proACTpro DESFire EV1 Readers
Installation Manual
ACTpro EV1 1030e - Slimline Proximity Reader
ACTpro EV1 1040e - Proximity Reader
ACTpro EV1 1050e - PIN & Proximity Reader
ACTpro EV1 1030PM - Panel Mount Proximity Reader
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 12
ContentsPage No.
Specifications Table ................................................................................ 3
Product Description ................................................................................ 4
Reader Connections 1040e/1050e .......................................................... 4
Reader Connections 1030e ..................................................................... 5
CAT 5/6 Colour Code .............................................................................. 5
Clock & Data Entry and Exit Reader Wiring Diagrams ............................ 6
Wiegand Entry and Exit Reader Wiring Diagrams ................................... 7
Reader Configuration .............................................................................. 8
1050e Backlight Operation ...................................................................... 9
Buzzer Operation ..................................................................................... 9
Power On Beep Codes ............................................................................ 9
1030PM Connections to Controllers/Doorstations ............................... 10
1030PM Mounting Diagram & Instructions ........................................... 11
1030e Mounting Diagram ...................................................................... 12
1040e/1050e Surface Mounting Diagram ............................................. 13
1040e/1050e Flush Mounting Diagram ................................................. 14
1040e/1050e Flush Mounting to UK Pattress Box Diagram ................. 15
Product Code Description
ACTpro EV1 1030e DESFire EV1 Proximity reader, mullion mount
ACTpro EV1 1030PM DESFire EV1 Proximity reader, panel mount
ACTpro EV1 1040e DESFire EV1 Proximity reader, surface / flush mount
ACTpro EV1 1050e DESFire EV1 Prox & PIN reader, surface / flush mount
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 3
DESFire EV1 1030e
DESFire EV1 1030PM
DESFire EV1 1040e
DESFire EV1 1050e
Connections Pigtail Terminal Block Terminal Block Terminal Block
DimensionsW x H x D 37 x 120 x 15mm 63 x 58 x 23mm 95 x 128 x 19mm 95 x 128 x 21mm
Mounting Mullion Panel Flush or Surface Flush or Surface
Weight 150g 65g 142g 155g
Power Supply 12Vdc-24Vdc 12Vdc-24Vdc 12Vdc-24Vdc 12Vdc-24Vdc
Selectable file, serial &
reverse serialYes Yes Yes Yes
Current Consumption
Typical30mA 30mA 70mA 70mA
Current Consumption
(Peak)130mA 70mA 140mA 140mA
Operating Temperature
-10°C/50°C -10°C/50°C -10°C/50°C -10°C/50°C
Transmit Frequency
13.56MHz 13.56MHz 13.56MHz 13.56MHz
Keypad No No No Yes
Environmental Rating
IP67 IP67 IP67 IP67
Cable Distance
100 m 100 m 100 m 100 m
Output Formats
Wiegand or Clock & Data
Wiegand or Clock & Data
Wiegand or Clock & Data
Wiegand or Clock & Data
Indoor &Outdoor
Yes Yes Yes Yes
PIN or Prox Prox Prox Prox PIN & Prox
Specifications Table
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 14
Reader Connections - ACTpro DESFire EV1 1040e/1050e
0VRED
GREEN
A
B
+12V DCDATA
CLOCK
SENSE
BUZZ
File/SerialOperation Jumper
Product DescriptionACT DESFire EV1 readers support all ACT DESFire EV1 cards.
• Compatible with ACT DESFire EV1 cards• Confi gurable to read DESFire EV1 File Data, Serial Number or Reverse Serial Number• Confi gurable for Wiegand or Clock & Data output
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 5
Reader Connections - ACTpro DESFire EV1 1030e
ACTpro DESFire EV1 1030e is supplied with 3m pigtail cable.
CAT 5/6 Colour Code
The following is suggested colour coding if using CAT5 or CAT6 cabling.
Reader Output
Colour
Sense White/Green
Clock / D1 Green
Data / D0 Blue
+12V Orange
(0V) GND White/Orange
Red LED Brown
Green LED White/Brown
Orange & Purple
Programming File/Serial
ISP Grey (Unused)
CLOCK/D1 (Green)
SENSE (White)
DATA/D0 (Blue)
+12V (Red)
0V/GND (Black)
RED LED (Brown)
GREEN LED (Yellow)
(Orange)
(Purple)
ISP (Grey) - Unused
} Programming File/Serial
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 16
Clock & Data Entry Reader - Wiring
Clock & Data Exit Reader - Wiring
SENSE (White)CLOCK / D1 (Green)
DATA / D0 (Blue)+12V (Red)OV / GND (Black)
RED (Brown)GREEN (Yellow)
BUZZER INPUT(Not available on 1030e)
SENSE (White)CLOCK / D1 (Green)
DATA / D0 (Blue)+12V (Red)OV / GND (Black)
RED (Brown)GREEN (Yellow)
DO NOT CONNECT SENSE (White cable)
BUZZER INPUT(Not available on 1030e)
NB: Illustrations apply to all DESFire EV1 readers
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 7
WIEGAND Entry Reader - Wiring
WIEGAND Exit Reader - Wiring
SENSE CLOCK / D1 (Green)
DATA / D0 (Blue)+12V (Red)OV / GND (Black, White)
RED (Brown)GREEN (Yellow)
BUZZER INPUT(Not available on 1030e)
SENSE (Blue) CLOCK / D1 (Green)
DATA / D0 +12V (Red)OV / GND (Black, White)
RED (Brown)GREEN (Yellow)
BUZZER INPUT(Not available on 1030e)
IMPORTANT: To put ACT readers into wiegand mode connect the SENSE on the reader to 0V/GND.
IMPORTANT: To put ACT readers into wiegand mode connect the SENSE on the reader to 0V/GND PIN and DATA/D0 to the SENSE PIN on the controller.
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 18
Reader Configuration
Operation: ACTpro DESFire EV1 1030PM / 1040e / 1050e
ACTpro DESFire EV1 readers can operate in file, serial or reverse serial mode which is selectable via a jumper. To change the operation mode power down the reader, change the jumper for the desired operation and re-apply power.
Operation: ACTpro DESFire EV1 1030e The operation of the ACTpro DESFire EV1 1030e is selectable via cable configuration. To change the operation power down the reader, change the Orange and Purple cable for the desired operation and re-apply power.
DESFire EV1 File ReaderReads the file data on ACT DESFire EV1 cards.
Serial and Reverse Serial ReaderWhen in Serial or reverse serial mode the DESFire EV1 card serial number (CSN) is read by the reader.
123
DESFireEV1 File
123
Serial123
ReverseSerial
Connect Pins 1&2 Connect Pins 2&3 Do NOT connect Jumper
Colour DESFire EV1 File Serial Reverse Serial
Orange 0V 0V Not Connected
Purple 0V Not Connected 0V
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 9
Backlight Operation - ACTpro DESFire EV1 1050eThe ACTpro DESFire EV1 1050e has backlight illumination of the keypad.
Buzzer OperationThe Internal buzzer is activated by applying 0V to the Buzz PIN. The buzzer activates 4 seconds after the 0V is applied and sounds continuously until the 0V is removed (External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader.
Power On Beep CodesThe Output Data Format and the File/Serial Operation of the reader can be determined by the beeps generated by the reader after power is applied. The reader will generate two sets of beeps, the first indicating the Output Data Format and the second set of beeps indicating File or Serial Operation. The first set of beeps will occur while the LED is Green, the second set of beeps occur half a second later while the LED is Blue.
First Beep Set Double Beep DESFire EV1 Reader Single Beep Serial Reader Triple Beep Serial Reader (byte reverse) Second Beep Set Double Beep Clock & Data Output Single Beep Wiegand 37 bit Output
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 110
123
+12/24VDATA
CLOCKSENSE
0VRED LGREEN LBUZZ
ON
LED
OFF
{EV1 �le Mode
{Serial Mode
Jumper Pins 1 + 2:DESFire EV1 �le operation
Jumper Pins 2 + 3:Serial operation
No Jumper:Byte reversed serial operation
1030PM DESFire EV1 Panel Mount reader connections to ACTpro Door Controllers & Door Stations
LED ControlThe standby LED on the front of the reader can be configured using the jumper. When the jumper is connected between LED and OFF, the blue LED on the front of the reader will remain off while in standby. It will turn green on access granted and red on access denied.
When the jumper is connected between LED and ON, the blue LED on the front of the reader will remain on while in standby. It will turn green on access granted and red on access denied.
White SENSE
Green CLOCK & DATA 1
Blue DATA / DATA 0
Red +12V
Black 0V
Brown RED LED
Yellow GREEN LED
ORANGE (BUZZER Ctrl)
Wiring for Clock & Data / Wiegand ReaderThe standard wiring colours for ACTpro DESFire EV1 readers are shown across.
Readers should be a maximum of 100m when powered from +12V.
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 11
ACTpro DESFire EV1 1030PM Mounting Diagram
Mounting Instructions1. Place the VR screen printed perspex over the four studs on the back of the audio entry panel.2. Place the ACTpro DESFire EV1 panel mount reader over the four studs.3. Use the four M3 washers and nuts supplied with the product to secure the reader to the audio entry panel.4. Connect the reader to the controller5. When wiring is complete, place the front cover back onto the audio entry panel.6. Apply power to the controller and test the reader with a card or fob.
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 112
ACTpro 1030e DESFire EV1 Mounting Diagram
Screw unit to the surface. Place caps on to the unit and push firmly into place.
Screw unit to the surface. Place caps onto the unit and push firmly into place
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 13
ACTpro DESFire EV1 1040e/1050e Surface Mount Diagram
Place the reader / keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar.
The surface mount collar is mounted on the wall using the fixing kit supplied in the box.
Security screw supplied with the unit
Place the cap onto the unit and push firmly in place
The surface mount collar is mounted on the wall using the fixing kit supplied in the box.
Place the reader/keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar.
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 114
ACTpro DESFire EV1 1040e/1050e Flush Mount Diagram
Sec
urity
scr
ew
supp
lied
with
the
unit
Rem
ove
spac
ers
befo
re m
ount
ing
P
lace
the
cap
onto
the
unit
and
push
firm
ly in
pla
ce
Pla
ce th
e re
ader
/ k
eypa
d on
to th
e flu
sh
mou
nt c
olla
r an
d cl
ip d
own
into
pla
ce.
Use
th
e se
curit
y sc
rew
sup
plie
d to
atta
ch th
e un
it to
the
flush
mou
nt c
olla
r.
The
flush
mou
nt c
olla
r is
mou
nted
on
the
wal
l us
ing
the
fixin
g ki
t sup
plie
d in
the
box.
Pre
pare
th
e m
ount
ing
surfa
ce to
rec
eive
sub
-sur
face
te
rmin
als.
ACTpro DESFire EV1 Readers Installation Manual
Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 15
ACTpro DESFire EV1 1040e/1050e Flush Mounting to UK Pattress Box
Mou
ntin
g pl
ate
is a
ttach
ed to
the
pattr
ess
usin
g th
e sc
rew
s su
pplie
d. E
nsur
e th
e co
rrec
t spa
cers
hav
e be
en u
sed
to b
ridge
the
gap
betw
een
the
mou
ntin
g pl
ate
and
the
fixin
g w
ings
of t
he p
attr
ess
box
to a
void
th
e m
ount
ing
plat
e be
ing
dist
orte
d.
Pla
ce th
e re
ader
/ k
eypa
d on
to th
e su
rface
mou
nt c
olla
r an
d cl
ip
dow
n in
to p
lace
. U
se th
e se
curit
y sc
rew
sup
plie
d to
atta
ch th
e un
it to
the
flush
mou
nt c
olla
r.
Sec
urity
scr
ew
supp
lied
with
the
unit
Scr
ews
Sta
ndar
d pa
ttres
s bo
x
Pla
ce th
e ca
p on
to th
e un
it an
d pu
sh fi
rmly
in p
lace
Not
e:D
eter
min
e th
e di
stan
ce b
etw
een
the
pattr
ess
box
and
the
mou
ntin
g pl
ate,
usi
ng th
e sp
acer
s th
at a
rela
belle
d 1m
m to
4m
m. A
spa
cer
of th
e co
rrec
tle
ngth
is a
ssem
bled
by
stac
king
the
spac
ers
toge
ther
.
Spa
cers
bre
ak a
way
fro
m m
ain
com
pone
nt
whe
n re
quire
d by
in
stal
ler
for
use
View
sho
win
g sp
acer
st
acki
ngVi
ew s
how
s m
ount
ing
plat
e be
fore
spa
cers
are
br
oken
aw
ay b
y in
stal
ler
Ireland OfficeUnit C1, South City Business Centre,Tallaght, Dublin, D24 PN28, Ireland
United Kingdom Office601 Birchwood One, Dewhurst Road, Birchwood, Warrington, WA3 7GB, UK
Ireland: +353 (0)1 466 2570UK: +44 (0)161 236 9488Email: [email protected] (USA)
Copyright © 2016 Access Control Technology Ltd. Part No. 18-00107 Issue 1
Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.
While every effort has been taken by ACT to ensure the accuracy of the information contained within this document, ACT assumes no responsibility for any errors or omissions. No liability is assumed for damages resulting from the use of information contained within this document.