5
RENTON’S PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH NSW 2380 PROPERTY INSPECTION REPORT NO. 7377 DATE OF INSPECTION: 6 th August 2018 REPORT TO: NAME: Drew Evans ADDRESS: 16 Anzac Parade, TORONTO NSW 2283. DETAILS OF INSPECTED PREMISES: Single level residence (photo 1), radiata pine structural timbers, concrete floor and foundation, brick exterior, tile roof, double car garage included in home and alfresco area. This inspection report is issued in the knowledge that Rentons Pest Control Services Pty. Ltd. Is engaged only to advise on the presence of Termites or Borers at the time of inspection and also will not be held responsible for any activity which may exist in any section of the premises where it has been unable to inspect, providing such inability to inspect has been made known in this report. AREAS INSPECTED AND REPORTED ON PEST ACTIVITY Foundation Area – Concrete floor and foundation. No termite or borer activity located at inspection of exterior walls. Joists and Bearers – Concrete floor and foundation. Floor – No termite or borer activity located at time of inspection. Exterior Walls – No termite or borer activity located at inspection of exterior walls, door and window surrounds. Home has been constructed with an exposed concrete slab base and should have a minimum slab edge of 75mm. Concrete path covers exposed edge in several places, giving termites a hidden entry point to cavity wall. Note – It appears a termite barrier has been installed between concrete path and home (photos 2 & 3). Note – No termite management notice was located at time of inspection. Interior and Fittings – No termite or borer activity located at time of inspection. Thermal imaging camera and moisture meter used during inspection. Roof and Ceiling Timbers – No termite or borer activity located at the time of inspection. Note – Roof void is insulated (photo 4).

ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

RENTON’SPEST CONTROL SERVICES P/L

ABN 61 069 238 035

Certificate No. 7377

ADDRESSOFINSPECTEDPREMISES:- 2/9 Silversmith Place, GUNNEDAH NSW 2380

PROPERTYINSPECTIONREPORTNO.7377DATE OF INSPECTION: 6th August 2018

REPORT TO:

NAME: Drew Evans

ADDRESS: 16 Anzac Parade, TORONTO NSW 2283.

DETAILS OF INSPECTED PREMISES: Single level residence (photo 1), radiata pine

structural timbers, concrete floor and foundation, brick exterior, tile roof, double car garage

included in home and alfresco area.

ThisinspectionreportisissuedintheknowledgethatRentonsPestControlServicesPty.Ltd.IsengagedonlytoadviseonthepresenceofTermitesorBorersatthetimeofinspectionandalsowillnotbeheldresponsibleforanyactivitywhichmayexistinanysectionofthepremiseswhereithasbeenunabletoinspect,providingsuchinabilitytoinspecthasbeenmadeknowninthisreport.

AREAS INSPECTED AND REPORTED ON PEST ACTIVITY

Foundation Area – Concrete floor and foundation. No termite or borer activity

located at inspection of exterior walls. Joists and Bearers – Concrete floor and foundation. Floor – No termite or borer activity located at time of inspection. Exterior Walls – No termite or borer activity located at inspection of exterior

walls, door and window surrounds. Home has been constructed with an exposed concrete slab base and should have a minimum slab edge of 75mm. Concrete path covers exposed edge in several places, giving termites a hidden entry point to cavity wall. Note – It appears a termite barrier has been installed between concrete path and home (photos 2 & 3). Note – No termite management notice was located at time of inspection.

Interior and Fittings – No termite or borer activity located at time of inspection.

Thermal imaging camera and moisture meter used during inspection.

Roof and Ceiling Timbers – No termite or borer activity located at the time of inspection.

Note – Roof void is insulated (photo 4).

Page 2: ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

RENTON’SPEST CONTROL SERVICES P/L

ABN 61 069 238 035

Certificate No. 7377

PROPERTYINSPECTIONREPORTNO.7377

Other Structures - Nil. Fences and yard area- No termite or borer activity located at time of inspection. Areas Not Accessible to Visual Inspection – Enclosed wall timbers (This report is based on the evidence visible at the time of

inspection.)

RECOMMENDATIONS – We recommend that as home has been constructed with an exposed concrete slab base to allow termite activity to be detected it must have a minimum slab edge of 75mm at all times. Information on installation dates and of termite systems should be sought from the current owners or builders on termite system around home. An annual termite and borer inspection be carried out on property.

Photo 1 – Front view of residence. Accredited Inspector – Jon Renton

License No. – 5069665

Page 3: ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

RENTON’SPEST CONTROL SERVICES P/L

ABN 61 069 238 035

Certificate No. 7377

Photo 2 – It appears a termite barrier has been installed between slab edge and concrete path at side of home.

Photo 3 – It appears a termite barrier has been installed between slab edge and concrete floor of alfresco area.

Page 4: ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

RENTON’SPEST CONTROL SERVICES P/L

ABN 61 069 238 035

Certificate No. 7377

Photo 4 – Roof void is insulated.

Photo 5 – Termite protection notice located in meter box.

Page 5: ABN 61 069 238 035 PEST CONTROL SERVICES P/L€¦ · PEST CONTROL SERVICES P/L ABN 61 069 238 035 Certificate No. 7377 ADDRESS OF INSPECTED PREMISES: - 2/9 Silversmith Place, GUNNEDAH

RENTON’SPEST CONTROL SERVICES P/L

ABN 61 069 238 035

Certificate No. 7377

Photo 6 – 75mm concrete exposed edge at side of home.

Photo 7 – Rear view of residence.