The Dako FLEX RTU solution Ensures optimal staining results, slide after slideUsing validated protocols and optimized reagents reduces the risk of false negative or false positive results. A robust, specific and sensitive IHC assay is critical for providing staining results that support an accurate patient diagnosis. Dako FLEX RTU is developed in collaboration with pathology experts to ensure optimal staining results.
Advanced Staining Dako FLEX RTU
DATA SHEET
Plug and play on Dako advanced staining platforms
�� Pre-diluted and carefully selected for specificity and sensitivity
�� Proven concept since 2007�� Excellent antibody quality -
confirmed by various EQA schemes
�� Broad portfolio of IVD antibodies
FLEX RTU antibodies
�� Proven visualization with low complexity and very high sensitivity (Skaland et al. 2009)
�� Visibility of antigen in high and low expressing tissue
�� Kit configuration provides – Flexibility – Consistency – Simplicity
EnVision™ FLEX visualization system
Validated protocols
� Automated protocols developed for Dako solutions
� Optimized, validated protocols developed in cooperation with leading pathologists
� Robust protocols compensate for pre-analytical variations
The solution consists of:
�� Pre-diluted antibody — FLEX RTU antibody�� Visualization system — EnVision™ FLEX/FLEX+ �� Optimized and validated protocol — the recipe for consistent high-quality results
Dako protocols provide consistent high-quality resultsThe most important element in the qualification of the staining results of clinical samples is accurate selection and staining of control tissue.
Dako protocols are the result of a comprehensive study of numerous different tissue types, tissue thicknesses, protocol-step durations, target-retrieval methods, antibody dilutions, and pre-analytical variations.
The Dako optimized protocol ensures that every test performance is highly robust, accurate and consistent, compensating for variations in pre-analytical parameters to provide diagnostic certainty slide after slide.
Find the most up-to-date range of FLEX RTU antibodies for all of our advanced staining platforms at www.dako.com/products
2906
9 15
AU
G13
Australia +61 3 9357 0892
Canada +1 905 335 3256
France +33 1 64 53 61 44
Japan +81 3 5802 7211
Poland +48 58 661 1879
United Kingdom +44 (0)1 353 66 99 11
Austria +43 1 408 43 34 0
China +86 21 3612 7091
Germany +49 40 69 69 470
Korea +82 2 402 6775
Spain +34 93 499 05 06
United States of America +1 805 566 6655
Belgium +32 (0) 16 38 72 20
Denmark +45 44 85 97 56
Ireland +353 1 479 0568
The Netherlands +31 20 42 11 100
Sweden +46 8 556 20 600
Brazil +55 11 50708300
Finland +358 9 348 73 950
Italy +39 02 58 078 1
Norway +47 23 14 05 40
Switzerland +41 41 760 11 66
www.dako.com
Represented in more than 100 countries
Corporate Headquarters Denmark +45 44 85 95 00
Non-optimized incubations
Pre-analytical variation
Pre-analytical variation
IHC protocols with unsaturated incubations increase total output variation
IHC protocols with saturated incubations minimize total output variation
Analytical variation
Analytical variation
Total variation
Total variation
Optimized incubations