Air Conditioning Technical Data Multi branch selector for VRV IV heat recovery EEDEN14-200_4 BS-Q14A

Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

Air Conditioning

Technical DataMulti branch selector for VRV IV heat recovery

EEDEN14-200_4

BS-Q14A

Page 2: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•
Page 3: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessories • BS-Q14A 1

• Accessory • BS-Q14A

TABLE OF CONTENTSBS-Q14A

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Page 4: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

1

2

1 Features

essory essories Q14A ti branc

Acc Acc BS- Mul • Unique range of single and multi BS boxes for flexible and fast design

• Major reduction in installation time thanks to wide range, compact size and light weight multi BS boxes

• Up to 70% smaller and 66% lighter than previous series

• Faster installation thanks to a reduced number of brazing points and wiring

• All indoor units connectable to one BS box

• Less inspection ports needed compared to installing single BS boxes

• Up to 16kW capacity available per port

• Connect up to 250 class unit (28kW) by combining 2 ports

• No limit on unused ports allowing phased installation

• Faster installation thanks to open connection

• Connectable to REYQ-T VRV IV heat recovery units

• Accessories • BS-Q14A

Page 5: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

2

• Accessory • BS-Q14A

2 Specifications

Standard Accessories : Clamps;

Standard Accessories : Insulation tube;

Standard Accessories : Metal clamp for drain hose;

Standard Accessories : Accessory pipe;

Standard Accessories : Sealing material;

Standard Accessories : Stopper pipes;

Standard Accessories : Insulation tube for stopper pipes;

Notes

(1) When connecting indoor units smaller or equal to 50 class (no need to cut the outlet pipe)

(2) When connecting indoor units larger or equal to 63 class (the outlet pipe needs to be cut)

(3) Diameter when using the attached reducer. If the joint does not fit, a reducer is requested (field supply).

(4) Insulators are necessary (field supply) for the triple piping side

(5) Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.

(6) Maximum allowable voltage range variation between phases is 2%.

(7) MCA/MFA: MCA = 1.25 x FLA

(8) MFA ≤ 4 x FLA

(9) Next lower standard fuse rating minimum 15A

(10) Select wire size based on the value of MCA

(11) Instead of a fuse, use a circuit breaker

2-1 Technical Specifications BS4Q14A BS6Q14A BS8Q14A BS10Q14A BS12Q14A BS16Q14A

Power input Cooling Nom. kW 0.043 0.064 0.086 0.107 0.129 0.172

Heating Nom. kW 0.043 0.064 0.086 0.107 0.129 0.172

Maximum number of connectable indoor units 20 30 40 50 60 64

Maximum number of connectable indoor units per branch 5

Number of branches 4 6 8 10 12 16

Maximum capacity index of connectable indoor units 400 600 750

Maximum capacity index of connectable indoor units per branch 140

Dimensions Unit HeightxWidthxDepth

mm 298x370x430 298x580x430 298x820x430 298x1,060x430

Weight Unit kg 17 24 26 35 38 50

Casing Material Galvanised steel plate

Piping connections Outdoor unit Liquid OD mm 9.5 12.7 12.7 §$ 15.9 (3)

15.9 15.9 §$ 19.1 (3)

19.1

Gas OD mm 22.2 §$ 19.1 (3)

28.6 §$ 22.2 (3)

28.6 28.6 §$ 34.9 (3) 34.9

Discharge gas

OD mm 19.1 §$ 15.9 (3)

19.1 §$ 22.2 (3)

19.1 §$ 22.2 (3) §$ 28.6 (3)

28.6

Indoor unit Liquid OD mm 9.5 (1) §$ 6.4 (2)

Gas OD mm 15.9 (1) §$ 12.7 (2)

Sound absorbing thermal insulation Urethane foam, polyethylene foam

2-2 Electrical Specifications BS4Q14A BS6Q14A BS8Q14A BS10Q14A BS12Q14A BS16Q14A

Power supply Phase 1~

Frequency Hz 50

Voltage V 220-440

Voltage range Min. % -10

Max. % 10

Total circuit Minimum circuit amps (MCA) A 0.4 0.6 0.8 1.0 1.2 1.6

Maximum fuse amps (MFA) A 15

• Accessories • BS-Q14A 3

Page 6: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

3

4

3 Safety device settings3 - 1 Safety Device Settings

4D086060

BS-Q14A

MODELSafety devices

PC board fuse

BS4Q14A 250V 3.15A

BS6Q14A 250V 3.15A

BS8Q14A 250V 3.15A

BS10Q14A 250V 3.15A

BS12Q14A 250V 3.15A

BS16Q14A 250V 3.15A

• Accessories • BS-Q14A

Page 7: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

4

• Accessory • BS-Q14A

4 Options4 - 1 Options

BS-Q14A

3D087639

Option name BS4Q14A BS6Q14A BS8Q14A BS10Q14A BS12Q14A BS162Q14A

Closed pipe kit KHFP26A100C

Joint kit KHRP26A1250C

Quiet kit KDDN26A4 KDDN26A8 KDDN26A12 KDDN26A16

• Accessories • BS-Q14A 5

Page 8: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

5

6

5 Dimensional drawings5 - 1 Dimensional Drawings

3D086003

BS4Q14A(Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re10

0 or

more

(Servic

ing

space)

(No

te 10)

(Servic

ing

space)

(No

te 9)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 22.2mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 19.1mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 9.5mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Attached pipe (Note 5, 6) ø 19.1mm brazing connection

13 Attached pipe (Note 5, 6) ø 15.9mm brazing connection

14 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

In case of use attached pipe

Cutting point(Center of connection area)

Connection area

Servicing space

3D086004

BS6Q14A(Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re10

0 or

more

(Servic

ing

space)

(No

te 10)

(Servic

ing

space)

(No

te 9)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 19.1mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 12.7mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Attached pipe (Note 5, 6) ø 22.2mm brazing connection

13 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

In case of use attached pipe

Cutting point(Center of connection area)

Connection area

Servicing space

• Accessories • BS-Q14A

Page 9: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

5

• Accessory • BS-Q14A

5 Dimensional drawings5 - 1 Dimensional Drawings

3D086005

BS8Q14A (Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re100

or

more

(Servic

ing

space)

(No

te 9)

(Servic

ing

space)

(No

te 10)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 19.1mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 12.7mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Attached pipe (Note 5, 6) ø 28.6mm brazing connection

13 Attached pipe (Note 5, 6) ø 22.2mm brazing connection

14 Attached pipe (Note 5, 6) ø 15.9mm brazing connection

15 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

In case of use ø 28.6 attached pipe In case of use ø 22.2 attached pipe

Cutting point(Center of connection area)

Connection area

Servicing space

3D086006

BS10Q14A(Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re10

0 or

more

(Servic

ing

space)

(No

te 10)

(Servic

ing

space)

(No

te 9)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 15.9mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Attached pipe (Note 5, 6) ø 34.9mm brazing connection

13 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

In case of use attached pipe

Cutting point(Center of connection area)

Connection area

Servicing space

• Accessories • BS-Q14A 7

Page 10: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

5

8

5 Dimensional drawings5 - 1 Dimensional Drawings

3D086007

BS12Q14A(Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re10

0 or

more

(Servic

ing

space)

(No

te 10)

(Servic

ing

space)

(No

te 9)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 15.9mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Attached pipe (Note 5, 6) ø 34.9mm brazing connection

13 Attached pipe (Note 5, 6) ø 19.1mm brazing connection

14 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

(Servicing space) (Note 3)

In case of use attached pipe

Cutting point(Center of connection area)

Connection area

Servicing space

3D086008

BS16Q14A(Suspension bolt pitch)

Inspection door

300 or more

500 or more

100

or mo

re10

0 or

more

(Servic

ing

space)

(No

te 9)

(Servic

ing

space)

(No

te 9)

(Servicing space)(Note 9)

(Servicing space) (Note 3) (Note 9)

450 (Note 1)

450 (

Note

7)

No. Parts name Remarks

1 Outdoor unit suction gas pipe connection port (Note 5, 6) ø 34.9mm brazing connection

2 Outdoor unit HP/LP gas pipe connection port (Note 5, 6) ø 28.6mm brazing connection

3 Outdoor unit liquid pipe connection port (Note 5, 6) ø 19.1mm brazing connection

4 Indoor unit gas pipe connection port (Note 4) ø 15.9mm brazing connection

5 Indoor unit gas pipe connection port (Note 4) ø 12.7mm brazing connection

6 Indoor unit liquid pipe connection port (Note 4) ø 9.5mm brazing connection

7 Indoor unit liquid pipe connection port (Note 4) ø 6.4mm brazing connection

8 Electric box (Note 1)

9 Suspension brackets M8~M10

10 Grounding terminal M4

11 Socket for drain VP20 (O, D, ø 26mm/ I, D ø 20mm)

12 Inspection hole

NOTES

1. Be sure to install a inspection door at electric box side. Another door is necessary to unload the product.2. Install it at the place where sound of refrigerant does not disturb. Must not install it at the space such as

roof-space of room where person exists.3. 4. In case of connecting with a 20~50 type indoor unit, there is no need to cut and connect as it is.

In case of others, cut the outlet pipe and connect to the connecting pipe. Refer to above figure.5. Reducer may be required (field supply) if joint diameter does not suit on the triple piping side.6. Insulators are necessary (field supply) for the triple piping side.7. Thas space is a space to keep a top panel when servicing.8. Install it in a place which can be secured downward slope of 1/100 or greater.9. It is a space for removing the drain pan.10. This is a space for removing a top panel when servicing.

(Sus

pens

ion bo

lt pitc

h)

(Servicing space) (Note 3)

Cutting point(Center of connection area)

Connection area

Servicing space

• Accessories • BS-Q14A

Page 11: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

6

• Accessory • BS-Q14A

6 Centre of gravity6 - 1 Centre of Gravity

4D086046

BS4Q14A

4D086047

BS6Q14A

• Accessories • BS-Q14A 9

Page 12: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

6

10

6 Centre of gravity6 - 1 Centre of Gravity

4D086048

BS8Q14A

4D086049

BS10Q14A

• Accessories • BS-Q14A

Page 13: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

6

• Accessory • BS-Q14A

6 Centre of gravity6 - 1 Centre of Gravity

4D086050

BS12Q14A

4D086051

BS16Q14A

• Accessories • BS-Q14A 11

Page 14: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

7

12

7 Piping diagrams7 - 1 Piping Diagrams

3D086032

BS4Q14A Liquid pipe connection port

Suction gas pipeconnection port

Filter

Filter

HP/LP gas pipeconnection port

D unit C unit B unit A unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Elec

tronic

Exp

ansio

n Valv

e (HP

/LP ga

s)

Doub

le pip

e hea

tex

chan

ger

Doub

le pip

e hea

tex

chan

ger

Doub

le pip

e hea

tex

chan

ger

Doub

le pip

e hea

tex

chan

ger

Elec

tronic

Expa

nsion

Valv

e(S

ub co

ol)

Elec

tronic

Expa

nsion

Valv

e(S

ub co

ol)

Elec

tronic

Expa

nsion

Valv

e(S

ub co

ol)

Elec

tronic

Expa

nsion

Valv

e(S

ub co

ol)

Elec

tronic

Exp

ansio

n Valv

e (HP

/LP ga

s)

Elec

tronic

Exp

ansio

n Valv

e (HP

/LP ga

s)

Elec

tronic

Exp

ansio

n Valv

e (HP

/LP ga

s)

Elec

tronic

Exp

ansio

n Valv

e (Su

ction

)

Elec

tronic

Exp

ansio

n Valv

e (Su

ction

)

Elec

tronic

Exp

ansio

n Valv

e (Su

ction

)

Elec

tronic

Exp

ansio

n Valv

e (Su

ction

)

Filter

Filter

Filter

Filter

Filter

Filter

Filter

3D086033

BS6Q14A Liquid pipe connection port

Suction gas pipeconnection port

Filter

Filter

HP/LP gas pipeconnection port

D unitE unitF unit C unit B unit A unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Filter

Filter

Filter

Filter

Filter

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Electr

onic

Expa

nsion

Valve

(Suc

tion)

Filter

Filter

Filter

Filter

Filter

Filter

• Accessories • BS-Q14A

Page 15: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

7

• Accessory • BS-Q14A

7 Piping diagrams7 - 1 Piping Diagrams

3D086034

BS8Q14ALiquid pipe connection port

Suction gas pipeconnection port

Filter

Filter

HP/LP gas pipeconnection port

D unitE unitF unitG unitH unit C unit B unit A unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Electr

onic

Expa

nsion

Valve

(HP/

LP ga

s)

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

3D086035

BS10Q14ALiquid pipe connection port

Suction gas pipeconnection port

Filter

Filter

HP/LP gas pipeconnection port

D unitE unitF unitG unitH unitI unitJ unit C unit B unit A unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

• Accessories • BS-Q14A 13

Page 16: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

7

14

7 Piping diagrams7 - 1 Piping Diagrams

3D086036

BS12Q14A

Liquid pipe connection port

Suction gas pipeconnection port Filter

Filter

HP/LP gas pipeconnection port

D unitE unitF unitG unitH unitI unitJ unitK unitL unit C unit B unit A unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Doub

le pip

e he

at ex

chan

ger

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic

Expa

nsion

Valve

(Sub

cool)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Electr

onic E

xpansi

on Va

lve (S

uction

)

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

3D086037

BS16Q14A

Liquid pipe connection port

Suction gas pipeconnection port

Filter

FilterHP/LP gas pipeconnection port

A unitB unitC unitD unitE unitF unitG unitH unitI unitJ unitK unitL unitM unitN unitO unitP unit

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Gas p

ipeco

nnec

tion p

ort

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Liquid

pipe

conn

ectio

n port

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

FilterEle

ctron

ic Ex

pans

ion Va

lve (H

P/LP g

as)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Electr

onic

Expa

nsion

Valve

(HP/L

P gas

)

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Doub

le pipe

he

at exc

hang

er

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electr

onic

Expa

nsion

Valve

(Sub c

ool)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Electro

nic Ex

pansio

n Valv

e (Suct

ion)

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

Filter

• Accessories • BS-Q14A

Page 17: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

8

• Accessory • BS-Q14A

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

BS4Q14A

NOTES

1 This wiring diagram is for BS units only.2 The marks in this diagram indicate; : Terminal block, :

Connector, : Field wiring, : Earth terminal.3 For wiring for the terminal block X2M X3M (operation), refer to the

installation manual attached to the product.4 The factory setting of dip switch (DS1 DS2) are as follows. For the

setting method of dip switch (DS1 DS2), refer to ‘the installation manual’ and ‘precaution for service’ attached on the control box cover.

5 As for X15A(A1P), remove the short circuit connector and connect the air conditioner stop signal (optional product) when using the drain-up kit (optional product). For details, please refer to the opera-tion manual attached to the kit.

3D086235

Power Supply

A1P Printed circuit board (Control) Y4E Electric expansion valve (Suction)B unitC1 Capacitor Y5E Electric expansion valve (HP/LP Gas)

DS1, DS2 Dip switch Y6E Electric expansion valve (Sub cool)F1U Fuse (T, 3.15A, 250V) Y7E Electric expansion valve (Suction)

C unitHAP Flashing lamp (Service monitor-green) Y8E Electric expansion valve (HP/LP Gas)PS Switching power supply Y9E Electric expansion valve (Sub cool)V1R Diode bridge Y10E Electric expansion valve (Suction)

D unitX1M Terminal strip (Power) Y11E Electric expansion valve (HP/LP Gas)X2M, X3M Terminal strip (Transmission) Y12E Electric expansion valve (Sub cool)Z1FY1E Electric expansion valve (Suction)

A unitY2E Electric expansion valve (HP/LP Gas) Optional accessoriesY3E Electric expansion valve (Sub cool) X15A Connector (drain up kit abnormal signal)

Power supply

indoor(F1) (F2)

A unit

indoor(F1) (F2)

B unit

indoor(F1) (F2)

C unit

indoor(F1) (F2)

D unit

outdoor(F1) (F2)

outdoor unit

BS unit(F1) (F2)BS unit

BS unit(F1) (F2)

(Note3) (Note3) (Note3) (Note3)

(Note3)

(Note3) OR

D unit C unit

A unitB unit

LAYOUT OF EL. COMPO. BOX

X15A Note 5

ON

OFF

ON

ON ON

(note 5)

OFF

OFF OFF

• Accessories • BS-Q14A 15

Page 18: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

8

16

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

BS6-8Q14A

NOTES

1 This wiring diagram is for BS units only.2 The marks in this diagram indicate; : Terminal block, : Connector, : Field wiring, : Earth terminal3 For wiring for the terminal block X2M~X4M (operation), refer to the installation manual attached to the product.4 The factory setting of dip switch (DS1 DS2) are as follows. For the setting method of dip switch (DS1 DS2), refer to ‘the installation manual’ and ‘precaution for service’ attached on the

control box cover.5 As for X15A(A1P), remove the short circuit connector and connect the air conditioner stop signal (optional product) when using the drain-up kit (optional product). For details, please refer to

the operation manual attached to the kit.

A1P, A2P Printed circuit board (Control) Y4E Electric expansion valve (Suction)B unit

Y16E Electric expansion valve (Suction)F unitC1 Capacitor (A1P, A2P) Y5E Electric expansion valve (HP/LP Gas) Y17E Electric expansion valve (HP/LP Gas)

DS1, DS2 Dip switch (A1P, A2P) Y6E Electric expansion valve (Sub cool) Y18E Electric expansion valve (Sub cool)F1U Fuse (T, 3.15A 250V (A1P, A2P) Y7E Electric expansion valve (Suction)

C unitY19E Electric expansion valve (Suction)

G unitHAP Flashing lamp (Service monitor - green) (A1P, A2P) Y8E Electric expansion valve (HP/LP Gas) Y20E Electric expansion valve (HP/LP Gas)PS Switching power supply (A1P, A2P) Y9E Electric expansion valve (Sub cool) Y21E Electric expansion valve (Sub cool)V1R Diode bridge (A1P, A2P) Y10E Electric expansion valve (Suction)

D unitY22E Electric expansion valve (Suction)

H unitX1M Terminal strip (Power) Y11E Electric expansion valve (HP/LP Gas) Y23E Electric expansion valve (HP/LP Gas)X2M~X4M Terminal strip (Transmission) Y12E Electric expansion valve (Sub cool) Y24E Electric expansion valve (Sub cool)Z1F Y13E Electric expansion valve (Suction)

E unitOptional Accessories

Y1E Electric expansion valve (Suction)A unit

Y14E Electric expansion valve (HP/LP Gas) X15A Connector (Drain up kit abnormal signal) (A1P)Y2E Electric expansion valve (HP/LP Gas) Y15E Electric expansion valve (Sub cool)Y3E Electric expansion valve (Sub cool)

Indoor(F1) (F2)

A unit

Indoor(F1) (F2)

B unit

Indoor(F1) (F2)

C unit

Indoor(F1) (F2)

D unit

Indoor(F1) (F2)

E unit

Indoor(F1) (F2)

F unit

Indoor(F1) (F2)

G unit

Indoor(F1) (F2)

H unit

BSunit(F1) (F2)BS unit

BSunit(F1) (F2)

Outdoor(F1) (F2)

Outdoor unit

(Note3) (Note3) (Note3) (Note3) (Note3) (Note3) (Note3) (Note3) (Note3)

(Note3)

(Note3) (Note3) (Note3)

(Note3)

ON ON ON ON

ON ON ON ON

OFF OFF OFF OFF

OFF OFF OFF OFF

2D086236

Power Supply

(Note 5)

OFFOFF OFF OFF

OFF OFF

ON ON ON

ON

TO X4A(A1P)

TO X5A(A1P)

ON

ON

D unit C unit H unit G unit

E unit E unit

F unit

F unit

A unitB unit

Indoor(F1) (F2)

E unit

Indoor(F1) (F2)

F unit

BS unit(F1) (F2)BS unit

BS unit(F1) (F2)

Outdoor(F1) (F2)

Outdoor unit

Case of BS6Q14AV1 Case of BS6Q14AV1

X15A (Note 5)

LAYOUT OF EL. COMPO. BOX

or

or

• Accessories • BS-Q14A

Page 19: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

8

• Accessory • BS-Q14A

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

BS10-12Q14A

NOTES

1 This wiring diagram is for BS units only.2 The marks in this diagram indicate; : Terminal block, : Connector, : Field wiring, : Earth terminal3 For wiring for the terminal block X2M~X5M (operation), refer to the installation manual attached to the product.4 The factory setting of dip switch (DS1 DS2) are as follows. For the setting method of dip switch (DS1 DS2), refer to ‘the installation manual’ and ‘precaution for service’

attached on the control box cover.5 As for X15A(A1P), remove the short circuit connector and connect the air conditioner stop signal (optional product) when using the drain-up kit (optional product).

For details, please refer to the operation manual attached to the kit.

(Note3) (Note3)(Note3)

(Note3)

TO X4A(A2P)

TO X5A(A1P)

BS unit

2D086237

Power Supply

OFF OFF OFF OFF OFF OFF

OFF OFF

ON ON(Note5)

ON ON ON ON

ON ON

D unit C unit H unit L unitG unit K unit

I unit

J unit

F unitE unit

A unitB unit

I unit

J unit

Indoor(F1) (F2)

I unit

Indoor(F1) (F2)

J unit

Outdoor(F1) (F2)

Outdoor unit

BS unit(F1) (F2)BS unit

Case of BS10Q14AV1Case of BS12Q14AV1

X15A (Note 5)

LAYOUT OF EL. COMPO. BOX

(Note3) (Note3) (Note3) (Note3) (Note3)

(Note3)

orIndoor

(F1) (F2)L unit

Indoor(F1) (F2)

K unit

Indoor(F1) (F2)

J unit

Indoor(F1) (F2)

I unit

Outdoor(F1) (F2)

Outdoor unit

BS unit(F1) (F2)BS unit

or

BS unit(F1) (F2)(Note3) (Note3) (Note3) (Note3) (Note3) (Note3) (Note3) (Note3)

Indoor(F1) (F2)

A unit

Indoor(F1) (F2)

B unit

Indoor(F1) (F2)

C unit

Indoor(F1) (F2)

D unit

Indoor(F1) (F2)

E unit

Indoor(F1) (F2)

F unit

Indoor(F1) (F2)

G unit

Indoor(F1) (F2)

H unit

ON ON ON ON

ON ON ON ONOFF OFF OFF OFF

OFF OFF OFF OFF

A1P~A3P Printed circuit board (Control) Y7E Electric expansion valve (Suction)C unit

Y22E Electric expansion valve (Suction)H unitC1 Capacitor (A1P~ A3P) Y8E Electric expansion valve (HP/LP Gas) Y23E Electric expansion valve (HP/LP Gas)

DS1, DS2 Dip switch (A1P~ A3P) Y9E Electric expansion valve (Sub cool) Y24E Electric expansion valve (Sub cool)F1U Fuse (T, 3.15A 250V (A1P~ A3P) Y10E Electric expansion valve (Suction)

D unitY25E Electric expansion valve (Suction)

I unitHAP Flashing lamp (Service monitor - green) (A1P~ A3P) Y11E Electric expansion valve (HP/LP Gas) Y26E Electric expansion valve (HP/LP Gas)PS Switching power supply (A1P~ A3P) Y12E Electric expansion valve (Sub cool) Y27E Electric expansion valve (Sub cool)V1R Diode bridge (A1P~ A3P) Y13E Electric expansion valve (Suction)

E unitY28E Electric expansion valve (Suction)

J unitX1M Terminal strip (Power) Y14E Electric expansion valve (HP/LP Gas) Y29E Electric expansion valve (HP/LP Gas)X2M~X5M Terminal strip (Transmission) Y15E Electric expansion valve (Sub cool) Y30E Electric expansion valve (Sub cool)Z1F Y16E Electric expansion valve (Suction)

F unitY31E Electric expansion valve (Suction)

K unitY1E Electric expansion valve (Suction)A unit

Y17E Electric expansion valve (HP/LP Gas) Y32E Electric expansion valve (HP/LP Gas)Y2E Electric expansion valve (HP/LP Gas) Y18E Electric expansion valve (Sub cool) Y33E Electric expansion valve (Sub cool)Y3E Electric expansion valve (Sub cool) Y19E Electric expansion valve (Suction)

G unitY34E Electric expansion valve (Suction)

L unitY4E Electric expansion valve (Suction)B unit

Y20E Electric expansion valve (HP/LP Gas) Y35E Electric expansion valve (HP/LP Gas)Y5E Electric expansion valve (HP/LP Gas) Y21E Electric expansion valve (Sub cool) Y36E Electric expansion valve (Sub cool)Y6E Electric expansion valve (Sub cool) Optional Accessories

X15A Connector (Drain up kit abnormal signal) (A1P)

• Accessories • BS-Q14A 17

Page 20: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

• Accessory • BS-Q14A

8

18

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

BS16Q14A

NOTES

1 This wiring diagram is for BS units only.2 The marks in this diagram indicate; : Terminal block, : Connector, : Field wiring, : Earth terminal3 For wiring for the terminal block X2M~X6M (operation), refer to the installation manual attached to the product.4 The factory setting of dip switch (DS1 DS2) are as follows. For the setting method of dip switch (DS1 DS2), refer to ‘the installation manual’ and ‘precaution for service’

attached on the control box cover.5 As for X15A(A1P), remove the short circuit connector and connect the air conditioner stop signal (optional product) when using the drain-up kit (optional product).

For details, please refer to the operation manual attached to the kit.

2D086238

Power Supply

OFF OFF OFF OFF OFF OFF OFF OFFON ON ON ON ON ON ON ON

(Note5)

D unit C unit H unit L unitG unit K unit P unit O unit

M unit

J unit

F unitE unit

A unitB unit

I unit

N unit

Indoor(F1) (F2)

M unit

Indoor(F1) (F2)

N unit

Indoor(F1) (F2)

O unit

Indoor(F1) (F2)

P unit

Outdoor(F1) (F2)

Outdoor unit

BS unit(F1) (F2)BS unit

X15A (Note 5)

LAYOUT OF EL. COMPO. BOX

(Note3) (Note3) (Note3) (Note3) (Note3)

(Note3)

(Note3) (Note3) (Note3)or

Indoor(F1) (F2)

L unit

Indoor(F1) (F2)

K unit

Indoor(F1) (F2)

J unit

Indoor(F1) (F2)

I unit

or

BS unit(F1) (F2)(Note3) (Note3) (Note3) (Note3) (Note3)(Note3)(Note3) (Note3)

Indoor(F1) (F2)

A unit

Indoor(F1) (F2)

B unit

Indoor(F1) (F2)

C unit

Indoor(F1) (F2)

D unit

Indoor(F1) (F2)

E unit

Indoor(F1) (F2)

F unit

Indoor(F1) (F2)

G unit

Indoor(F1) (F2)

H unit

ON ON

OFF OFF

A1P~A4P Printed circuit board (Control) Y13E Electric expansion valve (Suction)E unit

Y34E Electric expansion valve (Suction)L unitC1 Capacitor (A1P~ A4P) Y14E Electric expansion valve (HP/LP Gas) Y35E Electric expansion valve (HP/LP Gas)

DS1, DS2 Dip switch (A1P~ A4P) Y15E Electric expansion valve (Sub cool) Y36E Electric expansion valve (Sub cool)F1U Fuse (T, 3.15A 250V (A1P~ A4P) Y16E Electric expansion valve (Suction)

F unitY37E Electric expansion valve (Suction)

M unitHAP Flashing lamp (Service monitor - green) (A1P~ A4P) Y17E Electric expansion valve (HP/LP Gas) Y38E Electric expansion valve (HP/LP Gas)PS Switching power supply (A1P~ A4P) Y18E Electric expansion valve (Sub cool) Y39E Electric expansion valve (Sub cool)V1R Diode bridge (A1P~ A4P) Y19E Electric expansion valve (Suction)

G unitY40E Electric expansion valve (Suction)

N unitX1M Terminal strip (Power) Y20E Electric expansion valve (HP/LP Gas) Y41E Electric expansion valve (HP/LP Gas)X2M~X6M Terminal strip (Transmission) Y21E Electric expansion valve (Sub cool) Y42E Electric expansion valve (Sub cool)Z1F Y22E Electric expansion valve (Suction)

H unitY43E Electric expansion valve (Suction)

O unitY1E Electric expansion valve (Suction)A unit

Y23E Electric expansion valve (HP/LP Gas) Y44E Electric expansion valve (HP/LP Gas)Y2E Electric expansion valve (HP/LP Gas) Y24E Electric expansion valve (Sub cool) Y45E Electric expansion valve (Sub cool)Y3E Electric expansion valve (Sub cool) Y25E Electric expansion valve (Suction)

I unitY46E Electric expansion valve (Suction)

P unitY4E Electric expansion valve (Suction)B unit

Y26E Electric expansion valve (HP/LP Gas) Y47E Electric expansion valve (HP/LP Gas)Y5E Electric expansion valve (HP/LP Gas) Y27E Electric expansion valve (Sub cool) Y48E Electric expansion valve (Sub cool)Y6E Electric expansion valve (Sub cool) Y28E Electric expansion valve (Suction)

J unitOptional Accessories

Y7E Electric expansion valve (Suction)C unit

Y29E Electric expansion valve (HP/LP Gas) X15A Connector (Drain up kit abnormal signal) (A1P)Y8E Electric expansion valve (HP/LP Gas) Y30E Electric expansion valve (Sub cool)Y9E Electric expansion valve (Sub cool) Y31E Electric expansion valve (Suction)

K unitY10E Electric expansion valve (Suction)D unit

Y32E Electric expansion valve (HP/LP Gas)Y11E Electric expansion valve (HP/LP Gas) Y33E Electric expansion valve (Sub cool)Y12E Electric expansion valve (Sub cool)

• Accessories • BS-Q14A

Page 21: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

3

9

• Accessory • BS-Q14A

9 Sound data9 - 1 Sound Pressure Spectrum

BS4Q14A

4D087632

NOTES

1 The operating sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound

2 Even if the indoor unit to be connected downstream of bs unit has stopped, when the system is operating, operating sound can be heard.

3 The maximum sound is max value of transient sound, such as oil return and defrost, the change of cooling and heating, etc.

4 Operating conditions:Power source: 220-240V 50Hz

5 Measuring place: Anechoic chamber (conversion value)6 Location of microphone:

Octav

e ban

d sou

nd pr

essu

re le

vel d

B (0

dB =

0.000

2μ ba

r)

Octave band center frequency (Hz)

Approximate threshold hearing for continuous noise

Scale Operating sound

Max sound

A 38 45C 39 46

Max sound

Operating sound

The operated sound is measured when the indoor units are connected to all the branches.

Over all (db)

BS6-8Q14A

4D087633

NOTES

1 The operating sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound

2 Even if the indoor unit to be connected downstream of bs unit has stopped, when the system is operating, operating sound can be heard.

3 The maximum sound is max value of transient sound, such as oil return and defrost, the change of cooling and heating, etc.

4 Operating conditions:Power source: 220-240V 50Hz

5 Measuring place: Anechoic chamber (conversion value)6 Location of microphone:

Octav

e ban

d sou

nd pr

essu

re le

vel d

B (0

dB =

0.000

2μ ba

r)

Octave band center frequency (Hz)

Approximate threshold hearing for continuous noise

Scale Operating sound

Max sound

A 39 47C 39 48

Max sound

Operating sound

The operated sound is measured when the indoor units are connected to all the branches.

Over all (db)

BS10-12Q14A

4D087634

NOTES

1 The operating sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound

2 Even if the indoor unit to be connected downstream of bs unit has stopped, when the system is operating, operating sound can be heard.

3 The maximum sound is max value of transient sound, such as oil return and defrost, the change of cooling and heating, etc.

4 Operating conditions:Power source: 220-240V 50Hz

5 Measuring place: Anechoic chamber (conversion value)6 Location of microphone:

Octav

e ban

d sou

nd pr

essu

re le

vel d

B (0

dB =

0.000

2μ ba

r)

Octave band center frequency (Hz)

Approximate threshold hearing for continuous noise

Scale Operating sound

Max sound

A 40 48C 40 48

Max sound

Operating sound

The operated sound is measured when the indoor units are connected to all the branches.

Over all (db)

BS16Q14A

4D087635

NOTES

1 The operating sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound

2 Even if the indoor unit to be connected downstream of bs unit has stopped, when the system is operating, operating sound can be heard.

3 The maximum sound is max value of transient sound, such as oil return and defrost, the change of cooling and heating, etc.

4 Operating conditions:Power source: 220-240V 50Hz

5 Measuring place: Anechoic chamber (conversion value)6 Location of microphone:

Octav

e ban

d sou

nd pr

essu

re le

vel d

B (0

dB =

0.000

2μ ba

r)

Octave band center frequency (Hz)

Approximate threshold hearing for continuous noise

Scale Operating sound

Max sound

A 41 49C 41 49

Max sound

Operating sound

The operated sound is measured when the indoor units are connected to all the branches.

Over all (db)

• Accessories • BS-Q14A 19

Page 22: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•
Page 23: Air Conditioning Technical Data - Daikin Vrv · 2020. 3. 3. · • Accessory • BS-Q14A 1 2 • Accessories • BS-Q14A 1 Features c n s a e r yi br oAMs4 i s1 t eQ l c- cSu AB•

These products are not within the scope ofthe Eurovent certification program

EE

DE

N1

4-2

00_

4

• 1

0/1

4 •

Co

pyr

igh

t D

aik

in

Th

e p

rese

nt p

ub

lica

tion

su

per

sed

es E

ED

EN

13

-20

0_

4

The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leaflet to the best of its knowledge. Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe N.V.

BARCODE Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende