© Copyright year ABB. All rights reserved. -1- 4/27/2011 Insert image here Web Browser facility

ABB

Embed Size (px)

DESCRIPTION

gearhart logging

Citation preview

Page 1: ABB

©C

opyr

ight

yea

r AB

B.

All

right

s re

serv

ed. -

1-

4/27

/201

1

� Insert image here

Web Browser facility

Page 2: ABB

©C

opyr

ight

yea

r AB

B -

2-

Introduction Of Web Browser

How to access RTU560?

� RTU560 use Standard Web browser interface to Access� Internet Explorer

� Firefox mozilla

� Google Chrome

� Ethernet Interface – convenient & easy to use

Page 3: ABB

©C

opyr

ight

yea

r AB

B -

3-

Introduction Of Web Browser

What is the purpose of Web Browser?

� To provide system diagnosisfunctionality

� To provide Process diagnosisfunctionality

� Loading RTU 560 configuration files

� Loading RTU 560 firmware

� To access local archive function

� Administration of the web server

Page 4: ABB

©C

opyr

ight

yea

r AB

B -

4-

Accessing the WEB Browser

The web browser could be access through

� MMI port on the CPU card SLIO2 or ETH 02/ 03

� Ethernet connection via Ethernet RJ 45 port over ETH 02/03 CPU card

� Ethernet connection via E1/E2 on CMU05 – Pantai Remis is using this CMU

Page 5: ABB

©C

opyr

ight

yea

r AB

B -

5-

Accessing the WEB Browser

Prerequisite to use :

� Normal LAN cable

� Knowledge about TCP/IP

Page 6: ABB

©C

opyr

ight

yea

r AB

B -

6-

Ethernet

23ET24 Subarack

Accessing the web browser to 560CMU05

� 4 ethernet port available 2 x E1, 2 x E2

� Misconception : Port 1,2, A & B are not Ethernet port, they are serial port

Ethernet

Page 7: ABB

©C

opyr

ight

yea

r AB

B -

7-

560CMU05 on 23ET24

Accessing the web browser

LAN/ WAN infra structure

Station access

*Remote access

*This only possible is the RTU has acces to TNB’s WAN

Page 8: ABB

©C

opyr

ight

yea

r AB

B -

8-

Setting up the network Accessing the RTU

� To access, connect your PC LAN port with RTU’s E1

� Change your PC’s IP address to be in the domain

� Set the IP to 192.168.0.xx for connecting to E1

� Set the IP to 192.168.1.xx for connecting to E2

� Once this has set, start the Mozilla, Google chrome or internet Explorer

� Type RTU IP’s on the address section : 192.168.0.1

Page 9: ABB

©C

opyr

ight

yea

r AB

B -

9-

Setting up the network Accessing the RTU: sample Google Chrome

Page 10: ABB

©C

opyr

ight

yea

r AB

B -

10-

Common Problem Unable to connect to the Internet

Page 11: ABB

©C

opyr

ight

yea

r AB

B -

11-

Common Problem : Google Chrome Check the internet option setting ->

Option

Page 12: ABB

©C

opyr

ight

yea

r AB

B -

12-

Common Problem : Google Chrome Check the internet option setting

Under the hood

Network: Change proxy setting

Page 13: ABB

©C

opyr

ight

yea

r AB

B -

13-

Common Problem : Google Chrome Check the internet option setting

Select LAN setting

Un-tick all the boxes and press OK button

Then try again to access via google chrome

Page 14: ABB

©C

opyr

ight

yea

r AB

B -

14-

Common Problem : Mozilla FirefoxCheck the internet option setting- Tools/Option

Option

Page 15: ABB

©C

opyr

ight

yea

r AB

B -

15-

Common Problem : Mozilla FirefoxCheck the internet option setting- Tools/Option

Setting

Set to No Proxy

Press OK and try again to use the Mozilla Firefox

Page 16: ABB

©C

opyr

ight

yea

r AB

B -

16-

Common Problem : Ping Test Here is another simple test to verify connection.

Some PC’s has the IP’s locked so need to unlock before you can use it.

To test whether the IP is already changed

Go to Start->run

Type in the Open box : CMD

Then press OK

Page 17: ABB

©C

opyr

ight

yea

r AB

B -

17-

Common Problem : Ping Test Here is another simple test to verify connection.

Some PC’s has the IP’s locked so need to unlock before you can use it.

To test whether the IP is already changed

Go to Start->run

Type in the Open box : CMD

Then press OK

Page 18: ABB

©C

opyr

ight

yea

r AB

B -

18-

Common Problem : Ping Test Type IPCONFIG, this will give IP configuration of your PC

If IP given here is not the intended one please change the IP again, the IP must be similar to RTU’sIP domain

Page 19: ABB

©C

opyr

ight

yea

r AB

B -

19-

Common Problem : Ping Test Once IP has been changed, type IPCONFIG again to test

Then proceed with ping test

Page 20: ABB

©C

opyr

ight

yea

r AB

B -

20-

Common Problem : Ping Test Type Ping 192.168.0.xx for self test

If the LAN card is okay you should have received reply as shown above

Page 21: ABB

©C

opyr

ight

yea

r AB

B -

21-

Common Problem : Ping Test Type Ping 192.168.0.xx for self test

If the LAN card is okay you should have received reply as shown above

Page 22: ABB

©C

opyr

ight

yea

r AB

B -

22-

Common Problem : Ping Test Type Ping 192.168.0.01 for RTU test

If the RTU connection is okay you should have received reply as shown above. Then you can proceed to launch the WEB Browser

Page 23: ABB

©C

opyr

ight

yea

r AB

B -

23-

Common Problem : Ping Test Type Ping 192.168.0.01 for RTU test

If the RTU connection is okay you should have received reply as shown above. Then you can proceed to launch the WEB Browser

Page 24: ABB

©C

opyr

ight

yea

r AB

B -

24-

Launching WEB BROWSER Type 192.168.0.1 in the address box

Page 25: ABB

©C

opyr

ight

yea

r AB

B -

25-

Launching WEB BROWSER Important Component

System Diagnosis

Hardware Tree

Archive Information

Configuration

Firmware

Administration

Other

Page 26: ABB

©C

opyr

ight

yea

r AB

B -

26-

Launching WEB BROWSER

If you first time using the WEB Browser you will be prompted with Authentication Box, Please key in your valid username and Password

Page 27: ABB

©C

opyr

ight

yea

r AB

B -

27-

WEB BROWSER: System Diagnosis

In here all information related to the system will be displayed

Page 28: ABB

©C

opyr

ight

yea

r AB

B -

28-

WEB BROWSER : Hardware tree

Identify slot number

Point and status

Time occurrence

Page 29: ABB

©C

opyr

ight

yea

r AB

B -

29-

WEB BROWSER : Archive Information

Archive function allow of historical data to be saved in RTU memory.

It could be retrieved whenever user like.

Function to save file into local drive

Page 30: ABB

©C

opyr

ight

yea

r AB

B -

30-

WEB BROWSER : Configuration

On this page, you can upload and download the configuration file

Page 31: ABB

©C

opyr

ight

yea

r AB

B -

31-

WEB BROWSER : Firmware

On this page, you can upload and download the firmware file

Page 32: ABB

©C

opyr

ight

yea

r AB

B -

32-

WEB BROWSER : Other

For some, due to incompatible java script you can use the old way to download configuration and firmware file

Page 33: ABB

©C

opyr

ight

yea

r AB

B -

33-

The End

Thank You for your attention