A0.00
COVERSHEET
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
ARCHITECT
JEFF SPIKES318-828-1637
NAME:PHONE:
PROFESSIONAL OF RECORD:
ALL CONSTRUCTION TO COMPLY WITH LOCAL AND STATE CODES AND STANDARDS
CORRECTING SUCH VIOLATIONS.
BEEN MADE, WILL NOT BE ALLOWED.
CONTRACTOR NOTES
SUBMITTING A BID. REPORT ANY DISCREPANCIES TO ARCHITECT OR
EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE ANDSCOPE OF THE WORK. THE SUBMISSION OF A BID WILL BE EVIDENCETHAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR,EQUIPMENT, OR MATERIALS REQUIRED, OR FOR ANY DIFFICULTIES
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT,AND OWNER OF ANY DISCREPANCIES ENCOUNTERED ON THE PLANS OR IN
CONTRACTORS ARE CAUTIONED TO COORDINATE ITEMS IN THEIR SCOPE OFWORK WITH OTHER TRADES.
EXISTING SITE CONDITIONS PRIOR TO SUBMISSION OF BID.
ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION
VISUALLY APPARENT CODE VIOLATIONS AND ALLOW IN HIS/HER BID FORCONTRACTOR, DURING PRE-BID SITE VISIT, SHALL TAKE NOTICE OF ANY
SPECIFICATIONS , INCLUDING BUT NOT LIMITED TO ARCHITECTURAL, CIVIL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL PRIOR TO
IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL DRAWINGS AND
BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH
E.F.
D.
C.
B.ENGINEER PRIOR TO BID.
A.
THESE NOTES APPLY TO ALL SHEETS.G.
CODE INFORMATION:
SHEET INDEX
SYMBOL LEGEND
SEE DOOR SCHEDULENEW DOOR
A
WALL SECTION MARKER
DOOR NUMBER, SEE SCHEDULE
FINISH ELEVATION
INTERIOR ELEVATION/ LOCATION
ROOM NAME/ ROOM NUMBER
WINDOW NUMBER, SEE SCHEDULE
SECTION DETAIL/ SHEET
BUILDING SECTION MARKER
100ROOM NAME
0.0A0.0
SECTION DETAIL MARK
0.0A0.0
ENLARGED REFERENCE
0.00
0.0A0.0
EL. 000.0'A.F.F.
101
00
0.0A0.0
iARCHiTECTURE, LLC.417 LAKE STREETSHREVEPORT, LOUISIANA 71101
CODES TO BE UTILIZED:
2012 NATIONAL FIRE PROTECT ASSOCIATION (NFPA 101)2012 INTERNATIONAL BUILDING CODE (IBC)2012 INTERNATIONAL MECHANICAL CODE (IMC)2005 NEC2010 (STANDARD) AMERICANS WITH DISABILITIES ACT AND ARCHITECTURAL
BARRIERS GUIDELINES (JULY 23, 2004 EDITION)2013 LOUISIANA STATE PLUMBING CODE (MOST CURRENT VERSION)2012 INTERNATIONAL ENERGY CONSERVATION
SITE LAYOUT MAP
SITE
SHREVEPORTREGIONAL
AIRPORT
SHREVEPORT
DOWNTOWNAIRPORT
AIR FORCEBARKSDALE
RIV
ER
BASE
BOSSIERCITY
RED
ARCHITECTURAL
A0.00 COVER, PROJECT INFO. & LOCATOR PLANSA1.01 SITE/ROOF PLANAD2.01 EXISTING/NEW ROOF PLANAD2.02 EXISTING HANGAR PLANA2.01 NEW ROOF PLAN DETAILSA2.02 HANGAR PLAN
MECHANICAL
MED101 FIRST FLOOR PLAN - MECHANICAL DEMOLITIONMED102 SECOND FLOOR PLAN - MECHANICAL DEMOLITIONM101 FIRST FLOOR PLAN - MECHANICALM102 SECOND FLOOR PLAN - MECHANICALM201 MECHANICAL SCHEDULEM202 MECHANICAL DETAILSM203 MECHANICAL DETAILSE101 FIRST FLOOR PLAN - ELECTRICALE102 SECOND FLOOR PLAN - ELECTRICAL
ALL CONSTRUCTION TO COMPLY WITH LOCAL AND STATE CODES AND STANDARDS
SHREVEPORT REGIONAL AIRPORT
HANGAR 40
REHABILITATION
PHASE-1
6990 CHALLENGER DRIVE, SHREVEPORT, LOUISIANA 71109
PERMIT READY
CONSTRUCTION SET 9/14/16
A MANDATORY PRE-BID MEETING WILL BE HELD AT THE SITE.H.
CHALLENGER DRIVE
AD2.01A1
ROO
F SLOPE
1:12
EXISTING PARKING
SECURED ENTRY
EXISTING PARKINGSHALL NOT BE USED BYCONTRACTORS
SCOPE OF WORK
NOT SCOPE OF WORK
NOT SCOPE OF WORK
NOT SCOPE OF WORK
STAGING AREA
SECURED GATE
MAINTENANCE ENTRYSTAIRWELL
ALLOWABLE CONTRACTORROUTES
HANGER
STORES/GSE
BREAK & RR'S
OFFICES
A
B
C
D
A
B
B
C
C
D
B
A1.01
SITE &ROOF
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
A1 SITE PLAN1" = 40'-0"
KEY PLANN.T.S.
ROOF SLOPE1:12
PREP ALL SURFACES AS PERMANUFACTURER'S REQUIREMENTSTO RECEIVE DEPRESSION FILLERMATERIAL (LOOSE LAID)
70'-0" +/-FIELD VERIFY
252'
-0" +
/-FI
ELD
VE
RIF
Y
38'-6" +/-FIELD VERIFY
43'-6
" +/-
FIEL
D V
ERIF
Y
38'-0" +/-FIELD VERIFY
238'
-6" +
/-FI
ELD
VE
RIF
Y
TEST/VERIFY EXISTING METAL PANELSNEEDING REPAIR PRIOR TO NEW ROOFOVERLAY
EXISTING TRAPEZOIDAL METAL PANELSATTACHED DIRECTLY TO STRUCTURE
HANGER
STORES/GSE
BREAK & RR'S
OFFICES
A
B
C
D
A
B
B
C
C
D
B
ROOF SLOPE1:12
D1/A2.01
D1/A2.01
D1/A2.01
70'-0" +/-FIELD VERIFY
252'
-0" +
/-FI
ELD
VE
RIF
Y
38'-6" +/-FIELD VERIFY
43'-6
" +/-
FIEL
D V
ERIF
Y
38'-0" +/-FIELD VERIFY
238'
-6" +
/-FI
ELD
VE
RIF
Y
NEW SINGLE PLYMEMBRANE ROOF
ROOF PENETRATIONSSEE DETAILS ON SHEET A2.01FOR NEW INSTALLATION
D3/A2.01
D3/A2.01
D3/A2.01
A3/A2.01
A3/A2.01
A3/A2.01
VERTICAL WALL CONDITION@ EXISTING BUILDING
D3/A2.01
D3/A2.01
D3/A2.01
A3/A2.01
EXISTING ROOF HATCH
D5/A2.01
D5/A2.01
NEW GUTTER PER DETAILD5/A2.01 LOCATION AS SHOWN
D1/A2.01
D1/A2.01
D1/A2.01 NEW GUTTER PER DETAILD5/A2.01 LOCATION AS SHOWN
METAL EDGE TRIM PERDETAIL D1/A2.01
FIE
LD V
ER
IFY
FIE
LD V
ER
IFY
NEW ROOF WALKWAY PADS
AD2.01
EXISTING/NEW
ROOF
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
A1 EXISTING ROOF PLAN1/8" = 1'-0"
KEY PLANN.T.S.
A3 NEW ROOF PLAN1/8" = 1'-0"
A
B
B
C
C
D
B
EXISTING FORCED AIR HEATER LOCATIONSUSE EXISTING GAS LINES & ELECTRICAL FOR NEW
IR HEATERS AS LOCATED IN NEW PLAN
EXISTING FORCED AIR HEATER LOCATIONSUSE EXISTING GAS LINES FOR NEW IR HEATERS
GAS SUPPLED @ ALL EXST'G UNIT HEATERS
EXISTING FORCED AIR HEATER LOCATIONSUSE EXISTING GAS LINES FOR NEW IR HEATERSGAS SUPPLED @ ALL EXST'G UNIT HEATERS
DEMO EXISTING HOLLOW METALFIRE RATED FRAME & DOOR, REPLACEAS NOTED
HANGER
STORES/GSE
BREAK & RR'S
OFFICES
A
B
C
D
A
B
B
C
C
D
B
AD2.02
EXISTINGPLAN
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
A1 EXISTING PLAN1/32" = 1'-0"
KEY PLANN.T.S.
EXISTING STANDING SEAM METAL ROOFAPPROVED FLUTE FILLER
WOOD NAILER
24 GA. C-CHANNEL CAPMECHANICALLY ATTACHEDON TOP AND BOTTOM
ROOFING MEMBRANE
TERMINATION
APPROVED RE-COVERBOARD
NOTE 1: IF INSULATION IS LESS THAN 1-INCH THICK, A WOOD NAILER IS NOT REQUIRED.
NOTE 1: ALL JOINTS, SPLICES, CORNERS, AND ENDCAPS ARE TO BE
DECK
PREFABRICATED PARAPET WALL FLASHING
NOTE 1: FASCIA BAR AND COVER MAY BE USED IN PLACE OF THE TERMINATION BAR.
NOTE 2: THE SUBSTRATE MUST BE FREE AND CLEAR OF DEBRIS AT AND BELOW THE TERMINATION POINT.
NOTE 3: WHEN ATTACHING THE PARAPET FLASHING TO THE SUBSTRATE, THE APPROPRIATE FASTENER MUST BE USED. THE FASTENER FOR THE WALL FLASHING MAY BE DIFFERENT THAN THE FASTENER USED ON THE HORIZANTAL ROOF DECKING.
CAULK
COUNTER FLASHING
EXISTING COUNTER FLASHING
TAPER CUT FLUTE FILL
NOTE 1: IT IS PERMISSIBLE TO USE AN APPROVED DURO-GUARD FAN FOLD OVERFLUTE FILLER ON A STANDING SEAM METAL ROOF IF THE SPAN BETWEENTHE FLUTE FILLER AND THE FLUTE DOES NOT EXCEED 1/4 INCH.
NOTE 2: FLUTE FILLER MUST BE 1.5-LB DENSITY EPS INSULATION, OR 2.0-LBDENSITY POLYISOCYANURATE AND HELD IN PLACE. WOOD FIBERBOARDCAN NOT BE USED AS FLUTE FILLER.
NOTE 3: THE USE OF THIS DETAIL IS NOT A FIRE RATED SYSTEM UNLESS AN FR-10PROTECTIVE LAYER IS USED.
STRAIGHT CUT FLUTE FILL
FAN FOLD
PVC ROOFINGMEMBRANE
PVC ROOFINGMEMBRANE
NOTE 1: A 1/4-INCH GAP IS REQUIRED BETWEEN SECTIONS OF DURO-LAST FASCIA BASE. JOINTS ON THE FASCIA BASEMUST BE OFFSET BY A MINIMUM OF 12-INCHES FROM THEJOINTS IN THE METAL COVER.
NOTE 2: A WOOD NAILER IS REQUIRED IF 1-INCH OF INSULATION ORGREATER IS USED. TOP OF WOOD NAILER TO BE FLUSHWITH TOP OF INSULATION. FASTENERS USED TO ATTACHWOOD NAILERS SHALL BE SPACED NO GREATER THAN 18-INCHES ON CENTER.
NOTE 3: THE FASCIA BASE SYSTEM IS NOT TO BE INSTALLED AS AGRAVEL/WATER STOP.
NOTE 4: THIS EDGING IS AVAILABLE IN 4-INCH THROUGH 8-INCH DIMENSIONS.
NOTE 5: DENSDECK PRIME IS THE RECOMMENDED SUBSTRATEBOARD. FOR ADDITIONAL SUBSTRATE OPTIONS SEE SECTION 2 OF THE ADHERED SPECIFICATION OR CONTACTTHE DURO-LAST ENGINEERING SERVICES DEPARTMENT.
CAULK
FASTEN FASCIA BASE USINGSPECIFIED SCREWS. USE ALLPRE-PUNCHED HOLES ONFASCIA BASE.
MEMBRANEADHESIVE
CAULK
DENSDECK PRIME
INSULATION
MEMBRANEADHESIVE
ROUND PENETRATION4070
NOTE 1: IF A LEAD FLASHING IS PRESENT ON THE PIPE, IT MUST BEREMOVED BEFORE STACK FLASHING IS INSTALLED.
NOTE 2: MEMBRANE ATTACHMENT AROUND THE PENETRATION WILLBE THE SAME AS THE DECK MEMBRANE, MAX. 18-INCHES ONCENTER, AND A MINIMUM OF ONE PLATE/FASTENER PERFLASHING.
DECK
TYPICAL VENT PIPE
DURO-LAST PREFABRICATED VENTSTACK FLASHING
FROM THE TOP OF THEPOSITIONED 1/4-INCHSTAINLESS STEEL BAND
STACK FLASHING
8-INCHESMIN.
DURO-LAST CAULK
FASTENERS6-INCHES ON CENTER, MAX.
VINYL-COATED
SEALANT
COUNTER-FLASHING
CAULK
WA
LL
METAL PRE-PUNCHED 6-INCHESON CENTER WITH MEMBRANE SKIRT
THICK, A WOOD NAILER IS NOT REQUIRED.
NOTE 1: ALL JOINTS, SPLICES, CORNERS, AND ENDCAPS ARE TO BERIVETED INTO POSITION. ON SPLICE PLATES, A MINIMUM OF 2RIVETS AND 2 FASTENERS ARE TO BE USED.
NOTE 2: ALL JOINTS, SPLICES, CORNERS AND ENDCAPS MUST HAVEAPPROVED SEALANT APPLIED TO THEM TO ENSURE AWATERTIGHT APPLICATION. APPLY A BEAD OF APPROVEDSEALANT TO THE SPLICE PLATE ON BOTH SIDES OF THEJOINT.
NOTE 3: ONE EXPANSION JOINT SHOULD BE INSTALLED FOR EVERY40-50 FEET OF GUTTER BEING INSTALLED. (DETAIL 2095)
NOTE 4: DRAINAGE SLOPE AND DRAIN SIZES ARE TO BE DETERMINEDBY LOCAL BUILDING CODE REQUIREMENTS AND ARE THERESPONSIBILTY OF THE CONTRACTOR TO FOLLOW.
FASTEN 24-INCHES ONCENTER TO NAILER ORROOF DECK
GUTTER STRAPS(24 TO 30-INCHES
ENDCAPS (RIVET INTO PLACE, 2RIVETS PER SURFACE, MINIMUM)
SPLICE PLATE (LEAVE 14-INCH GAPBETWEEN GUTTER SECTIONS)
ON CENTER) FIELDINSTALLED
STRIP MASTIC(BACK SEAL MEMBRANE)
APPROVED SEALANT
A2.01
NEWROOF
DETAILS
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
A1 EAVE EDGE TERMINATOR3" = 1'-0"
A3 INSIDE WALL TERMINATION3" = 1'-0"
A5 TYPICAL ROOF SECTION REPAIR DETAIL3" = 1'-0"
D1 4"-8" METAL FASCIA BASE3" = 1'-0"
D3 PLUMBING STACK DETAIL3" = 1'-0"
D5 GUTTER ATTACHMENT DETAIL3" = 1'-0"
HAZMAT
MX SUPS
STORES/24,000 SQ. FT.SECURED ENTRY
SHEET METAL
GSE
MECHANICALMEN
WMN
BREAK
MEN WMN
TOOLROOM
TOOLROOM
TYPICAL BAY AREA(TAIL DOCK/POWER/STANDS/TOOLS)
108,000 SQ. FT.
RAMP AREA, PLANE ENTRY
SECRURED STORAGE
35'LX69'WX25'H 35'LX69'WX25'H
35'LX69'WX25'H
35'LX69'WX25'H
35'LX69'WX25'H
HIGH INTENSITY INFRARED HEATERPEREMITER HEATING TYP.MOUNTING HT. @ 40' +/-
(4) FANS 24'-0" MOUNTING HT: MIN. HEIGHT = 25'
PROVIDE FOR ALTERNATE IN FRONTOF HANGAR
EXTEND EXISTING GAS LINE FROM EXISTINGFORCED AIR UNIT TO PROVIDE FOR NEW IR
HEATERS AS SHOWN AT FRONT OF HANGAR IR HEATERS LOCATED @ FRONT OF HANGARMOUNTED ABOVE DOOR FOR CLEARANCE
TYP.
NOTES:
1. HANGAR WILL BE SPLIT INTO (4) EQUAL ZONES.2. THERMOSTATS MOUNTED @ 5'-0" +/- TO CONTROL EACH ZONE.3. VERIFY & UTILIZE EXISTING GAS & ELECTRICAL FROM THE EXISTING FORCED AIR UNITS TO CONTROL THE NEW INFRARED UNITS AS SHOWN & SPECIFIED.
HIGH INTENSITY INFRARED HEATERPEREMITER HEATING TYP.
MOUNTING @ BOTTOM OF STRUCTURE,CLEAR OF HANGAR DOOR
USE EXISTING GAS LINES & ELECTRICALTO BE UTILIZED FOR NEW INFRARED
HEATERS AS SHOWN
NEW HOLLOW METAL FIRE RATED FRAME& DOOR, OPENING 8'-6"x9'-0", MATCHEXISTING HARDWARE & 3HR RATING TO MEETAPPLICABLE CODES
HANGER
STORES/GSE
BREAK & RR'S
OFFICES
A
B
C
D
A
B
B
C
C
D
B
A2.02
HANGARPLAN
DATE 09/14/16
REVISIONS
NO. DATE
PROJECT NO:
IA 1625SHEET
HA
NG
AR
40
RE
HA
BIL
ITA
TIO
NP
HA
SE
1
SH
RE
VEP
OR
T, L
A 7
1109
COPYRIGHT
THESE DOCUMENTS ARE PROTECTED BY UNITED STATES
COPYRIGHT LAW. THEY HAVE BEEN PREPARED SPECIFICALLY
FOR THE PROJECT IDENTIFIED AND ARE NOT SUITABLE FOR
USE ON ANY OTHER PROJECT OR AT ANY OTHER LOCATION
WITHOUT THE EXPRESS WRITTEN APPROVAL AND
PARTICIPATION OF iARCHITECTURE. REPRODUCTION OF
THESE DOCUMENTS MUST BE AUTHORIZED BY THE ARCHITECT.
ALL RIGHTS ARE RESERVED TO iARCHITECTURE.
A1 HANGAR PLAN1/32" = 1'-0"
KEY PLANN.T.S.