FSP 150CC-GE20x Product TrainingCourse 1 - Introduction
FSP 150CC-GE206 R4.4.xFSP 150CC-GE201 R4.3.x
November 2010 V1.3
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
2/25
2010 ADVA Optical Networking. All rights reserved. Confidential.2
Prerequisites
Attendee should have knowledge of Telecom power andgrounding practices, Ethernet, TCP-IP, PC-Windows, related testequipment and tools. i.e. our purpose is not to teach telecom,but how to apply prior knowledge and experience to FSP 150CCproducts.
No other ADVA Optical Networking courses are required
PC with serial port and admin access.
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
3/25
2010 ADVA Optical Networking. All rights reserved. Confidential.3
Tech Support Contacts
The ADVA Optical Networking Web Page www.advaoptical.com News And Updates
Partner Login for Our Customers And Partners Contact [email protected] for a Login String and an Access
Password that is changed monthly
The ADVA Optical Networking Service Team Support And Contacts Europe:
t +49 (0)89 89 0665 848
f +49 (0)89 89 0665 22848
North America: t 886 442 ADVA (2382) (toll-free within the US, Canada, & Mexico)
t +1 806 741 8529 (elsewhere)
Asia: t +65 6562 8148
f +65 6562 8154
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
4/25
2010 ADVA Optical Networking. All rights reserved. Confidential.4
Product Overview
Introduction
Application
Key Functions
General Characteristics
Environmental
Regulatory and Safety
LEDs
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
5/25
2010 ADVA Optical Networking. All rights reserved. Confidential.5
The FSP 150CC-GE206 is a next generation Ethernet demarcation unitdesigned for Synchronous Ethernet and cellular backhaul applications
Main Features: Multiple Client GbE ports
Synchronous Ethernet support on all traffic carrying interfaces except of copperSFPs
IEEE 1588v2 Time of Day (Future)
Single E1/T1 input/output clock interface Industrial Temperature (-40 C to +65 C)
802.1ad Provider Bridge C-Tag / S-Tag Mapping
MEF Compliant 3 Color Marking and 8 levels CoS
802.3ah (EFM OAM), 802.1ag (CFM), ITU-T Y.1731 OAM
Network Port Protection option (1+1)
Etherjack support (excluding ECPA in the initial release) 2x Personality Modules (future)
FSP 150CC-GE206Introduction
FSP 150CC-GE206 Front View
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
6/25
2010 ADVA Optical Networking. All rights reserved. Confidential.6
FSP 150CC-GE206Product Variants
GE206F 6 SFP access ports, 2 SFP network ports 0061705890 only copper SFP supported.
GE206 Hardware Rev 2.x 3 x SFP access ports, 3 x electrical accessports, 2 x SFP network ports
GE206 Hardware Rev 1.x is not supported on R4.4.
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
7/25 2010 ADVA Optical Networking. All rights reserved. Confidential.7
The FSP 150CC-GE201 is a next generation single client port Ethernetdemarcation unit designed for Synchronous Ethernet and cellularbackhaul applications
Main Features: Single Client GbE ports
Synchronous Ethernet support on all traffic carrying interfaces
IEEE 1588v2 Time of Day (Future)
Single E1/T1 input/output clock interface
Industrial Temperature (-40 C to +65 C)
802.1ad Provider Bridge C-Tag / S-Tag Mapping
MEF Compliant 3 Color Marking and 8 levels CoS
802.3ah (EFM OAM), 802.1ag (CFM), ITU-T Y.1731 OAM, MEF Y.1731 SLM
Network Port Protection option (1+1)
Etherjack support (including ECPA)
FSP 150CC-GE201Introduction
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
8/25
2010 ADVA Optical Networking. All rights reserved. Confidential.8
FSP 150CC-GE201Product Variants
GE201S SyncE support and BITS timing
GE201 No SyncE, no BITS
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
9/25
2010 ADVA Optical Networking. All rights reserved. Confidential.9
FNC FLASHWAVE 9410-1G SyncE support and BITS timing
All 3 product variants will have the same software load
FSP 150CC-GE201Product Variants (contd)
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
10/25
2010 ADVA Optical Networking. All rights reserved. Confidential.10
Etherjack demarcation device ideal forlarge and small enterprise applications
Good service definition (UNI)
Full suite of OAM (NTE)
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
11/25
2010 ADVA Optical Networking. All rights reserved. Confidential.11
ApplicationCellular Backhaul
Packet
Switch
Network
E1/T1
(ATM)
E1/T1
(TDM)
STM1/OC3
(E1/T1)
ETHERNET
(DATA)
Ethernet
Uplink
STM1/OC3
(E1/T1)
PWE3 TRAFFIC
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
12/25
2010 ADVA Optical Networking. All rights reserved. Confidential.12
GE201 Single client port 1 x 10/100/1000 Mbps electrical or 100/1000 Mbps optical port (SFP)
GE206 - Aggregate traffic from 6 client ports plus expansion slots GE206 - 3 x 10/100/1000 Mbps electrical ports and 3 x 100/1000 Mbps SFP ports
GE206F - 6 x 100/1000 Mbps SFP ports
Supports copper SFP for 10/100/1000 Mbps operation
Network ports 2 x 1000 Mbps
Optional protection
Ethernet UNI/NNI & NID Port/VLAN based service definition and QoS
VLAN Manipulation (add, remove, swap)
Link layer and service layer Ethernet OAM In-band management and remote software upgrade
Etherjack Features Performance Monitoring
Port and VLAN loopbacks
Etherjack Service Assurance
ECPA
FSP 150CC-GE20XKey Functions
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
13/25
2010 ADVA Optical Networking. All rights reserved. Confidential.13
FSP 150CC-GE20XKey Functions Synchronization Overview
Synchronous Ethernet (ITU-T G.8261) Frequency lock nodes in the Ethernet Physical layer
Providing fan-out from Central office to remote CES islands
Ethernet Equipment Clock (ITU-T G.8262)
Ethernet Sync Messaging Channel (ITU-T G.8264)
Ethernet clock quality level messages
External Clock / Timing Inputs
Building Integrated Timing Systems (BITS)
Input
Output
GE206 Single sync reference source GE201 - Sync Reference Switching
Up to 4 sync reference sources
G.781 defines an automatic selection process which can work in 2 distinctmodes: QL-enabled
QL-disabled (Priority Mode)
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
14/25
2010 ADVA Optical Networking. All rights reserved. Confidential.14
Product OverviewFSP 150CC-GE206 Interfaces
ManagementInterfaces
6 Client Interfaces
3 x 10/100/1000BT RJ453 x 100/1000 Optical (SFP)
Redundant PSUs(AC and DC)
Timing
(BITS Input,BITS Output)
Time of Day ToD(future)
Circuit Emulation Modules(Future)
Network Interfaces2 x 100/1000 Optical SFP
1+1 Protection available
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
15/25
2010 ADVA Optical Networking. All rights reserved. Confidential.15
ManagementLAN (RJ-45, Auto-Neg, Auto-MDIX)Serial (RJ-45 [EIA 232], ASCII)
Client Interface10/100/1000BT RJ45
or100/1000 Optical (SFP)
Redundant PSUs120 VAC-48 VDC+24 VDC
TimingBITS InputBITS Output
Network Interfaces2 ports10/100/1000BT RJ45, or100/1000 Optical (SFP)1+1 Protection
Product OverviewFSP 150CC-GE201 Interfaces
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
16/25
2010 ADVA Optical Networking. All rights reserved. Confidential.16
Product OverviewFSP 150CC-GE20X General
17.2 W x 8.6 D x 1.75 H
Mounting Options:
Rack and wall mount kit available
Stack up to 5 rows high before a heat deflector is needed
Power:
Dual hot-pluggable PSUs
AC operating voltage range: 90 to 264 VAC (AC PSU)
DC operating voltage range: -36 to -72 VDC (-48VDC PSU)
DC operating voltage range: +18 to +30 VDC (+24VDC PSU)
Single lockable connector for external AC/DC adapter (rear)
Country specific power cords
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
17/25
2010 ADVA Optical Networking. All rights reserved. Confidential.17
Product OverviewEnvironmental
FSP 150CC-GE206 Operating Temp:
-40 Cto +65 C
Storage Temp: -40 to +70 C
Humidity: 5% 95% non condensing
No fans!
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
18/25
2010 ADVA Optical Networking. All rights reserved. Confidential.18
Product OverviewRegulatory and Safety
Regulatory / Safety
UL/cUL/EN 60950
NEBS Level 3
FCC Part 15, Class B
Industry Canada CS-03 CISPR
CE Mark
VCCI
TV
AS/NZS
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
19/25
2010 ADVA Optical Networking. All rights reserved. Confidential.19
Product OverviewGE206 LEDs
PSU MGMTLink | RatePSU Active/StandbyNetwork
Facility
System Access FacilityAccess PortsLink | RateNetwork Ports
Link | Rate
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
20/25
2010 ADVA Optical Networking. All rights reserved. Confidential.20
LED Color Definition
PSU Status Off
Green
Red
No Power
PSU OK
PSU Fault
System Status Off
Green
RedFlashing Yellow
No system power
System OK, normal operation
System FailureBoot loader stage:
Software download or Databasebackup/restore
Facility (Network and Access) Off
Green
Yellow
Yellow FlashingRed
Unassigned
Operating
Remote Fault , Degraded Facility
LoopbackLink Failure
Active/Standby (unprotected) Off
Green
Not assigned to a Protection Group
Active
Active/Standby (protected) YellowGreen
Standby
Active
Product OverviewGE206 LED Behavior
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
21/25
2010 ADVA Optical Networking. All rights reserved. Confidential.21
Product OverviewGE206 LED Behavior (continued)
LED Color Definition
Access (4-6) Network (1-2) Link Off
Green
Flashing Green
No link detected
Link detected
Activity
Access (4-6) Network (1-2) Rate Off
Yellow
Green
No link detected
100M
1000MAccess (1-3) Link Off
Green
Flashing Green
No link detected
Link detected
Activity
Access (1-3) Rate Off
Yellow
Green
No traffic or 10M
100M
1000M
MGMT Link Off
Green
Flashing Green
No link detected
Link detected
Activity
MGMT Rate Off
Yellow
Green
No link detected
10M
100M
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
22/25
2010 ADVA Optical Networking. All rights reserved. Confidential.22
Product OverviewGE201 LEDs
PSU MGMTLink | Rate
PSU Active/StandbyNetworkFacility
System Access PortsLink | RateNetwork Ports
Link | Rate
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
23/25
2010 ADVA Optical Networking. All rights reserved. Confidential.23
LED Color Definition
PSU Status Off
Green
Red
No Power
PSU OK
PSU Fault
System Status Off
Green
RedFlashing Yellow
No system power
System OK, normal operation
System FailureBoot loader stage:
Software download or Databasebackup/restore
Facility (Network and Access) Off
Green
Yellow
Yellow Flashing
Red
Unassigned
Operating
Remote Fault , Degraded Facility
Loopback
Link Failure
Active/Standby (unprotected) Off
Green
Not assigned to a Protection Group
Active
Active/Standby (protected) YellowGreen
Standby
Active
Product OverviewGE201 LED Behavior
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
24/25
2010 ADVA Optical Networking. All rights reserved. Confidential.24
Product OverviewGE201 LED Behavior (continued)
LED Color Definition
Network (1-2) - Link Off
Green
Flashing Green
No link detected
Link detected
Activity
Network (1-2) - Rate Off
Yellow
Green
No link detected
100M
1000MAccess 1 - Link Off
Green
Flashing Green
No link detected
Link detected
Activity
Access 1 - Rate Off
Yellow
Green
No traffic or 10M
100M
1000M
MGMT Link Off
Green
Flashing Green
No link detected
Link detected
Activity
MGMT Rate Off
Yellow
Green
No link detected
10M
100M
7/22/2019 Adva - Training - FSP 150CC-GE20x R4.x Course - 1 - Introduction
25/25
IMPORTANT NOTICE
The content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content,material, and information in this presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited.
The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representationsof any kind, either express or implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss ordamages, including without limitation, direct, indirect, incidental, consequential and special damages, alleged to have been caused by
or in connection with using and/or relying on the information contained in this presentation.
C i ht f th ti t t f thi t ti ADVA O ti l N t ki
End of Introduction