ABBREVIATED ENGINEER’S REPORT
ROAD PROJECT
I94, Drainage System Rehabilitation From the Toll Road (East) to 0.43 miles East of SR49
RP 15+70 to RP 26+05
PROJECT NUMBER: 1592882
CONTRACT: ‐‐
Prepared by LaPorte District Technical Services Division October, 2019
www.in.gov/dot/ An Equal Opportunity Employer
LaPorte District 315 E. Boyd Boulevard LaPorte, Indiana, 46352
PHONE: (855) 464-6368 Eric Holcomb, Governor Joe McGuinness, Commissioner
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 1 of 6
ABBREVIATED ENGINEER’S REPORT
PROJECT NUMBER: 1592882
ROUTE IDENTIFICATION AND FEATURE CROSSED: I94 from Toll Road (East) to 0.43 miles East of SR49
PROJECT LOCATION: Lake Station Township, Lake County, Sec 9, Twp 36 N, Range 7 W; Portage
Township, Porter County, Sections 1, 2, 3 & 10, Twp 36 N, Range 7 W, Sections 5, 6, 25, 26, 32, 33, 34, 35, Twp 36 N, Range 6 W; Section 30, Twp 37 N, Range 5 W
REFERENCE POST: RP 15+70 to RP 26+05
Purpose of Report The purpose of this report is to document the engineering assessment phase of project development, including all coordination that has been completed in preparation for this bridge project. This document outlines the proposal and is intended to serve as a guide for subsequent survey, design, environmental, right of way and other project activities leading to construction. The preferred alternative identified in this document is considered predecisional, pending the outcome of environmental studies.
Project Location This project is located on I94, from a point 0.1 mile west of I80/90 (Toll Road) to a point 0.43 mile east of SR49 in Porter County. The project is in the Indiana Department of Transportation’s LaPorte District, Gary Sub‐District. This location is in a rural planning organization region, the Northern Indiana Regional Planning Commission (NIRPC).
Project Need and Purpose The need of this project is based on the existing condition of the storm water management system for the I94 corridor. Based on existing condition data, all of the small culverts are in less than fair condition, with all pipes showing rust and corrosion, mainly a result of the use of chlorides during winter operations. The median drainage is managed by inlets along the concrete median barrier, connected with small section of corrugated metal pipe, which are all in poor condition. The cross culverts under I94 are all rated in poor condition and there have been three sink holes reported in this section of I94 due to the poor condition of pipes under the mainline pavement and median. The purpose of this project is to rehabilitate the storm water management system for the I94 corridor, improving the overall condition of pipe culverts and inlets to good or better.
Existing Facilities The existing roadway facility is classified as an Interstate and is part of the 3R roadway network and is part of the US National Highway System (NHS). The roadway is on the National Truck Network. The posted speed limit at the project location is 70 mph. Roadway The existing roadway is 36’ per bound through the project limits. The existing roadway consists of 12‐foot travel lanes and 17’ median / 10’ outside paved and useable shoulders. The existing shoulder
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 2 of 6
widths are acceptable. The roadway embankment side slopes at the structure are in good to fair condition. Road History
I94 Pavement History Within Project Limits
Year Width Type of Work
1969 36’/bound Cont Reinf Conc Pavt
1992 Road Rehabilitation (3R/4R) (R‐19620)
2008 HMA Overlay, Minor Structural (R‐28234)
2016 HMA Overlay, Minor Structural (1172295 / R‐34353)
2017 HMA Overlay, Minor Structural (1172251 / R‐33950)
Drainage Existing drainage through the project is primarily through sheet flow away from the road into ditch lines on the outside of the pavement, or sheet flow to the interstate median. The storm water management system was established to convey runoff from the median to the outside side ditch lines, or to propagate flow under I94 to larger ditch lines or streams. All of the cross‐pipe small culverts and large culverts were constructed in 1969 and were not replaced or rehabilitated in 1992 when the pavement was replaced, and the median was enclosed. The current median drainage appurtenances (H5 and X5 inlets with outlet pipes) were constructed in 1992 and have not been rehabilitated since that project. This section of I94 had the drainage appurtenances inspected in 2017/2018 with condition ratings no better than fair (5). The majority of the pipe culverts were rated as poor (3), requiring rehabilitation. There is a total of 182 storm water management structures of some type (pipe culvert, H5 inlet or X5 inlet) within the project limits. Of these structures, there are 27 pipe culverts that are considered cross pipes (connect one outside side ditch to the other outside side ditch, rough length ±210’). The median drainage consists of 133 H5 inlets (66 pairs where the H5 inlets on either side of the concrete median barrier are connected in series), and 16 X5 inlets. There are 31 sets of H5 inlet pairs that have outlet pipes that carry runoff under the mainline pavement and shoulders to drain into an outside side ditch line. There are no storm sewer pipes directly under the concrete median barrier between the POB and mile post 19 within the project limits. Eighteen H5 inlet pairs are connected to each other or a cross pipe culvert with longitudinal storm sewer pipe (mostly CMP) running directly under the concrete median barrier between mile post 19 and the POE. Railroads I94 crosses CSX tracks at RP 16+65. No insurance is anticipated for this project as all work should be at least 50’ from the tracks. The crossing is not at grade.
Traffic & Crash Information Traffic Data The table below shows the data provided.
TRAFFIC DATA
Year AADT (VPD) DHV TRUCK AADT
2018 87,569 7,150 17,827
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 3 of 6
Crash Data & Analysis Crash data was not reviewed as part of this assessment as crash analysis does not impact the purpose or support the need of the project.
Alternatives and Recommendations Alternate A: Do Nothing This alternate would allow the existing drainage appurtenances to remain in place with no improvements. This alternative will result in continued deterioration of the culverts, and significantly increase the risk of significant failure of a pipe culvert under the I94 mainline pavement, thus impacting public safety of an interstate corridor. This alternative does not meet the need nor achieve the purpose of the project and will not be considered further. Alternate B: Rehabilitate the existing storm water management system This alternative meets the need and purpose of the project and is the preferred alternative. Details of Preferred Alternate Rehabilitation of the existing drainage system though the length of the project involved addressing the following items:
1. Existing H5 inlet pairs with pipes under the concrete median barrier; pipe is deteriorating and cannot be adequately maintained due to the H5 inlet structure dimension.
2. Pipe culverts crossing under I94 in poor condition 3. Existing storm sewer pipes running under the median shoulder of I94 that are in poor condition 4. Connection of longitudinal storm sewer pipes to cross pipe culverts and the condition of said
connection. H5 Inlet pairs: All H5 inlet pairs will be removed and replaced. This is required to eliminate existing poor condition pipes under the concrete median barrier. These paired inlets will be replaced with a Florida DOT (FDOT) standard median inlet (see appendix for standard plan) that eliminates the pipe under the concrete median barrier. Cross Pipe Culverts: All cross‐pipe culverts shall be lined with CIPP. Cross pipes originating from the median (i.e. from an H5 inlet pair) shall be lined with CIPP after replacement of the upstream H5 inlet pair. Note no pipe lining shall be done prior to replacement of existing longitudinal storm sewer pipe connections. Existing Storm Sewer Pipes: Buried pipes running longitudinally within the median that are not directly under the concrete median barrier shall be removed and replaced in kind. Buried pipes running longitudinally with the direction of traffic under concrete median barrier are to be abandoned in place (see USP within this document). This system shall be replaced with new longitudinal storm sewer pipes running under the median shoulder using the same pipe size as provided under the concrete median barrier. Due to the nature of the corridor, no CMP is allowed for Type 1 pipe material in this corridor. Existing Pipe Connections: There are two types of longitudinal pipe connections existing within the project limits.
a. Inlet to inlet connection. This shall be perpetuated due to replacement of the upstream and downstream inlets as well as replacement of the longitudinal storm sewer pipe.
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 4 of 6
b. Storm sewer pipe to cross culvert connection: These connections occur primarily with cross pipe culverts with a top size of 36” diameter. These connections shall be replaced with a Manhole, Type J or Type K to facilitate a positive, engineered connection that allows future maintenance access to the storm sewer system.
All pipe trenches shall utilize Flowable Backfill, Removable to facilitate accelerated construction techniques. Designer shall video inspect existing pipes to determine the extent of any section loss for each pipe. Note that significant clean‐out of existing pipes may be required to facilitate accurate video inspection of the pipes within the project limits. The current recommendation may be revised in design once the actual section loss for each pipe is determined. Replacement of pipes crossing under I94 to side ditches is a possibility, and if required, will entail a scope change and review by District staff. Pavement design and a geotechnical investigation will be needed for this project to ensure that the PCCP Patching required for the median shoulder is appropriate. This drainage system rehabilitation is proposed to take place in construction year 2024
Cost Estimate The cost of the preferred alternative is as follows:
Estimated Total Project Costs Amount Comments Right of Way Purchase Right of Way Services Preliminary Engineering $250,000.00 Railroad PE $50,000.00 Railroad CN 0.00 No RR impacts anticipated Utilities PE (UT1) $100,000.00 Utilities CE (UT2) 0.00 No utility relocations anticipated Construction Total: $10,740,000.00 Construction Engineering (CE) $200,000.00 Other Considerations TOTAL: $11,340,000.00
This estimate includes removal and replacement of the existing shoulder pavement where needed, removal and replacement of the existing concrete median barrier where needed, fabrication and installation of the precast median inlets, removal and replacement of the existing longitudinal storm sewer pipe, and lining of the cross pipes using CIPP liner.
Environmental Issues This project will likely require preparation of a CE Level 2. The District or the District’s consultant will prepare an environmental document in accordance with the National Environmental Policy Act, National Historic Preservation Act, and other relevant laws. Because of anticipated work in the channel, a waterway permit will likely be needed. A final permits determination will be made during design.
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 5 of 6
No publicly owned parks, recreational areas or historic sites considered as Section 4(f) properties were identified within the project limits. A Section 4(f) analysis will not be necessary as part of the environmental documentation prepared for the project. A waters report and wetland delineation map will be required, as the I94 drainage system includes many low grade wetlands within the overall interstate corridor. A Rule 5 erosion control permit will be needed if 1 acre or more of ground is disturbed. Best management practices will be incorporated into the plans and constructed regardless of whether a Rule 5 permit is needed. Potential historic properties listed on or eligible for the National Register of Historic Places and the Indiana Register of Historic Sites and Structures are not known to be located within the project vicinity.
Right‐of‐Way Impact This project is not expected to require the purchase of right of way
Utilities There are no buried utilities within the I94 median or under I94 through the project limits. No utility conflicts are anticipated or expected.
Traffic Maintenance During Construction This project is considered a mobility significant project per IDM Chapter 81, and will require the development of a Transportation Management Plan (TMP). Due to the nature of the project, this work may be done under traffic with no lane closures. Traffic may be shifted up to one half lane width (six feet) away from the median, and the work zone protected by temporary concrete barrier (TCB). The work zone speed limit may only be reduced to 60 mph with the use of TCB; no further reduction of speed limit on I94 is required.
Other Projects There are no other projects currently programmed near/within the project limits.
Project Description: Storm Sewer Repair or Replacement
Des #: 1592882 Page 6 of 6
This document was prepared by:
Paul South, PE Scoping Manager, LaPorte District
Reviewed by:
Chris Vergon, PE District Culvert Engineer, LaPorte District
Reviewed by:
//Omitted//
Paul South, PE Scoping Manager, LaPorte District
Approved by:
Steve Benczik, PE System Asset Manager, LaPorte District
Appendices: Location Map Additional Project Details Base Structure Data Table Cost Estimate
Project Description:
Contract No:
Designation No:
CONTRACT NO.
PROJECT LOCATION SHOW N BY
LOCATION MAP
Porter
Storm Sewer Repair ---
---
---
RP 15+70
DES ---
BEGIN PROJECT
RP 19+00
DES ---
END PROJECT
Project Description:
Contract No:
Designation No:
CONTRACT NO.
PROJECT LOCATION SHOW N BY
LOCATION MAP
Porter
Storm Sewer Repair ---
---
---
RP 19+00
DES ---
BEGIN PROJECT
RP 26+05
DES ---
END PROJECT
12" 15" 18" 24" 36"
FLO
WAB
LE
BACK
FILL
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6)
PCCP
PA
TCH
ING
, FU
LL D
EPTH
MAN
HO
LE, J
PIPE
, TYP
E 1,
CI
RCU
LAR,
12
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
15
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
18
IN
PIPE
, REM
OVE
IN. LFT YRS LFT LFT LFT LFT LFT EACH CYS EACH LFT LFT EACH SYS EACH LFT LFT LFT CYS LFT
STRUCTURE DATASMALL CULVERT ID
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
LOCATION
SIZE
DESCRIPTION
LEN
GTH
OUTLET (2)
CON
NEC
T TO
STR
.
SKEW
SERV
ICE
LIFE
(3)
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
Inlet repl to address H Inlet issues
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
REMARKSLATITUDE LONGITUDE
LEFT
(1)
RIG
HT
(1)
CRO
SS (1
)
MED
IAN
(1)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE LE
FT (2
)
RIG
HT
(2)
IN I94 064 A 56 80769 41.591554 -87.221374 X 12 H5 INLET 3 80773 1 1 1 2IN I94 064 B 56 80773 41.591560 -87.221392 X 15 H5 INLET/STEEL PIPE 114 X 5 0 114 0 0 1 1 6 6 1 2
IN I94 064 A 57 79692 41.591821 -87.220983 X 12 H5 INLET 3 80647 3 1 1 2IN I94 064 B 57 80647 41.591819 -87.220960 X 15 H5 INLET/UKN PIPE 124 X EOL 3 0 124 0 0 1 1 6 6 1 2
IN I94 064 A 58 80713 41.592096 -87.220527 X 12 H5 INLET 3 80701 5 1 1 2IN I94 064 B 58 80701 41.592077 -87.220516 X 12 H5 INLET/STEEL PIPE 124 X 124 0 0 0 1 1 6 6 1 2
SC I94 064 59 X 15 UKN PIPE 210 EOL 0 210 0 0
SC I94 064 60 X 12 UKN PIPE 210 EOL 210 0 0 0
SC I94 064 61 X 36 UKN PIPE 210 EOL 0 0 0 210
SC I94 064 62 X 15 UKN PIPE 210 EOL 0 210 0 0
SC I94 064 64 X 12 UKN PIPE 210 EOL 210 0 0 0
IN I94 064 A 71 80662 41.595075 -87.215399 12 H5 INLET 3 80664 5 0 0 0 1IN I94 064 B 71 80664 41.595068 -87.215389 X 12 H5 INLET/UKN PIPE 182 X 5 182 0 0 0 1
IN I94 064 72 80694 41.595729 -87.214269 X 12 X5 IN/STEEL PIPE 154 X 5 154 0 0 0 1
SC I94 064 73 X 36 UKN PIPE 210 EOL 0 0 0 210
IN I94 064 74 80706 <Null> <Null> X 12 X5 INLET/UKN PIPE 150 X EOL 3 150 0 0 0 1
SC I94 064 75 X 36 UKN PIPE 210 EOL 0 0 0 21075A MANHOLE, J 1 2 1
IN I94 064 76 80362 41.596789 -87.211463 X 12 X5 INLET/UKN PIPE 50 75 3 0 0 0 1 34 50 56 50
IN I94 064 77A 80361 41.597076 -87.210170 X 14 X5 IN/STEEL PIPE 94 X 7 0 0 0 0 1
IN I94 064 78 80342 41.597325 -87.208902 X 12 X5 IN/STEEL PIPE 96 X 1 96 0 0 0 1
IN I94 064 A 80 80388 41.597655 -87.207263 X 12 H5 INLET 3 80404 3 1 1 2IN I94 064 B 80 80404 41.597634 -87.207233 X 12 H5 INLET/UKN PIPE 50 81 7 0 0 0 1 1 6 6 1 36 50 56 50
SC I94 064 81 X 36 UKN PIPE 210 EOL81A MANHOLE, J 1 2 1
IN I94 064 A 82 80387 41.597864 -87.205990 X 12 H5 INLET 3 80403 5 0 0 0 1 1 2IN I94 064 B 82 80403 41.597861 -87.205963 X 12 H5 INLET/UKN PIPE 100 X EOL 3 100 0 0 0 1 1 6 6 1 2
IN I94 064 A 83 80386 41.598283 -87.203661 X 12 H5 INLET 3 80375 5 0 0 0 1 1 2IN I94 064 B 83 80375 41.598281 -87.203688 X 12 H5 INLET/UKN PIPE 150 84 5 0 0 0 1 1 6 6 1 102 150 167 150
CV I94 064 17.40 84
SC I94 064 85 X 12 UKN PIPE 210 EOL 210 0 0 0
IN I94 064 A 86 80359 41.598537 -87.202237 X 12 H5 INLET 3 80360 5 0 0 0 1 1 2IN I94 064 B 86 80360 41.598540 -87.202229 X 12 H5 INLET/UKN PIPE 250 84 5 0 0 0 1 1 6 6 1 169 250 278 250
IN I94 064 A 87 80311 41.598912 -87.200296 X 12 H5 INLET 3 80358 5 0 0 0 1 1 2IN I94 064 B 87 80358 41.598906 -87.200300 X 12 H5 INLET/UKN PIPE 100 X EOL 5 100 0 0 0 1 1 6 6 1 2
IN I94 064 A 88 60232 41.599270 -87.198383 X 12 H5 INLET 3 60339 7 0 0 0 1 1 2IN I94 064 B 88 60339 <Null> <Null> X 12 H5 INLET/UKN PIPE 50 89 7 0 0 0 1 1 6 6 1 36 50 56 50
SC I94 064 89 X 36 UKN PIPE 210 EOL 0 0 0 21081A MANHOLE, J 1 2 1
IN I94 064 A 90 60278 41.599443 -87.197508 X 15 H5 INLET 3 60253 < 1 1 2IN I94 064 B 90 60253 41.599434 -87.197480 X 15 H5 INLET/UKN PIPE 100 X EOL r 0 100 0 0 1 1 6 6 1 2
IN I94 064 A 91 60229 41.599680 -87.196141 X 18 H5 INLET 3 60201 5 0 0 0 0 1 1 2IN I94 064 B 91 60201 41.599687 -87.196142 X 18 H5 INLET/STEEL PIPE 78 X 5 0 0 78 0 0 1 1 6 6 1 2
IN I94 064 A 93 60170 41.599928 -87.194738 X 15 H5 INLET 3 60186 7 0 0 0 1 1 2IN I94 064 B 93 60186 41.599933 -87.194756 X 18 H5 INLET/UKN PIPE 400 60201 5 0 0 0 0 1 1 6 6 1 269 400 445 400
SC I94 064 94 X 36 UKN PIPE 210 EOL 0 0 0 210
Page 1 of 3
12" 15" 18" 24" 36"
FLO
WAB
LE
BACK
FILL
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6)
PCCP
PA
TCH
ING
, FU
LL D
EPTH
MAN
HO
LE, J
PIPE
, TYP
E 1,
CI
RCU
LAR,
12
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
15
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
18
IN
PIPE
, REM
OVE
IN. LFT YRS LFT LFT LFT LFT LFT EACH CYS EACH LFT LFT EACH SYS EACH LFT LFT LFT CYS LFT
STRUCTURE DATASMALL CULVERT ID
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
LOCATION
SIZE
DESCRIPTION
LEN
GTH
OUTLET (2)
CON
NEC
T TO
STR
.
SKEW
SERV
ICE
LIFE
(3)
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
Inlet repl to address H Inlet issues
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
REMARKSLATITUDE LONGITUDE
LEFT
(1)
RIG
HT
(1)
CRO
SS (1
)
MED
IAN
(1)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE LE
FT (2
)
RIG
HT
(2)
94A MANHOLE, J 1 2 1
IN I94 064 A 95 60183 41.600341 -87.192599 X 12 H5 INLET 3 60167 7 0 0 0 1 1 2IN I94 064 B 95 60167 41.600321 -87.192571 X 15 H5 INLET/UKN PIPE 20 94 < 0 0 0 1 1 6 6 1 16 20 23 20
IN I94 064 A 96 80357 41.600555 -87.191250 X 12 H5 INLET 3 80341 5 0 0 0 1 1 2IN I94 064 B 96 80341 41.600571 -87.191243 X 15 H5 INLET/UKN PIPE 380 60167 3 0 0 0 1 1 6 6 1 256 380 423 380
IN I94 064 97 80356 41.600991 -87.188967 X 12 H5 INLET/UKN PIPE 100 X EOL < 100 0 0 0 1
SC I94 064 98 X 36 UKN PIPE 210 EOL 0 0 0 21098A MANHOLE, J 1 2 1
IN I94 064 A 99 80402 <Null> <Null> X 12 H5 INLET 3 80401 3 1 1 2IN I94 064 B 99 80401 41.601198 -87.187822 X 12 H5 INLET/UKN PIPE 25 98 7 0 0 0 1 1 6 6 1 19 25 28 25
IN I94 064 100 80284 41.601498 -87.186110 X 12 X5 INLET/UKN PIPE 100 X EOL 3 100 0 0 0 1
IN I94 064 101 80248 <Null> <Null> X 12 X5 INLET/STEEL PIPE 82 X < 82 0 0 0 1
IN I94 064 102 80280 <Null> <Null> X 12 X5 INLET/UKN PIPE 100 X EOL 5 100 0 0 0 1
SC I94 064 103 X 36 UKN PIPE 210 EOL 0 0 0 210103A MANHOLE, J 1 2 1
IN I94 064 104 80112 41.601915 -87.183550 X 12 X5 INLET/UKN PIPE 140 103 3 0 0 0 1 96 140 156 140
IN I94 064 105 80226 41.602063 -87.181808 X 12 X5 INLET/UKN PIPE 140 X EOL 5 140 0 0 0 1
IN I94 064 106 80136 41.602114 -87.180787 X 15 X5 INLET/STEEL PIPE 90 X 5 0 90 0 0 1
IN I94 064 A 107 80041 41.602114 -87.179104 X 12 H5 INLET 3 80147 5 3 0 0 0 1 1 2IN I94 064 B 107 80147 41.602127 -87.179107 X 12 H5 INLET/UKN PIPE 100 X EOL 5 100 0 0 0 1 1 6 6 1 2
IN I94 064 A 108 80161 41.602092 -87.177992 X <Null> H5 INLET 3 80040 5 0 0 0 0 1 1 2IN I94 064 B 108 80040 41.602081 -87.177992 X <Null> H5 INLET/STEEL PIPE 80 X < 0 0 0 0 1 1 6 6 1 2
IN I94 064 A 110 80109 41.602057 -87.175706 X <Null> H5 INLET 3 80108 < 1 1 2IN I94 064 B 110 80108 41.602054 -87.175693 X 12 H5 INLET/STEEL PIPE 94 X 5 94 0 0 0 1 1 6 6 1 2
IN I94 064 A 112 80075 41.602021 -87.173504 X 12 H5 INLET 3 80074 3 1 1 2IN I94 064 B 112 80074 41.602043 -87.173512 X 12 H5 INLET/UKN PIPE 25 113 5 0 0 0 1 1 6 6 1 19 25 28 25
SC I94 064 113 X 36 UKN PIPE 200 EOL 0 0 0 200113A MANHOLE, J 1 2 1
IN I94 064 A 114 80104 41.601996 -87.171941 X 12 H5 INLET 3 80122 5 0 0 0 1 1 2IN I94 064 B 114 80122 41.602018 -87.171952 X 12 H5 INLET/UKN PIPE 400 113 5 0 0 0 1 1 6 6 1 269 400 445 400
IN I94 064 A 116 80103 <Null> <Null> X 12 H5 INLET 3 80089 < 1 1 2IN I94 064 B 116 80089 41.602003 -87.170457 X 12 H5 INLET/STEEL PIPE 90 X < 90 0 0 0 1 1 6 6 1 2
IN I94 064 A 117 80084 41.601929 -87.168950 X 12 H5 INLET 3 79536 7 3 0 0 0 1 1 2IN I94 064 B 117 79536 41.601951 -87.168984 X 12 H5 INLET/STEEL PIPE 140 X 3 140 0 0 0 1 1 6 6 1 2
IN I94 064 A 118 80098 41.601935 -87.167530 X 12 H5 INLET 3 80038 < 3 0 0 0 1 1 2IN I94 064 B 118 80038 41.601941 -87.167516 X 12 H5 INLET/STEEL PIPE 100 X < 100 0 0 0 1 1 6 6 1 2
IN I94 064 A 119 72035 41.601908 -87.166087 X 12 H5 INLET 3 72050 < 3 0 0 0 1 1 2IN I94 064 B 119 72050 41.601899 -87.166096 X 12 H5 INLET/STEEL PIPE 150 X < 150 0 0 0 1 1 6 6 1 2
2744 848 0 1670 69 48 144 144 24 1411 7 1160 380 400 2161 1940QUANTITY TOTALS
Page 2 of 3
12" 15" 18" 24" 36"
FLO
WAB
LE
BACK
FILL
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6)
PCCP
PA
TCH
ING
, FU
LL D
EPTH
MAN
HO
LE, J
PIPE
, TYP
E 1,
CI
RCU
LAR,
12
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
15
IN
PIPE
, TYP
E 1,
CI
RCU
LAR,
18
IN
PIPE
, REM
OVE
IN. LFT YRS LFT LFT LFT LFT LFT EACH CYS EACH LFT LFT EACH SYS EACH LFT LFT LFT CYS LFT
STRUCTURE DATASMALL CULVERT ID
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
LOCATION
SIZE
DESCRIPTION
LEN
GTH
OUTLET (2)
CON
NEC
T TO
STR
.
SKEW
SERV
ICE
LIFE
(3)
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
Inlet repl to address H Inlet issues
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
REMARKSLATITUDE LONGITUDE
LEFT
(1)
RIG
HT
(1)
CRO
SS (1
)
MED
IAN
(1)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE LE
FT (2
)
RIG
HT
(2)
NOTES:(1) Pipe location:LEFT = Entire pipe/str location is on left side of roadway (based on stationing direction = NB/WB direction)RIGHT = Entire pipe/str location is right side of roadway (based on stationing direction = NB/WB direction)CROSS= Pipe/str location crosses under roadwayMEDIAN= Upstream end of pipe/str location is in median OR ENTIRE pipe is within median
(2) Outlet locatrion (specific to interstate median drainage): direction of outlet pipeEXAMPLE: LT = outlet pipe runs under WB (LT side) roadway and outlets
(3) SERVICE LIFE:EOL= End of Service Life (installed over 40 yrs)
(4) RP location based on RP 100th points from ArcGIS
(5) CODES:SC = small culvert (stand alone culvert)IN = inlet (with downstream pipe to another STR or outlet)MH = manhole (with downstream pipe to another STR or outlet)
(6) INLET, MEDIAN, MODIFIED same as FDOT Inlet, Median, Type 2
(7) INDOT standard pipe trench dimensions were not used for trench backfill. Vertical wall trench with 1' of room each side of pipe wall was used for backfill.
Page 3 of 3
12" 15" 24" 36" 42"
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6) 12" 15" 24" 36" 42"
IN. LFT YRS LFT LFT LFT LFT LFT EACH LFT EACH LFT LFT EACH LFT LFT LFT LFT LFT CYS EACH EACH TON TON TON
330#
/SYS
QC/
QA
HM
A, 3
, 70,
SFC
E,
12.5
MM
LEFT
(1)
RIG
HT
(1)
MED
IAN
(1)
SIZE
CON
NEC
T TO
STR
.
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE
DESCRIPTION
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
MED
IAN
T
CON
NEC
TIO
N (
6)
PIPE, TYPE 1
MAN
HO
LE J
MAN
HO
LE D
STRUCTURE DATALOCATION
REMARKS
LEN
GTH
SERV
ICE
LIFE
(3)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
SMALL CULVERT ID
440#
/SYS
QC/
QA
HM
A, 3
, 64,
BAS
E,
25.0
MM
880#
/SYS
QC/
QA
HM
A, 3
, 70,
IN
T,
19.0
MM
PIPE
, ABA
ND
ON
&
GRO
UT
FILL
LATITUDE
H5 Inlet Repl
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
LONGITUDE
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
CRO
SS (1
)
OUTLET (2)
LEFT
(2)
RIG
HT
(2)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
IN I94 064 11 71492 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1
IN I94 064 A 12 72018 X 12 H5 INLET 3 71732 3 0 0 0 0 1 1IN I94 064 B 12 71732 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 1 8 8 1
IN I94 064 A 12A 72049 X 12 H5 INLET 3 72033 X 3 0 0 0 0 1 1IN I94 064 B 12A 72033 X 12 H5 INLET 450 72001 X REPL. 0 0 0 0 1 450 1 8 8 1 460 0 0 0 0 512 1 85 225 113
IN I94 064 A 13 72017 X 12 H5 INLET 3 72001 X 3 0 0 0 0 1 1IN I94 064 B 13 72001 X 12 H5 INLET/FBCCS PIPE 120 X X EOL 130 0 0 0 0 1 0 1 8 8 1 10 0 0 0 0 1
IN I94 064 A 14 71368 X 12 H5 INLET 3 71734 3 0 0 0 0 1 1IN I94 064 B 14 71734 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 15 71773 X 12 H5 INLET 3 71684 3 0 0 0 0 1 1IN I94 064 B 15 71684 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 16 71732 X 12 H5 INLET 3 71341 3 0 0 0 0 1 1IN I94 064 B 16 71341 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 17 71716 X 12 H5 INLET 3 71731 3 0 0 0 0 1 1IN I94 064 B 17 71731 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 18 71340 X 12 H5 INLET 3 71491 3 0 0 0 0 1 1IN I94 064 B 18 71491 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 19 71725 X 12 H5 INLET 3 71490 X 3 0 0 0 0 1 1IN I94 064 B 19 71490 X 12 H5 INLET 10 20 X REPL. 0 0 0 0 1 10 1 8 8 1 20 0 0 0 0 23 1 4 10 5
SC I94 064 20 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
SC I94 064 21 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 22 71366 X 12 H5 INLET 3 71367 X 3 0 0 0 0 1 1IN I94 064 B 22 71367 X 12 H5 INLET 20 21 X REPL. 0 0 0 0 1 20 1 8 8 1 30 0 0 0 0 34 1 6 15 8
SC I94 064 23 X 42 FBCCS PIPE 340 EOL 0 0 0 0 340
IN I94 064 A 24 67729 X 12 H5 INLET 3 71365 3 0 0 0 0 1 1IN I94 064 B 24 71365 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 25 67713 X 12 H5 INLET 3 71339 X 3 0 0 0 0 1 1IN I94 064 B 25 71339 X 12 H5 INLET 20 26 X REPL. 0 0 0 0 1 20 1 8 8 1 30 0 0 0 0 34 1 6 15 8
CV I94 064 21.10 26 X TWIN 76x44 RECP
IN I94 064 27 71338 X 12 X5 INLET 175 26 X 175 0 0 0 0 1 1
IN I94 064 A 28 67697 X 12 H5 INLET 3 71683 X 3 0 0 0 0 1 1IN I94 064 B 28 71683 X 12 H5 INLET 10 29 X REPL. 0 0 0 0 1 10 1 8 8 1 20 0 0 0 0 23 1 4 10 5
SC I94 064 29 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 30 67681 X 12 H5 INLET 3 71730 3 0 0 0 0 1 1IN I94 064 B 30 71730 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
CV I94 064 21.70 31 X 48 1
IN I94 064 A 32 67665 X 12 H5 INLET 3 71714 X 3 0 0 0 0 1 1IN I94 064 B 32 71714 X 12 H5 INLET 15 31 X REPL. 0 0 0 0 1 15 1 8 8 1 25 0 0 0 0 28 1 5 13 7
IN I94 064 A 33 67649 X 12 H5 INLET 3 71698 3 0 0 0 0 1 1IN I94 064 B 33 71698 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
CV I94 064 22.00 34 X 54
IN I94 064 35 X 12 ?? INLET 70 X EOL 70 0 0 0 0 1
IN I94 064 36 X 12 ?? INLET 70 X EOL 70 0 0 0 0 1
IN I94 064 37 X 12 ?? INLET 70 X EOL 70 0 0 0 0 1
IN I94 064 38 X 12 ?? INLET 70 X EOL 70 0 0 0 0 1
IN I94 064 A 39 71729 X 12 H5 INLET 3 65841 3 0 0 0 0 1 1IN I94 064 B 39 65841 X 15 H5 INLET/FBCCS PIPE 120 X EOL 0 120 0 0 0 1 0 1 8 8 1
IN I94 064 A 40 67621 X 12 H5 INLET 3 71713 3 0 0 0 0 1 1
12" 15" 24" 36" 42"
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6) 12" 15" 24" 36" 42"
IN. LFT YRS LFT LFT LFT LFT LFT EACH LFT EACH LFT LFT EACH LFT LFT LFT LFT LFT CYS EACH EACH TON TON TON
330#
/SYS
QC/
QA
HM
A, 3
, 70,
SFC
E,
12.5
MM
LEFT
(1)
RIG
HT
(1)
MED
IAN
(1)
SIZE
CON
NEC
T TO
STR
.
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE
DESCRIPTION
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
MED
IAN
T
CON
NEC
TIO
N (
6)
PIPE, TYPE 1
MAN
HO
LE J
MAN
HO
LE D
STRUCTURE DATALOCATION
REMARKS
LEN
GTH
SERV
ICE
LIFE
(3)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
SMALL CULVERT ID
440#
/SYS
QC/
QA
HM
A, 3
, 64,
BAS
E,
25.0
MM
880#
/SYS
QC/
QA
HM
A, 3
, 70,
IN
T,
19.0
MM
PIPE
, ABA
ND
ON
&
GRO
UT
FILL
LATITUDE
H5 Inlet Repl
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
LONGITUDE
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
CRO
SS (1
)
OUTLET (2)
LEFT
(2)
RIG
HT
(2)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
IN I94 064 B 40 71713 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 41 67620 X 12 H5 INLET 3 71697 3 0 0 0 0 1 1IN I94 064 B 41 71697 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 42 67530 X 12 H5 INLET 3 71352 3 0 0 0 0 1 1IN I94 064 B 42 71352 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
CV I94 064 23.00 43 X 10x10 CONC BOX
IN I94 064 A 45A 67558 X 12 H5 INLET 3 X 3 0 0 0 0 1 1IN I94 064 B 45A 71682 X 12 H5 INLET 94 43 X REPL. 0 0 0 0 1 94 1 8 8 1 104 0 0 0 0 116 1 20 51 26
IN I94 064 A 47 67557 X 12 H5 INLET 3 71681 3 0 0 0 0 1 1IN I94 064 B 47 71681 X 12 H5 INLET/FBCCS PIPE 120 X EOL 0 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 48 67619 X 12 H5 INLET 3 71337 3 0 0 0 0 1 1IN I94 064 B 48 71337 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
SC I94 064 49 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0
IN I94 064 A 50 67528 X 12 H5 INLET 3 84276 3 0 0 0 0 1 1IN I94 064 B 50 84276 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
SC I94 064 51 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0
IN I94 064 A 52 67618 X 12 H5 INLET 3 84275 X 3 0 0 0 0 1 1IN I94 064 B 52 84275 X 12 H5 INLET/FBCCS PIPE 12 53 X EOL REPL. 0 0 0 0 1 12 1 8 8 1 22 0 0 0 0 25 1 5 11 6
SC I94 064 53 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 54 67586 X 12 H5 INLET 3 67633 3 0 0 0 0 1 1IN I94 064 B 54 67633 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 55 67602 X 12 H5 INLET 3 84337 8 3 0 0 0 0 1 1IN I94 064 B 55 84337 X 12 H5 INLET/FBCCS PIPE 120 X EOL 9 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 56 67572 X 12 H5 INLET 3 84321 3 0 0 0 0 1 1IN I94 064 B 56 84321 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
IN I94 064 A 57 84290 X 12 H5 INLET 3 66859 3 0 0 0 0 1 1IN I94 064 B 57 66859 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
SC I94 064 24.62 58 X 42 FBCCS PIPE 210 EOL 0 0 0 0 210
SC I94 064 24.83 59 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0
IN I94 064 A 60 84305 X 12 H5 INLET 3 66927 3 0 0 0 0 1 1IN I94 064 B 60 66927 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
SC I94 064 24.96 61 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0
IN I94 064 A 62 84274 X 12 H5 INLET 3 66876 X 3 0 0 0 0 1 1IN I94 064 B 62 66876 X 12 H5 INLET/FBCCS PIPE 15 61 X EOL REPL. 0 0 0 0 1 15 1 8 8 1 25 0 0 0 0 28 1 5 13 7
SC I94 064 25.02 63 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 64 66926 X 12 H5 INLET 3 84289 X 3 0 0 0 0 1 1IN I94 064 B 64 84289 X 12 H5 INLET/FBCCS PIPE 12 63 X EOL REPL. 0 0 0 0 1 12 1 8 8 1
IN I94 064 A 64A 66933 X 12 H5 INLET 3 84273 X 3 0 0 0 0 1 1IN I94 064 B 64A 84273 X 12 H5 INLET/FBCCS PIPE 290 65 X EOL REPL. 0 0 0 0 1 290 1 8 8 1 300 0 0 0 0 334 1 55 147 74
SC I94 064 25.22 65 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 66 66932 X 12 H5 INLET 3 84258 X 3 0 0 0 0 1 1IN I94 064 B 66 84258 X 12 H5 INLET/FBCCS PIPE 15 65 X EOL REPL. 0 0 0 0 1 15 1 8 8 1 25 0 0 0 0 28 1 5 13 7
IN I94 064 A 67 84254 X 12 H5 INLET 3 66875 3 0 0 0 0 1 1IN I94 064 B 67 66875 X 12 H5 INLET/PLASTIC PIPE 15 68 EOL 15 0 0 0 0 1 0 1 8 8 1 0 0 0 0 0 0 0 0 0
CV I94 064 25.70 68 X 72" FBCCS 1
IN I94 064 A 69 66925 X 12 H5 INLET 3 84241 3 0 0 0 0 1 1IN I94 064 B 69 84241 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
SC I94 064 25.94 71 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0
12" 15" 24" 36" 42"
INLE
T,
REM
OVE
BARR
IER
WAL
L, C
ON
C,
REM
CON
CRET
E BA
RRIE
R
INLE
T,
MED
IAN
, MO
D
(6) 12" 15" 24" 36" 42"
IN. LFT YRS LFT LFT LFT LFT LFT EACH LFT EACH LFT LFT EACH LFT LFT LFT LFT LFT CYS EACH EACH TON TON TON
330#
/SYS
QC/
QA
HM
A, 3
, 70,
SFC
E,
12.5
MM
LEFT
(1)
RIG
HT
(1)
MED
IAN
(1)
SIZE
CON
NEC
T TO
STR
.
PIPE
TYP
E MANHOLE, INLET, CATCH BASIN, OR
SPECIALTY STRUCTURE AND TYPE
DESCRIPTION
FLO
WAB
LE
BACK
FILL
, RE
MO
VABL
E (7
)
MED
IAN
T
CON
NEC
TIO
N (
6)
PIPE, TYPE 1
MAN
HO
LE J
MAN
HO
LE D
STRUCTURE DATALOCATION
REMARKS
LEN
GTH
SERV
ICE
LIFE
(3)
GIS
OBJ
ECT
ID(T
his
colu
me
may
hid
e)
SMALL CULVERT ID
440#
/SYS
QC/
QA
HM
A, 3
, 64,
BAS
E,
25.0
MM
880#
/SYS
QC/
QA
HM
A, 3
, 70,
IN
T,
19.0
MM
PIPE
, ABA
ND
ON
&
GRO
UT
FILL
LATITUDE
H5 Inlet Repl
PIPE
CO
ND
ITIO
N PIPE LINER, CIP
CAST
ING
5,
FURN
ISH
& A
DJ
TO G
RAD
E
LONGITUDE
STRU
CTU
RE
NU
MBE
R(F
rom
old
pla
ns;
hide
col
umn)
CRO
SS (1
)
OUTLET (2)
LEFT
(2)
RIG
HT
(2)
COD
E (5
)
ROU
TE
COU
NTY
RP (4
)
STR
DES
IGN
ATIO
N
IN I94 064 A 72 66888 X 12 H5 INLET 84225 X 0 0 0 0 0 1 1IN I94 064 B 72 84225 X 12 H5 INLET/FBCCS PIPE 35 71 X EOL REPL. 0 0 0 0 1 35 1 8 8 1
IN I94 064 A 73 66924 X 12 H5 INLET 3 84209 X 3 0 0 0 0 1 1IN I94 064 B 73 84209 X 12 H5 INLET/FBCCS PIPE 90 74 X EOL REPL. 0 0 0 0 1 90 1 8 8 1
SC I94 064 26.03 74 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 75 66874 X 12 H5 INLET 3 84179 3 0 0 0 0 1 1IN I94 064 B 75 84179 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
CV I94 064 26.20 76 X 45x29 RECP W/L
SC I94 064 26.23 77 X 36 FBCCS PIPE 210 EOL 0 0 0 210 0 1
IN I94 064 A 78 66873 X 12 H5 INLET 3 84193 X 3 0 0 0 0 1 1IN I94 064 B 78 84193 X 12 H5 INLET/FBCCS PIPE 90 77 X EOL REPL. 0 0 0 0 1 90 1 8 8 1
IN I94 064 A 79 84178 X 12 H5 INLET 3 66923 3 0 0 0 0 1 1IN I94 064 B 79 66923 X 12 H5 INLET/FBCCS PIPE 120 X EOL 120 0 0 0 0 1 0 1 8 8 1
3600 120 0 2730 550 88 1178 82 328 328 41 1071 0 0 0 0 1185 21 2 200 523 266
NOTES:(1) Pipe location:LEFT = Entire pipe/str location is on left side of roadway (based on stationing direction = NB/WB direction)RIGHT = Entire pipe/str location is right side of roadway (based on stationing direction = NB/WB direction)CROSS= Pipe/str location crosses under roadwayMEDIAN= Upstream end of pipe/str location is in median OR ENTIRE pipe is within median
(2) Outlet locatrion (specific to interstate median drainage): direction of outlet pipeEXAMPLE: LT = outlet pipe runs under WB (LT side) roadway and outlets
(3) SERVICE LIFE:EOL= End of Service Life (installed over 40 yrs)
(4) RP location based on RP 100th points from ArcGIS
(5) CODES:SC = small culvert (stand alone culvert)IN = inlet (with downstream pipe to another STR or outlet)MH = manhole (with downstream pipe to another STR or outlet)
(6) MEDIAN T CONNECTION = H5 inlets outlet/inlet with T connection under conc median barrier
(7) INDOT standard pipe trench dimensions were not used for trench backfill. Vertical wall trench with 1' of room each side of pipe wall was used for backfill.
QUANTITY TOTALS
Route: I94 Des. No.: CN Est: $10,739,380.92Project Limits: MP16 to MP26, Median Drainage Rehab Contract No.: ADA ITEMS:
Item Number Item DescriptionSupplemental
DescriptionQuantity Unit Unit Price Extension Remarks
202-02240 PAVEMENT REMOVAL 1411 SYS $35.00 $49,385.00202-02637 PIPE, ABANDON AND GROUT FILL 1178 LFT202-91385 INLET, REMOVE 130 EACH $600.00 $78,000.00202-94954 BARRIER WALL, CONCRETE, REMOVE 472 LFT $50.00 $23,600.00202-96133 PIPE, REMOVE 1940 LFT $30.00 $58,200.00213-09269 FLOWABLE BACKFILL, NON-REMOVABLE 260 CYS $220.00 $57,200.00213-09270 FLOWABLE BACKFILL, REMOVABLE 3346 CYS $200.00 $669,200.00
401- QC/QA-HMA, 5, 76, SURFACE, 9.5 MM 200 TON $95.00 $19,000.00401- QC/QA-HMA, 5, 76, INTERMEDIATE, 19.0 MM 523 TON $75.00 $39,225.00401- QC/QA-HMA, SURFACE, 266 TON $68.00 $18,088.00
506-06333 PCCP PATCHING, FULL DEPTH 1411 SYS $250.00 $352,750.00602-01064 CONCRETE BARRIER 472 LFT $150.00 $70,800.00616-05688 RIPRAP, CLASS 1 4428 TON $100.00 $442,800.00616-12246 GEOTEXTILE FOR RIPRAP TYPE 1A 4305 SYS $25.00 $107,625.00715-05118 PIPE, TYPE 1, CIRCULAR, 12 IN. 2231 LFT $50.00 $111,550.00715-05119 PIPE, TYPE 1, CIRCULAR, 15 IN. 380 LFT $55.00 $20,900.00715-05121 PIPE, TYPE 1, CIRCULAR, 18 IN. 400 LFT $65.00 $26,000.00720-01894 CASTING, FURNISH AND ADJUST TO GRADE 157 EACH $3,000.00 $471,000.00720-45431 MANHOLE, J 28 EACH $10,000.00 $280,000.00720-45415 MANHOLE, D4 2 EACH $15,000.00 $30,000.00720-99999 INLET, MEDIAN, TYPE 2 65 EACH $8,200.00 $533,000.00 FDOT Pay Item & Detail used for this item725-08293 PIPE LINER, CURED-IN-PLACE, 36 IN 4400 LFT $250.00 $1,100,000.00725-08294 PIPE LINER, CURED-IN-PLACE, 42 IN 550 LFT $350.00 $192,500.00725-08298 PIPE LINER, CURED-IN-PLACE, 15 IN 1062 LFT $180.00 $191,160.00725-11275 PIPE LINER, CURED-IN-PLACE, 12 IN 6344 LFT $160.00 $1,015,040.00725-9999 PIPE LINER, CURED-IN-PLACE, 18 IN 78 LFT $210.00 $16,380.00801-08400 TEMPORARY TRAFFIC BARRIER, TYPE 1 16000 LFT $35.00 $560,000.00 Use 3 miles of TCB for WZ safety
MOT SPECIFIC ITEMS801- MOT SCHEME BASE COST 15,000 LSUM $1.00 $15,000.00 DETOUR
SUBTOTAL $6,548,403.00105-06807 ADDITIONAL, CONTINGENCY 25% 1 LS $1,637,100.75 $1,637,100.75105-06845 CONSTRUCTION ENGINEERING 4% 1 LS $261,936.12 $261,936.12 USE 4% OF CN COST FOR SCOPE EST110-01001 MOBILIZATION AND DEMOBILIZATION 8% 1 LS $523,872.24 $523,872.24 USE 6% OF CN COST FOR SCOPE EST201-52370 CLEARING R/W 8% 1 LS $523,872.24 $523,872.24 USE 2% OF CN COST FOR SCOPE EST
205- STORM WATER MANAGEMENT 5% 1 LS $327,420.15 $327,420.15 USE 2% OF CN COST FOR SCOPE EST801-06775 MAINTAINING TRAFFIC 10% 1 LS $654,840.30 $654,840.30 USE 4% OF CN COST FOR SCOPE EST
808- PAVEMENT MARKING ITEMS 4% 1 LS $261,936.12 $261,936.12 USE 4% OF CN COST FOR SCOPE EST
PROJECT QUANTITY SUMMARY TABLE
STORM SEWER ABANDONMENT AND REMOVAL
Description This work shall consist of the abandonment of temporary and existing storm
sewer pipe and structures by removing or grouting pipe interior. Materials A cement based grout shall be used to fill the void of the temporary storm
sewer to be abandoned in place. The grouting material shall have a strength of at least 100 psi and shall have flow characteristics appropriate for filling a storm sewer. The grout mix design and method of installation shall be approved by the Engineer prior to beginning the operation.
Construction Requirements Remove the castings and portions of the temporary structures to allow for
milling and pavement operations. Fill the remaining section of temporary structure with grout. Temporary structures shall be abandoned prior to milling and paving operations.
The entire interior void space within the temporary and existing storm
sewer pipe located under the roadway and shoulders shall be filled with grout after the end is sealed. The grout shall cure and harden in the physical environment and prevent collapse of the pipe wall.
Temporary storm sewer pipe no longer in use and not filled with grout shall
be removed as shown on the plans or as directed. Method of Measurement The remove of castings and portions of the temporary structures will not be
measured for payment. Abandonment of pipe and temporary pipe removed will be measured by the
linear foot.
Basis of Payment The accepted quantities of abandon and grout filled and temporary pipe
removed will be paid for at the contract unit price per linear foot. Payment will be made under: Pay Item Pay Unit Symbol Pipe, Abandon and Grout Fill...............................LFT
Pipe, Remove, Temporary....................................LFT Removing casting and sections of the temporary structure and filling structure with grout shall be incidental to the pipe abandonment. Placing a bulkhead at the ends of existing pipe prior to grout fill shall be incidental to the pipe abandonment.
Casting and temporary pipe shall remain property of the Contractor upon completion of the contract.
GENERAL NOTES:
A A
B
B
DEPTH
WALLSCHEDULE
(in.²/ft.)
AREA MAX. SPACING
BARS WWF
A6
0.20
0.20
0.24
0.37
6"
0'-3'
3'-6'
12"
6'-9'
9'-15'
5"
6"
5"
8"A12
B5.5
C6.5
"215
"216
Cast-In-Place
Precast
Cast-In-Place
Precast
5'-4"
5'-0"
6"
4" 6"
6" 3'-4"
3'-4"
6" 6"
4"6"
Wall
Depth
Varie
s (1
5'
Max.)
6"
*8"
6"
Cast-In-Pla
ce
Precast
Or
Precast 6"
8"
4'-0"
4'-0"
6"
8" Cast-In-Place
Precast
Cl.
3"
6"
Min.
Cl.
"2
11
3"
Min.
Cl.
"211
Cl.
2"
2" Cl. (C-I-P)
" Cl. (Precast)211
For Min. Dimensions
These Limits See Index 425-001
Const. Joint Permitted Between *
3'-1"
2'-11"
C-I-P Collar
Precast Collar
2" 6"
4"
1'-
8"
3" Cl.*
Cast-In-Place
Precast6"
8"2'-0"
2'-0"6"
8"
1'-5"7"
3"
8"
6" 4'-10" Std.
4'-10" Std.
Precast
Cast-In-Place8"
6"
3" Cl.
*
Called For In The Pla
ns
Or S
pecial
Only
When
Alt.
B Structure B
otto
m
1'-5"7"
1'-
5"
7"1'-5"
Shoulder P
avement
" Max.)
21
(1"
Min., 1
Varie
s as Reqd.
Cast-In-Place (Typ.)
Precast (Typ.)3'-
2" (M
edia
n Barrier)
(See
Note 4)
3'-
2" (M
edia
n Barrier)
(See
Note 4)
3" (T
yp.)
3'-1"
2'-11"
C-I-P Collar
Precast Collar
3'-
2" (M
edia
n Barrier)
(See
Note 4)
"2
12
" Cover
21
2
(Top & S
ides)
Others Similar)
(Inlet Type 1 Shown,
PLAN
3'-0"
Inlet Opening
3'-0"(See
Note 4)
Shoulder Pavt. Taper Shoulder Pavt. Taper
38"
Media
n Barrier
C
C
(Grate Not Shown for Clarity)
ELEVATION - VIEW C-C
C
C
INLET DETAIL
(Pipe Opening Shown)
for Inlet Type 2
Mirror About
�
Concrete B
arrier Tran
sition
SYMMETRICAL HEIGHT BARRIER SIMILAR)
(GRADE-SEPARATED BARRIER SHOWN,
SECTION FOR INLET TYPE 2
WALL REINFORCING SCHEDULE
TABLE 1: HORIZONTAL
(SYMMETRICAL HEIGHT BARRIER ONLY)
SECTION FOR INLET TYPE 1
(Pipe Opening Not Shown)
SECTION B-B
SECTION A-A
ISOMETRIC VIEW
including footings.
Type III organic felt between inlet and barrier,
10. Bond Breaker: One layer of ASTM D6380 Class S,
for Concrete Barrier, LF.
Barrier to be paid for under the contract unit price
for Inlets (Median Barrier Type_), EA. Concrete
Inlets to be paid for under the contract unit price 9.
cast-in-place inlets unless otherwise noted.
All dimensions are for both precast and 8.
For supplemental details see Index 425-001.7.
the adjacent barriers; use lap splices as required.
and run continuously with the longitudinal steel of
the full length of the Concrete Barrier Transition
adjacent barrier. Run Longitudinal steel bars over
otherwise shown. Match the stirrup spacing of the
adjacent barrier reinforcing cover, unless
" as needed to match the 21may be either 2" or 2
per Index 521-001. Barrier reinforcing steel cover
longitudinal steel of the adjacent Concrete Barrier
bars, as required to match the stirrups and
Barrier reinforcing is Grade 60 #4 bars or #5 6.
fabric is permitted.
Index 425-001, the equivalent area of welded wire
from the inside face unless otherwise shown. Per
horizontal wall reinforcing must be positioned 3"
5. Inlet wall reinforcing is Grade 60 #4 bars. The
requirements, see Index 521-001.
For standard Median Barrier dimensions and 4.
" radius.41or tooled to
" chamfer 43All exposed edges and corners shall be 3.
pedestrian traffic or bicycle way.
pedestrian traffic. Not suitable for use in
anticipated. Used in areas of occasional
shall be specified where bicycle traffic is
is called for in the plans. The reticuline grate
bar grate shall be used unless the reticuline grate
For grate details, see Index 425-020. The parallel 2.
Type 2: Inlet on both sides of Median Barrier
Type 1: Inlet on one side of Median Barrier
Inlet Descriptions:
conjunction with Median Barrier per Index 521-001.
Where called for in the Plans, use this inlet in 1.
11/01/17 425-030 1 2MEDIAN BARRIER INLETS TYPES 1 AND 2
3/21/2018
8:1
0:0
9
AM
RE
VISIO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2018-19 SHEETINDEX
@ 9" Ctrs.
#4 Bars
Opening
Above Pipe
Each Side and
1 Extra ~ #4 Bar
(See Table 1)
Horiz. Wall Reinf.
@ 12" Ctrs.
#4 Bars
Bond Breaker
9" Ctrs.
#4 Bars @
2 Extra
Horiz. Wall Reinf. (See Table 1)
#4 Bars @ 12" Ctrs.
Or 8" Ctrs. (Precast 6" Slab)
#4 Bars @ 12" Ctrs. (8" Slab)#4 Bars @ 12" Ctrs.
Bars @ 9" Ctrs.
2 Extra #4
#4 Bars @ 12" Ctrs.
(See Table 1)
Horiz. Wall Reinf.
Bond Breaker
@ 9" Ctrs.
#4 Bars
2 Extra
" Ctrs. (Precast 6" Slab)21Or 4
#4 Bars @ 9" Ctrs. (8" Slab)" Ctrs. (Precast 6" Slab)2
1Or 3
#4 Bars @ 6" Ctrs. (8" Slab)
& Inlet Structure
¡ Median Barrier
Optional
Shape
Haunch
(Typ.)
GP.
Theo.
Note 6
See
Note 6
See
Back of Throat
(Gutter Line)
Barrier GP Line
of Throat
Top Back
(Gutter Line)
Barrier GP. Line
Taper (Typ. as Reqd.)
Shoulder Pavement
Pavt. Taper (Typ.)
Edge of Shoulder
� Median Barrier
Pavt.
Shldr.
Pavt.
Shldr.
Pavt.
Shldr.
Pavt.
Shldr.
Index 425-001)
Eyebolt (See
Adjacent Barrier
Match Slope of
of Throat
Top Back
" Max.)215
" Min., 21(4
Throat Opening
Throat Opening
1:5 For Shoulder Slope ≥0.071:6 For Shoulder Slope <0.07
Grate Slope:
Barrier Deeper)
Shown, Grade-Separated
(Symmetrical Barrier
Barrier Footing (Typ.)
Bottom of Median
� Inlet
Barrier Only)
(Symmetrical Height
¡ Median Barrier
Barrier)
Symmetrical
(Omit if
Varies
(Typ.)
Throat Taper
Sheet 2)
Collar (See
Sheet 2)
Collar (See
of Throat
Top FrontSta./Offset Location
(Typ.)
Theo. GP.
Sta./Offset Location
5"
3"
"16
55
(C-I-P COLLAR REINFORCING DETAILS SIMILAR)
PRECAST COLLAR REINFORCING DETAILS (TYPE 1)
(C-I-P COLLAR REINFORCING DETAILS SIMILAR)
PRECAST COLLAR REINFORCING DETAILS (TYPE 2)
10/16/2017
8:4
3:2
8
AM
RE
VISIO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2018-19 SHEETINDEX
11/01/17 425-030 2 2MEDIAN BARRIER INLETS TYPES 1 AND 2
Shape Optional
Haunch
(1:6
Grate Slo
pe)
(1:5
Grate Slo
pe)
(1:6
Grate Slo
pe)
(1:5
Grate Slo
pe)
TOP VIEW OF INLET COLLAR WITHOUT GRATE SECTION HHTOP VIEW OF INLET COLLAR WITHOUT GRATESECTION EE
VIEW FFSECTION DDVIEW JJVIEW KK
C-I-P
Precast
C-I-P
Precast
"8
31'-
10
1'-
10"
"8
31'-
11
1'-
11"
Slo
pe)
(1:5
Grate
Slo
pe)
(1:6
Grate
6" C-I-P4" Precast
2" 1'-5"
4" Pre
cast
6" C-I-P
Varie
s
5'-4"
C-I-
P
5'-0" Pr
ecast
Prec
astC-
I-P
2'-8"2'-6"
10"
10"
2'-6"
2'-8"
1'-
5"
6'-2" C-I-P
5'-10" Precast
Varie
s
C-I-P
Precast
C-I-P
Precast
"8
31'-
10
1'-
10" "8
31'-
11
1'-
11"
(1:5
Grate Slo
pe)
(1:6
Grate Slo
pe)
6" C-I-P4" Precast
2" 1'-5"
4" Pre
cast6"
C-I-P
8" C-I-P6" Precast
1'-
8"
5'-4"
C-I-
P
5'-0" Pr
ecast
3'-0" Precast
3'-4" C-I-P
3"
5'-0"
3 Spaces @ 12" 6" 4"6"4"
3'-
0"
3 S
paces
@ 9"
@ 12"
2 S
paces
F F
DD
E
E
3'-0"
6" 2" 4"
9" F.S.
3 Spaces @
@ 12" N.S.
2 Spaces
1'-
8"
9"
2"
Cl.
2"
Cl.
3" Cl. 3" Cl.
1'-
11"
1'-
10"9"
2"
Cl.
(1:6
Grate Slo
pe)
(1:5
Grate Slo
pe)
5'-0"
3 Spaces @ 12"
2"
Cl.
(1:6
Grate Slo
pe)
(1:5
Grate Slo
pe)
1'-
11"
1'-
10"9
"
Varie
s2"
Cl.6"4"4"6"
" Cl.211
" Cl.211
2" Cl.
5'-0"
6" 4"6"4"
3"
9"
Varie
s
Varie
s
2"
Cl.
6" 4" 4" 6"
2" Cl."8
35
" Cl.211
6" 4" 4" 6"
Varie
s
9"
1'-
10"
1'-
11"
2"
Cl.
3 Spaces @ 12"
5'-0"
2" Cl.
6" 4" 4" 6"
12"
Ctrs.
Bars
@
12"
9"
2"
Cl.
2" Cl." Cl.211
Varie
s
3 Spaces @ 12"
5'-0"
Varie
s
Spacin
g
12"
Max.
Spacin
g
12"
Max.
12"
9"
2"
Cl.
3" Cl.
15"
5 Spaces @ 12"
7 Spaces @ 9"
5'-10"
3" Cl. 12"
1'-
10"
1'-
11"
9"
2"
Cl.
10"
5'-
10"
7 S
paces
@ 9"
5 S
paces
@ 12"
±
10"
3 Spaces @ 12"
5'-0"
6"4" 6" 4"
K K
H
H JJ
COLLAR (TYPE 1)
ISOMETRIC VIEW OF INLET
COLLAR (TYPE 2)
ISOMETRIC VIEW OF INLET