AC - 10
WARNINGBuyer/User assumes all responsability for safety and properuse not in accordance with the directions and sately labels.
• Built-inwaterpump• Built-inbleedvalve• Useinsumporhangingpump• Bubblecounterincluded• Easytwistofftop• For10to75galaquarium
FEATURESViaAqua®Acro-CalTMCalciumReactoroffersasimpleandconvenientsolutionformaintainingcalciumandalkalinityinyourreeftank.Aftertheinitialsetup,thecalciumreactorrequiresminimalmaintenance.Acalciumreactorisalmostanecessityfortanksheavilystockedwithstonycoral,wherecalciumandalkalinitydemandsarehighandwillpromotecorallinealgaegrowth.Acro-CalTMCalciumReactorprovidesasteadysupplyofcalciumbyusingCO2todissolvemediainthereactorand,thus,releasingcalciumintoyourwater.TheeffluentreleasedalsoactsasabuffertostabilizekH.
WARNING AND SAFEGUARDWARNING
» This product may contain chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Wash you hand after handling the product.
» It is your sole responsability to verify that the plug and receptacle are clean/free of moisture and salt build up at all times. The receptacle must be free of water, salt, calcium, and magnesium. Failure to do so may cause fire and/or loss of life.
» Do not plug into an extension cord or power strip.
» A drip loop must be used when plug into any electrical devices. A drip loop is part of the cord hanging below the receptacle.
» The national code requires all aquarium equipment to be plugged into a G.F.C.I. (Ground Fault Circuit Interrupter) electrical outlet. If you do not have a G.F.C.I., have an electrician install one prior to operating any aquarium components.
• ReadandfollowallinstructionsbeforeusingtheAcro-CalTMReactortoensureproperuseandapplication.
• Usethisproductforitsintendeduseonly.• DonotoperateAcro-CalTMReactorwithoutwater.Doingsocancausepermanentdamagetothepump.
• Youmustverifythatthereceptacleiscleanandfreeofwater,moisture,andsaltbuildupatalltimes.Failuretodosomaycauseelectricalarchingresultinginfireorelectricalshock.
• Priortomaintenanceonanyelectricalaquariumapplianceoraquarium,youmustdisconnectallelectricalaquariumdevices.
• RoutinemaintenanceisrequiredtoensurethemaximumperformanceandthelongevityoftheAcro-CalTMReactor.Seemaintenanceguidelines.
• Theuseofasurgesuppressorisstronglyrecommended.
maxmin
minmaxmin
Drip loop
DripLoop
GFCIONLY
1
ItemsRequiredforInstallation(notincluded):• CO2Source• CO2Regulator• CO2CheckValve• SiliconeTubing• Oceanpure™CalciumReactorMedia• pHController(recommended)
maxmin
minmaxmin
4. Hanger
7.Stand pipe
9. Base
8. Suction cup bracket
5. Support grid
6. Sponge
6” Media(not included)
10. Bubble counter
1. Green water intake valve
3. Blue effluent water valve
2. White air-vent-bleed valve
maxm
in
maxm
in
maxm
in
Green water intake valveBlue effluent water valveWhite air-vent-bleed valve
2
PART LIST
1. Greenwaterintakevalve2. Whiteair-vent-bleedvalve3. Blueeffluentwatervalve4. Hanger5. Supportgrid6. Sponge7. Standpipe8. Suctioncupbracket9. Base10. Bubblecounter
INSTALLATION:
1.Removethetopofthecalciumreactor.Rinsecalciumreactormedia.Placeaspongeoverthebottomsupportgrid.Addapproximately6”ofmediatothereactor.Whenaddingmediaverifythatmediadoesnotgodownthestandpipe.Placeanotherspongeoverthetopsupportgripabovethemedia.Screwlidbackontothecalciumreactorandverifythattheoutputisconnectedtothestandpipe.
2.Chooseoneofthefollowingwatersource(in):a)Gravity(unitinstalledbelowaquarium):Connectapieceofsiliconetubingtothegreenwaterintakevalve,insertthelineinsidetheaquarium2”belowthewatersurface.Thetubecanbesecureddirectlytotheoverflowboxusingaziptie.
b)Pressure:Chooseanexistingpressureline.Cutthelineandplumbinatee.Thebleedlinewillsupplywatertothecalciumreactor.Thebleedlinemusthaveavalveandreducedto3/16”barb.Withthevalveclosedconnectsthesiliconetubingfromthebleedlinedirectlytothegreenwaterintakevalve.
c)Supplypump:Useaseparatelowflowpump.Reducetheoutputofthepumpto3/16”barb.Connectsiliconetubingdirectlytothegreenwaterintakevalve.Dependingonthesizeofthepump,ableedlineisneededtokeepwaterflowingthroughthepumpatalltimes.
3.Effluentwater(out):Connectsiliconetubingtotheblueeffluentwatervalve.Securethelinetothebackoftheaquariumorsump.Thesiliconetubingmustbepositionedabovewaterlevelsothatyoucanseedropletsofwaterflowingfromthetube.
4.Fillbubblecounterthreequartersfullwithfreshwater.
5.CO2/Waterintake(in):AttachthesiliconetubingfromtheCO2regulatortoacheckvalvetothebubblecounterandtotheCO2greenwaterintakevalve.Seediagrambelow.
6.Air-vent-bleed:Attachsiliconetubingtothewhiteair-vent-bleedvalve.Securesiliconetubingtotheaquariumorsump.ThishelppreventsairandCO2frombuildingupatthetopofthecalciumreactor.
7.PrimingCalciumReactor:a)Gravity:Openthegreenwaterintakevalve.Disconnectthetubingfromthegreenwaterintakevalve,applysuctiontostartasiphonandreattachitbacktothegreenwaterintakevalve.Keepthewhiteair-vent-bleedvalveopenuntilthecalciumreactorisfullofwater.
b)Pressure:Openthegreenwaterintakevalve,thenthewhiteair-vent-bleedvalve(thisvalvemaynothavetobeopenedalltheway).Whenastrongpumpisused,thewhiteair-vent-bleedvalveonlyneedstobeopenaquarterturn.Closethewhiteair-vent-bleedvalvecompletelywhenthecalciumreactorisfullofwater.
c)Supplypump:Openthegreenwaterintakevalve.PlugthepumpintoaGFCIoutlet.Openthewhiteair-vent-bleedvalveuntilthecalciumreactorisfullofwater.
maxmin
minmaxmin
BubbleCounter
Check Valve CO2 (in)
CO2Tank
CO2 Regulator
3
8.Oncethecalciumreactorisprimed,closewhiteair-vent-bleedvalve.Ifairisaccumulatedinthecalciumreactor,openwhiteair-vent-bleedvalveandleavethegreenwaterintakevalveopen.
9.Turnonthepumpandwaituntilthewaterclears.Opentheblueeffluentwatervalve.Adjustthevalvesothereisabrokenstreamofwaterdischargingfromthetube.Setthevalveasslowaspossiblewithoutbeingabletocountanydroplets.
10. TurnontheCO2controlvalve.AdjusttheCO2regulatortoproduce60bubblespermin.inthebubblecounterchamber.TheCO2inputisdirectlyrelatedtowaterflowrate:
• ToraisepHineffluentwaterincreasewaterflowordecreaseCO2• TolowerpHineffluentwaterdecreasewaterfloworincreaseCO211. ApHmeter/controllerisrecommendedtomaintainaproperlevelofpHintheaquarium.CollectasmallamountofeffluentwaterandtestitwithapHmeter.InitiallyadjusttheCO2atpH7.5.MonitorthepHintheaquariumandverifythatit’snotdroppingfast.IfpHdropsrapidly,decreaseCO2immediately.Atalltimes,thepHoftheaquariumshouldbeover8.0.TheidealpHoftheeffluentwatershouldbe6.5to7.5.IttakesapproximatelytwoweekstostabilizethepHoftheeffluentwatertotheideallevel.ContinueincreasingordecreasingtheCO2oreffluentwateramountasneededtoachieveoptimumpHlevel.
12. After24hours,measurethecarbonatehardnessoftheeffluentwater.Thehardnesslevelshouldbearound12-16dKH.Calciumlevelswillincreasebuttherateitincreasesdependonthetypeofmediaused.OceanpureTMCalciumReactorMediaisrecommended.
13. ContinueaddingthecalciummediauntiltheCalciumReactorstartstowork.
maxmin
minmaxmin
maxm
in
maxm
in
maxm
in
CO2Tank
2”
Top view of calcium reactor
BubbleCounter
Drip Loop
Check Valve
CO2 Regulator
Aquarium or Sump
Air-vent
H2 O
(out)
H2O (in)
CO2 (in)
CO2 (in) H2O (in)
H2O (out)
Air-vent
4
SETUP DIAGRAM
A) GRAVITYGreenWaterIntakeValve:CO2/H2OIn
BlueEffluentWaterValve:H2OOut
Air-Vent-BleedValve
maxmin
minmaxmin
BubbleCounter
Drip Loop
Pump
Check Valve
Aquarium or Sump
Air-vent
H2 O
(out)
H2 O
(in)
CO2 (in)
CO2Tank
CO2 Regulator
maxmin
minmaxmin
Valve
BubbleCounter
Drip Loop
Check Valve
Aquarium or Sump
Main PumpLine
Air-vent
H2 O
(out)
H2O (in)
CO2 (in) PVC Pipe
CO2Tank
CO2 Regulator
5
C) SUPPLY PUMP
B) PRESSURE
MAINTENANCE
1.RoutinemanteinanceisrequiredtoensurethemaximumperformanceandthelongevityoftheViaAqua®Acro-CalTMCalciumReactor.
2.ForproperoperationoftheCalciumReactor,cleantheimpelleronceamonth.a)Removethetopofthecalciumreactor.b)Removetheimpellercover.c)Removetheimpellerandshaft.Withasmallbrushcleantheinsideoftheimpellerandimpellercover.
d)Iftheimpellerdoesnotspineasilyontheshaft,soaktheunitwith3:1vinegarsolution.Removeallcalciumresiduebetweentheshaftandrotor.
e)Reassemble.3.Replacecalciummediaevery3to6monthsdependingontheusage.4.CleantheViaAqua®Acro-CalTMCalciumReactorevery3to6monthsalongwiththewaterpump.
5.Makesureallpartsarefreeofdebrisandcalciumbuild-up.
PH CONTROLLER (RECOMMENDED)
ThepHControllerisusedtokeeptheeffluentwateratapresetlevel.Itemsneeded:• pHcontroller• CO2regulatorwithsolenoid• Containerfortheeffluentwater(mustfitpHprobe)Installation:• SecurethecontainertothepHprobe.• PlugtheelectronicsolenoidintothepHcontroller.• FollowpHcontrollermanufactureinstructionsforproperunitsetting.
IfyoustillhavequestionsabouthowtoinstallormaintaintheAcro-CalTMReactor,consultyourlocalfishstore.Continuemonitoringthewaterquality(calcium,alkalinity,effluentpH)toensureaproperlyworkingCalciumReactor.
6
Replacement Parts UPC 0069037
Motorhousing 29185
Replacementsponge-2pack 29222
Impeller 29239
Bubblecounter 29345
Oceanpure™CalciumReactorMedia TBA
LIMITED WARRANTY
CommodityAxis,Inc.®warrantsthattheViaAqua®Acro-CalTMCalciumReactorisfreefromdefects foraperiodofoneyear fromthe initialdateofpurchaseshownon theoriginalcashregister receipt. Commodity Axis, Inc.® disclaim all other warranties, express or implied,including but not limited to any implied warranties of merchantability and/or fitness for aparticular purpose.Although this limited warranty gives you specific rights, you may haveotherrightswhichvaryfromstatetostate.Thiswarrantyisvoidifthefailureisduetomisuse,tampering,negligence,abuse,accidentand/orsubmersion,afailuretoproperlyinstall,maintain,clean, prefilter, reassemble, and/or use the ViaAqua®Acro-CalTM Calcium Reactor with aGroundFaultCircuitInterrupter(G.F.C.I.).
CONSUMER REMEDIES
CommodityAxis, Inc.’s entire liability and your sole and exclusive remedy shall be eitherrepair or replacement of theViaAqua®Acro-CalTM CalciumReactor only if you return thedefectiveunitdirectly toCommodityAxis, Inc.®with theoriginal receipt in itsoriginalboxalongwithfifteendollars($15.00)forshippingandhandling.DonotsendtheViaAqua®Acro-CalTMCalciumReactorbyinsuredmail.YoumaysendyourreturnsorreplacementsbyUPSif requiring a signature upon arrival.Any replaced unitwill bewarranted for the remainingtimeoftheoriginalwarrantyperiod.Innoeventshallanyshippingchargesbereimbursed.InnoeventwillCommodityAxis, Inc.®be liable foranyconsequentialor incidentaldamages,includingbutnotlimitedtolostsealife,personalinjury,propertydamage,damageequipment,lostprofits,lostwages,lostsavings,lostincome,etc.,arisingoutoftheuseoftheViaAqua®Acro-CalTMCalciumReactor.Somestatesdonotallowforthelimitationorexclusionofliabilityforincidentalorconsequentialdamages,sotheaboveexclusionmaynotapplytoyou.
7
Please fill out this warranty card and mail it with PROOF OF Purchase within 15 days of purchase to: Commodity Axis Inc.,300 South Lewis Rd. Unit J. Camarillo CA 93012, USA Name Date
Product Name Mode No
Address
City State Zip Code
Country Home Phone
Cell Phone Email
Date of Purchase Seller (Retail Name)
Seller’s Location Phone
IMPORTANT: Please make a copy of this warranty card and retain it for your records. Warranty policy is subject to change without notice.
REGISTRATION CARDONE (1) YEAR WARRANTY CARD
Bringing Products to Life300 South Lewis Rd. Unit J. Camarillo CA 93012
Fax: (888) 989 0878www.ViaAquaOceanpure.com