2
The number of stars displayed on the energy label. Available stars are between a minimum of one and a maximum of ten. It is considered as an indication of the claimed energy efficiency of a model at rated conditions. A higher star rating indicates a higher energy efficiency. It is derived from the actual measured EER.Our models has reached the highest energy efficiency level that is now shown on energy labels in Saudi Arabia.
New Energy Labelling Requirement SASO2663/2014
Energy rating classification
18.116.815.614.513.412.411.510 9.7 9 8.5
>>>>>>>>>>>>
EEREEREEREEREEREEREEREEREEREEREEREEREER
>
18.116.815.614.513.412.411.510 9.7 9 8.5 7.5 7.5
109.59
8.58
7.57654321
Star RatingEER limits (rested value)
(Btu/h)/ w at T1
Example of Label -Cooling only
ENERGY EFFICIENCY CLASSIFICATION
R22 depletes the ozone layer, however, R410A is energy-efficient refrigerant with ODP “0” .
NEW REFRIGERANT
18,00024,000
Duct Type
Wall Mounted Type RSA18FMTA-SRSA18UMTA-S
Capacity (BTU/h)
RSA24FMTA-SRSA24UMTA-S
RDA18FMTA-SRDA18UMTA-S
SASO2663/2014
R410AR22
3
PRODUCT SUMMARY
HYPER TROPICAL SPEC
1.Improvement of compressor drive materials for greater durability (Hardness increased).
2.Use of high efficiency, high torque motor
3.Complete protection functions against abnormal temperature rise and abnormal pressure rise
Main features
HYPER TROPICAL COMPRESSOR
SUPER PROTECTION(for Cooling type of Split)
Enhancement of protection function
Strong blue finAdoption of strong blue fin provides strong protection against rust and salt damage.
Super powerMore capacity than old models under overload condition (52°C).
Super low voltage operationOur Hyper Tropical Compressor can be operated even at low voltage.
Super Hi-EERHighly energy efficiency
Super quietSelect the lower noise level.
Temperature rise prevention device (thermal protector) installed
Gas leak protection and low voltage protection OLP (Over Load Protection) device installed
High-output torque motor Torque improved by increasing the thickness of the laminated core and
improving the coil winding
High durability vaneSurface hardness increased
High durability rolling piston Hardness improved by changing the material
High durability crankshaft used Hardness improved by adding a coating
RDA60FHTB-SRDA60UHTB-S
RDA50FMTB-SRDA50UMTB-S
RDA40FMTB-SRDA40UMTB-S
25,00040,00050,00060,000
RDA25FMTA-SRDA25UMTA-S
NEWNEWNEW
RSA18FMTA-SROA18FMTAHS
230/1/607
5,45018,6001,610
7.411.55
1.9(3.3)
4,66015,9001,920
8.68.28
16.0985
320×998×23815(33)
650 x 830 x 32050(110)
230/1/607.5
5,35018,3001,590
7.411.51
2.0(3.5)
4,57015,6001,880
8.48.30
5,4501,560
7.23.49415.0985
320×998×23815(33)
830 x 900 x 33063(139)
RSA18UMTA-SROA18UMTAHS
WALL MOUNTED Type
4
5 speed control
5-speed control provides a variety of airflow and quiet operation.
High energy efficiency
Awarded the highes rank of 6-Star in SASO Energy Saving program in Saudi Arabia.
FMTA Model FMTA
Powerful High Med Low Quiet
10.0 at T1 condition is the minimum figure to award 6-Star, which is the highest rank.
Handy Type
RSA24UMTA-SRSA24FMTA-SRSA18UMTA-S
RSA18FMTA-S
ForRSA18FMTA-S
ForRSA18UMTA-SRSA24FMTA-SRSA24UMTA-S
Cooling model
EER (T1)
11.55
11.53 24 Class
18 Class
6-star 10.0
Quick cooling Quiet
6
106T135 EER
Cooling Cooling/Heating
RSA24FMTA-SRSA24UMTA-S
Cooling Cooling/Heating
RSA18UMTA-SRSA18FMTA-S
V/Ø/Hz
WBtu/h
WA
Btu/h-WI/h(pints/h)
WBtu/h
WA
Btu/h-W
WWA
W/WA
m3/hmm
kg(lbs)mm
kg(lbs)
Model Name
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.T1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Heating (T1 condition)CapacityInput PowerCurrentCOP
Max. Running Current (Cooling)Airflow Rate
DimensionsH×W×DWeight
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
230/1/607
6,60022,6001,960
8.711.53
2.5(4.4)
5,70019,5002,35010.48.30
6,9501,950
93.5618.5
1,150320×998×238
15(33)830×900×330
64(141)
RSA24UMTA-SROA24UMTAHS
(TENTATIVE)SPECIFICATIONS (SPLIT TYPE)
WALL MOUNTED Type
230/1/607
6,60022,6001,960
8.711.531
2.5(4.4)
5,70019,5002,35010.4
8.298
18.51,150
320×998×23815(33)
830 x 900 x 33064(141)
RSA24FMTA-SROA24FMTAHS
Type
5
Double auto swingQuiet operation (Cooling model)
Indoor unitQuiet cooling mode
Outdoor unit
18 type 53 db(A)
54 db(A)
35 db(A)
35 db(A)24 type 6-step 5-step
WALL MOUNTED TYPEVertical and horizontal symmetrical design matched to the interior decor
15 M
New super cooling
15M Long-reach airflow
Powerful Airflow
Direct airflow from top
High efficiency DC Fan motor
Large power diffuser
• Note : Specifications are based on the following conditions. Cooling (SASO2681.T1) : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. Cooling (SASO2681.T3) : Indoor temperature of 29°CDB / 19°CWB, and outdoor temperature of 46°CDB / 24°CWB. Heating (SASO2681.T1) : Indoor temperature of 20°CDB, and outdoor temperature of 7°CDB / 6°CWB• The protective function might work when using it in environment out of the temperature range mentioned above.• The maximum current is the maximum value when operated within the operation range.
(TENTATIVE)
V/Ø/Hz
WBtu/h
WA
Btu/h-WI/h(pints/h)
WBtu/h
WA
Btu/h-W
WWA
W/WA
m3/hmm
kg(lbs)mm
kg(lbs)
400/3/60
SPECIFICATIONS (DUCT TYPE)
230/1/60
Type
Model Name
Power SourceEnergy LabelCooling (T1 condition)
Capacity
Input PowerCurrentEERMoisture Removal
Cooling (T3 condition)
Capacity
Input PowerCurrentEER
Heating (T1 condition)CapacityInput PowerCurrentCOP
Max. Running CurrentAirflow Rate
DimensionsH×W×DWeight
Indoor unit(High)
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
Duct Type
15,20052,0004,520
911.50
4.0(7.0)
13,50046,0005,550
108.29
3,350360×1,400×700
54(118)1,290×900×330
104(224)
RDA60FHTB-SROA60FRTBSS
7
14.5
RDA60UHTB-SROA60URTBSS
7
14,0003,500
74.0014.5
12,40042,4003,680
6.311.52
3.2(5.6)
11,20038,1004,600
7.58.28
2,500300×1,400×700
44(97)1,290×900×330
7
11.5
100(220)
RDA50FMTB-SROA50FRTBSS
7
12,7003,350
5.83.7911.5
102(224)
RDA50UMTB-SROA50URTBSS
11,00037,5003,26015.0
11.503.1(5.5)
9,67033,0003,98018.58.29
2,000300×1,400×700
44(97)1,290×900×330
7
23.0
103(227)
RDA40FMTB-SROA40FBTBSS
7
11,3003,15014.53.5923.0
105(232)
RDA40UMTB-SROA40URTBSS
6,70022,9001,990
8.811.51
2.3(4.0)
5,80019,8002,39010.58.28
1,200270×1,135×700
38(84)830×900×330
7
6,9001,900
8.63.6318.5
65(143)
RDA25UMTA-SROA25UBTAHS
7
18.5
65(143)
RDA25FMTA-SROA25FBTAHS
1,000270×1,135×700
38(84)
7
5,35018,3001,590
7.411.51
1.5(2.6)
4,63015,8001,900
8.68.32
5,3001,550
7.03.4215.0
830×900×33064(141)
RDA18UMTA-SROA18UBTAHS
7
5,45018,7001,620
7.411.54
1.6(2.8)
4,75016,2001,950
8.78.31
16.0
650×830×32050(110)
RDA18FMTA-SROA18FBTAHS
6
Ultra thin duct air conditioner for very low ceilings
DUCT TYPE
Cooling Cooling/Heating
RDA25UMTA-SRDA25FMTA-S
Cooling Cooling/Heating
RDA18UMTA-SRDA18FMTA-S
Cooling Cooling/Heating
RDA50UMTB-SRDA50FMTB-S
Cooling Cooling/Heating
RDA40UMTB-SRDA40FMTB-S
RDA25UMTA-SRDA25FMTA-SRDA18UMTA-S
RDA18FMTA-S
ForRDA18FMTA-S
ForRDA18UMTA-SRDA25FMTA-SRDA25UMTA-S
Wired Type(With Weekly Timer)
Wired Type(With Weekly Timer)
Wired Type(With Weekly Timer)
NEW
Cooling Cooling/Heating
RDA60UHTB-SRDA60FHTB-S
NEW
7
FEATURE SUMMARY FOR SPLIT TYPE
RDA40FMTB-SRDA40UMTB-SRDA50FMTB-SRDA50UMTB-SRDA60FHTB-SRDA60UHTB-S
RDA18FMTB-SRDA18UMTB-SRDA25FMTB-SRDA25UMTB-S
RSA18FMTA-SRSA18UMTA-SRSA24FMTA-SRSA24UMTA-S
ModelDoubleSwingAutomatic
MoistureRemoval
AutomaticLouvers
Auto ShutLouvers
Automatic fan speed
AutoRestart
SleepTimer
WeeklyTimer
ConnectableFresh AirDuct
Connectable DistributingDuct
Feature
ProgramTimer
Powerful Mode
EconomyMode
EXPLANATION OF FEATURES
Program TimerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON
Auto RestartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before once the power supply is restored.
Economy ModeThermostat setting automatically changesaccording to the temperature to avoidunnecessary cooling and heating.
Moisture RemovalThe computer effectively dehumidifies the air.
Double Swing AutomaticComplex swing action of louvers enables automatically to swing both horizontal and vertical directions.
Auto-Shut LouversThe auto shut louvers close or open automatically when the unit stops or starts.
Weekly TimerDifferent on-off times can be set for each day.
Powerful ModeOperates at maximum air flow in the cool and fan operation modes, and quickly makes the room comfortable.
Sleep Timer The micro-computer gradually changes the room temperature automatically to help you enjoy a comfortable night's sleep.
Automatic LouversThe position of the louvers is set automatically to match the operating mode. The louvers can also be adjusted using the remote controller.
Automatic fan speedThe micro-computer automatically adjusts the airflow effectively and properly according to the changes of room temperature.
3MJS06-1502EACopyright© 2004-2015 Fuji Furukawa Engineering & Construction Co.Ltd. All rights reserved.
Manufacturer: Distributor:
Basic Electronics Company LtdTel +966 - 3 - 8642222 Fax + 966 - 3 - 8644516www.al-asasyah.com - [email protected] Box 1402 - Al-Khobar 31952 -Saudi Arabia