1
A UTC Fire & Security Company Effective: January 2012 K-75-015 Series MBA Motorized Bells by Kidde FEATURES Agency approvals include: UL, ULC, CSFM, NYMEA 6-inch and 10-inch shell sizes, 24 Vdc models Mounting options for surface, semi-flush, outdoor, and concealed conduit installation Red smooth finish to improve appearance and durability DESCRIPTION Potter ® manufactured Motor Bells provide a superior engineered notification product for fire and life safety alarm systems. The motorized bells are designed for public mode signaling in accordance with the latest edi- tion of NFPA 72. The bells produce a long and continu- ous higher dBA ringing sound at low current draw; low frequency shells for better audibility, low RFI noise and high torque. A permanent magnet motor is incorporated for durable, reliable performance. MOUNTING The unit mounts on a standard 4-in. (101 mm) square electrical backbox for indoor applications. Other mount- ing options are provided in the Mounting Options table below. Series MBA Motorized Bells ORDERING INFORMATION Model Number Part Number Mounting Options SFP-R 75-000000-005 F BB-R 75-000000-006 C AP-R 75-000000-007 G WBB-R 75-000000-008 E Part Number Input Voltage Shell Size Max. RMS Operating Current (mArms) Min. Sound Output (dBA at 10 ft. per UL464) Min. Sound Output (dBA at 10 ft. per ULC-S525) Regulated 12 Vdc (per UL464) Regulated 12 VFWR (per UL464) Regulated 12 Vdc (per ULC-S525) Regulated 12 VFWR (per ULC-S525) MBA-6-24 24 Vdc 6 in. (150 mm) 13.5 24.5 17.0 30.0 75.6 at 8Vdc 95.0 at 8Vdc MBA-10-24 24 Vdc 10 in. (250 mm) 34.0 46.0 34.0 46.0 79.1 at 8Vdc 92.0 at 8Vdc This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-75-015 Rev AA © 2012 Kidde-Fenwal Inc. Kidde is a registered trademark of Kidde-Fenwal Inc. Potter is a registered trademark of Potter Electric Signal Company, LLC Kidde Fire Systems UTC Climate | Controls | Security 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresystems.com SFP Standard 4” square backbox F. SEMI-FLUSH C. SURFACE BB G. CONCEALED CONDUIT AP E. OUTDOOR WBB Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464 and ULC-S525. Due to changes in UL Standard 464 and ULC-S525, all minimum dBA ratings are calculated at minimum operating voltage. Typical operating dBA will be higher. UL temperature range is -40 to 150°F (-40 to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation.

Alarm Bell 2f

Embed Size (px)

DESCRIPTION

ALARM BELL

Citation preview

Page 1: Alarm Bell 2f

A UTC Fire & Security Company

Effective: January 2012K-75-015

Series MBA Motorized Bellsby Kidde

FEATURES

• Agency approvals include: UL, ULC, CSFM, NYMEA

• 6-inch and 10-inch shell sizes, 24 Vdc models

• Mounting options for surface, semi-flush, outdoor, and concealed conduit installation

• Red smooth finish to improve appearanceand durability

DESCRIPTION

Potter® manufactured Motor Bells provide a superiorengineered notification product for fire and life safetyalarm systems. The motorized bells are designed forpublic mode signaling in accordance with the latest edi-tion of NFPA 72. The bells produce a long and continu-ous higher dBA ringing sound at low current draw; lowfrequency shells for better audibility, low RFI noise andhigh torque. A permanent magnet motor is incorporatedfor durable, reliable performance.

MOUNTINGThe unit mounts on a standard 4-in. (101 mm) squareelectrical backbox for indoor applications. Other mount-ing options are provided in the Mounting Options tablebelow.

Series MBA Motorized Bells

ORDERING INFORMATION

Model Number Part NumberMounting Options

SFP-R 75-000000-005 F

BB-R 75-000000-006 C

AP-R 75-000000-007 G

WBB-R 75-000000-008 E

Part Number Input Voltage Shell SizeMax. RMS Operating Current (mArms) Min. Sound Output

(dBA at 10 ft. per UL464)

Min. Sound Output (dBA at 10 ft. per

ULC-S525)Regulated 12 Vdc (per UL464)

Regulated 12 VFWR (per UL464)

Regulated 12 Vdc (per ULC-S525)

Regulated 12 VFWR (per ULC-S525)

MBA-6-24 24 Vdc 6 in. (150 mm)

13.5 24.5 17.0 30.0 75.6 at 8Vdc 95.0 at 8Vdc

MBA-10-24 24 Vdc 10 in. (250 mm)

34.0 46.0 34.0 46.0 79.1 at 8Vdc 92.0 at 8Vdc

This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work correctly.If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000.

K-75-015 Rev AA © 2012 Kidde-Fenwal Inc.

Kidde is a registered trademark of Kidde-Fenwal Inc. Potter is a registered trademark of Potter Electric Signal Company, LLC

Kidde Fire SystemsUTC Climate | Controls | Security400 Main StreetAshland, MA 01721Ph: 508.881.2000Fax: 508.881.8920www.kiddefiresystems.com

SFP

Standard4” squarebackbox

F. SEMI-FLUSH C. SURFACE

BB

G. CONCEALED CONDUIT

AP

E. OUTDOOR

WBB

Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464 and ULC-S525. Due to changes in UL

Standard 464 and ULC-S525, all minimum dBA ratings are calculated at minimum operating voltage. Typical operating dBA will be higher. UL temperature range is -40 to 150°F (-40 to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation.