30
ADAPT ABILITY IN HOUSING ChristopherGebhardt Housing Terminal Studio Prof. Michael Fifield Winter-Spring 2014 “Architecture that is designed for adaptation recognizes that the future is not finite, that change is inevitable, but that a framework is an important element in allowing that change to happen.” -Kronenburg, Flexible: Architecture That Responds to Change. 9 9 RAUSCH

Adaptable Housing

Embed Size (px)

DESCRIPTION

Terminal Thesis Studio Project

Citation preview

  • ADAPTABILITYIN HOUSING

    ChristopherGebhardtHousing Terminal Studio

    Prof. Michael Fi eld Winter-Spring 2014

    Architecture that is designed for adaptation recognizes that the future is not nite, that change is inevitable, but that a framework is an important element in allowing that change to happen.-Kronenburg, Flexible: Architecture That Responds to Change.9 9

    RAUSCH

  • The available data on residential mobility within the U.S. shows that people move for a wide variety of reasons, but analysis of those reasons shows that there are general trends and commonalities that can allow a designer to address issues that will be relevant for a large number of people. For example, 62% of local moves are made for housing related reasons, 26% are made for family related issues.

    Regardless of the specic reason, the decision to move is about the need for change. Since buildings are generally considered static and permanent, change in a life situation usually means moving to a different building. The fundamental premise of this project is that when people need change, instead of them needing to move to different housing, their current housing should be able to change, or adapt, to meet their new needs.

    This project is an exploration of the ability of a building to adapt to meet the changing needs of its inhabitants. It will explore the issues surrounding residential mobility in America. What is it that makes so many of us pick up our roots and set them down in a new location? How many of the needs that drive people to do this can be met by thoughtful and innovative housing design? Can we enjoy the benets of a community we have invested ourselves in while also having housing that works for our current life circumstances?

    STATISTICS

    SITE SIZE:

    BUILDING TYPE:

    NUMBER OF UNITS:

    UNIT DENSITY:

    UNIT TYPES:

    COMMERCIAL SPACE:

    99 Rausch St. San Francisco, CA (SOMA District)

    .75 ACRESMID-RISE RESIDENTIAL/MIXED-USE

    66 UNITS 88 D.U./A.

    STUDIOS, 1 AND 2 BEDROOM FLATS, 3 BEDROOM UNITS

    2600ft2

  • All data from: Donald J. Bogue, Why Americans Move, in Immigration, Internal Migration, and Local Mobility in the U.S., ed. Donald J. Bogue, Gregory Leigel, and Michael Kozloski (Cheltenham, UK: Edward Elgar Publishing Limited, 2009), 3058.

    Why Americans Move

    Quality Issues 30.6%

    Quantity Issues 25.9%

    Other Issues 41.4%New/Better HouseBetter NeighborhoodHealth Reasons (Accessibility)

    Change in Marital StatusEstablish Own HouseholdLook for Work/Lost JobRetiredCheaper Housing

    Closer to Work/CommuteWanted to Own HomeAttend CollegeChange of ClimateOther Family ReasonOther Job Related ReasonOther Housing ReasonOther Reasons

    24.4%4.8%1.4%

    7.0%9.5%0.5%0.2%8.7%

    3.4%12.2%

    1.8%0.2%9.8%0.4%

    11.7%1.9%

    41.4%

    30.6%

    25.9%

    Type Analysis: Local Moves

    Total does not equal 100 due to rounding in each catagory

    Quality Issues - Addressed through good design in this project and the possibility for units facade interfaces to be upgraded

    Quantity Issues - Addressed through the ability of the units to be recongured, expanded, or shrunk by either the developer or the occupant.

    Other IssuesThe scope of this project is limited to issues that can be addressed in a single housing development. The designer recognizes that there are many reasons for residential mobility that cannot be addressed in this project.

    Shiftable Units Subdividable Units Recongurable Units

    Pedestrian Friendly Street Edge Accessible UnitsGood Neighborhood

    Housing-Related Reasons

    Family-Related Reasons

    Work-Related Reasons

    Other

    Local Moves

    Internal Migration Immigration

    New/Better House

    Cheaper Housing

    Better Neighborhood

    Wanted to Own Home

    Other housing reason

    Change in Marital Status

    Establish Own Household

    Other Family Reason

    New Job/Job Transfer - 0%

    Retired

    Closer to Work/Commute

    Look for Work/Lost Job

    Other Job Related Reason

    Housing-Related Reasons Family-Related ReasonsWork-Related Reasons

    Attend College

    Health Reasons

    Change of Climate

    Other Reasons

    Other Reasons

    Reasons for Moving by Type of Mobility, 2005

    Reason For Moving Total Mobile Local Mobility Internal Migration Immigration

    All Movers 100 100 100 100

    Family-Related Reasons 27.1 26.3 29.3 19.6Change in Marital Status 7.1 7 7.8 3.4Establish Own Household 7.8 9.5 5.7 3.5Other Family Reason 12.2 9.8 15.8 12.7

    Work-Related Reasons 17.6 4.4 29.3 55.1New Job/Job Transfer 10.4 0 20 30.5Look for Work/Lost Job 1.9 0.5 2.4 15Closer to Work/Commute 3.4 3.3 3.9 1.3Retired 0.5 0.2 1 0.4Other Job Related Reason 1.4 0.4 2 7.9

    Housing-Related Reasons 47.1 61.8 29.9 9.9Wanted to Own Home 9.3 12.2 5.9 1.4New/Better House 17.8 24.4 9.7 3.4Better Neighborhood 4 4.8 3.3 0.4Cheaper Housing 6.6 8.7 4.2 1.2Other housing reason 9.4 11.7 6.8 3.5

    Other Reasons 8 5.3 11.3 15.4Attend College 3.2 1.8 4.9 6.5Change of Climate 0.6 0.2 1.3 0.1Health Reasons 1.6 1.4 2 1Other Reasons 2.6 1.9 3.1 7.8

  • SITE FEATURES: .3 MILES FROM BART.1 MILES FROM BUS LINES.2 MILES FROM 10 CARSHARES .1 MILES FROM 2 PARKS.2 MILES FROM 2 SUPERMARKETS

    SOMA District, San FranciscoCLIMATE Wind Rose

    Psychrometric Chart

    Monthly Temperatures

    Data from U.S. Department of Energy and Climate Consultant 5.4

  • 99 Rausch San Francisco, CA

  • UP

    DN

    DN

    DN

    DN

    DN

    DN

    DN

    UP

    UP

    UP

    UP

    UP

    UP

    Ofce

    Retail

    Laundry

    Resident

    Services

    Trash

    Bike Parking

    Mech.

    Elec.

    ExitLoading

    19.1

    17.4

    22.6

    21.4

    20.6Floor 1

    Rausch St. Folso

    m St

    .

    A

    B

    0 10 20 40

  • DN

    UP

    UP

    UP

    DN

    DNUP

    UP

    DN

    DNUP

    UP

    DN

    DN

    Housing Plan Floors 2 and 3

    A

    B

    UP

    DN

    DN

    DNUP

    UP

    DN

    UP

    DN

    UP

    Housing Plan Floors 4 and 5

    Roof Deck

    Emergency Egress

    A

    B

    0 10 20 40

    Section A: facing northwest

    0 10 20

    Section B: facing northeast

    0 10 20

  • One Bedroom Pair Two Bedroom and Studio632sf each 817sf and 475sf

    0 5 10 201/8 = 1

    One Bedroom Adaptability

  • Two Bedroom 967sf One Bedroom w/ Expanded Living Space 967sf

    12 O

    pen

    ing

    = 3

    Sh

    eets

    of

    Dry

    wal

    l

    0 5 10 201/8 = 1

    Two Bedroom Adaptability

  • 796 and 680 sf2x1 Bedroom and Three BedroomCongurations

    0 5 10 201/8 = 1680 and 796 sf

    oo

    Three Bedroom Lower Floors

    Three Bedroom Adaptability

  • Fully Shaded

    Partially Shaded

    Vertically Shaded

    Open Position

    Shading Position

    Full Balcony

    Juliet Balcony

    Double Facade

    Solid Panels

    Ideal World Real World

    Panels that easily clip onto the mullion system allow users to adapt to seasonal changes in desired solar access while also customizing their units interaction with the outdoors through visual access or upgrades such as larger balconies.

    Shades slide on simple tracks concealed in joints between wall panels, allowing the users to cutomize solar access without requiring any installation or uninstallation.

    Window Adaptations

    NightEveningMorning

    Hopper Window

    Sliding ExteriorSun-shades

    Awning Window

    Inward OpeningCasement Windows

    Spandrel Panel

    Track Concealedin Panel Seam

    Juliet BalconyRailing

    Floor Level

    Possible Removable Panelfor Full Door

    One Bedroom Adaptability

    1/2 = 10 51 3

    Facade Adaptability

  • Plan

    Section0 5 10 20

    Courtyard Social Node

    Courtyard Social Node

  • DN

    Plan

    Section

    0 5 10 20

    Roof Deck

    Roof Deck

  • Ground Level0' - 0"

    Level 215' - 0"

    Level 12' - 0"

    Level 325' - 0"

    Ground Level0' - 0"

    Level 215' - 0"

    Level 325' - 0"

    Folsom St. Edge

    Rausch St. Edge0 5 10

    Rausch Street

    Street Edge

  • Slot Circulation - Exterior

    Slot Circulation - Interior

    Slot Circulation

  • FHA Covered

    ADA Covered

    FHA Accessibility Compliance

    B

    RE

    TA

    IL

    LOB

    BY

    RE

    SID

    EN

    T

    SER

    VIC

    ES

    LOA

    DIN

    G

    HOUSING UNITS HOUSING UNITS

    Requirement 1 ComplianceAccessible building entrance on an accessible route

  • Requirement 7 ComplianceUsable kitchens and bathrooms

    FHA Accessibility Compliance

    ScaleChecked by As in

    AChecker

    1/4" = 1'-0"Accessibility - Bathroom

    1/4" = 1'-0"Accessibility - Kitchen

    1/8" = 1'-0"Unit Entrance Accessibility

  • FHA Accessibility Compliance

    One Bedroom Two Bedroom 967sf Three Bedroom Lower Floor

    Requirement 4 ComplianceAccessible routes into and through covered units

  • BRETA

    IL

    LOBB

    Y

    RESI

    DEN

    T

    SERV

    ICES

    LOAD

    ING

    FOLS

    OM ST

    .RAUSCH

    ST.

    LAN

    GTON ST.

    HOUSING UNITS

    HOUSING UNITS

    ZONE HEIGHT/BULK DISTRICT

    RED

    F-NCT

    40-X

    65-X

    RESIDENTIAL ENCLAVE DISTRICT

    FOLSOM-NEIGHBORHOOD COMMERCIAL TRANSIT DISTRICT

    Southwest Elevation

    Parapet - 62 - 0

    Parapet - 40 - 0

    Zones: F-NCT RED notesDwelling Units P P 66 Dwelling Units Provided Unit Mix 40% 2 bedroom required, 10% 3 bedrooms requested 38 1-Bedroom=57.5%, 24 2-Bedroom=36%, 4 3-Bedroom=6% General Retail P NP 3500 SF provided on Folsom, in NCTDevelopment on Lots Over a Certain Size C on lots over 10,000 ft No restrictions Building Site of 33,000 SF, but approved for BARDwelling Unit Density Limit None, see mix above None, see mix aboveFAR for non-residential uses 2.5:1 2.5:1 Provided: .2

    Usable Open Space per Dwelling Unit

    80sf if private, 106 if common 80sf private or common

    16 RED Ground units: 1280sf private required 2800 provided.28 NCT Units: 2968 common required. 32 RED units: 2560 common required. 5528 total common required: 6,200 provided

    Open Space for non-residential uses

    N/A

    Required, amount varies by use, may also pay in-lieu fee. none provided

    Off-street parking for residential use

    None required, permitted up to one car per two units or .75 cars per unit

    None required, permitted up to 3 cars per 4 dwelling units, considered up to 1 car per unit none provided

    Off-street parking for non-residential use None required, amount permitted depends on use

    None required, amount permitted depends on use none provided

    Demolition/Subdivision of UnitsConsidered Considered

    Sublets are legal but units cannot be divided or combined without extensive planning review.

    Residential Density

    No residential density limit by lot area. Density restricted by physical envelope controls of height, bulk, setbacks, open space, exposure, of this and other codes, as well as applicable design guidelines, applicable elements and area plans of the General Plan, and design review by the Planning Department. No density (813.03) 88 Units/Acre, 131 Bedrooms/Acre

    Height and Bulk District 65-X 40-X

    Height and Bulk: 65-X 40-X notesHeight Limit 65' 40'Plan Limits n/a n/a

    Zoning

  • Type IIA

    Type IA

    Construction Types

    B

    MAX. COMMON PATH: 125

    MAX. PROVIDED: 45

    MA

    X. E

    GR

    ESS

    PA

    TH

    : 250

    MA

    X. P

    RO

    VID

    ED

    : 53

    Notes

    Occupancy Type:

    Construction Type:

    Type IIA IA

    Primary Structural Frame 1 3

    Exterior Bearing Walls 1 3Exterior Non-Bearing Walls x30 - 0 x

  • 55 : 0 HOURS REQUIRED

    45 : 0 HOURS REQUIRED

    9-8

    : 1

    HO

    UR

    S R

    EQ

    UIR

    ED

    9-6

    : 1

    HO

    UR

    S R

    EQ

    UIR

    ED

    9-6

    : 1

    HO

    UR

    S R

    EQ

    UIR

    ED

    9-6

    : 1

    HO

    UR

    S R

    EQ

    UIR

    ED

    9-6

    : 1

    HO

    UR

    S R

    EQ

    UIR

    ED

    - T

    YP

    E II

    IA

    88:

    0 H

    OU

    RS

    RE

    QU

    IRE

    D -

    TY

    PE

    IA88

    : 0

    HO

    UR

    S R

    EQ

    UIR

    ED

    - T

    YP

    E II

    IA

    55 : 0 HOURS REQUIRED

    0 : 1 HOURS REQUIRED - TYPE IIIA0 : 2 HOURS REQUIRED - TYPE IA

    49 : 0 HOURS REQUIRED - TYPE IIIA49 : 0 HOURS REQUIRED - TYPE IA

    9-6

    : 2

    HO

    UR

    S R

    EQ

    UIR

    ED

    - T

    YP

    E IA

    45 : 0 HOURS REQUIRED

    Non-Loadbearing Exterior Wall Required Fire Ratings

    Permitted Window Glazing

    20% of Conditioned Floor Area

    40% WWR

    California Energy Code Low-Rise (Rausch Walk-Ups) High Rise (Folsom)Climate Zone

    Conditioned Floor Area4920 x 3 = 14760 6015 x 3 = 18045

    8459 x 5 = 42295 for energy budget

    Fenestration Maximum U-Factor 0.32

    Operable Window 0.46Fixed Window 0.36Maximum SHGCMaximum Fenestration Area 20% Floor Area: 2952, 3609 40% WWR for prescriptive package

    Orientation(1.5.3): South/North Facing East/West FacingPrescriptive Package A

    Roofs/Ceilings R-30 U-.039Walls Above Grade R-15+4 or R-13+5 U-.110Ducts R-6Spandrel Panel and Curtain Wall Assembly

    U-.280

    Roof Solar Reflectance Index 75Roof Minimum Thermal Emittance

    0.75

    Occupancy Risk CategoryUniform Assumed Live Loads

    II40 psf (private residences)

    3

    NR

    Codes

  • Bearing Wall Diagram

    Bearing Walls 1/16 = 1

    n.t.s.

    10-6 typ.

    14 typ.

    10-6 typ.

    Architects Studio Companion:

    Lightweight Steel Joists

    Nom

    inal

    Joi

    st D

    epth

    Span6 120 16 24

    2

    5

    8

    11

    DNDDDN

    UPUUUUUUUUUUUUUUUPP

    UPUUUUUUUUUUUUUUUUUUUPP

    UUUUUUUU

    UUUUU

    Bearing Walls

  • Shear Diagram

    Shear Walls1/16 = 1

    n.t.s.

    DNDDDN

    UPUUUUUUUUUUUUUUUPP

    UPUUUUUUUUUUUUUUUUUUUPP

    UUUUUUUU

    UUUUU

    AISI Table C2.1-3 Nominal Shear Strength for Seismic Loads for Shear Walls

    Assembly DescriptionMax Aspect Ratio (h/w)

    DesignatioRequired

    Sheathing Screw Size

    2 to 1 780 990 - - 33 or 43 82 to 1 890 1330 1775 2190 43 or 54 82 to 1 700 915 - - 33 82 to 1 825 1235 1545 2060 43 or 54 82 to 1 940 1410 1760 2350 54 82 to 1 1232 1848 2310 3080 68 10

    0.018" steel sheet, one side

    2 to 1 390 - - - 33 (min) 8

    0.027" steel sheet, one side

    4 to 1 - 1000.00 1085.00 1170.00 33 (min) 8

    Fastener Spacing at Panel Edges (Inches)

    7/16" OSB, one side

    15/32" Structural 1 Sheathing (4-ply), one

    Shear Walls

  • Plan View Section View

    Unit Separation Wall Assembly

    Exterior Wall Assembly

    5/8 Type X gypsum board

    5 5/8 Steel Stud

    R-21 Fiber Batt Insulation

    Moisture Barrier

    R-10 Expanded Polystyrene Rigid Insulation

    1/2 Air Gap

    Slenderwall Concrete Panel

    Thermaguardtm Insulated Stainless Steel

    Connection Anchor

    6x6 Hot-DippedGalvanized Welded

    Wire Mesh Reinforcing

    2 thick sound attenuation blanket

    3 5/8 metal studs, 24 o.c.

    California Ofce of NoiseControl Section #1.3.3.1.5.10STC: 50 Required, 51 Provided

    5/8 Type X gypsum board spot-laminated to studs with daubs of adhesive 12 o.c. Drywall screws at third points along joints and ends

    R-30 Expanded Polystyrene Rigid Insulation

    1/4 Dens-Deck

    3 Steel Decking Treated Wood Blocking

    Loose Stone Ballast

    EPDM Membrane Loosely Laid Membrane Protection Layer

    Hot-air Welded In-place

    Treated Wood Deck Post

    Roof Assembly Roof Deck Detail

    1 = 1

    1 = 1

    1 = 1

    Lightweight SteelStud Construction

    Cost: Approx. 1.5 x Wood Stud Construction

    Construction Type: I or II

    Shear Wall Types: Diagonal straps, sheet steel, proprietary narrow piers, plywood, manufactured board products.

    Advantages: Versatile, easily worked with common tools, inexpensive, lighter and stronger than wood framing, can incorporate holes in the web for wiring and plumbing, can be used in buildings which require non-combustible construction, can be constructed in all weathers, can be combined with wood and structural steel elements.

    DisadvantagesHigh thermal conductivity, high audible conductivity, can lose structural strength and stiffness quickly if exposed to the heat of re.

    Enclosure Details

  • All Slopes 1/4 to 1

    8200sf

    4900sf4900sf

    Roof Drainage Plan

  • DN

    2000sf Water Catchment Area

    Overow to storm drain

    10 yr 1-hour rainfall: .70 = .058

    .058 x 18000sf = 1044ft3 of water

    1044ft3 / 2000sf catchment area = .52 depth = 6.2

    Stormwater Plan

  • Trash

    DN

    UP

    Typical Housing Floor

    Chase Locations

  • UP

    UP

    Alt. Typical Housing Floor

    Chase Locations

    Mini-Split Exterior Unit, Typ.

    Mini-Split Interior Unit Typ.

    Water pipes and sprinklers in plenum created by raised rst oor

    Rainwater piped to catchmentarea in back

    Services

  • I would like to thank my professor, Michael Fi eld, for all his help and guidance over the course of this project, as well as David Israel and BAR Architects for their generous contributions of time and money that allowed this studio to be so much more than a typical two-term project.

    Thanks also to my parents who supported and encouraged me through all my many years of schooling, as well as the great friends I have made through the years for making it such an enjoyable process.

    I de nitely couldnt have done it without you all.

    -Christopher GebhardtB.Arch. Spring 2014

    University of Oregon

  • Rear Courtyard