5
ID No. FROM TO NOMINAL DIMENSIONS DOOR TYPE MAT FINISH FRR FRAME TYPE MAT FRAME FRR SYSTEM STC HDWR GROUP NOTES D1 VESTIBULE CORRIDOR 910 X 2115 A HM PT 45 A EXST PT N/A 49 5 D2 418 THEATRE CORRIDOR 1525 X 2425 B WD STN/PT 45 B PM PT 45 51 1 D3 419 STUDIO CORRIDOR 1525 X 2425 B WD STN/PT 45 B PM PT 45 51 1 D4 419 STUDIO CORRIDOR N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TO BE REMOVED D5 419 STUDIO CORRIDOR 915 X 2430 C HM PT 45 C PM PT 45 51 5 D6 419 STUDIO KITCHEN 915X 2430 D EXST PT N/A EXST PT N/A 49 2 EXISTING DOOR & FRAME, NEW SEALS D7 419 STUDIO SOUND BOOTH 900 X 2045 E WD PT N/A PM PT N/A 49 3 D8 418 THEATRE 419 STUDIO 910 X 2120 F WD PT N/A EXST PT N/A 49 4 D9 418 THEATRE 419 STUDIO 910 X 2120 F WD PT N/A EXST PT N/A 49 4 RETAIN HINGES FOR REUSE WITH NEW DOOR. DOOR HARDWARE MOUNTING HEIGHT TO MATCH EXISTING ADJACENT DOORS. CONTRACTOR TO CONFIRM ON SITE PRIOR TO DOOR FABRICATION. TYPE B ±2425 ±1525 TYPE C ±2430 ±915 TYPE A ±2115 ±910 1000 1000 N/A NOT APPLICABLE EXST EXISTING STN WOOD STAIN PT PAINT HM HOLLOW METAL PM PRESSED METAL 915 X 2430 15 TYPE D ±2430 ±915 16 17 18 TYPE F ±2120 ±910 20 TYPE E ±2045 ±900 19 1000 1000 1000 D E F F 418 THEATRE 419 STUDIO 473 CORRIDOR 457 BALLET STUDIO A1 1 A2 1 ID No. FROM TO NOMINAL DIMENSIONS WINDOW TYPE MAT FRAME FRR NOTES W1 SOUND BOOTH 418 THEATRE 1535 X 810 A FG PT N/A W2 SOUND BOOTH 419 STUDIO 905 X 905 B FG PT N/A N/A NOT APPLICABLE EXST EXISTING FG FIBER GLASS PT PAINT 1535 810 905 905 TYPE A TYPE B FRAME TYPE MAT FRAME FRR A FG PT N/A A FG PT N/A GLASS STC 34 34 LAMINATED ACOUSTIC GLASS LAMINATED ACOUSTIC GLASS SLIDER FIXED CASEMENT HORIZONTAL SLIDER REFER TO DETAIL 7 / A4 50 REBATE HEIGHT 50 50 REBATE WIDTH 11 15 C C 13 13 JAMB DEPTH 50 26 16 12 11 13 14 A. FRAME MUST BE INSTALLED AT FINISHED FLOOR HEIGHT. (DO NOT EMBED IN FLOOR). B 13 13 JAMB DEPTH 50 62 A. FRAME MUST BE INSTALLED AT FINISHED FLOOR HEIGHT. (DO NOT EMBED IN FLOOR). 50 REBATE HEIGHT 50 50 50 REBATE (2) REBATE (1) 16 8 10 2 1 3 6 5 4 7 1 3 2 9 1 4 B A A C C 50 8 2 16 NOTES PRESSED STEEL ACOUSTIC FRAME. FIRE RATED PERIMETER NEOPRENE SEAL. PERIMETER SMOKE SEAL. INTUMESCENT STRIP. HINGES. INTUMESCENT HINGE PROTECTION. HINGE REINFORCEMENT, FACTORY WELDED IN FRAME. ACOUSTIC ASTRAGAL FASTENED TO THE PUSH SIDE OF THE INACTIVE DOOR. LEAF. BRACKET AND ADDITIONAL PERIMETER SEALS TO BE FITTED AND FASTENED TO HEADER AT SITE. 12.7mm HIGH STEPPED ACOUSTIC THRESHOLD 127mm WIDTH, TO BE INSTALLED ON FINISHED FLOOR. ACOUSTIC PERIMETER SEAL TO BE FITTED AND FASTENED TO JAMBS, MULLION, AND HEAD. ACOUSTIC NEOPRENE AT HEADER ONLY. INSTALL SECONDARY PERIMETER ACOUSTIC SEAL FOR STC TO BE FITTED AND FASTENED TO JAMBS AND HEAD. 6mm HIGH FLAT ACOUSTIC THRESHOLD 127mm WIDTH, TO BE INSTALLED ON FINISHED FLOOR. TYPE A - NEW HOLLOW METAL DOOR & EXISTING DOOR FRAME. TYPE B - NEW ACOUSTIC WOOD DOUBLE DOORS & NEW PRESSED METAL DOOR FRAME, STAIN WOOD FINISH ON CORRIDOR SIDE, BLACK PAINT FINISH ON SUITE SIDE. TYPE C - NEW HOLLOW METAL DOOR & NEW PRESSED METAL DOOR FRAME. TYPE D - EXISTING DOOR & DOOR FRAME WITH NEW ACOUSTIC HEAD & JAMB SEALS. TYPE F - NEW ACOUSTIC WOOD DOOR & NEW PRESSED METAL DOOR FRAME. TYPE E - NEW ACOUSTIC WOOD DOORS & EXISTING DOOR FRAME. 1 2 3 4 5 6 7 1 KEY PLAN - SECOND LEVEL 1:200 A0 OTTAWA, ONTARIO DRAWING / DESSIN BUSINESS ENTITY / NUMÉRO DE L'ENTITÉ BUILDING NUMBER / NUMÉRO DU BÂTIMENT PROJECT NO. / NUMÉRO DE PROJET SHEET NO. / FEUILLE No. CONSULTANT / EXPERT-CONSEIL CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LA VILLE D'OTTAWA ET TOUT DROIT D'AUTEUR EST RÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONT À DES FINS D'ESTIMATION SEULEMENT. IL INCOMBE À CHAQUE ENTREPRENEUR, SOUS-CONTRACTANT OU CONSULTANT DE VÉRIFIER TOUTES LES DIMENSIONS ET LES CONDITIONS SUR LE CHANTIER. VEUILLEZ INFORMER LE PROPRIÉTAIRE DE TOUTE ERREUR OU OMISSION AVANT D'ENTAMER LES TRAVAUX. NE DRESSEZ PAS LES PLANS À L'ÉCHELLE. CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL PROJECT / LOCATION / PROJET / ENDROIT ARCHITECT / ARCHITECTE THIS DRAWING IS THE PROPERTY OF THE CITY OF OTTAWA AND ALL COPYRIGHT IS RESERVED. DIMENSIONS ON DRAWING ARE FOR ESTIMATING PURPOSES ONLY. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR AND SUB-CONTRACTOR OR CONSULTANT TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE. NOTIFY OWNER OF ANY ERRORS OR OMISSIONS PRIOR TO COMMENCING THE WORK. DO NOT SCALE THE DRAWINGS. (Y/M/D) (A/M/J) MILESTONE / FAIT SAILLANT DATE: FOR / POUR 1 A1.1 SHEET NUMBER DETAIL NUMBER DRAWING TITLE SCALE: NUMBER/ NUMÉRO INITIALS INITIALES PLANNING AND INFRASTRUCTURE PORTFOLIO INFRASTRUCTURE SERVICES DEPARTMENT DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH ________________________________________________________________ PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTURE DÉPARTEMENT DES SERVICES D'INFRASTRUCTURE DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS Fax.: 613-567-9462 Robertson Martin Phone.: 613-567-1361 Email: [email protected] Architects 216 Pretoria Avenue Ottawa, ON, K1S 1X2 Robertson Martin Email: [email protected] Fax.: 613-567-9462 Robertson Martin Phone.: 613-567-1361 Email: [email protected] Architects 216 Pretoria Avenue Ottawa, ON, K1S 1X2 Robertson Martin Email: [email protected] TWSH TWSH TWSH 2014/04/15 2014/03/31 6 5 4 3 2 1 PARKS, RECREATION & CULTURAL SERVICES DESIGN & CONSTRUCTION - BUILDINGS CULTURAL & HERITAGE SERVICES TWSH ISSUED FOR PERMIT ISSUED FOR 95% CLIENT REVIEW 2014/03/11 ISSUED FOR 60% CLIENT REVIEW TWSH AS INDICATED JLG CR009876 BE1029 BU1000 A0 KEY PLAN / SCHEDULES TITLE PAGE 2 DALY AVENUE SECOND FLOOR ARTS COURT CITY OF OTTAWA DOOR SCHEDULE A0 TITLE PAGE / KEY PLAN / SCHEDULES A1 457 BALLET STUDIO & 473 CORRIDOR PLAN ENLARGEMENT & DETAILS A2 418 THEATRE & 419 STUDIO PLAN ENLARGEMENT & DETAILS A3 419 STUDIO INTERIOR ELEVATIONS & DETAILS A4 SOUND BOOTH PLAN ENLARGEMENT, INTERIOR ELEVATIONS, & DETAILS DRAWING LIST A. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDING PERMIT, CONTRACTOR IS RESPONSIBLE FOR ALL OTHER REQUIREMENTS FOR AUTHORITIES HAVING JURISDICTION, INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE. B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS & SPECIFICATIONS. C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALL DIMENSIONS ON SITE. D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENT REPRESENTATIVE IN WRITING OF ANY DISCREPANCIES OF DIMENSIONS, MATERIALS, AND/OR CONDITIONS. E. UNLESS OTHERWISE INDICATED AS EXISTING, ALL MATERIALS ARE NEW AND TO BE SUPPLIED & INSTALLED AS PART OF THIS CONTRACT. F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURN TO THE DESIRED END PLACE BUT WILL NOT BE RESPONSIBLE FOR INSTALLATIONS. G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY A CERTIFIED ELECTRICIAN. H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TO REMAIN. I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHEN PROCEEDING WITH PROJECT WORK. J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECT WORK. K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES. CONTRACTOR TO ASSUME 10% REPLACEMENT. L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES AS PER MASTER PAINTERS INSTITUTE (MPI) PAINTING STANDARD. COORDINATE WITH CLIENT REPRESENTATIVE FOR APPROVED COLOUR SCHEME. M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPI PAINTING STANDARD. COORDINATE WITH DEPARTMENTAL REPRESENTATIVE FOR APPROVED COLOUR SCHEME. GENERAL NOTES CONSTRUCTION ASSEMBLIES ACOUSTIC AND FLOORING UPGRADES TO THE ARTS COURT 16mm (5/8") PLASTER/GYPSUM FINISH 200mm (8") CONCRETE BLOCK 19mm X 89mm (1" X 4") WOOD STRAPPING. 25mm (1") ARTICULATED WOOD PANELING. 1 LAYER 16mm (5/8") GYPSUM w/ PAINT FINISH 150mm X 32mm (6" X 1-1/4") METAL STUDS 25 GAUGE @ 600mm (24") O/C 150mm (6") ACOUSTIC BATT INSULATION 2 LAYERS 16mm (5/8") GYPSUM BOARD w/ PAINT FINISH 19mm X 89mm (1" X 4") SOLID WOOD STRAPPING @ 600mm (24") O/C 25mm (1") ARTICULATED WOOD PANELING. W1 CORRIDOR CORRIDOR W2 SUITE SUITE WINDOW SCHEDULE 8 9 10 11 12 13 14 15 16 17 3 ACOUSTIC STEEL SINGLE FRAME DETAILS 1:N.T.S. A0 2 ACOUSTIC STEEL PAIRED FRAME DETAILS 1:N.T.S. A0 18 19 20 O N A I O A O I A I O N

ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

Embed Size (px)

Citation preview

Page 1: ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

ID No. FROM TO NOMINALDIMENSIONS

DOOR

TYPE MAT FINISH FRR

FRAME

TYPE MAT FRAME FRRSYSTEM

STCHDWRGROUP NOTES

D1 VESTIBULE CORRIDOR 910 X 2115 A HM PT 45 A EXST PT N/A 49 5D2 418 THEATRE CORRIDOR 1525 X 2425 B WD STN/PT 45 B PM PT 45 51 1D3 419 STUDIO CORRIDOR 1525 X 2425 B WD STN/PT 45 B PM PT 45 51 1D4 419 STUDIO CORRIDOR N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TO BE REMOVEDD5 419 STUDIO CORRIDOR 915 X 2430 C HM PT 45 C PM PT 45 51 5D6 419 STUDIO KITCHEN 915X 2430 D EXST PT N/A EXST PT N/A 49 2 EXISTING DOOR & FRAME, NEW SEALSD7 419 STUDIO SOUND BOOTH 900 X 2045 E WD PT N/A PM PT N/A 49 3D8 418 THEATRE 419 STUDIO 910 X 2120 F WD PT N/A EXST PT N/A 49 4D9 418 THEATRE 419 STUDIO 910 X 2120 F WD PT N/A EXST PT N/A 49 4

RETAIN HINGES FOR REUSE WITH NEW DOOR.

DOOR HARDWARE MOUNTING HEIGHT TO MATCHEXISTING ADJACENT DOORS. CONTRACTOR TOCONFIRM ON SITE PRIOR TO DOOR FABRICATION.

TYPE B

±242

5

±1525

TYPE C

±243

0

±915

TYPE A

±211

5

±910

1000

1000

N/A NOT APPLICABLEEXST EXISTING

STN WOOD STAINPT PAINT

HM HOLLOW METALPM PRESSED METAL

915 X 2430

15

TYPE D

±243

0

±915

16 17 18

TYPE F

±212

0

±910

20

TYPE E

±204

5

±900

19

1000

1000

1000

DEFF

418THEATRE

419STUDIO

473CORRIDOR

457BALLET STUDIO

A11

A21

ID No. FROM TO NOMINALDIMENSIONS

WINDOW

TYPE MAT FRAME FRRNOTES

W1 SOUND BOOTH 418 THEATRE 1535 X 810 A FG PT N/AW2 SOUND BOOTH 419 STUDIO 905 X 905 B FG PT N/A

N/A NOT APPLICABLEEXST EXISTING

FG FIBER GLASSPT PAINT

1535

810

90590

5

TYPE A TYPE B

FRAME

TYPE MAT FRAME FRR

A FG PT N/AA FG PT N/A

GLASSSTC

3434

LAMINATED ACOUSTIC GLASSLAMINATED ACOUSTIC GLASS

SLIDER FIXED

CASEMENTHORIZONTAL SLIDER

REFERTODETAIL7 / A4

50RE

BATE

HEI

GHT

5050 REBATE WIDTH

11

15

C

C

1313

JAMB

DEP

TH

50

26

16

12

11

13

14

A. FRAME MUST BE INSTALLED AT FINISHED FLOOR HEIGHT. (DO NOT EMBED IN FLOOR).

B

1313

JAMB

DEP

TH

50

62

A. FRAME MUST BE INSTALLED AT FINISHED FLOOR HEIGHT. (DO NOT EMBED IN FLOOR).

50RE

BATE

HEI

GHT

5050 50REBATE (2)REBATE (1) 16

8

10

2

1

3

6

5

4

7

1

3

2 9

1

4

BAA

C

C

50

8

216

NOTESPRESSED STEEL ACOUSTIC FRAME.

FIRE RATED PERIMETER NEOPRENE SEAL.

PERIMETER SMOKE SEAL.

INTUMESCENT STRIP.

HINGES.

INTUMESCENT HINGE PROTECTION.

HINGE REINFORCEMENT, FACTORY WELDED IN FRAME.

ACOUSTIC ASTRAGAL FASTENED TO THE PUSH SIDE OF THE INACTIVE DOOR.LEAF.

BRACKET AND ADDITIONAL PERIMETER SEALS TO BE FITTED AND FASTENEDTO HEADER AT SITE.

12.7mm HIGH STEPPED ACOUSTIC THRESHOLD 127mm WIDTH, TO BEINSTALLED ON FINISHED FLOOR.

ACOUSTIC PERIMETER SEAL TO BE FITTED AND FASTENED TO JAMBS,MULLION, AND HEAD.

ACOUSTIC NEOPRENE AT HEADER ONLY.

INSTALL SECONDARY PERIMETER ACOUSTIC SEAL FOR STC TO BE FITTEDAND FASTENED TO JAMBS AND HEAD.

6mm HIGH FLAT ACOUSTIC THRESHOLD 127mm WIDTH, TO BE INSTALLED ONFINISHED FLOOR.

TYPE A - NEW HOLLOW METAL DOOR & EXISTING DOOR FRAME.

TYPE B - NEW ACOUSTIC WOOD DOUBLE DOORS & NEW PRESSED METALDOOR FRAME, STAIN WOOD FINISH ON CORRIDOR SIDE, BLACK PAINT FINISHON SUITE SIDE.

TYPE C - NEW HOLLOW METAL DOOR & NEW PRESSED METAL DOOR FRAME.

TYPE D - EXISTING DOOR & DOOR FRAME WITH NEW ACOUSTIC HEAD & JAMBSEALS.

TYPE F - NEW ACOUSTIC WOOD DOOR & NEW PRESSED METAL DOOR FRAME.

TYPE E - NEW ACOUSTIC WOOD DOORS & EXISTING DOOR FRAME.

1

2

3

4

5

6

7

1 KEY PLAN - SECOND LEVEL1:200A0

OTTAWA, ONTARIO DRAWING / DESSIN

BUSINESS ENTITY / NUMÉRO DE L'ENTITÉBUILDING NUMBER / NUMÉRO DU BÂTIMENT

PROJECT NO. / NUMÉRO DE PROJET

SHEET NO. / FEUILLE No.

CONSULTANT / EXPERT-CONSEIL

CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LAVILLE D'OTTAWA ET TOUT DROIT D'AUTEUR ESTRÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONTÀ DES FINS D'ESTIMATION SEULEMENT. ILINCOMBE À CHAQUE ENTREPRENEUR,SOUS-CONTRACTANT OU CONSULTANT DEVÉRIFIER TOUTES LES DIMENSIONS ET LESCONDITIONS SUR LE CHANTIER. VEUILLEZINFORMER LE PROPRIÉTAIRE DE TOUTEERREUR OU OMISSION AVANT D'ENTAMER LESTRAVAUX. NE DRESSEZ PAS LES PLANS ÀL'ÉCHELLE.

CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL

PROJECT / LOCATION / PROJET / ENDROIT

ARCHITECT / ARCHITECTE

THIS DRAWING IS THE PROPERTY OF THE CITYOF OTTAWA AND ALL COPYRIGHT ISRESERVED.DIMENSIONS ON DRAWING ARE FORESTIMATING PURPOSES ONLY. IT IS THERESPONSIBILITY OF EACH CONTRACTOR ANDSUB-CONTRACTOR OR CONSULTANT TO CHECKAND VERIFY ALL DIMENSIONS AND CONDITIONSON SITE. NOTIFY OWNER OF ANY ERRORS OROMISSIONS PRIOR TO COMMENCING THEWORK. DO NOT SCALE THE DRAWINGS.

(Y/M/D)(A/M/J)MILESTONE / FAIT SAILLANT DATE:

FOR / POUR

1A1.1

SHEET NUMBER

DETAIL NUMBER

DRAWING TITLESCALE:

NUMBER/NUMÉRO

INITIALSINITIALES

PLANNING AND INFRASTRUCTURE PORTFOLIOINFRASTRUCTURE SERVICES DEPARTMENT

DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH________________________________________________________________

PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTUREDÉPARTEMENT DES SERVICES D'INFRASTRUCTURE

DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS

Fax.: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected].: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected]

TWSH

TWSH

TWSH

2014/04/15

2014/03/31

6

5

4

3

2

1

PARKS, RECREATION & CULTURAL SERVICES

DESIGN & CONSTRUCTION - BUILDINGSCULTURAL & HERITAGE SERVICES

TWSH

ISSUED FOR PERMIT

ISSUED FOR 95% CLIENT REVIEW

2014/03/11ISSUED FOR 60% CLIENT REVIEW

TWSH

AS INDICATEDJLG

CR009876

BE1029 BU1000 A0

KEY PLAN / SCHEDULESTITLE PAGE

2 DALY AVENUE

SECOND FLOORARTS COURTCITY OF OTTAWA

DOOR SCHEDULE

A0 TITLE PAGE / KEY PLAN / SCHEDULESA1 457 BALLET STUDIO & 473 CORRIDOR PLAN ENLARGEMENT &

DETAILSA2 418 THEATRE & 419 STUDIO PLAN ENLARGEMENT & DETAILSA3 419 STUDIO INTERIOR ELEVATIONS & DETAILSA4 SOUND BOOTH PLAN ENLARGEMENT, INTERIOR ELEVATIONS, &

DETAILS

DRAWING LIST

A. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDING PERMIT, CONTRACTORIS RESPONSIBLE FOR ALL OTHER REQUIREMENTS FOR AUTHORITIES HAVINGJURISDICTION, INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE.

B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALL OTHER DRAWINGS &SPECIFICATIONS.

C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALL DIMENSIONS ONSITE.

D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENT REPRESENTATIVE INWRITING OF ANY DISCREPANCIES OF DIMENSIONS, MATERIALS, AND/ORCONDITIONS.

E. UNLESS OTHERWISE INDICATED AS EXISTING, ALL MATERIALS ARE NEW ANDTO BE SUPPLIED & INSTALLED AS PART OF THIS CONTRACT.

F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURN TO THE DESIREDEND PLACE BUT WILL NOT BE RESPONSIBLE FOR INSTALLATIONS.

G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY A CERTIFIED ELECTRICIAN.

H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TO REMAIN.

I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHEN PROCEEDINGWITH PROJECT WORK.

J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECT WORK.

K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES. CONTRACTOR TOASSUME 10% REPLACEMENT.

L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES AS PER MASTERPAINTERS INSTITUTE (MPI) PAINTING STANDARD. COORDINATE WITH CLIENTREPRESENTATIVE FOR APPROVED COLOUR SCHEME.

M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPI PAINTING STANDARD.COORDINATE WITH DEPARTMENTAL REPRESENTATIVE FOR APPROVEDCOLOUR SCHEME.

GENERAL NOTES

CONSTRUCTION ASSEMBLIES

ACOUSTIC AND FLOORING UPGRADES TO THE ARTS COURT

16mm (5/8") PLASTER/GYPSUM FINISH200mm (8") CONCRETE BLOCK19mm X 89mm (1" X 4") WOOD STRAPPING.25mm (1") ARTICULATED WOOD PANELING.

1 LAYER 16mm (5/8") GYPSUM w/ PAINT FINISH150mm X 32mm (6" X 1-1/4") METAL STUDS 25 GAUGE @ 600mm (24") O/C150mm (6") ACOUSTIC BATT INSULATION2 LAYERS 16mm (5/8") GYPSUM BOARD w/ PAINT FINISH19mm X 89mm (1" X 4") SOLID WOOD STRAPPING @ 600mm (24") O/C25mm (1") ARTICULATED WOOD PANELING.

W1

CORR

IDOR

CORR

IDOR

W2

SUIT

ESU

ITE

WINDOW SCHEDULE

8

9

10

11

12

13

14

15

16

17

3 ACOUSTIC STEEL SINGLE FRAME DETAILS1:N.T.S.A0

2 ACOUSTIC STEEL PAIRED FRAME DETAILS1:N.T.S.A0

18

19

20

ON

A

IO A OIA

ION

Page 2: ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

21 21

12

3

3

4

4

7

18

1818

18

181818

18 18

18

18

18

18

18

18

3

2000

EQEQ

2000

EQEQ

17

17

3

3

3

473CORRIDOR

457BALLET STUDIO

65

3

3

C7

C6

C5 C4

C10 C9

C3

C2

C1C8

10601060

A12

A13

24920

17

17

17

17

3580

4621

1590

15650

8090

19 20

20

20

20

21 21

21

A12

20

20

20

±2770

2000

2000

2000

2000

8

50 M

IN.

OVER

LAP

16

16

±250

12

13

300

150

10

11

9

150

14

15

±200

2 19

19

NOTE: TYPICAL FOR 473 CORRIDOR

ID No. NOTESHIEGHT WIDTH FABRIC COLOR FULLNESS LINING TOPFINISH

SIDEFINISH

BOTTOMFINISH TRACK

C1C2C3C4C5C6C7C8C9

C10

5436 5640823018307925762085353810792515251525

SV BLK 0% N/A

BOLBOL

WGS H HC EXST

NEWNEW

543654365436543654365436543654365436

SVSVSVSVSVSVSVSVSV

BLKBLKBLKBLKBLKBLKBLKBLKBLK

0%0%0%0%0%0%0%0%0%

N/AN/AN/AN/AN/AN/AN/A

WGSWGSWGSWGSWGSWGSWGSWGSWGS

HHHHHHHHH

HCHCHCHCHCHCHCHCHC

EXSTEXSTEXSTEXSTEXSTEXSTEXST

SV SYNTHETIC VELOURBLK BLACKWGS WEBBING, GROMMETS, S-HOOKS

H HEM 50mmHC HEM WITH CHAINEXST EXISTING

BOL BLACK-OUT LINING

A. REMOVE AND DISPOSE OF EXISTING CURTAINS ALL EXISTING CURTAIN TRACKS ARE WALK ALONG OPERATIONS.B. PRIOR TO INSTALLING NEW CURTAINS, INSPECT, LUBRICATE ALL MOVING PARTS.C. REPLACE DAMAGED AND WORN PARTS AS REQUIRED.

WALK ALONG TRACK FUNCTIONWALK ALONG TRACK FUNCTION

1 PLAN ENLARGEMENT - 457 BALLET STUDIO & 473 CORRIDOR1:50A1

OTTAWA, ONTARIO DRAWING / DESSIN

BUSINESS ENTITY / NUMÉRO DE L'ENTITÉBUILDING NUMBER / NUMÉRO DU BÂTIMENT

PROJECT NO. / NUMÉRO DE PROJET

SHEET NO. / FEUILLE No.

CONSULTANT / EXPERT-CONSEIL

CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LAVILLE D'OTTAWA ET TOUT DROIT D'AUTEUR ESTRÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONTÀ DES FINS D'ESTIMATION SEULEMENT. ILINCOMBE À CHAQUE ENTREPRENEUR,SOUS-CONTRACTANT OU CONSULTANT DEVÉRIFIER TOUTES LES DIMENSIONS ET LESCONDITIONS SUR LE CHANTIER. VEUILLEZINFORMER LE PROPRIÉTAIRE DE TOUTEERREUR OU OMISSION AVANT D'ENTAMER LESTRAVAUX. NE DRESSEZ PAS LES PLANS ÀL'ÉCHELLE.

CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL

PROJECT / LOCATION / PROJET / ENDROIT

ARCHITECT / ARCHITECTE

THIS DRAWING IS THE PROPERTY OF THE CITYOF OTTAWA AND ALL COPYRIGHT ISRESERVED.DIMENSIONS ON DRAWING ARE FORESTIMATING PURPOSES ONLY. IT IS THERESPONSIBILITY OF EACH CONTRACTOR ANDSUB-CONTRACTOR OR CONSULTANT TO CHECKAND VERIFY ALL DIMENSIONS AND CONDITIONSON SITE. NOTIFY OWNER OF ANY ERRORS OROMISSIONS PRIOR TO COMMENCING THEWORK. DO NOT SCALE THE DRAWINGS.

(Y/M/D)(A/M/J)MILESTONE / FAIT SAILLANT DATE:

FOR / POUR

1A1.1

SHEET NUMBER

DETAIL NUMBER

DRAWING TITLESCALE:

NUMBER/NUMÉRO

INITIALSINITIALES

PLANNING AND INFRASTRUCTURE PORTFOLIOINFRASTRUCTURE SERVICES DEPARTMENT

DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH________________________________________________________________

PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTUREDÉPARTEMENT DES SERVICES D'INFRASTRUCTURE

DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS

Fax.: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected].: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected]

TWSH

TWSH

TWSH

2014/04/15

2014/03/31

6

5

4

3

2

1

PARKS, RECREATION & CULTURAL SERVICES

DESIGN & CONSTRUCTION - BUILDINGSCULTURAL & HERITAGE SERVICES

TWSH

ISSUED FOR PERMIT

ISSUED FOR 95% CLIENT REVIEW

2014/03/11ISSUED FOR 60% CLIENT REVIEW

TWSH

AS INDICATEDJLG

CR009876

BE1029 BU1000 A1

PLAN ENLARGEMENT & DETAILS& 473 CORRIDOR457 BALLET STUDIO

2 DALY AVENUE

SECOND FLOORARTS COURTCITY OF OTTAWA

REMOVE SHOE MOLD PRIOR TO ABATEMENT WORKSPECIFIED AND DETAILED BY DST CONSULTINGENGINEERS. REFER TO APPENDIX B. CONTRACTOR TOPATCH & REPAIR EXISTING SUBSTRATE FLOOR TO RECEIVENEW FORBO SHEET GOODS FLOORING.

INSTALL NEW FORBO SHEET GOODS FLOORING INCORRIDOR. REFER TO NOTE 17 FOR LOCATION OFSEAMS/WELDS.

TYPICAL FOR CORRIDOR 473. INSTALL NEW SHOE MOLD.PRIME & PAINT. REFER TO DETAIL 3/A1.

TYPICAL FOR SMALL CORRIDOR - INSTALL NEW RUBBERBASE MOLD.

EXISTING DANCE SHEET FLOORING TO BE REMOVED,ROLLED UP FOR STORAGE AND TURNED OVER TO CLIENT.

NEW DANCE PERFORMANCE SHEET FLOORING, TAPE ALLSEAMS AS PER MANUFACTURER'S RECOMMENDATIONS.CONTRACTOR TO PROVIDE FLOOR STORAGE CART FORFOUR (4) ROLLS & 25 ROLLS OF TAPE - REFER TOSPECIFICATIONS SECTION 09 65 16 - RESILIENT SHEETFLOORING.

EXISTING BLEACHER SYSTEM TO BE TEMPORARILYREMOVED BY CLIENT.

EXISTING WINDOW ALCOVE SUBSTRATE.

EXISTING WINDOW TO REMAIN.

FASTEN NEW CURTAIN TRACK SECURING CLAMP TOEXISTING WINDOW ALCOVE SUBSTRATE AS PERMANUFACTURER RECOMMENDATIONS.

NEW CURTAIN TRACK SYSTEM TO MATCH EXISTINGINSTALLED WALK ALONG SYSTEM.

NEW 19mm THICK GIS PLYWOOD VALANCE, HEIGHT ASREQUIRED TO OVERLAP CURTAIN BY 50mm MIN., FLATBLACK PAINT FINISH ALL SIDES.

NEW BLACK-OUT CURTAIN - REFER TO CURTAIN SCHEDULE.

FILL DEFECTS & PREPARE SURFACE OF EXISTING WOODBASE BOARD, PRIME & PAINT FINISH.

INSTALL NEW SOLID WOOD QUATER ROUND (SHOE MOLD)TO MATCH EXISTING PROFILE ONCE ABATEMENT WORKHAS BEEN COMPLETED. PRIME & PAINT ALL SIX SIDESPRIOR TO INSTALLATION.

STEEL ANGLE VALANCE SUPPORT BRACKETS FASTENEDTO SIDE WALLS OF ALCOVE. FLAT BLACK PAINT FINISH.

FOR SHEET GOODS FLOORING LOCATE SEAMS/WELDS ASINDICATED BY DASHED LINE.

TYPICAL - PROVIDE NEW TRANSITION STRIP BETWEEN NEWAND EXISTING FLOORING.

NEW DANCE SHEET FLOORING, TO BE CONFIGURED INTWO MAIN FLOOR AREAS: PRIMARY DANCE FLOOR AREA &SECONDARY FLOOR AREA UNDER BLEACHERS. SEAMSEPARATING BOTH PRIMARY & SECONDARY FLOOR AREASTO BE LOCATED CLEAR OF BLEACHERS.

PROPOSED NEW DANCE SHEET FLOORING TAPED SEAMLOCATION.

TAPED EDGE OF DANCE SHEET FLOORING.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

NOTES

15

2 WINDOW ALCOVE1:5A1

16

3 BASEBOARD DETAIL1:2A1

17

18

GENERAL NOTESA. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDING

PERMIT, CONTRACTOR IS RESPONSIBLE FOR ALL OTHERREQUIREMENTS FOR AUTHORITIES HAVING JURISDICTION,INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE.

B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALLOTHER DRAWINGS & SPECIFICATIONS.

C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALLDIMENSIONS ON SITE.

D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENTREPRESENTATIVE IN WRITING OF ANY DISCREPANCIES OFDIMENSIONS, MATERIALS, AND/OR CONDITIONS.

E. UNLESS OTHERWISE INDICATED AS EXISTING, ALLMATERIALS ARE NEW AND TO BE SUPPLIED & INSTALLED ASPART OF THIS CONTRACT.

F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURNTO THE DESIRED END PLACE BUT WILL NOT BERESPONSIBLE FOR INSTALLATIONS.

G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY ACERTIFIED ELECTRICIAN.

H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TOREMAIN.

I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHENPROCEEDING WITH PROJECT WORK.

J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECTWORK.

K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES.CONTRACTOR TO ASSUME 10% REPLACEMENT.

L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES ASPER MASTER PAINTERS INSTITUTE (MPI) PAINTINGSTANDARD. COORDINATE WITH CLIENT REPRESENTATIVEFOR APPROVED COLOUR SCHEME.

M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPIPAINTING STANDARD. COORDINATE WITH DEPARTMENTALREPRESENTATIVE FOR APPROVED COLOUR SCHEME.

19

20

CURTAIN SCHEDULE

ON

A

IO A OIA

ION

21

Page 3: ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

DD CC BB

D4D3D2

D5

D6

D9

D8

D1

D7

W2W1

A31

A22&3

A32

A34

A33

418THEATRE

419STUDIO

SOUNDBOOTH

A22&3

A22&4 A2

2&3

A41

17

A39

20

20

19

A26

21

3a

4a

31

31

31

38

40

32 32

32

3

2

W1

1

CORRIDOR

±320

5

418THEATRE

OR419

STUDIO

W2

VARI

ES F

ROM

2134

TO

2438

A.F

.F.

3

W1

5

4

1

CORRIDOR

418THEATRE

OR419

STUDIO

18

±794

A27

A25

SIM4

W2

W1

3

419STUDIO CORRIDOR

NOTE:REFER TO DETAILS 7 & 8 /A3 FOR WOOD PANELINGCONSTRUCTION.

±325

5

A25

SIM

1

A37

860

±61023

22

22

24

24

26

26

27

25

±610

±760

±560

2828

DD

75

28

75

25

30

30

37

25

28

28

28

37

37

NOTE: CONTRACTOR TO VERIFYROUGH OPENING DIMENSIONSPRIOR TO HATCH FABRICATION

7

8

10

11

12

1314

10

15

16

6

W1

W2

CORRIDOR

418THEATRE

OR419

STUDIO

W2

1

33

35

36

CORRIDOR

418THEATRE

OR419

STUDIO

34

88

3939

1 PLAN ENLARGEMENT - 418 THEATRE & 419 CONFERENCE1:50A2

OTTAWA, ONTARIO DRAWING / DESSIN

BUSINESS ENTITY / NUMÉRO DE L'ENTITÉBUILDING NUMBER / NUMÉRO DU BÂTIMENT

PROJECT NO. / NUMÉRO DE PROJET

SHEET NO. / FEUILLE No.

CONSULTANT / EXPERT-CONSEIL

CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LAVILLE D'OTTAWA ET TOUT DROIT D'AUTEUR ESTRÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONTÀ DES FINS D'ESTIMATION SEULEMENT. ILINCOMBE À CHAQUE ENTREPRENEUR,SOUS-CONTRACTANT OU CONSULTANT DEVÉRIFIER TOUTES LES DIMENSIONS ET LESCONDITIONS SUR LE CHANTIER. VEUILLEZINFORMER LE PROPRIÉTAIRE DE TOUTEERREUR OU OMISSION AVANT D'ENTAMER LESTRAVAUX. NE DRESSEZ PAS LES PLANS ÀL'ÉCHELLE.

CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL

PROJECT / LOCATION / PROJET / ENDROIT

ARCHITECT / ARCHITECTE

THIS DRAWING IS THE PROPERTY OF THE CITYOF OTTAWA AND ALL COPYRIGHT ISRESERVED.DIMENSIONS ON DRAWING ARE FORESTIMATING PURPOSES ONLY. IT IS THERESPONSIBILITY OF EACH CONTRACTOR ANDSUB-CONTRACTOR OR CONSULTANT TO CHECKAND VERIFY ALL DIMENSIONS AND CONDITIONSON SITE. NOTIFY OWNER OF ANY ERRORS OROMISSIONS PRIOR TO COMMENCING THEWORK. DO NOT SCALE THE DRAWINGS.

(Y/M/D)(A/M/J)MILESTONE / FAIT SAILLANT DATE:

FOR / POUR

1A1.1

SHEET NUMBER

DETAIL NUMBER

DRAWING TITLESCALE:

NUMBER/NUMÉRO

INITIALSINITIALES

PLANNING AND INFRASTRUCTURE PORTFOLIOINFRASTRUCTURE SERVICES DEPARTMENT

DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH________________________________________________________________

PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTUREDÉPARTEMENT DES SERVICES D'INFRASTRUCTURE

DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS

Fax.: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected].: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected]

TWSH

TWSH

2014/03/31

6

5

4

3

2

1

PARKS, RECREATION & CULTURAL SERVICES

DESIGN & CONSTRUCTION - BUILDINGSCULTURAL & HERITAGE SERVICES

TWSH

ISSUED FOR 95% CLIENT REVIEW

2014/03/11ISSUED FOR 60% CLIENT REVIEW

TWSH

AS INDICATEDJLG

CR009876

BE1029 BU1000 A2

PLAN ENLARGEMENT & DETAILS418 THEATRE & 419 STUDIO

2 DALY AVENUE

SECOND FLOORARTS COURTCITY OF OTTAWA

A2 1:20

DEMO2A2 1:20

RATED DOOR3A2 1:20

FULL INFILL4

TEMPORARILY REMOVE EXISTING SUSPENDED CEILING ASREQUIRED TO PERMIT REMOVAL OF DOOR & DOOR FRAME.REINSTATE AFTER WORK IS COMPLETED. REPLACE DAMAGEDCOMPONENTS, CONTRACTOR TO ASSUME 10%.

EXISTING WOOD DOOR, TRANSOM AND FRAME TO BEREMOVED.

EXISTING RAISED FLOOR.

NEW WOOD PANELING TO MATCH EXISTING ADJACENT INMATERIALS PATTERN AND COLOUR.

NEW ACOUSTICALLY RATED DOOR AND FRAME ASSEMBLY.

EXISTING 200mm (8") CONCRETE BLOCK.

EXISTING 16mm (5/8") PLASTER/GYPSUM FINISH.

CONTINUOUS BEAD OF SEALANT AROUND PERIMETER.

CONTINUOUS NEOPRENE GASKET MATERIAL.

METAL 'J'-TRIM AT PERIMETER OF W2 - INFILL PARTITION.

1 LAYER OF 16mm (5/8") TYPE 'X' GYPSUM TO ALIGN FACE WITHADJACENT FINISHED SURFACE.

150mm X 32mm METAL TRACK/STUD.

150mm ACOUSTICAL BATT INSULATION.

2 LAYERS OF 16mm (5/8") TYPE 'X' GYPSUM.

19mm X 89mm WOOD STRAPPING.

FINISHED WOOD PANELING TO ALIGN WITH ADJACENTEXISTING WOOD PANELING.

CONTRACTOR TO COORDINATE WITH CLIENT FOR REMOVALAND REINSTATEMENT OF EXISTING CABLE BY CLIENT TOFACILITATE REMOVALS AND NEW CONSTRUCTION.

MODIFY/RECONSTRUCT SLOPED THRESHOLD TOACCOMMODATE NEW ACOUSTIC DOOR THRESHOLD. PAINTFINISH - SAFETY YELLOW.

DOOR D4 & DOOR FRAME TO BE REMOVED, OPENING TO BEIN-FILLED WITH W2 WALL ASSEMBLY, REFER TO A0CONSTRUCTION ASSEMBLIES.

DASHED LINE INDICATES EXTENT OF EXISTING BULKHEADCEILING ABOVE.

FABRICATE & INSTALL LARGE ACOUSTIC HATCH IN LOWERWALL BELOW SEATING. REFER TO DETAIL 6/A2.

EXISTING PARTITION.

PROVIDE 50 mm X 50 mm X 6 mm STEEL LINTEL TO EXTENDBEYOND OPENING 100mm ON EACH SIDE.

TYPICAL FILL IRREGULAR VOIDS WITH ACOUSTIC BATTINSULATION AROUND PERIMETER OF OPENING PRIOR TOENCLOSING WITH PLYWOOD.

25 mm THICK VISCOELASTIC MEMORY FOAM LAMINATED TO 19mm PLYWOOD TO FRAME OPENING.

19 mm PLYWOOD PAINTED BLACK ALL SIDES FITTED TOOPENING, FULL DEPTH OF OPENING.

DE-MOUNTABLE ACCESS HATCH: 25 mm THICK VISCOELASTICMEMORY FOAM LAMINATED TO 19 mm PLYWOOD PAINTEDBLACK ALL SIDES.

PLASTIC THUMB SCREWS FOR MOUNTING AND DE-MOUNTINGACCESS HATCH COVER.

CABLE ROUTING TO BE 'SANDWICHED' BETWEEN TWOSEPARATE LAYERS FO VISCOELASTIC FOAM FOR ACOUSTICALSEAL.

T-NUT SECURED THROUGH BACK OF PLYWOOD TO ACCEPTTHUMB SCREWS.

REMOVE EXISTING DOOR, DOOR FRAME TO REMAIN. RETAINEXISTING HARDWARE AND TURN OVER TO CLIENT. (FORDOORS D8 & D9 REUSE EXISTING HINGES FOR NEW DOOR).

REMOVE EXISTING DOOR AND DOOR FRAME. RETAIN EXISTINGHARDWARE AND TURN OVER TO CLIENT. INFILL TRANSOMAREA AS INDICATED. INSTALL NEW ACOUSTICALLY RATEDDOOR AND FRAME.

x2 - 150mm X 32mm (6" X 1-1/4") METAL STUDS 25 GAUGEHEADER.

150mm (6") ACOUSTIC BATT INSULATION.

PRESSED METAL ACOUSTIC DOOR FRAME.

ACOUSTIC DOOR. REFER TO A0 / DOOR SCHEDULE.

EXAMPLE OF CONTROL CABLES TO BE RUN BETWEEN FOAM OFLARGE ACOUSTIC PANEL SHOWN FOR INTENT ONLY.

REMOVE EXISTING DOOR AND FRAME. RETAIN EXISTINGHARDWARE AND TURN OVER TO CLIENT FOR REUSE.

METAL CORNER BEAD.

PROVIDE NEW RETROFITTED ACOUSTIC SEALS AND

HARDWARE TO EXISTING DOOR AND FRAME.1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

NOTES

17

18

19

20

21

GENERAL NOTESA. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDING PERMIT,

CONTRACTOR IS RESPONSIBLE FOR ALL OTHERREQUIREMENTS FOR AUTHORITIES HAVING JURISDICTION,INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE.

B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALL OTHERDRAWINGS & SPECIFICATIONS.

C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALLDIMENSIONS ON SITE.

D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENTREPRESENTATIVE IN WRITING OF ANY DISCREPANCIES OFDIMENSIONS, MATERIALS, AND/OR CONDITIONS.

E. UNLESS OTHERWISE INDICATED AS EXISTING, ALL MATERIALSARE NEW AND TO BE SUPPLIED & INSTALLED AS PART OF THISCONTRACT.

F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURN TOTHE DESIRED END PLACE BUT WILL NOT BE RESPONSIBLE FORINSTALLATIONS.

G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY A CERTIFIEDELECTRICIAN.

H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TOREMAIN.

I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHENPROCEEDING WITH PROJECT WORK.

J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECT WORK.

K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES.CONTRACTOR TO ASSUME 10% REPLACEMENT.

L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES ASPER MASTER PAINTERS INSTITUTE (MPI) PAINTING STANDARD.COORDINATE WITH CLIENT REPRESENTATIVE FOR APPROVEDCOLOUR SCHEME.

M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPIPAINTING STANDARD. COORDINATE WITH DEPARTMENTALREPRESENTATIVE FOR APPROVED COLOUR SCHEME.

23

6 THEATRE WALL LARGE ACOUSTIC HATCH1:10A2 A2 1:5

JOINT PLAN DETAIL5

24

25

26

27

28

29

30

A2 1:20

DOOR HEADER7

31

22

32

33

34

35

36

ON

A

IO A OIA

ION

37

38

39

40

Page 4: ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

419STUDIO

1220 1585 1585 1585 1585 1585 1585 1585 1585 1545

100

100

1111

6

1220

1220

15

D4 D3

419STUDIO

1570 1585 1585 1585 1585 1585 1585 1585 1585 1220

1220

100

1220

100

91310 1113

6

15

A37

12

A37

SIM238

262626

D5D6

1060 1585 8851290

1220

100

1220

100

419STUDIO

10

A38

SIM 14

66

15

1130 1585

±5500

1524

±535

±206

017

A39

16

D9 D8

W2

1305 1160 1665 113511601665

100

1220

100

419STUDIO

66

1220

775

790

775

15

790

25 25

4

5

3

5

100

2

6

1

5

3

3

5

7

5

6

6

2

7

1

419STUDIO

A38

±322

5

6

EQ EQ

23

±1610

419STUDIO

CORRIDOR

5025

50 667 5025

50 667 5025

50

38

W2W1 W1

24

90

25

24

25 25

2122 18 19 206 1419

STUDIO

4 INTERIOR ELEVATION - NORTH - 419 STUDIO1:50A3

1 INTERIOR ELEVATION - SOUTH - 419 STUDIO1:50A3

OTTAWA, ONTARIO DRAWING / DESSIN

BUSINESS ENTITY / NUMÉRO DE L'ENTITÉBUILDING NUMBER / NUMÉRO DU BÂTIMENT

PROJECT NO. / NUMÉRO DE PROJET

SHEET NO. / FEUILLE No.

CONSULTANT / EXPERT-CONSEIL

CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LAVILLE D'OTTAWA ET TOUT DROIT D'AUTEUR ESTRÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONTÀ DES FINS D'ESTIMATION SEULEMENT. ILINCOMBE À CHAQUE ENTREPRENEUR,SOUS-CONTRACTANT OU CONSULTANT DEVÉRIFIER TOUTES LES DIMENSIONS ET LESCONDITIONS SUR LE CHANTIER. VEUILLEZINFORMER LE PROPRIÉTAIRE DE TOUTEERREUR OU OMISSION AVANT D'ENTAMER LESTRAVAUX. NE DRESSEZ PAS LES PLANS ÀL'ÉCHELLE.

CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL

PROJECT / LOCATION / PROJET / ENDROIT

ARCHITECT / ARCHITECTE

THIS DRAWING IS THE PROPERTY OF THE CITYOF OTTAWA AND ALL COPYRIGHT ISRESERVED.DIMENSIONS ON DRAWING ARE FORESTIMATING PURPOSES ONLY. IT IS THERESPONSIBILITY OF EACH CONTRACTOR ANDSUB-CONTRACTOR OR CONSULTANT TO CHECKAND VERIFY ALL DIMENSIONS AND CONDITIONSON SITE. NOTIFY OWNER OF ANY ERRORS OROMISSIONS PRIOR TO COMMENCING THEWORK. DO NOT SCALE THE DRAWINGS.

(Y/M/D)(A/M/J)MILESTONE / FAIT SAILLANT DATE:

FOR / POUR

1A1.1

SHEET NUMBER

DETAIL NUMBER

DRAWING TITLESCALE:

NUMBER/NUMÉRO

INITIALSINITIALES

PLANNING AND INFRASTRUCTURE PORTFOLIOINFRASTRUCTURE SERVICES DEPARTMENT

DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH________________________________________________________________

PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTUREDÉPARTEMENT DES SERVICES D'INFRASTRUCTURE

DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS

Fax.: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected].: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected]

TWSH

TWSH

TWSH

2014/04/15

2014/03/31

6

5

4

3

2

1

PARKS, RECREATION & CULTURAL SERVICES

DESIGN & CONSTRUCTION - BUILDINGSCULTURAL & HERITAGE SERVICES

TWSH

ISSUED FOR PERMIT

ISSUED FOR 95% CLIENT REVIEW

2014/03/11ISSUED FOR 60% CLIENT REVIEW

TWSH

AS INDICATEDJLG

CR009876

BE1029 BU1000 A3 INTERIOR ELEVATIONS & DETAILS419 STUDIO

2 DALY AVENUE

SECOND FLOORARTS COURTCITY OF OTTAWA

2 INTERIOR ELEVATION - EAST - 419 STUDIO1:50A3

3 INTERIOR ELEVATION - WEST - 419 STUDIO1:50A3

NOTES

5 PANEL BASE DETAIL1:1A3

6 PANEL PLAN DETAIL1:1A3

EXISTING WALL (ASSUMED CONDITION)- METAL FURRING CHANNELS- EXPANDED METAL MESH- ROUGH COAT PLASTER FINISH (ROUGH TEXTURE)

EXISTING WOOD PANELING.

ACOUSTIC PANEL MOUNTING CLIP.

ACOUSTIC PANEL LEVELING CLIP.

ACOUSTIC PANEL WALL CLIP.

WALL MOUNTED ACOUSTIC PANEL. TYPICAL PANEL SIZE1585mm w X 1220mm h UNLESS OTHERWISE NOTED.PROVIDE CUT OUTS IN PANELS AS REQUIRED TOACCOMMODATE SURFACE MOUNTED FIXTURES. REFER TODETAILS 5 & 6 / A3..

ALIGN BUTT JOINT WITH CENTER OF WOOD PANELINGSPAR BELOW (±1585mm). CONTRACTOR TO VERIFYDIMENSIONS AND PROVIDE MEASURED SHOP DRAWINGSFOR REVIEW PRIOR TO ORDER.

RECONSTRUCT PANELING ABOVE DOOR FRAME AFTERDOOR INSTALLATION. PAINT FINISH.

FILL CAVITY IN WALL WITH ACOUSTIC BATT INSULATIONAND SEAL SURFACE WITH GYPSUM.

EXISTING EXIT LIGHT TO REMAIN.

EXISTING EMERGENCY LIGHT TO REMAIN.

EXISTING EMERGENCY STROBE TO REMAIN.

ENSURE RECESSED BOX IS DECOMMISSIONED. INFILL WITHACOUSTIC BATT INSULATION AND SEAL SURFACE WITHGYPSUM.

CONTRACTOR TO COORDINATE WITH CLIENT FORREMOVAL AND REINSTATEMENT OF CABLE BY CLIENT TOFACILITATE REMOVALS AND NEW CONSTRUCTION.

EXISTING ACRYLIC ILUMINATED T-BAR CEILING GRID TOREMAIN.

NEW 5.50m W X 2.06m H (18'-0" W X 6'-9" H) WHITEPROJECTION SURFACE SYSTEM.

PROPOSED LOCATION FOR PROJECTION SURFACE SYSTEMAPPLIED ROLL BUTT JOINT SEAM. CONFIRM WITH CLIENT.

19mm X 89mm WOOD FURRING @ 600mm O.C. MIN.

19mm THICK MEDIUM DENSITY OVERLAY (SIGN BOARD).PAINT FINISH.

ADHERE PROJECTION SURFACE LAMINATE TO MEDIUMDENSITY OVERLAY (SIGN BOARD) AS PER PROJECTIONSCREEN MANUFACTURER RECOMMENDATIONS.

FRAME EDGES (4) OF PROJECTION SURFACE WITH 19mmALUMINUM J-TRIM, ANODIZED FINISH.

DASHED LINE INDICATES EXISTING MECHANICAL BULKHEADCEILING ABOVE.

DOOR D4 AND DOOR FRAME TO BE REMOVED, OPENING TOBE IN-FILLED WITH W2, REFER TO A0 CONSTRUCTIONASSEMBLIES.

GIS PAINT GRADE PLYWOOD C/W 3 mm HARDWOOD EDGESTRIPS. DEPTH TO MATCH EXISTING.

VERTICAL PANEL SPAR FROM PAINT GRADE SOLIDLUMBER.

EXISTING VENTILATION GRILLES

1

2

3

4

5

6

7

GENERAL NOTES

7 DOORWAY INFILL 1:20A3

8

A3 1:10

DOOR INFILL - WOOD PANEL RECONSTRUCTION PLAN8

9

10

11

12

13

14

15

A. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDINGPERMIT, CONTRACTOR IS RESPONSIBLE FOR ALL OTHERREQUIREMENTS FOR AUTHORITIES HAVING JURISDICTION,INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE.

B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALLOTHER DRAWINGS & SPECIFICATIONS.

C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALLDIMENSIONS ON SITE.

D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENTREPRESENTATIVE IN WRITING OF ANY DISCREPANCIES OFDIMENSIONS, MATERIALS, AND/OR CONDITIONS.

E. UNLESS OTHERWISE INDICATED AS EXISTING, ALLMATERIALS ARE NEW AND TO BE SUPPLIED & INSTALLED ASPART OF THIS CONTRACT.

F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURNTO THE DESIRED END PLACE BUT WILL NOT BERESPONSIBLE FOR INSTALLATIONS.

G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY ACERTIFIED ELECTRICIAN.

H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TOREMAIN.

I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHENPROCEEDING WITH PROJECT WORK.

J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECTWORK.

K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES.CONTRACTOR TO ASSUME 10% REPLACEMENT.

L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES ASPER MASTER PAINTERS INSTITUTE (MPI) PAINTINGSTANDARD. COORDINATE WITH CLIENT REPRESENTATIVEFOR APPROVED COLOUR SCHEME.

M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPIPAINTING STANDARD. COORDINATE WITH DEPARTMENTALREPRESENTATIVE FOR APPROVED COLOUR SCHEME.

16

17

A3 1:5

WALL MOUNTED PROJECTION SCREEN MOUNTING DETAIL9

18

19

20

21

22

23

24

25

ON

A

IO A OIA

ION

26

Page 5: ACOUSTIC AND FLOORING UPGRADES TO THE ARTS … fileid no. from to nominal dimensions door type mat finish frr frame type mat frame frr system stc hdwr group notes d1 vestibule corridor

W2

905

A48A4

4

27

905

A49

W1

±1535 WINDOW WIDTH

A45

860 R

.O.

1312

1755 R.O.

FIXED

A47

14

27

24

89

140

810 W

INDO

W H

EIGH

T

140

89

22

D7

W2W1SOUNDBOOTH A4

2A43

A45

A44

419STUDIO

418THEATRE

1

2

1

A48

4

A47

12

13

14

14

9

23

26

W1

SOUNDBOOTH

860 R

.O.

810 W

INDO

W H

EIGH

T

418THEATRE

419 STUDIO

316

316

1220

115

SOUND BOOTH

150

SOUND BOOTH

419 STUDIO

152

1070

89

163

OTTAWA, ONTARIO DRAWING / DESSIN

BUSINESS ENTITY / NUMÉRO DE L'ENTITÉBUILDING NUMBER / NUMÉRO DU BÂTIMENT

PROJECT NO. / NUMÉRO DE PROJET

SHEET NO. / FEUILLE No.

CONSULTANT / EXPERT-CONSEIL

CE DESSIN CONSTITUE LA PROPRIÉTÉ DE LAVILLE D'OTTAWA ET TOUT DROIT D'AUTEUR ESTRÉSERVÉ. LES DIMENSIONS UTILISÉES LE SONTÀ DES FINS D'ESTIMATION SEULEMENT. ILINCOMBE À CHAQUE ENTREPRENEUR,SOUS-CONTRACTANT OU CONSULTANT DEVÉRIFIER TOUTES LES DIMENSIONS ET LESCONDITIONS SUR LE CHANTIER. VEUILLEZINFORMER LE PROPRIÉTAIRE DE TOUTEERREUR OU OMISSION AVANT D'ENTAMER LESTRAVAUX. NE DRESSEZ PAS LES PLANS ÀL'ÉCHELLE.

CONSULTANT / EXPERT-CONSEIL CONSULTANT / EXPERT-CONSEIL

PROJECT / LOCATION / PROJET / ENDROIT

ARCHITECT / ARCHITECTE

THIS DRAWING IS THE PROPERTY OF THE CITYOF OTTAWA AND ALL COPYRIGHT ISRESERVED.DIMENSIONS ON DRAWING ARE FORESTIMATING PURPOSES ONLY. IT IS THERESPONSIBILITY OF EACH CONTRACTOR ANDSUB-CONTRACTOR OR CONSULTANT TO CHECKAND VERIFY ALL DIMENSIONS AND CONDITIONSON SITE. NOTIFY OWNER OF ANY ERRORS OROMISSIONS PRIOR TO COMMENCING THEWORK. DO NOT SCALE THE DRAWINGS.

(Y/M/D)(A/M/J)MILESTONE / FAIT SAILLANT DATE:

FOR / POUR

1A1.1

SHEET NUMBER

DETAIL NUMBER

DRAWING TITLESCALE:

NUMBER/NUMÉRO

INITIALSINITIALES

PLANNING AND INFRASTRUCTURE PORTFOLIOINFRASTRUCTURE SERVICES DEPARTMENT

DESIGN AND CONSTRUCTION - BUILDINGS & PARKS BRANCH________________________________________________________________

PORTEFEUILLE DE L'URBANISME ET DE L'INFRASTRUCTUREDÉPARTEMENT DES SERVICES D'INFRASTRUCTURE

DIRECTION DE CONCEPTION ET DE CONSTRUCTION - IMMEUBLES ET DES PARCS

Fax.: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected].: 613-567-9462

Robertson Martin

Phone.: 613-567-1361

Email: [email protected]

Architects

216 Pretoria AvenueOttawa, ON, K1S 1X2

Robertson Martin

Email: [email protected]

TWSH

TWSH

TWSH

2014/04/15

2014/03/31

6

5

4

3

2

1

PARKS, RECREATION & CULTURAL SERVICES

DESIGN & CONSTRUCTION - BUILDINGSCULTURAL & HERITAGE SERVICES

TWSH

ISSUED FOR PERMIT

ISSUED FOR 95% CLIENT REVIEW

2014/03/11ISSUED FOR 60% CLIENT REVIEW

TWSH

AS INDICATEDJLG

CR009876

BE1029 BU1000 A4

INTERIOR ELEVATIONS & DETAILSPLAN ENLARGEMENTSOUND BOOTH

2 DALY AVENUE

SECOND FLOORARTS COURTCITY OF OTTAWA

A4 1:20

SOUND BOOTH PLAN ENLARGEMENT1

EXISTING SOUND BOOTH EQUIPMENT AND CABLING TO BEREMOVED BY CLIENT PRIOR TO CONSTRUCTION.

CONTROL BOOTH TABLE TO REMAIN. PROTECT DURINGCONSTRUCTION.

38 mm ABS CLEANOUT PLUG AND FITTING. PAINT FINISH.

CROSS TALK SILENCER WALL VENT. REFER TO DETAIL 8 / A4.

CABLE PASS-THROUGHS, REFER TO SECTION DETAIL 7/A4.

PROVIDE PRE-FINISHED METAL GRILLES FOR CROSS TALKSILENCER OPENING.

BEAD OF ACOUSTICAL SEALANT.

CONTINUOUS NEOPRENE GASKET.

FIBERGLASS CASEMENT WINDOW WITH LAMINATED GLASS.

19 mm PLYWOOD PAINTED BLACK ALL SIDES.

FIBERGLASS HORIZONTAL SLIDER WINDOW.

OPERABLE WINDOW.

FIXED WINDOW.

CABLE PASS-THROUGHS, REFER TO SECTION DETAIL 7/A4.

ROLLED ACOUSTICAL FOAM PLUG 10mm X 150mm X 280mmSHOWN FOR INTENT ONLY.

EXAMPLE OF CONTROL CABLE THROUGH ROLLEDACOUSTICAL FOAM PLUG.

INSTALL NEW DUCT SUPPORT FRAMING AS REQUIRED.

EXISTING GYPSUM WOOD STUD WALL.

38 mm (1-1/2") Ø ABS PIPE.

19 mm GIS PLYWOOD PAINT FINISHED.

CUT & PATCH EXISTING GYPSUM AS REQUIRED TO INSTALLCROSS TALK SILENCER.

SOLID WOOD BLOCKING.

±400 mm TO ALIGN WITH EXISTING WALL FRAMING SPACING.

TYPICAL - FILL VOIDS IN FRAMING WITH ACOUSTIC BATTINSULATION.

BEAD OF SEALANT.

CROSS TALK SILENCER CEILING VENT. REFER TO SECTIONDETAIL 9 / A4.

19 mm GIS PLYWOOD WITH 3 mm HARD WOOD EDGE PAINTEDBLACK ALL SIDES.

1

NOTES

3 THEATRE WINDOW ELEVATION1:10A4

2 STUDIO WINDOW ELEVATION1:20A4

4 STUDIO WINDOW SECTION1:5A4

5 THEATRE WINDOW SECTION1:5A4

2

3

4

5

6

7

8

9

10

11

8 SECTION DETAIL- CROSS TALK SILENCER1:5A4

6 SECTION DETAIL - CASEMENT WINDOW SILL1:2A4

7 SECTION DETAIL - CABLE PASS-THROUGH1:2A4

12

13

14

15

16

17

18

19

20

GENERAL NOTESA. CITY OF OTTAWA RESPONSIBLE TO OBTAIN BUILDING

PERMIT, CONTRACTOR IS RESPONSIBLE FOR ALL OTHERREQUIREMENTS FOR AUTHORITIES HAVING JURISDICTION,INCLUDING BUT NOT LIMITED TO, ESA CERTIFICATE.

B. ALL DRAWINGS TO BE READ IN CONJUNCTION WITH ALLOTHER DRAWINGS & SPECIFICATIONS.

C. DO NOT SCALE DRAWINGS. CONTRACTOR TO VERIFY ALLDIMENSIONS ON SITE.

D. CONTRACTOR TO IMMEDIATELY NOTIFY CLIENTREPRESENTATIVE IN WRITING OF ANY DISCREPANCIES OFDIMENSIONS, MATERIALS, AND/OR CONDITIONS.

E. UNLESS OTHERWISE INDICATED AS EXISTING, ALLMATERIALS ARE NEW AND TO BE SUPPLIED & INSTALLED ASPART OF THIS CONTRACT.

F. CITY OF OTTAWA TO REMOVE ALL FURNITURE AND RETURNTO THE DESIRED END PLACE BUT WILL NOT BERESPONSIBLE FOR INSTALLATIONS.

G. ALL ELECTRICAL WORK TO BE CARRIED OUT BY ACERTIFIED ELECTRICIAN.

H. PROTECT ALL ELECTRICAL CONTROLS AND FIXTURES TOREMAIN.

I. PROTECT FLOOR FINISH TO REMAIN FROM DAMAGE WHENPROCEEDING WITH PROJECT WORK.

J. REPAIR AND REFINISH DAMAGE CAUSED BY PROJECTWORK.

K. REPLACE EXISTING DAMAGED SUSPENDED CEILING TILES.CONTRACTOR TO ASSUME 10% REPLACEMENT.

L. SURFACE PREP & PAINT FINISH ALL GYPSUM SURFACES ASPER MASTER PAINTERS INSTITUTE (MPI) PAINTINGSTANDARD. COORDINATE WITH CLIENT REPRESENTATIVEFOR APPROVED COLOUR SCHEME.

M. SURFACE PREP & PAINT FINISH ALL DOORS AS PER MPIPAINTING STANDARD. COORDINATE WITH DEPARTMENTALREPRESENTATIVE FOR APPROVED COLOUR SCHEME.

21

22

23

24

25

ON

A

IO A OIA

ION

9 SECTION DETAIL- CROSS TALK SILENCER1:5A4

26

27