Fast
Handheld
Accurate
ichroma™ M is the small, battery operated true mobile
diagnostic device with new sensitive technology,
comparable to accuracy of auto-analyzer. With
respiratory tests panel and high sensitivity, ichroma™ M
will brings the test laboratory on your palm.
ichroma™ M Flu A+B
Room TemperatureNo need for refrigerator
SimpleMix, drop and insert.
Safety of DataAutomatic backup up to 100 results and LIS connectivity
Versatile All respiratory test (Flu, RSV*, Strep A*, and bacterial pneumonia*)
Test Procedure
Multi Mode
Flu A:Positive +
Flu B:Negative -
Single Mode
Specifications
Influenza A+B
Strep A*
PSV*
Pneumonia*
*available late 2017
Test itemsItem
Dimensions (LxWxH,mm)
Weight
Power
Battery life
Data output
Operation Temperature
Humidity
Memory
202.0 x 83.0 x 45
350 g
Battery (4 x AA)
100 tests
LCD / USB mini B
15 ~ 30°C(59~80℉)
20 - 80 %
100 tests
ichroma™ M Influenza A+B Accuracy
Flu A
vs CultureCulture
Total+ -
ichromaTM M ichromaTM M
ichromaTM M ichromaTM M
+ 53 4 57
- 3 119 122
Total 56 123 179
Sensitivity: 53/56 = 94.6%
Specificity: 119/123 = 96.7%
Total agreement: 172/179 = 96.1%
Flu A
vs PCRPCR
Total+ -
+ 74 0 74
- 1 125 126
Total 75 125 200
Sensitivity: 74/75 = 98.7%
Specificity: 125/125 = 100%
Total agreement: 199/200 = 99.5%
Flu B
vs CultureCulture
Total+ -
+ 53 3 56
- 3 120 123
Total 56 123 179
Sensitivity: 53/56 = 94.6%
Specificity: 120/123 = 97.6%
Total agreement: 173/179 = 96.6%
Flu B
vs PCRPCR
Total+ -
+ 72 0 72
- 3 125 128
Total 75 125 200
Sensitivity: 72/75 = 96.0%
Specificity: 125/125 = 100%
Total agreement: 197/200 = 98.5%
Distributed by 43, Geodudanji 1-gil, Dongnae-myeon, Chuncheon-si, Gang-won-do, Korea Tel: +82-33-243-1400 Fax: +82-33-243-9373
Boditech Med Inc.
For more information, please visit:
www.boditech.co.krFor sales related matters, please write to us at
Rev 02_ichroma M