Parameter Call-up Menus
1
Access to the Parameter Call-Up Menus Make sure that this(these) circuit breaker(s) is(are) closed:
PANEL DESIGNATION IDENT. LOCATION
121VU AIDS/DMU (AIDS & RCDR/FDIMU) 4TV(5TV) K15
A. Enter the Parameter Label Call-up through MCDU.
ACTION RESULT
On the MCDU: On the MCDU display:
- Push the MCDU MENU mode key.
- The MCDU MENU page shows. - Push the Line Select Key (LSK) adjacent to < AIDS indication.
- The AIDS page shows. - Push the LSK adjacent to CALL-UP < PARAM LAB indication.
- The AIDS PARAM LABEL CALL-UP page shows.
- Enter the Parameter Label Call-up with the alphanumeric keys in the format as follows: EQ/SYS/LAB/SDI and optional /DATABITS (Ref. AMM 31-37-00-001).
- The Parameter Label Call-up shows on the bottom of the display (scratchpad).
NOTE: It is important to enter the DATABITS value if it is other than the default. The decimal value calculation is based on its value.
-
Push the LSK 1L or 4L to take over the Parameter Label Call-up.
- The Parameter Label Call-up shows on the Data Field with all information.
- Push the MCDU MENU mode key.
- The MCDU MENU page shows. B. Enter the Parameter Alpha Call-up through the
MCDU.
ACTION RESULT
On the MCDU: On the MCDU display:
- Push the MCDU MENU mode key.
- The MCDU MENU page comes into view.-
Push the Line Select Key (LSK) adjacent to < AIDS indication.
- The AIDS page comes into view.
-
Push the LSK adjacent to CALL-UP PARM ALPHA > indication.
- The AIDS PARAM ALPHA CALL-UP page comes into view.
- Enter the correct Alpha Call-up Code with the alphanumeric keys (Ref. AMM 31-36-00-001). See at the Parameter Alpha Call-up List (Ref. AMM 31-37-00-001).
- The Parameter Alpha Call-up shows on the bottom of the display (scratchpad).
- Push the LSK 1L, 3L, 4L or 5L Key to take over the Parameter Alpha Call-up.
- The Parameter Alpha Call-up shows on the Data Field with all information.
Parameter Call-up Menus
2
NOTE: Only the data field adjacent to the 1L key can show four values.
- Push the MCDU MENU mode key.
- The MCDU MENU page comes into view.
** ON A/C 003-050, 053-099, 101-199, 201-249, 252-299, 301-349, 351-399 POST SB 31-1148 for A/C 101-199, 253-299
Subtask 31-36-00-740-056-A A. Enter the Parameter Label Call-Up through MCDU.
ACTION RESULT
On the MCDU: On the MCDU display:
- Push the MCDU MENU mode key.
- The MCDU MENU page shows. -
Push the Line Select Key (LSK) adjacent to the < AIDS indication.
- The AIDS page shows.
- Push the LSK adjacent to the < PARAMETER CALL UP LABEL indication.
- The AIDS:LABEL CALL-UP CTRL page shows.
-
Push the LSK adjacent to the < LABEL MENU DISPLAY indication.
-
The AIDS:LABEL CALL-UP page shows.
- Enter the Parameter Label Call-Up with the alphanumeric keys in the format as follows: EQ/SYS/LAB/SDI and optional /DATABITS (Ref. AMM 31-37-00-001).
- The Parameter Label Call-Up shows on the bottom of the display (scratchpad).
NOTE: It is important to enter the DATABITS value if it is other than the default. The decimal value calculation is based on its value.
-
Push the LSK 1L or 4L to take over the Parameter Label Call-Up.
- The Parameter Label Call-Up shows on the Data Field with all information.
NOTE:Two Label Call-Up parameters can be displayed at one time.
- Push the MCDU MENU mode key.
- The MCDU MENU page shows. Subtask 31-36-00-740-057-A
B. Parameter Alpha Call-up through the MCDU.
ACTION RESULT
On the MCDU: On the MCDU display:
- Push the MCDU MENU mode key.
- The MCDU MENU page shows. -
Push the Line Select Key (LSK) adjacent to the < AIDS indication.
- The AIDS page shows.
- Push the LSK adjacent to the < PARAMETER CALL UP ALPHA indication.
-
The AIDS:ALPHA CALL-UP CTRL page shows.
- Push the LSK adjacent to the < ALPHA MENU DISPLAY indication.
- The AIDS:ALPHA CALL-UP page shows.
- Enter the correct Alpha Call-Up Code with the alphanumeric keys (Ref. AMM 31-36-00-001).
- The Parameter Alpha Call-Up shows on the bottom of the display (scratchpad).
Parameter Call-up Menus
3
Refer to the Parameter Alpha Call-Up List (Ref. AMM 31-37-00-001).
- Push the line key 2L, 3L, 4L or 5L Key to take over the Parameter Alpha Call-Up.
- The Parameter Alpha Call-Up shows on the Data Field with all information.
- Push the MCDU MENU mode key.
- The MCDU MENU page shows.