  • FOR THE COMPLETE VENTILATION SOLUTION

    AIR HANDLING MADE SIMPLE

    NOW AVAILABLE

    IN

    HORIZONTAL

    & VERTICAL

    FORMAT

    LEAKAGE

    CLASS

    THER

    MAL BRIDGIN

    G

    CLASS

    TB1

    DEFLECTION

    CLASS

    D1

  • 029 2085 82002

    AT THE FOREFRONT OF PACKAGED SOLUTIONS FOR OVER 20 YEARS

    Nuaire has been at the forefront of packaged AHUs for over 20 years, designing and

    manufacturing market leading ranges.

    When launched in 2000, Ecosmart Boxer revolutionised the industry by providing the

    best solution for performance and energy efficiency, then enhanced it with the Ecosmart

    plug and play control.

    p Model shown: Horizontal Plate

    Heat Exchanger Unit shown

    split into 3 sections.

    p Model shown: Vertical Plate

    Heat Exchanger Unit shown

    split into 3 sections.

    Fast forward sixteen years and the New Boxer Packaged Solution (BPS) has

    been designed, engineered and tested to provide the most efficient, best

    performing, most compact and easiest to select AHU on the market.

    BPS can be supplied in many configurations to suit the project or application

    and is available with either a high efficiency plate HX (ErP 2018)

    or thermal wheel (ErP 2018). BPS also has options for recirculation,

    heating and cooling upon request.

    BPS offers full control flexibility and is complimented with the new

    Ecosmart Control Platform of Ecosmart Classic, Connect or Adapt

    (with Trend).

    All packaged controls are inbuilt and factory tested by Nuaire.

    LEAKAGE

    CLASS

    THER

    MAL BRIDGIN

    G

    CLASS

    TB1

    DEFLECTION

    CLASS

    D1

  • 3nuaire.co.uk

    m3/s 0 0.75 1.25 1.75 2.25 3.25 4.25 6.0

    BPS-07

    BPS-12

    BPS-17

    BPS-22

    BPS-32

    BPS-42

    BPS-05

    BPS-10

    BPS-15

    BPS-20

    3nuaire.co.uk

    HORIZONTAL UNITS m3/s 0 0.5 1.0 1.5 2.0 2.5 3.0

    Maximum Duty

    VERTICAL UNITS

    BOXER PACKAGED

    SOLUTIONS CONTENTS

    p Model shown: Vertical Thermal Wheel Unit. p Models shown: Horizontal & Vertical Plate Heat

    Exchanger Units.

    CLASSIFICATION & 4

    REGULATIONS

    BPS Classification 4

    Building Regulations 5

    Part L2A & Section 6

    BPS FEATURES & BENEFITS 6

    BPS External Features & 6

    Benefits

    BPS Internal Features & 8

    Benefits

    BPS HORIZONTAL UNITS 12

    TECHNICAL DATA

    BPS Unit 05 12

    BPS Unit 10 16

    BPS Unit 15 20

    BPS Unit 20 24

    BPS HORIZONTAL UNITS 28

    HANDINGS & AIRFLOW

    BPS HORIZONTAL UNITS

    ANCILLARIES 30

    BPS VERTICAL UNITS

    TECHNICAL DATA 38

    BPS Unit 07 38

    BPS Unit 12 42

    BPS Unit 17 46

    BPS Unit 22 50

    BPS Unit 32 54

    BPS Unit 42 58

    BPS VERTICAL UNITS 62

    HANDINGS & AIRFLOW

    BPS VERTICAL UNITS 64

    ANCILLARIES

    BPS WITH MITSUBISHI 72

    CONDENSING UNIT

    BPS CONSULTANT 74

    SPECIFICATION

    BPS Units Specification 74

    Ecosmart Control Platform 75

    Specification

    ECOSMART CONTROL 76

    Ecosmart Control Platform 76

    Overview

    Features of Controls 78

    Sensors and Enablers 80

    DUTY FOR HORIZONTAL & VERTICAL UNITS

  • 029 2085 82004

    BPS BOXER PACKAGED SOLUTIONS - CLASSIFICATION FEATURES

    L1 CASING AIR LEAKAGE CLASS [L]

    Ourconstructionhaspassedpositiveandnegativepressuretests,

    confirmingL1classification.L1meansthattheunitshallnotleakmore

    than0.22l/sperm2ofouterfaceareaofpositivepressuresectionand

    0.15l/sperm2ofouterfaceareaofnegativepressuresection,under

    testconditions. BPS has a classification of L1.

    CASING AIR LEAKAGE @ -400 Pa Class Max leakage rate (f700) (Ixs

    -1xm-2) Filter Class (EN 779)

    L3 1.32 G1toF7

    L2 0.44 F8toF9

    L1 0.15 SuperiortoF9

    EN 1886 - Casing Air Leakage Classifications at Negative Pressure

    CASING AIR LEAKAGE @ +700 Pa Class Max leakage rate (f400) (Ixs

    -1xm-2) Filter Class (EN 779)

    L3 1.9 G1toF7

    L2 0.63 F8toF9

    L1 0.22 SuperiortoF9

    EN 1886 - Casing Air Leakage Classifications at Negative Pressure

    TB1 THERMAL BRIDGING OF CASING CLASS [TB]

    Ahighthermalbridgingfactorisachievedbyseparationofthe

    conductivemetallicinternalandexternalsurfaces,withaninsulating

    material.Thiswillprovideaunitwiththelowestcondensation

    forming potentialandminimisethedamage/hazardsthismaycause.

    BPS has a classification of TB1.

    THERMAL BRIDGING FACTOR Class Thermal Bridging Factor (kb)

    TB1 0.75