«AKSAISPETSMONTAZH» COMPANY PRESENTATION Versatile, up-to-date, high-technology block-modules

Embed Size (px)

Citation preview

AKSAISPETSMONTAZH COMPANY PRESENTATIONVersatile, up-to-date, high-technology block-modules

Content1. Block modules function 2. Climatic service conditions of multi-functional mobile units and block - modules.3. Technical specifications.4. Additional furnishing.5. Transportation.6. Storage.7. Installation.8. Mobility and supervision9. Licensing documentation.10. Photo gallery.11. Contact details.

Block modules functionMobile buildings (inventory), hereinafter referred to as "Module" - a self-contained buildings (block - modules), 100% of factory assembled with increased comfort and amenities for persons residing outside of and in population locality. Functionality the modules are divided into the following types:offices;accommodations;kitchen and canteen;hotel complex;camps;hypermarkets;banks;personnel facilities MVD, ES, Minoboronysecurity checkpoints and block-modules;dispatching office and command posts;premises utilities;first-aid posts, toilet rooms and shower-baths;warehouses for materials and tools;workshopsheating units.School and preschool facilities.

Climatic service conditions of multi-functional mobile units and block - modules.climatic service conditions of multi-functional mobile units and block - modules. :the direct effect of atmospheric precipitation in the form of fog, rain, snow;ambient temperature from -40 to +50 degrees ;relative air humidity till 60% at 20 degrees C; snow load 1,00 ;wind load 0,48 ;seismicity of the area using up to 10 points

Technical specificationsFire Safety the block modules are manufactured of the facing materials and lagging that ensure III a class of fire resistant according to SNIP RoK 2.02-05;Block modules framework made of light steel structural metalwork bent as C - shaped profiles according to ST AO 04768086-02-2008 with two belts reinforced by the upper and lower perimeter is made of hot channel 14 according to GOST 8240. The belt of the upper perimeter is corrugated beam is increased by ridged beams if the width of the span of the module is more than 12 mWalls:Inner lathing - made of cold-formed III shaped profiles and outer coating- steel galvanized corrugated sheet 0.7 mm thick (color of sheet is determined by the Buyer) in accordance with ST AO 04768086-02-2008;heat-insulation - 100 mm lagging ISOVER;Inner coating types of finishing- plastic panels, MDF panels, galvanized siding metal for industrial purpose buildings;vapor sealing - PVC film.Roof:flat;Inner lathing made of cold-formed III-shaped profiles and outer coating stainless steel sheet 75378 thickness 0,7 mm according to 04768086-02-200, joints are seamed to the castle like "seam";The water flow is organized to the ends of the module; Heat-insulation - 100 mm, lagging ISOVER;Inner coating types of covering- plastic panels, MDF panels, galvanized siding metal for industrial purpose buildings;vapor sealing - PVC film.

Technical specificationsFloorInner lathing - is made of cold-formed -shaped profiles and substrate - stainless steel sheet h4 galvanized , 0.7 mm thick according to 04768086-01-2008;Heat-insulation - 100 mm, lagging ISOVER;The top layer - in a typical performance - 30 mm board, OSB 18 mm, cover - linoleum. Options: - 4mm corrugated metal for industrial purpose buildings;vapor sealing - file.Interior bulkhead :Vertical and horizontal connections of cold-formed C-shaped profiles according to ST AO 04768086-02-2008; Lathing made of cold III shaped profiles according to ST AO 04768086-02-2008 on both sides;Heat-insulation -- 100 mm, lagging ISOVER;Coating on two sides types of finishing- plastic panels, MDF panels, galvanized siding metal for industrial purpose buildings;Windows - windows profile of complex opening are made of PVC profile with a 2-pane glass.Doors:external metal, heat-insulated;Internal doors plastic PVC, color.

Technical specificationsElectrical system of block modules:Power supply 220-380 , 50 hz with solid earthed neutral;Power supply is made in accordance with the requirements of ESR-99. According to power supply degree electro receiver belongs to the third category;Input voltage 220V as per scheme "F + N + PE," where the PE is protective earthing conductor;Wiring is made by closed method in cable channels. Switches and power supply socket 10A built-in type with vanishing conductor are installed according to the Schemes;Lights to be fluorescent fixture of enclosed type; Outdoor lighting is not provided;Electrical power of the building - from 5 kW, the upper limit of the power is not limited.All changes in power supply of the building at the request of the buyer to be agreed separately.Communications networks - computer, telephone and television networks wiring to be conformed according to working project.Water supply:Centralized on external sources of hot and cold water;Independent - individual tanks for storage of water from 50 to 1000 liters, installed in the module. Water supply is provided by individual automatic water supply stations in each module. Water supply network to be wired using metal plastic pipes.

Drainage - PVC piping sections 50 and 100 with a tap to the sewer system. Heating system:central - from the layout of the building heating system with the installation of radiators in each room independent - electrical oil heaters Ventilation - natural ventilation - window panes .

Additional furnishing. Possible additional furnishing : As agreed upon with Customer it is possible to install additional equipmentartificial ventilation exhaust fan ;built-in air conditioner split system winter -summerkitchen equipment - cooking appliance, washer, refrigerator, kitchen furniture;plumbing equipment hot water boiler, sinks, toilets, urinals, showers, washing machine;furniture and office equipment and premises, depending on the purpose of the building;satellite TV antenna.Modules can be used both separately and in combination with several buildings, creating a complex;It is possible to create 2 floor complexes from Modules with their interconnection;It is possible to redevelopment the modules according to customer request installation of extra windows, manufacturing of interior walls, installation of heating and drainage.

TransportationTransportation.transportation of block-module can be realized by any type of transport in accordance with the rules applicable to it;the building is not classified as a dangerous according to GOST 19433combined portage of buildings only with loads, related to the safe category per GOST 12.1.004module to be transported without packing;interior and exterior doors shall be closed, locked and sealed ;loading of module to truck is carried out using mounting tabs only;transportation of buildings with people inside is not allowed;to ensure the sustainability and security of the buildings during transportation by road, speed of the car shall be limited on asphalt road or other hard surface up to 50 km / h on roads with gravel and cobble coating - up to 30 km / h, on dirt roads - up to 15 km / hWarning! When transporting a mobile building by motor transport it is necessary to install support-bars (plates) . (See Fig. 3)

StorageStorage.combined storage of buildings only with the materials relating to category safe in accordance with GOST 12.1.004 storage of module to be carried out on storage conditions 7 and 8 GOST 15150, doors, windows and other openings have to be closed and modules to be protected from outsider penetration;modules should be put on the pads during storage;the platform for storage of inventory buildings in the open air has to be smooth, cleared and provide water drainage;the period of storage shouldnt exceed 6 months from the date of delivery to storage. If after the deadline the modules not to be put in operation, it is necessary to perform scheduled maintenance and repair providing their safety.

InstallationInstallation.installation of block module is carried out using mounting tabs only;block module shall be installed on a flat surface using the pads horizontally; modules may be installed on each other no more than two storeys;Before connecting the unit to the mains supply, it is necessary to provide reliable connection of the module frame to the external groundingProhibition! To prevent damage of block-module bottom casing it is strictly forbidden to install a module unit on the ground without pads or install support blocks not under a power belt of the module. (see Fig..1)Warning! Module shall be installed horizontally. For installation use the pads. The support units shall be installed in accordance with the scheme issued by the manufacturer. Supporting area of the blocks determined by the density of the soil. (see Fig. 2)Warning! modules may be installed on each other no more than two storeys (See Fig. 4)Warning! Before connecting the module to the mains supply, it is necessary to provide reliable accession of module framework to an external contour of grounding through a bolt on the bottom belt of a back facade (Fig.5)

Mobility and supervision.Mobility and design scheme of mobile buildingsFrom separate mobile buildings (block-modules) it is possible to build rotational villages and infrastructure of settlements at minimum expenses on their installation, on the prepared foundation and on assembling works on docking of mobile buildings in blocks. The indicated works are carried out under the supervision and with participation at chief-editing specialists of AksaiSpetsMontazh LLP. If necessary, mobile buildings are able to follow the dismantling and moving them to other industrial sites. Supervision"AksaiSpetsMontazh" LLP provides on place of mobile buildings exploitation the presence of experts for the period agreed with the Purchaser for following works:management of personnel, installing of mobile buildings on foundations and assembly of functional units from mobile buildings. All necessary materials handling equipment, transportation, equipment and manpower for installation of mobile buildings are provided by Customer;sealing of joints of roof, walls, floors and other works related to the joining of the individual mobile buildings into functional block -modules;Installation works on internal engineering networks and equipping of mobile buildings and functional units in the amounts established by the project documentation (power supply, water supply, drainage, ventilation, air conditioning); signing of act of delivery the mobile buildings in operation.

Photo gallery offices

Photo gallery accommodations

Photo gallery canteen

Photo gallery hotel complexes

Photo gallery rotational camp

Photo gallery hypermarkets

Photo gallery banks

Photo gallery personnel facilities MVD, ES, Minoborony

Photo gallery security checkpoints and block-modules

Photo gallery dispatching office and command posts

Photo gallery premises utilities

Photo gallery first-aid posts, toilet rooms and shower-baths

Photo gallery warehouses for materials and tools

Photo gallery warehouses

Photo gallery Heating units

Photo gallery School and preschool facilities.

Contact detailsRepublic of Kazakhstan, West Kazakhstan oblast,t. Aksai, industrial zone, Tel: 9-29-40 (gas line) Tel/fax: (71133) 36076E mail: [email protected] ,[email protected] Website: www.asm.kz