DESCRIPTION
ABCD New DAQ System. Hucheng Chen Brookhaven National Lab. SCTDAQ System. ABCD New DAQ System. Power Supply. PXI. LabVIEW. Plots. NI HSDIO. RAW DATA (BIN FILE). Schematics of Test Setup @ BNL. PC. INSTEK PST-3201 3.3V, 4.0V, 3.5V. GPIB-USB-HS. RAW DATA (BIN FILE). PXI-1036 - PowerPoint PPT Presentation
Citation preview
2006-09-19 1
ABCD New DAQ System
Hucheng Chen
Brookhaven National Lab
2006-09-19 2
SCTDAQ System
2006-09-19 3
2006-09-19 4
ABCD New DAQ System
PXI
NI HSDIOLabVIEW
RAW DATA(BIN FILE)
Power Supply
Plots
2006-09-19 5
2006-09-19 6
Custom Design
PC
Schematics of Test Setup @ BNL
PXI-1036PXI Chassis
PXI-6561NI HSDIO
LabVIEW
RAW DATA(BIN FILE)
INSTEKPST-3201
3.3V, 4.0V, 3.5V
PlotsPXI-8360MXI-Express
PCIe-8361MXI-Express
GPIB-USB-HS
ABCDInterface
ABCDTest Board
2006-09-19 7
2006-09-19 8
Comparison
• SCTDAQ– More VME Modules
• MuSTARD
• SLOG
• Patch Card
• SCT LV-3
• SCT HV
• (CLOAC)
• PCI MXI-2 VME Interface
– Complex Development Environment• Microsoft VC++
• ROOT
• Hard to be ported to different hardware platform (rewrite VME interface library)
• ABCD New DAQ– Few PXI Module
• NI HSDIO
• MXI-Express PXI Interface
– Simple Development Environment• NI LabVIEW
• Easy to be ported to different HSDIO module (NI maintains a single NI-HSDIO library)
2006-09-19 9
2006-09-19 10
2006-09-19 11
Work Plan
• Done– System Setup– Simple Test
• ABCD is functioning– Digital Test
• HardReset• PipelineTest
– Analog Test• StrobeDelay
• To Be Done– Analog Test – Data Analysis