Alderley Application Notes Crude Oil Metering Project Name: Mangala Associated Facilities Project - Storage Tanks & Export System Location: Barmer, Rajasthan, India EPC Contractor/Consultants: TATA Projects Limited End User: Cairn India Limited Scope of Application The scope of supply for this package includes a crude oil metering system and prover, consisting of 3 x 50% 10” ANSI 600# meter streams with 6” ultrasonic meters, 20” bi-directional prover with a fast loop sampling system and metering control system. India

Alderley...API MPMS Chp. 21: Flow Measurement using Electronic Metering Systems ISO 5168: Measurement of fluid flow - Estimation of uncertainty of a flow-rate measurement • 3 x Meter

  • Upload
    others

  • View
    27

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Alderley...API MPMS Chp. 21: Flow Measurement using Electronic Metering Systems ISO 5168: Measurement of fluid flow - Estimation of uncertainty of a flow-rate measurement • 3 x Meter

Alderley

Technical excellence: delivered

Application NotesCrude Oil Metering

Project Name:Mangala Associated Facilities Project - Storage Tanks & Export System

Location:Barmer, Rajasthan, India

EPC Contractor/Consultants:TATA Projects Limited

End User:Cairn India Limited

Scope of ApplicationThe scope of supply for this package includes a crude oil metering system and prover, consisting of 3 x 50% 10” ANSI 600# meter streams with 6” ultrasonic meters, 20” bi-directional prover with a fast loop sampling system and metering control system.

India

Page 2: Alderley...API MPMS Chp. 21: Flow Measurement using Electronic Metering Systems ISO 5168: Measurement of fluid flow - Estimation of uncertainty of a flow-rate measurement • 3 x Meter

Alderley

www.alderley.com

Rev. 06.01.17

Applicable Standards

API MPMS Chp. 1: Vocabulary

API MPMS Chp. 4: Proving Systems

API MPMS Chp. 5: Liquid Metering

API MPMS Chp. 6: Metering Assemblies

API MPMS Chp. 21: Flow Measurement using Electronic Metering Systems

ISO 5168: Measurement of fluid flow - Estimation of uncertainty of a flow-rate measurement

• 3 x Meter streams

• 6” 600# RF ultrasonic meters

• 6” 600# Flow conditioners

• 12” 600# RF gear operated ball and globe valves

• 10” 600# RF ball valves, pneumatically actuated

• 10” 600# RF basket type strainers

• Temperature gauges

• Temperature transmitter, c/w 4 wire PRT, 4-20mA

• Sampling system with liquid densitometer

• 20” Prover system

Main Equipment