Home Bladder Diaphragm Accessories Bladder Maintenance STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORS CLAMPS FILTRATION Stauff Accumulators stauff.com Diaphragm Maintenance Introduction Bladder accumulators provide a means of regulating the performance of a hydraulic system. They are suitable for storing energy under pressure, absorbing hydraulic shock, dampening pump pulsation and flow fluctuations. Bladder accumulators provide excellent gas and fluid separation ensuring dependable performance, maximum efficiency, and long service life. Why use a Bladder Accumulator? • Improves your systems efficiency • Supplements your pump flow • Supplies extra power in an emergency • Compensates for any system leakage • Absorbs hydraulic shocks • Accepted world wide • High/Low temperature tolerance • Extremely safe (can not disassemble under pressure) • Quick response • Wide range of compounds for a variety of fluids Accumulator Function The design of the Stauff bladder accumulator makes use of the difference in the compressibility between a gas (nitrogen) and a liquid (hydraulic fluids). The bladder contained in the shell is pre-charged with nitrogen gas to a pressure determined by the work to be done. After pre-charging, the bladder occupies the entire volume of the shell, from there the work can be split into three steps. Step 1. When the hydraulic fluid enters the accumulator, the nitrogen con- tained in the bladder is compressed and its pressure is increased. Step 2. The compression of the bladder stops when the pressure of the fluid and nitrogen are equal (balanced). During this step the bladder is not subject to any abnormal mechanical stress. Step 3. On demand, as system pressure falls, the accumulator’s stored fluid is returned to the system under pressure applied by the compressed nitrogen. On completion of the hydraulic system functions, the accumulator reverts to step 1.

ACCUMULATORS Home Stauff Accumulatorskrwest.com/downloads/stauff/H_Accumulators.pdf · Accumulator Accesories Accumulator Brackets AMP, AMP/D 16 Base Brackets BB 17 Rubber Rings RR

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Accumulators

    stauff .com

    Diaphragm Maintenance

    Introduction Bladder accumulators provide a means of regulating the performance of a hydraulic system.

    They are suitable for storing energy under pressure, absorbing hydraulic shock, dampening pump pulsation and flow fluctuations.

    Bladder accumulators provide excellent gas and fluid separation ensuring dependable performance, maximum efficiency, and long service life. Why use a Bladder Accumulator? •Improvesyoursystemsefficiency •Supplementsyourpumpflow •Suppliesextrapowerinanemergency •Compensatesforanysystemleakage •Absorbshydraulicshocks •Acceptedworldwide •High/Lowtemperaturetolerance •Extremelysafe(cannotdisassembleunderpressure) •Quickresponse •Widerangeofcompoundsforavarietyoffluids

    Accumulator Function The design of the Stauff bladder accumulator makes use of the differenceinthecompressibilitybetweenagas(nitrogen)andaliquid(hydraulicfluids).Thebladdercontainedintheshellispre-chargedwith nitrogen gas to a pressure determined by the work to be done.

    Afterpre-charging,thebladderoccupiestheentirevolumeoftheshell, from there the work can be split into three steps.

    Step 1.Whenthehydraulicfluidenterstheaccumulator,thenitrogencon-tained in the bladder is compressed and its pressure is increased.

    Step 2.The compression of the bladder stops when the pressure of the fluid andnitrogenareequal(balanced).Duringthisstepthebladderisnotsubject to any abnormal mechanical stress.

    Step 3.On demand, as system pressure falls, the accumulator’s stored fluid is returned to the system under pressure applied by the compressed nitrogen. On completion of the hydraulic system functions, the accumulator reverts to step 1.

    http://www.stauff.comhttp://www.stauff.com

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Bladder Accumulators

    stauff .com

    Diaphragm Maintenance

    Stauff STA-S Series

    Design Features & Benefits

    3000 PSI / 207 Bar Bottom Repairable

    3000 PSI / 207 Bar Bottom Repairable High Flow

    3000 PSI / 207 Bar Top Repairable

    5000 PSI / 345 Bar Bottom Repairable High Flow

    Bladder Accumulator Order Code Type STBA

    Technical Data & Dimensions Replacement Bladders

    3000 PSI / 5000 PSI - 207 / 345 Bar

    Replacement Bladders Order Code Type STB

    Charge Kits, Repair Kits, Port Adaptors & Safety Valves

    http://www.stauff.comhttp://www.stauff.com

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Diaphragm Accumulators

    stauff .com

    Diaphragm Maintenance

    STDA Series

    Dimensions

    Order Code

    Charge Kits & Gas Valve Conversion Kits

    http://www.stauff.comhttp://www.stauff.com

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Accumulator Accessories

    stauff .com

    Diaphragm Maintenance

    Accumulator Brackets Type AMP & AMP/D

    Base Brackets & Rubber Rings Type BB & RR Series

    Mounting Brackets Compatibility Information

    for Bladder Accumulators

    Dimensions & Order Code Round Steel U-Bolt Clamps

    Type RBD

    http://www.stauff.comhttp://www.stauff.com

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Bladder Accumulator Operating & Maintenance

    stauff .com

    Diaphragm Maintenance

    Instructions

    3000 PSI AccumulatorsParts Breakdown

    3000 PSI Top Repairable, 1 Qt.

    3000 PSI Bottom Repairable, 1 to 15 Gallon, Standard

    and High Flow

    3000 PSI Bottom Repairable, 2.5 to 15 Gallon

    Pre-Charging

    Checking Pre-Charge Pressure

    5000 PSI AccumulatorsBottom Repairable, 2.5 to 15 Gallon

    Parts Breakdown

    Pre-Charging

    Checking Pre-Charge Pressure

    Bladder AccumulatorsDisassembling Procedures

    Disassembling Instructions

    Trouble Shooting Guide

    Assembly Procedures

    Assembly Instructions

    Sizing Data & Application

    Discharge Coefficient

    Instructions for Selection of Discharge Coefficient “n”

    Sizing Problem #1

    Supplementing Pump Flow

    Sizing Problem #2

    Increasing Actuation Speed in

    an Existing Hydraulic System

    Sizing Problem #3

    Shock Suppression

    http://www.stauff.comhttp://www.stauff.com

  • Home

    Bladder

    Diaphragm

    Accessories

    Bladder Maintenance

    STAUFF Corperation Call us today 201.444.7800 or visit www.stauff.com

    TEST DIAGTRONICS ACCESSORIES VALVES FLANGES ACCUMULATORSCLAMPS FILTRATION

    Stauff Diaphragm Accumulator Operating & Maintenance

    stauff .com

    Diaphragm Maintenance

    GuidelinesforSelection,InstallationandOperation

    Operating&MaintenanceInstructions

    Pre-Charging Diaphragm Accumulators

    USStyleCoredGasValve

    MetricM28x1.5GasValve

    Checking Pre-Charge Pressure

    MetricM28x1.5GasValve

    USStyleCoredGasValve

    http://www.stauff.comhttp://www.stauff.com

  • 1 www.stauff.com

    Contents

    Accumulators and Accessories

    Stauff Bladder Accumulators STBA Design Features 2 Material Options 2 3000 PSI / 201 Bar Bottom Repairable Dimensions 4 3000 PSI / 201 Bar Bottom Repairable High Flow Dimensions 5 3000 PSI / 201 Bar Top Repairable Dimensions 6 3000 PSI / 345 Bar Bottom Repairable Dimensions 7 Ordering Codes 8 Availability Chart 8

    Replacement Bladders STB 9 Technical Data 9 Odering Codes 10

    Replacement Gas Valves - STA-AS-GV 9Charging Kits 3000 PSI Bottom and Top Repairable STBA-CK-B/T-P3 11 5000 PSI Bottom Repairable STBA-CK-B-P5 11Repair Kit STA-R-1 11

    SAE to Spit Flange Connector Code 61 3000 PSI 302 11 Code 62 6000 PSI 602 11Spilt Flanges Code 61 3000 PSI DB 11 Code 62 6000 PSI DB 11

    Diaphragm Accumulators STDA 12 Technical Data 12 Dimensions 13 Ordering Codes 14US Style Gas Valve Conversion Kit STDA-X-K 15Charging Kits Metric Gas Valve STDA-CK-M-P3 15 US Style Gas Valve STBA-CK-B-P3 15

    Accumulator Accesories Accumulator Brackets AMP, AMP/D 16 Base Brackets BB 17 Rubber Rings RR 17 U Bolts RBD 19

    Bladder Accumulator Operating and Maintenance Instructions 20 Parts Break Down 3000 PSI Bottom Repairable, 1 Qt 21 3000 PSI Bottom Repairable, 1 tp 15 Gallon 22 3000 PSI Top Repairable, 2.5 t0 15 Gallon 23 5000 PSI Bottom Repairable 2.5 to 15 Gallon 26 Pre Charging and Pre Charge Checking 3000 PSI 24 5000 PSI 27 Dissasembly Procedures 29 Trouble Shooting 31 Assembly Procedures 33 Sizing 35

    Diaphragm Accumulator Operating and Maintenance Instructions 40 Guidelines, Installation, and Operation 40 Pre-Charging US Style Gas Valve 42 Metric Gas Valve 43 Pre-Charge Checking US Style Gas Valve 44 Metric Gas Valve 45

    www.stauff.com

  • www.stauff.com 1

    Bladder AccumulatorsGeneral Information

    Introduction

    Bladder accumulators provide a means of regulating the performance of a hydraulic system.

    They are suitable for storing energy under pressure, absorbing hydraulic shock, dampening pump pulsation and flow fluctuations.

    Bladder accumulators provide excellent gas and fluid separation ensuring dependable performance, maximum efficiency, and long service life.

    Why use a Bladder Accumulator?

    Improves your systems efficiency Supplements your pump flow Supplies extra power in an emergency Compensates for any system leakage Absorbs hydraulic shocks Accepted world wide High/ Low temperature tolerance Extremely safe (can not disassemble under pressure) Quick response Wide range of compounds for a variety of fluids

    Accumulator Function

    The design of the Stauff bladder accumulator makes use of the difference in the compressibility between a gas (nitrogen) and a liquid (hydraulic fluids). The bladder contained in the shell is pre-charged with nitrogen gas to a pressure determined by the work to be done.

    After pre-charging, the bladder occupies the entire volume of the shell, from there the work can be split into three steps.

    Step 1. When the hydraulic fluid enters the accumulator, the nitrogen contained in the bladder is compressed and its pressure is increased.

    Step 2. The compression of the bladder stops when the pressure of the fluid and nitrogen are equal (balanced). During this step the bladder is not subject to any abnormal mechanical stress.

    Step 3. On demand, as system pressure falls, the accumulator’s stored fluid is returned to the system under pressure applied by the compressed nitrogen. On completion of the hydraulic system functions, the accumulator reverts to step 1.

    Bladder Accumulators

  • 2 www.stauff.com

    Bladder Accumulators Specifications

    Stauff STA-S SeriesMaterial Options & Features

    Main Components Standard Material Material Options Features

    Shell

    Chrome-MollybdenumAlloy Steel (SA-372)

    All sizes comply with ASME materials specifications

    Black Epoxy coating

    Consult factory for details

    Meets 4:1 safety requirements

    Seamless shell

    1 Gallon and larger supplied with ASME Certification

    Bladder

    Nitrile (N)(Buna N)

    Temp Rating

    EPDM (D)

    Consult factory for other options

    Temp Rating

    With molded steel valve stems

    Wide range of materials and temperature ranges

    ˚C ˚F ˚C ˚F

    -23 ... +104 -10 ... +220-48 ... 166 -55 ... +330

    Low Temp Nitrile (L) -51 ... +93 -60 ... +200

    FPM (F)(Viton)

    -17 ... +176 0 ... +350

    Oil Port AssemblyCarbon Steel ANSI 4130 Material Specification

    Black Phosphate coatingConsult factory for other options

    Proven design and reliability

    Many port options available

    High flow option

    Size (Gallon)Maximum Recomended FlowGPM LPM

    1 Qt 40 150

    1 150 565

    2.5 - 15 220 830

    2.5 - 15High Flow

    396 1495

    Bladder Accumulator Features

    Meets A.S.M.E. specifications 4:1 design factor at normal operating pressures. Also available with foreign certificates (upon request) Interchangeable with most competitor’s units. All standard accumulators available from stock.

  • www.stauff.com 3

    Bladder AccumulatorsSpecifications

    Design Features & Benefits

    1. ShellSTAUFF accumulator shells are made from Chrome-Molybdenum Alloy Steel (SA372) with forged ends for maximum strength providing a minimum 4 to 1 design factor at normal operating pressures. All sizes comply with ASME material specifications, 1 gallon & larger are supplied with ASME Certifications upon request.

    2. BladderSTAUFF bladders are manufactured from the most advanced elastomers which are capable of meeting a wide range of systems requirements. Bladders are offered in a variety of compounds to meet a wide range of fluids and operating temperatures. STAUFF can supply Buna, Low Temperature Buna and Viton bladders from stock.

    3. Bladder StemsAll bladder accumulators, sizes 1 gallon and larger, are fitted as standard with a two-piece bladder stem and a replaceable gas valve cartridge for ease of serviceability.

    4. Port AssembliesStandard oil service ports are made from high-strength alloy steel for maximum durability.

    5. Fluid PortsSAE straight thread (standard), NPT and Split Flange Adaptors are available (See page 11). A Bleed Port (plugged) is included as standard on all accumulator sizes 1 gallon and larger.

    6. Gas ValveAll accumulators are fitted with a gas valve for ease of gas pre-charging. One-gallon and larger units are equipped with a cored gas valve cartridge (ISO-4570-8V1) for ease of maintenance. 5000 PSI units are equipped with a high pressure cored gas valve cartridge (Mil. Spec. M6164-2). For safety, the gas valve vents if unscrewed.

    7. Top RepairableThe top repairable design permits easy maintenance of the Accumulator Bladder without removing the accumulator from service, thus minimizing costly downtime.

    1

    6 7

    3

    2

    45

  • 4 www.stauff.com

    Bladder Accumulators Capacities & Dimensions

    3000 PSI / 207 Bar Bottom RepairableDimensions

    Nominal Capacity(Gallons/Liter)

    Gas Volume(in3/cm3)

    Maximum Working(PSI/Bar)

    Dimensions (mm/in) Net Weight(Kg/Lb)

    A B CD

    EF

    SAE NPT SAE

    *1 Qt. 67.1 3000 114 291 50 SAE-12(1-1/16" - 12) 3/4"

    42 N/A 4.5

    1.0 1190 207 . 4.49 11.46 1.97 1.65 10

    1.0 234.6 3000 168 420 87 SAE-20 (1-5/8" - 12) 1-1/4"

    60 SAE-6 (9/16"-18)

    15

    4.0 3845 207 6.8 16.55 3.42 2.36 34

    2.5 587 3000 229 850 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 9/16"-18)

    36

    10 9620 207 9.02 33.46 3.54 3.00 79

    5 1132 3000 229 1245 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    54

    20 18548 207 9.02 49.02 3.54 3.00 119

    10 2075 3000 229 1390 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    100

    40 34000 207 9.02 54.72 3.54 3.00 220

    11 2514 3000 229 1530 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    109

    44 41210 207 9.02 60.24 3.54 3.00 240

    15 3234 3000 229 1975 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    138

    60 53000 207 9.02 77.76 3.54 3.00 304

    * In accordance with ASME VII calculations only

    A

    D

    E

    F

    B

    CInstallation Note: Leave approximately 8" (200mm) for installation of gas charging valve.

    ø 2.81 (71.5)

    9/16"-12(SAE-6)

    4.72

    (120

    .0)

    O-RINGOptional Split Flange Adapter Port. For use with 2" SAE code 61 split flange (not included).

  • www.stauff.com 5

    A

    D

    E

    F

    B

    C

    Bladder AccumulatorsCapacities & Dimensions

    3000 PSI / 207 Bar Bottom Repairable High FlowDimensions

    Nominal Capacity(Gallons/Liter)

    Gas Volume(in3/cm3)

    Maximum Working(PSI/Bar)

    Dimensions (mm/in) Net Weight(Kg/Lb)

    A B CD

    EF

    NPT SAE

    2.5 587 3000 229 608 1553-1/2" Male or 3" Female

    108 SAE-6 (9/16"-18)

    37

    10 9620 207 9.02 23.94 6.10 4.25 82

    5 1132 3000 229 913 1553-1/2" Male or 3" Female

    108 SAE-6 (9/16"-18)

    55

    20 18548 207 9.02 35.95 6.10 4.25 121

    10 2075 3000 229 1438 1553-1/2" Male or 3" Female

    108 SAE-6 (9/16"-18)

    101

    40 34000 207 9.02 56.61 6.10 4.25 223

    11 2514 3000 229 1588 1553-1/2" Male or 3" Female

    108 SAE-6 (9/16"-18)

    110

    44 41210 207 9.02 62.52 6.10 4.25 243

    15 3234 3000 229 2043 1553-1/2" Male or 3" Female

    108 SAE-6 (9/16"-18)

    139

    60 53000 207 9.02 80.43 6.10 4.25 306

    Installation Note: Leave approximately 8" (200mm) for installation of gas charging valve.

    E

    9/16"-12(SAE-6)

    [1.57]40.0

    [0.16] 4.0

    5.71

    [145

    .0]

    [8.66] 220.0 SQUARE

    [6.69] 170.0 SQUARE

    4x ø[1.02] 26.0 THRU

    ø[3.74] 95.0ø[3.07] 78.0

    O-RING

    Optional Split Flange Adapter Port. For use with 2" SAE code 62 split flange (not included).

  • 6 www.stauff.com

    Bladder Accumulators Capacities & Dimensions

    3000 PSI / 207 Bar Top RepairableDimensions

    Nominal Capacity(Gallons/Liter)

    Gas Volume(in3/cm3)

    Maximum Working(PSI/Bar)

    Dimensions (mm/in) Net Weight(Kg/Lb)

    A B CD

    EF

    SAE NPT SAE

    2.5 587 3000 229 541 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 9/16"-18)

    36

    10 9620 207 9.02 21.30 3.54 3.00 79

    5 1132 3000 229 841 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    54

    20 18548 207 9.02 33.11 3.54 3.00 119

    10 2075 3000 229 1521 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    100

    40 34000 207 9.02 59.88 3.54 3.00 220

    11 2514 3000 229 1521 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    109

    44 41210 207 9.02 59.88 3.54 3.00 240

    15 3234 3000 229 1976 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    138

    60 53000 207 9.02 77.80 3.54 3.00 304

    Consult factory for other sizes

    A

    D EF

    B

    C

    Installation Note: Leave approximately 8" (200mm) for installation of gas charging valve.

    ø 2.81 (71.5)

    9/16"-12(SAE-6)

    4.72

    (120

    .0)

    O-RINGOptional Split Flange Adapter Port. For use with 2" SAE code 61 split flange (not included).

  • www.stauff.com 7

    Bladder AccumulatorsCapacities & Dimensions

    5000 PSI / 345 Bar Bottom Repairable Dimensions

    Nominal Capacity(Gallons/Liter)

    Gas Volume(in3/cm3)

    Maximum Working(PSI/Bar)

    Dimensions (mm/in) Net Weight(Kg/Lb)

    A B CD

    EF

    SAE NPT SAE

    2.5 587 5000 245 560 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 9/16"-18)

    57

    10 9620 345 9.65 22.05 3.54 3.00 126

    5 1132 5000 245 870 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    91

    20 18548 345 9.65 34.25 3.54 3.00 200

    10 2075 5000 245 1395 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    159

    40 34000 345 9.65 54.92 3.54 3.00 350

    15 3234 5000 245 1990 90 SAE-24 (1-7/8" - 12) 2"

    76 SAE-6 (9/16"-18)

    227

    60 53000 345 9.65 78.35 3.54 3.00 500

    Consult factory for other sizes

    A

    D

    F

    C

    B

    Installation Note: Leave approximately 8" (200mm) for installation of gas charging valve.

    Eø 3.13 (79.5)

    9/16"-12(SAE-6)

    4.58

    (115

    .0)

    O-RINGOptional Split Flange Adapter Port. For use with 2" SAE code 62 split flange (not included).

    E

  • 8 www.stauff.com

    l m n

    STBA H - 010 - 3000 S B / N U C 7 C / N C / C

    Availability Chart

    Fluid Port Connections

    l Fluid Port Connection SAE Threaded U NPT N 1-1/2" SAE Code 61 Split Flanged (3000 PSI) S 1-1/2" SAE Code 62 Split Flanged (6000 PSI) F Four Bolt Flange (High Flow) H

    m Material Carbon Steel (STD) C Please consult STAUFF for availability of other materials

    n Material or Coating of the Shell Carbon Steel, Black Epoxy Coated (STD) C Please consult STAUFF for availability of other materials

    Bladder Accumulator Type STBAOrder Codes

    f Bottom or Top Repairable Bottom Repairable B Top Repairable T

    g Bladder Material Nitrile (Buna N) N Low Temp Nitrile L EPDM D FPM F Please consult STAUFF for availability of other materials

    h Gas Valve Connection Cored gas valve for 3000 PSI Accumulators U Military Style Gas Valve for 5000 PSI Accumulators M i Gas Valve Material Carbon Steel (Standard) C Consult STAUFF for availability of other materials

    j Bladder Stem Size 5/8"-18 UNF (For use with 1 Quart 3000 PSI) 5 7/8"-14 UNF (For use with 1 Gal to 15 Gal 3000 PSI) 7 2"-12 UNF (For use with 5000 PSI) 2

    k Bladder Stem Material Carbon Steel (Standard) C Please consult STAUFF for availability of other materials

    a Model Code Bladder Accumulator STBA

    b Accumulator Type Standard Omit Hi Flow H

    c Size

    d Pressure Rating According to Standard 3000 PSI / 207 Bar 3000 5000 PSI / 345 Bar 5000

    e Design Approval ASME S This catalog relates to ASME certified accumulators. ASME certifications are available upon request. Please request at the time of ordering. CE PED (Europe), AS1210 (Australia) and GB/T 20663 (China) certified accumulators are also available. Please consult STAUFF for details.

    Volume ( Gal) Size1 Quart 0011 Gallon 0042.5 Gallon 0105 Gallon 02010 Gallon 03511 Gallon 04015 Gallon 055

    Size Code Gallons (Ltrs) Volume 3000 PSI Bottom Repairable3000 PSI Bottom Repairable High Flow

    3000 PSI Top Repairable 5000 PSI Bottom Repairable

    001 1 Quart (1 Litre) Yes N/A N/A N/A

    004 1 Gallon (4 Litre) Yes N/A N/A N/A

    010 2.5 Gallon (10 Litre) Yes Yes Yes Yes

    020 5 Gallon (20 Litre) Yes Yes Yes Yes

    035 10 Gallon (35 Litre) Yes Yes N/A Yes

    040 11 Gallon (40 Litre) Yes Yes Yes N/A

    055 15 Gallon (55 Litre) Yes Yes Yes Yes

    Size Code 1 Qrt 1 Gal 2.5 to 15 GalHigh Flow2.5 to 15 Gal

    Threaded SAE U SAE 12 (1-1/16"-12) SAE 20 (1-5/8"-12) SAE 24 (1-7/8"-12) N/A

    NPTN 3/4 1-1/4 2" 3.5" Male

    N1 N/A N/A N/A 3" Female

    Split Flanged Code 61 - 3000 PSI S N/A N/A 1-1/2" N/A

    Split Flanged Code 62 - 6000 PSI F N/A N/A 1-1/2" N/A

    Four Bolt Flange H N/A N/A 1-1/2" See page 5

    Bladder Accumulators Order Code

  • www.stauff.com 9

    Replacement BladdersTechnical Data & Dimensions

    3000 PSI / 5000 PSI - 207 / 345 Bar

    1 Qt. Stem Detail3000 PSI

    1 to 15 GallonStem Detail 3000 PSI

    2.5 to 15 GallonStem Detail 5000 PSI

    Stauff offers a wide range of bladder materials to suit most applications.Stauff bladder kits includeQty (1) Bladder with molded valve stemQty (1) Gas valve and O-RingQty (1) Poppet valve O-RingQty (1) Back up seal O-RingSee the technical appendix for more information

    Temperature Rating

    ˚C ˚F

    Nitrile (N)(Buna N)Low Temp Nitrile (L)FPM (F)Viton

    -23 ... +104

    -51 ... +93

    -17 ... +176

    -10 ... +220

    -60 ... +200

    0 ... +350

    EPDM (D)Consult Factory for other options

    -48 .. 166 -55 .. +330

    Accumulator Nominal CapacityGallons/Liter

    Dimensions (mm/in)

    H DStem Thread Gas Valve

    3000 PSI 5000 PSI 3000 PSI 5000 PSI

    1 Qt. 146 +/- 12.7 95.35/8"-18 UNF-2A N/A

    Valve CoreSTDA-AS-GV-1Qt-P3

    N/A1.0 5.75 +/- 0.5 3.75

    1.0 203 +/- 12.7 139.77/8"-14 UNF-2A N/A

    Valve CartridgeSTA-AS-GV-1-15-P3

    N/A4.0 8.0 +/- 0.5 5.50

    2.5 292 +/- 12.7 2037/8"-14 UNF-2A 2"-12 UN-2A

    Valve CartridgeSTA-AS-GV-1-15-P3

    Valve CartridgeSTA-AS-GV-1-15-P510 11.50 +/- 0.5 8.0

    5 584 +/- 25.4 2037/8"-14 UNF-2A 2"-12 UN-2A

    Valve CartridgeSTA-AS-GV-1-15-P3

    Valve CartridgeSTA-AS-GV-1-15-P520 23.0 +/- 1.0 8.0

    10 1105 +/- 25.4 2037/8"-18 UNF-2A 2"-12 UN-2A

    Valve CartridgeSTA-AS-GV-1-15-P3

    Valve CartridgeSTA-AS-GV-1-15-P535 43.5 +/- 1.0 8.0

    11 1257 +/- 25.4 2037/8"-14 UNF-2A 2"-12 UN-2A

    Valve CartridgeSTA-AS-GV-1-15-P3

    Valve CartridgeSTA-AS-GV-1-15-P540 49.5 +/- 1.0 8.0

    13 1626 +/- 25.4 2037/8"-18 UNF-2A 2"-12 UN-2A Valve Cartridge

    STA-AS-GV-1-15-P3Valve CartridgeSTA-AS-GV-1-15-P550 64.0 +/- 1.0 8.0

    15 1727 +/- 25.4 2037/8"-14 UNF-2A 2"-12 UN-2A Valve Cartridge

    STA-AS-GV-1-15-P3Valve CartridgeSTA-AS-GV-1-15-P560 68.0 +/- 1.0 8.0

    Stauff accumulators and replacement bladder kits are shipped with industry standard gas valves and protective caps.

    3000 PSI Cored Gas ValveCartridge (ISO-4570-8V1)Stauff Part NumberSTA-AS-GV-1-15-P3

    For 3000 PSI Accumulators, 1 Gallon to 15 Gallon

    5000 PSI Valve CartridgeStauff Part NumberSTA-AS-GV-1-15-P5

    For 5000 PSI Accumulators,2.5 Gallon to 15 Gallon

    H

  • 10 www.stauff.com

    STB - 010 - 3000 / N U C 7 C

    e Gas Valve Connection Cored gas valve for 3000 PSI Accumulators U Military Style Gas Valve for 5000 PSI Accumulators M f Gas Valve Material Carbon Steel (Standard) C Consult STAUFF for availability of other materials

    g Bladder Stem Size 5/8"-18 UNF (For use with 1 Quart 3000 PSI) 5 7/8"-14 UNF (For use with 1 Gal to 15 Gal 3000 PSI) 7 2"-12 UNF (For use with 5000 PSI) 2

    h Bladder Stem Material Carbon Steel (Standard) C Please consult STAUFF for availability of other materials

    Replacement Bladder Type STBOrder Codes

    c Pressure Rating According to Standard 3000 PSI / 207 Bar 3000 5000 PSI / 345 Bar 5000

    d Bladder Material Nitrile (Buna N) N Low Temp Nitrile L EPDM D FPM F Please consult STAUFF for availability of other materials

    a Model Code Bladder Kit STB

    b Size Volume (Gal) Code

    1 Quart 0011 Gallon 0042.5 Gallon 0105 Gallon 02010 Gallon 03511 Gallon 04015 Gallon 055

    Replacement Bladders Order Code Part Numbers

    Stauff Bladder Kits include:Qty (1) Bladder with molded valve stemQty (1) Gas valve and O-RingQty (1) Poppet valve O-RingQty (1) Back up seal O-Ring

    Please see the maintenance instructions on page 20 for details

  • www.stauff.com 11

    Bladder AccumulatorsCharge Kits, Repair Kits, Port Adaptors & Safety Valves

    Charging Kit

    Repair Kit

    Accumulator Safety Valve

    Port Adaptors (SAE to Flange)

    STBA-CK-B/T-P3Charging Kit for Bottom and Top Repairable3000 PSI AccumulatorsIncludes: STBA-PC2157 Charge Valve assembly and test point SPG-063-0250-01-P-B04 Gauge 0 to 3625 PSI (0 to 250 bar) STBA-P3-3048MM-B 3000 PSI Nitrogen bottled adapter and hose assembly, 3048mm (12 in) long

    STBA-50019 Fitting Adaptor, .305-32 UNS (female) to 5/8"-18-2AUNF (Male)

    STBA-10143 Fitting Adaptor, 7/8"-14 UNF (female) to 5/8"-18-2AUNF (Male)

    STBA-VLV-EXT-1 Gas Valve Extension for 3000 PSI Top Repairable Accumulator

    STBA-C-1 Case with foam

    STBA-CK-B-P5Charging Kit for Bottom Repairable5000 PSI AccumulatorsIncludes: STBA-PC2157 Charge Valve assembly and test point SPG-063-0400-01-P-B04 Gauge 0 to 5800 PSI (0 ... 400 bar)

    STBA-P5-3048MM-B 5000 PSI Nitrogen bottled adapter and hose assembly, 3048mm (12 in) long

    STBA-50019 Fitting Adaptor, .305-32 UNS (female) to 5/8"-18-2A UNF (Male)

    STBA-C-1 Case with foam

    Repair Kit Part # STA-R-1Repair kit includes the following parts: Set of pull rods Set of hydraulic valve wrenches Set of gas valve tools Case and foam

    Accumulator Safety Valves Provides manual isolation of the accumulator from the hydraulic circuit

    Integrated relief valve to protect the accumulator from over pressure

    Available with manual or electric dump vavles Consult STAUFF formore information

    SAE to Split Flange Connector

    Part # Description

    302-12-12 #12 SAE to 3/4" Flange

    302-20-20 #20 SAE to 1-1/4" Flange

    302-24-24 #24 SAE to 1-1/2" Flange

    Split Flanges

    Part # Description

    DB-302--AS-U-B#K 3/4" Split Flange

    DB-304--AS-U-B#K 1-1/4" Split Flange

    DB-305--AS-U-B#K 1-1/2" Split Flange

    SAE to Split Flange Connector

    Part # Description

    602-12-12 #12 SAE to 3/4" Flange

    602-20-20 #20 SAE to 1-1/4" Flange

    602-24-24 #24 SAE to 1-1/2" Flange

    Split Flanges

    Part # Description

    DB-602-AS-U-B#K 3/4" Split Flange

    DB-604--AS-U-B#K 1-1/4" Split Flange

    DB-605--AS-U-B#K 1-1/2" Split Flange

    Code #61 (3000 PSI) Code #61 (3000 PSI)

    Code #62 (6000 PSI) Code #62 (6000 PSI)

  • 12 www.stauff.com

    Technical Data

    Electron Beam Welded Construction High Strength Alloy Steel Shell Compact Design Operating Pressure to 3600 PSI (250 Bar) Capacity up to 3.5 Liters Hydrin (ECO) Diaphragm Material (Standard) Operating Temperature Range -40° ... +80°C / (-40° ... +170°F) Low Permeation Coefficient Up to 1:8 Compression Ration (Precharge/Maximum Working) UNF Oil Port Connection (Standard) Conforms to CE97/23 Corrosion Resistant Black Gloss Finish Metric Gas Valve (Standard)

    Options

    Gas Port Precharged Hermetically Sealed (non-rechargeable) US Style Gas Valve

    Oil Port BSP, Metric, Male/Female Metric Combination, ORFS

    Diaphragm Material Nitrile (Buna) Fluroelastomer (Viton) Other materials upon request

    Why use a Diaphragm Accumulator? Compact & Lightweight Design Fast Response Time Cost Effective Supplements Pump Flow Extends System Life Absorbs Shock Contamination Tolerant

    Diaphragm Accumulator Features

    Maximum compression ratio = 1 : 8 (maximum working pressure / pre-charge pressure) Refer to Stauff catalog for individual accumulator compression ratios.

    Compact and light weight Cost effective Non-repairable design Interchange with most competitor’s units All standard accumulators available from stock.

    Maximum Flow Rates

    Diaphragm Accumulator STDA SeriesTechnical Data

    Diaphragm Accumulators Product Information

    Main Components Standard Material Material Options

    ShellHigh Strength Alloy Steel Black Enamel Coating (Non-repairable electron-beam welded construction)

    Consult factory

    DiaphragmEco (Hydrin)

    Temperature Rating

    Consult factory for other options

    ˚C ˚F

    -40 ... +80 -40 ... +176

    NBR(Nitril-Buna-N)

    -10 ... +80 +14 ... +176

    Shut-Off Button Delrin Consult factory

    Gas Valve M28 x 1.5 US Style Gas Valve For Hermetically Sealed or other options, please consult the factory

    Fluid Port Steel Consult factory

    Size (Liters)

    Max. Recommended Flow

    Normal Operation When fully discharging

    GPM LPM GPM LPM

    0.075 & 0.16 11 40 2.6 10

    0.32 & 1.40 26 100 11 40

    2.00 & 3.50 42 160 16 60

    Electron Beam Welding

    Pressure Vessel,Lower Shell

    Fluid Port

    Clamp Ring

    Pressure VesselUpper Shell

    Poppet Valve

    Diaphragm with Poppet Valve

    MAG Welding

  • www.stauff.com 13

    Diaphragm AccumulatorsDimensions

    Diaphragm Accumulator STDA SeriesDimensions

    Nominal Size Code

    Gas Volume (in3/litre)

    Maximum Working Pressure (PSI/Bar)

    Test Pressure (PSI/Bar)

    Maximum ∆P Dynamic (PSI/Bar)

    Maximum Gas Pre-Charge (PSI/Bar)

    Maximum Compression Ratio

    Dimension (mm/in) Oil PortNet Weight (Kg/Lb)H D GFemale

    Hex(mm/in)

    0074.6 3625 5439 2031 1885

    1:8

    111 64 SAE-6 (9/16"-18)

    32 0.7

    0.075 250 375 140 130 4.35 2.52 1.25 1.54

    0169.8 3625 5439 2031 1885 119 75 SAE-6

    (9/16"-18)32 1

    0.16 250 375 140 130 4.69 2.95 1.25 2.2

    03219.5 3045 4568 1740 1885 134 92.5 SAE-8

    (3/4"-16)32 1.4

    0.32 210 315 120 130 5.28 3.64 1.25 3.08

    05030.5 3045 4568 1450 1885 151 106.7 SAE-8

    (3/4"-16)41 2

    0.5 210 315 100 130 5.95 4.2 1.61 4.4

    07545.8 3045 4568 1483 1885 166 121.5 SAE-8

    (3/4"-16)41 2.6

    0.75 210 315 93 130 6.54 4.78 1.61 5.72

    10061 3045 4568 1667 1885 180 136.2 SAE-8

    (3/4"-16)41 3.5

    1.0 210 315 115 130 7.09 5.06 1.61 7.7

    14085.4 3045 4568 2031 1885 191 147.3 SAE-8

    (3/4"-16)41 6.6

    1.4 210 315 140 130 7.52 5.8 1.61 14.52

    200122 3625 5439 2031 1885 252 156 SAE-12

    (1/16"-12)41 9.2

    2.0 250 375 140 130 9.92 6.14 1.61 20.24

    280170.9 3625 5439 2031 1885

    1:6267 174 SAE-12

    (1/16"-12)41 10

    2.8 250 375 140 130 10.51 6.85 1.61 22

    350213.6 3625 5439 2031 1885

    1:4306 174 SAE-12

    (1/16"-12)41 12.8

    3.5 250 375 140 130 12.05 6.85 1.61 28.16

    Consult the factory for additional pressure ratings and port options. Minimum order quanities may be required

    D

    H

    M28 x (1.5)

    GHex

  • 14 www.stauff.com

    STDA - 075 - NBR / P3 U M * *

    f Gas Port Connection M28 x 1.5 (Standard) M US Style Valve (Uses adaptor) U Hermetically Sealed H Note: Minimum order requirement needed for sealed gas port. Consult STAUFF.

    g Design Approval No certification Blank (1-3.6 ltr) CE Mark C Please consult STAUFF for other certifications

    h Pre-Charge (Factory filled) Factory filled during manufacture xxx pressure (Bar) NXXX

    Diaphragm Accumulator STDA SeriesOrder Codes

    c Diaphragm Material Nitrile NBR Hydrin for Low Temp ECO Fluoroelastomer FKM Other materials available on request.

    d Maximum Working Pressure 210 Bar P3 250 Bar P4 Other pressures available on request.

    e Port Options

    a Model Code STAUFF Non Repairable Diaphragm Accumulator STDA

    b Volume

    0.075 Liter / 250 Bar 0070.16 Liter / 250 Bar 0160.32 Liter / 210 Bar 0320.5 Liter / 210 Bar 0500.75 Liter / 210 Bar 0751 Liter / 210 Bar 1001.4 Liter / 210 Bar 1402 Liter / 210 Bar 2002.8 Liter / 250 Bar 2803.5 Liter / 250 Bar 350

    Other pressures available on request.

    Diaphragm Accumulators Order Code

    Connection Style Volume (Liters)

    Code Connection Type

    0.075 0.16 0.32 0.5 0.75 1 1.4 2 2.8 3.5

    U** UNF 9/16-18 9/16-18 3/4-16 3/4-16 3/4-16 3/4-16 3/4-16 1 -1/16-12 1 -1/16-12 1 -1/16-12

    B* BSPP G 1/2" G 1/2" G 1/2" G 1/2" G 1/2" G1/2" G 1/2" G 3/4" G 3/4" G 3/4"

    ** Standard for North America* Consult STAUFF for availability* Consult STAUFF for additional port options

  • www.stauff.com 15

    Diaphragm AccumulatorsCharge Kits & Gas Valve Conversion Kits

    Gas Valve Conversion Kit

    Charging Kit

    STDA-X-AKEasily converts the standard M28 X 1.5 gas valve on diaphragm accumulators to the “US Style” cored type gas valve.

    Parts included in the adapter kit:

    Aluminum Protective cap (item 7) Gas valve adapter assembly with installed gas valve core (item5) Gas Valve seal (item4) Assembly instructions

    IMPORTANT: Before installing the new gas valve, make sure the accumulator is isolated from the hydraulic system and that the gas pressure has been released from the accumulator using the proper charging kit. Please see the operating and maintenance instructions for details.

    STBA-CK-B-P3Charging kit for diaphragm accumulators with the US style cored gas valve 3625 PSI (250 bar) ratedIncludes: STBA-PC2157 Charge Valve assembly and test point SPG-063-0250-01-P-B04 Gauge 0 ... 3625 PSI (0 ... 250 bar) STBA-P3-3048MM-B 3000 PSI Nitrogen bottled adapter and hose assembly, 3048mm (12 in) long

    STBA-50019 Fitting Adaptor, .305-32 UNS (female) to 5/8"-18-2AUNF(Male)

    STBA-10143 Fitting Adaptor, 7/8"-14 UNF (female) to 5/8"-18-2AUNF (Male)

    STBA-C-1 Case with foam

    STDA-CK-M-P3Charging kit for diaphragm accumulators with the M28 X 1.5 gas Valve 3625 PSI (250 bar) ratedIncludes: STDA-PCM2155 Charge Valve assembly and test point SPG-063-0250-01-P-B04 Gauge 0 ... 3625 PSI (0 ... 250 bar) STBA-P3-3048MM-B 3000 PSI Nitrogen bottled adapter and hose assembly, 3048mm (12 in) long

    STDA-AW6MM 6 mm hexagon wrench STBA-C-1 Case with foam

    DISCARD

  • 16 www.stauff.com

    Accumulator Brackets Type AMP & AMP/D

    Type AMP Type AMP/D

    Accumulator Brackets Dimensions

    STAUFF Clamp Part Number

    Dimensions (mm/in)

    “øD” Nom A B C H L (Slot) Width

    AMP108108 138 100 150 64 9.7 X 12.7 32

    4.25 5.43 3.94 5.91 2.52 .38 X .50 1.25

    AMP114114 134 100 170 73 9.7 X 12.7 32

    4.50 5.26 3.94 6.68 2.87 .38 X .50 1.25

    AMP126126 175 136 181 77 9.7 X 12.7 32

    4.96 6.89 5.35 7.12 3.03 .38 X .50 1.25

    AMP146146 168 136 197 89 9.7 X 12.7 32

    5.75 6.63 5.35 7.75 3.50 .38 X .50 1.25

    AMP172172 191 153 229 100 9.7 X 12.7 32

    6.75 7.50 6.02 9.00 3.94 .38 X .50 1.25

    AMP206206 254 208 248 115 9.7 X 12.7 32

    8.11 10.00 8.20 9.75 4.53 .38 X .50 1.25

    AMP231231 254 208 274 125 9.7 X 12.7 32

    9.10 10.00 8.20 10.80 4.93 .38 X .50 1.25

    STAUFF Clamp Part Number

    Dimensions (mm/in)

    “øD” Nom A B C H K L Width

    AMP/D206206 260 208 230 118 275 15.0 38

    8.11 10.24 8.19 9.06 4.65 10.83 0.59 1.50

    AMP/D210213 270 216 238 123 285 15.0 38

    8.39 10.63 8.50 9.37 4.84 11.22 0.59 1.50

    AMP/D219219 268 216 242 123 285 15.0 38

    8.63 10.55 8.50 9.53 4.84 11.22 0.59 1.50

    AMP/D228232 254 216 251 126 317 15.0 38

    9.12 10 8.50 9.89 4.95 12.48 0.59 1.50

    AMP/D254248 264 216 267 135 330 15.0 38

    9.75 10.40 8.50 10.50 5.31 13.00 0.59 1.50

    AMP/D286286 332 280 315 163 355 15.0 38

    11.26 13.07 11.02 12.40 6.42 13.98 0.59 1.50

    AMP/D310310 332 280 334 170 380 15.0 38

    12.20 13.07 11.02 13.15 6.69 14.96 0.59 1.50

    AMP/D362359 427 365 383 195 424 15.0 38

    14.13 16.80 14.35 15.08 7.68 16.70 0.59 1.50

    BA

    H

    H

    C

    C

    A K

    L B

    øL

  • www.stauff.com 17

    Base Brackets & Rubber RingsTechnical Data & Dimensions

    Type BB & RR Series

    Base Bracket with Rubber Ring(to specify base bracket less rubber ring remove “R” from model number)

    Rubber Ring Only

    Specifications Rubber Bushing to reduce vibration and noise Compensation for thermal expansion and contraction Galvanized to resist corrosion Special sizes and designs are available upon request

    ModelDimensions (mm/in) Weight

    (kg/lbs)A B C D E F G H L

    BB120R260 200 100 120 75 35 225 100 17 2.3

    10.24 7.87 3.94 4.72 2.95 1.38 8.86 3.94 .67 5.1

    BB170R260 200 100 170 75 35 225 123 17 2.0

    10.24 7.87 3.94 6.69 2.95 1.38 8.86 4.84 .67 4.5

    BB211R390 270 240 211 7.09 60 390 195 22 7.7

    15.35 10.63 9.45 8.31 60 2.36 15.35 7.68 .87 16.9

    ModelDimensions (mm/in) Use with Base

    Bracket No.A B C D E F

    RR108150 120 119 108 20 15

    BB-1205.91 4.72 4.69 4.25 0.79 0.59

    RR160200 170 169 159 20 15

    BB-1707.87 6.69 6.65 6.26 0.79 0.59

    RR200250 220 210 200 25 20

    BB-2119.84 8.66 8.27 7.87 0.98 0.79

    E

    D

    A

    C

    B

    B

    øL

    AG

    HBD

    CE

    F

  • 18 www.stauff.com

    Mounting Brackets Compatibility Information for Bladder Accumulators

    Mounting Brackets Compatibility Information for Piston Accumulators

    Base Brackets & Rubber Rings General Information

    For 3000 PSI Bladder Accumulators

    Bladder Accumulator Size

    Clamp Number Qty.

    Nominal Diameter (mm/in)

    Base Bracket

    1 Quart AMP114 1114

    None4.50

    1 Gallon AMP172 1171

    BB120R6.75

    2.5 Gallon AMP/D228 1231

    BB170R9.10

    5 Gallon AMP/D228 2231

    BB170R9.10

    10 Gallon AMP/D228 2231

    BB170R9.10

    11 Gallon AMP/D228 2231

    BB170R9.10

    15 Gallon AMP/D228 3231

    BB170R9.10

    Piston Accumulator Size

    Clamp Number Qty.

    Diameter (mm/in) Base Bracket

    1 Quart AMP114 1114

    None4.50

    2 Quart AMP114 1114

    None4.50

    1 Gallon

    AMP114 1114

    None4.50

    AMP146 2140

    None5.5

    AMP172 1178

    BB120R7.0

    1.5 Gallon

    AMP114 2114

    None4.50

    AMP146 2140

    None5.5

    AMP172 1178

    BB120R7.0

    2 Gallon AMP114 1114

    None4.50

    2.5 Gallon

    AMP146 2140

    None5.5

    AMP172 1178

    BB120R7.0

    AMP/D206 1203

    BB170R8.0

    3 Gallon

    AMP146 2140

    None5.5

    AMP172 1178

    BB120R7.0

    AMP/D206 1203

    BB170R8.0

    4 Gallon

    AMP146 2140

    None5.5

    AMP172 1178

    BB120R7.0

    AMP/D206 1203

    BB170R8.0

    For 5000 PSI Bladder Accumulators

    Bladder Accumulator Size

    Clamp Number Qty.

    Nominal Diameter (mm/in)

    Base Bracket

    1 Quart AMP126 1126

    None4.96

    1 Gallon AMP172 1180

    BB120R7.00

    2.5 Gallon AMP/D254 1248

    BB170R9.75

    5 Gallon AMP/D254 2248

    BB170R9.75

    10 Gallon AMP/D254 2248

    BB170R9.75

    15 Gallon AMP/D254 3248

    BB170R9.75

    Bladder Accumulator Size

    Clamp Number Qty.

    Diameter (mm/in) Base Bracket

    5 Gallon

    AMP146 3140

    None5.5

    AMP172 2178

    BB170R7.0

    AMP/D206 1203

    BB170R8.0

    AMP/D228 1228

    BB170R9.0

    7.5 Gallon

    AMP/D206 2203

    BB170R8.0

    AMP/D228 1228

    BB170R9.0

    10 Gallon

    AMP/D206 2203

    BB170R8.0

    AMP/D228 2228

    BB170R9.0

    15 Gallon

    AMP/D206 2203

    BB170R8.0

    AMP/D228 2228

    BB170R9.0

    17.5 Gallon AMP/D228 2228

    BB170R9.0

    20 Gallon

    AMP/D206 3203

    BB170R8.0

    AMP/D228 3228

    BB170R9.0

    23 Gallon AMP/D228 3228

    BB170R9.0

    25 Gallon AMP/D228 3228

    BB170R9.0

  • www.stauff.com 19

    Round Steel U-Bolt ClampsDimensions & Order Code

    Round Steel U-Bolt ClampsType RBD

    ø D

    L

    H2

    H1

    G

    A

    Round Steel U-Bolt (type RBD)

    Order Codes

    Clamp Assembly *RBD*W1*A 30

    One clamp assembly is consisting of one Round Steel U-Bolt(type RBD) and two Nuts (to DIN EN ISO 4032).

    * Clamp Assembly (as listed above) RBD* Material code Carbon Steel, untreated W1 Carbon Steel, zinc-plated and thick-film passivated

    W66

    * Dimension A (mm) A 30

    Please note: All items are supplied non-assembled.

    Diameter Outside Diameter Nominal Dimensions (mm/in)Nominal Pipe / Tube Bore

    Ø D1 Pipe Round Steel U-Bolt (Type RBD)DN (mm) (in) (in) A L H1 H2 Thread G

    2025 .98 30

    40 70 40M10

    1.57 2.76 1.57

    26,9 1.06 3/4 1.1840 70 40

    M101.57 2.76 1.57

    2530 1.18 38

    48 76 40M10

    1.89 2.99 1.57

    33,7 1.33 1 1.5048 76 40

    M101,89 2.99 1.57

    3238 1.50 46

    56 86 50M10

    2.20 3.39 1.97

    42,4 1.69 1-1/4 1.8156 86 50

    M102.20 3.39 1.97

    4044,5 1.76 52

    62 92 50M10

    2.44 3.62 1.97

    48,3 1.90 1-1/2 2.0562 92 50

    M102.44 3.62 1.97

    5057 2.28 64

    76 109 50M12

    2.99 4.29 1.97

    60,3 2.41 2 2.5276 109 50

    M122.99 4.29 1.97

    65 76,1 3.04 2-1/282 94 125 50

    M123.23 3.70 4.92 1.97

    80 88,9 3.56 394 106 138 50

    M123.70 4.17 5.43 1.97

    100108 4.32 120

    136 171 60M12

    5.35 6.73 2.36

    114,3 4.57 4 4.72136 171 60

    M165.35 6.73 2.36

    125133 5.32 148

    164 191 60M16

    6.46 7.52 2.36

    139,7 5.59 5 5.83164 191 60

    M166.46 7.52 2.36

    150159 6.36 176

    192 217 60M16

    7.56 8.54 2.36

    168,3 6.73 6 6.93192 217 60

    M167.56 8.54 2.36

    175 193,7 7.75202 218 249 60

    M167.96 8.58 9.80 2.36

    200216 8.64 228

    248 283 70M20

    9.76 11.14 2.76

    219,1 8.76 8 8.98248 283 70

    M209.76 11.14 2.76

    250267 10.68 282

    303 334 70M20

    11.93 13.15 2.76

    273 10.92 10 11.10302 334 70

    M2011.89 13.15 2.76

    300318 12.72 332

    352 385 70M20

    13.86 15.16 2.76

    323,9 12.96 12 13.07352 385 70

    M2013.86 15.16 2.76

    350355,6 14.22 14 378

    402 435 70M24

    15.83 17.13 2.76

    368 14.72 14.88402 435 70

    M2415.83 17.13 2.76

    400406,4 16.26 16 428

    452 487 70M24

    17.80 19.17 2.76

    419 16.76 16.85452 487 70

    M2417.80 19.17 2.76

    500508 20.32 20 530

    554 589 70M24

    21.81 23.19 2.76

    521 20.84 20.87554 589 70

    M2421.81 23.19 2.76

  • 20 www.stauff.com

    Operating and Maintenance Instructions

    Bladder Accumulators Operating & Maintenance Instructions

    Installation

    The accumulator in a hydraulic circuit should be placed as near as practical to the source of shock or potential energy requirement.

    All accumulators will be shipped from the factory with a nominal pre-charge pressure. This is done to seat the accumulator poppet valve on the hydraulic port and too keep the accumulator bladder inflated at all times.

    Keep the accumulator hydraulic port covered until you are ready to make the hydraulic connection. This is done to keep out any foreign or contaminating material from the accumulator.

    Normally an accumulator should be installed in a vertical position with the oil port connection facing down. If required, it may be installed no more than within 25° of vertical with the hydraulic port facing downward. Bladder type accumulators not mounted vertical have an increased risk of the bladder floating, which traps usable fluid inside. The bladder can be pinched by the poppet valve closing, which may rupture the bladder. A non-vertical accumulator position requires more care when draining the fluid from the accumulator.

    When installing an accumulator and using “U” bolt type clamps, care should be exercised so as not to distort the accumulator with excessive force.

    Welding hangers to the accumulator is not recommended. Mounting brackets, bases and rubber rings are available from STAUFF, (See accumulator accessories pages 16-18).

    The hydraulic fluid used must be kept free of foreign matter to prevent damaging the accumulator. For maximum seal and accumulator life, the fluid should be filtered to 10 microns or better.

    It is not advisable to change the hydraulic fluid from that for which the accumulator was originally purchased for, without first checking its compatibility with the accumulator seals and bladder materials.

    Pre-Charging ProcedureGeneral Information

    The condition of the accumulator is primarily determined by periodically checking the pre-charge pressure.

    Hydraulic accumulators are pressure vessels and only qualified personnel should perform any maintenance.

    Drain all fluid completely from accumulator before performing any maintenance.

    The most accurate pre-charge readings can only be taken when the fluid pressure is at “0 psig”.

    Always observe the maximum working pressure and operating temperature ranges of the accumulator.

    CAUTION - DO NOT weld, braze or machine directly on the accumulator shell.

    CAUTION - DO NOT use automotive type valve cores with high pressure accumulator gas valves.

    CAUTION - DO NOT use the gas valve or the fluid port assembly as lifting points.

    CAUTION - DO NOT use oxygen or air for precharging the accumulator due to risk of explosion, USE only dry 99.99% pure nitrogen for charging accumulators.

    DO NOT USE OXYGEN FOR PRE-CHARGING THE ACCUMULATOR!

  • www.stauff.com 21

    Bladder AccumulatorsOperating & Maintenance Instructions

    Parts Breakdown3000 PSI Bottom Repairable, 1 Qt.

    Item Description

    1 Protective Cap

    2 Bladder Nut

    3 Gas Valve Cap

    4 Gas Valve Core

    5 Gas Valve Core Seal

    6 Name Plate

    7 Shell

    8 Bladder

    9 Poppet Valve

    10 Poppet Spring

    11 Oil Port

    12 Anti Extrusion Ring

    13 Metal Back up Ring

    14 O-Ring

    15 Back up Ring

    16 Poppet Piston

    17 Poppet Lock Nut

    18 Flange Washer

    19 Locking Ring

    Please see page 10 for replacement bladder kit part numbers.

    Replacement bladder kits includes items: 3, 4, 5, 8, 12, 13, 14

    Replacement Gas valveCoreReplacement gas valve for the 3000 PSI 1 Qt accumulators

    Gas Valve Core part NumberSTDA-X-VC

    Includes items:3, 4, 5

    Note: The complete gas valve assembly is included with STAUFF replacement bladder kits

    10

    12

    13 14

    11

    16

    7

    18

    3

    4 5

    6

    7

    8

    9

    15

    17

    19

    1

    2

  • 22 www.stauff.com

    Parts Breakdown3000 PSI Bottom Repairable, 1 to 15 Gallon, Standard and High Flow

    Bladder Accumulators Operating & Maintenance Instructions

    Item Description

    1 Protective Cap

    2 Bladder Nut

    3 Gas Valve Cap

    4 Gas Valve Core

    5 Gas Valve Core Seal

    6 Gas Valve Body

    7 Gas Valve O-Ring

    8 Name Plate

    9 Shell

    10 Bladder

    11 Poppet Valve

    12 Poppet Spring

    13 Oil Port

    14 Bleed Plug

    15 Bleed Plug Seal

    16 Anti Extrusion Ring

    17 Metal Back up Ring

    18 O-Ring

    19 Back up Ring

    20 Poppet Piston

    21 Poppet Lock Nut

    22 Flange Washer

    23 Locking Ring

    Please see page 10 for replacement bladder kit part numbers.

    Replacement bladder kits includes items: 3, 4, 5, 6, 7, 10, 17, 1, 19

    Replacement Gas Valve Core

    Replacement gas valve for the 3000 PSI accumulators 1 gallon to 15 Gallon

    Cored Valve Cartridge Part Number STA-AS-GV-1-15-P3

    Includes items:3, 4, 5, 6, 7

    Note: The complete gas valve assembly is included with STAUFF replacement bladder kits23

    23

    54

    6

    8

    9

    10

    11

    12

    13

    14

    1516

    17

    1819

    20 21

    9

    24

    1

    7

  • www.stauff.com 23

    Parts Breakdown3000 PSI Top Repairable, 2.5 to 15 Gallon

    Item Description

    1 Protective Cap

    2 Bladder Nut

    3 Gas Valve Cap

    4 Gas Valve Core

    5 Gas Valve Core Seal

    6 Gas Valve Body

    7 Gas Valve O-Ring

    8 Top Locking Ring

    9 Top Flange Washer

    10 Shell

    11 Back up Ring

    12 O-Ring

    13 Metal Back up Ring

    14 Anti Extrusion Ring

    15 Top Adapter

    16 Bladder

    17 Poppet Valve

    18 Poppet Spring

    19 Oil Port

    20 Bleed Plug

    21 Bleed Plug Seal

    22 Poppet Piston

    23 Poppet Lock Nut

    24 Flange Washer

    25 Locking Ring

    Please see page 10 for replacement bladder kit part numbers.

    Replacement bladder kits includes items (1 ea.): 3, 4, 5, 6, 7, 11, 12, 13, 16

    Replacement Gas Valve

    Replacement gas valve for the 3000 PSI accumulators 1 gallon to 15 Gallon

    Cored Valve Cartridge Part Number STA-AS-GV-1-15-P3

    Includes items:3, 4, 5, 6, 7

    Note: The complete gas valve assembly is included with STAUFF replacement bladder kits

    Bladder AccumulatorsOperating & Maintenance Instructions

    2310

    24

    23

    45

    67

    89

    1112

    1314

    15

    16

    17

    18

    19

    20

    21

    1312

    1122

    25

    10

    1

    14

  • 24 www.stauff.com

    Pre-Charging3000 PSI Bladder Accumulators

    Bladder Accumulators Operating & Maintenance Instructions

    1. Isolate the accumulator from the system and make sure hydraulic fluid pressure is zero.

    2. Remove the gas valve protection guard and then the gas valve cap from the accumulator (for top repairable accumulators connect a gas valve extension unit similar to Stauff Part # STA-VLV-EXT-1 at this time).

    3. To charge the accumulator, use a charging hose and gauge assembly similar to Stauff Charging Kit # STBA-CK-B/T-P3 rated for 3,000 psig minimum (higher pressure kits are available).

    4. Before using the charging assembly (Figure 1.) make sure that valve A is completely open (counter-clockwise), ensure that bleed valve B (Figure 1.) is completely closed (clockwise) and that the non-return valve C (Figure 1.) is capped.

    5. Connect the charging unit to the gas fill valve or gas valve extension unit (for top repairable) on the accumulator by means of knurled cap D (Figure 1.).

    6. Make sure the valve on the nitrogen bottle is completely closed, then fit the nitrogen gas valve adapter/hose assembly (included in Stauff charging kit # STBA-CK-B/T-P3) onto the nitrogen bottle (Figure 2.).

    7. Connect the other end of gas hose to the non-return valve C (Figure 1.), after taking off the cap.

    8. Turn valve A (Figure 1.) clockwise until it stops (Do not over Torque).

    9. SLOWLY open the valve on nitrogen bottle (Figure 2.) and allow the nitrogen gas to flow into the accumulator. The pressure gauge should begin to register pressure.

    10. Once the desired gas pre-charge pressure has been reached, close valve on nitrogen bottle (Figure 2.). The pressure should be slightly higher than the desired pre-charge pressure.

    11. Open valve A (Figure 1.) (Fully counter-clockwise) to bleed the trapped pressure inthe gas line to zero by means of bleed valve B (Figure 1.), open valve B (turn counterclockwise)until gauge reads 0 psig.

    12. Remove hose from non-return valve C (Figure 1.) and replace cap.

    13. Close the bleed valve B (Figure 1.) and wait a few minutes for pressure to stabilize.

    14. Screw valve A (Figure 1.) clockwise until pressure can be read on gauge. This should be slightly higher than the required pressure.

    15. Adjust to desired pressure by means of bleed valve B (Figure 1.), then remove charging unit from the accumulator gas valve and from the nitrogen bottle (after making sure that the nitrogen bottle valve is completely closed.

    16. If necessary remove the gas valve extension unit (top repairable accumulators only), then reinstall the gas valve cap and protective guard cap on the accumulator. The accumulator is now ready for use.

    NOTE: Allow the accumulator to rest approximately 10-15 minutes after gas pre-charging.This will allow gas temperature to adjust and equalize. Recheck gas pressure and adjust if necessary. Check accumulator gas valve for any leaks with soapy water. Always wear safely glasses.

    Figure 1. Figure 2.

    A

    C

    D

    B

  • www.stauff.com 25

    Checking Pre-Charge Pressure3000 PSI Bladder Accumulators

    Bladder AccumulatorsOperating & Maintenance Instructions

    General Information

    The condition of the accumulator is primarily determined by periodic checking of pre-charge pressure. Only qualified personnel should perform any maintenance on accumulators. Nitrogen gas pre-charge pressure should be checked at least once during the first week of operation toassure that no leak has developed. The pre-charge pressure and ambient temperature should be recorded at installation. If there is no loss of gas pre-charge pressure, it should be rechecked in approximately 4 months. Thereafter, it should be checked annually. Check pre-charge if thesystem is acting sluggishly. If pre-charge is low, check the gas valve for leakage and recharge.

    Pre-Charge Checking Procedure for 3000 PSI Bladder Accumulators.

    1. Use appropriate valving in the hydraulic system, to discharge all hydraulic fluid from accumulator.

    2. To check or adjust pre-charge pressure, HYDRAULIC PRESSURE MUST BE REDUCTED TO 0 PSIG. Pre-charge pressure should be checked periodically. Charging and checking should be done with an accumulator charge assembly kit similar to Stauff Part # STBA-CK-B/T-P3.

    3. Follow pre-charging instructions for 3000 psi bladder accumulators - instructions #4through #15.

    4. If necessary remove the gas valve extension unit (top repairable accumulatorsonly), then reinstall the gas valve cap and protective guard cap on the accumulator.The accumulator is now ready for use.

    NOTE: Allow the accumulator to rest approximately 10-15 minutes after gas pre-charging. This will allow gas temperature to adjust and equalize. Recheck gas pressure and adjust if necessary. Check accumulator gas valve for any leaks with soapy water. Always wear safely glasses.

    Figure 1.

    A

    C

    D

    B

  • 26 www.stauff.com

    Parts Breakdown5000 PSI Bottom Repairable, 2.5 to 15 Gallon

    Bladder Accumulators Operating & Maintenance Instructions

    Item Description

    1 Protective Cap

    2 Bladder Nut

    3 Gas Valve Cap

    4 Gas Valve

    5 Gas Valve O-Ring

    6 Name Plate

    7 Shell

    8 Bladder

    9 Poppet Valve

    10 Poppet Spring

    11 Oil Port

    12 Bleed Plug

    13 Bleed Plug Seal

    14 Anti Extrusion Ring

    15 Metal Back up Ring

    16 O-Ring

    17 Back up Ring

    18 Poppet Piston

    19 Poppet Lock Nut

    20 Flange Washer

    21 Locking Ring

    Please see page 10 for replacement bladder kit part numbers.

    Replacement bladder kits includes items: 3, 4, 5, 8, 15, 16, 17

    Replacement Gas Valve Core

    Replacement gas valve for the 5000 PSI accumulators 2.5 gallon to 15 Gallon

    Cored Valve Cartridge Part Number STA-AS-GV-1-15-P5

    Includes items:3, 4, 5

    Note: The complete gas valve assembly is included with STAUFF replacement bladder kits

    197

    20

    3

    45

    6

    7

    8

    9

    10

    11

    12

    13

    1516

    1718

    21

    2

    1

    14

  • www.stauff.com 27

    Pre-Charging5000 PSI Bottom Repairable Bladder Accumulators

    Bladder AccumulatorsOperating & Maintenance Instructions

    Pre-Charging Procedure for 5000 PSI Bottom Repairable Bladder Accumulators.

    1. Isolate the accumulator from the system and make sure hydraulic fluid pressure is zero.

    2. Remove the gas valve protection guard and then the gas valve cap from the accumulator.

    3. To charge the accumulator, use a charging hose and gauge assembly similar to Stauff Charging Kit # STBA-CK-B-P5, rated for 5,000 psig minimum.

    4. Before using the charging assembly (Figure 1.) make sure that valve A is completely open (counter-clockwise), that bleed valve B (Figure 1.) is completely closed ( clockwise) andthat the non-return valve C (Figure 1.) is capped.

    5. Connect the charging unit to the 5000 psi gas fill valve on the accumulator bymeans of knurled cap D (Figure 1.).

    6. Open the gas valve adapter on the accumulator (referring to the 5000 PSI gas valve STA-AS-GV-1-15-P5) by securing the bottom hex on the gas valve with one (1) wrench whileunscrewing the top hex on the gas valve (counter clockwise) with a second (2) wrench. This will open the poppet inside the gas valve. Note, four (4) turns should fully open the poppet.

    7. Make sure the valve on the nitrogen bottle is completely closed, then fit the 5000 PSI nitrogen gas valve adapter/hose assembly (included in Stauff Charging Kit # STBA-CK-B-P5 ) onto the nitrogen bottle (Figure 2.).

    8. Connect the other end of the gas hose to the non-return valve C (Figure 1.), after taking off its cap.

    9. Turn valve A (Figure 1.) clockwise until it stops (Do not over Torque).

    10. SLOWLY open the valve on nitrogen bottle (Figure 2.) and allow the nitrogen gas to flow to the accumulator. The pressure gauge should begin to register pressure.

    11. Once the desired gas pre-charge pressure has been reached, close valve on nitrogen bottle (Figure 2.).

    12. Open valve A (Figure 1.) (Fully counter-clockwise) and bleed the trapped pressure in the gas line to zero by means of bleed valve B (Figure 1.), open valve B (turn counterclockwise)until gauge reads 0 psig.

    13. Remove hose from non-return valve C (Figure 1.) and replace cap.

    14. Close the bleed valve B (Figure 1.) and wait a few minutes for pressure to stabilize.

    15. Screw valve A (Figure 1.) clockwise until pressure can be read on gauge. This should beslightly higher than the required pressure.

    16. Adjust to desired pressure by means of bleed valve B (Figure 1.), then, with a wrench screw in the top hex on the accumulator gas valve until tight, then remove charging unit from the accumulator gas valve and from the nitrogen bottle (after making sure that the nitrogen bottle valve is completely closed.

    17. Reinstall the gas valve cap and protective guard cap on the accumulator. The accumulator is now ready for use.

    NOTE: Allow the accumulator to rest approximately 10-15 minutes after gas pre-charging. This will allow gas temperature to adjust and equalize. Recheck gas pressure and adjust if necessary. Check accumulator gas valve for any leaks with soapy water. Always wear safely glasses.

    Figure 2.Figure 1.

    A

    C

    D

    B

  • 28 www.stauff.com

    Checking Pre-Charge Pressure5000 PSI Bladder Accumulators

    Bladder Accumulators Operating & Maintenance Instructions

    General Information

    The condition of the accumulator is primarily determined by periodic checking of pre-charge pressure. Only qualified personnel should perform any maintenance on accumulators. Nitrogen gas pre-charge pressure should be checked at least once during the first week of operation toassure that no leak has developed. The pre-charge pressure and ambient temperature should be

    Pre-charge Checking Procedure for 5000 PSI Bladder Accumulators

    1. Use appropriate valving in the hydraulic system, to discharge all hydraulic fluid from accumulator.

    2. To check or adjust pre-charge pressure, HYDRAULIC PRESSURE MUST BE REDUCTED TO 0 PSIG. Pre-charge pressure should be checked periodically. Charging and checking should be done with an accumulator charge assembly kit similar to Stauff Part # STBA-CK-B-P5.

    recorded at installation. If there is no loss of gas pre-charge pressure, it should be rechecked in approximately 4 months. Thereafter, it should be checked annually. Check pre-charge if thesystem is acting sluggishly. If pre-charge is low, check the gas valve for leakage and recharge.

    3. Follow pre-charging instructions for 5000 psi bottom repairable bladderaccumulators - instructions #4 through #16.

    4. Reinstall the gas valve cap and protective guard cap on the accumulator. The accumulator is now ready for use.

    NOTE: Allow the accumulator to rest approximately 10-15 minutes after gas pre-charging. This will allow gas temperature to adjust and equalize. Recheck gas pressure and adjust if necessary. Check accumulator gas valve for any leaks with soapy water. Always wear safely glasses.

    Figure 1.

    A

    C

    D

    B

  • www.stauff.com 29

    Disassembly Procedures for Bladder Accumulators

    Bladder AccumulatorsOperating & Maintenance Instructions

    Bladder Accumulators are Pressure Vessels and are fundamentally hazardous because they store energy in the form of compressed Gas and pressurized Fluid . Only people who have had the appropriate training with regard to disassembly of Accumulators should attempt to dismantle an Accumulator.

    Note: Prior to disassembly of the Accumulator please ensure the following are checked first.

    A. The pre-charge pressure is released from the Accumulator and there is no gas pressure left in the Accumulator. Use an appropriate pre-charging head connected to the Gas Valve and check to see that the gauge reads zero pressure. Open up the bleed valve on the charging head and make sure no gas can be heard coming from the Accumulator. (See Stauff Pre-Charging Instructions Pgs. 20 - 28).

    B. Check to make sure that the poppet valve located in the Fluid Port is fully in the open position. (see Figure 4a.)

    Note - in cases where the poppet valve is still in the closed position and the stem is extended (out position), do not attempt toservice the vessel and contact the manufacturer.

    C. Where possible check to make sure that any potential system fluid still in the Accumulator is not dangerous or can cause harmif it comes into contact with human skin, especially phosphate ester fluids. If necessary wear protective clothing.

    Disassembly Instructions

    1. Remove the Protection Cap.

    4. Ensure that the poppet valve is not closed. The stem should be fully in and free to move.

    2. Remove the Gas Valve Assembly Cap.

    5. Remove the Gas Valve Assembly or Gas Valve Core.

    3. Attach STAUFF pre-charging head and release any pre-charge from the Accumulator.

    6. Remove the Bladder Lock Nut and Name Plate.

    Shell

    Shell

    Bladder

    Bladder

    Poppet Valve Open

    Poppet Valve Open

    Figure 4a.

  • 30 www.stauff.com

    Disassembly Intructions

    Bladder Accumulators Operating & Maintenance Instructions

    11. Remove as much air as possible from the Bladder, then remove the bladder from the Shell - do not use any sharp objects that could damage the bladder.

    10a. Remove the Fluid Port Assy by first pushing the Fluid Port back into the inside of the shell.

    10b. From inside the shell slide the Anti extrusion ring off the Fluid Port body and remove from the shell.

    10c. The Fluid Port can then be removed from the shell.

    7. Remove the Bleed Valve on the Fluid Port. 8. Remove the Fluid port Lock Nut with an appropriate “C” spanner along with the flanged washer.

    9. Remove the Nylon Back-up Washer along with the O-Ring.

    12. Inspect the Bladder.

    In cases where there are signs of damage, wear or swelling then the Bladder should be replaced.

    Refer to page 31 and 32. outlining potential Damages, Causes and Response.

  • www.stauff.com 31

    Bladder Accumulators

    Trouble Shooting Guide

    Operating & Maintenance Instructions

    Type of Damage Cause Response

    External Leakage from Gas Valve

    Any leakage from the gas valve if not detected will eventually lead to bladder failure.

    Any loss of Nitrogen from the gas valve will cause the compression ratio on the bladderto be exceeded and eventually cause the bladder to fail.

    Always ensure that after pre-charging, or du-ring service intervals where the pre-chargeis checked, that the gas valve is inspected for leaks.

    Severe leakage from the Gas Valve Gas valve assembly or valve core damaged.In-correct charge valve used – gas valve has been tampered with.

    Replace Gas Valve.Ensure the correct charging equipment is used.

    External Leakage from Fluid Port

    Leaking Oil between Fluid Port body and Accumulator Shell.

    Damaged O-Ring caused during assembly or O-Ring has become hard due to High Oiltemperatures.

    Replace Fluid Port O-Ring.Check Assembly MethodsCheck oil system temperature.

    Internal Leakage from Bladder

    Upon pre-charge and less than 29 PSI (2 bar) the Bladder fails leaving a star shape burstpattern at the bottom of the Bladder.

    The Accumulator was not lubricated properly and / or pre-charged too quickly.Excessive stretching of the bladder or the lower regionhas been caught in the poppetvalve.

    Replace Bladder.Ensure that the Shell and Bladder are well lubricated with system fluid.Pre-charge very slowly until the poppet valve is closed.

    Bladder has abrasion lines on 1, 2 or 3 sides. There is a failure along one of marked lines.

    The compression ratio between Max. and Min.pressure is too high. The pre-charge pressure is too low or has not been checked for along time.Gas permeation is an issue.

    Replace Bladder.Ensure that the compression ratio is below 4:1 – Check pre-charge pressure more frequently.Replace with Bladder that has a higher acrolynitrile percentage.

    Bladder has failed at the bonded seam – Vulcanizing failure.

    Bladder has rubbed on the inside of the shell due to the compression ratio too high.Manufacturing or Material fault.

    Replace Bladder.Ensure that the compression ratio is below 4:1Check pre-charge pressure more frequently.

    Bladder has Circular cut mark on the base. Pre-charge pressure is too high. Lower Pre-charge pressure.

    Bladder has a pin hole around the tip of the Bladder.

    Loss of pre-charge pressure, leaking gas valve, the pre-charge pressure has notbeen checked.

    Check / replace gas valveCheck pre-charge more frequently.

    O’Ring

  • 32 www.stauff.com

    Type of Damage Cause Response

    Internal Leakage from Bladder

    Bladder has hardened and is carbonized. Accumulator cycle time is very quick along with a very high compression ratio, causinghigh gas temperature.Oil temperature is too high..

    Replace Bladder,Check Accumulator cycle time and reduce or increase size of Accumulator.Ensure oil temperature is lowered to the correct level.

    Bladder is swollen. Incorrect bladder material.System fluid is not compatible with the bladder material.

    Check compatibility of the bladder material with the fluid used.Consult Accumulator manufacturer.

    Anti- Extrusion Ring

    Anti-Extrusion Ring has split into two halves after disassembly.

    Normal wear and tear. Re-place Anti-Extrusion Ring.

    Fluid Port Assembly

    Worn Poppet Valve.Excessive side movement in the poppet valve or poppet valve is sticking when pusheddown.

    Normal Wear.Poppet valve is operated during each cycle.The pre-charge is too close or higher than the minimum working pressure.The flow rate from the accumulator is above the recommend flow rate for that model.

    Replace Fluid Port Assy.Ensure pre-charge pressure is lowered to

  • www.stauff.com 33

    Assembly Procedures for Bladder Accumulators

    Bladder AccumulatorsAssembly Procedures

    Note: Prior to assembly of the Accumulator please ensure the following are checked first.

    A. Always ensure that the Assembly is done in a clean area.

    B. Make sure that the replacement Bladder is designed and sized for Accumulator being repaired.

    C. Ensure that any system fluid still inside the Accumulator is not dangerous to the human skin. (Wear protective clothing if necessary).

    D. Make sure there is no internal or external corrosion on the Accumulator or any evidence of damage to the shell prior to assembling the Accumulator.

    E. It is the responsibility of the person doing the repair to ensure that the Accumulator complies with any relevant government requirements, such as Design and Inspection criteria.

    If there is any doubt with regard to D. and E. above, the Accumulator should not be reassembled and preferably discarded.

    Assembly Instructions

    1. Ensure that the inside of the Shell is well lubricated with System Fluid.

    Note: In some cases Standard Hydraulic Fluid may not becompatible with the System Fluid therefore an alternative fluid may need to be used.

    4. Place Fluid Port inside the Shell Poppet Valve facing inwards.

    2. Take Bladder and remove Gas Valve. Remove all air from theBladder and fold neatly. Position Bladder inside Accumulator so that the Bladder Stem protrudes through the small opening at the other end of the Shell.

    5. Place Anti-Extrusion Ring inside the Shell and make sure the metal ring is facing you.

    3. Fit Name Plate and Locknut to Bladder Stem.

    6. Slide the Anti-Extrusion Ring over the Fluid Port inside the Accumulator Shell.

  • 34 www.stauff.com

    Bladder Accumulators

    12. Fit the Gas Valve Assembly to the Bladder Stem and tighten to the correct setting. Ensure that when tightened the Bladder stem does not rotate.

    9. Ensuring the Fluid Port Body does not get dislodged - insert the Nylon Back-Up washer so that the rounded face on the washer faces the O-Ring.

    Note: With regard to pre-charging the Accumulator with Nitrogen, please refer to the STAUFF Pre-Charging Instructions.

    Assembly Intructions

    Accumulators & Accessories

    13. Fit the Gas Valve Assembly Cap. 14. Fit the Gas Valve Protection Cap.

    10. Attach first the Flanged washer and then the Lock-Nut. Ensure the Lock-Nut is tightened using an appropriate spanner.

    11. Fit the Bleed Plug or Test Point (if fitted) and tighten.

    7. Grip the Fluid Port Body from inside the Shell and pull out as far as possible.

    8. Holding the Fluid Port Body firmly install the O-Ring. Ensure no sharp tools are used and that the O-Ring is inserted evenly around the Fluid Port Body.

  • www.stauff.com 35

    Sizing Accumulators

    Bladder AccumulatorsSizing Data & Application

    Sizing AccumulatorsIn selecting the proper accumulator size V1 (size of accumulator in cubic inches) when Vw (volume of fluid to be discharged from accumulator) is known.

    V1 = ( Vw)(E) f

    E in the above equation adjusts the equation due to the accumulator efficiency versus the gas pre-charge pressure.Use the following constants.

    For Supplementing PumpE = 1.24 for bladder accumulators.

    For Auxiliary Power Source (No Pump)E = 1.60 for bladder accumulators.

    In the above equation the discharge coefficient “f” adjusts the equation for the change in the gas temperature due to heat gains and losses by expansion and compression of the gas (Calculate “f” as shown below).

    Adiabatic Operation

    In an adiabatic operation where the gas temperature is rapidly changing as a result of rapid compression and expansion of the gas:

    f =1– ( 1 ) 1/n (See Table 1, Page 36 for Calculations.) a

    Where:a = P3 = working pressure ratio P2

    P3 = Maximum system pressureP2 = Minimum system pressuren = Polytropic exponent for adiabatic operation (See Charts on Page 37)

    Sizing AccumulatorsIn an isothermal operation where the compression and expansion of the gas is very slow, allowing enough time for heat transfer resulting in little or no change in gas temperature.f = 1– ( 1 ) a

    Where:a = P3 = working pressure ratio P2

    P3 = Maximum system pressureP2 = Minimum system pressure

  • 36 www.stauff.com

    a Values“n” Values1.40 1.45 1.50 1.55 1.60 1.65 1.70 1.75 1.80 1.85 1.90 1.95

    1.0 0 0 0 0 0 0 0 0 0 0 0 0

    1.1 .0658 .0636 .0616 .0596 . 0578 .0561 .0545 .0530 .0516 .0502 .0489 .0480

    1.2 .1221 .1182 .1145 .1110 .1077 .1046 .1017 .0989 .0963 .0939 .0915 .0896

    1.3 .1709 .1655 .1605 .1557 .1512 .1470 .1430 .1392 .1356 .1322 .1290 .1264

    1.4 .2136 .2071 .2009 .1951 .1897 .1845 .1796 .1749 .1705 .1663 .1623 .1594

    1.5 .2515 .2439 .2369 .2302 .2239 .2179 .2122 .2068 .2017 .1968 .1922 .1887

    1.6 .2852 .2769 .2690 .2616 .2545 .2479 .2415 .2355 .2298 .2244 .2191 .2154

    1.7 .3155 .3065 .2980 .2899 .2823 .2750 .2681 .2616 .2553 .2494 .2437 .2395

    1.8 .3429 .3333 .3242 .3156 .3074 .2997 .2923 .2853 .2786 .2722 .2661 .2617

    1.9 .3677 .3577 .3481 .3391 .3305 .3223 .3145 .3070 .2999 .2932 .2867 .2819

    2.0 .3905 .3800 .3700 .3606 .3516 .3430 .3348 .3270 .3196 .3125 .3057 .3010

    2.1 .4114 .4005 .3902 .3804 .3711 .3622 .3537 .3456 .3378 .3304 .3233 .3181

    2.2 .4306 .4194 .4088 .3987 .3891 .3799 .3711 .3627 .3547 .3470 .3396 .3344

    2.3 .4484 .4370 .4261 .4157 .4058 .3964 .3873 .3787 .3704 .3625 .3549 .3493

    2.4 .4649 .4533 .442 .4315 .4214 .4117 .4025 .3936 .3851 .3770 .3692 .3634

    2.5 .4803 .4684 .4571 .4463 .4360 .4261 .4167 .4076 .3989 .3906 .3820 .3766

    2.6 .4947 .4826 .4711 .4601 .4496 .4396 .4300 .4207 .4119 .4034 .3952 .3891

    2.7 .5081 .4959 .4843 .4731 .4625 .4523 .4425 .4331 .4241 .4154 .4071 .4010

    2.8 .5207 .5084 .4966 .4854 .4746 .4642 .4543 .4448 .4356 .4268 .4184 .4120

    2.9 .5326 .5226 .5083 .4969 .4860 .4755 .4654 .4558 .4465 .4376 .4290 .4226

    3.0 .5438 .5337 .5193 .5078 .4967 ,4862 .4760 .4662 .4568 .4478 .4391 .4326

    n C3

    1.41 - 1.45 .0300

    1.46 - 1.49 .0318

    1.50 - 1.53 .0336

    1.54 - 1.57 .0352

    1.58 - 1.62 .0371

    1.63 - 1.67 .0389

    1.68 - 1.73 .0410

    1.74 - 1.79 .0429

    1.80 - 1.85 .0447

    1.86 - 1.91 .0464

    1.92 - 1.94 .0472

    Discharge Coefficient

    Bladder Accumulators Sizing Data & Application

    f =1 – ( 1 ) 1/n

    a

    Note: Use this formula if “a” is less than 1.1 or over 3.If exact values of “a” are not shown, select the next higher value (See charts below).

    Table 1

    How to Read Table 1

    Locate “a” value in left-hand column and locate “n” value at top of Table 1. The point at which “n” and “a” intersect will be the “f” value.

    Table 2

  • www.stauff.com 37

    0 - 8 Seconds

    61 - 120 Seconds

    9 - 30 Seconds

    121 - 500 Seconds

    31- 60 Seconds

    501 - 900 Seconds

    Instructions for Selection of Discharge Coefficient “n”

    Bladder AccumulatorsSizing Data & Application

    1. Determine Average System PressureP2 + P3 = Average System Pressure 2

    2. Determine the time in seconds to discharge the oil from the accumulator.

    3. Select the graph which corresponds to the time (sec.) required to discharge the accumulator.

    4. Select the curve on the graph which corresponds to the gas operating temperature (If gas temperature under operating conditions is not known assume 100 °F / 38°C.)

    5. To use the graph, locate the average system pressure along the bottom portion of the graph. Move vertically along this column until you intersect the line corresponding to the gas temperature. Then move horizontally along this line and read the discharge coefficient to the left side of the graph.

    Selection Charts for Discharge Coefficient “n”

    2.40

    2.30

    2.20

    2.10

    2.00

    1.90

    1.80

    1.70

    1.60

    1.50

    1.40

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    n

    2.30

    2.20

    2.10

    2.00

    1.90

    1.80

    1.70

    1.60

    1.50

    1.40

    1.30

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    n

    2.20

    2.10

    2.00

    1.90

    1.80

    1.70

    1.60

    1.50

    1.40

    1.30

    1.20

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    n

    0 ˚F / -17.8 ˚C0 ˚F / -17.8 ˚C

    0 ˚F / -17.8 ˚C

    75 ˚F / -23.9 ˚C

    75 ˚F / -23.9 ˚C100 ˚F / 37.8 ˚C

    100 ˚F / 37.8 ˚C125 ˚F / 51.7 ˚C

    125 ˚F / 51.7 ˚C

    150 ˚F / 65.6 ˚C

    150 ˚F / 65.6 ˚C

    75 ˚F / 23.9 ˚C

    100 ˚F / 37.8 ˚C

    125 ˚F / 51.7 ˚C150 ˚F / 65.6 ˚C

    2.00

    1.90

    1.80

    1.70

    1.60

    1.50

    1.40

    1.30

    1.20

    1.10

    1.00

    1.40

    1.30

    1.20

    1.10

    1.00

    1.30

    1.20

    1.10

    1.00

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    1000 2000 3000 (PSI) 68.9 137.9 206.8 (bar)

    Average System Pressure (PSI)

    n

    n

    n

    0 ˚F / -17.8 ˚C 0 ˚F / -17.8 ˚C

    0 ˚F / -17.8 ˚C75 ˚F / -23.9 ˚C

    75 ˚F / -23.9 ˚C

    75 ˚F / -23.9 ˚C100 ˚F / 37.8 ˚C

    100 ˚F / 37.8 ˚C125 ˚F / 51.7 ˚C150 ˚F / 65.6 ˚C

    125 ˚F / 51.7 ˚C

    100 ˚F / 37.8 ˚C

    150 ˚F / 65.6 ˚C 125 ˚F / 51.7 ˚C150 ˚F / 65.6 ˚C

  • 38 www.stauff.com

    Problem #1 Supplementing Pump Flow

    Bladder Accumulators Sizing Data & Application

    Given: A 4.5" bore x 10" stroke cylinder with a 2" diameter rod must extend and retract in 6 seconds. Minimum pressure required to cycle cylinder is 1000 PSI (68 bar). Dwell time between cycles is 1.5 minutes. Gas temperature is 100 °F. Maximum system pressure is 2000 PSI (136 bar).

    Information Required

    P2 = 1000 PSI (68 bar) = Minimum system pressureP3 = 2000 PSI (136 bar) = Maximum system pressureCT = 6 sec. = Cycle time of actuatorVC = 286.5 in3 = Displacement of actuator per cycleDT = 90 sec. = Dwell time between cyclesT = 100 °F. = Gas operating temperature

    Solve For:

    PC = 3.0 in3/ sec. = VC = minimum required output of pump (in3/sec) DT+CTQ = .78 GPM = .26 PC = pump output (GPM)

    Vw = 269 in3 = VC – (3.85) (Q) (CT) = cubic inches of fluid required from accumulator

    a = 2 = P3 = working pressure ratio P2

    n = 1.65 = From Page 37

    f = .3430 = From Page 36 (Table 1) (Based on values of “a” & “n”)

    Solution:

    V1 (in3) = (Vw) (E) f

    E = 1.24 for bladder accumulator (See Page 35).

    V1 (in3) = 269 (1.24) = 973 in3 or 4.25 Gallons .3430

    Where V1 = Accumulator size required in cubic inches

    Once V1 has been determined, select the accumulator from Pages 4-8 which has a gas volume equal to or greater then V1. In this example a 5 gallon bladder accumulator would satisfy the system. P = gas pre-charge, which should be 80% of P2 in bladder accumulators.

    Problem #2 Increasing Actuation Speed in an Existing Hydraulic SystemGiven: Present system has a 5 GPM pump capable of 3000 PSI (207 bar), 6” bore x 12” stroke cylinder with a 2” rod. Minimum pressure to extend and retract cylinder is 1500 PSI (103 bar). Gas temperature is 150 °F. Bladder accumulator to be used. Cylinder cycle time is to be reduced from 40 seconds to 8 seconds. Dwell time between cycles is 40 seconds.

    Information Required

    P2 = 1500 PSI (103 bar) = Minimum system pressureP3 = 3000 PSI (207 bar) = Maximum system pressureCT = 8 sec. = Cycle time of actuatorVC = 640.5 in3 = Displacement of actuator per cycleDT = 40 sec. = Dwell time between cyclesQ = 5 GPM = Present pump flowT = 150 °F. = Gas operating temperature

    Solve For:

    Vw = 486.5 in3 = VC – (3.85) (Q) (CT)

    VR = 770 in3 = (3.85) (Q) (DT) is the pump output during the dwell period. VR must be Greater than Vw to accomplish the new cycle rate. If not, cycle time (CT) or dwell time (DT) must be increased.

    a = 2 = P3 = Pressure ratio P2

    n = 1.76 = From Page 37

    f = .3196 = From Page 36 (Table 1) (Based on values of “a” & “n”)

    Solution:

    V1 (in3) = (Vw) (E) f

    E = 1.24 for bladder accumulator (See Page 35).

    V1 (in3) = 486.5 (1.24) = 1887.5 in3 or 8.2 Gallons .3196

    Where V1 = Accumulator size required in cubic inches

    Once V1 has been determined, select the accumulator from Pages 4-8 which has a gas volume equal to or greater then V1. In this example a 10 gallon bladder accumulator would satisfy the system. P = gas pre-charge, which should be 80% of P2 in bladder accumulators.

  • www.stauff.com 39

    Bladder AccumulatorsSizing Data & Application

    Solution:

    V1 (in3) = (Vw) (E) = Size of accumulator required f

    V1 = (V)2 (W) (n-1) (.205) (P2) (C3)

    V1 = (27.5)2 (42.2) (1.80-1) (.205) = 53.2 in3 or .23Gallons (2200) (.0447)

    A1 Qt. accumulator would satisfy the system.

    P1 gas pre-charge pressure should normally be 60% of P2, (in a shock suppression application).

    Problem #3 Shock Suppression

    Given: System has a 120 GPM pump operating at 2200 PSI (152 bar). Shock is caused by rapidly closing the directional control valve. 80 feet of pipe is between the pump and valve causing shock. Internal area of pipe is 1.4 square inches. Gas operating temperature is 100°F (38°C). Using standard petroleum oil (54.3 lbs/ft3). What size of accumulator (V1) would be required to limit shock pressure to 10% above system pressure P2?

    Information Required

    L = 80 ft. = Length of pipe between pump and valve causing shock.A = 1.4 in2 = Internal area of pipeP2 = 2200 PSI (152 bar) = Operating pressureQ = 120 GPM = Rate of flowT = 100 °F = Gas operating temperature

    Solve For:

    n = 1.80 = Discharge coefficient – See Page 37. Use 0-8 second curves.

    VT = 0.78 ft3 = (L) (A) = Total volume of oil in pipe 144

    WT = 54.3 lbs/ ft3 = Weight of fluid per cubic foot

    W = 42.2 lbs = (VT) (WT) = Total weight of liquid in pipe

    V = 27.5 ft/ sec. = (.3208) (Q) = Flow velocity AC3 = .0447 = From Page 36 (Table 2) (Opposite the “n” value selected)

  • 40 www.stauff.com

    Guidelines for Selection, Installation and Operation

    Diaphragm Accumulators Operating & Maintenance Instructions

    GeneralHydraulic Diaphragm Accumulators from Stauff Corporation have been in use in numerous branches of industry for many years and are proven components. Optimal function and long service life are however only achieved if specific selection criteria are observed and incorrect installations and incorrect operating conditions are avoided.

    For improved understanding of the following sections, the most importantexpressions and terms are briefly explained here.

    Operating pressureNormally the accumulator operates between P1 and P2

    P0 = pre-charge pressure (normally 90% of P1)P1 = minimum operating pressureP2 = maximum operating pressureP3 = system relieve pressure settingP4 = maximum working pressure of accumulatorPm= mean operating pressure

    Permissible excess operating pressure P4Max. pressure for which the accumulator is designed and that can be found in the technical documentation and the marking (rating plate, lettering).

    Gas filling pressureBefore the diaphragm accumulator can be installed in a hydraulic system, it must be pre-charged with dry nitrogen gas. The pre-charge pressure is normally 95% to 90% of P1 at operating temperature.

    Permissible pressure ratioP2/P0 or P3/P0 = pressure ratio < 8:1, 6:1, 4:1 depending on accumulator size. Figure stipulated by the manufacturer in relation to the compression ratio of the diaphragm accumulator, e.g. 8:1; this figure should not be exceeded (use pressure as absolute figures).

    Aspects on the selection of a diaphragm accumulatorSelection in relation to the perm. excess operating pressure P4The diaphragm accumulator is to be selected such that the permissible excess operating pressure P4, is in all circumstances above the upper operating pressure P2 to be expected and also above any pressure peaks that may occur.

    Pressure peaks or pressure increase occur, e.g., due the switching of multiway valves and the resulting retardation of oil masses, retardation of fast moving masses, pressure translation in differential circuits, etc.

    In this respect it is highlighted that pressure peaks may be so short that they can often not be measured with the aid of clamped measuring instruments such as pressure gauges. Safety valves also do not always react to such short pressure peaks.

    Correct selection of the pre-charge pressure P0The magnitude of the pre-charge pressure is dependent on the operating pressures to be expected and the type of application.

    The following figures can be used as general guidance:

    • with pulsation damping Po = 0.6 to 0.8 x Pm (Pm = mean operating pressure)

    • with surge damping or volume storage Po = 0.6 to 0.9 x P1 (p1 = lower working pressure)

    It is to be ensured that the pre-charge pressure does not exceed the value 0.9 x P1 also at the operating temperature. The pre-charge pressure established and specified at room temperature increases with increasing temperature in accordance with gas laws.

    As a rule of thumb, a pressure increase of 10% for a 30 °C (86F) temperature increase can be expected.

    If the pre-charge pressure is too low this may result in a drop in performance from the accumulator and result in high flexing loads on the diaphragm and shortened life of the diaphragm.

    Gas LossesInadequate gas pressures can also be due to gas losses as a consequence of permeation processes. As elastic separating materials are not leak-proof in the absolute sense, gas molecules pass through the membrane, are dissolved in the operating fluid and transported to the reservoir where there can again separate from the fluid. The gas losses increase proportionally with the operating pressure and exponentially with the temperature. With conditions that are otherwise the same, gas losses will result in a faster reduction of the pre-charge on smaller hydraulic accumulators than on larger accumulators.

    Estimates on possible gas losses can be determined on initial installations by monitoring the pre-charge on regular intervals. From this information it is possible to estimate maintenance intervals.

    A pre-charge pressure that is too low from the start will be further reduced by gas pressure losses, and, under operating conditions that otherwise remain the same, a diaphragm accumulator will not be able to store the same volume of fluid. Diaphragms or bladders as separating components are overloaded resulting in a reduction in the service life. The damping capacity of the hydraulic accumulator will be reduced, and any pressure peaks that occur can exceed the permissible excess operating pressure. For this reason, the magnitudes of the pre-charge pressure losses are to be checked and increased at intervals to suit the application. The check can be performed very easily by using the pre-charge kit STDA-CK-M-1.

    Correct Installation

    Safety –rel