16
pro ACTpro DESFire EV1 Readers Installation Manual ACTpro EV1 1030e - Slimline Proximity Reader ACTpro EV1 1040e - Proximity Reader ACTpro EV1 1050e - PIN & Proximity Reader ACTpro EV1 1030PM - Panel Mount Proximity Reader

ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

  • Upload
    volien

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

proACTpro DESFire EV1 Readers

Installation Manual

ACTpro EV1 1030e - Slimline Proximity Reader

ACTpro EV1 1040e - Proximity Reader

ACTpro EV1 1050e - PIN & Proximity Reader

ACTpro EV1 1030PM - Panel Mount Proximity Reader

Page 2: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 12

ContentsPage No.

Specifications Table ................................................................................ 3

Product Description ................................................................................ 4

Reader Connections 1040e/1050e .......................................................... 4

Reader Connections 1030e ..................................................................... 5

CAT 5/6 Colour Code .............................................................................. 5

Clock & Data Entry and Exit Reader Wiring Diagrams ............................ 6

Wiegand Entry and Exit Reader Wiring Diagrams ................................... 7

Reader Configuration .............................................................................. 8

1050e Backlight Operation ...................................................................... 9

Buzzer Operation ..................................................................................... 9

Power On Beep Codes ............................................................................ 9

1030PM Connections to Controllers/Doorstations ............................... 10

1030PM Mounting Diagram & Instructions ........................................... 11

1030e Mounting Diagram ...................................................................... 12

1040e/1050e Surface Mounting Diagram ............................................. 13

1040e/1050e Flush Mounting Diagram ................................................. 14

1040e/1050e Flush Mounting to UK Pattress Box Diagram ................. 15

Product Code Description

ACTpro EV1 1030e DESFire EV1 Proximity reader, mullion mount

ACTpro EV1 1030PM DESFire EV1 Proximity reader, panel mount

ACTpro EV1 1040e DESFire EV1 Proximity reader, surface / flush mount

ACTpro EV1 1050e DESFire EV1 Prox & PIN reader, surface / flush mount

Page 3: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 3

DESFire EV1 1030e

DESFire EV1 1030PM

DESFire EV1 1040e

DESFire EV1 1050e

Connections Pigtail Terminal Block Terminal Block Terminal Block

DimensionsW x H x D 37 x 120 x 15mm 63 x 58 x 23mm 95 x 128 x 19mm 95 x 128 x 21mm

Mounting Mullion Panel Flush or Surface Flush or Surface

Weight 150g 65g 142g 155g

Power Supply 12Vdc-24Vdc 12Vdc-24Vdc 12Vdc-24Vdc 12Vdc-24Vdc

Selectable file, serial &

reverse serialYes Yes Yes Yes

Current Consumption

Typical30mA 30mA 70mA 70mA

Current Consumption

(Peak)130mA 70mA 140mA 140mA

Operating Temperature

-10°C/50°C -10°C/50°C -10°C/50°C -10°C/50°C

Transmit Frequency

13.56MHz 13.56MHz 13.56MHz 13.56MHz

Keypad No No No Yes

Environmental Rating

IP67 IP67 IP67 IP67

Cable Distance

100 m 100 m 100 m 100 m

Output Formats

Wiegand or Clock & Data

Wiegand or Clock & Data

Wiegand or Clock & Data

Wiegand or Clock & Data

Indoor &Outdoor

Yes Yes Yes Yes

PIN or Prox Prox Prox Prox PIN & Prox

Specifications Table

Page 4: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 14

Reader Connections - ACTpro DESFire EV1 1040e/1050e

0VRED

GREEN

A

B

+12V DCDATA

CLOCK

SENSE

BUZZ

File/SerialOperation Jumper

Product DescriptionACT DESFire EV1 readers support all ACT DESFire EV1 cards.

• Compatible with ACT DESFire EV1 cards• Confi gurable to read DESFire EV1 File Data, Serial Number or Reverse Serial Number• Confi gurable for Wiegand or Clock & Data output

Page 5: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 5

Reader Connections - ACTpro DESFire EV1 1030e

ACTpro DESFire EV1 1030e is supplied with 3m pigtail cable.

CAT 5/6 Colour Code

The following is suggested colour coding if using CAT5 or CAT6 cabling.

Reader Output

Colour

Sense White/Green

Clock / D1 Green

Data / D0 Blue

+12V Orange

(0V) GND White/Orange

Red LED Brown

Green LED White/Brown

Orange & Purple

Programming File/Serial

ISP Grey (Unused)

CLOCK/D1 (Green)

SENSE (White)

DATA/D0 (Blue)

+12V (Red)

0V/GND (Black)

RED LED (Brown)

GREEN LED (Yellow)

(Orange)

(Purple)

ISP (Grey) - Unused

} Programming File/Serial

Page 6: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 16

Clock & Data Entry Reader - Wiring

Clock & Data Exit Reader - Wiring

SENSE (White)CLOCK / D1 (Green)

DATA / D0 (Blue)+12V (Red)OV / GND (Black)

RED (Brown)GREEN (Yellow)

BUZZER INPUT(Not available on 1030e)

SENSE (White)CLOCK / D1 (Green)

DATA / D0 (Blue)+12V (Red)OV / GND (Black)

RED (Brown)GREEN (Yellow)

DO NOT CONNECT SENSE (White cable)

BUZZER INPUT(Not available on 1030e)

NB: Illustrations apply to all DESFire EV1 readers

Page 7: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 7

WIEGAND Entry Reader - Wiring

WIEGAND Exit Reader - Wiring

SENSE CLOCK / D1 (Green)

DATA / D0 (Blue)+12V (Red)OV / GND (Black, White)

RED (Brown)GREEN (Yellow)

BUZZER INPUT(Not available on 1030e)

SENSE (Blue) CLOCK / D1 (Green)

DATA / D0 +12V (Red)OV / GND (Black, White)

RED (Brown)GREEN (Yellow)

BUZZER INPUT(Not available on 1030e)

IMPORTANT: To put ACT readers into wiegand mode connect the SENSE on the reader to 0V/GND.

IMPORTANT: To put ACT readers into wiegand mode connect the SENSE on the reader to 0V/GND PIN and DATA/D0 to the SENSE PIN on the controller.

Page 8: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 18

Reader Configuration

Operation: ACTpro DESFire EV1 1030PM / 1040e / 1050e

ACTpro DESFire EV1 readers can operate in file, serial or reverse serial mode which is selectable via a jumper. To change the operation mode power down the reader, change the jumper for the desired operation and re-apply power.

Operation: ACTpro DESFire EV1 1030e The operation of the ACTpro DESFire EV1 1030e is selectable via cable configuration. To change the operation power down the reader, change the Orange and Purple cable for the desired operation and re-apply power.

DESFire EV1 File ReaderReads the file data on ACT DESFire EV1 cards.

Serial and Reverse Serial ReaderWhen in Serial or reverse serial mode the DESFire EV1 card serial number (CSN) is read by the reader.

123

DESFireEV1 File

123

Serial123

ReverseSerial

Connect Pins 1&2 Connect Pins 2&3 Do NOT connect Jumper

Colour DESFire EV1 File Serial Reverse Serial

Orange 0V 0V Not Connected

Purple 0V Not Connected 0V

Page 9: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 9

Backlight Operation - ACTpro DESFire EV1 1050eThe ACTpro DESFire EV1 1050e has backlight illumination of the keypad.

Buzzer OperationThe Internal buzzer is activated by applying 0V to the Buzz PIN. The buzzer activates 4 seconds after the 0V is applied and sounds continuously until the 0V is removed (External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader.

Power On Beep CodesThe Output Data Format and the File/Serial Operation of the reader can be determined by the beeps generated by the reader after power is applied. The reader will generate two sets of beeps, the first indicating the Output Data Format and the second set of beeps indicating File or Serial Operation. The first set of beeps will occur while the LED is Green, the second set of beeps occur half a second later while the LED is Blue.

First Beep Set Double Beep DESFire EV1 Reader Single Beep Serial Reader Triple Beep Serial Reader (byte reverse) Second Beep Set Double Beep Clock & Data Output Single Beep Wiegand 37 bit Output

Page 10: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 110

123

+12/24VDATA

CLOCKSENSE

0VRED LGREEN LBUZZ

ON

LED

OFF

{EV1 �le Mode

{Serial Mode

Jumper Pins 1 + 2:DESFire EV1 �le operation

Jumper Pins 2 + 3:Serial operation

No Jumper:Byte reversed serial operation

1030PM DESFire EV1 Panel Mount reader connections to ACTpro Door Controllers & Door Stations

LED ControlThe standby LED on the front of the reader can be configured using the jumper. When the jumper is connected between LED and OFF, the blue LED on the front of the reader will remain off while in standby. It will turn green on access granted and red on access denied.

When the jumper is connected between LED and ON, the blue LED on the front of the reader will remain on while in standby. It will turn green on access granted and red on access denied.

White SENSE

Green CLOCK & DATA 1

Blue DATA / DATA 0

Red +12V

Black 0V

Brown RED LED

Yellow GREEN LED

ORANGE (BUZZER Ctrl)

Wiring for Clock & Data / Wiegand ReaderThe standard wiring colours for ACTpro DESFire EV1 readers are shown across.

Readers should be a maximum of 100m when powered from +12V.

Page 11: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 11

ACTpro DESFire EV1 1030PM Mounting Diagram

Mounting Instructions1. Place the VR screen printed perspex over the four studs on the back of the audio entry panel.2. Place the ACTpro DESFire EV1 panel mount reader over the four studs.3. Use the four M3 washers and nuts supplied with the product to secure the reader to the audio entry panel.4. Connect the reader to the controller5. When wiring is complete, place the front cover back onto the audio entry panel.6. Apply power to the controller and test the reader with a card or fob.

Page 12: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 112

ACTpro 1030e DESFire EV1 Mounting Diagram

Screw unit to the surface. Place caps on to the unit and push firmly into place.

Screw unit to the surface. Place caps onto the unit and push firmly into place

Page 13: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 13

ACTpro DESFire EV1 1040e/1050e Surface Mount Diagram

Place the reader / keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar.

The surface mount collar is mounted on the wall using the fixing kit supplied in the box.

Security screw supplied with the unit

Place the cap onto the unit and push firmly in place

The surface mount collar is mounted on the wall using the fixing kit supplied in the box.

Place the reader/keypad onto the surface mount collar and clip down into place. Use the security screw supplied to attach the unit to the surface mount collar.

Page 14: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 114

ACTpro DESFire EV1 1040e/1050e Flush Mount Diagram

Sec

urity

scr

ew

supp

lied

with

the

unit

Rem

ove

spac

ers

befo

re m

ount

ing

P

lace

the

cap

onto

the

unit

and

push

firm

ly in

pla

ce

Pla

ce th

e re

ader

/ k

eypa

d on

to th

e flu

sh

mou

nt c

olla

r an

d cl

ip d

own

into

pla

ce.

Use

th

e se

curit

y sc

rew

sup

plie

d to

atta

ch th

e un

it to

the

flush

mou

nt c

olla

r.

The

flush

mou

nt c

olla

r is

mou

nted

on

the

wal

l us

ing

the

fixin

g ki

t sup

plie

d in

the

box.

Pre

pare

th

e m

ount

ing

surfa

ce to

rec

eive

sub

-sur

face

te

rmin

als.

Page 15: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

ACTpro DESFire EV1 Readers Installation Manual

Copyright © 2016 Access Control Technology Ltd. Part No.18-00107 Issue 1 15

ACTpro DESFire EV1 1040e/1050e Flush Mounting to UK Pattress Box

Mou

ntin

g pl

ate

is a

ttach

ed to

the

pattr

ess

usin

g th

e sc

rew

s su

pplie

d. E

nsur

e th

e co

rrec

t spa

cers

hav

e be

en u

sed

to b

ridge

the

gap

betw

een

the

mou

ntin

g pl

ate

and

the

fixin

g w

ings

of t

he p

attr

ess

box

to a

void

th

e m

ount

ing

plat

e be

ing

dist

orte

d.

Pla

ce th

e re

ader

/ k

eypa

d on

to th

e su

rface

mou

nt c

olla

r an

d cl

ip

dow

n in

to p

lace

. U

se th

e se

curit

y sc

rew

sup

plie

d to

atta

ch th

e un

it to

the

flush

mou

nt c

olla

r.

Sec

urity

scr

ew

supp

lied

with

the

unit

Scr

ews

Sta

ndar

d pa

ttres

s bo

x

Pla

ce th

e ca

p on

to th

e un

it an

d pu

sh fi

rmly

in p

lace

Not

e:D

eter

min

e th

e di

stan

ce b

etw

een

the

pattr

ess

box

and

the

mou

ntin

g pl

ate,

usi

ng th

e sp

acer

s th

at a

rela

belle

d 1m

m to

4m

m. A

spa

cer

of th

e co

rrec

tle

ngth

is a

ssem

bled

by

stac

king

the

spac

ers

toge

ther

.

Spa

cers

bre

ak a

way

fro

m m

ain

com

pone

nt

whe

n re

quire

d by

in

stal

ler

for

use

View

sho

win

g sp

acer

st

acki

ngVi

ew s

how

s m

ount

ing

plat

e be

fore

spa

cers

are

br

oken

aw

ay b

y in

stal

ler

Page 16: ACTpro DESFire EV1 Readers Manual - Interact | …External Buzzer Control not available on the ACTpro DESFire EV1 1030) reader. Power On Beep Codes The Output Data Format and the File/Serial

Ireland OfficeUnit C1, South City Business Centre,Tallaght, Dublin, D24 PN28, Ireland

United Kingdom Office601 Birchwood One, Dewhurst Road, Birchwood, Warrington, WA3 7GB, UK

Ireland: +353 (0)1 466 2570UK: +44 (0)161 236 9488Email: [email protected] (USA)

Copyright © 2016 Access Control Technology Ltd. Part No. 18-00107 Issue 1

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

While every effort has been taken by ACT to ensure the accuracy of the information contained within this document, ACT assumes no responsibility for any errors or omissions. No liability is assumed for damages resulting from the use of information contained within this document.