Modulens EN Gas fired floor-standing condensing boiler AGC 10/15 AGC 15 AGC 25 AGC 35 User Guide 300026080-001-07

AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Modulens EN

Gas fired floor-standing condensing boiler

AGC 1015AGC 15AGC 25AGC 35

User Guide

300026080-001-07

Contents

1 Safety instructions 411 General safety instructions 4

12 Recommendations 5

13 Liabilities 6131 Manufacturerrsquos liability 6132 Installerrsquos liability 7133 Userrsquos liability 7

2 About this manual 821 Symbols used 8

211 Symbols used in the manual 8212 Symbols used on the equipment 8

22 Abbreviations 9

3 Technical specifications 1031 Certifications 10

32 Technical specifications 10

4 Description 1241 Operating principle 12

411 Gasair setting 12412 Combustion 12

42 Main parts 13

43 Control panel 14431 Description of the keys 14432 Description of the display 15433 Browsing in the menus 17

5 Operating the appliance 1951 Putting the appliance into operation 19

52 Reading out measured values 19

53 Changing the settings 21531 Setting the set point temperatures 21532 Selecting the operating mode 21533 Forcing domestic hot water production 22534 Setting the contrast and lighting on the

display 23

1 15032016 - 300026080-001-07

535 Setting the time and date 23536 Selecting a timer programme 24537 Customising a timer programme 24

54 Installation shutdown 26

55 Antifreeze protection 26

6 Checking and maintenance 2861 General instructions 28

62 Periodic checks 28

7 Troubleshooting 3071 Anti-hunting 30

72 Messages (Code type Bxx or Mxx) 30

73 Faults (Code type Lxx or Dxx) 32

8 Energy savings 3881 Energy-saving advice 38

82 Recommendations 38

9 Warranty 3991 General 39

92 Warranty terms 39

10 Appendix ndash Information on the Ecodesign and Energy LabellingDirectives 40

Contents

2 15032016 - 300026080-001-07

3 15032016 - 300026080-001-07

1 Safety instructions

11 General safety instructions

DANGER

This appliance can be used by children agedfrom 8 years and above and persons withreduced physical sensory or mental capabilitiesor lack of experience and knowledge if they havebeen given supervision or instruction concerninguse of the appliance in a safe way andunderstand the hazards involved Children shallnot play with the appliance Cleaning and usermaintenance shall not be made by childrenwithout supervision

CAUTION

4 The use of the boiler and system by you asthe end-user must be limited to theoperations described in this User ManualAll other actions may only be undertaken bya qualified fitterengineer

4 Only qualified persons are authorised toassemble install and maintain theinstallation

DANGER

If you smell gas1 Do not use a naked flame do not smoke do

not operate electrical contacts or switches( doorbell light motor lift etc)

2 Shut off the gas supply3 Open the windows4 Evacuate the premises5 Call your fitter

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 4

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 2: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Contents

1 Safety instructions 411 General safety instructions 4

12 Recommendations 5

13 Liabilities 6131 Manufacturerrsquos liability 6132 Installerrsquos liability 7133 Userrsquos liability 7

2 About this manual 821 Symbols used 8

211 Symbols used in the manual 8212 Symbols used on the equipment 8

22 Abbreviations 9

3 Technical specifications 1031 Certifications 10

32 Technical specifications 10

4 Description 1241 Operating principle 12

411 Gasair setting 12412 Combustion 12

42 Main parts 13

43 Control panel 14431 Description of the keys 14432 Description of the display 15433 Browsing in the menus 17

5 Operating the appliance 1951 Putting the appliance into operation 19

52 Reading out measured values 19

53 Changing the settings 21531 Setting the set point temperatures 21532 Selecting the operating mode 21533 Forcing domestic hot water production 22534 Setting the contrast and lighting on the

display 23

1 15032016 - 300026080-001-07

535 Setting the time and date 23536 Selecting a timer programme 24537 Customising a timer programme 24

54 Installation shutdown 26

55 Antifreeze protection 26

6 Checking and maintenance 2861 General instructions 28

62 Periodic checks 28

7 Troubleshooting 3071 Anti-hunting 30

72 Messages (Code type Bxx or Mxx) 30

73 Faults (Code type Lxx or Dxx) 32

8 Energy savings 3881 Energy-saving advice 38

82 Recommendations 38

9 Warranty 3991 General 39

92 Warranty terms 39

10 Appendix ndash Information on the Ecodesign and Energy LabellingDirectives 40

Contents

2 15032016 - 300026080-001-07

3 15032016 - 300026080-001-07

1 Safety instructions

11 General safety instructions

DANGER

This appliance can be used by children agedfrom 8 years and above and persons withreduced physical sensory or mental capabilitiesor lack of experience and knowledge if they havebeen given supervision or instruction concerninguse of the appliance in a safe way andunderstand the hazards involved Children shallnot play with the appliance Cleaning and usermaintenance shall not be made by childrenwithout supervision

CAUTION

4 The use of the boiler and system by you asthe end-user must be limited to theoperations described in this User ManualAll other actions may only be undertaken bya qualified fitterengineer

4 Only qualified persons are authorised toassemble install and maintain theinstallation

DANGER

If you smell gas1 Do not use a naked flame do not smoke do

not operate electrical contacts or switches( doorbell light motor lift etc)

2 Shut off the gas supply3 Open the windows4 Evacuate the premises5 Call your fitter

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 4

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 3: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

535 Setting the time and date 23536 Selecting a timer programme 24537 Customising a timer programme 24

54 Installation shutdown 26

55 Antifreeze protection 26

6 Checking and maintenance 2861 General instructions 28

62 Periodic checks 28

7 Troubleshooting 3071 Anti-hunting 30

72 Messages (Code type Bxx or Mxx) 30

73 Faults (Code type Lxx or Dxx) 32

8 Energy savings 3881 Energy-saving advice 38

82 Recommendations 38

9 Warranty 3991 General 39

92 Warranty terms 39

10 Appendix ndash Information on the Ecodesign and Energy LabellingDirectives 40

Contents

2 15032016 - 300026080-001-07

3 15032016 - 300026080-001-07

1 Safety instructions

11 General safety instructions

DANGER

This appliance can be used by children agedfrom 8 years and above and persons withreduced physical sensory or mental capabilitiesor lack of experience and knowledge if they havebeen given supervision or instruction concerninguse of the appliance in a safe way andunderstand the hazards involved Children shallnot play with the appliance Cleaning and usermaintenance shall not be made by childrenwithout supervision

CAUTION

4 The use of the boiler and system by you asthe end-user must be limited to theoperations described in this User ManualAll other actions may only be undertaken bya qualified fitterengineer

4 Only qualified persons are authorised toassemble install and maintain theinstallation

DANGER

If you smell gas1 Do not use a naked flame do not smoke do

not operate electrical contacts or switches( doorbell light motor lift etc)

2 Shut off the gas supply3 Open the windows4 Evacuate the premises5 Call your fitter

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 4

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 4: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

3 15032016 - 300026080-001-07

1 Safety instructions

11 General safety instructions

DANGER

This appliance can be used by children agedfrom 8 years and above and persons withreduced physical sensory or mental capabilitiesor lack of experience and knowledge if they havebeen given supervision or instruction concerninguse of the appliance in a safe way andunderstand the hazards involved Children shallnot play with the appliance Cleaning and usermaintenance shall not be made by childrenwithout supervision

CAUTION

4 The use of the boiler and system by you asthe end-user must be limited to theoperations described in this User ManualAll other actions may only be undertaken bya qualified fitterengineer

4 Only qualified persons are authorised toassemble install and maintain theinstallation

DANGER

If you smell gas1 Do not use a naked flame do not smoke do

not operate electrical contacts or switches( doorbell light motor lift etc)

2 Shut off the gas supply3 Open the windows4 Evacuate the premises5 Call your fitter

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 4

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 5: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

1 Safety instructions

11 General safety instructions

DANGER

This appliance can be used by children agedfrom 8 years and above and persons withreduced physical sensory or mental capabilitiesor lack of experience and knowledge if they havebeen given supervision or instruction concerninguse of the appliance in a safe way andunderstand the hazards involved Children shallnot play with the appliance Cleaning and usermaintenance shall not be made by childrenwithout supervision

CAUTION

4 The use of the boiler and system by you asthe end-user must be limited to theoperations described in this User ManualAll other actions may only be undertaken bya qualified fitterengineer

4 Only qualified persons are authorised toassemble install and maintain theinstallation

DANGER

If you smell gas1 Do not use a naked flame do not smoke do

not operate electrical contacts or switches( doorbell light motor lift etc)

2 Shut off the gas supply3 Open the windows4 Evacuate the premises5 Call your fitter

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 4

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 6: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

DANGER

If you smell flue gases1 Switch the appliance off2 Open the windows3 Evacuate the premises4 Call your fitter

DANGER

The installation and maintenance of the boilermust be undertaken by a qualified fitterengineerin accordance with the information in thesupplied Installation and Service Manual doingotherwise may result in dangerous situationsandor bodily injury

WARNING

Depending on the settings of the appliance4 The temperature of the flue gas conduits

may exceed 60degC4 The temperature of the radiators may reach

85degC4 The temperature of the domestic hot water

may reach 65degC

CAUTION

Do not neglect to service the appliance4 For completely safe and optimum operation

you must have your boiler regularly servicedby an approved installer

12 Recommendations

WARNING

Only qualified professionals are authorised towork on the appliance and the installation

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

5 15032016 - 300026080-001-07

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 7: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

DANGER

For safety reasons we recommended fittingsmoke and CO alarms at suitable places in yourhome

4Regularly check the water pressure in the installation(minimum pressure 08 bar recommended pressurebetween 08 and 15 bar)

4Keep the appliance accessible at all times4Never remove or cover labels and rating plates affixed

to the appliance Labels and rating plates must belegible throughout the entire lifetime of the appliance

4The appliance should be on Summer or Antrifreezemode rather than switched off to guarantee thefollowing functions- Anti blocking of pumps- Antifreeze protection

13 Liabilities

131 Manufacturerrsquos liability

Our products are manufactured in compliance with therequirements of the various applicable European

Directives They are therefore delivered with [ markingand all relevant documentationIn the interest of customers we are continuouslyendeavouring to make improvements in product qualityAll the specifications stated in this document are thereforesubject to change without notice

Our liability as the manufacturer may not be invoked in thefollowing cases4Failure to abide by the instructions on using the

appliance4Faulty or insufficient maintenance of the appliance4Failure to abide by the instructions on installing the

appliance

AGC 1015 AGC 15 AGC 25 AGC 35 1 Safety instructions

15032016 - 300026080-001-07 6

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 8: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

132 Installerrsquos liability

The installer is responsible for the installation andcommissioning of the appliance The installer mustrespect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Carry out installation in compliance with the prevailing

legislation and standards4Perform the initial start up and carry out any checks

necessary4Explain the installation to the user4 If a maintenance is necessary warn the user of the

obligation to check the appliance and maintain it ingood working order

4Give all the instruction manuals to the user

133 Userrsquos liability

To guarantee optimum operation of the appliance theuser must respect the following instructions4Read and follow the instructions given in the manuals

provided with the appliance4Call on qualified professionals to carry out installation

and initial start up4Get your installer to explain your installation to you4Ensure the Appliance is serviced in accordance with

the manufacturerrsquos instructions by a suitable qualifiedperson

4Keep the instruction manuals in good condition closeto the appliance

1 Safety instructions AGC 1015 AGC 15 AGC 25 AGC 35

7 15032016 - 300026080-001-07

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 9: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

2 About this manual

21 Symbols used

211 Symbols used in the manual

In these instructions various danger levels are employed to draw theuserrsquos attention to particular information In so doing we wish tosafeguard the userrsquos safety highlight hazards and guarantee correctoperation of the appliance

DANGER

Risk of a dangerous situation causing serious physicalinjury

WARNING

Risk of a dangerous situation causing slight physicalinjury

CAUTION

Risk of material damage

Signals important information

frac14Signals a referral to other instructions or other pages in theinstructions

212 Symbols used on the equipment

4 Protective earthing~ Alternating current

Before installing and commissioning the device readcarefully the instruction manuals provided

Dispose of the used products in an appropriate recoveryand recycling structure

This appliance must be connected to the protective earth

D000241-C

AGC 1015 AGC 15 AGC 25 AGC 35 2 About this manual

15032016 - 300026080-001-07 8

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 10: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Caution danger live partsDisconnect the mains power prior to any operations

22 Abbreviations

4 3CE Collective conduit for sealed boiler4 DHW Domestic hot water4 Interscenario switch Home automation switch that can be used

to centralise and control several scenarios4 Hi Lower heating value LHV (Nett)4 Hs Higher heating value HHV (Gross)4 PPS Polypropylene hardly inflammable4 PCU Primary Control Unit - PCB for managing burner operation4 PSU Parameter Storage Unit - Parameter storage for PCBs

PCU and SU4 SCU Secondary Control Unit - control panel PCB4 SU Safety Unit - Safety PCB4 3WV 3-way valve4 HL High Load - DHW tank with plate exchanger4 SL Standard Load - DHW tank with coil4 SHL Solar High Load - Solar DHW tank with plate exchanger4 SSL Solar Standard Load - Solar DHW tank with coil

1 2

M002628-A

2 About this manual AGC 1015 AGC 15 AGC 25 AGC 35

9 15032016 - 300026080-001-07

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 11: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

3 Technical specifications

31 Certifications

CE identification no CE-0085CM0178NOx classification 5 (EN 15502-1 EN 15502-2-1)Type of connection Chimney B23 B33

Flue gas outlet C13(x) C33(x) C43(x) C53 C83(x)C93(x)

32 Technical specifications

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35GeneralNominal output (Pn)Heating System (8060 degC)

minimum-maximum

kW 30 - 104 30 - 149 50 - 248 63 - 348

Nominal output (Pn)Heating System (5030 degC)

minimum-maximum

kW 34 - 112 34 - 158 56 - 255 70 - 359

Nominal output (Pn)Heating System (4030 degC)

minimum-maximum

kW 34 - 160 34 - 160 56 - 259 70 - 364

Nominal input (Qn)Heating System (Hi)

minimum-maximum

kW 31 - 105 31 - 150 52 - 250 65 - 351

Nominal input(Qn)Heating System (Hs)

minimum-maximum

kW 34 - 117 34 - 167 58 - 278 72 - 390

Nominal input (Qnw)DHW System (Hi)

minimum-maximum

kW 31 - 150 31 - 150 52 - 293 65 - 351

Nominal input (Qnw)DHW System (Hs)

minimum-maximum

kW 34 - 167 34 - 167 58 - 326 72 - 390

Heating efficiency under full load (Hi)(8060 degC)

- 993 993 992 991

Heating efficiency under full load (Hi)(5030 degC)

- 1070 1053 1020 1022

Heating efficiency under partial load(Hi) (Return temperature 60degC)

- 949 949 961 963

Heating efficiency under partial load(EN 9242) (Return temperature30degC)

- 1102 1102 1101 1106

Data on the gases and combustion gasesGas consumption - Natural gas H(G20)

minimum-maximum

m3h 033 - 159 033 - 159 055 - 310 069 - 371

Gas consumption - Natural gas L(G25)

minimum-maximum

m3h 038 - 185 038 - 185 064 - 361 080 - 432

Gas consumption - Propane G31 minimum-maximum

m3h 013 - 061 013 - 061 021 - 120 027 - 144

Mass flue gas flow rate minimum-maximum

kgh 53 - 252 53 - 252 89 - 493 111 - 573

AGC 1015 AGC 15 AGC 25 AGC 35 3 Technical specifications

15032016 - 300026080-001-07 10

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 12: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Boiler type AGC 1015 AGC 15 AGC 25 AGC 35Flue gas temperature minimum-

maximumdegC 30 - 65 30 - 65 30 - 80 30 - 75

Maximum counter pressure Pa 80 80 130 140Characteristics of the heating circuitWater content (ex expansion vessel) l 19 19 19 25Water operating pressure minimum kPa (bar (MPa)) 80 (08) 80 (08) 80 (08) 80 (08)Water operating pressure (PMS) maximum kPa (bar (MPa)) 300 (30) 300 (30) 300 (30) 300 (30)Water temperature maximum degC 110 110 110 110Operating temperature maximum degC 90 90 90 90Electrical characteristicsPower supply voltage VAC 230 230 230 230Power consumption - Full load maximum W 101 101 116 132Electrical protection index IP21 IP21 IP21 IP21Other characteristicsWeight (empty) kg 56 56 56 50

3 Technical specifications AGC 1015 AGC 15 AGC 25 AGC 35

11 15032016 - 300026080-001-07

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 13: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

4 Description

41 Operating principle

411 Gasair setting

Air is sucked in by the fan and the gas injected into the venturiattached to the fan inlet The fan rotation speed modulates and adaptsto thermal energy requirements thanks to the temperatures measuredby the various sensors The gas and air are mixed in the venturi whichenables operation at a constant ratio The noise of the venturi isabsorbed by a silencer attached to its inlet The gasair mixture iscarried to the burner in the top of the exchanger guided by the pre-mix channel

412 Combustion

The burner heats the heating water circulating in the heatexchanger At a return temperature lower than around 55degC the fluegases cool down to a temperature lower than the dew point thuscausing the condensation of the water vapour contained in the fluegases in the lower section of the heat exchanger The heat releasedduring this condensation process (the latent heat or condensing heat)is also transferred to the heating water The cooled combustion gasesare evacuated via the combustion gas outlet flue The condensationwater is evacuated via a condensate trap

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 12

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 14: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

42 Main parts

1 Flue gas discharge pipe2 Flue gas measuring point3 Heat exchanger4 Ignitionionization electrode5 Box for the control PCBs6 Control panel7 Command module8 Water pressure sensor9 Circulation pump10 Hydroblock11 3-way valve12 Safety valve13 Casing14 Expansion vessel15 Combined venturi and gas valve unit16 Fan17 Air intake silencer18 Mixer pipe19 Automatic air vent

C003072-C

18

19

16

17

15

14

13

12

11

1234

10

9

5

6

7

8

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

13 15032016 - 300026080-001-07

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 15: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

43 Control panel

431 Description of the keys

A Temperature setting key (heating DHW swimming pool)B Operating mode selection keyC DHW override keyD Key to access the parameters reserved for the installerE Keys on which the function varies as and when selections

are madeF Rotary setting button

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

A0

00

86

6-A

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

A

B

C

D E F

(

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 14

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 16: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

432 Description of the display

n Key functions

gt Access to the various menus

( Used to scroll through the menus

rsquo Used to scroll through the parameters The symbol is displayed when help is available

f Used to display the curve of the parameter selectedSTD Reset of the time programmes

b Selection of comfort mode or selection of the days to beprogrammed

v Selection of reduced mode or deselection of the days tobe programmed

j Back to the previous levelESC Back to the previous level without saving the

modifications made

t Manual reset

n Flame output level

C002705-A

The whole symbol flashes The burner starts up but theflame is not yet present

C002704-A

Part of the symbol flashes Output is increasing

C002703-A

Steady symbol The required output has been reached

C002702-A

Part of the symbol flashes Output is dropping

bar

r

STD( t

0 2 4 6 8 10 12 14 16 18 22 2420

C002696-A

pb AUTOx c rjLg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002701-B

pb AUTOx c rjMg m

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

15 15032016 - 300026080-001-07

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 17: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

n Solar (If connected)

u The solar load pump is running

L000200-A The top part of the tank is reheated to the tank set point

L000201-A The entire tank is reheated to the tank set point

L000198-A The entire tank is reheated to the solar tank set point

L000199-A The tank is not loaded - Presence of the solar control

system

n Operating modes

p Summer mode The heating is off Domestic hot watercontinues to be produced

b WINTER mode Heating and domestic hot water working

AUTO Operation in automatic mode according to the timerprogramme

x Comfort mode The symbol is displayed when a DAYoverride (comfort) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

m Reduced mode The symbol is displayed when a NIGHToverride (reduced) is activated

4 Flashing symbol Temporary override4 Steady symbol Permanent override

g Holiday mode The symbol is displayed when a HOLIDAYoverride (antifreeze) is activated

4 Flashing symbol Holiday mode programmed4 Steady symbol Holiday mode active

m Manual mode The boiler operates with the displayed setpoint All of the pumps operate The 3-way valves are notcontrolled

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

L000197-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002697-B

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002698-B

pb AUTOx c rjMg m

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 16

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 18: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

n System pressure

bar Pressure indicator The symbol is displayed when a waterpressure sensor is connected

4 Flashing symbol The water pressure is insufficient4 Steady symbol The water pressure is sufficient

l Water pressure level

4 R 09 to 11 bar4 E 12 to 15 bar4 Z 16 to 19 bar4 A 20 to 23 bar4 l gt 24 bar

n Domestic Hot Water override

A bar is displayed when a DHW override is activated

4 Flashing bar Temporary override4 Steady bar Permanent override

n Other information

433 Browsing in the menus

1 To select the desired menu turn the rotary button2 To access the menu press the rotary button

To go back to the previous display press the key j

3 To select the desired parameter turn the rotary button4 To modify the parameter press the rotary button

To go back to the previous display press the key j

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002708-A

pb AUTOx c rjMg m

bar

STD t

0 2 4 6 8 10 12 14 16 18 22 2420

C002707-A

pb AUTOx c rjMg m

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

MEASURES

CHOICE TIME PROG

TIME PROGRAM

SETTING

TIME DAYa

C002220-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGB

CURRENT PROGC

P2

P3

a

C002221-C-04

4 Description AGC 1015 AGC 15 AGC 25 AGC 35

17 15032016 - 300026080-001-07

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 19: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

5 To modify the parameter turn the rotary button6 To confirm press the rotary button

To cancel press key h

7 To go back to the main display press key j2 times

It is possible to use the ( and rsquo keys instead of the rotarybutton

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

CURRENT PROGCChoice of the timeprogram applied C

P4

a

C002222-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

LUNDI 1145

C002224-D-04

2x

AGC 1015 AGC 15 AGC 25 AGC 35 4 Description

15032016 - 300026080-001-07 18

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 20: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

5 Operating the appliance

51 Putting the appliance into operation

1 Turn on the boiler using the onoff switch

2 The first time the boiler is powered up the LANGUAGE menu isdisplayed Select the desired language by turning the rotarybutton

3 To confirm press the rotary buttonThe boiler will begin an automatic venting-programme (which lastsapprox 3 minutes) and will do this every time the power supply isisolated If there is a problem the error is displayed on the screen

4 Check the water pressure in the installation shown on the controlpanel display

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

52 Reading out measured values

The various values measured by the appliance are displayed in theMEASURES menu

1 To access user level Press the gt key2 Select the menu MEASURES

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

8 22 2420

l

0

C003159-B

Franccedilais - Deutsch - English - Italiano - Espanol - Nederlands- Pycck - Polski - Tuumlrk -

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb x c rg m

yumlLANGUE FRANCAIS

C002286-C

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

19 15032016 - 300026080-001-07

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 21: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

User level - MEASURES Menu

Parameter Description UnitOUTSIDE TEMP Outside temperature degCROOMTEMPA (1) Room temperature of circuit A degC

ROOMTEMPB (1) Room temperature of circuit B degC

ROOMTEMPC (1) Room temperature of circuit C degCBOILER TEMP Water temperature in the boiler degCPRESSURE Water pressure in the installation bar (MPa)WATER TEMP (1) Water temperature in the DHW tank degC

TEMP DHW INST (1) Instant hot water temperature degCSTORTANKTEMP(1)

Water temperature in the storage tank degC

SWIMMING PTB (1) Water temperature of the swimming pool on circuit B degC

SWIMMING PTC (1) Water temperature of the swimming pool on circuit C degC

OUTLET TEMPB (1) Temperature of the flow water in circuit B degC

OUTLET TEMPC (1) Temperature of the flow water in circuit C degC

TEMPSYSTEM (1) Temperature of the system flow water if multi-generator degC

TDHW BOTTOM (1) Water temperature in the bottom of the DHW tank degC

TEMPTANK AUX (1) Water temperature in the second DHW tank connected to the AUX circuit degC

DHW A TEMP (1) Water temperature in the second DHW tank connected to circuit A degC

TEMPSOLTANK (1) Temperature of the hot water produced by solar power (TS) degC

SOLARCOLLT (1) Solar panel temperature (TC) degC

SOLAENERGY (1) Solar energy accumulated in the tank kWhBACK TEMP Temperature of the boiler return water degCFAN SPEED Fan rotation speed rpmPOWER Instantaneous boiler output (0 Burner off or running at minimum output) CURRENT (microA) Ionization current microAHEATCONS (2) Energy consumed by the boiler in heating mode (estimated value) kWh

DHW CONS (2) Energy consumed by the boiler in DHW mode (estimated value) kWhNB IMPULS Number of burner starts (not restartable)

The meter is incremented by 8 every 8 start-ups

RUNTIME Number of burner operation hours (not restartable)The meter is incremented by 2 every 2 hours

h

IN 0-10V (1) Voltage at input 0-10 V VSEQUENCE Control system sequence CTRL Software control number (1) The parameter is only displayed for the options circuits or sensors actually connected(2) The parameter is only displayed if the function is activated (parameter ENERGY METER in the CONFIGURATION menu)

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 20

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 22: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

53 Changing the settings

531 Setting the set point temperatures

C Menu

Parameter Adjustment range Description Factory settingDAY TEMPA 5 to 30 degC Desired room temperature in comfort periods on circuit A 20 degCNIGHT TEMPA 5 to 30 degC Desired room temperature in reduced periods on circuit A 16 degCDAY TEMPB (1) 5 to 30 degC Desired room temperature in comfort periods on circuit B 20 degCNIGHT TEMPB (1) 5 to 30 degC Desired room temperature in reduced periods on circuit B 16 degCDAY TEMPC (1) 5 to 30 degC Desired room temperature in comfort periods on circuit C 20 degCNIGHT TEMPC (1) 5 to 30 degC Desired room temperature in reduced periods on circuit C 16 degCDHW TEMP (1) 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 55 degCTEMPTANK AUX (1) 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 55 degCDHW A TEMP (1) 10 to 90 degC Desired domestic hot water temperature in circuit A 55 degCTEMPSOLTANK (1)

(2) 20 to 80 degC Maximum load temperature of the tankrsquos solar zone 65 degC

SWIMMING PTB (1) HG 05 to 39 degC Desired temperature for swimming pool B 20 degCSWIMMING PTC (1) HG 05 to 39 degC Desired temperature for swimming pool C 20 degCWATER TNIGHT 10 to 80 degC Desired domestic hot water temperature in the DHW circuit 10 degCWATER TNIGHTAUX 10 to 90 degC Desired domestic hot water temperature in the auxiliary circuit 10 degCWATER TNIGHTA 10 to 90 degC Desired domestic hot water temperature in circuit A 10 degC(1) The parameter is only displayed for the options circuits or sensors actually connected(2) The menu is only displayed if the solar control system is connected

532 Selecting the operating mode

To select an operating mode proceed as follows

1 Press the MODE key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

MODE

C002267-A

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

21 15032016 - 300026080-001-07

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 23: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

MODE MenuParameter Adjustment range Description Factory settingAUTOMATIQUE The comfort ranges are determined by the timer programmeDAY 77 xxxx Comfort mode is forced until the time indicated or all the time (77) Present time + 1

hourNIGHT 77 xxxx Reduced mode is forced until the time indicated or all the time

(77)Present time + 1hour

HOLIDAYS 77 1 to 364 The antifreeze mode is active on all boiler circuitsNumber of daysrsquo holiday xx (1)

heating OFF xxxx (1)

Restarting xxxx (1)

Present date + 1day

SUMMER The heating is offDomestic hot water continues to be produced

MANUEL The generator operates according to the set point setting All ofthe pumps operate Option of setting the set point by simplyturning the rotary button

FORCE AUTO (2) YES NO An operating mode override is activated on the remote control(option)To force all circuits to run on AUTOMATIQUE mode selectYES

(1) The start and end days and the number of days are calculated in relation to each other(2) The parameter is only displayed if a room sensor is connected

533 Forcing domestic hot water production

To force domestic hot water production proceed as follows

1 Press the r key2 To select the desired parameter turn the rotary button3 To modify the parameter press the rotary button

To go back to the previous display press the key j4 To modify the parameter turn the rotary button5 To confirm press the rotary button

To cancel press key h

r MenuParameter Description Factory settingAUTOMATIQUE The domestic hot water comfort ranges are determined by the timer programme COMFORT Domestic hot water comfort mode is forced until the time indicated or all the time (77) Present time + 1 hour

MODE

C002268-A

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 22

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 24: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

534 Setting the contrast and lighting on thedisplay

1 To access user level Press the gt key2 Select the menu SETTING

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - SETTING Menu

Parameter Adjustment range Description Factory setting Customer settingCONTRAST DISP Adjusting the display contrast BACK LIGHT COMFORT The screen is illuminated continuously in

daytime periodsECO

ECO The screen is illuminated for 2 minuteswhenever pressed

535 Setting the time and date

1 To access user level Press the gt key2 Select the menu TIME DAY

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 Set the following parameters

User level - TIME DAY Menu (1)

Parameter Adjustment range Description Factory setting Customer settingHOURS 0 to 23 Hours setting MINUTE 0 to 59 Minutes setting DAY Monday to Sunday Setting the day of the week DATE 1 to 31 Day setting MONTH January to December Month setting YEAR 2008 to 2099 Year setting SUMTIME AUTO automatic switch to summer time on the last Sunday

in March and back to winter time on the last Sundayin October

AUTO

MANU for countries where the time change is done on otherdates or is not in use

(1) According to the configuration

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

23 15032016 - 300026080-001-07

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 25: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

536 Selecting a timer programme

1 To access user level Press the gt key2 Select the menu CHOICE TIME PROG

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter4 Assign the desired timer programme (P1 to P4) to the circuit with

the rotary button

User level - CHOICE TIME PROG Menu

Parameter Adjustment range DescriptionCURRENT PROGA P1 P2 P3 P4 Comfort programme activated

(Circuit A)CURRENT PROGB P1 P2 P3 P4 Comfort programme activated

(Circuit B)CURRENT PROGC P1 P2 P3 P4 Comfort programme activated

(Circuit C)

537 Customising a timer programme

1 To access user level Press the gt key2 Select the menu TIME PROGRAM

4 Turn the rotary button to scroll through the menus ormodify a value

4 Press the rotary button to access the selected menuor confirm a value modification

frac14For a detailed explanation of menu browsing refer tothe chapter Browsing in the menus page 17

3 To select the desired parameter

User level - TIME PROGRAM Menu

Parameter Time schedule DescriptionTIME PROGA PROG P2 A

PROG P3 APROG P4 A

Timer programme for circuit A

TIME PROGB PROG P2 BPROG P3 BPROG P4 B

Timer programme for circuit B

TIME PROGC PROG P2 CPROG P3 CPROG P4 C

Timer programme for circuit C

TIME PROGDHW DHW circuit timer programmeTIME PROGAUX Auxiliary circuit timer programme

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

C002219-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 24

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 26: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

4 To select a timer programme to be modified5 To select to days for which the timer programme is to be

modifiedTurn the rotary button to the left until you reach the day desiredTo confirm press the rotary button

6 b Day selectionPress key b v until the symbol b is displayedTurn the rotary button to the right to select the day(s) desiredv Cancelling the day selectionPress key b v until the symbol v is displayedTurn the rotary button to the right to cancel selection of the relevantday(s)

7 When the days desired for the programme have been selectedpress the rotary button to confirm

8 To define the timer ranges for the comfort mode and reducedmodeTurn the rotary button to the left until 000 is displayed The firstsegment of the graphic bar for the timer programme flashes

9 b Comfort mode selectionPress key b v until the symbol b is displayedTo select a comfort time range turn the rotary button to the rightv Reduced mode selectionPress key b v until the symbol v is displayedTo select a reduced time range turn the rotary button to the right

10When the times for the comfort mode have been selected pressthe rotary button to confirm

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGA Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuDisplay of the timeprogram To continuepush on the button a

C002228-B-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSelect the days toprogram a

C002229-C-04

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjLg m

PROG P2 C Mo Tu We Th Fr Sa SuSet the time program a

C002230-E-04

0600

0600

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

25 15032016 - 300026080-001-07

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 27: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

User level - TIME PROGRAM Menu

Day Comfort periods Filling enabledP1_______________

P2 _______________ P3 _______________ P4 _______________

TIME PROGB Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGC Monday 600 to 2200 Tuesday 600 to 2200 Wednesday 600 to 2200 Thursday 600 to 2200 Friday 600 to 2200 Saturday 600 to 2200 Sunday 600 to 2200

TIME PROGDHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday

TIME PROGAUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday

54 Installation shutdown

CAUTION

Do not switch off the mains supply to the appliance If thecentral heating system is not used for a long period werecommend activating the HOLIDAYS mode (to ensurethe anti-grip of the heating pump)

55 Antifreeze protection

When the heating water temperature in the boiler is too low theintegrated boiler protection system starts up This protection functionsas follows

4 If the water temperature is lower than 7degC the heating pump startsup

AGC 1015 AGC 15 AGC 25 AGC 35 5 Operating the appliance

15032016 - 300026080-001-07 26

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 28: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

4 If the water temperature is lower than 4degC the boiler starts up4 If the water temperature is higher than 10degC the boiler shuts down

and the circulation pump continues to run for a short time4 If the water temperature in the storage tank is less than 4degC it is

reheated to its set point

CAUTION

4 The antifreeze protection does not function if theappliance is switched off

4 The integrated protection system only protects theboiler not the installation To protect the installationset the appliance to HOLIDAYS mode

The HOLIDAYS mode protects

4 The installation if the outside temperature is lower than 3degC(factory setting)

4 The room temperature if a remote control is connected and theroom temperature is lower than 6 degC (factory setting)

4 The domestic hot water tank if the tank temperature is lowerthan 4 degC (the water is reheated to 10 degC)

To configure the holidays mode frac14See chapter Selecting theoperating mode page 21

5 Operating the appliance AGC 1015 AGC 15 AGC 25 AGC 35

27 15032016 - 300026080-001-07

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 29: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

6 Checking and maintenance

61 General instructions

The boiler does not require a lot of maintenance Nevertheless werecommend having the boiler inspected and serviced at regularintervals

4 Maintenance and cleaning of the boiler must be carried out at leastonce a year by a qualified technician

4 Have the flues swept at least once a year or more depending onthe regulations in force in your country

CAUTION

4 Maintenance operations must be done by a qualifiedengineer

4 We recommend taking out a maintenance contract4 Only original spare parts must be used4 Make certain that the flues and chimneys are

connected in good condition and not blocked4 Do not modify nor block the condensate outlet(s)4 If a neutralisation system is installed follow the

instructions delivered with the neutralisation systemfor cleaning and servicing of this system

The boiler displays a message whenever maintenance is necessary

1 When the message REVISION is displayed press to displaythe installerrsquos telephone number (only if the installer has input thisparameter)

2 Contact the fitter3 Ensure the Appliance is serviced in accordance with the

manufacturerrsquos instructions by a suitable qualified person

62 Periodic checks

4 Check the water pressure in the installation (MEASURE mode)

If the water pressure is lower than 08 bar more watershould be added If necessary top up the water level in theheating system (recommended hydraulic pressurebetween 15 and 20 bar)

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

AGC 1015 AGC 15 AGC 25 AGC 35 6 Checking and maintenance

15032016 - 300026080-001-07 28

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 30: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

4 Carry out a visual check for the presence of any water leaks

4 Open and close the radiator valves several times a year (thisprevents the valves from seizing up)

4 Clean the outside of the boiler using a damp cloth and a lightdetergent

CAUTION

Only a qualified professional is authorised to clean theinside of the boiler

T001507-B

1

2

3

4

T000181-B

6 Checking and maintenance AGC 1015 AGC 15 AGC 25 AGC 35

29 15032016 - 300026080-001-07

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 31: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

7 Troubleshooting

71 Anti-hunting

When the boiler is in Anti-short-cycle operating mode the symbol flashes

1 Press the keyThe message Operation assured when the restart temperaturewill be reached is displayed

This message is not an error message but an item ofinformation

72 Messages (Code type Bxx or Mxx)

In the case of failure the control panel displays a message and acorresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Switch the boiler off and switch back onThe boiler starts up again automatically when the reason for theblocking has been removed

3 If the code is displayed again correct the problem by following theinstructions in the table below

Code Messages Description Checking solutionB00 BLPSU ERROR The PSU PCB is incorrectly

configuredParameter error on the PSU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B01 BLBOILER MAX Maximum flow temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)B02 BLHEATING SPEED The increase in flow temperature

has exceeded its maximum limitThe water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

B07 BLDT OUTL RET Maximum difference betweenthe flow and return temperatureexceeded

The water flow in the installation is insufficient

4 Check the circulation (direction pump valves)4 Check the water pressureSensor error

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 30

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 32: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Messages Description Checking solutionB08 BLRL OPEN The RL inlet on the PCU PCB

terminal block is openParameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B09 BLINVLN 4 Contact the professional who takes care of maintenance of the applianceB10B11

BLSCINOPEN The BL inlet on the PCU PCBterminal block is open

The contact connected to the BL inlet is open

4 Contact the professional who takes care ofmaintenance of the appliance

Parameter error

4 Contact the professional who takes care ofmaintenance of the appliance

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B13 BL PCU COM Communication error with theSCU PCB

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

SCU PCB not installed in the boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B14 BLWATER MIS The water pressure is lower than08 bar

Not enough water in the circuit

4 Top up the installation with waterB15 BLGAS PRESS Gas pressure too low Incorrect setting of the gas pressure switch on the SCU

PCB

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB16 BLBAD SU The SU PCB is not recognised Wrong SU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B17 BLBAD PSU The parameters saved on thePCU PCB are impaired

Parameter error on the PCU PCB

4 Contact the professional who takes care ofmaintenance of the appliance

B18 BLBAD PSU The PSU PCB is not recognised Wrong PSU PCB for this boiler

4 Contact the professional who takes care ofmaintenance of the appliance

B19 BLNO CONFIG The boiler has not beenconfigured

The PSU PCB has been changed

4 Contact the professional who takes care ofmaintenance of the appliance

B21 BLCOM SU Communication error betweenthe PCU and SU PCBs

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

B22 BLFLAME LOS No flame during operation No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceB25 BLSU ERROR Internal error on the SU PCB 4 Contact the professional who takes care of

maintenance of the applianceB26 BLDHW S The DHW tank sensor is

disconnected or short circuited4 Contact the professional who takes care of

maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

31 15032016 - 300026080-001-07

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 33: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Messages Description Checking solutionB27 BLDHW INST The sensor on the plate

exchanger outlet is disconnectedor short circuited

4 Contact the professional who takes care ofmaintenance of the appliance

B28 BLBADCONFIG An HL tank is detected whilst theboiler cannot control itThis message disappears after10 seconds if the boiler cancontrol the HL tank

4 Wait for 10 seconds to see whether the error persists4 Contact the professional who takes care of

maintenance of the appliance

B29 toB34

BLUNKNOWN Bxx Incorrect configuration of thePCU

4 Contact the professional who takes care ofmaintenance of the appliance

M04 REVISION A service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M05 REVISION A An A B or C service is required The date programmed for the service has been reached

4 If the symbol flashes press key The installerrsquoscontact details are displayed

4 Contact the professional who takes care ofmaintenance of the appliance

M06 REVISION BM07 REVISION C

M20 DISGAS A boiler vent cycle is underway Switching the boiler on

4 Wait 3 minutes FLDRYB XX DAYS Floor drying is active

XX DAYS = Number of daysrsquofloor drying remaining

Floor drying is underway Heating on the circuits notconcerned is shut down

4 Contact the professional who takes care ofmaintenance of the appliance

FLDRYC XX DAYSFLDRYB+C XXDAYS

M23 CHANGE OUTSIS The outside temperature sensoris defective

Change the outside radio temperature sensor

M30 BLSYSTEMNETWORK

No communication with themaster regulation through theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

M31 BLCOM MODBUS Incorrect configuration of theMODBUS network

4 Contact the professional who takes care ofmaintenance of the appliance

73 Faults (Code type Lxx or Dxx)

In the event of operational failure the control panel flashes anddisplays an error message and a corresponding code

1 Make a note of the code displayedThe code is important for the correct and rapid diagnosis of thetype of failure and for any technical assistance that may beneeded

2 Press the t key If the code is displayed again switch off the boilerand then switch it back on

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COM FAIL D27

C002604-B-04

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 32

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 34: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

3 Press the key Follow the instructions displayed to solve theproblem

4 Consult the meaning of the codes in the table below

Code Faults Causeof thefault

Description Checking solution

L00 PSU FAIL PCU PSU PCB not connected Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L01 PSU PARAM FAIL PCU The safety parameters are incorrect Bad connectionPSU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L02 DEFOUTLET S PCU The boiler flow sensor has short-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L03 DEFOUTLET S PCU The boiler flow sensor is on an opencircuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L04 DEFOUTLET S PCU Boiler temp too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L05 STB OUTLET PCU Boiler temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L06 BACK SFAILURE PCU The return temperature sensor hasshort-circuited

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

bar

1

1

2

2

rc

STD( t

v

0 2 4 6 8 10 12 14 16 18 22 2420

pb AUTOx c rjMg m

SUNDAY 1145

TEMP 68deg

PCU COMFAIL D27

C002302-D-04

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

33 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 35: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Faults Causeof thefault

Description Checking solution

L07 BACK SFAILURE PCU The return temperature sensor is onan open circuit

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

L08 BACK SFAILURE PCU Return temperature too low Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L09 STB BACK PCU Return temperature too high Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L10 DT RET-DEPgtMAX PCU Difference between the flow andreturn temperatures insufficient

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L11 DEP-RETgtMAX PCU Difference between the flow andreturn temperatures too great

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

L12 STB OPEN PCU Maximum boiler temperatureexceeded (STB thermostatmaximum)

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

No water circulation

4 Vent the air in the heating system4 Check the circulation (direction pump

valves)4 Check the water pressure

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 34

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 36: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Faults Causeof thefault

Description Checking solution

L14 BURNER FAILURE PCU 5 burner start-up failures No ignition

4 Contact the professional who takes care ofmaintenance of the appliance

Ignition arc but no flame formation

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the appliancePresence of the flame but insufficient ionization(lt3 microA)

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL16 PARASIT FLAME PCU Detection of a parasite flame Ionization current present even though there is no

flameIgnition transformer defectiveGas valve defectThe burner remains very hot O2 too low

4 Contact the professional who takes care ofmaintenance of the appliance

L17 VALVE FAIL PCU Problem on the gas valve SU PCB faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L34 FAN FAILURE PCU The fan is not running at the rightspeed

Bad connectionFan defective

4 Contact the professional who takes care ofmaintenance of the appliance

L35 BACKgtBOIL FAIL PCU Flow and return reversed Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

Water circulation direction reversed

4 Check the circulation (direction pumpvalves)

L36 I-CURRENT FAIL PCU The flame went out more than 5times in 24 hours while the burnerwas operating

No ionization current

4 Check that the gas valve is fully opened4 Contact the professional who takes care of

maintenance of the applianceL37 SU COMFAIL PCU Communication failure with the SU

PCBBad connection

4 Contact the professional who takes care ofmaintenance of the appliance

L38 PCU COMFAIL PCU Communication failure between thePCU and SCU PCBs

Bad connectionSCU PCB not connected or faulty

4 Contact the professional who takes care ofmaintenance of the appliance

L39 BL OPEN FAIL PCU The BL inlet opened for a short time Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

35 15032016 - 300026080-001-07

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 37: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Faults Causeof thefault

Description Checking solution

L40 TESTHRUFAIL PCU HRUURC unit test error Bad connectionExternal causeParameter incorrectly set

4 Contact the professional who takes care ofmaintenance of the appliance

L250 DEFWATER MIS PCU The water pressure is too low Hydraulic circuit incorrectly ventedWater leakMeasurement error

4 Top up with more water if necessary4 Reset the boiler

L251 MANOMETRE FAIL PCU Fault on the water pressure sensor Wiring problemThe manometer is defectSensor pcb defect

4 Contact the professional who takes care ofmaintenance of the appliance

D03D04

OUTL SB FAILOUTL SC FAIL

SCU Circuit B flow sensor faultCircuit C flow sensor faultRemarksThe circuit pump is runningThe 3-way valve motor on the circuitis no longer powered and can beadjusted manually

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D05 OUTSISFAIL SCU Outside temperature sensor faultRemarksThe boiler operates on BOILERMAX temperatureThe valve setting is no longerensured but monitoring themaximum temperature of the circuitafter the valve is ensuredValves may be manually operatedReheating the domestic hot waterremains ensured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D07 AUXSENSFAIL SCU Auxiliary sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D09 DHW SFAILURE SCU Domestic hot water sensor faultRemarksHeating of domestic hot water is nolonger ensuredThe load pump operatesThe load temperature of the dhwtank is the same as the boiler

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D11D12D13

ROOM SA FAILROOM SB FAILROOM SC FAIL

SCU A room temperature sensor faultB room temperature sensor faultC room temperature sensor faultNoteThe circuit concerned operateswithout any influence from the roomsensor

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D14 MC COMFAIL SCU Communication failure between theSCU PCB and the boiler radiomodule

Bad connection

4 Contact the professional who takes care ofmaintenance of the appliance

Boiler module failure

4 Contact the professional who takes care ofmaintenance of the appliance

AGC 1015 AGC 15 AGC 25 AGC 35 7 Troubleshooting

15032016 - 300026080-001-07 36

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 38: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Code Faults Causeof thefault

Description Checking solution

D15 STTANK SFAIL SCU Storage tank sensor faultNoteThe hot water storage tank reheatingoperation is no longer assured

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D16D16

SWIMB SFAILSWIMC SFAIL

SCU Swimming pool sensor fault circuit BSwimming pool sensor fault circuit CNoteSwimming pool reheating is alwaysdone during the circuitrsquos comfortperiod

Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D17 DHW 2 SFAIL SCU Sensor fault tank 2 Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D18 STTANK SFAIL SCU Solar tank sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D19 SOLCOLSFAIL SCU Header sensor fault Bad connectionSensor fault

4 Contact the professional who takes care ofmaintenance of the appliance

D20 SOL COMFAIL SCU Interruption in communication between the SCU PCB and the solar control system

4 Contact the professional who takes care of maintenance of the applianceD27 PCU COM FAIL SCU Communication failure between the SCU and PCU PCBs

4 Contact the professional who takes care of maintenance of the applianceD32 5 RESETONOFF SCU 5 resets done in less than an hour

4 Switch the boiler off and switch back on4 If the boiler does not start after several resets (5 attempts possible) contact your

heating engineer and inform him of the error message displayedD37 TA-S SHORT-CIR SCU The Titan Active Systemreg is short-circuited

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D38 TA-S DISCONNEC SCU The Titan Active Systemreg is on an open circuit

4 Contact the professional who takes care of maintenance of the applianceRemarksDomestic hot water production has stopped but can nonetheless be restarted using keyrThe tank is no longer protectedIf a tank without Titan Active Systemreg is connected to the boilercheck that the TASsimulation connector (delivered with package AD212) is fitted to the sensor card

D99 DEFBAD PCU SCU The SCU software version does not recognise the PCU connected

4 Contact the professional who takes care of maintenance of the appliance

7 Troubleshooting AGC 1015 AGC 15 AGC 25 AGC 35

37 15032016 - 300026080-001-07

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 39: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

8 Energy savings

81 Energy-saving advice

4 Keep the room in which the boiler is installed well ventilated4 Do not block ventilation outlets4 Do not cover the radiators Do not hang curtains in front of the

radiators4 Install reflective panels behind the radiators to prevent heat

losses4 Insulate the pipes in rooms that are not heated (cellars and lofts)4 Close the radiators in rooms not in use4 Do not run hot (or cold) water pointlessly4 Install a water-saving shower head to save up to 40 energy4 Take showers rather than baths A bath consumes twice as much

water and energy

82 Recommendations

The remote control is available in the following versions

4 Wire4 Radio

The setting of the control panel andor of the remote control has aconsiderable influence on energy consumption

A few tips

4 In the room in which the room thermostat is installed itrsquos advisednot to use thermostatic valve radiators If a thermostatic valve isused the valve must be fully opened

4 Completely closing and opening thermostatic valve radiatorscauses undesirable temperature fluctuations Open and closethermostatic valves in small steps

4 Lower the temperature to around 20degC This reduces heating costsand energy consumption

4 Lower the temperature when you air the rooms4 When setting a time schedule bear days when you are absent

and holidays in mind

AGC 1015 AGC 15 AGC 25 AGC 35 8 Energy savings

15032016 - 300026080-001-07 38

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 40: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

9 Warranty

91 General

You have just purchased one of our appliances and we thank you forthe trust you have placed in our products

Please note that your appliance will provide good service for a longerperiod of time if it is regularly checked and maintained

Your installer and our customer support network are at your disposalat all times

92 Warranty terms

The following provisions are not exclusive of the buyer being ablebenefit from the legal provisions applicable regarding hidden defectsin the buyerrsquos country

Starting from the purchase date shown on the original installerrsquosinvoice your appliance has a contractual guarantee against anymanufacturing defect

The length of the guarantee is mentioned in the price catalogueThe manufacturer is not liable for any improper use of the applianceor failure to maintain or install the unit correctly (the user shall takecare to ensure that the system is installed by a qualified engineer)

In particular the manufacturer shall not be held responsible for anydamage loss or injury caused by installations which do not complywith the following

4 applicable local laws and regulations4 specific requirements relating to the installation such as national

andor local regulations4 the manufacturerrsquos instructions in particular those relating to the

regular maintenance of the unit4 the rules of the profession

The warranty is limited to the exchange or repair of such parts as havebeen recognised to be faulty by our technical department and doesnot cover labour travel and carriage costs

The warranty shall not apply to the replacement or repair of partsdamaged by normal wear and tear negligence repairs by unqualifiedparties faulty or insufficient monitoring and maintenance faultypower supply or the use of unsuitable fuel

Sub-assemblies such as motors pumps electric valves etc areguaranteed only if they have never been dismantled

The legislation laid down by european directive 9944EECtransposed by legislative decree No 24 of 2 February 2002 publishedin OJ No 57 of 8 March 2002 continues to apply

9 Warranty AGC 1015 AGC 15 AGC 25 AGC 35

39 15032016 - 300026080-001-07

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 41: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

en

Appendix

Information on the ecodesign and energy labelling directives

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 42: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

Contents1 Specific information 3

11 Recommendations 312 Ecodesign Directive 313 Technical data 314 Circulation pump 415 Disposal and Recycling 416 Product fiche - Boiler space heaters 417 Product data sheet - Temperature controls 418 Package fiche - Boilers 5

Contents

2 300026080 - ErP03 - 29032016

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 43: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

1 Specific information

11 Recommendations

NoteOnly qualified persons are authorised to assemble install and maintain the installation

12 Ecodesign Directive

This product conforms to the requirements of European Directive 2009125EC on the ecodesign of energy-related products

13 Technical data

Tab1 Technical parameters for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Condensing boiler Yes Yes Yes YesLow-temperature boiler(1) No No No NoB1 boiler No No No NoCogeneration space heater No No No NoCombination heater No No No NoRated heat output Prated kW 10 15 25 35

Useful heat output at rated heat output and high temperature regime(2)

P4 kW 104 149 248 348

Useful heat output at 30 of rated heat output and low temperature regime(1)

P1 kW 35 50 83 116

Seasonal space heating energy efficiency ƞs 93 94 94 94

Useful efficiency at rated heat output and high temperature regime(2)

ƞ4 895 895 894 893

Useful efficiency at 30 of rated heat output and low temperature regime(1)

ƞ1 993 993 992 996

Auxiliary electricity consumption Full load elmax kW 0024 0031 0045 0062Part load elmin kW 0020 0021 0019 0021Stand-by PSB kW 0004 0004 0004 0004

Other characteristics Standby heat loss Pstby kW 0078 0078 0078 0085

Ignition burner power consumption Pign kW - - - -

Annual energy consumption QHE GJ 31 46 77 107

Sound power level indoors LWA dB 37 46 51 53

Emissions of nitrogen oxides NOX mgkWh 28 30 34 38

(1) Low temperature means for condensing boilers 30degC for low temperature boilers 37degC and for other heaters 50degC return temperature (at heater inlet)

(2) High temperature regime means 60degC return temperature at heater inlet and 80degC feed temperature at heater outlet

1 Specific information

300026080 - ErP03 - 29032016 3

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 44: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

SeeThe back cover for contact details

14 Circulation pump

NoteThe benchmark for the most efficient circulators is EEI le 020

15 Disposal and Recycling

WarningRemoval and disposal of the boiler must be carried out by a qualishyfied installer in accordance with local and national regulations

If you need to remove the boiler proceed as follows1 Switch off the boiler2 Cut the electrical power to the boiler3 Close the main gas valve4 Close the water mains5 Close the gas valve on the boiler6 Drain the installation7 Remove the air vent hose above the siphon8 Remove the siphon9 Remove the airflue gas pipes

10 Disconnect all pipes on the underside of the boiler11 Dismantle the boiler

16 Product fiche - Boiler space heaters

Tab2 Product fiche for boiler space heatersProduct name AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency class A A A A

Rated heat output (Prated or Psup) kW 10 15 25 35Seasonal space heating energy efficiency 93 94 94 94Annual energy consumption GJ 31 46 77 107Sound power level LWA indoors dB 37 46 51 53

SeeFor specific precautions on assembly installation and mainteshynance see the chapter on Safety Instructions

17 Product data sheet - Temperature controls

Tab3 Product data sheet for the Temperature controls DIEMATIC iSystemClass IIContribution to space heating energy efficiency 2

Fig1 Recycling

MW-3000179-03

1 Specific information

4 300026080 - ErP03 - 29032016

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 45: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

18 Package fiche - Boilers

Fig2 Package fiche for boilers indicating the space heating energy efficiency of the package

AD-3000743-01

1

lsquoIrsquo

2

+

3

( - lsquoIrsquo ) x 01 = plusmn

4

(lsquoIIIrsquo x + lsquoIVrsquo x ) x 09 x ( 100) x = +

(1)

A = 095 A = 091

B = 086 C = 083

D - G = 081

5

( - lsquoIrsquo ) x lsquoIIrsquo = +

6

05 x 05 x = -

54

lt30

G F E D C B A A+

A++

A+++

+ (50 x lsquoIIrsquo) =

7

7

from fi che of solar device

Solar contribution AND Supplementary heat pump

Solar contribution

The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed

in a building as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the

products in relation to building size and characteristics

Boiler and supplementary heat pump installed with low temperature heat emitters at 35degC

Seasonal space heating energy effi ciency class of package

Seasonal space heating energy effi ciency of package

OR

Seasonal space heating energy effi ciency (in ) Supplementary heat pump

Tank rating

Collector effi ciency (in

)

Tank volume (in msup3) Collector size (in msup2)

Seasonal space heating energy effi ciency (in ) Supplementary boiler

Class I = 1 Class II = 2 Class III = 15

Class IV = 2 Class V = 3 Class VI = 4

Class VII = 35 Class VIII = 5

Temperature control

Seasonal space heating energy effi ciency of boiler

(1) If tank rating is above A use 095

select smaller value

from fi che of heat pump

from fi che of heat pump

from fi che of boiler

from fi che of temperature control

I The value of the seasonal space heating energy efficiency of the preferential space heater expressed in

1 Specific information

300026080 - ErP03 - 29032016 5

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 46: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

II The factor for weighting the heat output of preferential and suppleshymentary heaters of a package as set out in the following table

III The value of the mathematical expression 294(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

IV The value of the mathematical expression 115(11 Prated) whereby lsquoPratedrsquo is related to the preferential space heater

Tab4 Weighting of boilersPsup (Prated + Psup)(1)(2) II package without hot water storage tank II package with hot water storage tank0 0 001 03 03702 055 07003 075 08504 085 09405 095 09806 098 100ge 07 100 100(1) The intermediate values are calculated by linear interpolation between the two adjacent values(2) Prated is related to the preferential space heater or combination heater

Tab5 Package efficiencyDe Dietrich - AGC AGC 1015 AGC 15 AGC 25 AGC 35Seasonal space heating energy efficiency of boiler 93 94 94 94Temperature control + 2 + 2 + 2 + 2Seasonal space heating energy efficiency of package 95 96 96 96

1 Specific information

6 300026080 - ErP03 - 29032016

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers
Page 47: AGC 35 AGC 25 - De Dietrich 2020-05-09 · 6.1 General instructions .....28 6.2 Periodic checks .....28 7 Troubleshooting ... AGC 10/15 AGC 15 AGC 25 AGC 35 1. Safety instructions

AD

001N

U-A

J

DUEDI Srl

DE DIETRICH SERVICE

BDR Thermea (Czech republic) sro

wwwduediclimait

wwwdedietrichcz

Distributore Ufficiale EsclusivoDe Dietrich-Thermique Italia

wwwdedietrich-heiztechnikcom

Freecall 0800 201608

Jeseniova 277056130 00 Praha 3

+49 (0)25 72 9161-0+49 (0)25 72 9161-102

inforemehade

Via Passatore 12 - 12010San Defendente di CervascaCUNEO

+39 0171 857170+39 0171 687875infoduediclimait

+420 271 001 627dedietrichbdrthermeacz

IT

DE DIETRICH THERMIQUE Iberia SLUwwwdedietrich-calefacciones

CSalvador Espriu 1108908 LrsquoHOSPITALET de LLOBREGAT

+34 935 475 850infodedietrich-calefacciones

ES

129164 Россия г МоскваЗубарев переулок д 151

Бизнес-центр laquoЧайка Плазаraquo офис 309

+7 (495) 221-31-51

CZ

DE DIETRICH THERMIQUE SAS

infodedietrichru

copy CopyrightAll technical and technological information contained in these technical instructionsas well as any drawings and technical descriptions supplied remain our propertyand shall not be multiplied without our prior consent in writing

15032016

300026080-001-07

DE DIETRICH THERMIQUE

57 rue de la Gare F- 67580 MERTZWILLER - BP 30

  • ErP UG AGC 1015-15-25-35=2=PDF (BDR A4 Manual)=en-GBpdf
    • Contents
    • 1 Specific information
      • 11 Recommendations
      • 12 Ecodesign Directive
      • 13 Technical data
      • 14 Circulationpump
      • 15 Disposal and Recycling
      • 16 Product fiche - Boiler space heaters
      • 17 Product data sheet - Temperature controls
      • 18 Package fiche - Boilers