29
Air Conditioning Technical Data EEDEN14-131 AZQS-BY1

Air Conditioning Technical Data - tinlavir.ro€¦ · 2 • Split - Sky Air • AZQS-BY1 1 Features k i S n U - 1 r Y o tB o - i d S l t Q upZ OSA• Daikin outdoor units are neat,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Air Conditioning

    Technical Data

    EEDEN14-131

    AZQS-BY1

  • • Split - Sky Air • AZQS-BY1 1

    • Outdoor Unit • AZQS-BY1

    TABLE OF CONTENTSAZQS-BY1

    1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

    2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

    3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

    4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    5 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    6 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Cooling Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Capacity Correction Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    7 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    8 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    9 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    10 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Wiring Diagrams - Three Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    11 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Sound Power Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Sound Pressure Spectrum Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

    12 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

    13 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

  • • Outdoor Unit • AZQS-BY1

    1

    2

    1 Features

    door Uni it - Sk S-BY1

    Out Spl AZQ • Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall

    • Energy efficient units: full range A class energy labels

    • Outdoor units are fitted with either a swing or scroll compressor, renowned for low noise and high energy efficiency

    • Outdoor units for pair application

    • Seasonal efficiency, optimized for all seasons.

    • Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season.

    Inverter Energy efficiency

    Auto cooling-heating

    changeover

    • Split - Sky Air • AZQS-BY1

  • 3

    2

    • Outdoor Unit • AZQS-BY1

    2 Specifications

    Notes

    (1) EER/COP according to Eurovent 2012

    Notes

    (1) EER/COP according to Eurovent 2012

    2-1 Nominal Capacity And Nominal Input ABQ125A/AZQS125BY1 ABQ140A/AZQS140BY1Cooling capacity Nom. kW 12.1 13.0Heating capacity Nom. kW 13.5 15.5Seasonal efficiency (according to EN14825)

    Cooling Energy label -Pdesign kW -SEER -Annual energy consumption

    kWh -

    Heating (Average climate)

    Energy label -Pdesign kW -SCOP -Annual energy consumption

    kWh -

    Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

    EER 2.91 3.01COP 3.41Annual energy consumption kWh 2,079 2,159Energy label Cooling C B

    Heating B

    2-2 Nominal Capacity And Nominal Input AHQ100C/AZQS100BY1 AHQ125C/AZQS125BY1 AHQ140C/AZQS140BY1Cooling capacity Nom. kW 9.5 12.1 13.0Heating capacity Nom. kW 10.8 13.5 15.5Seasonal efficiency (according to EN14825)

    Cooling Energy label B -Pdesign kW 9.50 -SEER 4.60 -Annual energy consumption

    kWh 723 -

    Heating (Average climate)

    Energy label A -Pdesign kW 7.60 -SCOP 3.80 -Annual energy consumption

    kWh 2,800 -

    Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

    EER 2.62 2.63 3.01COP 3.41 3.61 3.41Annual energy consumption kWh 1,810 2,300 2,159Energy label Cooling D B

    Heating B A B

    2-3 Nominal Capacity And Nominal Input ACQ100C/AZQS100BY1 ACQ125C/AZQS125BY1Cooling capacity Nom. kW 9.5 12.1Heating capacity Nom. kW 10.8 13.5Seasonal efficiency (according to EN14825)

    Cooling Energy label B -Pdesign kW 9.50 -SEER 4.65 -Annual energy consumption

    kWh 716 -

    Heating (Average climate)

    Energy label A -Pdesign kW 7.60 -SCOP 3.80 -Annual energy consumption

    kWh 2,800 -

    • Split - Sky Air • AZQS-BY1 3

  • • Outdoor Unit • AZQS-BY1

    2

    4

    2 Specifications

    Notes

    (1) EER/COP according to Eurovent 2012

    Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load)

    EER 3.21 3.01COP 3.61 3.41Annual energy consumption kWh 1,480 2,010Energy label Cooling A B

    Heating A B

    2-4 Technical Specifications AZQS100BY1 AZQS125BY1 AZQS140BY1Capacity control Method Inverter controlledCasing Colour Ivory white

    Material Painted galvanized steel plateDimensions Unit Height mm 990 1,430

    Width mm 940Depth mm 320

    Packed unit Height mm 1,170 1,610Width mm 1,015Depth mm 422

    Weight Unit kg 82 101Packed unit kg 88 108

    Heat exchanger Fin Type WF finTreatment Anti-corrosion treatment (PE)

    Compressor Quantity 1Type Hermetically sealed swing compressorStarting method Inverter driven

    Fan Type Propeller fanDischarge direction HorizontalQuantity 1 2Air flow rate Cooling Nom. m³/min 76 77 83

    Super low

    m³/min -cfm -

    Heating Nom. m³/min 83 62Super low

    m³/min -cfm -

    Fan motor Quantity 1 2Model Brushless DC motorOutput W 200 94Drive Direct driveSpeed Cooling Super

    lowrpm -

    Heating Super low

    rpm -

    Sound power level Cooling Nom. dBA 70 71 70Sound pressure level Cooling Nom. dBA 53 54 53

    Heating Nom. dBA 57 58 54Night quiet mode Level 1 dBA 49

    Operation range Cooling Ambient

    Min. °CDB -5Max. °CDB 46

    Heating Ambient

    Min. °CWB -15Max. °CWB 15.5

    Refrigerant Type R-410ACharge kg 2.9 4.0Control Expansion valve (electronic type)GWP 1,975Circuits Quantity 1

    Refrigerant oil Type FVC50KCharged volume l 0.9 1.35

    2-3 Nominal Capacity And Nominal Input ACQ100C/AZQS100BY1 ACQ125C/AZQS125BY1

    • Split - Sky Air • AZQS-BY1

  • 3

    2

    • Outdoor Unit • AZQS-BY1

    2 Specifications

    Notes

    (1) See separate drawings for electrical data (2) PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC

    Piping connections Liquid Quantity 1Type Flare connectionOD mm 9.52

    Gas Quantity 1Type Flare connectionOD mm 15.9

    Drain Quantity 5Type HoleID mm -OD mm 26

    Piping length OU - IU Min. m 5Max. m 50

    System Equivalent

    m 70

    Chargeless

    m 30

    Additional refrigerant charge kg/m See installation manualLevel difference IU - OU Max. m 30.0

    IU - IU Max. m 0.5Heat insulation Both liquid and gas pipes

    Defrost method Reversed cycleDefrost control Sensor for outdoor heat exchanger temperatureSafety devices Item 01 High pressure switch

    02 Fan motor thermal protection03 Fuse

    2-5 Electrical Specifications AZQS100BY1 AZQS125BY1 AZQS140BY1Power supply Name Y1

    Phase 3N~Frequency Hz 50Voltage V 380-415Voltage range Min. % -10

    Max. % 10Current Zmax List Complies to EN61000-3-11

    Recommended fuses A 20Current - 50Hz Maximum fuse amps (MFA) A -Current - 60Hz Maximum fuse amps (MFA) A -Wiring connections For power supply Remark See installation manual outdoor unit

    For connection with indoor

    Remark See installation manual outdoor unit

    Power supply intake Outdoor unit only

    2-4 Technical Specifications AZQS100BY1 AZQS125BY1 AZQS140BY1

    • Split - Sky Air • AZQS-BY1 5

  • • Outdoor Unit • AZQS-BY1

    3

    6

    3 Electrical data3 - 1 Electrical Data

    • Split - Sky Air • AZQS-BY1

  • 3

    4

    • Outdoor Unit • AZQS-BY1

    4 Options4 - 1 Options

    • Split - Sky Air • AZQS-BY1 7

  • • Outdoor Unit • AZQS-BY1

    5

    8

    5 Combination table5 - 1 Combination Table

    • Split - Sky Air • AZQS-BY1

  • 3

    6

    • Outdoor Unit • AZQS-BY1

    6 Capacity tables6 - 1 Cooling Capacity Tables

    • Split - Sky Air • AZQS-BY1 9

  • • Outdoor Unit • AZQS-BY1

    6

    10

    6 Capacity tables6 - 1 Cooling Capacity Tables

    • Split - Sky Air • AZQS-BY1

  • 3

    6

    • Outdoor Unit • AZQS-BY1

    6 Capacity tables6 - 1 Cooling Capacity Tables

    • Split - Sky Air • AZQS-BY1 11

  • • Outdoor Unit • AZQS-BY1

    6

    12

    6 Capacity tables6 - 2 Heating Capacity Tables

    • Split - Sky Air • AZQS-BY1

  • 3

    6

    • Outdoor Unit • AZQS-BY1

    6 Capacity tables6 - 2 Heating Capacity Tables

    • Split - Sky Air • AZQS-BY1 13

  • • Outdoor Unit • AZQS-BY1

    6

    14

    6 Capacity tables6 - 2 Heating Capacity Tables

    • Split - Sky Air • AZQS-BY1

  • 3

    6

    • Outdoor Unit • AZQS-BY1

    6 Capacity tables6 - 3 Capacity Correction Factor

    • Split - Sky Air • AZQS-BY1 15

  • • Outdoor Unit • AZQS-BY1

    7

    16

    7 Dimensional drawings7 - 1 Dimensional Drawings

    • Split - Sky Air • AZQS-BY1

  • 3

    8

    • Outdoor Unit • AZQS-BY1

    8 Centre of gravity8 - 1 Centre of Gravity

    • Split - Sky Air • AZQS-BY1 17

  • • Outdoor Unit • AZQS-BY1

    9

    18

    9 Piping diagrams9 - 1 Piping Diagrams

    • Split - Sky Air • AZQS-BY1

  • 3

    10

    • Outdoor Unit • AZQS-BY1

    10 Wiring diagrams10 - 1 Wiring Diagrams - Three Phase

    • Split - Sky Air • AZQS-BY1 19

  • • Outdoor Unit • AZQS-BY1

    11

    20

    11 Sound data11 - 1 Sound Power Spectrum

    • Split - Sky Air • AZQS-BY1

  • 3

    11

    • Outdoor Unit • AZQS-BY1

    11 Sound data11 - 2 Sound Pressure Spectrum - Cooling

    • Split - Sky Air • AZQS-BY1 21

  • • Outdoor Unit • AZQS-BY1

    11

    22

    11 Sound data11 - 3 Sound Pressure Spectrum - Heating

    • Split - Sky Air • AZQS-BY1

  • 3

    11

    • Outdoor Unit • AZQS-BY1

    11 Sound data11 - 4 Sound Pressure Spectrum Quiet Mode

    • Split - Sky Air • AZQS-BY1 23

  • • Outdoor Unit • AZQS-BY1

    12

    24

    12 Installation12 - 1 Installation Method

    • Split - Sky Air • AZQS-BY1

  • 3

    12

    • Outdoor Unit • AZQS-BY1

    12 Installation12 - 1 Installation Method

    • Split - Sky Air • AZQS-BY1 25

  • • Outdoor Unit • AZQS-BY1

    13

    26

    13 Operation range13 - 1 Operation Range

    • Split - Sky Air • AZQS-BY1

  • Daikin Europe N.V. participates in the Eu-rovent Certification programme for LiquidChilling Packages (LCP), Air handling units(AHU) and Fan coil units (FCU), Check on-going validity of certificate online: www.eu-rovent-certification.com or using:www.certiflash.com

    EED

    EN

    14-1

    31

    • 11/

    13 •

    Cop

    yrig

    ht D

    aiki

    n Th

    e pr

    esen

    t pub

    licat

    ion

    supe

    rsed

    es E

    EDEN

    13-1

    31The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leaflet to the best of its knowledge. Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe N.V.

    BARCODE Daikin products are distributed by:

    Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

    Air ConditioningTechnical DataAZQS-BY1

    1 Features2 Specifications2-1 Nominal Capacity And Nominal Input2-2 Nominal Capacity And Nominal Input2-3 Nominal Capacity And Nominal Input2-4 Technical Specifications2-5 Electrical Specifications

    3 Electrical data4 Options5 Combination table6 Capacity tables6 - 1 Cooling Capacity Tables6 - 2 Heating Capacity Tables6 - 3 Capacity Correction Factor

    7 Dimensional drawings8 Centre of gravity9 Piping diagrams10 Wiring diagrams10 - 1 Wiring Diagrams - Three Phase

    11 Sound data11 - 1 Sound Power Spectrum11 - 2 Sound Pressure Spectrum - Cooling11 - 3 Sound Pressure Spectrum - Heating11 - 4 Sound Pressure Spectrum Quiet Mode

    12 Installation12 - 1 Installation Method

    13 Operation range