-410A Condensing Unit
MDS R-22 Condensing Unit
12.5 - 18.5
MORE ECONOMICAL OPERATIONWith higher IPLV, MDS is able to operate with lower power consumption.
4
NO CONVERSION LOSTComparing to the traditional inverter drive air-conditioner, MDS has eliminated the possibility of lost of energy during the conversion of power signal.
BETTER DEHUMIDIFYING PERFORMANCEThe continuously operating compressor in the MDS system provides better dehumidifying performance, and hence able to reduce the indoor RH to a more desired level. With lower RH in the interior, the growth of the bacteria and fungus are inhabited.
BETTER PART LOAD EFFICIENCYMost air-conditioning system operates in the 30%~70% region. Integrated with the digital scroll compressor technology, MDS is capable to modulate its supply capacity to meet most indoors requirement closely. This modulating capability enable the MDS system to offer higher IPLV (Integrated Part Load Value).
Utilising the digital scroll compressor technology, the McQuay Multi Digital ScrollSystem (MDS) is seen as the next generation products for high-efficiency air conditioning.
AC Converted FrequencyInverter
Compressor
Capacity Controller
TransformationConcumption = 0%
MotorConsumption
= 5-10%
DCAC DCTransformer
AC DCFrequency Conversion
T rad i t i ona l I n ve r t e r Sys tem
DigitalCompressorAC PWM valve
Capacity Controller
TransformationComsumption = 0%
MDS Sys tem
5th
7th
11th
13th
17th
19th
0 1 2 3 4 5
MDS System EMC Standard Inverter System
EMC comparison during development stage
Temp.
Time1 2 3 4
Tr
Ts
The temperature fluctuation range of traditional air conditioning system
The temperature fluctuation range of MDS system
Tr = Room TemperatureTs = Set Temperature
5
MDS 100B System
100%
5%
FixedCompressorOperating
DigitalOperating
DigitalOperating
Loading Unloading
MDS100BR IPLV Testing
2
2.5
3
3.5
4
4.5
0 20 40 60 80 100
IPLV(C) = 3.56
IPLV(H) = 3.71
Capacity (%)
Cooling
Heating
COP (W/W)
IPLV Testing Condition:Cooling cycle: 27°C DB / 19°C WB indoorand 27°C DB outdoorHeating cycle:20°C DB / 15°C WB indoorand 7°C DB / 6°C WB outdoor
IMPROVED ELECTROMAGNETIC COMPATIBILITYUnlike variable speed compressors air conditioners, MDS runs at a constant speed throughout the operation, thus there is lower electromagnetic interference. This unique feature reduces the need for expensive electromagnetic suppression electronics required to ensure electromagnetic compatibility.
TIGHTER TEMPERATURE CONTROLThe ambient of the outdoor and indoor change frequently and this will affect the indoor cooling and heating load. With MDS system, using an improved control algorithm, the temperature is kept closer to the set temperature.
6 7
Comparing to conventional chilled water system, MDS required far less equipment. Boilers, cooling tower are things in the past with MDS. Thus, MDS is a better solution for new projects or even retrofit purposes.
Conventional ChilledWater System
MDS System
PERFORMANCE CHOICESOLUTIONS
Temperature °C
43°CDB
0°CDB
16°CWB
-15°CWDB
50
40
30
20
10
0
-10
-20
Cooling Cycle Heating Cycle
WIDER OPERATING RANGEMDS system undergo rigorous test to ensure that the system can operate within -15ºC to 43ºC.
INTELLIGENT CAPACITY MODULATIONThe MDS system operates in a stepless capacity modulation ranging from 10~100%. The modulation will closely match the demand capacity whereby contributing higher IPLV.
t1 t2Time
InitialTemperature
SettingTemperature
Traditional Air ConditioningMDS System
RAPID COOLING AND HEATING CAPABILITYThe improved heat-exchanger combining with the better efficiency compressor promotes rapid exchange between refrigerant and air, ensuring set temperature to be achieved faster compared to traditional air-conditioning system.
Height15m
PipingLength150m
Height50m
LONG PIPING DESIGN FOR FLEXIBILITYPiping length between outdoor and indoor unit can be extended up to 150 meters. The height between outdoor unit and indoor unit can be extended up to 50 meters. The height difference between indoor units can be as high as 15 meters. This greatly reduces constraint and offers more flexibility in system design.
The refnet joint is provided by the factory in accordance with different indoor units, which will reduce the work force at site.
Only a common 2-core, screen cable wire is required to enable communication between outdoor and indoors.
EASIER INSTALLATIONIn-house designed piping joints and wiring connection make it possible to install MDS system faster and easier.
BETTER PLACE UTILISATIONMDS uses the single outdoor multiple indoors combination. This concept has greatly reduced outdoor units and enhances flexibility during installation.
ALARM AND DIAGNOSIS SYSTEMThe MDS system is built in with an alarm system, alerting owners or users for abnormal operation.A user-friendly diagnosis system helps to identify the problems, ensuring continuous operation of the MDS system.
AUTOAUTO
FLOOR BY FLOOR INSTALLATION*The optional outdoor fan with external static pressure of 50Pa is suitable for short-discharge ductwork application. With this feature, an outdoor unit can be placed on each floor, thus allowing installation to be performed floor by floor.* Please contact your local sales office for more information.
VARIETY OF INDOORSThe MDS indoors come with a variety of design and capacity which can be selected to suit most air conditioning needs.
8 9
ADAPTS EASIER TO ANY FLOOR PLANThe wide indoor models can meet the needs of building size and interior design easier. Incorporate with the flexible piping design, the MDS system is suitable for most type of floor layout and various applications.
10 11
AUTO-RANDOM RESTARTAfter power failure, the MDS system will automatically restart operation base on the last state memory. Setting of the unit will not be lost, thus eliminating the needs for re-programming.
CENTRAL CONTROL SYSTEMThe MDS System Management Software is designed with user-friendly interface, enable simple monitoring and control of the system via a computer.
MDS-B series is capable to connect up to 48 units of indoors. Total indoor units capacity can range from 50% to 120% of the outdoor capacity.
LARGE CAPACITY
With all these advantages, it is very clear that MDS is a better solution for centralised air-condition system. What would be the consideration factor to select MDS? Here are some of the main consideration factors and examples.
HospitalConsideration:• Places that require low or no EMC interference • Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
OfficesConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Location for outdoor is limited• Centralized Control
Department Store / RestaurantConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
12 13
House / Apartment / CondominiumConsideration:• Location for outdoor is limited.• Various type of indoor unit with separate temperature requirement.• Heat load of the same air-conditioned area varies
Exhibition / Concert HallConsideration:• Heat load of the same air-conditioned area varies.• Various type of indoor unit with separate temperature requirement • Centralized Control
Factor 1Location for outdooris limited. MDS can be used due to the ability to couple multiple indoors with only 1 outdoor. Better space utilization.
Factor 2Various type of indoor unit with separate temperature requirementMDS system can be couple with various type of indoors. Each indoor can be design to supply to a specific area only and the temperature setting is base on individual indoor setting.
Factor 3Heat load of the same air-conditioned area variesMDS is able to match the indoor load requirement with its part loading capability.
Factor 5Places that require low or no EMC interferenceThe MDS modulation is control by mechanical parts. No change in power supply (frequency or current), thus lower electromagnetic interference.
Factor 4Centralized ControlMDS outdoors and indoors can be linked together and control using the MDS Control & Monitoring Software. The software can also perform scheduling of the indoor units base on the operating duration.
RELIABLE TECHNOLOGYMDS system adopts the advantaged capacity modulation technology to reduce the control devices, which reduce the malfunction odds mostly.
• MDS system has better oil return performance even at low capacities, which will make sure that all of the removable parts of the compressor can be lubricated and cooled down.
• It reduces the start/stop times, which will reduce the attack to the electricity supply net.
• The PWM (Pulse Width Modulation) valve has the longevity of 40 million times.
• The design is simple and there is no requirment for bypass valve.
SMALL FOOTPRINTThe outdoor unit of MDS system is designed as package, the structure occupies less space and is easier to move.
The brain of the MDS system is the compressor which is incorporated in the outdoor condensing unit.With this technology, the outdoor is constructed in a uniform and solid design and focusing on smaller footprint to provide better space utilisation.
Unique Return Oil Technology
UNIFORM DESIGNThe outdoor units can be located on the rooftop. The uniform outlook and dimension allows side by side installation.
QUIET OPERATIONThe condensing unit utilises an advanced spiral fan blades. The smooth material and fan blade design help to reduce the turbulent flow and thus reduce the air flow noise.
14 15
WMWall MountedG SeriesMWMD 009/010/015/020/025 GM5WMD 009/010/015/020/025 GCooling 8,500 Btu/h – 22,200 Btu/h 2.5 kW – 6.5 kWHeating 9,600 Btu/h – 25,200 Btu/h 2.8 kW – 7.4 kW
McQuay is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoGuard combines powerful sterilizing and deodorizing effect of NanoSilver and Nano-Photocatalyst.
Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into anti-bacterial applications ever since. Modern nanotechnology provides through full-infusion onto the filters and larger coated surface area.
16 17
New Aesthetically OutlookA smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design. The centrally located LED light makes it easier for user to check the operating conditions.
3-Fold Heat Exchanger
The compact design of this 3-foldstructure provides a large surfacearea for better & efficientheat exchange.
Double LouverThis new louver design together with its automatic air swing function fully optimizes the room comfort by distributing the air evenly to every corner of the room.
NanoPhotocatalyst -deVOCs & deodorization(150 times stronger than highperformance activated carbon)
Pre Filter
NanoSilver-bacteria &germs elimination
CKCeiling CassetteA Series & C SeriesMCKD 010/015/020 CMCKD 020/025/030/040/050 AM5CKD 010/015/020 CM5CKD 020/025/030/040/050 ACooling 9,600 Btu/h – 47,800 Btu/h 2.8 kW – 14.0 kWHeating 10,900 Btu/h – 54,600 Btu/h 3.2 kW – 16.0 kW
STYLISH AND SLIM PANELThe slim panel can be blended easily into most interior decoration and design.
700mm
CEILING AND FLOOR INSTALLATION OPTIONThe MCMD is designed with the option to install either below the ceiling or mounted at low wall position to suit most interior design requirement.
4 WAY AIR DISCHARGE AND AIR SWINGIt comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.
CCCeiling ConvertibleE SeriesMCMD 020/025/028 EM5CMD 015/020/025/028 ECooling 19,100 Btu/h - 27,300 Btu/h 5.6 kW - 8.0 kWHeating 21,500 Btu/h - 30,700 Btu/h 6.3 kW - 9.0 kW
700mm
BUILT-IN HIGH HEAD DRAIN PUMPThe unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.
FLEXIBLE INSTALLATION The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.
18 19
BETTER SERVICEABILITYThe washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access. • Fan Motor• Blower• Wiring Connection• Control Box• Piping Connection
Wall bracket supplied as optional item
Primary Drain PanPolysterene (Ps) With Height Impact Polystyrene (Hips) Cover
Secondary Drain Pan With Insulation
Discharge Adaptor
Square GrilleAssembly c/w Adaptor
Secondary Drain Pan with Insulation
Primary Drain Pan
Square Return Grille Assembly
c/w Adaptor & Filter
FlexibleRound Duct(field supply)
Ceiling Concealed UnitACC Return AssemblyBracket c/w Adaptor
FlexibleRound Duct
(field supply)
Available for MCCD 010-025 C/CR only.
CMCeiling ConvertibleD SeriesMCMD 040/050 DMCMD 062 CM5CMD 040/050 DM5CMD 062 CCooling 38,200 Btu/h – 56,000 Btu/h 11.2 kW – 16.4 kWHeating 42,700 Btu/h – 63,100 Btu/h 12.5 kW – 18.5 kW
Ceiling ConcealedC SeriesMCCD 010/015/020/025/030/040/050/060 CM5CCD 010/015/020/025/028/030/038/040/050/060 CCooling 9,600 Btu/h – 56,000 Btu/h 2.8 kW – 16.4 kWHeating 10,900 Btu/h – 63,100 Btu/h 3.2 kW – 18.5 kW
CC
TWO WAY AIR DISCHARGE
Equipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.
AUTOMATIC AIR SWING
The swing mode enables the air flow to be evenly distributed into the room from the front discharge area.
CEILING AND FLOOR INSTALLING OPTION
The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit most interior design requirements.
DOUBLE PROTECTION DRAINAGE SYSTEM
The primary drain pan is designed with higher thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.
FLEXIBILITY IN SYSTEM DESIGN
The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system.
DUCT ACCESSORIES (OPTIONAL)
A set duct accessories specifically designed to fit and to suit the MCCD-C model is being created. Thus offers a one stop solution to installing the unit.
20 21
ICE CREAM
ICE CREAM
COMPLETE MODELTo ease installation, this model has the Electronic Expansion Valve (EXV) built into the unit. User do not need to worry about the noise from the EXV as it is properly insulated.
DBDucted BlowerMDBD 080 / 100Cooling 76,400 Btu/h – 95,500 Btu/h 22.4 kW – 28.0 kWHeating 85,300 Btu/h – 107,500 Btu/h 25.0 kW – 31.5 kW
MDS SYSTEM MANAGEMENT SOFTWAREFor central monitoring and control purposes, the MDS offers a real time system. This software is the system to human interface, allowing users or owners to monitor and to control the MDS system. With this software, user or owners is able to ;• Monitor & control any MDS indoor & outdoor unit • Alarming alert• Zoning & grouping capabilities • Scheduling option
BETTER AIR DISTRIBUTION FOR COMFORTABLE LIVINGThe conditioned air can be effectively distributed to the room through ducting.
EXTENDED INDOOR MODELThe ducted blower is designed to cater higher indoor capacity required. Combining ceiling concealed and ducted blower, the MDS system is able to fulfill ducted application with capacity range from 2.8kW to 28.0kW
As a system provider, McQuay MDS system is equipped together with a collection of customized software to provide system design & selection and individual units control & monitoring.
22 23
DESIGN SOFTWAREThis software is incorporated with data on indoor models. This allow the designers to choose the appropriate indoors model to suit they needs. Besides that, this software will determine the required quantity of refnet joints, pipes and other accessories base on the design. With this software, most designs can be completed with just a few simple clicks.
CENTRAL CONTROLLEROptional Item. To provide group or individual control to indoors (Up to 32 indoors). Basic control such as ON/OFF, mode setting, temperature setting and others.
AC 5300Optional Item. To provide wireless control for wired controller. Basic control such as ON/OFF, mode setting, temperature setting and others.
Standard Controller
Optional Controllerand Accessories
REFNET & DISTRIBUTORS JOINTPiping joint design for the MDS system. A total of 6 types of refnet joint is available for different piping combination.
PC CONTROLMDS Central Monitoring Software (known as Smart Commander) act as the system to human interface. A communication gateway is inclusive for the wiring connection.
WIRED CONTROLLERStandard wired controller for MCCD-C. Basic control such as ON/OFF, mode setting, tempera-ture setting and others.
WIRELESS G17Standard wireless handset for wall mounted, ceiling cassette and ceiling convertible. Basic control such as ON/OFF, mode setting, temperature setting and others.
Commercial SectorCountry : ThailandIndoor Type : Ceiling Concealed
Commercial SectorCountry : ChinaIndoor Type : Ceiling Concealed Ceiling Convertible
Residential SectorCountry : QatarIndoor Type : Wall Mounted
Residential SectorCountry : IndonesiaIndoor Type : Ceiling Concealed
Commercial SectorCountry : SingaporeIndoor Type : Ceiling Concealed Ceiling Convertible Ceiling Cassette
Residential SectorCountry : SyriaIndoor Type : Ceiling Concealed
MDS systems has proven to be reliable and a system of choice.Many projects, whether government or privately own premises had chosen MDS as their comfort provider:
24 25
R-221
R-222
R-22 Outdoor Specifications
COOLING
HEATING
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
NOMINAL COOLING CAPACITY
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
UNIT DIMENSION
POWER SOURCE - 1Ø <3Ø>
REFRIGERANT TYPE
SOUND PRESSURE LEVEL
AIR FLOW
MODEL OUTDOOR UNIT
OU
TD
OO
R U
NIT
MDS 070AR
61,400
18,000
68,200
20,000
6,200
6,000
MDS 070A
61,400
18,000
6,200
380-415/3/50
R-22
2225/4694
62
1445/56.9
1058/41.6
430/16.9
140/309
Flare
9.52 / 3/8
19.05 / 3/4
MDS 060AR
49,474
14,500
56,298
16,500
5,000 <5,000>
4,200 <4,200>
MDS 060A
49,474
14,500
5,000 <5,000>
220-240/1/50 <380-415/3/50>
R-22
1055+1055/2230+2230
60
1247/49.1
1058/41.7
430/16.9
130/287
Flare
9.52 / 3/8
19.05 / 3/4
MDS 050AR
42,650
12,500
46,062
13,500
4,400 <4,300>
4,200 <3,900>
MDS 050A
42,650
12,500
4,400 <4,300>
220-240/1/50 <380-415/3/50>
R-22
695+695/1470+1470
59
1044/41.1
1058/41.7
430/16.9
120/265
Flare
9.52 / 3/8
19.05 / 3/4
MDS 040AR
34,120
10,000
39,238
11,500
3,500
3,400
MDS 040A
34,120
10,000
3,500
220-240/1/50
R-22
695+695/1470+1470
59
1044/41.1
1058/41.7
430/16.9
115/254
Flare
9.52 / 3/8
19.05 / 3/4
MDS 030AR
29,002
8,500
30,708
9,000
3,000
2,500
MDS 030A
29,002
8,500
3,000
220-240/1/50
R-22
1055/2230
59
900/35.4
840/33.0
408/16.0
85/188
Flare
9.52 / 3/8
15.88 / 5/8
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
MDS-AR
HI-FAN
LOW-FAN
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT WEIGHT
PIPE CONNECTION
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
MODEL OUTDOOR UNIT
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
SIZE
UNIT DIMENSION
POWER SOURCE
REFRIGERANT TYPE
TYPE (LIQUID/GAS)
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
MDS 120BR MDS 150BR
110,890 136,480
32,500 40,000
116,008 146,716
34,000 43,000
9,800 12,900
9,000 11,100
MDS 120B MDS 150B
110,890 136,480
32,500 40,000
9,800 12,900
380-415/3/50
R-22 R-22
3472/7357 3750/7945
2083/4414 2222/4708
66 67
1840/72.4 1840/72.4
990/39.0 1290/50.8
840/33.0 840/33.0
290/639 355/783
Flare/Brazed Flare/Brazed
15.88/0.625 15.88/0.625
28.6/1.125 34.9/1.375
MDS 100BR
95,536
28,000
102,360
30,000
8,500
8,300
MDS 100B
95,536
28,000
8,500
R-22
3194/6768
1528/3237
64
1840/72.4
990/39.0
840/33.0
385/628
Flare/Brazed
12.7/0.5
28.6/1.125
MDS 080BR
83,594
24,500
88,712
26,000
7,500
7,200
MDS 080B
83,594
24,500
7,500
R-22
3194/6768
1528/3237
62
1840/72.4
990/39.0
840/33.0
275/606
Flare/Brazed
12.7/0.5
28.6/1.125
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
MDS-BR
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
HI-FAN
LOW-FAN
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE (LIQUID/GAS)
SIZE
NOMINAL COOLING CAP ACITY
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
MASTER UNIT+SLAVE UNIT
OUTDOOR UNITMODEL
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
MDS 260BR MDS 280BR MDS 300BR MDS 320B
MDS 120BRM+MDS 150BRS MDS 150BRM+MDS 130BRS MDS 150BRM+MDS 150BRS MDS 160BRM+MDS 160BRS
238,840 255,900 272,960 290,020
70,000 75,000 80,000 85,000
255,900 272,960 290,020 313,904
75,000 80,000 85,000 92,000
21,300 22,800 26,200 27,700
20,900 22,000 23,600 25,500
MDS 260B MDS 280B MDS 300B MDS 320B
MDS 120BM+MDS 150BS MDS 150BM+MDS 130BS MDS 150BM+MDS 150BS MDS 160BM+MDS160BS
238,840 255,900 272,960 290,020
70,000 75,000 80,000 85,000
21,300 22,800 26,200 27,700
380-415/3/50
R-22 R-22 R-22 R-22
3472+3750/7357+7945 3750+3750/7945+7945 3750+3750/7945+7945 3750+3750/7945+7945
2083+2222/4414+4708 2222+2222/4708+4708 2222+2222/4708+4708 2222+2222/4708+4708
68 69 69 69
1840/72.4 1840/72.4 1840/72.4 1840/72.4
2290/90.2 2590/102.0 2590/102.0 2590/102.0
840/33.0 840/33.0 840/33.0 840/33.0
645/1422 710/1565 710/1565 720/1587
Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed
19.05/0.75 19.05/0.75 19.05/0.75 19.05/0.75
41.3/1.625 41.3/1.625 41.3/1.625 41.3/1.625
MDS-BR
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
MDS-BR
HI-FAN
LOW-FAN
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE (LIQUID/GAS)
SIZE
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
MODEL OUTDOOR UNIT MDS 180BR MDS 200BR MDS 220BR MDS 240BR
162,070 170,600 187,660 221,780
47,500 50,000 55,000 65,000
170,600 180,836 197,896 232,016
50,000 53,000 58,000 68,000
14,100 15,200 16,700 19,800
13,200 14,700 16,200 18,500
MDS 180B MDS 200B MDS 220B MDS 240B
162,070 170,600 187,660 221,780
47,500 50,000 55,000 65,000
14,100 15,200 16,700 19,800
380-415/3/50
R-22 R-22 R-22 R-22
3194+3194/6768+6768 3194+3194/6768+6768 3194+3194/6768+6768 3472+3472/7357+7357
1528+1528/3237+3237 1528+1528/3237+3237 1528+1528/3237+3237 2083+2083/4414+4414
66 66 66 68
1840/72.4 1840/72.4 1840/72.4 1840/72.4
1990/78.3 1990/78.3 1990/78.3 1990/78.3
840/33.0 840/33.0 840/33.0 840/33.0
520/1 146 560/1235 560/1235 570/1257
Flare/Brazed Flare/Brazed Flare/Brazed Flare/Brazed
15.88/0.625 15.88/0.625 19.05/0.75 19.05/0.75
34.9/1.375 34.9/1.375 38.1/1.5 38.1/1.5
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
R-223
R-224
R-22 Indoor SpecificationsMWMD-G
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
IND
OO
R U
NIT
UNIT WEIGHT
CONTROLAIR DISCHARGE
OPERATION
AIR FLOW
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
CONDENSATE DRAIN SIZE
POWER SOURCE
REFRIGERANT TYPE/ CONTROL
PIPE CONNECTION
TYPE
SIZE
MWMD 009G MWMD 010G MWMD 015G MWMD 020G MWMD 025G
8500 9600 12300 19100 22200
2.5 2.8 3.6 5.6 6.5
9600 10900 13600 21500 25200
2.8 3.2 4.0 6.3 7.4
130 / 275 142 / 300 163 / 345 231 / 490 397 / 630
106 / 225 118 / 250 135 / 285 193 / 410 231 / 490
83 / 175 94 / 200 104 / 220 160 / 340 208 / 440
40 / 35 / 29 39 / 34 / 28 42 / 36 / 29 43 / 40 / 35 49 / 44 / 42
304 / 12.0 304 / 12.0
799 / 31.5 1062 / 41.8 1062 / 41.8
222 / 8.7 222 / 8.7
10/22.05 16 / 35.27 16 / 35.27
9.52 / 3/8
12.70 / 1/2
20 / 0.79
899 / 35.4
12/26.46
220 - 240 / 1 / 50
R-22 / EXV
DOUBLE LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
WIRELESS REMOTE CONTROL
260 / 10.2
198 / 7.8
16 / 0.63
FLARE VALVE
6.35 / 1/4
9.52 / 3/8 15.88 / 5/8
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / cfm
l/s / cfm
l/s / cfm
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
MCKD-C
EXTERNAL STATIC PRESSURE (H/M/L)
PIPE CONNECTIONSIZE
AIR FLOW
REFRIGERANT TYPE / CONTROL
CONTROLAIR DISCHARGE
OPERATION
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT (UNIT + PANEL)
CONDENSATE DRAIN SIZE
UNIT DIMENSION
( ) - WITH PANEL
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
IND
OO
R U
NIT
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MCKD 020C
19100
5.6
21500
6.3
220 - 240 / 1 / 50
R-22 / EXV
212 / 450
203 / 430
194 / 410
0
47 / 46 / 44
23 + 2 / 50.7 + 4.4
15.88 / 5/8
MCKD 015C
12300
3.6
13600
4.0
194 / 410
184 / 390
170 / 360
0
44 / 42 / 41
23.2 / 50.7 + 4.4
12.70 / 1/2
FLARE VALVE
6.35 / 1/4
19.05 / 3/4
4 WAY AUTOMATIC LOUVER (UP & DOWN)
WIRELESS REMOTE CONTROL
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
250 (295) / 9.8 (11.6
R-22 / EXV
220 - 240 / 1 / 50
MCKD 010C
9600
2.8
10900
3.2
194 / 410
184 / 390
175 / 370
0
44 / 43 / 42
22 + 2 / 48.5 + 4.4
9.52 / 3/8
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
Pa / in.wg.
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
TYPE
MCMD-E
NOTE:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
EXTERNAL STATIC PRESSURE (H/M/L)
CONDENSATE DRAIN SIZE
POWER SOURCE
REFRIGERANT TYPE / CONTROL
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
UNIT WEIGHT
CONTROLAIR DISCHARGE
OPERATION
UNIT DIMENSION
PIPE CONNECTION 9.52 / 3/8
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
IND
OO
R U
NIT
0
MCMD 028E
27300
8.0
30700
9.0
293 / 620
269 / 570
245 / 520
51 / 48 / 47
28 / 62
MCMD 025E
22200
6.5
25200
7.4
274 / 580
250 / 530
231 / 490
0
50 / 47 / 46
220 - 240 / 1 / 50
R-22 / EXV
AUTOMATIC LOUVER (UP & DOWN)
WIRELESS REMOTE CONTROL
FLARE VALVE
15.88 / 5/8
218 / 8.58
1080 / 42.52
630 / 24.80
19.05 / 3/4
27 / 60
MCMD 020E
19100
5.6
21500
6.3
245 / 520
217 / 460
192 / 406
0
48 / 46 / 43
6.35 / 1/4
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
Pa / in.wg.
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
TYPE
SIZELIQUID
GAS
MCKD-A
EXTERNAL STATIC PRESSURE (H/M/L)
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
PIPE CONNECTION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
AIR DISCHARGECONTROL
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
CONDENSATE DRAIN SIZE
UNIT DIMENSION
( ) - WITH PANEL
UNIT WEIGHT (UNIT + PANEL)
MODEL INDOOR UNIT
POWER SOURCE
REFRIGERANT TYPE / CONTROL
INDOOR UNIT
IND
OO
R U
NIT
MCKD 020A MCKD 025A MCKD 030A MCKD 040A MCKD 050A
19100 22200 30700 38200 47800
5.6 6.5 9.0 11.2 14.0
21500 25200 34100 42700 54600
6.3 7.4 10.0 12.5 16.0
220 - 240 / 1 / 50
R-22 / EXV
349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040
297 / 630 311 / 660 349 / 740 406 / 860 448 / 950
283 / 600 283 / 600 321 / 680 359 / 760 411 / 870
0 0 0
42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50
31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8
6.35 / 1/4
19.05 / 3/4
FLARE VALVE
9.52 / 3/8
15.88 / 5/8 19.05 / 3/4
820 (930) / 32.2 (36.6)
0
220 - 240 / 1 / 50
R-22 / EXV
4 WAY AUTOMATIC LOUVER (UP & DOWN)
WIRELESS REMOTE CONTROL
335 (378) / 13.2 (14.9)
820 (930) / 32.2 (36.6)
220 - 240 / 1 / 50
R-22 / EXV
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
Pa / in.wg.
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
OPERATION
TYPE
SIZE
HEIGHT
WIDTH
HIGH
DEPTH
MEDIUM
LOW
LIQUID
GAS
R-225
R-226
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB/D17758 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4M BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM).
MDBD
Btu/h
W
Btu/h
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
LIQUID mm/inGAS mm/in
MDBD 080
76400
22400
85300
1700
1444 / 3058
1250 / 2647
1083 / 2294
100 / 0.40
420 / 16.5
25.4 / 1.0
28.6 / 1 1/8
MODEL
AIR FLOW
DEPTH
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT CONTROL (EXPANSION DEVICE)
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
CONDENSATE DRAIN SIZE
1690 / 66.5
879 / 34.6
100 / 220
PIPE CONNECTIONTYPE
SIZE12.7 / 1/2 12.7 / 1/2
WNOMINAL TOTAL INPUT POWER
REFRIGERANT TYPE
IND
OO
R U
NIT
MDBD 100
95500
28000
107500
1480
25000 31500
1750 / 3706
-
-
150 / 0.60
520 / 20.5
1580 / 62.2
57 57
1020 / 40.2
150 / 330
25.4 / 1.0
28.6 / 1 1/8
220 ~ 240 / 1 / 50 380 ~ 415 / 3 / 50
EXV
WIRED CONTROL
DUCTED
FLARE VALVE
R-22
EXTERNAL STATIC PRESSURE (H/M/L)
LIQUID
GAS
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE / CONTROL
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
MODEL
AIR FLOW
SUPER HIGH
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
PIPE CONNECTION
TYPE
SIZE
CONDENSATE DRAIN SIZE
DEPTH
MCCD-C
IND
OO
R U
NIT
MCCD 060C
56000
16.4
63100
18.5
779 / 1650
722 / 1530
675 / 1430
609 / 1290
176/157/137/98(0.71/0.63/0.55/0.39)
55 / 53 / 50 / 47
378 / 14.88
1499 / 59.02
541 / 21.30
62 / 136.69
12.70 / 1/2
MCCD 050C
47800
14.0
54600
16.0
750 / 1590
651 / 1380
604 / 1280
571 / 1210
176/157/137/108(0.71/0.63/0.55/0.43)
53 / 52 / 50 / 47
378 / 14.88
1299 / 51.14
541 / 21.30
54 / 119.05
19.05 / 3/4
FLARE VALVE
R-22 / EXV
DUCTED
WIRED CONTROL
19.05 / 3/4
220 - 240 / 1 / 50
MCCD 040C
38200
11.2
42700
12.5
519 / 1100
500 / 1060
467 / 990
425 / 900
206/176/127/93(0.83/0.71/0.51/0.37)
51 / 49 / 45 / 41
378 / 14.88
1045 / 41.14
541 / 21.30
42 / 92.59
9.52 / 3/8
MCCD 030C
30700
9.0
34100
10.0
425 / 900
392 / 830
359 / 760
335 / 710
206/167/127/88(0.83/0.67/0.51/0.35)
49 / 46 / 42 / 38
378 / 14.88
929 / 36.57
541 / 21.30
39 / 85.98
15.88 / 5/8
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
Pa (in.wg.)
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
LIQUID
GAS
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
UNIT DIMENSION
HEIGHT
AIR DISCHARGE
HIGH
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
LOW
MEDIUM
IND
OO
R U
NIT
OPERATION
POWER SOURCE
REFRIGERANT TYPE / CONTROL
CONTROL
PIPE CONNECTION
TYPE
SIZE
MCMD-D/C
MCMD 040D MCMD 050D MCMD 062C
Btu/h 38200 47800 56000
kW 11.2 14.0 16.4
Btu/h 42700 54600 63100
kW 12.5 16.0 18.5
V/Ph/Hz
l/s / CFM 477 / 1010 491 / 1040 731 / 1550
l/s / CFM 420 / 890 448 / 950 623 / 1320
l/s / CFM 368 / 780 387 / 820 472 / 1000
dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46
mm/in 285 / 11.2
mm/in 1903 / 74.9
mm/in 680 / 26.8
kg/lb 85 / 187.4
mm/in
mm/in 12.7 / 1/2
mm/in
70 / 154.3
1714 / 67.40
670 / 26.30
249 / 9.80
AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)
WIRELESS REMOTE CONTROL
220 - 240 / 1 / 50
R-22 / EXV
19.05 / 3/4
9.52 / 3/8
FLARE VALVE
19.05 / 3/4
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
MCCD-C
EXTERNAL STATIC PRESSURE (H/M/L)
LIQUID
GAS
MODEL
AIR FLOW
SUPER HIGH
DEPTH
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE / CONTROL
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
CONDENSATE DRAIN SIZE
PIPE CONNECTION
TYPE
SIZE15.88 / 5/8
IND
OO
R U
NIT
MCCD 025C
22200
6.5
25200
7.4
-
382 / 810
359 / 760
288 / 610
41/31/18(0.16/0.12/0.07)
40 / 39 / 36
261 / 10.28
1200 / 47.24
411 / 16.18
25 / 55.1
9.52 / 3/8
MCCD 020C
19100
5.6
21500
6.3
-
316 / 670
302 / 640
278 / 590
69/65/42(0.28/0.26/0.17)
38 / 36 / 34
261 / 10.28
1065 / 41.93
411 / 16.18
22 / 48.5
220 - 240 / 1 / 50
R-22 / EXV
DUCTED
WIRED CONTROL
19.05 / 3/4
FLARE VALVE
MCCD 015C
12300
3.6
13600
4.0
-
241 / 510
208 / 440
170 / 360
49/39/20(0.20/0.16/0.08)
37 / 34 / 29
21 / 46.3
12.70 / 1/2
261 / 10.28
905 / 35.63
411 / 16.18
6.35 / 1/4
MCCD 010C
9600
2.8
10900
3.2
-
142 / 300
123 / 260
104 / 220
49/39/29(0.20/0.16/0.12)
33 / 30 / 26
17 / 37.5
9.52 / 3/8
261 / 10.28
765 / 30.12
411 / 16.18
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
Pa (in.wg.)
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
mm/in
R-410A1
R-410A2
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
COOLING
HEATING
HEIGHT
WIDTH
DEPTH
LIQUID
GASSIZE
NOMINAL TOTAL INPUT POWER
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE (LIQUID/GAS)
NOMINAL TOTAL INPUT POWER
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
MODEL OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
5MDS 070BR
64,800
19,000
71,600
21,000
6,000
5,900
5MDS 070B
64,800
19,000
6,000
380-4150/ 3/ 50
R-22
1775 / 3765
62
1349 / 53.1
1058 / 41.6
430 / 16.9
135 / 297
FLARE / BRAZE
9.52 / 3/8
15.88 / 5/8
5MDS 060BR
51,100
15,000
59,700
17,500
4,700
4,400
5MDS 060B
51,100
15,000
4,700
380-415 / 3 / 50
R-22
1665 / 3530
60
1247 / 49.1
1058 / 41.7
430 / 16.9
130 / 287
FLARE / BRAZE
9.52 / 3/8
15.88 / 5/8
5MDS 050BR
46,000
13,500
51,100
15,000
4,400
4,300
5MDS 050B
46,000
13,500
4,400
380-415 / 3 / 50
R-22
1220 / 2590
59
1044 / 41.4
1058 / 41.7
430 / 16.9
120 / 265
FLARE / BRAZE
9.52 / 3/8
15.88 / 5/8
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
R-410A Outdoor Specification5MDS-BR
5MDS 080BR 5MDS 100BR 5MDS 120BR 5MDS 140BR 5MDS 160BR
Btu/h 85,300 95,536 112,596 129,656 143,304
W 25,000 28,000 33,000 38,000 42,000
Btu/h 95,536 109,184 126,244 143,304 160,364
W 28,000 32,000 37,000 42,000 47,000
COOLING W 7,200 8,000 9,700 11,300 12,900
HEATING W 7,000 7,900 9,400 10,900 11,900
5MDS 080B 5MDS 100B 5MDS 120B 5MDS 140B 5MDS 160B
Btu/h 85,300 95,536 112,596 129,656 143,304
W 25,000 28,000 33,000 38,000 42,000
W 7,200 8,000 9,700 11,300 12,900
V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50 380 - 415 / 3 / 50
R-410A R-410A R-410A R-410A R-410A
HI-FAN l/s / cfm 3056 / 6474 3056 / 6474 3055 / 6474 3333 / 7063 3333 / 7063
LOW-FAN l/s / cfm 1528 / 3237 1528 / 3237 1528 / 3237 2083 / 4414 2083 / 4414
dB(A) 56 57 60 60 60
HEIGHT mm/in 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4 1840 / 72.4
WIDTH mm/in 990 / 39.0 990 / 39.0 990 / 39.0 1290 / 50.8 1290 / 50.8
DEPTH mm/in 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0 840 / 33.0
kg/lb 290 / 639 300 / 661 305 / 672 350 / 771 360 / 793
Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed Flare / Brazed
LIQUID mm/in 9.52 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2 12.7 / 1/2
GAS mm/in 22.2 / 7/8 22.2 / 7/8 22.2 / 7/8 28.6 / 11/8 28.6 / 11/8
kg/lb 7.9 / 17.4 10.0 / 22.0 10.6 / 23.4 12.2 / 26.9 13.4 / 29.5
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
MODEL OUTDOOR UNIT
TYPE (LIQUID/GAS)
SIZE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
MODEL
5MDS-BR
5MDS 260BR
5MDS 120BRM + 5MDS 140BRS
242,252
71,000
266,136
78,000
COOLING 21,000
HEATING 20,300
5MDS 260B
242,252
71,000
21,000
380 - 415 / 3 / 50
R-410A
HI-FAN 3056 + 3333 / 6474 + 7063
LOW-FAN 1528 + 2083 / 3237 + 4414
62
HEIGHT 1840 / 72.4
WIDTH 2290 / 90.2
DEPTH 840 / 33.0
655 / 1444
Flare / Brazed
LIQUID 15.9 / 5/8GAS 34.9 / 13/4
22.8 / 50.3
OUTDOOR UNIT
MODELMASTER UNIT+SLAVE UNIT
MODELMASTER UNIT+SLAVE UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUTPOWER
UNIT DIMENSION
POWER SOURCE
REFRIGERANT TYPE
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
OU
TD
OO
R U
NIT
UNIT WEIGHT
PIPECONNECTION
TYPE (LIQUID/GAS)
SIZE
REFRIGERANT CHARGE
AIR FLOW
SOUND PRESSURE LEVEL
5MDS 180BR
-
160,364
47,000
180,836
53,000
14,500
13,800
5MDS 180B
-
160,364
47,000
14,500
380 - 415 / 3 / 50
R-410A
3472 / 7357
2222 / 4708
61
1840 / 72.4
1290 / 50.8
840 / 33.0
370 / 816
Flare / Brazed
12.7 / 1/2
28.6 / 11/814.8 / 32.6
5MDS 200BR
-
180,836
53,000
201,308
59,000
16,200
14,700
5MDS 200B
-
180,836
53,000
16,200
380 - 415 / 3 / 50
R-410A
61
1840 / 72.4
1990 / 78.3
840 / 33.0
590 / 1301
Flare / Brazed
15.9 / 5/8
28.6 / 11/818.0 / 39.7
5MDS 220BR
-
197,896
58,000
221,780
65,000
17,700
16,900
5MDS 220B
-
197,896
58,000
17,700
380 - 415 / 3 / 50
R-410A
62
1840 / 72.4
1990 / 78.3
840 / 33.0
590 / 1301
Flare / Brazed
15.9 / 5/8
28.6 / 11/819.6 / 43.2
5MDS 240BR
-
218,368
64,000
242,252
71,000
19,800
18,500
5MDS 240B
- -
218,368
64,000
19,800
380 - 415 / 3 / 50
R-410A
62
1840 / 72.4
1990 / 78.3
840 / 33.0
600 / 1323
Flare / Brazed
15.9 / 5/8
28.6 / 11/821.5 / 47.4
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
kg/lb
3056 x 2 / 6474 x 2 3056 x 2 / 6474 x 22778 x 2 / 5886 x 2
1528 x 2 / 3237 x 2 1528 x 2 / 3237 x 2 1528 x 2 / 3237 x 2
5MDS-BR
5MDS 360BR
5MDS 180BRM + 5MDS 180BRS
Btu/h 320,728
W 94,000
Btu/h 361,672
W 106,000
COOLING W 29,000
HEATING W 27,600
5MDS 360B
5MDS 180BM + 5MDS 180BS
Btu/h 320,728
W 94,000
W 29,000
V/Ph/Hz 380 - 415 / 3 / 50
R-410A
HI-FAN l/s / cfm
LOW-FAN l/s / cfm
dB(A) 63
HEIGHT mm/in 1840 / 72.4
WIDTH mm/in 2590 / 102.0
DEPTH mm/in 840 / 33.0
kg/lb 740 / 1631
Flare / Brazed
LIQUID mm/in 19.1 / 3/4GAS mm/in 34.9 / 13/4
kg/lb 34.0 / 75.0
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
TYPE (LIQUID/GAS)
SIZE
UNIT DIMENSION
UNIT WEIGHT
PIPECONNECTION
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUTPOWER
NOMINAL TOTAL INPUT POWER
MODELOUTDOOR UNIT
5MDS 340BR
5MDS 180BRM + 5MDS 160BRS
303,668
89,000
341,200
100,000
27,400
25,700
5MDS 340B
5MDS 180BM + 5MDS 160BS
303,668
89,000
27,400
380 - 415 / 3 / 50
R-410A
3472 + 3333 / 7357 + 7063
2222 + 2083 / 4708 + 4414
3472 x 2 / 3753 x 2
2222 x 2 / 4708 x 2
63
1840 / 72.4
2590 / 102.0
840 / 33.0
730 / 1609
Flare / Brazed
19.1 / 3/4
34.9 / 13/434.0 / 75.0
5MDS 320BR
5MDS 180BRM + 5MDS 140BRS
290,020
85,000
324,140
95,000
25,800
24,700
5MDS 320B
5MDS 180BM + 5MDS 140BS
290,020
85,000
25,800
380 - 415 / 3 / 50
R-410A
3472 + 3333 / 7357 + 7063
2222 + 2083 / 4708 + 4414
63
1840 / 72.4
2590 / 102.0
840 / 33.0
720 / 1587
Flare / Brazed
15.9 / 3/4
34.9 / 13/432.0 / 92.6
5MDS 300BR
5MDS 120BRM + 5MDS 180BRS
272,960
80,000
296,844
87,000
24,200
23,200
5MDS 300B
5MDS 120BM + 5MDS 180BS
272,960
80,000
24,200
380 - 415 / 3 / 50
R-410A
3056 + 3472 / 6474 + 7357
1528 + 2222 / 3237 + 4708
62
1840 / 72.4
2290 / 90.2
840 / 33.0
675 / 1488
Flare / Brazed
15.9 / 5/8
34.9 / 13/430.0 / 66.1
5MDS 280BR
5MDS 120BRM + 5MDS 160BRS
255,900
75,000
279,784
82,000
22,600
21,300
5MDS 280B
5MDS 120BM + 5MDS 160BS
255,900
75,000
22,600
380 - 415 / 3 / 50
R-410A
3056 + 3333 / 6474 + 7063
1528 + 2083 / 3237 + 4414
62
1840 / 72.4
2290 / 90.2
840 / 33.0
665 / 1466
Flare / Brazed
15.9 / 5/8
34.9 / 13/424.0 / 52.9
5MDS-BR
R410A3
R410A4
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
IND
OO
R U
NIT
M5WMD-G
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
INDOOR MODEL
NOMINAL TOTAL INPUT POWER
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
SIZE
POWER SOURCE
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT
UNIT DIMENSION
AIR FLOW
PIPE CONNECTION
TYPE
M5WMD 009G M5WMD 010G M5WMD 015G
Btu/h 8500 9600 12300
W 2500 2800 3600
Btu/h 9600 10900 13600
W 2800 3200 4000
24 26 29W
V/Ph/Hz
l/s / cfm 130 / 275 142 / 300 163 / 345
l/s / cfm 106 / 225 118 / 250 135 / 285
l/s / cfm 83 / 175 94 / 200 104 / 220
dBA 40 / 35 / 29 39 / 34 / 28 42 / 36 / 29
mm/in
mm/in 799 / 31.5
mm/in
kg/lb 10/22.05
mm/in
mm/in 12.7 / 1/2
220-240/1/50
FLARE VALVE
9.5 / 3/8
12/26.46
899 / 35.4
6.4 / 1/4
260 / 10.2
198 / 7.8
IND
OO
R U
NIT
M5WMD-G
HIGH
MEDIUM
LOW
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
INDOOR MODEL
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
POWER SOURCE
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
M5WMD 025G
Btu/h 22200
W 6500
Btu/h 25200
W 7400
66W
V/Ph/Hz
l/s / cfm 397 / 630
l/s / cfm 231 / 490
l/s / cfm 208 / 440
dBA 49 / 44 / 42
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
16 / 35.27
FLARE VALVE
6.4 / 1/4
15.9 / 5/8
220-240/1/50
304 / 12.0
1062 / 41.8
222 / 8.7
M5WMD 020G
19100
5600
21500
6300
47
231 / 490
193 / 410
160 / 340
43 / 40 / 35
12.7 / 1/2
R410A Indoor Specifications
NOTE :1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT THE MACHINE AND 1.42m ABOVE THE MACHINE BASE.5) THE VALUE OF REFRIGERANT CHARGE IS THE REFRIGERANT CHARGED IN THE OUTDOOR UNIT BEFORE LEAVING FACTORY. THIS CHARGE DOES NOT INCLUDE THE AMOUNT NEEDED FOR EXTENDED PIPING.
COOLING
HEATING
HI-FAN
LOW-FAN
HEIGHT
WIDTH
DEPTH
LIQUID
GAS
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
TYPE (LIQUID/GAS)
SIZE
UNIT DIMENSION
UNIT WEIGHT
PIPECONNECTION
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTALINPUT POWER
NOMINAL TOTAL INPUT POWER
MODELOUTDOOR UNIT
5MDS 440BR
5MDS 240BRM + 5MDS 200BRS
399,204
117,000
443,560
130,000
36,000
33,200
5MDS 440B
5MDS 240BM + 5MDS 200BS
399,204
117,000
36,000
380 - 415 / 3 / 50
R410a
65
3056 x 4 / 6474 x 4
1528 x 4 / 3237 x 4
1840 / 72.4
3990 / 129.5
840 / 33.01190 / 2624
Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
44.0 / 97.0
5MDS 420BR
5MDS 240BRM + 5MDS 180BRS
378,732
111,000
423,088
124,000
34,300
32,300
5MDS 420B
5MDS 240BM + 5MDS 180BS
378,732
111,000
34,300
380 - 415 / 3 / 50
R410a
65
3056 x 2 + 3472 / 6474 x 2 + 7357
1528 x 2 + 2083 / 3237 x 2 + 4708
1840 / 72.4
3290 / 129.5
840 / 33.0970 / 2138
Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
42.0 / 92.6
5MDS 400BR
5MDS 240BRM + 5MDS 160BRS
361,672
106,000
402,616
118,000
32,700
30,400
5MDS 400B
5MDS 240BM + 5MDS 160BS
361,672
106,000
32,700
380 - 415 / 3 / 50
R410a
65
3056 x 2 + 3333 / 6474 x 2 + 7063
1528 x 2 + 2083 / 3237 x 2 + 4414
1840 / 72.4
3290 / 129.5
840 / 33.0960 / 2116
Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
40.0 / 88.2
5MDS 380BR
5MDS 240BRM + 5MDS 140BRS
348,024
102,000
385,556
113,000
31,100
29,400
5MDS 380B
5MDS 240BM + 5MDS 140BS
348,024
102,000
31,100
380 - 415 / 3 / 50
R410a
64
1840 / 72.4
3056 x 2 + 3333 / 6474 x 2 + 7063
1528 x 2 + 2083 / 3237 x 2 + 4414
3290 / 129.5
840 / 33.0950 / 2094
Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
38.0 / 83.4
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/in
mm/inkg/lb
mm/in
mm/in
kg/lb
5MDS-BR
COOLING
HEATING
HI-FAN
LOW-FAN
HEIGHT
WIDTHDEPTH
LIQUIDGAS
NOMINAL COOLING CAPACITY
MODELOUTDOOR UNIT
MASTER UNIT+SLAVE UNIT
REFRIGERANT CHARGE
REFRIGERANT TYPE
OU
TD
OO
R U
NIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT WEIGHT
PIPECONNECTION
TYPE (LIQUID/GAS)
SIZE
NOMINAL HEATING CAPACITY
NOMINAL TOTALINPUT POWER
POWER SOURCE
MODELOUTDOOR UNITMASTER UNIT+SLAVE UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
5MDS 500BR
5MDS 250BRM + 5MDS 250BRS
457,208
134,000
504,976
148,000
41,800
39,000
5MDS 500B5MDS 250BM + 5MDS 250BS
457,208
134,000
41,800
380 - 415 / 3 / 50
R410a
65
1840 / 72.4
3990 / 129.5840 / 33.0
1220 / 2690Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
3056 x 4 / 6474 x 4
1528 x 4 / 3237 x 4
50.0 / 110.2
5MDS 480BR
5MDS 240BRM + 5MDS 240BRS
436,736
128,000
484,504
142,000
39,600
37,000
5MDS 480B5MDS 240BM + 5MDS 240BS
436,736
128,000
39,600
380 - 415 / 3 / 50
R410a
65
1840 / 72.4
3990 / 129.5840 / 33.0
1200 / 2646Flare / Brazed
19.1 / 3/4
41.3 / 1 5/8
3056 x 4 / 6474 x 4
1528 x 4 / 3237 x 4
48.0 / 105.8
5MDS 460BR
5MDS 240BRM + 5MDS 220BRS
416,264
122,000
464,032
136,000
37,500
35,400
5MDS 460B5MDS 240BM + 5MDS 220BS
416,264
122,000
37,500
380 - 415 / 3 / 50
R410a
65
1840 / 72.4
3990 / 129.5840 / 33.0
1190 / 2624Flare / Brazed
19.1 / 3/4
41.3 / 1 5/846.0 / 101.4
3056 x 4 / 6474 x 4
1528 x 4 / 3237 x 4
Btu/h
W
Btu/h
W
W
W
Btu/h
W
W
V/Ph/Hz
l/s / cfm
l/s / cfm
dB(A)
mm/in
mm/inmm/inkg/lb
mm/inmm/inkg/lb
5MDS-BR
R-410A5
R-410A6
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) FOR M5CKD 020/025 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA. FOR M5CKD 030/040/050 A, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.
IND
OO
R U
NIT
M5CKD-A
LIQUID
GAS
NOMINAL TOTAL INPUT POWER
HIGH
MEDIUM
HEIGHT
SOUND PRESSURE LEVEL (H/M/L)
DEPTH
PIPE CONNECTION
TYPE
SIZE
INDOOR MODEL
LOW
POWER SOURCE
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
WIDTH
AIR FLOW
WEIGHT (UNIT + PANEL)
UNIT DIMENSION ( ) - WITH PANEL
M5CKD 020A M5CKD 025A M5CKD 030A M5CKD 040A M5CKD 050A
19100 22200 30700 38200 47800
5600 6500 9000 11200 14000
21500 25200 34100 42700 54600
6300 7400 10000 12500 16000
35 45 60 83 120
349 / 740 368 / 780 415 / 880 467 / 990 491 / 1040
297 / 630 311 / 660 349 / 740 406 / 860 448 / 950
283 / 600 283 / 600 321 / 680 359 / 760 411 / 870
42 / 39 / 37 45 / 42 / 40 49 / 45 / 43 51 / 48 / 46 53 / 52 / 50
31 + 4 / 68.3 + 8.8 32 + 4 / 70.5 + 8.8 35 + 4 / 77.2 + 8.8 38 + 4 / 83.8 + 8.8 40 + 4 / 88.2 + 8.8
6.4 / 1/4 6.4 / 1/4 9.5 / 3/8 9.5 / 3/8 9.5 / 3/8
12.7 / 1/2 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8 15.9 / 5/8
820 (930) / 32.2 (36.6)
220-240/1/50
335 (378) / 13.2 (14.9)
820 (930) / 32.2 (36.6)
FLARE VALVE
Btu/h
W
Btu/h
W
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
M5CKD-C
LIQUID
GAS
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
UNIT WEIGHT (UNIT + PANEL)
PIPE CONNECTION
TYPE
SIZE
DEPTH
LOW
UNIT DIMENSION ( ) - WITH PANEL
IND
OO
R U
NIT
POWER SOURCE
AIR FLOW
HIGH
SOUND PRESSURE LEVEL (H/M/L)
HEIGHT
WIDTH
INDOOR MODEL
MEDIUM
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER
M5CKD 010C M5CKD 015C M5CKD 020C
9600 12300 19100
2800 3600 5600
10900 13600 21500
3200 4000 6300
16 18 22
189 / 400 194 / 410 212 / 450
184 / 390 184 / 390 203 / 430
175 / 370 170 / 360 194 / 410
44 / 43 / 42 44 / 42 / 41 47 / 46 / 44
22 + 2 / 48.5 + 4.4 23.2 / 50.7 + 4.4 23 + 2 / 50.7 + 4.4
FLARE VALVE
6.4 / 1/4
9.5 / 3/8 12.7 / 1/2 12.7 / 1/2
220 - 240 / 1 / 50
250 (295) / 9.8 (11.6)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
FLARE VALVE
Btu/h
W
Btu/h
W
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.
M5CMD-E
LIQUID
GAS
LOW
NOMINAL COOLING CAPACITY
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
HIGH
MEDIUM
NOMINAL HEATING CAPACITY
POWER SOURCE
PIPE CONNECTION
TYPE
SIZE
UNIT WEIGHT
WIDTH
HEIGHT
DEPTH
INDOOR MODEL
IND
OO
R U
NIT
NOMINAL TOTAL INPUT POWER
UNIT DIMENSION
M5CMD 015E M5CMD 020E M5CMD 025E M5CMD 028E
12300 19100 22200 27300
3600 5600 6500 8000
13600 21500 25200 30700
4000 6300 7400 9000
79 101 109 150
240 / 508 245 / 520 274 / 580 293 / 620
182 / 386 217 / 460 250 / 530 269 / 570
165 / 350 192 / 406 231 / 490 245 / 520
46 / 38 / 35 50 / 43 / 41 53 / 51 / 49 56 / 51 / 44
26 / 57 27 / 60 27 / 60 28 / 62
9.52 / 3/8
218 / 8.58
1080 / 42.52
630 / 24.80
220 - 240 / 1 / 50
FLARE VALVE
12.7 / 1/2
6.35 / 1/4
15.9 / 5/8
Btu/h
W
Btu/h
W
W
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
dBA
mm/in
mm/in
mm/in
kg/lb
mm/in
mm/in
IND
OO
R U
NIT
M5CMD-D/C
LIQUID
GAS
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT.
PIPE CONNECTION
TYPE
SIZE
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
AIR FLOW
HIGH
MEDIUM
LOW
NOMINAL TOTAL INPUT POWER
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
INDOOR MODEL M5CMD 040D M5CMD 050D M5CMD 062C
Btu/h 38200 47800 56000
W 11200 14000 16400
Btu/h 42700 54600 63100
W 12500 16000 18500
W 153 171 327
V/Ph/Hz
l/s / CFM 477 / 1010 491 / 1040 732 / 1550
l/s / CFM 420 / 890 448 / 950 623 / 1320
l/s / CFM 368 / 780 387 / 820 472 / 1000
dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46
mm/in 285 / 11.2
mm/in 1903 / 74.9
mm/in 680 / 26.8
kg/lb 85 / 187.4
mm/in
mm/in 19.1 / 3/4
670 / 26.30
220 - 240 / 1 / 50
70 / 154.3
249 / 9.80
FLARE VALVE
9.52 / 3/8
15.9 / 5/8
1714 / 67.40
Btu/h 9600 12300 19100 22200 27300
W 2800 3600 5600 6500 8000
Btu/h 10900 13600 21500 25200 30700
W 3200 4000 6300 7400 9000
W 65 96 135 152 300
V/Ph/Hz
l/s / CFM - - - - 401 / 850
l/s / CFM 142 / 300 241 / 510 330 / 700 345 / 730 382 / 810
l/s / CFM 123 / 260 208 / 440 321 / 680 340 / 720 363 / 770
l/s / CFM 104 / 220 170 / 360 293 / 620 274 / 580 335 / 710
EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 49 / 39 / 29(0.2 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.3 / 0.2 / 0.1) (0.2 / 0.2 / 0.1) (0.4 / 0.3 / 0.3 / 0.2)
49 / 39 / 20 64 / 58 / 34 55 / 39 / 29 98 / 78 / 68 / 59
dBA 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 44 / 41 / 38 / 34
mm/in 285 / 11.22
mm/in 765 / 30.12 905 / 35.63 1065 / 41.93 1200 / 47.24 1007 / 39.65
mm/in 600 / 23.62
kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 38 / 84
LIQUID mm/in 9.5 / 3/8
GAS mm/in 9.5 / 3/8
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
220 - 240 / 1 / 50
PIPE CONNECTION
TYPE
SIZE15.9 / 5/8
WEIGHT
UNIT DIMENSION
LOW
SOUND PRESSURE LEVEL (SH/H/M/L)
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
HIGH
MEDIUM
NOMINAL TOTAL INPUT POWER
POWER SOURCE
AIR FLOW
SUPER HIGH
WIDTH
HEIGHT
DEPTH
INDOOR MODEL
FLARE VALVE
411 / 16.18
6.4 / 1/4
12.7 / 1/2
261 / 10.28
Btu/h 30700 34100 38200 47800 56000
W 9000 10000 11200 14000 16400
Btu/h 34100 38200 42700 54600 63100
W 10000
460
11200 12500
510
16000 18500
W 503 515 659
V/Ph/Hz
l/s / CFM 604 / 1280 675 / 1430 812 / 1720
l/s / CFM 547 / 1160 623 / 1320 732 / 1550
l/s / CFM 496 / 1050 580 / 1230 632 / 1340
l/s / CFM 434 / 920 533 / 1130 552 / 1170
EXTERNAL STATIC PRESSURE (SH/H/M/L) Pa (in.wg.) 118 / 96 / 78 / 61 (0.5 / 0.4 / 0.3 / 0.2) (0.5 / 0.4 / 0.3 / 0.2) (0.6 / 0.5 / 0.4 / 0.3) (0.6 / 0.5 / 0.4 / 0.3)
147 / 126 / 109 / 92 147 / 120 / 90 / 69
dBA 52 / 49 / 48 / 45
566 / 1200
486 / 1030
406 / 860
349 / 740
120 / 86 / 64 / 45(0.5 / 0.3 / 0.3 / 0.2)
52 / 49 / 48 / 45 54 / 53 / 52 / 51
628 / 1330
571 / 1210
491 / 1040
425 / 900
120 / 98 / 74 / 54
51 / 49 / 45 / 41 54 / 52 / 50 / 46
mm/in 378 / 14.88 305 / 12.0 378 / 1488 378 / 14.9 378 / 14.9
mm/in 929 / 36.57 1302 / 51.3 1045 / 14.14 1299 / 51.1 1499 / 59.0
mm/in 514 / 21.3 638 / 25.1 541 / 21.3 541 / 21.3 541 / 21.3
kg/lb 39 / 86 41 / 90 42 / 92.6 54 / 119 62 / 137
LIQUID mm/in
GAS mm/in 19.05 / 3/4
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOORb) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
220 - 240 / 1 / 50
AIR FLOW
LOW
POWER SOURCE
HIGH
PIPE CONNECTION
TYPE
SIZE
DEPTH
WEIGHT
UNIT DIMENSION
9.5 / 3/8
15.9 / 5/8
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
MEDIUM
SUPER HIGH
NOMINAL TOTAL INPUT POWER
HEIGHT
SOUND PRESSURE LEVEL (SH/H/M/L)
WIDTH
INDOOR MODEL
FLARE VALVE
IND
OO
R U
NIT
IND
OO
R U
NIT
M5CCD-C
M5CCD 010C M5CCD 015C M5CCD 020C M5CCD 025C M5CCD 028C
M5CCD -C
M5CCD 030C M5CCD 038C M5CCD 040C M5CCD 050C M5CCD 060C
R-410A7