20
IP ADDRESS Tool for Ethernet co Scalable PLC AC500 © ABB Group – Version 2.0 (2009-02) Technical Guides onfiguration

AC500 Ethernet IP Config

Embed Size (px)

DESCRIPTION

AC500 Ethernet Ip Cat

Citation preview

Page 1: AC500 Ethernet IP Config

IP ADDRESS Tool for Ethernet configuration

Scalable PLC AC500

© ABB Group – Version 2.0 (2009-02)Technical Guides

Tool for Ethernet configuration

Page 2: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 2

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 3: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 3

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 4: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 4

Purpose: identification of the hardware (temporary address)

All communication modules are delivered with the same IP address.

Ethernet CommunicationSetting the ID Address

Internal:

Set the addressvia CPU keypad

Switch OFF / ONpower supply

External:

Set the address by rotary

switches

Internal:

Set the addressvia CPU keypad

Switch OFF / ONpower supply

External:

Set the address by rotary

switches

Purpose: identification of the hardware (temporary address)

All communication modules are delivered

Page 5: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 5

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 6: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 6

ID: address selected for identification

1. For verification of IP address of device connected use the menu “Tools”\”IP config tool”.

2. Click at “Scan” for have CPUs IP address

Ethernet CommunicationSetting the IP Config tool (1)

ID: address selected for identification

Network subscribers list with all recognized addresses

2. Click at “Scan” for have CPUs IP address

Page 7: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 7

1. Click on the subscriber to configure

3. Configure “IP Address”

6. “Send Configuration” IP address is fixe if in project you haven’t create IP configuration if not the address is temporary

2. Select “DHCP” for get an address automatically delivered by the server or not

Ethernet CommunicationSetting the IP Config tool (2)

4. Configure “Subnet mask”

5. Configure “Standard gateway”6. “Send Configuration” IP address is fixe if in project you

haven’t create IP configuration if not the address is temporary

Page 8: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 8

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 9: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 9

Ethernet CommunicationPM5xx-ETH and CM577-ETH (1)

Parameterisation for Ethernet CPU port

Parameterisation for Ethernet Coupler port Slot1 per example

ETH (1)

Page 10: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 10

Ethernet CommunicationPM5xx-ETH and CM577-ETH (2)

1. IP manage per user

2. Select “DHCP” for get an address automatically delivered by the

server or not per user

3. Configure “IP Address”

4. Configure “Subnet mask”

5. Configure “Standard gateway”

ETH (2)

Page 11: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 11

Ethernet CommunicationPM5xx-ETH and CM577-ETH (3)

ABB NetConnfig Protocol active

SNTP protocol is active.

Enable SNTP client mode

Enable SNTP server mode

ETH (3)

Web server active

Page 12: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 12

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 13: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 13

Ethernet CommunicationSetting the IP Address

Configuration IP address with N sub mask 255.255.0.0 , G gateway 0.0.0.0 .

Validation by OK went it’s finish .

Run

Ip-set

slot00

Static

A1 010

A2 033

A3 071

A4 001

CFG

CFG

CFG

CFGOK

OK

CFG

OK

Configuration IP address with keypad A for IP address 10.33.71.1 N sub mask 255.255.0.0 , G gateway 0.0.0.0 .

Validation by OK went it’s finish .

N1 255

N2 255

N3 000

N4 000

G1 000CFG

CFG

CFG

CFG

CFG

G2 000CFG

G3 000CFG

G4 000CFG

Page 14: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 14

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 15: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 15

Ethernet CommunicationConfiguration IP PLC browser

Change IP address with PLC browser

confdata ipcfg 0 10.33.71.174 255.255.0.0

Slot number (0…4)

IP address

Configuration IP PLC browser

Change IP address with PLC browser

confdata ipcfg 0 10.33.71.174 255.255.0.0

IP address net mask

Page 16: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 16

Ethernet ID

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Ethernet CommunicationComing up

Configuration IP Config TOOL

Configuration IP ABB Configurator

Configuration IP with keypad

Configuration IP PLC browser

Configuration IP Per program with Bloc

Page 17: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 17

Ethernet CommunicationConfiguration IP Per program with Bloc

Function Bloc for change IP address per program

Configuration IP Per program with Bloc

Function Bloc for change IP address per program

Page 18: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 18

Ethernet CommunicationConfiguration IP Per program with Bloc

Function Bloc for know IP address

Configuration IP Per program with Bloc

Function Bloc for know IP address

Page 19: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 19

1. CoDeSys Help\Target System\AC500 / S500\System Technology\System Technology of the AC500 Communication Modules\The Ethernet Communication Module

Cross-References to Documentation

The Ethernet Communication Module\

References to Documentation

Page 20: AC500 Ethernet IP Config

© ABB Group November 28, 2011 | Slide 20