Div. of TMP Technologies Inc.Advanced Rubber Products
ADVANCED RUBBER PRODUCTS
Silicone Polymer Tie Top Line Post Insulators
15kV, 25kV, 35kV, 46kV, 69kV
6110 Lamb Road • Wyoming, NY 14591 www.arp-hivoltageinsulators.comPhone: 585.495.6231 • Fax: 585.495.6526 email: [email protected]
RUSACCEPTED
™
Advanced Rubber Products Div. of TMP Technologies Inc.
Silicone Polymer Tie Top Line Post Insulators
Camden Printing Form 12559 - Rev. 10-15 (25621)
7/8” BOLT THREAD
CA
TALO
G N
o. AR
P-LP
FN-69S
K-34
69kV LIN
E P
OS
T INS
ULA
TOR
TIE TO
P
DIM
EN
SIO
NS
LEA
KA
GE
DIS
TAN
CE
1,387 mm
(54.61 inches)D
RY
AR
CIN
G D
ISTA
NC
E 550 m
m(21.65 inches)
SH
ED
S Q
'TY 8 P
CS
ME
CH
AN
ICA
L VA
LUE
SS
PE
CIFIE
D C
AN
TILEV
ER
LOA
D 2,450 LB
SR
OU
TINE
CA
NTILE
VE
R LO
AD
1,225 LBS
ELE
CTR
ICA
L VA
LUE
SLow
-Freq.FLAS
HO
VE
R-D
RY
230 kVLow
-Freq.FLAS
HO
VE
R-W
ET
200 kVIM
PU
LSE
FLAS
HO
VE
R-P
OS
380 kVIM
PU
LSE
FLAS
HO
VE
R-N
EG
470 kV
PA
CK
ING
INFO
RM
ATIO
NN
ET W
EIG
HT E
AC
H 14 kg
PA
CK
ED
WE
IGH
T EA
CH
14.4 kgN
O. IN
STA
ND
AR
D P
AC
KA
GE
3 PC
S
NO
TE:
1. TIE TO
P E
ND
FITTING
S A
RE
MA
DE
FRO
M A
LUM
IMU
M A
LLOY
.2. FIB
ER
GLA
SS
RO
D IS
MA
DE
FRO
M E
PO
XY
RE
SIN
.3. S
TUD
BA
SE
DIM
EN
SIO
NS
AR
E IN
AC
CO
RD
AN
CE
WITH
AN
SI C
29.74. TH
E D
IA. O
F FRP
RO
D IS
45mm
(1.77 inches) SO
LID.
5. BA
SE
AN
D IN
SU
LATO
R A
SS
EM
BLE
D W
ITH 3/4" B
OLT A
ND
WA
SH
ER
.6. S
UR
FAC
E O
F TIE TO
P E
ND
FITTING
AR
E C
OTE
D W
ITH "A
NO
DIZN
G"
CA
TALO
G N
o. A
RP
-LP
FN-6
9SK
-34
69kV
LIN
E P
OS
T IN
SU
LATO
R T
IE T
OP
DIM
EN
SIO
NS
LEA
KA
GE
DIS
TAN
CE
1,3
87 m
m(5
4.61
inch
es)
DR
Y A
RC
ING
DIS
TAN
CE
550
mm
(21.
65 in
ches
)S
HE
DS
Q'T
Y8
PC
S
ME
CH
AN
ICA
L V
ALU
ES
SP
EC
IFIE
D C
AN
TILE
VE
R L
OA
D
2,45
0 LB
SR
OU
TIN
E C
AN
TILE
VE
R L
OA
D
1,
225
LBS
ELE
CTR
ICA
L V
ALU
ES
Low
-Fre
q.FL
AS
HO
VE
R-D
RY
230
kVLo
w-F
req.
FLA
SH
OV
ER
-WE
T
20
0 kV
IMP
ULS
E F
LAS
HO
VE
R-P
OS
380
kVIM
PU
LSE
FLA
SH
OV
ER
-NE
G
47
0 kV
PA
CK
ING
INFO
RM
ATI
ON
NE
T W
EIG
HT
EA
CH
1
4 kg
PA
CK
ED
WE
IGH
T E
AC
H
14.
4 kg
NO
. IN
STA
ND
AR
D P
AC
KA
GE
3
PC
S
NO
TE:
1. T
IE T
OP
EN
D F
ITTI
NG
S A
RE
MA
DE
FR
OM
ALU
MIM
UM
ALL
OY
.2.
FIB
ER
GLA
SS
RO
D IS
MA
DE
FR
OM
EP
OX
Y R
ES
IN.
3. S
TUD
BA
SE
DIM
EN
SIO
NS
AR
E IN
AC
CO
RD
AN
CE
WIT
H A
NS
I C29
.74.
TH
E D
IA. O
F FR
P R
OD
IS 4
5mm
(1.7
7 in
ches
) SO
LID
.5.
BA
SE
AN
D IN
SU
LATO
R A
SS
EM
BLE
D W
ITH
3/4
" BO
LT A
ND
WA
SH
ER
.6.
SU
RFA
CE
OF
TIE
TO
P E
ND
FIT
TIN
G A
RE
CO
TED
WIT
H "A
NO
DIZ
NG
"
Catalog Number ANSI Class
“X” Section Length Inches /
(mm)
Bolt Hole Diameter Inches
Major Shed Diameter
Inches / (mm)
Minor Shed Diameter
Inches / (mm)
No. of Sheds
Leakage Distance Inches /
(mm)
Dry Arc Distance
Inches / (mm)
SCL Specified Cantilever Load
lbs / (kN)
Max Design
Cantilever Load
lbs / (kN)
Tensile Strengthlbs/(kN)
Flashover ANSI Critical Flashover ANSI RIV
Net Weight lbs/kg
Parts Per BoxDry (kV) Wet (kV) Pos
(kV)Neg (kV)
Test (kV)
Max (µv)
ARP-LPCN-15SK “C” Neck 12.32 (313) .75 4.53 (115) 3.54 (90) 4 14.06 (357) 7.76 (197) 2800 (12.5) 1350 (6) 4950 (22) 86 66 146 193 10 2.5 8 (17.64) 6
ARP-LPFN-15SK “F” Neck 12.32 (313) .75 4.53 (115) 3.54 (90) 4 14.06 (357) 7.76 (197) 2800 (12.5) 1350 (6) 4950 (22) 86 66 146 193 10 2.5 8.5 (18.74) 6
ARP-LPFN-25SK “F” Neck 16.70 (424) .75 4.53 (115) 3.54 (90) 6 21.69 (551) 12.32 (313) 2800 (12.5) 1350 (6) 4950 (22) 122 103 208 271 15 2.5 9.67 (21.31) 6
ARP-LPFN-35SK “F” Neck 19.01 (483) .75 4.53 (115) 3.54 (90) 7 25.51 (648) 14.57 (370) 2800 (12.5) 1350 (6) 4950 (22) 141 122 239 309 22 2.5 10.17 (22.41) 6
ARP-LPFN-46SK “F” Neck 24.41 (620) .875 6.69 (170) - 7 47.05 (1195) 19.17 (487) 2450 (11) 1240 (5.5) 4950 (22) 188 168 310 376 44 2.5 13.06 (28.79) 1
ARP-LPFN-46SK-34 “F” Neck 24.41 (620) .75 6.69 (170) - 7 47.05 (1195) 19.17 (487) 2450 (11) 1240 (5.5) 4950 (22) 188 168 310 376 44 2.5 13.06 (28.79) 1
ARP-LPFN-69SK-34 “F” Neck 27.20 (691) .75 6.69 (170) - 8 54.61 (1387) 21.65 (550) 2450 (11) 1240 (5.5) 4950 (22) 230 200 380 470 44 2.5 14.55 (32.08) 1
CATALOG No. ARP-LPFN-69SK-34
69kV LINE POST INSULATOR TIE TOP
DIMENSIONSLEAKAGE DISTANCE 1,387 mm(54.61 inches)DRY ARCING DISTANCE 550 mm(21.65 inches)SHEDS Q'TY 8 PCS
MECHANICAL VALUESSPECIFIED CANTILEVER LOAD 2,450 LBSROUTINE CANTILEVER LOAD 1,225 LBS
ELECTRICAL VALUESLow-Freq. FLASHOVER-DRY 230 kVLow-Freq. FLASHOVER-WET 200 kVIMPULSE FLASHOVER-POS 380 kVIMPULSE FLASHOVER-NEG 470 kV
PACKING INFORMATIONNET WEIGHT EACH 14 kgPACKED WEIGHT EACH 14.4 kgNO. IN STANDARD PACKAGE 3 PCS
NOTE:
1. TIE TOP END FITTINGS ARE MADE FROM ALUMIMUM ALLOY.2. FIBERGLASS ROD IS MADE FROM EPOXY RESIN.3. STUD BASE DIMENSIONS ARE IN ACCORDANCE WITH ANSI C29.74. THE DIA. OF FRP ROD IS 45mm(1.77 inches) SOLID.5. BASE AND INSULATOR ASSEMBLED WITH 3/4" BOLT AND WASHER.6. SURFACE OF TIE TOP END FITTING ARE COTED WITH "ANODIZNG"
-34
-343/4” BOLT THREAD
NOTE:
1. TOP END FITTING IS MADE FROM ALUMINUM ALLOY & ANODIZED2. BASE END FITTING IS MADE FROM CARBON STEEL FORGED & GALVANIZED3. CLAMP & STUD BASE DIMENSIONS ARE IN ACCORDANCE WITH ANSI C29.184. FIBERGLASS ROD IS MADE FROM EPOXY RESIN5. THE DIA OF FRP ROD IS 1.57” (40MM) SOLID FOR 15-35 kV6. THE DIA OF FRP ROD IS 1.77” (45MM) SOLID FOR 46-69 kV
™