AB-RIO R-J2 fanuc Robot

Embed Size (px)

Citation preview

  • 8/21/2019 AB-RIO R-J2 fanuc Robot

    1/4

    Robo

    tics

    SYSTEM R-J2 ControllerNetworking Products

    FANUC Robotics provides arange of networking products

    supporting distributed I/O, remoteI/O and host communications.

    These products allow a centralnetwork to control and monitor the

    SYSTEM R-J2 Controller. TheR-J2 Controller networkingfeatures allow the central

    controller, either a ProgrammableLogic Controller (PLC) or a

    Personal Computer (PC), toperform cell level control functions

    of the R-J2 Controller and remotedevices. These functions include:cell status checks, variable

    manipulation and file transfers.

    Remote I/OCommunications

    The R-J2 Genius I/O Interfaceand the R-J2 A-B RIO Interfaceallow CNC and PLC controllers to

    remotely control I/O and obtainstatus information from the R-J2

    Controller.

    R-J2 Genius I/O Interface

    Basic Description

    The R-J2 Genius I/O Interfacemakes the R-J2 Controller look

    like a Genius I/O slave blocksupporting 128 inputs and 128outputs to GE FANUC PLCs. The

    Genius I/O Interface allowsaccess to the R-J2 Controller I/O

    including Digital, Group and UOP.

    R-J2 Genius I/O requires an ER-1style PCB supporting Genius I/Oand the Genius I/O Softpart. The

    ER-1 Genius I/O PCB connects tothe Genius I/O network via a

    twisted pair twin axial cable.

    Features and Benefits

    Allows communication with

    GE FANUC PLC series 6,series 90-30 and series 90-70

    Status communication of 128input and 128 output signals

    Allows direct control of R-J2

    Controller I/O by PLC withoutKAREL programming

    Compatible with Geniusnetwork devices such asseries 6 programmable

    controllers and IBM personalcomputers

    Significantly reduces number

    of components needed tointerface the R-J2 Controller

    to a Genius I/O network

    Reduces costs by eliminating

    the need for point-to-pointwiring of discrete I/O signals

    between the R-J2 Controllerand the programmable

    controller and provides 128I/O for interface

    Fewer electrical componentsand I/O interface wiring

    between the R-J2 Controllerand peripheral equipment

    improve system reliability

    Genius I/O Specifications

    Twisted Pair Twin Axial Cable(Belden 9463)

    Distance (feet) Baud Rate (Kbps)

    800 153.6 (std.)

    1,500 153.6 (extended)

    2,500 76.8

    3,500 38.4

    Ordering Information

    Description PCB Size Part Number

    R-J2 Genius I/O Int Full GBRJ-GENI

    R-J2 Genius I/O-MOTET Int Full GBRJ-MOTETGENI

    R-J2 Genius I/O-MOTET

    FTP, Controller Backup,

    Restore Full GBRJ-ETGENIFP

    Note 1: Available with Ethernet 10Base2 interface(Thinnet) as standard. 10Base5 and 10BaseTEthernet is optionally available.

    Full slot Genius Interface PCB

  • 8/21/2019 AB-RIO R-J2 fanuc Robot

    2/4

    A-B I/O Specifications

    Twisted Pair Serial Communication Cable(Belden 9463)

    Distance (feet) Baud Rate (Kbps)

    2,500 230.4

    5,000 115.2

    10,000 57.4

    Ordering Information

    Description PCB Size Part Number

    R-J2 A-B RIO Int Half GBRJ-ABRIO

    R-J2 A-B RIO/MOTET Int Half GBRJ-MOTETABRIO

    R-J2 A-B RIO/MOTET

    FTP, Controller Backup,

    Restore Full GBRJ-ETABRIOFTP

    Note 1: Available with Ethernet 10Base2 interface(Thinnet) as standard. 10Base5, 10BaseTEthernet is optionally available.

    R-J2 Allen-Bradley RIOInterface

    Basic Description

    The R-J2 A-B RIO Interfacemakes the R-J2 Controller looklike a slave rack of 128 inputs and

    128 outputs to A-B PLCs over anA-B 1771 Remote I/O network.The interface allows access to the

    R-J2 Controller I/O includingDigital, Group and UOP.

    R-J2 A-B RIO uses either anER-1 or ER-2 style PCB suppor-

    ting A-B RIO and the A-B RIOSoftpart. These connect to the

    A-B RIO network via a twistedpair twin axial cable.

    Features and Benefits

    Allows communication via1771 Remote I/O to A-B

    PLC-3 and PLC-5/30

    Status communication of 128

    input and 128 output signalsto an A-B PLC

    Allows control of R-J2

    Controller I/O by an A-B PLC

    Reduces the number ofcomponents needed tointerface the R-J2 Controller

    to an A-B PLC

    Eliminates the need for point-to-point wiring of discrete I/O

    signals between the R-J2Controller and the A-B PLC

    Provides increased flexibilityover discrete wiring to add

    signals/information commun-icated over the interface at

    little or no additional cost

    R-J2 MOTET Interface

    Basic Description

    The R-J2 MOTET Interface

    supports uploading anddownloading of user programs,

    data and system files for the R-J2Controller. System files includesystem variables, number and

    position registers and I/Oconfiguration data. The interface

    also allows direct access tosystem and data variables for

    robot control via Ethernet PCBs.

    The R-J2 MOTET Interface

    communicates with thePC/Windows MOTET Interface toaccess variables, backup and

    restore user programs, data andsystem files. The PC/Windows

    MOTET Interface is a Windows-based Application Program

    Interface (API) which can access

    FANUC R-J and R-J2 Controllers.

    MOTET (MMS on TCP/IPEthernet) is a FANUC Robotics

    proprietary protocol. MOTEThandles communication betweenthe R-J2 Controller and PC

    Windows MOTET Interface. Thisallows FANUC Robotics Works

    software packages to provideprogram storage and monitoring

    for the R-J2 Controller.

    Networking Products

    EthernetCommunicationOptions

    The R-J2 MOTET Interface andthe R-J2 ECBR-FTP Interface

    allow data and file transfercommunication between the R-J2Controller and a Host computer.

    Ethernet Software CommunicationOptions can be supported on

    10Base2 (Thinnet), 10Base5(Thicknet) or 10BaseT (Twisted

    Pair) to allow interconnect with allmajor forms of Ethernet. The

    10Base2 version is standard.

    Half slot combination AB-RIO/10Base2 PCB

  • 8/21/2019 AB-RIO R-J2 fanuc Robot

    3/4

    Features and Benefits

    Supports up to 16 simul-taneous connections, eight

    clients and eight servers.

    Offers a wide variety of hostconnections without requiringspecial RS-232 or RS-422port hardware

    Standard support for 10Base2

    (Thinnet) Ethernet allowsconnection of up to 29 hosts.

    Support for 10Base5(Thicknet) and 10BaseT

    (Twisted Pair) is also avail-able

    Allows upload and download

    of user program files. Enab-les quick updates to useroperational programs

    Provides access to program

    variables, which enablesmonitoring and control

    Directory services include filedirectory, delete and rename.

    File directory allows user tolist programs loaded into a

    controller

    Variable access services

    include read, write, errorreports and control

    Designed to communicate

    with Windows-based PCs viaPC/Windows MOTET

    Interface

    R-J2 ECBR-FTP

    The R-J2 ECBR-FTP Interface isa Host Communications feature

    which supports a variety of filetransfer capabilities between the

    R-J2 Controller and a HostComputer over an EthernetNetwork.

    The ECBR-FTP product includes

    support for the File Transfer

    Protocol (FTP) made popular withits useage over the Internet. The

    R-J2 FTP Interface supportsuploading and downloading of

    user programs, data and systemfiles to support user file mainten-

    ance and development of userprograms. Many of FTPs stan-dard features are implemented

    including: open, dir, get, put andclose.

    FTP is a part of the Ethernet

    Controller Backup/Restoreproduct which allows the entirerobot executive and user program

    image to be backed up to a hostcomputer as one or more large

    files. This image can be restoredto any robot controller. The imageis restored using the same

    BOOTP and TFTP protocolsdeveloped for use over the

    Internet.

    ECBR-FTP is interoperable with a

    MOTET Specifications

    Ordering Information

    Description PCB Size Part Number

    R-J2 MOTET Int Half GBRJ-MOTET

    R-J2 MOTET FTP,

    Controller Backup,

    Restore Half GBRJ-MOTETFTP

    Note 1: Available with Ethernet 10Base2 interface(Thinnet) as standard. 10Base5, 10BaseTEthernet is optionally available.

    wide variety of PC/DOS, PC/

    Windows, HP and Sun Unix, andother platforms. ECBR-FTP has

    been qualified on the followingplatforms:

    Distinct TCP/IP on MicrosoftWindows 3.11

    Hewlett-Packard Workstation

    HP-UX V9.01

    SUN Workstation SunOS

    V4.1.3

    Networking Products

    ECBR-FTP Specifications

    Ordering Information

    Description PCB Size Part Number

    R-J2 FTP,

    Controller Backup,

    Restore Half GBRJ-FTP

    Note 1: Available with Ethernet 10Base2 interface(Thinnet) as standard. 10Base5, 10BaseTEthernet is optionally available.

    Full slot combination AB-RIO/10BaseT PCB

  • 8/21/2019 AB-RIO R-J2 fanuc Robot

    4/4

    Distributed I/OCommunications

    FANUC Robotics R-J2 Model BI/O reduces wiring costs,

    facilitates long distance I/Oconnections (up to 100 meters)

    and easily expands the I/Osystem based on changing

    needs. Interfacing to cell devicesis simplified by the family of 120VAC and 24 VDC I/O units.

    R-J2 Model B I/O

    Basic Description

    FANUC Robotics R-J2 Model B

    I/O is designed to reduce the

    length and amount of I/O wiringbetween the R-J2 Controller andperipheral equipment. This

    system consists of a Model Binterface unit with four commun-ication channels that can connect

    up to 30 Model B DI/DO Units onthe R-J2 Controller. The max-

    imum number of I/O supportedover the 30 DI/DO Units is

    224/256 I/O.

    A DI/DO Unit consists of either a

    single I/O Base Unit or an I/OBase Unit with an attached I/OExtension Unit. One I/O

    Extension Unit can be connectedper I/O Base Unit to expand the

    total number of I/O per DI/DOUnit. The DI/DO Units are

    mounted near the peripherals tobe interfaced, reducing the wiringlength required.

    Communication along an I/O

    Channel between the Model B

    Interface Unit and DI/DO Units iscarried by a single twisted pair

    cable channel that is daisy-chained between DI/DO Units. A

    maximum of 15 DI/DO Units canbe placed on a single Model B I/O

    channel.

    Features and Benefits

    Remote mounting of I/O Units

    allows independentdevelopment of peripheral

    Model B I/O Specifications

    Ordering Information

    R-J2 Model B I/O Interface Part Number

    Operator Box Mounting Rail

    DIN Rail A05B-2350-J350

    i Cabinet Interface Module and Cable

    I/O-B BIF04A1 i-IntMod (30-512 I/O) A05B-2350-J300

    I/O-B Link Cable i-Int A05B-2350-J010

    B Cabinet Interface Module and Cable

    I/O-B BIF04A1 B-IntMod (30-512 I/O) A05B-2350-J301

    I/O-B Link Cable B-Int A05B-2350-J101

    I/O Base Units

    I/O-B BMD88A1 24VDC8DI/8DO Base A05B-2350-J310

    I/O-B BID16A1 24VDC

    16 DI Base A05B-2350-J311

    I/O-B BOD16A1 24VDC16 DO Base A05B-2350-J312

    I/O-B BOA12A1 240VAC12 DO Base A05B-2350-J313

    I/O Extension Units

    I/O-B BMD88P1 24VDC8DI/8DO Ext A05B-2350-J330

    I/O-B BID 16P1 24VDC16 DI Ext A05B-2350-J331

    I/O-B BOD16P1 24VDC16 DO Ext A05B-2350-J332

    I/O-B BIA16P1 120VAC16 DI Ext A05B-2350-J33

    Note 1: A separate Interface Module and I/O Link

    Cable is required depending on installation ineither the i-Cabinet or B-Cabinet.

    Note 2: R-J2 Model B I/O supports mounting of DI/DOUnits up to 100m from the Model B InterfaceUnit. Logic Power for the Model B I/O InterfaceUnit and Base Units must be supplied from theR-J2 Controller. The communications cableshould be Oki Electric Cable #2x20/0.18APEF40X-SVK or equivalent.

    equipment and reduces wiring

    cost between R-J2 andperipheral equipment

    The Model B Interface Unit

    communicates to the R-J2Controllers main CPU via theFANUC I/O Link. Model A

    (modular rack I/O) and ModelB I/O can be mixed on the

    R-J2 Controller for flexibilityin cell design

    A single twisted pair connec-tion between the R-J2 Con-

    troller and peripheral equip-ment increases system

    reliability

    DI/DO Units can be installedon DIN Rails (3.5mm wideand 7.5mm high) for fast

    installation and maintenance

    LED indication and errormessages provide fault

    diagnostics for the Model BInterface Unit and DI/DOUnits allowing quick DI/DO

    Unit diagnosis

    Several styles of DI/DO Unitsupport 24VDC I/O and 120

    VAC I/O in a mix of Base andExtended Units allow close

    application matches

    Networking Products

    FANUC Robotics North America Charlotte, NC Toronto, Canada3900 W. Hamlin Road Phone (704) 596-5121 Phone (905) 812-2300Rochester Hills, MI 48309-3253Phone (248) 377-7000 Chicago, IL Montral, QubecFax (248) 276-4133 Phone (847) 898-6000 Phone (450) 492-9001

    Literature Request Cincinnati, OH Mexico City, Mexico1-800-47-ROBOT Phone (513) 754-2400 Phone 52 (5) 611-5998

    Los Angeles, CA Aguascalientes, MexicoPhone (949) 595-2700 Phone 52 (49) 10-8000

    Toledo, OH Sao Paulo, BrazilPhone (419) 866-0788 Phone (55)(11) 3955-0599

    www.fanucrobotics.com

    1999 FANUC Robotics North America, Inc. All rights reserved. FANUC ROBOTICS LITHO IN U.S.A.FRNA-10/9-DS-046