2
Meets IEEE 519 harmonic limits. FILTER JDES developed this rapid prototype using a standard electrical cabinet and JDES technology. This project included electrical design to define and select the passive filter components, mechanical expertise for high power packaging and high power density water cooling, and production AC supply software inside the inverter. Liquid cooled AC Sine Wave Filter High power density AC SINE WAVE FILTER How many ways can you use 200 kW of clean 3-phase power?

AC SINE WAVE FILTER - John Deere...480V AC grid 480V AC bus-JDES Inverter LCL Filter 3-Phase Loads LCL Filter +-High Voltage Power Supply 750 V DC 480 V DC A A’ B B’ C C’ 480

  • Upload
    others

  • View
    20

  • Download
    0

Embed Size (px)

Citation preview

Meets IEEE 519 harmonic limits.

FILTER

JDES developed this rapid prototype using a standard electrical cabinet and JDES technology. This project included electrical design to define and select the passive filter components, mechanical expertise for high power packaging and high power density water cooling, and production AC supply software inside the inverter.

Liquid cooled AC Sine Wave Filter

High power density

AC SINE WAVE FILTERHow many ways can you use 200 kW of clean 3-phase power?

Example of filter used for grid tie

JDESInverter

+350A720 V DC

350A

480V AC grid

480V AC bus

-

JDESInverter LCL Filter

3-Phase Loads

LCL Filter

+

-

High Voltage Power Supply

750 V DC 480 V DC

AA’

BB’

CC’

480 V DC (rms, L-L)

Coolant (Bi-temp)

Coolant (Bi-temp)

10 lpm

30 lpm10 lpm

JDES Inverter

VoltageNominal Output 480VACOperating Voltage Range 456 to 504 VAC

EnvironmentalAmbient Temperature -40°C to 85°C

Dimensions605L x 507W x 393T mm

CurrentLine Currents 350 A RMS with 3-Φ loads

Future Possible unbalanced loads and 1-Φ loads

Fundamental FrequencyNominal 50 Hz / 60 HzPotential operating range 30-90 Hz

Switching FrequencyNominal 4 kHzPotential operating range 3-10 kHz

CoolingMaximum Inlet Coolant Temperature 70 °CMinimum Flow Rate of Coolant 10 liters per minutePossible Future 50°C coolant available

AC SINE WAVE FILTER Specifications

The filter is intended to meet IEEE 519 harmonic limits through the PD400 operating envelope. An unloaded system will produce a 3.31% THD

The filter is to be 50% - 50% Water/ethylene glycol cooled and operate in a 70 °C maximum temperature environment.