30
RESIDENTIAL INDEX RESIDENTIAL Air cooling and water heating Cooling with heat recovery.......................................................................................158 Water cooling Homes and offices ..........................................................................................................159 Dehumidifiers Laundry dryers ..................................................................................................................160 Wall mounted ....................................................................................................................161 Wall mounted/floor standing ..................................................................................165 Residential ventilation Selection guide .................................................................................................................166 Ceiling mounted with heat recovery ..................................................................167 HCC2 accessories.............................................................................................................168 Cupboard and wall mounted with heat recovery ......................................171 Attic mounted with heat recovery .......................................................................176 HCV/HCH accessories ...................................................................................................178 Residential ventilation controllers Controllers............................................................................................................................185 TO DRY TO COOL TO VENTILATE 157 TO CONTROL PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 [email protected] www.polyair.ch

Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 [email protected] ... Fully hermetic rotary compressor

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

R E S I D E N T I A L

I N D E X

R E S I D E N T I A L

Air cooling and water heating

Cooling with heat recovery .......................................................................................158

Water cooling

Homes and offices ..........................................................................................................159

Dehumidifiers

Laundry dryers ..................................................................................................................160

Wall mounted ....................................................................................................................161

Wall mounted/floor standing ..................................................................................165

Residential ventilation

Selection guide .................................................................................................................166

Ceiling mounted with heat recovery ..................................................................167

HCC2 accessories .............................................................................................................168

Cupboard and wall mounted with heat recovery ......................................171

Attic mounted with heat recovery .......................................................................176

HCV/HCH accessories ...................................................................................................178

Residential ventilation controllers

Controllers ............................................................................................................................185

TO DRY

TO COOL

TO VENTILATE

157

TO CONTROL

PolyAir Engineering Sàrl Champ Cheval 2CH - 1530 Payerne

+41 26 520 75 [email protected] www.polyair.ch

Page 2: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

158

A I R CO O L I N G A N D WAT E R H E AT I N G

CO O L I N G W I T H H E AT R E CO V E R Y

Features

�Cooling down to 7°C (-5°C with hot gas defrost option)

�Rugged PVC coated galvanised steel case

�Wall mounted

�Easy to install and connect

�AW 450SC produces up to 3300 litres of hot water per day at 50°C – enough for 660 typical covers per day

�AW 250SC produces up to 2400 litres of hot water per day at 50°C – enough for 430 typical covers per day

Applications

�Home hot water heating

�Beer and wine cellars

�Waste heat recovery from boiler rooms with water pre-heat capacity

�Launderettes

�Spas and clubs

�Campsites and caravan parks

AW 450 S C

Options

�Hot gas defrost

�Stainless steel case

�High temperature version for heating water to 65°C

�Heat reject unit (required when air cooling has priority over water heating)

�Air filter

Specifications Units AW 250SC AW 450SC

Air temperature rangeWater temperature rangeMax. water flowMin. water flowMax. water resistanceMin. water resistanceWater connections

°C°C

l/minl/minmhdmhd

7*-3610-50

14123.52.8

22mm pipe stub

7*-3610-50

22184.83.5

22mm pipe stubAir flowExternal resistanceFan driveSound level @ 3m

m3/hmmWG

dB(A)

10190

Direct57

16980

Direct59

Power supplySupplyLRAFLAPower consumedProduct size (h x w x d)Weight

V/HzAAA

kWmmkg

220-240/1ph/5013135.50.9

665 x 780 x 34060

220-240/1ph/502020111.8

665 x 1245 x 34095

* -5 with hot gas defrost

Page 3: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

159

TO

CO

OL

WAT E R CO O L I N G

H O M E S A N D O F F I C E S

Features

�Domestic sizes giving up to 900 litres per hour of cold water production

�Fully packaged, robust and weatherproof construction

�Quiet operation

�Purpose-built for operation in the Gulf region

�Certified cupronickel WRAS* approved heat exchanger to withstand pool chemicals and allow the unit to be used in a direct system

�Non ozone depleting refrigerant (R134A)

* WRAS is a conformance mark that demonstrates that an item complies to strict standards set out by UK water regulations. This standard gives you peace of mind that approved products will not contaminate your water supply and are safe to use within their stated pressure and temperature ranges.

WA 1234 B C

Applications

�Homes and villas

�Plunge pools

Options

�Available in 60Hz

Specifications Units WA 634ACL WA 634ACH WA 1234BC

Air temperature rangeWater temperature range

Output @ 32°C waterInput @ 32°C water

Output @ 10°C waterInput @ 10°C water

°C°C

kWkW

kWkW

0-5510-40

5.51.9

2.81.4

10-5510-40

5.51.9

2.81.4

10-5510-40

9.83.2

5.92.5

Nominal cold water productionMin./max. tank size

l/hl

50060/500

50060/500

900110/1000

Electrical inputPower supplyMax. supply fuseStarting current

kWV/Hz

AA

1.9220-240/1ph/50

1332

1.9220-240/1ph/50

1332

3.2400/3ph/50

1648

Water flowFlow resistanceConnections

l/min ±10%mhdinch

332.1

¾ BSPM

332.1

¾ BSPM

332.1

¾ BSPMNominal air flowFan external resistance (standard)

m³/hPa

150050

150050

300050

Fan typeSound pressure level @ 3mProduct size (w x d x h)Weight

dB(A)mmkg

1 x Centrifugal63

820 x 702 x 762111

1 x Centrifugal63

820 x 702 x 762111

1 x Centrifugal65

1060 x 705 x 807157

* Cooling output and input calculated at +45°C/50% RH ambient air

Page 4: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

160

D E H U M I D I F I E R S

L AU N D RY D RY E R S

Features

�Case made of galvanized steel, hood made of easy to clean plastic, service-friendly housing construction

�Space-saving wall mounting

�Blue-Dry®-Technology for particularly energy-saving operation – even at low humidities and temperatures

�Fully hermetic rotary compressor

�Energy-efficient EC-radial fan

�Maintenance-friendly refrigerant circuit with service connector

�Condenser and evaporator made of copper tubes with aluminium fins

�On-demand hot gas defrost system for optimum operation in a cool places

W T 230W T 240W T 250W T 280

Applications

� Laundry drying

� Basements and cellars

� Living rooms

� Warehouses

� Preservation

� Sewage treatment, waterworks

Specifications Units WT 230 WT 240 WT 250 WT 280

Capacity (30°C/80% RH) l/24h 35.5 36.5 57.1 79.2Air flow m3/h 750 830 870 920Energy consumption per kg laundry kWh/kg 0.25 0.25 0.27 0.30Drying time h/min 4/55 5/35 5/23 5/13Operating temperature range °C 3-32 3-32 3-32 3-32Operating humidity range % 35-95 35-95 35-95 35-95Power supply V/Hz 230/1ph/50 230/1ph/50 230/1ph/50 230/1ph/50Sound level dB(A) 61 61 60 60Condensate drain mm 15 x 2 15 x 2 15 x 2 15 x 2Product size (h x w x d) mm 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345 809 x 640 x 345Weight kg 40 40 42 43

Easy to use electronic eDRY®

(Languages: DE/IT/FR/E)

�Operation mode (space drying/laundry drying)

�Display actual humidity

�Setting target humidity

�Program selection (Timer, Turbo-drying)

�Drying Automatic

Page 5: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

161

TO

DR

Y

D E H U M I D I F I E R S

WA L L M O U N T E D

C D F 10Features

�Built into a strong and robust powder coated hot galvanized sheet metal cabinet

�Evaporator and condenser coils are epoxy-coated for high corrosion resistance

�The condensate outlet is located at the bottom of the CDF dehumidifier. The outlet stub can be connected to a water hose.

�Easy accessible washable air filters from front cover

�Reciprocating compressor

�Axial fan

�Electronic control and user-friendly display panel

�Active, demand-controlled defrosting

�Available in white and grey

Applications

� Basements and cellars

� Garages and car storage

� Archives and museums

� Churches

� Changing rooms

Optional accessories

�Room hygrostat

�Water tank, grey or white

C D F 10 with water tank

Specifications Units CDF 10

Operating temperature rangeOperating humidity rangeDehumidification @ 30°C/60% RHAir flowPower supplyMax. power consumptionSound pressure level @ 1mRefrigerantWater container capacityProduct size (h x w x d)Weight

°C% RHl/24hm3/hV/HzkW

dB(A)

lmmkg

3-3040-100

7.5220

230/1ph/500.346

R134a5.5

600 x 535 x 24028

Page 6: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

162

D E H U M I D I F I E R S

WA L L M O U N T E D

D H 15Features

�Compact design for installation in small areas

�Self contained with fully automatic operation

�Integral humidistat

�Tamper proof controls

�Epoxy polyester painted zintec steel cabinet

�Hot gas defrost for low temperature operation

�Air filter

Applications

� Basements and cellars

� Stairwells

� Garages and car storage

� Libraries

� Drying rooms

� Store rooms

� Unheated premises

Options

�Through the wall version

Specifications Units DH 15AX

Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyNominal power consumptionFLAMaximum supply fuseLRA (compressor start)Product size (w x d x h)WeightCondensate drain size (flexible plastic hose)

°Cl/24hkW

m3/hPa

dB(A)

V/HzkWAAA

mmkg

mm ID

0-35150.9225

053

R407c230/1ph/50

0.433.81018

825 x 363 x 3203310

Page 7: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

163

TO

DR

Y

D E H U M I D I F I E R S

WA L L M O U N T E D

D H 30

Specifications Units DH 30AX DH 30AXP

Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)

°Cl/24hkW

m3/hPa

dB(A)

V/HzkWAAA

kWl/minmmkg

mm ID

0-35301.9700

052

R407c230/1ph/50

0.754.410

15.8Optional LPHW

3.05.0

782 x 270 x 6484016

0-35301.9700

052

R407c230/1ph/50

0.7512.720

15.8Standard Electric

2.0-

782 x 270 x 6484016

Features

�Self contained with fully automatic operation

�Integral humidistat

�Polyester coated evaporator and condenser

�Plastisol coated galvanised steel cabinet

�Hot gas defrost for low temperature operation

�Quiet centrifugal fans

�Remote humidistat and on/off function

Applications

� Drying rooms

� Modular buildings

� Electrical sub-stations

� Sports clubs and changing rooms

� Warehousing and storage

� Museums, libraries and galleries

� Garages

Options

�Through the wall version

�Electric air heater

�LPHW air heater

�Floor stand kit

Page 8: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

164

D E H U M I D I F I E R S

WA L L M O U N T E D

D H 60

Specifications Units DH 60AX DH 60AXP

Operating temperature rangeDehumidification @ 30°C/60% RHHeat recovered to air @ 30°C/60% RHAir flowExternal static pressureSound pressure level @ 3mRefrigerantPower supplyDehumidifier power inputFLAMaximum supply fuseLRA (compressor start)Heater typeHeat outputFlow rateProduct size (w x d x h)WeightCondensate drain size (flexible plastic hose)

°Cl/24hkW

m3/hPa

dB(A)

V/HzkWAAA

kWl/minmmkg

mm ID

0-35603.5

12800

54R407c

230/1ph/501.27.51330

Optional LPHW5.05.0

1247 x 270 x 6486016

0-35603.5

12800

54R407c

230/1ph/501.2

24.23230

Standard Electric4.0-

1247 x 270 x 6486016

Features

�Self contained with fully automatic operation

�Integral humidistat

�Polyester coated evaporator and condenser

�Plastisol coated galvanised steel cabinet

�Hot gas defrost for low temperature operation

�Quiet centrifugal fans

�Remote humidistat and on/off function

Options

�Through the wall version

�Electric air heater

�LPHW air heater

�Floor stand kit

Applications

� Archives and museums

� Churches

� Changing rooms

� Waterworks

� Garages and car storage

Page 9: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

165

TO

DR

Y

C D F 50

D E H U M I D I F I E R S

WA L L M O U N T E D / F LO O R S TA N D I N G

Features

�Built into a strong and robust powder coated hot galvanized sheet metal cabinet

�Evaporator and condenser coils are epoxy-coated for high corrosion resistance

�Fixed to the wall by means of a wall mounting strip supplied with the unit

�Condensate outlet located at the bottom. Outlet stub can be connected to a ¾" hose

�Outside connection to mains

Controls

�Built in electronic hygrostat and thermostat

�Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories)

�0-VOLT connection for alarm

�230 V for control valve, exhaust fan and pump/boiler

�RS 485 gate for BMS (Modbus)

Applications

� Archives and museums

� Churches

� Changing rooms

� Waterworks

� Garages and car storage

Optional accessories

�Wireless remote control DRC1

�Floor mounting kit

�Water heating coils

�Control valve for water heating coils

�Electric heating coils

�Exhaust fans

Diodes

BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors

Defrosting

Active, demand-controlled defrosting is incorporated in the electronic control.

Service

For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.

Specifications Units CDF 40 CDF 50 CDF 70

Operating temperature rangeOperating humidity rangeDehumidification @ 30°C/60% RHAir flowPower supplyMax. power consumptionSound pressure level @ 1mRefrigerantFilterProduct size (w x d x h)WeightCondensate drain size (stub)

°C% RHl/24hm3/hV/HzkW

dB(A)

mmkg

inch

3-3240-100

30400

230/1ph/500.7846

R407cG3 PPI 15

1010 x 327.8 x 699.956.5

¾

3-3240-100

53680

230/1ph/501.3747

R407cG3 PPI 15

1060 x 327.8 x 699.965¾

3-3240-100

55900

230/1ph/501.550

R407cG3 PPI 15

1495 x 327.8 x 699.975.5

¾

Page 10: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

166

R E S I D E N T I A L V E N T I L AT I O N

S E L E C T I O N G U I D E

Model HCC 2 PLA HCV 300 HCV 500 HCV 700 HCV 4/HCV 5 HCH 5 HCH 8

Installation Wall/ceiling void Wall Wall Wall Cupboard/wall Attic Attic

Energy class A (A+ can be obtained with optional accessory kit)

Max air flow (m3/h) 260 280/400/550 280/400/550 280/400/550 275/375 375 530

Max. floor area (m2) 110 150 260 450 200/260 280 350

WxHxD (mm) 600 x 279 x 1122 600 x 1000 x 430 700 x 1050 x 603 700 x 1050 x 750530x1005x434/ 590x1055x584

580x600x1180 780x600x1180

Weight (kg) 34 36.5 49.5 64 32/45 52 70

Duct connection (mm) ø125 ø125 ø160 ø200 ø125/ ø160 ø160 ø250

Heat exchanger Plastic Alu Alu Alu Alu Alu Alu

G4 filter F7 pollen filter + + + + + + +PHI certificate ÷ ÷ ÷ ÷/ SAP Appendix Q listed ÷ ÷ ÷ ÷ ÷/ Demand control + Automatic bypass cooling Manual/

Integrated software bypass ÷ ÷ ÷Frost protection of heat exchanger

Week programs + + +Night mode + + + + + + +Holiday mode + + + + + + +Fireplace mode + + + + Filter alarm Connection of fire/smoke alarm system + + +Connection to geothermal collector + + + + + + +BMS connection KNX connection ÷ ÷ ÷Right/left hand switching ÷ ÷ ÷Wireless remote control + + + + + + +Wired control panel + + + + ÷ Heating coils + + + + + + +PC tool + + + + ÷ ÷ ÷RH sensor + VOC sensor + + + + ÷ ÷ ÷CO2 sensor + + + + + + +

included + optional ÷ not available

Performance Functionalities Accessories

*Depending on local legislation

Page 11: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

167

TO

VE

NT

ILA

TE

H CC 2 P L A

R E S I D E N T I A L V E N T I L AT I O N

C E I L I N G M O U N T E D W I T H H E AT R E CO V E RY

Features

� High efficiency heat recovery – up to 94%

� EC fan motors with low energy consumption (low SPI)

� Only 300mm installation headroom height is required

� Time controlled ventilation level, based on 11 different built in pre-programmed week programs. This reduces power consumption in periods with low ventilation demands.

� Summer cooling mode

� Fireplace mode, creating a momentary inside overpressure, to enhance chimney functionality

� Easy-to-install and commissioning solution with built in air measure ports, for easy balancing with PC-Tool

� Electronically left/right fan direction switching, allowing same unit type to adapt any physical installation requirements, regardless of ceiling and wall selection.

� TCP/IP ModBus connection, for inter-operation with Building Management System

Applications

� Private houses

� Villas

� Apartments

Specifications Units HCC 2

Max. air flow (max. @ 100 Pa) m3/h 260Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A+1

Operating range DIBt m3/h 70 to 140Operating range Passivhaus m3/h 70 to 140Efficiency DIBt % 93.8Efficiency Passivhaus % 93Installation surrounding temperature °C +12 - +40Maximum humidity in extract air @ 25°C RH% 65Outdoor temperature (without preheating installed) °C -12 2 - +50Outdoor temperature (with preheating installed) °C -25 - +50CabinetProduct size (w x h x d without bracket) mm 600 x 279 x 1122Duct connections ø mm 125 - femaleWeight kg 34Fire classification of the unit EN 13501 class EDrainage hose included ø/length 1/2" – 2mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 127

1 Requires an optional Energy Efficiency Class A+ kit (including VOC sensor and RH% sensor). Described under 'Accessories'.2 Preheating is recommended when outside temperatures are below -5°C to ensure balanced operation of the home ventilation unit.

Page 12: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

168

R E S I D E N T I A L V E N T I L AT I O N

H CC 2 ACC E S S O R I E S

Wireless remote control

Wired control

Wired control (HCP 10)

Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.

The HCP 10 wired control gives the user the following options:

� Manual control of air change (step 0-4)

� Control of air change with week program

� Demand controlled air change (if RH and VOC sensors are connected)

� Enable summer mode (only extract air)

� Enable manual bypass (requires an optional mechanical bypass to be mounted)

� Enable fireplace mode

� Reading and resetting of alarms, including filter alarm

The wired HCP 10 control offers the installer the possibility of adjusting the air volumes during commissioning without using Dantherm’s PC Tool.

Wireless remote control (HRC 3)

Dantherm offers a wireless remote control, which can be mounted on the wall or placed on a shelf. The remote control is designed for the user, but also includes a special installer menu, allowing the installer to do extensive settings, without the use of the PC Tool.

The remote control has an acoustic alarm that will sound when the filters need to be inspected or replaced. This insures correct maintenance even when the HCC 2 unit is set to demand mode, and regular attention is not towards the remote control.

The user features are:

� Fan speed in manual mode.

� Select demand mode (requires RH and/or VOC sensors to be mounted).

� Select week mode and week program 1-11.

� Manually activated bypass. It closes again automatically.

� Enable fireplace boost mode. Seven minutes with overpressure inside the house for easy ignition of a fireplace.

� Enable away mode in which the unit decreases permanently to speed 1.

� Enable night mode in which the unit decreases to speed 1. The time night mode can be adjusted.

� Remaining filter period + adjustment of same.

� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).

� Setting time and date.

Page 13: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

169

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

H CC 2 ACC E S S O R I E S

External electrical preheating coil, 900 WThe electrical heating coil prevents ice building up in the heat exchanger at low temperatures. The heating coil is mounted in the outdoor air duct. The heating coil is connected to and controlled by the HCC 2 controller, which adjusts the heat output so as to ensure an ice-free heat exchanger with the lowest possible energy consumption.

Pre-heat insulation kit for HCC 2This insulation kit is designed for fixing to the HCC 2 preheater. This customized insulation kit protects against thermal bridges, condensation and excessive energy consumption.

Mechanic bypass moduleThe HCC 2 home ventilation unit can be fitted with an automatically controlled bypass damper module, that exploits the colder outdoor air to cool down the home, e.g. after a hot summer’s day, when the outdoor night time temperature falls below the temperature of the house. The bypass module leads all the hot exhaust air past the heat exchanger in order to achieve the best possible cooling effect.

RH% demand sensor (also included in the Energy Efficiency Class A+ kit)The HCC 2 home ventilation unit can be fitted with a humidity sensor (RH%). This sensor will continuously monitor the humidity of the extract air and adjust the air flow level accordingly. This operation is named demand mode. If a wireless remote control is connected, the level will be shown in the display using a 3 level icon.

Using demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If both VOC and RH% sensors are fitted, the ventilation level is set by the highest demand from just any one of the sensors.

VOC air quality demand sensor (also included in the Energy Efficiency Class A+ kit)The HCC 2 unit can be fitted with a VOC air quality sensor. This sensor will continuously monitor the level of artificial as well as natural organic fumes in the air. Examples of included fumes:

� Natural fumes, e.g. formaldehyde from building materials

� Chemical fumes from sprays, e.g. hair spray or perfumes

� Indoor pollution e.g. from smoking and printing with laser printer

� Fumes from fire retardant substances in carpets, paint and furniture

Using the VOC sensor in demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If a wireless remote control is connected, the actual VOC level will be shown in the display using a 3 level icon.

Digital plug (bag with 25 pcs.)

This digital plug is connected to the control of the HCC 2 unit. This allows to override the following:

� Fan speed 0, 1, 2, 3, 4

� Fire/smoke/negative pressure /stop + alarm

� High water level stop + alarm

RH% demand sensor

Mechanic bypass module

Pre-heat insulation kit

VOC air quality demand sensor

Digital plug

External electrical preheating coil

Page 14: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

170

R E S I D E N T I A L V E N T I L AT I O N

H CC 2 ACC E S S O R I E S

Condensate pump kit

This condensate pump kit is designed for mounting on HCC 2 units where there is no safe drain with fall to a drainage or on units where the drain is too far away (more than 5m horizontal way). The kit is furnished with a bracket for fixing it to the HCC 2 unit, a power supply cable for connection to the HCC 2 unit, pressure equalization hose and drain hose.

Hygrostat, Sauter HSC 120 F001

The hygrostat is connected to the accessory control in case that a higher air change rate is required in rooms with high humidity.

Accessory control HAC 2

One or more of the following functions can be connected to the accessory control:

� After heating coils for water or electricity

� Geothermal preheating/precooling coils

� 24 VDC duct damper outlet

� Stop function inlet

� Fire/smoke detector inlet

� External CO2 sensor for demand control

� External hygrostat

� Filter alarm outlet

� General alarm

HAC 2 comes with 3m cable

Power supply 230VAC – 24VDC, for duct control

Power supply to be mounted in the accessory control if the ventilation unit controls a duct damper.

CO2 sensor

The CO2 sensor is connected to the accessory control if the air change has to be controlled in accordance with the CO2 level in a given room.

USB cable, 3m

USB cable to be used in connection with software update of HCC 2 and Dantherm PC Tool (HPT 1).

Calibration set (bag with 10 sets)

This calibration kit contains 10 sets with each 3m hose, two suction cups with hook and two nipples. The kit is used during commissioning for adjusting the HCC 2 air flows.

Dantherm PC Tool Kit (HPT 1)

The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).

Accessory control HAC 2

Power supply 230VAC - 24VDC

Co2 sensor

PC Tool Kit

USB cable, 3m

Condensate pump kit

Hygrostat, Sauter HSC 120 F001

Calibration set

Page 15: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

171

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY

Features

� Demand-controlled ventilation with integrated humidity sensor� This reduces power consumption at times with low ventilation

demands� Summer mode, in which supply fan is stopped, and any open

window will supply cooler outside air, lowering the room temperature

� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality

� High efficiency heat recovery� EC fan motors with extremely low energy consumption (low SPI)� Easy-to-install and commission solution with built -in air pressure

spigots for easy calibration� Highly customizable units, by adding a high variety of internal

as well as external accessories. See more in the 'Accessories' section.

� HCV 300 models takes up only as little space as a 60x60cm cupboard

Applications

� Private houses

� Villas

� Apartments

H C V 300

Specifications Units HCV 300

Max. air flow (max. @ 100 Pa) m3/h 275

Bypass Yes, automatic

PerformanceEnergy consumption class (SEC-class), average climate A

Energy consumption class (SEC-class), average climate A+1

Efficiency EN13141-7 dry (hSUP) % 86

Installation surrounding temperature °C 12 - 50

Outdoor temperature without preheater installed (tODA) °C -12 - +50

Outdoor temperature with preheater installed °C -25 - +50

CabinetProduct size (w x h x d without bracket) mm 600 x 1000 x 430

Ducts Ø mm 125 - female

Weight kg 36.5

Fire classification of the unit EN 13501 class E

Drainage hose included (Ø/length) "/m ¾" - 1m

ElectricalPower supply V/Hz 230/1ph/50

Max. power consumption (without heater options fitted) W 170

Page 16: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

172

R E S I D E N T I A L V E N T I L AT I O N

C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY

Features

� Demand-controlled ventilation with integrated humidity sensor

� This reduces power consumption at times with low ventilation demands

� Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature

� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality

� High efficiency heat recovery

� EC fan motors with extremely low energy consumption (low SPI)

� Easy-to-install and commission solution with built -in air pressure spigots for easy calibration

� Highly customizable units, by adding a high variety of internal as well as external accessories. See more in the 'Accessories' section.

Applications

� Private houses

� Villas

� Apartments

H C V 500

Specifications Units HCV 500

Max. air flow (max. @ 100 Pa) m3/h 375

Bypass Yes, automatic

PerformanceEnergy consumption class (SEC-class), average climate A

Energy consumption class (SEC-class), average climate A+1

Efficiency EN13141-7 dry (hSUP) % 86

Installation surrounding temperature °C 12 - 50

Outdoor temperature without preheater installed (tODA) °C -12 - +50

Outdoor temperature with preheater installed °C -25 - +50

CabinetProduct size (w x h x d without bracket) mm 700 x 1050 x 603

Ducts Ø mm 160 - female

Weight kg 49.5

Fire classification of the unit EN 13501 class E

Drainage hose included (Ø/length) "/m ¾" - 1m

ElectricalPower supply V/Hz 230/1ph/50

Max. power consumption (without heater options fitted) W 170

Page 17: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

173

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY

Features

� Demand-controlled ventilation with integrated humidity sensor

� This reduces power consumption at times with low ventilation demands

� Summer mode, in which supply fan is stopped, and any open window will supply cooler outside air, lowering the room temperature

� Fireplace mode, creating a temporary inside overpressure, to enhance chimney functionality

� High efficiency heat recovery

� EC fan motors with extremely low energy consumption (low SPI)

� Easy-to-install and commission solution with built -in air pressure spigots for easy calibration

� Highly customizable units, by adding a high variety of internal as well as external accessories. See more in the 'Accessories' section.

Applications

� Private houses

� Villas

H C V 700

Specifications Units HCV 700

Max. air flow (max. @ 100 Pa) m3/h 550

Bypass Yes, automatic

PerformanceEnergy consumption class (SEC-class), average climate A

Energy consumption class (SEC-class), average climate A+1

Efficiency EN13141-7 dry (hSUP) % 85

Installation surrounding temperature °C 12 - 50

Outdoor temperature without preheater installed (tODA) °C -12 - +50

Outdoor temperature with preheater installed °C -25 - +50

CabinetProduct size (w x h x d without bracket) mm 700 x 1050 x 750

Ducts Ø mm 200 - female

Weight kg 70

Fire classification of the unit EN 13501 class E

Drainage hose included (Ø/length) "/m ¾" - 1m

ElectricalPower supply V/Hz 230/1ph/50

Max. power consumption (without heater options fitted) W 234

Page 18: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

174

R E S I D E N T I A L V E N T I L AT I O N

C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY

H C V 4

Features

� Demand-controlled ventilation with integrated humidity sensor

� High efficiency heat recovery

� EC motors with extremely low energy consumption (low SPI)

� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit

� HCV models are suitable for installation in 60 x 60cm cupboards

� Integrated control panel HCP 4 in front

Applications

� Private houses

� Villas

� Apartments

Specifications Units HCV 4

Max. air flow (max. @ 100 Pa) m3/h 275Bypass Yes, manualPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1

Efficiency EN13141-7 dry (hSUP) % 89.5Surrounding temperature where the unit is installed °C 10-50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d standard mounting rail/rail for plan mounting) mm 1005 x 530 x 434/419Duct connection mm 125Weight kg 32Fire classification of the unit EN 13501 class EDrainage hose included (Ø/length) ¾" - 1mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 88

1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.

Page 19: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

175

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

C U P B O A R D A N D WA L L M O U N T E D W I T H H E AT R E CO V E RY

H C V 5

Features

� Demand-controlled ventilation with integrated humidity sensor

� High efficiency heat recovery

� EC motors with extremely low energy consumption (low SFP)

� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit

� HCV models are suitable for installation in 60 x 60cm cupboards

� Integrated control panel HCP 4 in front

Applications

� Private houses

� Villas

� Apartments

Specifications Units HCV 5

Max. air flow (max. @ 100 Pa) m3/h 375Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1

Efficiency EN13141-7 dry (hSUP) % 88Efficiency Passivhaus % 80Surrounding temperature where the unit is installed °C 10-50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 1055 x 590 x 584/569Duct connection mm 160Weight kg 32Fire classification of the unit EN 13501 class EDrainage hose included (Ø/length) ¾" - 1mElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 154

1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.

Page 20: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

176

H C H 5

R E S I D E N T I A L V E N T I L AT I O N

AT T I C M O U N T E D W I T H H E AT R E CO V E R Y

Features

� Demand-controlled ventilation with integrated humidity sensor

� High efficiency heat recovery

� EC motors with extremely low energy consumption (low SPI)

� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit

� HCH models are suitable for installation on uninsulated attics

� Separate HCP 4 control panel included + 2m cable

Applications

� Private houses

� Villas

� Apartments

Specifications Units HCH 5

Max. air flow (max. @ 100 Pa) m3/h 375Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1

Efficiency EN13141-7 dry (hSUP) % 88Efficiency Passivhaus % 81Surrounding temperature where the unit is installed °C -20 - +50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 x 580Duct connection mm 160Weight kg 52Fire classification of the unit EN 13501 class EElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 154

1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.

Page 21: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

177

TO

VE

NT

ILA

TE

H C H 8

R E S I D E N T I A L V E N T I L AT I O N

AT T I C M O U N T E D W I T H H E AT R E CO V E R Y

� Demand-controlled ventilation with integrated humidity sensor

� High efficiency heat recovery

� EC motors with extremely low energy consumption (low SPI)

� Easy-to-install solution with pressure pipes for air volume measurement and adjustment on the unit

� HCH models are suitable for installation on uninsulated attics

� Separate HCP 4 control panel included + 2m cable

Applications

� Private houses

� Villas

� Apartments

Specifications Units HCH 8

Max. air flow (max. @ 100 Pa) m3/h 530Bypass Yes, automaticPerformanceEnergy consumption class (SEC-class), average climate AEnergy consumption class (SEC-class), average climate A1

Efficiency EN13141-7 dry (hSUP) % 86Efficiency Passivhaus % 83Surrounding temperature where the unit is installed °C -20 - +50Operational temperature range without pre-heating °C -132 - +50Operational temperature range with pre-heating °C -30 - +50CabinetProduct size (h x w x d(standard mounting rail/rail for plan mounting) mm 600 x 1180 780Duct connection mm 250Weight kg 70Fire classification of the unit EN 13501 class EElectricalPower supply V/Hz 230/1ph/50Max. power consumption (without heater options fitted) W 246

1 Requires an Energy Efficiency Class A+ kit (including CO2 sensor and HAC 1 accessory control). Described under Accessories. 2 We recommend preheating at temperatures under -6°C to ensure a balanced operation.

Page 22: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

178

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Wireless remote control

Dantherm offers an LCD based wireless remote control, designed either to be mounted on the wall, or to be placed standing on a table or cabinet. This remote control is designed for the user, but also includes a special installer menu, where it is possible for the installer to do extensive settings, without the use of the PC-tool.

The user features are:

� Fan speed in manual mode.

� Select demand mode.

� Select week mode and week program 1-11.

� Manually open bypass for 6 hours. Will close automatically.

� Enable fireplace boost mode. Four minutes with overpressure inside the house, for easy ignition of a fireplace.

� Enable/disable away mode, in which the unit decreases permanently to speed 1. Auto off after four weeks.

� Enable/disable night mode, in which the unit increases to fan speed 1. The hour for enable/disable can be adjusted with appropriate control accessory.

� Filter timer reset

� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).

� Setting time and date.

The remote control has an acoustic alarm, that will sound when filter needs to be inspected or replaced. This insures correct maintenance even when the HCC 2 is set to demand mode, and regular attention is not towards the remote control. The wireless remote control uses two AAA alkaline batteries. Battery lifetime up to two years is possible, as the display and remote goes into hibernation mode after two minutes without user interaction.

Wireless remote control

Display with iconsRead actual temperatures, relative humidity,

CO2 level, operation and filter status and alarms, if any

Acoustic alarm

2 menu levelsUser menu

Installer menu

5-way navigation buttonSelection of operation and

control.Adjustment of setpoints

Page 23: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

179

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Wired control

Wired control (HCP 10)

Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.

The HCP 10 wired control gives the user the following options:

� Manual control of air change (step 0-4)

� Control of air change with week program

� Demand controlled air change (if RH and VOC sensors are connected)

� Enable summer mode (only extract air)

� Enable manual bypass (requires an optional mechanical bypass to be mounted)

� Enable fireplace mode

� Reading and resetting of alarms, including filter alarm

The wired HCP 10 control offers the possibility of adjusting the air volumes without using Dantherm’s PC Tool.

Hygrostat, Sauter HSC 120 F001

The hygrostat is connected to the accessory control in case that a higher air change rate is required in rooms with high humidity.

Power supply 230VAC – 24VDC, for duct control

Power supply to be mounted in the accessory control if the ventilation unit controls a duct damper.

CO2 sensor

The CO2 sensor is connected to the accessory control if the air change has to be controlled in accordance with the CO2 level in a given room.

USB cable, 3m

USB cable to be used in connection with software update of HCC 2 and Dantherm PC Tool (HPT 1).

Dantherm PC Tool Kit (HPT 1)

The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).

Power supply 230VAC - 24VDC

CO2 sensor

Hygrostat, Sauter HSC 120 F001

PC Tool Kit

USB cable, 3m

Page 24: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

180

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

RH% demand sensor (also included in the Energy Efficiency Class A+ kit)

The HCC 2 home ventilation unit can be fitted with a humidity sensor (RH%). This sensor will continuously monitor the humidity of the extract air and adjust the air flow level accordingly. This operation is named demand mode. If a wireless remote control is connected, the level will be shown in the display using a 3 level icon.

Using demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If both VOC and RH% sensors are fitted, the ventilation level is set by the highest demand from just any one of the sensors.

VOC air quality demand sensor (also included in the Energy Efficiency Class A+ kit)

The HCC 2 unit can be fitted with a VOC air quality sensor. This sensor will continuously monitor the level of artificial as well as natural organic fumes in the air. Examples of included fumes:

� Natural fumes, e.g. formaldehyde from building materials

� Chemical fumes from sprays, e.g. hair spray or perfumes

� Indoor pollution e.g. from smoking and printing with laser printer

� Fumes from fire retardant substances in carpets, paint and furniture

Using the VOC sensor in demand mode will result in the correct level of ventilation with lowest possible electrical power consumption. If a wireless remote control is connected, the actual VOC level will be shown in the display using a 3 level icon.

Accessory control HAC 2

One or more of the following functions can be connected to the accessory control:

� After heating coils for water or electricity

� Geothermal preheating/precooling coils

� 24 VDC duct damper outlet

� Stop function inlet

� Fire/smoke detector inlet

� External CO2 sensor for demand control

� External hygrostat

� Filter alarm outlet

� General alarm

� HAC 2 comes with 3m cable

RH% demand sensor

VOC air quality demand sensor

Accessory control HAC 2

Page 25: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

181

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Electric duct heaters

The electric heating coils are designed for installation in the supply or extract air duct. The heating coil is provided with duct connections with a rubber sealing gasket. The heating coil is not suitable for outdoor installation. The control current is connected to the accessory control HAC 1. Connection to supply voltage 230V is made separately.

Electric pre-/after heating coil, 0-10V controlled by the accessory control

The heating coil is controlled by a stepless regulation via the accessory control HAC 1.

Electric pre-/after heating coil, direct control by the built-in thermostat

The heating coil is controlled by the built-in thermostat. Both heating coils are

supplied with a duct sensor. Both heating coils are supplied with a duct sensor.

Capacity, dimensions and weight

The electric heating elements inside a coil are un-finned and therefore the resulting air pressure loss is negligible.

Specifications Units HCV 4 HCV 5 HCH 5 HCH 8

Air volume m3/h 220 300 300 450Heat output kW 0.9 1.2 1.2 1.8Temperature rise °C 13.7 14.2 14.2 13.4Power consumption 1x230V A 4.1 5.5 5.5 8.2Duct connection Ø mm 125 160 160 250Weight kg 3.0 3.5 3.5 5.0

375

AIR

278

42 42 82Ø

Ø+17

Electric pre-/afterheating coil 0-10V

Electric pre-/afterheating coil,direct control

Page 26: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

182

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Water heating coils

The water heating coil kit includes 2RR, 2-way water valve, 0-10V servo motor, 230/24VAC trafo, duct sensor and tube sensor for frost protection. It is controlled by the accessory control HAC 1.

Water heating coil

Servo motor

2-way water valve

230/24 V AC trafo

*Air in 15°C

HCV 4(CWW 125-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215

Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5

HCV 5/HCH 5(CWW 160-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 145 250 355 145 250 355 145 250 355 145 250 355

Air temp. out* °C 47 43 40 33 31 29 21 21 21 21 21 21Pressure loss Pa 6 15 27 6 15 27 6 15 27 6 15 27Capacity kW 1.6 2.4 3.0 0.9 1.3 1.7 0.3 0.5 0.7 0.3 0.5 0.7Water flow l/h 72 108 144 36 72 72 14 24 35 12 28 30Pressure loss, max. KPa 1.0 3.0 4.0 0.5 1.0 2.0 0.2 0.4 0.5 0.1 0.4 0.5

HCH 8(CWW 250-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 360 630 360 630 360 630 360 630

Air temp. out* °C 44 40 31 29 21 21 21 21Pressure loss Pa 10 25 10 25 10 25 10 25Capacity kW 3.6 5.3 2.0 3.0 0.74 1.29 0.74 1.28Water flow l/h 144 252 108 144 30 61 40 61Pressure loss, max. KPa 1.0 3.0 1.0 2.0 0.5 1.0 0.7 1.0

HCV 300(CWW 125-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215

Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1.0 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5

Page 27: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

183

TO

VE

NT

ILA

TE

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Water heating coils

The water heating coil kit includes 2RR, 2-way water valve, 0-10V servo motor, 230/24VAC trafo, duct sensor and tube sensor for frost protection. It is controlled by the accessory control HAC 2.

HCV 300(CWW 125-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 85 150 215 85 150 215 85 150 215 85 150 215

Air temp. out* °C 40 36 34 28 25 23 21 21 21 21 21 21Pressure loss Pa 11 28 51 11 28 51 11 28 51 11 28 51Capacity kW 0.7 1.1 1.4 0.4 0.5 0.6 0.2 0.3 0.5 0.2 0.3 0.5Water flow l/h 36 36 72 36 36 36 9 10 23 17 22 28Pressure loss, max. KPa 0.5 0.5 1 0.5 0.5 0.5 0.2 0.2 0.4 0.3 0.4 0.5

HCV 500/HCV 700** (CWW 160-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 145 250 355 145 250 355 145 250 355 145 250 355

Air temp. out* °C 47 43 40 33 31 29 21 21 21 21 21 21Pressure loss Pa 6 15 27 6 15 27 6 15 27 6 15 27Capacity kW 1.6 2.4 3.0 0.9 1.3 1.7 0.3 0.5 0.7 0.3 0.5 0.7Water flow l/h 72 108 144 36 72 72 14 24 35 12 28 30Pressure loss, max. KPa 1.0 3.0 4.0 0.5 1.0 2.0 0.2 0.4 0.5 0.1 0.4 0.5

HCV 700**(CWW 250-2-2.5)

UnitsMax. capacity Supply air temp. 21°C

80°C/60°C 60°C/40°C 80°C/60°C 60°C/40°C

Air volume m3/h 360 630 360 630 360 630 360 630

Air temp. out* °C 44 40 31 29 21 21 21 21Pressure loss Pa 10 25 10 25 10 25 10 25Capacity kW 3.6 5.3 2.0 3.0 0.74 1.29 0.74 1.28Water flow l/h 144 252 108 144 30 61 40 61Pressure loss, max. KPa 1.0 3.0 1.0 2.0 0.5 1.0 0.7 1.0

*Air in 15°C

** Please be aware that this heater coil has 250mm duct connections, so 2 pcs of Ø200/250mm duct reduction parts are needed for installation with a HCV 700 (Ø200)

Page 28: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

184

R E S I D E N T I A L V E N T I L AT I O N

H C V / H C H ACC E S S O R I E S

Water heating coils

Dimensions and weight

Ød B H Ødy F G K L Weightmm kg

HCV 4 (CWW 125-2-2.5) 125 238 180 10 137 40 276 356 3.5HCV 5/HCH 5 (CWW 160-2-2.5) 160 313 255 10 212 40 276 356 5.4

HCH 8 (CWW 250-2-2.5) 250 398 330 10 250 40 276 356 7.7

Panel filters

Panel filters are supplied as a set with either two G4 filters or one G4 filter and one F7 filter. G4 is standard. F7 filters can be used on the supply air as a pollen filter.

Filters

Ødy

H

F B+8

B

L

KG G

Ød B H Ødy F G K L Weightmm kg

HCV 300 (CWW 125-2-2.5) 125 238 180 10 137 40 276 356 3.5HCV 500/HCV 700 (CWW 160-2-2.5)

160 313 255 10 212 40 276 356 5.4

HCV 700 (CWW 250-2-2.5) 250 398 330 10 250 40 276 356 7.7

Page 29: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

185

TO

CO

NT

RO

L

R E S I D E N T I A L V E N T I L AT I O N CO N T R O L L E R S

CO N T R O L L E R S

Wireless remote control

Wired control

Wired control (HCP 10)

Dantherm offers a pre-wired control unit, which is connected to the ventilation unit with a 6m cable. The wired control comes with a white plastic frame and a metal frame for fastening into a standard junction box. Alternatively Dantherm can supply a box to fix to the wall in an appropriate place.

The HCP 10 wired control gives the user the following options:

� Manual control of air change (step 0-4)

� Control of air change with week program

� Demand controlled air change (if RH and VOC sensors are connected)

� Enable summer mode (only extract air)

� Enable manual bypass (requires an optional mechanical bypass to be mounted)

� Enable fireplace mode

� Reading and resetting of alarms, including filter alarm

The wired HCP 10 control offers the possibility of adjusting the air volumes without using Dantherm’s PC Tool.

Wireless remote control (HRC 3)

Dantherm offers a wireless remote control, which can be mounted on the wall or placed on a shelf. The remote control is designed for the user, but also includes a special installer menu, allowing the installer to do extensive settings, without the use of the PC Tool.

The remote control has an acoustic alarm that will sound when the filters need to be inspected or replaced. This insures correct maintenance even when the HCC 2 unit is set to demand mode, and regular attention is not towards the remote control.

The user features are:

� Fan speed in manual mode.

� Select demand mode (requires RH and/or VOC sensors to be mounted).

� Select week mode and week program 1-11.

� Manually open bypass. It closes again automatically.

� Enable fireplace boost mode. Seven minutes with overpressure inside the house for easy ignition of a fireplace.

� Enable away mode in which the unit decreases permanently to speed 1.

� Enable night mode in which the unit decreases to speed 1. The time night mode can be adjusted.

� Remaining filter period + adjustment of same.

� Temperature readings in all four duct connections, including the remote control’s embedded temperature sensor, as well as relative humidity and quality of the extract air (accessory).

� Setting time and date.

Page 30: Air cooling and water heating Water cooling - PolyAir · PolyAir Engineering Sàrl Champ Cheval 2 CH - 1530 Payerne +41 26 520 75 00 info@polyair.ch ... Fully hermetic rotary compressor

186

R E S I D E N T I A L V E N T I L AT I O N CO N T R O L L E R S

CO N T R O L L E R S

Control panel

The drawing below shows the buttons, LEDs and sound outlets on the control panel which is included with the unit and the remote control which is an optional accessory.

Status LED:Green = OKYellow = change filterRed = system fault

Manual control of fan speedFan speed 01234Fire place function

Acoustic alarm

Manual bypassSummer mode

Nominal air volumeFan step 3 adjusted using potentiometers on rear of the control panel

Automatic demand controlFan speed (0)123

Current fan speedShown for 2 mins. after actuation

Control panel

The HCV units, has an built-in foil based control panel, with four buttons for controls, and nine LED feedback signals.

*Accessory

Auto fanShort press -Week programLong press - Demand*

Warning / AlarmRed LED - AlarmOrange LED - Filter warningLong press - Filter reset

Fan speed LED indication

Manual fanShort press - Fan speed

Long press - fireplace mode

BypassShort press - 6 hours bypass*Long press - Summer mode

PC Tool Kit

Dantherm PC Tool Kit (HPT 1)

The PC Tool Kit contains a USB plug with program and quick guide + USB cable. The Dantherm PC Tool has an installer menu, where the installer can adjust the HCC 2 unit, connect extra accessories, adjust various user settings, read and reset alarms, if any. It also has a user menu, where the user can read and adjust various settings, such as week programs, set points, alarms and historical data about temperatures and air quality (accessory).