18
> Ventilation Air Conditioning Refrigeration Heating 22 º C Inside OUTSIDE HUMIDITY PROVIDED BY HEINEN & HOPMAN 35 C 90% PRODUCTS Air in- & outlets

Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

>

Ventilation Air Conditioning RefrigerationHeating

22ºCInside

OUTSIDEHUMIDITY

PROVIDED BYHEINEN & HOPMAN

35 C

90%

productsAir in- & outlets

Page 2: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

air in- & outlets

applicationThe air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems.

There are different types of air in- & outlets with different sizes and options:- Goosenecks- Elbows- Louvres- Mushrooms- Mist eliminators

The head openings are available in different materials:• Goosenecks / Elbows - Hot-dip galvanized steel• Louvres - Hot-dip galvanized steel - Stainless steel 316L• Mushrooms - Primed and painted steel - Hot-dip galvanized steel - Stainless steel 316L• Mist eliminator - Aluminum

to offer complete operational

security to those who ensure

ours

“ “

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Page 3: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Goosenecks a

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 225 250 275 300 310 325 350 375 400 450 500 535

**H 900 900 900 900 900 900 900 900 900 900 900 900

ØD1xt1 89.0x8.0 114.3x8.0 139.7x8.0 168.3x8.0 177.8x8.0 193.7x8.0 219.1x8.0 244.5x8.0 273.0x8.0 323.9x8.8 377.0x8.8 406.4x10.0

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * Dimension can be changed on request. ** Dimension can be changed on request (if H>900 must be specially strengthened.

==

8

Socket

Gooseneck

8

60x8

**H

A

*200

Nongalvanized

∅D1xT1H.I.P.

*120

Ratproofwire 25x23

2x2

MAX. 80

Sock

et

**H

**H

**H

Nongalvanized

Nongalvanized

Nongalvanized

Detail socket

Ratproof wireFree passage 78%

Option 1 Option 2

Option 3

Page 4: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Goosenecks B

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 225 250 275 300 310 325 350 375 400 450 500 535

**H 900 900 900 900 900 900 900 900 900 900 900 900

ØD1xt1 89.0x8.0 114.3x8.0 139.7x8.0 168.3x8.0 177.8x8.0 193.7x8.0 219.1x8.0 244.5x8.0 273.0x8.0 323.9x8.8 377.0x8.8 406.4x10.0

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * Dimension can be changed on request. ** Dimension can be changed on request (if H>900 must be specially strengthened.

==

8

Socket

Gooseneck

8

60x8

**H

A

*200

nongalvanized

∅D1xT1H.I.P.

*120

Ratproofwire 25x23

2x2

Sock

et

**H

**H

**H

nongalvanized

nongalvanized

nongalvanized

Detail socket

Ratproof wireFree passage 78%

Option 1 Option 2

Option 3

Page 5: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Goosenecks C

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 225 250 275 300 310 325 350 375 400 450 500 535

**H 900 900 900 900 900 900 900 900 900 900 900 900

ØD1xt1 89.0x8.0 114.3x8.0 139.7x8.0 168.3x8.0 177.8x8.0 193.7x8.0 219.1x8.0 244.5x8.0 273.0x8.0 323.9x8.8 377.0x8.8 406.4x10.0

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * Dimension can be changed on request. ** Dimension can be changed on request (if H>900 must be specially strengthened.

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

==

8

Socket

Gooseneck

8

60x8

**H

A

*200

Nongalvanized

∅D1xT1H.I.P.

*120

Ratproofwire 25x23

2x2

MAX. 80

Sock

et

**H

**H

**H

Nongalvanized

Nongalvanized

Nongalvanized

Detail socket

Ratproof wireFree passage 78%

Option 1 Option 2

Option 3

Page 6: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

elbow a

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 170 185 195 210 215 225 235 250 265 290 315 330

ØD1xt1 89.0x3.6 114.3x3.6 139.7x4.0 168.3x4.5 177.8x5.0 193.7x5.6 219.1x6.3 244.5x6.3 273.0x6.3 323.9x7.1 377.0x8.8 406.4x8.8

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * N=Natural / M=Mechanical ** Dimension can be changed on request.

Ratproofwire

MAX. 80

Non galvanized

A

**20

0

∅D1xT1 T1

**120

H.I.P

.

25x23

2x2

60x8

Sock

et

A

Nongalvanized

Nongalvanized

Nongalvanized

A A

8

= =

Socket

Elbow

Detail socket

Option 1 Option 2

Option 3

Ratproof wireFree passage 78%

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Page 7: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

elbow B

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 170 185 195 210 215 225 235 250 265 290 315 330

ØD1xt1 89.0x3.6 114.3x3.6 139.7x4.0 168.3x4.5 177.8x5.0 193.7x5.6 219.1x6.3 244.5x6.3 273.0x6.3 323.9x7.1 377.0x8.8 406.4x8.8

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * N=Natural / M=Mechanical ** Dimension can be changed on request.

Ratproofwire

MAX. 80

Non galvanizedA

**20

0

∅D1xT1 T1

**120

H.I.P

.

25x23

2x2

60x8

Sock

et

A

Nongalvanized

Nongalvanized

Nongalvanized

A A

8

= =

Socket

Elbow

Detail socket

Option 1 Option 2

Option 3

Ratproof wireFree passage 78%

Page 8: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

elbow C

size Dn 75 Dn 100

Dn 125

Dn 150

Dn 160

Dn 175

Dn 200

Dn 225

Dn 250

Dn 300

Dn 350

Dn 375

a 170 185 195 210 215 225 235 250 265 290 315 330

ØD1xt1 89.0x3.6 114.3x3.6 139.7x4.0 168.3x4.5 177.8x5.0 193.7x5.6 219.1x6.3 244.5x6.3 273.0x6.3 323.9x7.1 377.0x8.8 406.4x8.8

H.i.P. Ø110 Ø135 Ø160 Ø190 Ø200 Ø215 Ø240 Ø265 Ø295 Ø345 Ø400 Ø430

socket Ø107 Ø132 Ø157 Ø187 Ø197 Ø212 Ø237 Ø262 Ø292 Ø342 Ø397 Ø427

Toggle type: M12 (from DN200 - M16)

Material: Hot-dip galvanized steel, Rubber gasket, Hinge and toggle - Stainless steel (eye nut - brass)

Option: * N=Natural / M=Mechanical ** Dimension can be changed on request.

Ratproofwire

MAX. 80

Non galvanized

A

**20

0

∅D1xT1 T1

**120

H.I.P

.

25x23

2x2

60x8

Sock

et

A

Nongalvanized

Nongalvanized

Nongalvanized

A A

8

= =

Socket

Elbow

Detail socket

Option 1 Option 2

Option 3

Ratproof wireFree passage 78%

Page 9: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

louvre a

Louvre without hatchLouvre thickness 2 mmFrame L 40x40x5 mmRat-proof wire Type A, B, C (according to requirements)

Mounting holes for M12 stainless-steel bolts mounted with plates (option: pitch array 7-8 x d)Note: in accordance with DIN 83 408, 83 409

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Louvre with weather tight hatchLouvre thickness 2 mmFrame L 50x50x5 mm, L60x60x5 mm (according to W x H)Hatch thickness 5 - 8 mm (according to W x H as per class)Hinge side Left, right, top, bottom (according to requirements)Toggle type M12, M16, M20 (according to W x H)Toggle quantity 1 ~ 6 (according to W x H)Rat-proof wire Type A, B, C (according to requirements)Material - Louvre / Fame / Rat-proof wire: 316L Stainless steel - Pins / Eye bolts: Stainless steel - Toggles: Brass - Hatch: Weld-painted or hot-dip galvanized steel

RATPROOF WIRE:

TYPE A

TYPE B

TYPE C

Free passage 78%.

Free passage 82%.

Free passage 78%.

Page 10: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

louvre B

Louvre without hatchLouvre thickness 3 mmFrame L 60x40x5 mmRat-proof wire Type A, B, C (according to requirements)

Mounting holes for M12 stainless-steel bolts mounted with plates (option: pitch array 7-8 x d)Note: in accordance with DIN 83 408, 83 409

Louvre with weather tight hatchLouvre thickness 3 mmFrame L 60x40x5 mm, L60x60x5 mm (according to W x H)Hatch thickness 5 - 8 mm (according to W x H as per class)Hinge side Left, right, top, bottom (according to requirements)Toggle type M12, M16, M20 (according to W x H)Toggle quantity 1 ~ 6 (according to W x H)Rat-proof wire Type A, B (according to requirements)Material - Louvre / Fame / Rat-proof wire: 316L Stainless steel - Pins / Eye bolts: Stainless steel - Toggles: Brass - Hatch: Weld-painted or hot-dip galvanized steel

RATPROOF WIRE:

TYPE A

TYPE B

Free passage 78%.

Free passage 70%.

Page 11: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

louvre C

Louvre without hatchLouvre thickness 3 mmFrame L 80x8 mmRat-proof wire Type A, B (according to requirements)

Mounting holes for M12 stainless-steel bolts mounted with plates (option: pitch array 7-8 x d)Note: in accordance with DIN 83 408, 83 409

Louvre with weather tight hatchLouvre thickness 3 mmFrame Flat 60x8 mmHatch thickness 5 - 8 mm (according to W x H as per class)Hinge side Left, right, top, bottom (according to requirements)Toggle type M12, M16, M20 (according to W x H)Toggle quantity 1 ~ 6 (according to W x H)Rat-proof wire Type A, B (according to requirements)Material - Louvre / Fame / Rat-proof wire: 316L Stainless steel - Pins / Eye bolts: Stainless steel - Toggles: Brass - Hatch: Weld-painted or hot-dip galvanized steel

H

85

75

W

AA-A

A

Ratproof wire

25x23

2x2

12x10

1x1

RATPROOF WIRE:

TYPE A

TYPE B

Free passage 78%.

Free passage 70%.

Page 12: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Mushroom a

Option: Gasket seal / Rat-proof wire. Handwheel can be mounted at the side of the muschroom instead of above the mushroom.Material: Hot-dip galvanized steel Threaded rod, bolts, nuts and cotter pins: Stainless steel Bearing: Brass Wheel: Cast iron (rotation closed clockwise)

Casing and flap steel: 5mm.

type Hu-K-30

Hu-K-40

Hu-K-50

Hu-K-60

Hu-K-70

D1 Ø 317 402 502 602 713

D2 Ø 356 438 541 648 755

D3 Ø 403 488 600 700 811

D4 Ø 800 960 1100 1270 1400

H1 150 200 200 200 200

H2 300 500 500 570 700

H3 350 400 400 400 400

s 3 3 3 3 4

a1 12x 12x 12x 16x 16x

Ø a2 9.5 9.5 9.5 11.5 11.5

H1H2

5

H3

S

D4

A1x∅A2

D1 D2 D3

Detail flange Detail flange

Page 13: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Mushroom B

Option: Gasket seal / Rat-proof wire Hand-wheel can be mounted at the side of the muschroom instead of above the mushroom.Material: Hot-dip galvanized steel Threaded rod, bolts, nuts and cotter pins: Stainless steel Bearing: Brass Wheel: Cast iron (rotation closed clockwise)

Casing and flap steel: 5mm.

type Hu-K-30

Hu-K-40

Hu-K-50

Hu-K-60

Hu-K-70

D1 Ø 317 402 502 602 713

D2 Ø 356 438 541 648 755

D3 Ø 403 488 600 700 811

D4 Ø 800 960 1100 1270 1400

H1 450 500 500 500 500

H2 300 500 500 570 700

H3 500 700 700 700 700

s 3 3 3 3 4

a1 12x 12x 12x 16x 16x

Ø a2 9.5 9.5 9.5 11.5 11.5

10

H3

H2H1

S

D4

D2 D3

A1x∅A2

D1

Detail flange

Detail flange

Page 14: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Mushroom C

type Hu-K-50

Hu-K-60

Hu-K-70

Hu-K-80

Hu-K-90

Hu-K-100

D1 Ø 502 602 713 804 909 1005

D2 Ø 541 648 755 860 971 1080

D3 Ø 600 700 811 928 1033 1129

D4 Ø 1100 1270 1400 1800 1900 2500

H1 350 350 400 450 500 550

H2 500 570 700 750 900 1080

H3 550 550 600 650 750 800

s 3 3 4 5 5 5

a1 12x 16x 16x 16x 16x 16x

Ø a2 9.5 11.5 11.5 11.5 11.5 11.5

Option: Gasket seal / Rat-proof wire. Material: Hot-dip galvanized steel Threaded rod, bolts, nuts and cotter pins: Stainless steel Bearing: Brass

Casing and flap steel: 5mm.

5

H2

8

Closed

Open

H1

H3

D1 D2 D3

Detail Flange

S

A1X∅A2

D4

Detail flange

Page 15: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Mist eliminators

Mist eliminators are used on board ships, yachts and offshore modules to prevent droplets enetering the system downstream. Mist eliminators are available in all variants and dimensions.

The inlet grills of many ventilation systems on board ships are too small or placed close to the water, causing water droplets to be drawn in by the fans and damage to the fans and the machinery downstream. Mist eliminator separate, collect and drain the airborne water droplets from the entering air.

Working principle

The air flow with water droplets approaches the mist eliminator and enters the different flow channels (1) formed between two mist eliminator profiles (2). Because of inertia forces, water droplets impinge on the profiles and are stopped in the first barrier (3) to form a liquid film. Because of gravity forces, the water film is drained to the bottom of each mist eliminator module. Smaller water droplets that do not impinge on the first part of the profiles are accelerated because of a narrower flow channel between two profiles at the barrier. The accelerated water droplets impinge on the latter part of the profiles (4) and are stopped in the second barrier (5). Special means are incorporated in the profiles to prevent water from re-entrainment.

BenefitsCompared to conventional intake grills, our mist eliminators have these benefits:• Higher permissible flow speed: 5 m/s through gross width• The size of the grill can be reduced by a factor 2.5• Low weight due to the use of sea-water-resistant aluminum

and the smaller size• High efficiency: droplets of 20 μm• Low pressure loss

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Page 16: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Mist eliminators without hatch Mist eliminators without hatch according to Lloyd’s and Veritas requirements.

Option: -Material: Sea-water-resistant aluminium frame Casing: AL 57 S Profile: AIMgSi 0.5 Welded flange: AIMg 5 or 8ckwise) Mounting holes ø12mm for stainless steel bolts M10 with nylon rings

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

W (outside)

H (out

side

)

2020

∅12310 310

310

310

AIR

Air inAft. wall

Centre line

Position of blades in misteliminators

A

Air inAft. wall

C

Air inSide wall

B

ForeshipPS

SB

Air inAft. wall

D

W (outside)

H (ou

tside

)

2020

∅12310 310

310310

AIR

Air inAft. wall

Centre line

Position of blades in misteliminators

A

Air inAft. wall

C

Air inSide wall

B

ForeshipPS

SB

Air inAft. wall

D

W (outside)

H (out

side

)

2020

∅12310 310310

310

AIR

Air inAft. wall

Centre line

Position of blades in misteliminators

A

Air inAft. wall

C

Air inSide wall

B

ForeshipPS

SB

Air inAft. wall

D

Page 17: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

Mist eliminator with weather tight hatch The mist eliminators can be supplied with closeable hatch (fire flap) according to Lloyd’s and Veritas requirements.

Option: Aluminium or steel hatchMaterial: Sea-water-resistant aluminium frame Casing: AL 57 S Profile: AIMgSi 0.5 Welded flange: AIMg 5 or 8ckwise) Hinge and toggle: stainless steel (eye nut- brass)

Material: Hatch - weld painted or hot-dip galvanized steel Mounting holes ø12mm for stainless steel bolts M10 with nylon rings For Hatch smaller than 0.5m2, Hinge and Toggle will be standard M12.For Hatch equal or above 0.5m2, Hinge and Toggle will be standard M16.

Note: W- Width H.I.P = W+10 and H+10H - Height Hatch size = W+40 and H+40

Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.

Air inAft. wall

C

Air inAft. wall

D

H (out

side

)Ha

tch

size

H.I.P

.

W (outside)

150 150310

310

310

20

20

∅12

AIR

(L50x50x5)

310

A4SubjectSubject No.

::

Reference No. ::Drawing No. Sheet : of

IMO :Ships Class :

Designer ControllerRev.Units

::

Scale

0Rev. Description Des. Con. Date

Mist EliminatorWithout hatch

Heinen & HopmanStandard

Original-

SN09-05-2014

HARRY09-05-2014

1:16mm

1 1-

-

Material:Frame - Seawater resistant aluminium,Mounting holes ∅12 for stainles steel bolts M10mounted with nylon rings.Mist eliminator with mounting holes is optional version.

Direction of profile - SB (starboard) or PS (port side).

Block nmb. QT Width (W) Height (H) Space to be ventilated- - - - -- - - - -- - - - -- - - - -- - - - -

Direction of profile-----

Page 18: Air In- & Outlets - Heinen & Hopman · The air inlet and outlets are used on installation of neutral ventilation systems for the fresh air intake serving any kind of ventilation systems

www.heinenhopman.com

Heinen & Hopman encourages a more

sustainable world. By providing eco-friendly solutions and serviceswe offer our clients

the option of reducing energy consumption

and thus co2 emissions. Visit

greenmanifest.info for more information.

BrazilT: +5521 3587 4241/4244E: [email protected]

France - la CiotatT: +334 4204 8685E: [email protected]

France - GrasseT: +336 3090 7786 E: [email protected]

GermanyT:+49 4073 1680E: [email protected]

indiaT: +9133 6499 1293E: [email protected]

italyT: +3901 8745 7970E: [email protected]

the netherlands (HQ)T: +313 3299 2500E: [email protected]

the netherlands (rotterdam)T: +317 8890 8050E: [email protected]

norwayT: +47 6919 0900E: [email protected]

Peoples republic of ChinaT: +8621 3253 2896E: [email protected]

Peoples republic of ChinaT: +86 510 8528 1763E: [email protected]

PolandT: +489 1433 1800E: [email protected]

romaniaT: +402 3644 8222E: [email protected]

russiaT: +7 (4012) 308 801E: [email protected]

singaporeT: +65 6897 7879E: [email protected]

south KoreaT: +8270 4901 0000E: [email protected]

spainT: +349 3225 9668E: [email protected]

swedenT: +46 3121 7500E: [email protected]

turkeyT: +9021 6493 8118E: [email protected]

uae (abu Dhabi) T:+971 2550 4147E: [email protected]

uae (Dubai)T: +971 4263 5453E: [email protected]

usa - Fort lauderdale, FloridaT: +195 4463 0110E: [email protected]

usa - Houma, louisiana T: +198 5876 7989E: [email protected]